🔩 Creep ratio of thermoplastics pipes with a circular cross-section — three pipe pieces aged (21 ± 2) days between flat plates under a constant force for 1 008 h (42 days), force chosen so that after 6 min the deflection is (1,5 ± 0,2) % of the inside diameter, ratio of the deflection extrapolated to 2 years to the deflection after 6 min; PN-EN ISO 9967

Materials and NDT PN-EN ISO 9967

In short

The creep ratio of a thermoplastics pipe is determined by loading a pipe piece between two flat horizontal plates with a constant force for 1 008 h (42 days) and recording the deflection at specified intervals. The test is performed according to PN-EN ISO 9967:2016-02 (Polish version; implements EN ISO 9967:2016 and ISO 9967:2016 [IDT]); STATUS (as of 23.11.2026): PKN card: PN-EN ISO 9967:2016-02 — Polish version, published 20-12-2017, 20 pages, KT 140, implements EN ISO 9967:2016 [IDT] and ISO 9967:2016 [IDT], replaces PN-EN ISO 9967:2008 (Polish version); the card gives no withdrawal date. The procedure comprises 5 steps (about 1 days 8 h in total); it is used for: Thermoplastics pipes with a circular cross-section, including structured-wall pipes with perpendicular and helical ribs (clause 1, 6.2.4–6.2.5), Creep ratio for long-term static calculations of pipes installed in the soil (introduction), Experimental tests with other ages of test pieces, temperatures or durations (introduction).

At a glance

  • Standard: PN-EN ISO 9967:2016-02 (Polish version; implements EN ISO 9967:2016 and ISO 9967:2016 [IDT])
  • Category: Materials and NDT
  • Procedure steps: 5
  • Total time of stages: 1 days 8 h
  • STATUS (as of 23.11.2026): PKN card: PN-EN ISO 9967:2016-02 — Polish version, published 20-12-2017, 20 pages, KT 140, implements EN ISO 9967:2016 [IDT] and ISO 9967:2016 [IDT], replaces PN-EN ISO 9967:2008 (Polish version); the card gives no withdrawal date.
  • Loading time (clause 4): 1 008 h (42 days) of constant compressive force
  • Force F (8.5): chosen so that after 360 s the deflection δ/di = 0,015 ± 0,002, i.e. (1,5 ± 0,2) %; reached within 20–30 s

Overview

WHAT THE STANDARD COVERS. According to clause 1 of ISO 9967:2016 the standard specifies a method for determining the creep ratio of thermoplastics pipes with a circular cross-section. According to the introduction, the deflection of a pipe installed in the soil in accordance with an appropriate code of practice may increase; this period depends on the soil and the installation conditions but normally does not exceed two years — therefore the two-year creep ratio determined according to the standard is intended for long-term static calculations. For experiments, the test can be carried out with other ages of the test pieces, other temperatures or other durations.

ACCORDING TO THE TEXT OF ISO 9967:2016 (edition 3, replacing ISO 9967:2007 after a technical revision; the publisher's sample covers the foreword, the introduction and clauses 1–8.5 — without the rest of the procedure, the calculation of the ratio in clause 9, the test report and Annex A). The standard was prepared by committee ISO/TC 138/SC 5. The diameter is measured according to ISO 3126.

PRINCIPLE (clause 4). A cut length of pipe is placed between two flat horizontal plates and a constant compressive force is applied for 1 008 h (42 days). The deflection of the pipe is recorded at specified intervals to prepare a plot of deflection against time; the linearity of the data is analysed and the creep ratio is calculated as the ratio of the deflection extrapolated to two years to the deflection measured after 6 min (0,1 h). The test temperature is set, where appropriate, by the referring standard.

APPARATUS (clause 5). Loading machine acting through the plates and maintaining to within ± 1 % the pre-load force F0 and the loading force F (directly or e.g. by a lever arm). Two flat, smooth and clean plates, not deforming to an extent affecting the result; length at least equal to the length of the test piece, width not less than the maximum width of contact with the test piece under load plus 25 mm. Measuring devices: for the length of the test piece to ± 1 mm, the inside diameter to ± 0,1 mm or ± 0,2 % di (whichever is greater) and the change in inside diameter in the direction of loading to 0,1 mm or 0,1 % of the deflection (whichever is greater); the change in diameter may be measured inside the pipe or from the movement of the upper plate, in case of dispute the inside diameter is the reference. Timer: the first 6 min to within 1 s, the remaining times to 0,1 %.

TEST PIECES (clause 6). The pipe is marked with a line along a generatrix over its full length, and three test pieces A, B and C with ends perpendicular to the axis are cut from it. The length of a test piece is the average of 3 (dn ≤ 200 mm), 4 (200 mm < dn < 500 mm) or 6 (dn ≥ 500 mm) measurements equally spaced around the perimeter, each to within 1 mm; the smallest measurement shall not be less than 0,9 times the largest. Average length: (300 ± 10) mm for dn ≤ 1 500 mm, at least 0,2 dn for dn > 1 500 mm. Structured-wall pipes with perpendicular ribs are cut midway between the ribs so that the test piece has a whole number of ribs and a length of at least 290 mm (or 0,2 dn for pipes above 1 500 mm); pipes with helical ribs — cut square to a length equal to the inside diameter ± 20 mm, not less than 290 mm and not more than 1 000 mm. The inside diameter of each test piece is determined as the average of at least four measurements in the cross-section at mid-length (according to ISO 3126) or with a π-tape, and di is the average of the three test pieces. Age of the test pieces at the start of the test: (21 ± 2) days.

CONDITIONING AND PROCEDURE (clause 7, 8.1–8.5). The test pieces are conditioned in air at the test temperature for at least 24 h immediately before testing. Unless the referring standard specifies otherwise, the test is carried out at (23 ± 2) °C, and in countries where 27 °C is the standard laboratory temperature at (27 ± 2) °C; in case of dispute (23 ± 2) °C is used. Test piece A is placed in the position of the lowest ring stiffness, if it can be determined, and otherwise with the marking line against the upper plate; test pieces B and C are rotated by 120° and 240°. The loading plate is lowered until it touches the test piece and the pre-load F0 is applied: 7,5 N for di ≤ 100 mm, and for di > 100 mm F0 = 250 × 10⁻⁶ di × L1 in newtons (di and L1 — mean inside diameter and mean length of the test piece in millimetres), rounded up to the next integer; the force actually applied is to be 95–105 % of the calculated one. Within 5 min of applying F0 the deflection gauge is set to zero and within 20–30 s the force is increased to F, chosen so that after 360 s (6 min) the relative deflection δ/di is 0,015 ± 0,002, i.e. (1,5 ± 0,2) %; the time is measured from the moment the full force F is reached.

WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. The force F is chosen for the deflection after 6 min, not in advance — with a deflection after 6 min outside (1,5 ± 0,2) % the condition of 8.5 is not met; the age of the test pieces of (21 ± 2) days at the start and conditioning for at least 24 h affect creep; in case of dispute the change in diameter is measured inside the pipe, not from the movement of the plate.

WHAT WE DO NOT GIVE HERE. The reading intervals of the deflection after 6 min, the linearity analysis and extrapolation (clause 9), the formula for the creep ratio γ, the test report and the theory of creep from Annex A — the sample ends at 8.5, and we have not read these parts of the standard.

STATUS (as of 23.11.2026). PKN card: PN-EN ISO 9967:2016-02 “Rury z tworzyw termoplastycznych -- Oznaczanie wskaźnika pełzania” — Polish version, published 20-12-2017, 20 pages, KT 140 (plastics pipes, fittings and valves), implements EN ISO 9967:2016 [IDT] and ISO 9967:2016 [IDT], replaces PN-EN ISO 9967:2008 (Polish version); the card gives no withdrawal date.

Method principle

The pipe is loaded between plates with a constant force for 42 days and the deflection is recorded at specified intervals; the data are analysed for linearity (the list of symbols of the standard mentions linear regression and x = log(t)), the deflection is extrapolated to two years, and its ratio to the deflection after 6 min is the creep ratio.

Applications

Key parameters

ParameterValue
STATUS (as of 23.11.2026)PKN card: PN-EN ISO 9967:2016-02 — Polish version, published 20-12-2017, 20 pages, KT 140, implements EN ISO 9967:2016 [IDT] and ISO 9967:2016 [IDT], replaces PN-EN ISO 9967:2008 (Polish version); the card gives no withdrawal date.
Loading time (clause 4)1 008 h (42 days) of constant compressive force
Force F (8.5)chosen so that after 360 s the deflection δ/di = 0,015 ± 0,002, i.e. (1,5 ± 0,2) %; reached within 20–30 s
Pre-load F0 (8.4)di ≤ 100 mm: 7,5 N; di > 100 mm: F0 = 250 × 10⁻⁶ di × L1 [N], rounded up; applied 95–105 % of the calculated value
Result (clause 4)creep ratio = deflection extrapolated to 2 years / deflection after 6 min (0,1 h)
Test pieces (6.1–6.2)three (A, B, C); average length (300 ± 10) mm for dn ≤ 1 500 mm, at least 0,2 dn above; 3, 4 or 6 length measurements depending on dn; smallest ≥ 0,9 of the largest
Age and conditioning (6.4, clause 7)(21 ± 2) days at the start of the test; at least 24 h in air at the test temperature
Temperature (8.1)(23 ± 2) °C or (27 ± 2) °C in countries with that laboratory temperature; in case of dispute (23 ± 2) °C
Position of test pieces (8.2)A in the position of the lowest stiffness (or with the line against the upper plate), B and C rotated by 120° and 240°

Standard

Standard number
PN-EN ISO 9967:2016-02 (Polish version; implements EN ISO 9967:2016 and ISO 9967:2016 [IDT])
Title (PL)
Rury z tworzyw termoplastycznych — Oznaczanie wskaźnika pełzania
Title (EN)
Thermoplastics pipes — Determination of creep ratio

Step-by-step procedure

  1. Test pieces

    Line along a generatrix of the pipe; three test pieces A, B, C; measurement of length (3–6 measurements) and inside diameter according to ISO 3126; age (21 ± 2) days (6.1–6.4).

  2. Conditioning

    In air at the test temperature, immediately before testing (clause 7).

    ⏱ Time: at least 24 h • 🌡 Temperature: (23 ± 2) °C

  3. Positioning

    A in the position of the lowest stiffness or with the line against the upper plate, B and C rotated by 120° and 240°; deflection gauge (8.2, 8.3).

  4. Pre-load

    Plate lowered to touch the test piece; F0 = 7,5 N (di ≤ 100 mm) or 250 × 10⁻⁶ di × L1 (8.4).

  5. Loading

    Within 5 min, gauge set to zero, force raised to F within 20–30 s; F chosen for a deflection of (1,5 ± 0,2) % after 6 min; timer started at full force; loading for 1 008 h with deflection readings (8.5, clause 4).

    ⏱ Time: 1 008 h

Required equipment and apparatus

EquipmentExampleIndicative price
Loading machine (5.1)Maintains F0 and F to within ± 1 %, directly or e.g. by a lever arm—
Two flat plates (5.2)Smooth, clean, non-deforming; length ≥ test piece length, width ≥ contact width under load + 25 mm—
Dimensional measuring devices (5.3)Length ± 1 mm; inside diameter ± 0,1 mm or ± 0,2 % di; change in diameter 0,1 mm or 0,1 % of the deflection (whichever is greater)—
Timer (5.4)First 6 min to within 1 s, remaining times to 0,1 %—

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-EN ISO 9967:2016-02 (Polish version; implements EN ISO 9967:2016 and ISO 9967:2016 [IDT]) — “Thermoplastics pipes — Determination of creep ratio”.

How does this method work?

The pipe is loaded between plates with a constant force for 42 days and the deflection is recorded at specified intervals; the data are analysed for linearity (the list of symbols of the standard mentions linear regression and x = log(t)), the deflection is extrapolated to two years, and its ratio to the deflection after 6 min is the creep ratio.

What is the measuring range and accuracy?

STATUS (as of 23.11.2026): PKN card: PN-EN ISO 9967:2016-02 — Polish version, published 20-12-2017, 20 pages, KT 140, implements EN ISO 9967:2016 [IDT] and ISO 9967:2016 [IDT], replaces PN-EN ISO 9967:2008 (Polish version); the card gives no withdrawal date.; Loading time (clause 4): 1 008 h (42 days) of constant compressive force; Force F (8.5): chosen so that after 360 s the deflection δ/di = 0,015 ± 0,002, i.e. (1,5 ± 0,2) %; reached within 20–30 s; Pre-load F0 (8.4): di ≤ 100 mm: 7,5 N; di > 100 mm: F0 = 250 × 10⁻⁶ di × L1 [N], rounded up; applied 95–105 % of the calculated value.

How long does the test take?

The times given for the individual stages add up to approximately 1 days 8 h. The procedure comprises 5 steps.

What equipment is required?

Loading machine (5.1), Two flat plates (5.2), Dimensional measuring devices (5.3), Timer (5.4).

Where is this test used?

Thermoplastics pipes with a circular cross-section, including structured-wall pipes with perpendicular and helical ribs (clause 1, 6.2.4–6.2.5); Creep ratio for long-term static calculations of pipes installed in the soil (introduction); Experimental tests with other ages of test pieces, temperatures or durations (introduction).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN ISO 9967.

🔍 Find a laboratory performing this test