⚡ Measurement of overall dimensions of electric and optical fibre cables, circular and flat — up to 25 mm with a micrometer, profile projector or similar apparatus in two perpendicular directions, above 25 mm from the circumference measured with a tape, flat cables along the major and minor axes; PN-EN 60811-203
In short
The overall dimensions of cables (over the insulation of cores or over the sheath) are measured at room temperature: for dimensions up to 25 mm with a micrometer, profile projector or similar apparatus in two directions perpendicular to each other, and for an overall diameter above 25 mm the diameter is calculated from the circumference measured with a measuring tape (or read with a diameter tape). The test is performed according to PN-EN 60811-203:2012 (English version; implements EN 60811-203:2012 and IEC 60811-203:2012 [IDT]); STATUS (as of 22.11.2026): PKN card: PN-EN 60811-203:2012 — English version, published 01-10-2012, 11 pages, KT 53, implements EN 60811-203:2012 and IEC 60811-203:2012 [IDT], replaces PN-EN 60811-1-1:1999 and its amendment A1:2002; the card gives no withdrawal date; the PKN search shows no amendments. The procedure comprises 5 steps; it is used for: Electric and optical fibre cables, circular and flat — dimension over the insulation of cores or over the sheath (clauses 1, 4.1), Measurement as an individual test or as a step in other tests of the IEC 60811 series, e.g. the diameter D for calculating the cross-section of tubular test pieces in IEC 60811-501 (4.1), Flat cables — dimension along the major and minor axes of the cross-section (4.2 c).
At a glance
- Standard: PN-EN 60811-203:2012 (English version; implements EN 60811-203:2012 and IEC 60811-203:2012 [IDT])
- Category: Electronics and EMC
- Procedure steps: 5
- STATUS (as of 22.11.2026): PKN card: PN-EN 60811-203:2012 — English version, published 01-10-2012, 11 pages, KT 53, implements EN 60811-203:2012 and IEC 60811-203:2012 [IDT], replaces PN-EN 60811-1-1:1999 and its amendment A1:2002; the card gives no withdrawal date; the PKN search shows no amendments.
- Dimensions up to 25 mm — instrument (4.2 a): micrometer, profile projector or similar apparatus, two perpendicular directions; in routine tests a dial micrometer or vernier calliper with limited pressure is permitted
- Diameter above 25 mm (4.2 b): circumference measured with a tape and calculation of the diameter, or a direct-reading diameter tape
Overview
WHAT THE STANDARD COVERS. According to clause 1 of IEC 60811-203:2012 the standard gives the methods for measuring overall dimensions and applies to all types of cable, circular and flat. The measurement of overall dimensions over the insulation of cores or over the sheath may be required as an individual test or as a step in other tests; the methods of 4.2 are for general use unless the procedure of a particular test specifies a different method. The method of selecting samples is given in the cable product standard.
ACCORDING TO THE TEXT OF IEC 60811-203:2012 (edition 1.0, 2012-03; the publisher's sample covers the entire content of the standard: foreword, clauses 1–5 and bibliography). The standard was prepared by IEC technical committee TC 20 (electric cables). Part 203 replaces 8.3 of IEC 60811-1-1:1993, which is withdrawn; according to the foreword there are no technical changes compared with the previous edition. The standard is used in conjunction with IEC 60811-100:2012 (general requirements of the series), which we have not read.
PROCEDURE (4.1–4.2). Unless otherwise specified, tests are carried out at room temperature. a) Cables with overall dimensions not exceeding 25 mm — measurement with a micrometer, profile projector or similar apparatus in two directions perpendicular to each other; in routine tests a dial micrometer or a vernier calliper may be used, care being taken to limit the pressure. b) Overall diameter above 25 mm — measurement of the circumference with a measuring tape and calculation of the diameter; alternatively a direct-reading diameter tape. c) Flat cables — measurement along the major and minor axes of the cross-section with a micrometer, profile projector or similar apparatus. Unless otherwise specified in the cable design standard, the reading is made to one decimal place (0,1 mm) for dimensions up to and including 25 mm and to the nearest 0,5 mm for larger dimensions.
RESULT (4.3, clause 5). The results are evaluated according to the requirements of the cable product standard; test report — according to IEC 60811-100.
WHAT WE DO NOT GIVE HERE. The standard gives neither limits for the dimensions nor the number of measurements per sample — these are set by the cable product standard; nor do we reproduce the general requirements of IEC 60811-100 (conditioning, test report), because we have not read it.
STATUS (as of 22.11.2026). PKN card: PN-EN 60811-203:2012 “Kable i przewody elektryczne oraz światłowodowe -- Metody badań materiałów niemetalowych -- Część 203: Badania ogólne -- Pomiar wymiarów zewnętrznych” — English version, published 01-10-2012, 11 pages, KT 53 (cables and wires), implements EN 60811-203:2012 [IDT] and IEC 60811-203:2012 [IDT], replaces PN-EN 60811-1-1:1999 and PN-EN 60811-1-1:1999/A1:2002 (Polish versions); the card gives no withdrawal date. The PKN search shows no amendments to this standard (as of 22.11.2026).
Method principle
The overall dimension of a cable or core is measured directly with an instrument (micrometer, profile projector) in two perpendicular directions, and for a diameter above 25 mm it is determined from the circumference measured with a tape; flat cables are measured along both axes of the cross-section.
Applications
- Electric and optical fibre cables, circular and flat — dimension over the insulation of cores or over the sheath (clauses 1, 4.1)
- Measurement as an individual test or as a step in other tests of the IEC 60811 series, e.g. the diameter D for calculating the cross-section of tubular test pieces in IEC 60811-501 (4.1)
- Flat cables — dimension along the major and minor axes of the cross-section (4.2 c)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 22.11.2026) | PKN card: PN-EN 60811-203:2012 — English version, published 01-10-2012, 11 pages, KT 53, implements EN 60811-203:2012 and IEC 60811-203:2012 [IDT], replaces PN-EN 60811-1-1:1999 and its amendment A1:2002; the card gives no withdrawal date; the PKN search shows no amendments. |
| Dimensions up to 25 mm — instrument (4.2 a) | micrometer, profile projector or similar apparatus, two perpendicular directions; in routine tests a dial micrometer or vernier calliper with limited pressure is permitted |
| Diameter above 25 mm (4.2 b) | circumference measured with a tape and calculation of the diameter, or a direct-reading diameter tape |
| Flat cables (4.2 c) | measurement along the major and minor axes of the cross-section |
| Reading accuracy (4.2) | 0,1 mm for dimensions up to and including 25 mm, 0,5 mm for larger ones — unless the cable design standard specifies otherwise |
| Conditions (4.1) | room temperature, unless otherwise specified |
| Evaluation of the result (4.3) | according to the requirements of the cable product standard |
Standard
- Standard number
- PN-EN 60811-203:2012 (English version; implements EN 60811-203:2012 and IEC 60811-203:2012 [IDT])
- Title (PL)
- Kable i przewody elektryczne oraz światłowodowe — Metody badań materiałów niemetalowych — Część 203: Badania ogólne — Pomiar wymiarów zewnętrznych
- Title (EN)
- Electric and optical fibre cables — Test methods for non-metallic materials — Part 203: General tests — Measurement of overall dimensions
Step-by-step procedure
-
Sample
Sampling according to the cable product standard; test at room temperature unless otherwise specified (4.1).
-
Measurement up to 25 mm
Micrometer, profile projector or similar apparatus, two perpendicular directions; in routine tests a dial micrometer or vernier calliper with limited pressure (4.2 a).
-
Measurement above 25 mm
Circumference with a measuring tape and calculation of the diameter, or reading with a diameter tape (4.2 b).
-
Flat cables
Measurement along the major and minor axes of the cross-section (4.2 c).
-
Reading and evaluation
Reading to 0,1 mm (up to 25 mm) or to 0,5 mm (above 25 mm); evaluation according to the product standard, test report according to IEC 60811-100 (4.2, 4.3, clause 5).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Micrometer or profile projector (4.2 a, c) | Or similar apparatus for measurement in two perpendicular directions; in routine tests a dial micrometer or vernier calliper | — |
| Measuring tape (4.2 b) | For measuring the circumference when the diameter exceeds 25 mm; alternatively a direct-reading diameter tape | — |
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN 60811-203:2012 (English version; implements EN 60811-203:2012 and IEC 60811-203:2012 [IDT]) — “Electric and optical fibre cables — Test methods for non-metallic materials — Part 203: General tests — Measurement of overall dimensions”.
How does this method work?
The overall dimension of a cable or core is measured directly with an instrument (micrometer, profile projector) in two perpendicular directions, and for a diameter above 25 mm it is determined from the circumference measured with a tape; flat cables are measured along both axes of the cross-section.
What is the measuring range and accuracy?
STATUS (as of 22.11.2026): PKN card: PN-EN 60811-203:2012 — English version, published 01-10-2012, 11 pages, KT 53, implements EN 60811-203:2012 and IEC 60811-203:2012 [IDT], replaces PN-EN 60811-1-1:1999 and its amendment A1:2002; the card gives no withdrawal date; the PKN search shows no amendments.; Dimensions up to 25 mm — instrument (4.2 a): micrometer, profile projector or similar apparatus, two perpendicular directions; in routine tests a dial micrometer or vernier calliper with limited pressure is permitted; Diameter above 25 mm (4.2 b): circumference measured with a tape and calculation of the diameter, or a direct-reading diameter tape; Flat cables (4.2 c): measurement along the major and minor axes of the cross-section.
How long does the test take?
The procedure comprises 5 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.
What equipment is required?
Micrometer or profile projector (4.2 a, c), Measuring tape (4.2 b).
Where is this test used?
Electric and optical fibre cables, circular and flat — dimension over the insulation of cores or over the sheath (clauses 1, 4.1); Measurement as an individual test or as a step in other tests of the IEC 60811 series, e.g. the diameter D for calculating the cross-section of tubular test pieces in IEC 60811-501 (4.1); Flat cables — dimension along the major and minor axes of the cross-section (4.2 c).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 60811-203.