💡 Rope lights: particular requirements — Class II or III only, at least IP 44 outdoors, pipe tests: pull of 60 N 45 times for 1 s, torque of 0,15 Nm for 1 min, winding on a 150 mm cylinder with 60 N at 25 °C and –15 °C, bending on a mandrel after 16 h at –15 °C; PN-EN 60598-2-21
In short
Particular requirements for rope lights (sealed lighting chains) with non-replaceable light sources connected in series, in parallel or in series/parallel, for use indoors and outdoors on supply voltages up to 250 V. The test is performed according to PN-EN 60598-2-21:2015-07 (English version, published 09-07-2015; implements EN 60598-2-21:2015 and IEC 60598-2-21:2014 [IDT]) with corrigendum PN-EN 60598-2-21:2015-07/AC:2017-03; STATUS (as of 26.11.2026): PKN card: PN-EN 60598-2-21:2015-07 — English version (09-07-2015, 26 pages), KT 4 (lighting technology), implements EN 60598-2-21:2015 [IDT] and IEC 60598-2-21:2014 [IDT], directive 2014/35/EU; corrigendum AC:2017-03 (EN 60598-2-21:2015/AC:2017-01, IEC 60598-2-21:2014/COR1:2016); the card gives no withdrawal date. The procedure comprises 5 steps (about 1 days 8 h 2 min in total); it is used for: Rope lights (sealed lighting chains) with non-replaceable light sources, indoors and outdoors, up to 250 V (21.1), Rigid and flexible rope lights — mechanical tests of the pipe (21.7.5), Rope lights interconnected into systems — connectors according to Annex A, marking of the maximum length and wattage (21.6.4, 21.7.3).
At a glance
- Standard: PN-EN 60598-2-21:2015-07 (English version, published 09-07-2015; implements EN 60598-2-21:2015 and IEC 60598-2-21:2014 [IDT]) with corrigendum PN-EN 60598-2-21:2015-07/AC:2017-03
- Category: Electronics and EMC
- Procedure steps: 5
- Total time of stages: 1 days 8 h 2 min
- STATUS (as of 26.11.2026): PKN card: PN-EN 60598-2-21:2015-07 — English version (09-07-2015, 26 pages), KT 4 (lighting technology), implements EN 60598-2-21:2015 [IDT] and IEC 60598-2-21:2014 [IDT], directive 2014/35/EU; corrigendum AC:2017-03 (EN 60598-2-21:2015/AC:2017-01, IEC 60598-2-21:2014/COR1:2016); the card gives no withdrawal date.
- Scope (21.1): rope lights with non-replaceable light sources, supply voltage up to 250 V, indoors and outdoors
- Classification (21.5): Class II or III only; outdoor — at least IP 44
Overview
WHAT THE STANDARD COVERS. According to 21.1 of IEC 60598-2-21:2014 the standard specifies requirements for rope lights (sealed lighting chains) fitted with non-replaceable series-, parallel- or series/parallel-connected light sources for use indoors or outdoors on supply voltages not exceeding 250 V. A rope light is a lighting chain with non-replaceable light sources enclosed in a rigid or flexible insulating translucent pipe or tube, sealed at the ends, with or without joints; it may incorporate control devices, e.g. flasher units (21.3.2). According to the notes, in some countries the term "sealed lighting chain" is used, and for products fixed to a frame as ornaments (e.g. Santa Claus, snowman) the relevant clauses of IEC 60598-2-4 or IEC 60598-2-7 can also apply; rope lights with extra ornamental attachments (e.g. in festive decorations or in two- or three-dimensional reproductions of persons and animals) are covered by the standard. The standard is read together with IEC 60598-1; the tests are carried out in the order listed in Part 2-21 (21.4).
ACCORDING TO THE TEXT OF IEC 60598-2-21:2014 (edition 1.0, 2014-11, with the content of Corrigendum 1 of December 2016; the publisher's sample covers the foreword and clauses 21.1–21.7.5 b) 4)). The standard was prepared by subcommittee IEC SC 34D of IEC TC 34. Normative references include: IEC 60227-5:2011 and IEC 60245-4:2011 (PVC- and rubber-insulated flexible cables), IEC 60320 (appliance couplers), IEC 60529 (IP code), IEC 60811-504, -506 and -508:2012 (low-temperature bending and impact tests, high-temperature pressure test of insulation and sheaths), IEC 60906 (plugs and socket-outlets), IEC 61347-2-11 and IEC 61347-2-13, IEC 61984:2008 (connectors).
CLASSIFICATION AND MARKING (21.5, 21.6). Rope lights are classified only as Class II or Class III; for outdoor use — at least IP 44. On the rope light: rated voltage and rated wattage of the complete rope light (on the cable — on a durable, non-removable sleeve or label). Rope lights for indoor use only: "FOR INDOOR USE ONLY" on the rope light and the packing, or the symbol IEC 60417-5957 (2004-12) explained in the instructions. On the packing or in the instructions, among others: do not connect the rope light while in the packing or wound onto a reel; do not use it covered or recessed into a surface; minimum allowed bending radius; "Do not open or cut the rope light"; the gasket warning; interconnection rules (only with products of the same manufacturer, only with the supplied connectors, sealing of open ends, maximum system length and wattage); information on bridging devices; for Class III without a supply source — information on the required supply source.
CONSTRUCTION (21.7). Clause 4.6 of Part 1 (terminal blocks) does not apply; interconnecting connectors additionally comply with Annex A (21.7.2, 21.7.3). Control units forming part of the rope light — in non-flammable insulating material, securely fixed to the rope light or the cable; electronic control devices (e.g. flasher units) — also IEC 61347-2-11, LED drivers — IEC 61347-2-13 (21.7.4). Mechanical strength (21.7.5): a) rigid pipe — in turn 1) a pull of 60 N applied to the ends of the pipe, 45 times without jerks, each time for 1 s; 2) a torque of 0,15 Nm applied to the ends of the pipe in the most unfavourable direction (in case of doubt — alternately), without jerks, for 1 min; during and after the tests the conductors shall not have moved noticeably in the terminals and the pipe shall not be damaged; b) flexible pipe — tests 1) and 2), then 3) winding the full test length (1 m) on a cylinder of 150 mm diameter with a pull of 60 N: with IP20 — 10 times at 25 °C ± 2 °C, with a degree of protection over X0 — 10 times at 25 °C ± 2 °C and 10 times at –15 °C ± 2 °C, before the low-temperature tests the pipe is kept for 16 h in a low-temperature cabinet at –15 °C ± 2 °C (example of a device — Figure 1: wooden cylinder, 60 N weight, 1 000 mm length); 4) after test 3) the specimen at room temperature is wound on a mandrel of 4–5 times the specimen diameter, placed for 16 h in the low-temperature cabinet (–15 °C ± 2 °C) and wound two turns around the mandrel in the cabinet — no cracks (example of an apparatus — Figure 2, corresponding to Figure 1 of IEC 60811-504:2012).
CORRIGENDUM (AC:2017-03, implements EN 60598-2-21:2015/AC:2017-01 = IEC 60598-2-21:2014/COR1:2016, approved by the President of PKN on 28 March 2017). It concerns Annex A (connectors): in 5.4, first paragraph — "f)" replaced by "g)"; in 6.14.2 (electrical endurance of CBC connectors) — "7.3.8" replaced by "7.3.5"; in 6.14.3 (bending of non-rewirable connectors) — "7.3.9" replaced by "7.3.10".
WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. A flexible pipe with a degree of protection over X0 is also wound at –15 °C after 16 h of conditioning, and then undergoes a second test on the mandrel — performing only room-temperature tests does not check cracking in the cold. The force of 60 N and the torque of 0,15 Nm are applied without jerks.
WHAT WE DO NOT GIVE HERE. Clauses 21.8–21.16 (creepage distances and clearances, earthing, terminals, cables for rope lights — Table 2, cord anchorage test, plugs and cable length, maximum length of extendable Class II rope lights, endurance and thermal tests, short-circuit test of rectifier, dust and moisture, insulation, resistance to heat and fire), Figure 3 (impact test apparatus), Table 1 (mass of hammer) or the content of Annex A — the sample breaks off at 21.7.5 b) 4); we know them only from the titles in the table of contents.
STATUS (as of 26.11.2026). PKN card: PN-EN 60598-2-21:2015-07 "Oprawy oświetleniowe -- Część 2-21: Wymagania szczegółowe -- Węże świetlne" — English version (published 09-07-2015, 26 pages), KT 4 (lighting technology), implements EN 60598-2-21:2015 [IDT] and IEC 60598-2-21:2014 [IDT], directive 2014/35/EU, additional element: corrigendum PN-EN 60598-2-21:2015-07/AC:2017-03; the card gives no withdrawal date.
Method principle
The rope light is tested according to IEC 60598-1 in the order listed in Part 2-21: the class (only II or III) and IP degree (at least IP 44 outdoors), marking and instructions are checked, and the strength of the pipe — by a pull of 60 N 45 times for 1 s and a torque of 0,15 Nm for 1 min, a flexible pipe additionally by winding on a 150 mm cylinder with 60 N at 25 °C and –15 °C and by winding on a mandrel after 16 h at –15 °C, without cracks.
Applications
- Rope lights (sealed lighting chains) with non-replaceable light sources, indoors and outdoors, up to 250 V (21.1)
- Rigid and flexible rope lights — mechanical tests of the pipe (21.7.5)
- Rope lights interconnected into systems — connectors according to Annex A, marking of the maximum length and wattage (21.6.4, 21.7.3)
- Rope lights with ornamental attachments and control units (flasher units, LED drivers) (21.1, 21.7.4)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 26.11.2026) | PKN card: PN-EN 60598-2-21:2015-07 — English version (09-07-2015, 26 pages), KT 4 (lighting technology), implements EN 60598-2-21:2015 [IDT] and IEC 60598-2-21:2014 [IDT], directive 2014/35/EU; corrigendum AC:2017-03 (EN 60598-2-21:2015/AC:2017-01, IEC 60598-2-21:2014/COR1:2016); the card gives no withdrawal date. |
| Scope (21.1) | rope lights with non-replaceable light sources, supply voltage up to 250 V, indoors and outdoors |
| Classification (21.5) | Class II or III only; outdoor — at least IP 44 |
| Pull on the pipe (21.7.5 a) 1)) | 60 N on the ends of the pipe, 45 times without jerks, for 1 s each |
| Torque on the pipe (21.7.5 a) 2)) | 0,15 Nm, most unfavourable direction, 1 min |
| Winding of a flexible pipe (21.7.5 b) 3)) | 1 m specimen on a 150 mm cylinder with 60 N; IP20 — 10 times at 25 °C ± 2 °C; over X0 — additionally 10 times at –15 °C ± 2 °C after 16 h of conditioning |
| Bending in the cold (21.7.5 b) 4)) | mandrel of 4–5 specimen diameters, 16 h at –15 °C ± 2 °C, two turns in the cabinet — no cracks |
| Corrigendum AC:2017-03 (Annex A) | 5.4: "f)" → "g)"; 6.14.2: "7.3.8" → "7.3.5"; 6.14.3: "7.3.9" → "7.3.10" |
Standard
- Standard number
- PN-EN 60598-2-21:2015-07 (English version, published 09-07-2015; implements EN 60598-2-21:2015 and IEC 60598-2-21:2014 [IDT]) with corrigendum PN-EN 60598-2-21:2015-07/AC:2017-03
- Title (PL)
- Oprawy oświetleniowe — Część 2-21: Wymagania szczegółowe — Węże świetlne
- Title (EN)
- Luminaires — Part 2-21: Particular requirements — Rope lights
Step-by-step procedure
-
Classification and marking
Class II or III, at least IP 44 outdoors (21.5); voltage and wattage of the rope light, "indoor use only" text or symbol, information on the packing or in the instructions (21.6).
-
Construction
No terminal blocks of 4.6 of Part 1; connectors according to Annex A with corrigendum AC; control units in non-flammable material, flasher units — IEC 61347-2-11, LED drivers — IEC 61347-2-13 (21.7.2–21.7.4).
-
Pull and torque
Pull of 60 N 45 times for 1 s, then torque of 0,15 Nm for 1 min; conductors without noticeable movement in the terminals, pipe undamaged (21.7.5 a)).
-
Winding of a flexible pipe
1 m specimen on a 150 mm cylinder with 60 N: 10 times at 25 °C ± 2 °C, and with a degree of protection over X0 also 10 times at –15 °C ± 2 °C after 16 h of conditioning (21.7.5 b) 3)).
-
Bending in the cold
Winding on a mandrel of 4–5 specimen diameters, 16 h at –15 °C ± 2 °C, two turns around the mandrel in the cabinet — no cracks (21.7.5 b) 4)).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Device for winding a flexible pipe (Figure 1, 21.7.5 b) 3)) | Wooden cylinder of 150 mm diameter, 60 N weight, 1 000 mm specimen | — |
| Low-temperature cabinet –15 °C ± 2 °C (21.7.5 b) 3), 4)) | Conditioning for 16 h | — |
| Mandrel of 4–5 times the specimen diameter (Figure 2, 21.7.5 b) 4)) | Corresponds to Figure 1 of IEC 60811-504:2012 | — |
| Devices for a pull of 60 N and a torque of 0,15 Nm (21.7.5 a)) | Loading without jerks | — |
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN 60598-2-21:2015-07 (English version, published 09-07-2015; implements EN 60598-2-21:2015 and IEC 60598-2-21:2014 [IDT]) with corrigendum PN-EN 60598-2-21:2015-07/AC:2017-03 — “Luminaires — Part 2-21: Particular requirements — Rope lights”.
How does this method work?
The rope light is tested according to IEC 60598-1 in the order listed in Part 2-21: the class (only II or III) and IP degree (at least IP 44 outdoors), marking and instructions are checked, and the strength of the pipe — by a pull of 60 N 45 times for 1 s and a torque of 0,15 Nm for 1 min, a flexible pipe additionally by winding on a 150 mm cylinder with 60 N at 25 °C and –15 °C and by winding on a mandrel after 16 h at –15 °C, without cracks.
What is the measuring range and accuracy?
STATUS (as of 26.11.2026): PKN card: PN-EN 60598-2-21:2015-07 — English version (09-07-2015, 26 pages), KT 4 (lighting technology), implements EN 60598-2-21:2015 [IDT] and IEC 60598-2-21:2014 [IDT], directive 2014/35/EU; corrigendum AC:2017-03 (EN 60598-2-21:2015/AC:2017-01, IEC 60598-2-21:2014/COR1:2016); the card gives no withdrawal date.; Scope (21.1): rope lights with non-replaceable light sources, supply voltage up to 250 V, indoors and outdoors; Classification (21.5): Class II or III only; outdoor — at least IP 44; Pull on the pipe (21.7.5 a) 1)): 60 N on the ends of the pipe, 45 times without jerks, for 1 s each.
How long does the test take?
The times given for the individual stages add up to approximately 1 days 8 h 2 min. The procedure comprises 5 steps.
What equipment is required?
Device for winding a flexible pipe (Figure 1, 21.7.5 b) 3)), Low-temperature cabinet –15 °C ± 2 °C (21.7.5 b) 3), 4)), Mandrel of 4–5 times the specimen diameter (Figure 2, 21.7.5 b) 4)), Devices for a pull of 60 N and a torque of 0,15 Nm (21.7.5 a)).
Where is this test used?
Rope lights (sealed lighting chains) with non-replaceable light sources, indoors and outdoors, up to 250 V (21.1); Rigid and flexible rope lights — mechanical tests of the pipe (21.7.5); Rope lights interconnected into systems — connectors according to Annex A, marking of the maximum length and wattage (21.6.4, 21.7.3); Rope lights with ornamental attachments and control units (flasher units, LED drivers) (21.1, 21.7.4).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 60598-2-21.