🇨🇿 Ředitelství silnic a dálnic s. p. PL

ČIA 1072 • Brno - Chrlice, Czech Republic • 43 methods

Construction

Ředitelství silnic a dálnic s. p. is a laboratory accredited by ČIA under number 1072 (Brno - Chrlice, Czech Republic). Its accreditation scope covers 43 test methods in the following areas: Construction. Test objects include: Asphalt mixture, mastic asphalt, Concrete, Aggregate, Fresh concrete.

At a glance

  • Accreditation number: ČIA 1072
  • Methods in scope: 43
  • Types of test objects: 19
  • City: Brno - Chrlice, Czech Republic
  • Valid until: 31-08-2027
Accreditation number
1072
Accreditation body
ČIA
Address
Rebešovická 40, 643 00 Brno - Chrlice
City
Brno - Chrlice, Czech Republic
Division
Samodzielny Dział Badań Brno
Valid until
31-08-2027

What this laboratory tests (19)

Certificate information

Certificate date
22.05.2026

Accreditation scope — test methods (43)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Asphalt mixture, mastic asphalt Determination of soluble binder content, including sample preparation
Regulated area: Tests
ČSN EN 12697-1, čl. 5.1, 5.2.1, 5.2.2.1, 5.5.1, 5.5.2, 6, 7, 8; Laboratorní postup 509/18500/2020 (upřesnění přístroje podle ČSN EN 12697-1, čl. 5.1, poznámky 2); ČSN EN 12697-28, čl. 5.5
2 Asphalt mixture, mastic asphalt Determination of particle size distribution
Regulated area: Tests
ČSN EN 12697-2
3 Asphalt mixture, mastic asphalt Determination of maximum density, including sample preparation
Regulated area: Tests
ČSN EN 12697-5, mimo čl. 6.10, 9.3, 9.4, 10.3, 10.4; ČSN EN 12697-28, čl. 5.5
4 Asphalt mixture, mastic asphalt Determination of bulk density of bituminous specimen including sample preparation
Regulated area: Tests
ČSN EN 12697-6; ČSN EN 12697-30
5 Asphalt mixture, mastic asphalt Determination of indirect tensile strength
Regulated area: Tests
ČSN EN 12697-23
6 Asphalt mixture, mastic asphalt Determination of dimensions of bituminous specimens
Regulated area: Tests
ČSN EN 12697-29
7 Asphalt mixture, mastic asphalt, finished pavement Determination of asphalt layer thickness
Regulated area: Tests
ČSN EN 12697-36, mimo čl. 4.4, 6.2
8 Asphalt mixture, mastic asphalt, finished pavement Shear test of bond between layers
Regulated area: Tests
ČSN 73 6160, čl. 7.3
9 Asphalt mixture, mastic asphalt Determination of water sensitivity of specimens
Regulated area: Tests
ČSN EN 12697-12
10 Asphalt mixture, mastic asphalt Determination of air voids content
Regulated area: Tests
ČSN EN 12697-8, mimo čl. 5
11 Mastic asphalt Determination of indentation (hardness) number
Regulated area: Tests
ČSN EN 12697-20, mimo čl. 4.2.5, 4.2.6, 6.1, 6.5.2
12 Pavements, structural layers, trafficked surfaces, finished pavement Measurement of surface unevenness
Regulated area: Tests
ČSN 73 6175, čl. 8, 9
13 Hydraulically bound mixtures Determination of compressive strength
Regulated area: Tests
ČSN EN 13286-41
14 Hydraulically bound mixtures Determination of resistance to frost and water
Regulated area: Tests
ČSN 73 6124-1, příloha A
15 Concrete Determination of compressive strength
Regulated area: Tests
ČSN EN 12390-3
16 Concrete Determination of indirect tensile strength
Regulated area: Tests
ČSN EN 12390-6
17 Grouts, repair mortars Determination of compressive strength
Regulated area: Tests
ČSN EN 445, čl. 4.6; ČSN EN 12190
18 Concrete Determination of density
Regulated area: Tests
ČSN EN 12390-7, mimo čl. 6.5
19 Concrete, repair materials Determination of surface resistance to water and chemical de-icing agents
Regulated area: Tests
ČSN 73 1326, čl. 8 až 23
20 Mortar Determination of flexural and compressive strength
Regulated area: Tests
ČSN EN 1015-11
21 Concrete, concrete structures, precast elements Determination of compressive strength by Schmidt rebound hammer method
Regulated area: Tests
ČSN 73 1373, čl. 5.2, 5.4 až 6.2.2; ČSN EN 12504-2
22 Concrete Measurement of core length
Regulated area: Tests
ČSN EN 13863-3
23 Concrete Determination of depth of penetration of water under pressure
Regulated area: Tests
ČSN EN 12390-8
24 Concrete Determination of flexural tensile strength of test specimens
Regulated area: Tests
ČSN EN 12390-5
25 Concrete, mortars, repair materials, insulating layers Determination of adhesion of layers
Regulated area: Tests
ČSN 73 6242, příloha B, čl. B.3, B.4, B.5, B.6, B.7, tabulka B.1 a, c, d
26 Concrete, mortars, repair materials, insulating layers Determination of tensile strength of surface layers
Regulated area: Tests
ČSN 73 6242, příloha B, čl. B.3, B 4, B.5, B.6, B.7, tabulka B.1 b
27 Fresh concrete Slump test
Regulated area: Tests
ČSN EN 12350-2
28 Fresh concrete Determination of density
Regulated area: Tests
ČSN EN 12350-6
29 Fresh concrete Determination of air content – pressure methods
Regulated area: Tests
ČSN EN 12350-7, mimo čl. 5
30 Aggregate Determination of particle size distribution – sieving method
Regulated area: Tests
ČSN EN 933-1
31 Aggregate Determination of water content by drying in a ventilated oven
Regulated area: Tests
ČSN EN 1097-5
32 Aggregate Determination of particle shape – shape index
Regulated area: Tests
ČSN EN 933-4
33 Soils Determination of water content
Regulated area: Tests
ČSN EN ISO 17892-1
34 Soils Determination of bulk density with a membrane volumeter
Regulated area: Tests
ČSN 72 1010, čl. 35 až 44
35 Soils Determination of laboratory reference density and water content – Proctor test
Regulated area: Tests
ČSN EN 13286-2, mimo čl. 7.3, 7.6
36 Soils Determination of particle size distribution
Regulated area: Tests
ČSN EN ISO 17892-4, čl. 5.1, 5.2
37 Soils, bulk materials and base courses Static plate load test
Regulated area: Tests
ČSN 72 1006, příloha A
38 Asphalt mixture, reclaimed asphalt and other materials containing bitumen Determination of PAH by GC/MS and of their sum by calculation from the measured values
naphthalene anthracene fluoranthene pyrene benzo(a)anthracene chrysene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene indeno(1,2,3-cd)pyrene dibenz(a,h)anthracene benzo(ghi)perylene
sum of PAH (calculated)
Regulated area: Tests
Laboratorní postup 1/18500/2023 (ČSN EN 17503)
39 Soils, unbound mixtures Determination of California bearing ratio, immediate bearing index (CBR/IBI) and linear swelling
Regulated area: Tests
ČSN EN 13286-47
40 Fresh concrete Sampling of fresh concrete
Regulated area: Sampling
ČSN EN 12350-1
41 Aggregate Sampling of aggregate; methods for reducing laboratory samples
Regulated area: Sampling
ČSN EN 932-1; ČSN EN 932-2
42 Hardened concrete Sampling of hardened concrete (cores from structures)
Regulated area: Sampling
ČSN EN 12504-1, čl. 4 až 6
43 Asphalt mixture, asphalt layer Sampling of asphalt mixture
Regulated area: Sampling
ČSN EN 12697-27, čl. 4.1, 4.2, 4.3, 4.4, 4.7

Reference standards (49)

Laboratorní postup 1/18500/2023
Laboratorní postup 509/18500/2020
ČSN 72 1006
ČSN 72 1010
ČSN 73 1326
ČSN 73 1373
ČSN 73 6124-1
ČSN 73 6160
ČSN 73 6175
ČSN 73 6242
ČSN EN 1015-11
ČSN EN 1097-5
ČSN EN 12190
ČSN EN 12350-1
ČSN EN 12350-2
ČSN EN 12350-6
ČSN EN 12350-7
ČSN EN 12390-3
ČSN EN 12390-5
ČSN EN 12390-6
ČSN EN 12390-7
ČSN EN 12390-8
ČSN EN 12504-1
ČSN EN 12504-2
ČSN EN 12697-1
ČSN EN 12697-12
ČSN EN 12697-2
ČSN EN 12697-20
ČSN EN 12697-23
ČSN EN 12697-27
ČSN EN 12697-28
ČSN EN 12697-29
ČSN EN 12697-30
ČSN EN 12697-36
ČSN EN 12697-5
ČSN EN 12697-6
ČSN EN 12697-8
ČSN EN 13286-2
ČSN EN 13286-41
ČSN EN 13286-47
ČSN EN 13863-3
ČSN EN 17503
ČSN EN 445
ČSN EN 932-1
ČSN EN 932-2
ČSN EN 933-1
ČSN EN 933-4
ČSN EN ISO 17892-1
ČSN EN ISO 17892-4

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1072