💡 Rope lights: particular requirements — Class II or III only, at least IP 44 outdoors, pipe tests: pull of 60 N 45 times for 1 s, torque of 0,15 Nm for 1 min, winding on a 150 mm cylinder with 60 N at 25 °C and –15 °C, bending on a mandrel after 16 h at –15 °C; PN-EN 60598-2-21

Electronics and EMC PN-EN 60598-2-21

In short

Particular requirements for rope lights (sealed lighting chains) with non-replaceable light sources connected in series, in parallel or in series/parallel, for use indoors and outdoors on supply voltages up to 250 V. The test is performed according to PN-EN 60598-2-21:2015-07 (English version, published 09-07-2015; implements EN 60598-2-21:2015 and IEC 60598-2-21:2014 [IDT]) with corrigendum PN-EN 60598-2-21:2015-07/AC:2017-03; STATUS (as of 26.11.2026): PKN card: PN-EN 60598-2-21:2015-07 — English version (09-07-2015, 26 pages), KT 4 (lighting technology), implements EN 60598-2-21:2015 [IDT] and IEC 60598-2-21:2014 [IDT], directive 2014/35/EU; corrigendum AC:2017-03 (EN 60598-2-21:2015/AC:2017-01, IEC 60598-2-21:2014/COR1:2016); the card gives no withdrawal date. The procedure comprises 5 steps (about 1 days 8 h 2 min in total); it is used for: Rope lights (sealed lighting chains) with non-replaceable light sources, indoors and outdoors, up to 250 V (21.1), Rigid and flexible rope lights — mechanical tests of the pipe (21.7.5), Rope lights interconnected into systems — connectors according to Annex A, marking of the maximum length and wattage (21.6.4, 21.7.3).

At a glance

  • Standard: PN-EN 60598-2-21:2015-07 (English version, published 09-07-2015; implements EN 60598-2-21:2015 and IEC 60598-2-21:2014 [IDT]) with corrigendum PN-EN 60598-2-21:2015-07/AC:2017-03
  • Category: Electronics and EMC
  • Procedure steps: 5
  • Total time of stages: 1 days 8 h 2 min
  • STATUS (as of 26.11.2026): PKN card: PN-EN 60598-2-21:2015-07 — English version (09-07-2015, 26 pages), KT 4 (lighting technology), implements EN 60598-2-21:2015 [IDT] and IEC 60598-2-21:2014 [IDT], directive 2014/35/EU; corrigendum AC:2017-03 (EN 60598-2-21:2015/AC:2017-01, IEC 60598-2-21:2014/COR1:2016); the card gives no withdrawal date.
  • Scope (21.1): rope lights with non-replaceable light sources, supply voltage up to 250 V, indoors and outdoors
  • Classification (21.5): Class II or III only; outdoor — at least IP 44

Overview

WHAT THE STANDARD COVERS. According to 21.1 of IEC 60598-2-21:2014 the standard specifies requirements for rope lights (sealed lighting chains) fitted with non-replaceable series-, parallel- or series/parallel-connected light sources for use indoors or outdoors on supply voltages not exceeding 250 V. A rope light is a lighting chain with non-replaceable light sources enclosed in a rigid or flexible insulating translucent pipe or tube, sealed at the ends, with or without joints; it may incorporate control devices, e.g. flasher units (21.3.2). According to the notes, in some countries the term "sealed lighting chain" is used, and for products fixed to a frame as ornaments (e.g. Santa Claus, snowman) the relevant clauses of IEC 60598-2-4 or IEC 60598-2-7 can also apply; rope lights with extra ornamental attachments (e.g. in festive decorations or in two- or three-dimensional reproductions of persons and animals) are covered by the standard. The standard is read together with IEC 60598-1; the tests are carried out in the order listed in Part 2-21 (21.4).

ACCORDING TO THE TEXT OF IEC 60598-2-21:2014 (edition 1.0, 2014-11, with the content of Corrigendum 1 of December 2016; the publisher's sample covers the foreword and clauses 21.1–21.7.5 b) 4)). The standard was prepared by subcommittee IEC SC 34D of IEC TC 34. Normative references include: IEC 60227-5:2011 and IEC 60245-4:2011 (PVC- and rubber-insulated flexible cables), IEC 60320 (appliance couplers), IEC 60529 (IP code), IEC 60811-504, -506 and -508:2012 (low-temperature bending and impact tests, high-temperature pressure test of insulation and sheaths), IEC 60906 (plugs and socket-outlets), IEC 61347-2-11 and IEC 61347-2-13, IEC 61984:2008 (connectors).

CLASSIFICATION AND MARKING (21.5, 21.6). Rope lights are classified only as Class II or Class III; for outdoor use — at least IP 44. On the rope light: rated voltage and rated wattage of the complete rope light (on the cable — on a durable, non-removable sleeve or label). Rope lights for indoor use only: "FOR INDOOR USE ONLY" on the rope light and the packing, or the symbol IEC 60417-5957 (2004-12) explained in the instructions. On the packing or in the instructions, among others: do not connect the rope light while in the packing or wound onto a reel; do not use it covered or recessed into a surface; minimum allowed bending radius; "Do not open or cut the rope light"; the gasket warning; interconnection rules (only with products of the same manufacturer, only with the supplied connectors, sealing of open ends, maximum system length and wattage); information on bridging devices; for Class III without a supply source — information on the required supply source.

CONSTRUCTION (21.7). Clause 4.6 of Part 1 (terminal blocks) does not apply; interconnecting connectors additionally comply with Annex A (21.7.2, 21.7.3). Control units forming part of the rope light — in non-flammable insulating material, securely fixed to the rope light or the cable; electronic control devices (e.g. flasher units) — also IEC 61347-2-11, LED drivers — IEC 61347-2-13 (21.7.4). Mechanical strength (21.7.5): a) rigid pipe — in turn 1) a pull of 60 N applied to the ends of the pipe, 45 times without jerks, each time for 1 s; 2) a torque of 0,15 Nm applied to the ends of the pipe in the most unfavourable direction (in case of doubt — alternately), without jerks, for 1 min; during and after the tests the conductors shall not have moved noticeably in the terminals and the pipe shall not be damaged; b) flexible pipe — tests 1) and 2), then 3) winding the full test length (1 m) on a cylinder of 150 mm diameter with a pull of 60 N: with IP20 — 10 times at 25 °C ± 2 °C, with a degree of protection over X0 — 10 times at 25 °C ± 2 °C and 10 times at –15 °C ± 2 °C, before the low-temperature tests the pipe is kept for 16 h in a low-temperature cabinet at –15 °C ± 2 °C (example of a device — Figure 1: wooden cylinder, 60 N weight, 1 000 mm length); 4) after test 3) the specimen at room temperature is wound on a mandrel of 4–5 times the specimen diameter, placed for 16 h in the low-temperature cabinet (–15 °C ± 2 °C) and wound two turns around the mandrel in the cabinet — no cracks (example of an apparatus — Figure 2, corresponding to Figure 1 of IEC 60811-504:2012).

CORRIGENDUM (AC:2017-03, implements EN 60598-2-21:2015/AC:2017-01 = IEC 60598-2-21:2014/COR1:2016, approved by the President of PKN on 28 March 2017). It concerns Annex A (connectors): in 5.4, first paragraph — "f)" replaced by "g)"; in 6.14.2 (electrical endurance of CBC connectors) — "7.3.8" replaced by "7.3.5"; in 6.14.3 (bending of non-rewirable connectors) — "7.3.9" replaced by "7.3.10".

WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. A flexible pipe with a degree of protection over X0 is also wound at –15 °C after 16 h of conditioning, and then undergoes a second test on the mandrel — performing only room-temperature tests does not check cracking in the cold. The force of 60 N and the torque of 0,15 Nm are applied without jerks.

WHAT WE DO NOT GIVE HERE. Clauses 21.8–21.16 (creepage distances and clearances, earthing, terminals, cables for rope lights — Table 2, cord anchorage test, plugs and cable length, maximum length of extendable Class II rope lights, endurance and thermal tests, short-circuit test of rectifier, dust and moisture, insulation, resistance to heat and fire), Figure 3 (impact test apparatus), Table 1 (mass of hammer) or the content of Annex A — the sample breaks off at 21.7.5 b) 4); we know them only from the titles in the table of contents.

STATUS (as of 26.11.2026). PKN card: PN-EN 60598-2-21:2015-07 "Oprawy oświetleniowe -- Część 2-21: Wymagania szczegółowe -- Węże świetlne" — English version (published 09-07-2015, 26 pages), KT 4 (lighting technology), implements EN 60598-2-21:2015 [IDT] and IEC 60598-2-21:2014 [IDT], directive 2014/35/EU, additional element: corrigendum PN-EN 60598-2-21:2015-07/AC:2017-03; the card gives no withdrawal date.

Method principle

The rope light is tested according to IEC 60598-1 in the order listed in Part 2-21: the class (only II or III) and IP degree (at least IP 44 outdoors), marking and instructions are checked, and the strength of the pipe — by a pull of 60 N 45 times for 1 s and a torque of 0,15 Nm for 1 min, a flexible pipe additionally by winding on a 150 mm cylinder with 60 N at 25 °C and –15 °C and by winding on a mandrel after 16 h at –15 °C, without cracks.

Applications

Key parameters

ParameterValue
STATUS (as of 26.11.2026)PKN card: PN-EN 60598-2-21:2015-07 — English version (09-07-2015, 26 pages), KT 4 (lighting technology), implements EN 60598-2-21:2015 [IDT] and IEC 60598-2-21:2014 [IDT], directive 2014/35/EU; corrigendum AC:2017-03 (EN 60598-2-21:2015/AC:2017-01, IEC 60598-2-21:2014/COR1:2016); the card gives no withdrawal date.
Scope (21.1)rope lights with non-replaceable light sources, supply voltage up to 250 V, indoors and outdoors
Classification (21.5)Class II or III only; outdoor — at least IP 44
Pull on the pipe (21.7.5 a) 1))60 N on the ends of the pipe, 45 times without jerks, for 1 s each
Torque on the pipe (21.7.5 a) 2))0,15 Nm, most unfavourable direction, 1 min
Winding of a flexible pipe (21.7.5 b) 3))1 m specimen on a 150 mm cylinder with 60 N; IP20 — 10 times at 25 °C ± 2 °C; over X0 — additionally 10 times at –15 °C ± 2 °C after 16 h of conditioning
Bending in the cold (21.7.5 b) 4))mandrel of 4–5 specimen diameters, 16 h at –15 °C ± 2 °C, two turns in the cabinet — no cracks
Corrigendum AC:2017-03 (Annex A)5.4: "f)" → "g)"; 6.14.2: "7.3.8" → "7.3.5"; 6.14.3: "7.3.9" → "7.3.10"

Standard

Standard number
PN-EN 60598-2-21:2015-07 (English version, published 09-07-2015; implements EN 60598-2-21:2015 and IEC 60598-2-21:2014 [IDT]) with corrigendum PN-EN 60598-2-21:2015-07/AC:2017-03
Title (PL)
Oprawy oświetleniowe — Część 2-21: Wymagania szczegółowe — Węże świetlne
Title (EN)
Luminaires — Part 2-21: Particular requirements — Rope lights

Step-by-step procedure

  1. Classification and marking

    Class II or III, at least IP 44 outdoors (21.5); voltage and wattage of the rope light, "indoor use only" text or symbol, information on the packing or in the instructions (21.6).

  2. Construction

    No terminal blocks of 4.6 of Part 1; connectors according to Annex A with corrigendum AC; control units in non-flammable material, flasher units — IEC 61347-2-11, LED drivers — IEC 61347-2-13 (21.7.2–21.7.4).

  3. Pull and torque

    Pull of 60 N 45 times for 1 s, then torque of 0,15 Nm for 1 min; conductors without noticeable movement in the terminals, pipe undamaged (21.7.5 a)).

    ⏱ Time: about 2 min

  4. Winding of a flexible pipe

    1 m specimen on a 150 mm cylinder with 60 N: 10 times at 25 °C ± 2 °C, and with a degree of protection over X0 also 10 times at –15 °C ± 2 °C after 16 h of conditioning (21.7.5 b) 3)).

    ⏱ Time: 16 h conditioning

  5. Bending in the cold

    Winding on a mandrel of 4–5 specimen diameters, 16 h at –15 °C ± 2 °C, two turns around the mandrel in the cabinet — no cracks (21.7.5 b) 4)).

    ⏱ Time: 16 h

Required equipment and apparatus

EquipmentExampleIndicative price
Device for winding a flexible pipe (Figure 1, 21.7.5 b) 3))Wooden cylinder of 150 mm diameter, 60 N weight, 1 000 mm specimen—
Low-temperature cabinet –15 °C ± 2 °C (21.7.5 b) 3), 4))Conditioning for 16 h—
Mandrel of 4–5 times the specimen diameter (Figure 2, 21.7.5 b) 4))Corresponds to Figure 1 of IEC 60811-504:2012—
Devices for a pull of 60 N and a torque of 0,15 Nm (21.7.5 a))Loading without jerks—

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-EN 60598-2-21:2015-07 (English version, published 09-07-2015; implements EN 60598-2-21:2015 and IEC 60598-2-21:2014 [IDT]) with corrigendum PN-EN 60598-2-21:2015-07/AC:2017-03 — “Luminaires — Part 2-21: Particular requirements — Rope lights”.

How does this method work?

The rope light is tested according to IEC 60598-1 in the order listed in Part 2-21: the class (only II or III) and IP degree (at least IP 44 outdoors), marking and instructions are checked, and the strength of the pipe — by a pull of 60 N 45 times for 1 s and a torque of 0,15 Nm for 1 min, a flexible pipe additionally by winding on a 150 mm cylinder with 60 N at 25 °C and –15 °C and by winding on a mandrel after 16 h at –15 °C, without cracks.

What is the measuring range and accuracy?

STATUS (as of 26.11.2026): PKN card: PN-EN 60598-2-21:2015-07 — English version (09-07-2015, 26 pages), KT 4 (lighting technology), implements EN 60598-2-21:2015 [IDT] and IEC 60598-2-21:2014 [IDT], directive 2014/35/EU; corrigendum AC:2017-03 (EN 60598-2-21:2015/AC:2017-01, IEC 60598-2-21:2014/COR1:2016); the card gives no withdrawal date.; Scope (21.1): rope lights with non-replaceable light sources, supply voltage up to 250 V, indoors and outdoors; Classification (21.5): Class II or III only; outdoor — at least IP 44; Pull on the pipe (21.7.5 a) 1)): 60 N on the ends of the pipe, 45 times without jerks, for 1 s each.

How long does the test take?

The times given for the individual stages add up to approximately 1 days 8 h 2 min. The procedure comprises 5 steps.

What equipment is required?

Device for winding a flexible pipe (Figure 1, 21.7.5 b) 3)), Low-temperature cabinet –15 °C ± 2 °C (21.7.5 b) 3), 4)), Mandrel of 4–5 times the specimen diameter (Figure 2, 21.7.5 b) 4)), Devices for a pull of 60 N and a torque of 0,15 Nm (21.7.5 a)).

Where is this test used?

Rope lights (sealed lighting chains) with non-replaceable light sources, indoors and outdoors, up to 250 V (21.1); Rigid and flexible rope lights — mechanical tests of the pipe (21.7.5); Rope lights interconnected into systems — connectors according to Annex A, marking of the maximum length and wattage (21.6.4, 21.7.3); Rope lights with ornamental attachments and control units (flasher units, LED drivers) (21.1, 21.7.4).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 60598-2-21.

🔍 Find a laboratory performing this test