🇨🇿 ORLEN Unipetrol RPA s.r.o. PL

ČIA 1050.2 • Litvínov, Czech Republic • 19 methods

Water & wastewaterEnvironment

ORLEN Unipetrol RPA s.r.o. is a laboratory accredited by ČIA under number 1050.2 (Litvínov, Czech Republic). Its accreditation scope covers 19 test methods in the following areas: Water & wastewater, Environment. Test objects include: Surface water and waste water, Workplace air, Waste water, Drinking water, surface water and waste water.

At a glance

  • Accreditation number: ČIA 1050.2
  • Methods in scope: 19
  • Types of test objects: 5
  • City: Litvínov, Czech Republic
  • Valid until: 05-12-2029
Accreditation number
1050.2
Accreditation body
ČIA
Address
DS:166, Litvínov – Záluží 1, 436 70
City
Litvínov, Czech Republic
Division
Laboratorium Agro i Wód
Valid until
05-12-2029

What this laboratory tests (5)

Laboratory sections (2)

Laboratory locations

Certificate information

Certificate date
04.06.2026

Accreditation scope — test methods (19)

No. Test object Methodology / Parameters Technique Reference document
Occupational Hygiene Laboratory
1 Working environment Noise measurement
Regulated area: Tests
PRP – LHP – 08 (ČSN EN ISO 9612; Věstník MZ ČR 2013, částka 4, část 4)
2 Workplace air Determination of concentration of total and respirable fractions of airborne dust by gravimetry
Regulated area: Tests
LP – LHP – 01 mimo čl. 5.2.1 – 5.2.4, 5.4 (ČSN EN 481; Nařízení vlády č. 361/2007 Sb.)
3 Workplace air Determination of hydrocarbons (benzene, toluene, ethylbenzene, xylenes) by GC/FID
benzene toluene ethylbenzene xylenes
Regulated area: Tests
LP – LHP – 02 (ČSN EN 689+AC; ČSN EN 482; Nařízení vlády č. 361/2007 Sb.)
4 Surface water and waste water Determination of adsorbable organically bound halogens (AOX) by microcoulometry
Regulated area: Tests
LP – LHP – 04 (ČSN EN ISO 9562)
5 Workplace air Sampling of gases and vapours onto a solid sorbent
Regulated area: Sampling
PRP – LHP – 11 (ČSN EN 689+AC; ČSN EN 482; Nařízení vlády č. 361/2007 Sb.)
6 Workplace air Sampling of total and respirable fractions of airborne dust
Regulated area: Sampling
LP – LHP – 01 čl. 5.2.1 – 5.2.4, 5.4 (ČSN EN 481; Nařízení vlády č. 361/2007 Sb.)
Waste Water Laboratory
7 Surface water and waste water Determination of dissolved solids dried (RL105) and ignited (RAS) by gravimetry
Regulated area: Tests
LP – LOV – 8 (ČSN 75 7346; ČSN 75 7347)
8 Surface water and waste water Determination of suspended solids (NL) by gravimetry
Regulated area: Tests
LP – LOV – 6 (ČSN EN 872)
9 Waste water Determination of ammonium nitrogen by titrimetry
Regulated area: Tests
LP – LOV – 3 (ČSN ISO 5664)
10 Drinking water, surface water and waste water Determination of pH by potentiometry
Regulated area: Tests
LP – LOV – 11 (ČSN ISO 10523)
11 Surface water and waste water Determination of biochemical oxygen demand (BOD5) by electrochemical method
Regulated area: Tests
LP – LOV – 4 (ČSN EN ISO 5815-1; ČSN EN 1899-2)
12 Surface water and waste water Determination of total nitrogen with a TOC analyser with electrochemical detection
Regulated area: Tests
LP – LOV – 113 (ČSN EN ISO 20236)
13 Waste water Determination of total phosphorus by spectrophotometry
Regulated area: Tests
LP – LOV – 5 (ČSN EN ISO 6878, kap. 7)
14 Surface water and waste water Determination of chemical oxygen demand by potassium dichromate (CODCr) by spectrophotometry with a HACH cuvette test
Regulated area: Tests
LP – LOV – 34 (ČSN ISO 15705; návod firmy Hach)
15 Waste water Determination of monohydric phenols by spectrophotometry
Regulated area: Tests
LP – LOV – 27 (ČSN ISO 6439)
16 Surface water and waste water Determination of hydrocarbons C10 to C40 by GC/FID
Regulated area: Tests
LP – LOV – 151 (ČSN EN ISO 9377-2)
17 Surface water and waste water Determination of total cyanides by titrimetry
Regulated area: Tests
LP – LOV – 7 (ČSN 75 7415)
18 Surface water and waste water Determination of nitrate and nitrite by IC/CD and calculation of nitrate and nitrite nitrogen from the measured values
nitrate nitrite
nitrate and nitrite nitrogen (calculated)
Regulated area: Tests
LP – LOV – 114 (ČSN EN ISO 10304-1)
19 Surface water and waste water Determination of As, Cd, Cr, Cu, Ni, Pb, V, Zn, Hg by ICP/OES
arsenic (As) cadmium (Cd) chromium (Cr) copper (Cu) nickel (Ni) lead (Pb) vanadium (V) zinc (Zn) mercury (Hg)
Regulated area: Tests
LP – LOV – 41 (ČSN EN ISO 11885; Instrukce firmy Agilent; Aplikační list firmy Agilent)

Reference standards (43)

Aplikační list firmy Agilent
Instrukce firmy Agilent
LP – LHP – 01
LP – LHP – 02
LP – LHP – 04
LP – LOV – 11
LP – LOV – 113
LP – LOV – 114
LP – LOV – 151
LP – LOV – 27
LP – LOV – 3
LP – LOV – 34
LP – LOV – 4
LP – LOV – 41
LP – LOV – 5
LP – LOV – 6
LP – LOV – 7
LP – LOV – 8
Nařízení vlády č. 361/2007 Sb.
PRP – LHP – 08
PRP – LHP – 11
Věstník MZ ČR 2013, částka 4, část 4
návod firmy Hach
ČSN 75 7346
ČSN 75 7347
ČSN 75 7415
ČSN EN 1899-2
ČSN EN 481
ČSN EN 482
ČSN EN 689+AC
ČSN EN 872
ČSN EN ISO 10304-1
ČSN EN ISO 11885
ČSN EN ISO 20236
ČSN EN ISO 5815-1
ČSN EN ISO 6878, kap. 7
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9612
ČSN ISO 10523
ČSN ISO 15705
ČSN ISO 5664
ČSN ISO 6439

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1050.2