🏗️ Thermal insulating products for building applications — determination of the length and width of a full-size product: metal rule or tape read to 0,5 mm on a flat surface, conditioning ≥ 6 h at (23 ± 5) °C, additional measurements per metre above 1,5 m, result — mean to the nearest 1 mm (length ≥ 3 m — to 5 mm); PN-EN 822 (withdrawn, replaced by PN-EN ISO 29465)
In short
Determination of the length and width of full-size thermal insulating products for building applications (boards, mats, rolls). The test is performed according to PN-EN 822:2013-07 (English version; implements EN 822:2013 [IDT]) — withdrawn 02-03-2023, replaced by PN-EN ISO 29465:2023-03; STATUS (PKN card as of 13.11.2026): PN-EN 822:2013-07 (English version) withdrawn 02-03-2023; replaced by PN-EN ISO 29465:2023-03; implemented EN 822:2013. The procedure comprises 5 steps; it is used for: Thermal insulating products for building applications — full-size products (EN 822:2013, clause 1), A standard from the group of CEN/TC 88 test methods supporting standards for thermal insulating products (foreword), Also outside building, where applicable (foreword).
At a glance
- Standard: PN-EN 822:2013-07 (English version; implements EN 822:2013 [IDT]) — withdrawn 02-03-2023, replaced by PN-EN ISO 29465:2023-03
- Category: Construction
- Procedure steps: 5
- STATUS (PKN card as of 13.11.2026): PN-EN 822:2013-07 (English version) withdrawn 02-03-2023; replaced by PN-EN ISO 29465:2023-03; implemented EN 822:2013
- Instrument (5.2): metal rule or tape graduated in millimetres, reading to 0,5 mm; flat surface (5.1)
- Specimen (6.1–6.2): full-size product; number according to the product standard or agreement between the parties
Overview
WHAT THE STANDARD COVERS. According to clause 1 of EN 822:2013 the standard specifies the equipment and procedures for determining the length and width of full-size products and applies to thermal insulating products. According to the foreword it is one of a group of CEN/TC 88 standards on test methods for the dimensions and properties of thermal insulating products (alongside, among others, EN 823 — thickness, EN 824 — squareness, EN 825 — flatness, EN 12085 — dimensions of test specimens), supporting product standards issued under Directive 89/106/EEC; prepared for building applications, it may also be used in other fields. The 2013 edition replaced EN 822:1994 without significant changes (editorial corrections). The standard has no normative references.
ACCORDING TO THE TEXT OF EN 822:2013 — DEFINITIONS, PRINCIPLE, APPARATUS, SPECIMENS, PROCEDURE, RESULT (foreword, clauses 1–9, beginning of clause 10). Definitions (clause 3): length l — the longer linear dimension of the major face of the specimen; width b — the shorter linear dimension of the major face, measured perpendicular to the length. Principle (clause 4): the specimen is laid on a flat surface and measured directly with a metal rule or tape. Apparatus (clause 5): flat surface; metal rule or tape graduated in millimetres, allowing reading to 0,5 mm; other equipment giving the same result with at least the same accuracy is allowed. Specimens (clause 6): the specimen is the full-size product; number according to the product standard or, in its absence, as agreed between the parties; storage for at least 6 h at (23 ± 5) °C, in case of dispute at (23 ± 2) °C and (50 ± 5) % relative humidity for the time stated in the product standard. Procedure (clause 7): test at (23 ± 5) °C (in case of dispute (23 ± 2) °C and (50 ± 5) %); the specimen is laid carefully on the flat surface; when both dimensions are ≤ 1,5 m — one measurement of length and one of width at the positions of Figure 1; for a length over 1,5 m — an additional width measurement for each further metre of length, at most five measurements, equally spaced (Figure 2); for a width over 1,5 m — an additional length measurement for each further metre of width, equally spaced; readings to the nearest millimetre. Result (clause 8): length and width in millimetres to the nearest 1 mm as the mean for each specimen; the length of products 3 m long and longer is rounded to 5 mm. Accuracy (clause 9): the edition gives no estimate of the accuracy of the method. Test report (clause 10): reference to the standard, product identification (name, factory, manufacturer or supplier, production code, type, packaging, form on arrival, other information, e.g. nominal thickness, nominal density), history before testing and sampling.
STATUS (PKN card as of 13.11.2026). The card for PN-EN 822:2013-07 (English version): "Withdrawn and replaced by" PN-EN ISO 29465:2023-03 (English version), withdrawal date 02-03-2023; title "Wyroby do izolacji cieplnej w budownictwie -- Określanie długości i szerokości", published 30-07-2013, 10 pages, KT 211 for Thermal Insulating Products for Building Applications, "Implements: EN 822:2013 [IDT]", "Replaces: PN-EN 822:1998 - Polish version", ICS 91.100.60. In the iTeh catalogue SIST EN 822:2013 — withdrawn 26-09-2022, replaced by SIST EN ISO 29465:2022.
HOW MANY LABORATORIES AND IN WHAT FORM (accreditation scope database of the service, read 13.11.2026). The notation EN 822 appears in 5 records at 4 Polish laboratories: "PN-EN 822:2013-07" — AB 011 and AB 023 (two records, one together with PN-EN 12085:2013-07); "PN-EN 822" without a date — AB 008 and AB 054, both together with PN-EN ISO 29465. According to the scope of AB 023 (edition 32 of 12.10.2026) the mark "N" next to the standard (AB 008, AB 023) denotes a method used in activities relevant to notification under Regulation (EU) No 305/2011, and the asterisk — tests on the basis of which the laboratory formulates opinions and interpretations. Outside Poland — 4 Czech laboratories (ČSN EN 822:2013, usually alongside ČSN EN ISO 29465).
WHAT THE LABORATORIES TEST (scope database, complete items — 4 Polish). Thermal insulating products for buildings and for building equipment and industrial installations — length and width, range (1–20000) mm (AB 008); thermal insulating products for building applications — length and width (AB 011); thermal insulating materials — dimensions (length, width), range up to 2000 mm (AB 054); thermal insulating materials and products — products of expanded cork (IC), expanded perlite (EP), phenolic foam (PF), XPS, wood wool (WW), mineral wool (MW), wood fibre (WF), expanded polystyrene (EPS), cellular glass (CG), PUR/PIR — length and width, linear geometric dimensions (AB 023).
WHERE AN APPARENTLY CORRECT RESULT IS EASY TO GET. Specimen: a cut piece instead of the full-size product; storage of ≥ 6 h at (23 ± 5) °C omitted. Measurement: too few measurements on products over 1,5 m (an additional one for each metre; width — at most five measurements), measurements unevenly spaced; rule not readable to 0,5 mm. Result: a single reading instead of the mean; length of a product ≥ 3 m not rounded to 5 mm. Status: reference to the withdrawn standard without stating that it was replaced by PN-EN ISO 29465:2023-03.
WHAT WE DO NOT GIVE. Part read: the iTeh sample of SIST EN 822:2013 (English version) — foreword, clauses 1–9 and the beginning of clause 10 (up to the item on the history of the specimen before testing). We do not reproduce Figures 1 and 2 — we give only their titles and the arrangement of measurements described in the text. We did not examine the differences between EN 822:2013 and EN ISO 29465 which replaced it.
Method principle
A full-size thermal insulating product, stored for at least 6 h at (23 ± 5) °C, is laid carefully on a flat surface and measured directly with a metal rule or tape graduated in millimetres (reading to 0,5 mm): for dimensions up to 1,5 m — one measurement of length and one of width, for larger ones — an additional measurement for each further metre, equally spaced (width at most five times). The result is the mean for the specimen in millimetres to the nearest 1 mm; the length of products of 3 m and more is rounded to 5 mm.
Applications
- Thermal insulating products for building applications — full-size products (EN 822:2013, clause 1)
- A standard from the group of CEN/TC 88 test methods supporting standards for thermal insulating products (foreword)
- Also outside building, where applicable (foreword)
- In accreditation scopes: 4 Polish laboratories — EPS, XPS, MW, PUR/PIR, PF, CG, WF, WW and other products; 4 Czech
Key parameters
| Parameter | Value |
|---|---|
| STATUS (PKN card as of 13.11.2026) | PN-EN 822:2013-07 (English version) withdrawn 02-03-2023; replaced by PN-EN ISO 29465:2023-03; implemented EN 822:2013 |
| Instrument (5.2) | metal rule or tape graduated in millimetres, reading to 0,5 mm; flat surface (5.1) |
| Specimen (6.1–6.2) | full-size product; number according to the product standard or agreement between the parties |
| Storage and testing (6.3, 7.1) | ≥ 6 h at (23 ± 5) °C; in case of dispute (23 ± 2) °C and (50 ± 5) % RH |
| Number of measurements (7.2) | dimensions ≤ 1,5 m — one each; above — an additional one per metre (width at most 5 measurements), equally spaced |
| Result (clause 8) | mean in mm to the nearest 1 mm; length ≥ 3 m rounded to 5 mm |
| Accuracy (clause 9) | the 2013 edition gives no estimate of the accuracy of the method |
| Coverage in accreditation scopes (database, read 13.11.2026) | 4 Polish laboratories, 5 records (2 of them alongside PN-EN ISO 29465); 4 Czech |
Standard
- Standard number
- PN-EN 822:2013-07 (English version; implements EN 822:2013 [IDT]) — withdrawn 02-03-2023, replaced by PN-EN ISO 29465:2023-03
- Title (PL)
- Wyroby do izolacji cieplnej w budownictwie — Określanie długości i szerokości
- Title (EN)
- Thermal insulating products for building applications — Determination of length and width
Step-by-step procedure
-
Specimens
Full-size products in the number given in the product standard; storage ≥ 6 h at (23 ± 5) °C, in case of dispute at (23 ± 2) °C and (50 ± 5) % (clause 6).
-
Placing
The specimen is laid carefully on the flat surface (7.2).
-
Measurement
Dimensions ≤ 1,5 m — one measurement of length and one of width (Fig. 1); above 1,5 m — an additional measurement for each further metre, equally spaced, width at most 5 times (Fig. 2); reading to 1 mm (7.2).
-
Result
Mean for each specimen in mm to the nearest 1 mm; length of products ≥ 3 m rounded to 5 mm (clause 8).
-
Test report
Reference to the standard, product identification (name, manufacturer, code, type, packaging, form on delivery, nominal thickness and density), history and sampling (clause 10).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Flat surface (5.1) | For laying the full-size product | — |
| Metal rule or tape (5.2) | Graduated in millimetres, reading to 0,5 mm; other equipment of at least the same accuracy allowed | — |
Reagents, media and consumables
| Reagent | CAS | Details |
|---|---|---|
| Not applicable | — | Measurement of linear dimensions; the standard lists no reagents |
Health and safety (OHS)
- The standard contains no safety warning in the text read
- TECHNICAL NOTE: PN-EN 822:2013-07 is withdrawn (02-03-2023) — it was replaced by PN-EN ISO 29465:2023-03; two of the five Polish scope items (AB 008, AB 054) give both standards
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN 822:2013-07 (English version; implements EN 822:2013 [IDT]) — withdrawn 02-03-2023, replaced by PN-EN ISO 29465:2023-03 — “Thermal insulating products for building applications — Determination of length and width”.
How does this method work?
A full-size thermal insulating product, stored for at least 6 h at (23 ± 5) °C, is laid carefully on a flat surface and measured directly with a metal rule or tape graduated in millimetres (reading to 0,5 mm): for dimensions up to 1,5 m — one measurement of length and one of width, for larger ones — an additional measurement for each further metre, equally spaced (width at most five times). The result is the mean for the specimen in millimetres to the nearest 1 mm; the length of products of 3 m and more is rounded to 5 mm.
What is the measuring range and accuracy?
STATUS (PKN card as of 13.11.2026): PN-EN 822:2013-07 (English version) withdrawn 02-03-2023; replaced by PN-EN ISO 29465:2023-03; implemented EN 822:2013; Instrument (5.2): metal rule or tape graduated in millimetres, reading to 0,5 mm; flat surface (5.1); Specimen (6.1–6.2): full-size product; number according to the product standard or agreement between the parties; Storage and testing (6.3, 7.1): ≥ 6 h at (23 ± 5) °C; in case of dispute (23 ± 2) °C and (50 ± 5) % RH.
How long does the test take?
The procedure comprises 5 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.
What equipment is required?
Flat surface (5.1), Metal rule or tape (5.2).
Where is this test used?
Thermal insulating products for building applications — full-size products (EN 822:2013, clause 1); A standard from the group of CEN/TC 88 test methods supporting standards for thermal insulating products (foreword); Also outside building, where applicable (foreword); In accreditation scopes: 4 Polish laboratories — EPS, XPS, MW, PUR/PIR, PF, CG, WF, WW and other products; 4 Czech.
What safety precautions apply?
The standard contains no safety warning in the text read; TECHNICAL NOTE: PN-EN 822:2013-07 is withdrawn (02-03-2023) — it was replaced by PN-EN ISO 29465:2023-03; two of the five Polish scope items (AB 008, AB 054) give both standards.
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 822.