⚡ Tensile strength and elongation at break of cable insulation and sheaths (crosslinked and thermoplastic compounds) — dumb-bell test pieces 0,8 mm to 2,0 mm thick after grinding or cutting (PE and PP cutting only) or tubular test pieces, conditioning for at least 3 h at 23 °C, cross-section from width and thickness or from dimensions, density or volume; PN-EN 60811-501
In short
The tensile strength and elongation at break of cable insulating and sheathing material are determined on dumb-bell test pieces cut from insulation removed from the core (after grinding or cutting to a thickness of 0,8 mm to 2,0 mm) or — when the core is too thin — on tubular test pieces, in the condition as manufactured and after the ageing required by the cable standard. The test is performed according to PN-EN 60811-501:2012 (Polish version; implements EN 60811-501:2012 and IEC 60811-501:2012 [IDT]) with amendments PN-EN 60811-501:2012/A1:2019-01 (Polish version; implements EN 60811-501:2012/A1:2018 and IEC 60811-501:2012/AMD1:2018 [IDT]) and PN-EN 60811-501:2012/A2:2024-03 (English version; implements EN 60811-501:2012/A2:2023 and IEC 60811-501:2012/AMD2:2023 [IDT]); STATUS (as of 22.11.2026): PKN cards: PN-EN 60811-501:2012 (Polish version, published 05-12-2022, 20 pages, KT 53, implements EN 60811-501:2012 and IEC 60811-501:2012 [IDT]) with amendments A1:2019-01 (Polish version; changes 4.2.1 and 4.2.3, deletes 4.2.5 and 4.3.5) and A2:2024-03 (English version; changes 4.2.1, 4.2.4 and 4.3.1); the cards give no withdrawal date. The procedure comprises 5 steps (about 3 h in total); it is used for: Crosslinked and thermoplastic insulating and sheathing compounds of cables (clause 1), Test in the condition as manufactured and after accelerated ageing required by the cable standard, e.g. in an air oven according to IEC 60811-401 (4.2.1), Cores of small diameter — small dumb-bell (Figure 2) or tubular test pieces (4.2.3 b, c).
At a glance
- Standard: PN-EN 60811-501:2012 (Polish version; implements EN 60811-501:2012 and IEC 60811-501:2012 [IDT]) with amendments PN-EN 60811-501:2012/A1:2019-01 (Polish version; implements EN 60811-501:2012/A1:2018 and IEC 60811-501:2012/AMD1:2018 [IDT]) and PN-EN 60811-501:2012/A2:2024-03 (English version; implements EN 60811-501:2012/A2:2023 and IEC 60811-501:2012/AMD2:2023 [IDT])
- Category: Electronics and EMC
- Procedure steps: 5
- Total time of stages: 3 h
- STATUS (as of 22.11.2026): PKN cards: PN-EN 60811-501:2012 (Polish version, published 05-12-2022, 20 pages, KT 53, implements EN 60811-501:2012 and IEC 60811-501:2012 [IDT]) with amendments A1:2019-01 (Polish version; changes 4.2.1 and 4.2.3, deletes 4.2.5 and 4.3.5) and A2:2024-03 (English version; changes 4.2.1, 4.2.4 and 4.3.1); the cards give no withdrawal date.
- Conditioning (4.1, 4.2.3 a): at least 3 h at (23 ± 5) °C; thermoplastic insulation (23 ± 2) °C; at elevated temperature, when required: 24 h at (70 ± 2) °C or lower (wording of edition 1.0 — clause changed by A1:2018, we have not read the text after the amendment)
- Number of test pieces (4.2.2): at least 5 for the test without ageing and for each ageing; 100 mm per test piece
Overview
WHAT THE STANDARD COVERS. According to clause 1 of IEC 60811-501:2012 the standard gives the procedure for determining the mechanical properties, which typically applies to crosslinked and thermoplastic compounds used for insulating and sheathing materials. The tests determine the tensile strength and elongation at break of the insulating material (excluding any semi-conducting layers) in the condition as manufactured, without ageing, and — when required by the cable product standard — after one or more accelerated ageing treatments. Definitions (3.1–3.4): maximum tensile force, tensile stress (force per unit cross-section of the unstretched test piece), tensile strength (maximum stress up to breaking) and elongation at break (increase of the distance between the reference marks as a percentage of the initial distance).
ACCORDING TO THE TEXT OF IEC 60811-501:2012 (edition 1.0, 2012-03; publisher's sample: clauses 1–3 and subclauses 4.1–4.2.4). The standard was prepared by IEC TC 20; Part 501 replaces Clause 9 of IEC 60811-1-1:1993, and the only significant technical change with respect to the previous edition concerns the requirements for the (minimum) thickness of dumb-bell test pieces. It is used in conjunction with IEC 60811-100:2012. It applies with amendments AMD1:2018 and AMD2:2023 (consolidated version IEC 60811-501:2012+AMD1:2018+AMD2:2023 CSV, edition 1.2) — we have not read their content (the preview of the consolidated version ends at clause 3), so the description below reflects the text of edition 1.0.
TEST PIECES AND CONDITIONING (4.1–4.2.3). Unless otherwise specified, all test pieces — aged and unaged — are kept before the test for at least 3 h at (23 ± 5) °C. From each core to be tested a sample is taken sufficient for at least five test pieces for the test without ageing and after each required ageing (100 mm is needed for each test piece); the cores of unsheathed flat cables are not separated, and samples with mechanical damage are not used. Test pieces for ageing are taken adjacent to the test pieces without ageing, and the tensile tests on both are made in immediate succession. Conditioning at elevated temperature (not an ageing treatment) is used when required by the cable standard or when a test is repeated in case of doubt — then 24 h at (70 ± 2) °C or at a lower temperature corresponding to the maximum operating temperature of the conductor. Before the cross-section is determined, the test pieces are protected from direct sunlight and kept for at least 3 h at (23 ± 5) °C, and thermoplastic insulation at (23 ± 2) °C.
DUMB-BELLS AND TUBES (4.2.3 b, c). Dumb-bells are used whenever possible: the insulation is cut open along the axis of the core, semi-conducting layers are removed mechanically (without solvent), and the strips are ground or cut to obtain two parallel smooth surfaces (PE and PP insulation — cutting only), avoiding undue heating. Strip thickness after preparation: from 0,8 mm to 2,0 mm; if 0,8 mm cannot be achieved, tubular test pieces are used, and if this is impossible too — thinner dumb-bells with a rate of separation of 25 mm/min and a note in the test report that the result is indicative. A dumb-bell according to Figure 1 (or the smaller one according to Figure 2 for thin cores) is punched with a sharp punch; the central 20 mm (10 mm for the small dumb-bell) are marked immediately before the test. Tubes (about 100 mm) are used only when a dumb-bell cannot be prepared; pieces of separator becoming visible during stretching lead to rejection of the result.
CROSS-SECTION (4.2.4). Dumb-bell: common width = minimum width of three randomly selected test pieces, thickness of each test piece = minimum of three measurements in the area to be stretched; optical instrument or dial gauge with a contact pressure not exceeding 0,07 N/mm² (in case of doubt an optical instrument or a dial gauge with a maximum pressure of 0,02 N/mm²), measuring error not more than 0,01 mm for thickness and 0,04 mm for width. Tube: b1) A = π (D − δ) δ from the insulation thickness (IEC 60811-201) and the diameter (IEC 60811-203); b2) A = 1 000 m / (d × l) from the mass, density (IEC 60811-606) and length — the decisive method in case of doubt; b3) A = V / l from the volume determined by immersion, e.g. in ethyl alcohol.
WHAT WE DO NOT GIVE HERE. We do not reproduce the tensile test itself (4.2.6: rate of separation of the grips, number of valid results), the calculation of results (4.2.7), the test on sheaths (4.3) or the changes of AMD1:2018 and AMD2:2023, because they are not in the texts we read; nor do we give the dimensions of the dumb-bells from Figures 1 and 2.
STATUS (as of 22.11.2026). PKN cards: PN-EN 60811-501:2012 “Kable i przewody elektryczne oraz światłowodowe -- Metody badań materiałów niemetalowych -- Część 501: Badania mechaniczne -- Sprawdzenie właściwości mechanicznych mieszanek izolacyjnych i powłokowych” — Polish version, published 05-12-2022, 20 pages, KT 53 (cables and wires), implements EN 60811-501:2012 [IDT] and IEC 60811-501:2012 [IDT], replaces PN-EN 60811-1-1:1999 and PN-EN 60811-1-1:1999/A1:2002 (Polish versions); PN-EN 60811-501:2012/A1:2019-01 — Polish version, published 27-12-2022, 5 pages, changes 4.2.1 and 4.2.3 (preparation and conditioning of test pieces), deletes 4.2.5 and 4.3.5 (ageing treatment); PN-EN 60811-501:2012/A2:2024-03 — English version, published 08-03-2024, 12 pages, changes 4.2.1, 4.2.4 (cross-section) and 4.3.1. Neither card gives a withdrawal date. The description of clauses 4.2.1, 4.2.3 and 4.2.4 above therefore reflects the wording before these amendments.
Method principle
Dumb-bells (after grinding or cutting to a uniform thickness) or tubes are prepared from the insulation or sheath of the cable, conditioned, their cross-section is determined and they are then stretched to breaking; tensile strength and elongation at break are determined in the condition as manufactured and after ageing.
Applications
- Crosslinked and thermoplastic insulating and sheathing compounds of cables (clause 1)
- Test in the condition as manufactured and after accelerated ageing required by the cable standard, e.g. in an air oven according to IEC 60811-401 (4.2.1)
- Cores of small diameter — small dumb-bell (Figure 2) or tubular test pieces (4.2.3 b, c)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 22.11.2026) | PKN cards: PN-EN 60811-501:2012 (Polish version, published 05-12-2022, 20 pages, KT 53, implements EN 60811-501:2012 and IEC 60811-501:2012 [IDT]) with amendments A1:2019-01 (Polish version; changes 4.2.1 and 4.2.3, deletes 4.2.5 and 4.3.5) and A2:2024-03 (English version; changes 4.2.1, 4.2.4 and 4.3.1); the cards give no withdrawal date. |
| Conditioning (4.1, 4.2.3 a) | at least 3 h at (23 ± 5) °C; thermoplastic insulation (23 ± 2) °C; at elevated temperature, when required: 24 h at (70 ± 2) °C or lower (wording of edition 1.0 — clause changed by A1:2018, we have not read the text after the amendment) |
| Number of test pieces (4.2.2) | at least 5 for the test without ageing and for each ageing; 100 mm per test piece |
| Dumb-bell thickness (4.2.3 b) | 0,8 mm to 2,0 mm after grinding or cutting (PE and PP cutting only); thinner — rate 25 mm/min, indicative result (wording of edition 1.0 — clause changed by A1:2018, we have not read the text after the amendment) |
| Gauge length (4.2.3 b, c) | central 20 mm (small dumb-bell 10 mm), marked immediately before the test (wording of edition 1.0 — clause changed by A1:2018, we have not read the text after the amendment) |
| Measurement of thickness and width (4.2.4 a) | thickness error ≤ 0,01 mm, width error ≤ 0,04 mm; dial gauge pressure ≤ 0,07 N/mm² (in case of doubt an optical instrument or ≤ 0,02 N/mm²) (wording of edition 1.0 — clause changed by A2:2023, we have not read the text after the amendment) |
| Cross-section of a tube (4.2.4 b) | A = π (D − δ) δ; A = 1 000 m / (d × l) — decisive; A = V / l (wording of edition 1.0 — clause changed by A2:2023, we have not read the text after the amendment) |
Standard
- Standard number
- PN-EN 60811-501:2012 (Polish version; implements EN 60811-501:2012 and IEC 60811-501:2012 [IDT]) with amendments PN-EN 60811-501:2012/A1:2019-01 (Polish version; implements EN 60811-501:2012/A1:2018 and IEC 60811-501:2012/AMD1:2018 [IDT]) and PN-EN 60811-501:2012/A2:2024-03 (English version; implements EN 60811-501:2012/A2:2023 and IEC 60811-501:2012/AMD2:2023 [IDT])
- Title (PL)
- Kable i przewody elektryczne oraz światłowodowe — Metody badań materiałów niemetalowych — Część 501: Badania mechaniczne — Sprawdzenie właściwości mechanicznych mieszanek izolacyjnych i powłokowych
- Title (EN)
- Electric and optical fibre cables — Test methods for non-metallic materials — Part 501: Mechanical tests — Tests for determining the mechanical properties of insulating and sheathing compounds
Step-by-step procedure
-
Sampling
Sample from each core for at least 5 test pieces for the test without ageing and after each ageing, 100 mm per test piece; without mechanical damage (4.2.2).
-
Dumb-bells
Cutting the insulation open along the axis, mechanical removal of semi-conducting layers, grinding or cutting to 0,8 mm to 2,0 mm (PE and PP cutting only), punching and marking the central 20 mm (10 mm) (4.2.3 b).
-
Tubes
Only when a dumb-bell cannot be prepared: pieces of about 100 mm, removal of the conductor and separator without damaging the insulation, marking the central 20 mm (4.2.3 c).
-
Conditioning
Protection from sunlight, at least 3 h at (23 ± 5) °C — thermoplastic insulation (23 ± 2) °C (4.2.3 a).
-
Cross-section
Dumb-bell — common width and minimum thickness of each test piece; tube — from the dimensions, from the mass and density or from the volume (4.2.4).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Machine for grinding or cutting strips (4.2.3 b, Annex A) | Obtaining two parallel smooth surfaces without undue heating; example of a machine in Annex A | — |
| Dumb-bell punch (4.2.3 b) | Very sharp; for materials producing burrs — with a groove of about 2,5 mm × 2,5 mm at each end (Figure 3) | — |
| Optical instrument or dial gauge (4.2.4 a) | Thickness error ≤ 0,01 mm, width error ≤ 0,04 mm; pressure ≤ 0,07 N/mm² (≤ 0,02 N/mm² in case of doubt) | — |
Reagents, media and consumables
| Reagent | CAS | Details |
|---|---|---|
| Ethyl alcohol (4.2.3 c, 4.2.4 b3) | — | Immersion when removing polyethylene terephthalate separators and as the liquid for determining the volume of a tubular test piece |
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN 60811-501:2012 (Polish version; implements EN 60811-501:2012 and IEC 60811-501:2012 [IDT]) with amendments PN-EN 60811-501:2012/A1:2019-01 (Polish version; implements EN 60811-501:2012/A1:2018 and IEC 60811-501:2012/AMD1:2018 [IDT]) and PN-EN 60811-501:2012/A2:2024-03 (English version; implements EN 60811-501:2012/A2:2023 and IEC 60811-501:2012/AMD2:2023 [IDT]) — “Electric and optical fibre cables — Test methods for non-metallic materials — Part 501: Mechanical tests — Tests for determining the mechanical properties of insulating and sheathing compounds”.
How does this method work?
Dumb-bells (after grinding or cutting to a uniform thickness) or tubes are prepared from the insulation or sheath of the cable, conditioned, their cross-section is determined and they are then stretched to breaking; tensile strength and elongation at break are determined in the condition as manufactured and after ageing.
What is the measuring range and accuracy?
STATUS (as of 22.11.2026): PKN cards: PN-EN 60811-501:2012 (Polish version, published 05-12-2022, 20 pages, KT 53, implements EN 60811-501:2012 and IEC 60811-501:2012 [IDT]) with amendments A1:2019-01 (Polish version; changes 4.2.1 and 4.2.3, deletes 4.2.5 and 4.3.5) and A2:2024-03 (English version; changes 4.2.1, 4.2.4 and 4.3.1); the cards give no withdrawal date.; Conditioning (4.1, 4.2.3 a): at least 3 h at (23 ± 5) °C; thermoplastic insulation (23 ± 2) °C; at elevated temperature, when required: 24 h at (70 ± 2) °C or lower (wording of edition 1.0 — clause changed by A1:2018, we have not read the text after the amendment); Number of test pieces (4.2.2): at least 5 for the test without ageing and for each ageing; 100 mm per test piece; Dumb-bell thickness (4.2.3 b): 0,8 mm to 2,0 mm after grinding or cutting (PE and PP cutting only); thinner — rate 25 mm/min, indicative result (wording of edition 1.0 — clause changed by A1:2018, we have not read the text after the amendment).
How long does the test take?
The times given for the individual stages add up to approximately 3 h. The procedure comprises 5 steps.
What equipment is required?
Machine for grinding or cutting strips (4.2.3 b, Annex A), Dumb-bell punch (4.2.3 b), Optical instrument or dial gauge (4.2.4 a).
Where is this test used?
Crosslinked and thermoplastic insulating and sheathing compounds of cables (clause 1); Test in the condition as manufactured and after accelerated ageing required by the cable standard, e.g. in an air oven according to IEC 60811-401 (4.2.1); Cores of small diameter — small dumb-bell (Figure 2) or tubular test pieces (4.2.3 b, c).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 60811-501.