💡 Extra-low-voltage lighting systems for ELV light sources: particular requirements — class III luminaires, SELV up to 25 V AC or 60 V DC, current up to 25 A, test of the supporting conductors with five times the mass of the luminaires (at least 10 kg, 1 h, deflection ≤ 10 %), voltage drop at movable contacts ≤ 50 mV, temperature of bare conductors ≤ 70 °C; PN-EN IEC 60598-2-23

Electronics and EMC PN-EN IEC 60598-2-23

In short

Particular requirements for complete extra-low-voltage (ELV) lighting systems for ordinary interior use, in which luminaires connected in parallel are supplied via freely suspended continuous supporting conductors or profiles and the current in the ELV part does not exceed 25 A. The test is performed according to PN-EN IEC 60598-2-23:2021-06 (English version, published 14-06-2021, and Polish version, published 11-12-2025; implements EN IEC 60598-2-23:2021 and IEC 60598-2-23:2020 [IDT]); STATUS (as of 24.11.2026): PKN cards: PN-EN IEC 60598-2-23:2021-06 — English version (published 14-06-2021, 24 pages) and Polish version (published 11-12-2025, 20 pages), KT 4 (lighting technology), implements EN IEC 60598-2-23:2021 [IDT] and IEC 60598-2-23:2020 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-23:2005 (Polish version); the cards give no withdrawal date. The procedure comprises 5 steps (about 1 h 1 min in total); it is used for: Extra-low-voltage lighting systems in kit form for ordinary interior use, with luminaires supplied via supporting conductors or profiles (23.1, 23.3.1), Strength test of supporting conductors and luminaire connectors, also with pin or edge contacts penetrating the insulation (23.7.4, 23.7.5, 23.10.1), Checking the safety isolating transformers and convertors supplied with the system (IEC 61558-2-6, IEC 61558-2-16, IEC 61347-2-2, IEC 61347-2-13) (23.7.2, 23.7.3).

At a glance

  • Standard: PN-EN IEC 60598-2-23:2021-06 (English version, published 14-06-2021, and Polish version, published 11-12-2025; implements EN IEC 60598-2-23:2021 and IEC 60598-2-23:2020 [IDT])
  • Category: Electronics and EMC
  • Procedure steps: 5
  • Total time of stages: 1 h 1 min
  • STATUS (as of 24.11.2026): PKN cards: PN-EN IEC 60598-2-23:2021-06 — English version (published 14-06-2021, 24 pages) and Polish version (published 11-12-2025, 20 pages), KT 4 (lighting technology), implements EN IEC 60598-2-23:2021 [IDT] and IEC 60598-2-23:2020 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-23:2005 (Polish version); the cards give no withdrawal date.
  • Scope (23.1): ELV systems for ordinary interior use, supply voltage ≤ 1 000 V, current in the ELV part ≤ 25 A, luminaires connected in parallel
  • Class of luminaires (23.5): class III

Overview

WHAT THE STANDARD COVERS. According to 23.1 of IEC 60598-2-23:2020 the standard specifies requirements for extra-low-voltage lighting systems for ELV light sources, intended for ordinary interior use on supply voltages not exceeding 1 000 V. The luminaires, connected in parallel, are supplied via freely suspended continuous supporting conductors or profiles, and the current in the ELV part of the system does not exceed 25 A. The system is, according to 23.3.1, a lighting system in kit form: a transformer/convertor or controlgear, supporting conductors and luminaires with all the necessary fixing devices and electrical and mechanical connectors. A supporting conductor (23.3.2) is a conductive span wire or profile spanned between the main supports, supplying the luminaires and carrying their mass; the definitions also cover the main support, auxiliary support, spacer, connector for supporting conductor and luminaire connector (23.3.3–23.3.7). The standard is used together with IEC 60598-1; the tests from the appropriate sections of Part 1 are carried out in the order listed in Part 2-23, and type tests are carried out on the complete system as provided by the manufacturer (23.4).

ACCORDING TO THE TEXT OF IEC 60598-2-23:2020 (second edition; the publisher's sample covers the foreword and 23.1–23.13.2). The standard was prepared by subcommittee IEC SC 34D (luminaires) of IEC TC 34. The second edition replaces the first edition of 1996 and Amendment 1 of 2000; according to the foreword the title and scope were changed to include other light sources, references (including those to transformer and controlgear standards) were updated, and the short-circuit test (former 23.7.6.1 and 23.7.6.2) was replaced by a reference to the same test in Part 1 (no major technical changes, Annex A). Normative references: IEC TR 60083, IEC 60598-1, IEC 61347-2-2, IEC 61347-2-13, IEC 61558-2-6 and IEC 61558-2-16.

CLASSIFICATION AND INSTRUCTIONS (23.5, 23.6). Luminaires in ELV lighting systems are class III. The system is accompanied by installation instructions with a complete list of parts (number and type of each part) stating among other things: how the system is mounted, the maximum permitted distance between main supports and the spacing of auxiliary supports; any special requirements for an existing mains installation (socket-outlets, switches, dimmers); that the supporting conductors of different systems shall not come into contact; that the system shall not be extended beyond the number of luminaires of the set and that no parts other than those assigned by the manufacturer nor additional attachments, e.g. decorative ones, shall be used; the warning “WARNING – To avoid the risk of overheating and fire, do not bridge the conductors”; the positions or spacings for the connection of luminaires.

CONSTRUCTION (23.7). The set delivered by the manufacturer includes the transformer or convertor/controlgear; the secondary side complies with SELV (23.7.1). Transformers and power supply units — safety isolating type (IEC 61558-2-6 or IEC 61558-2-16), and convertors/controlgear — safety isolating type according to IEC 61347-2-2 or IEC 61347-2-13, with a rated output voltage not exceeding 25 V RMS or 60 V ripple-free DC (23.7.2, 23.7.3). Supporting conductors shall be continuous and support five times the mass of the connected luminaires with their light sources (23.7.4): at the mid-point of the maximum span a load equal to five times the weight of the luminaires and lamps of the set, at least 10 kg, is applied at 90° simultaneously to both conductors for 1 h; after removal of the load the deflection from the normal position shall not exceed 10 % of the distance between the supporting conductors measured before loading. If the system uses pin contacts or edge contacts, the supporting conductors are first subjected to 25 piercings at different places. Luminaire connectors shall support five times the mass of the luminaire with its light source without permanent deformation — test of 4.14.1 of Part 1 with a load of at least 1,5 kg, after the test of 23.10.1 if applicable (23.7.5). Protection against short-circuiting of uninsulated accessible SELV conductors of opposite polarity is checked by the test of 4.26.2 of Part 1 (23.7.6). Electrical connections to supporting conductors shall not be subject to mechanical tension (23.7.9), the system shall be insulated from the supporting structure (23.7.10), and the rated current of the system is limited to 25 A (23.7.11).

TERMINALS AND CONNECTIONS (23.10). Luminaire connectors may be connected to the supporting conductor by pin or edge contacts penetrating the insulation; this is checked by the test of 23.7.5 after that of 23.7.4 (23.10.1). A plug of the supporting conductor for the transformer/convertor shall not be interchangeable with plugs and socket-outlets according to IEC TR 60083 (23.10.2). Good contact shall be maintained at all movable electrical contact points (23.10.3): the luminaire or movable contact, with all parts giving a mechanical and electrical load to the contact, is placed in five positions according to the manufacturer's instructions, a current of 1,5 times the rated current is passed through each connection and after 1 min the voltage drop in each position shall not exceed 50 mV.

PROTECTION AGAINST ELECTRIC SHOCK AND THERMAL TESTS (23.12, 23.13). The supply voltage of the supporting conductors does not exceed 25 V RMS for alternating current and 60 V ripple-free for direct current. Normal operation is tested at 1,06 times the nominal supply voltage (or 1,06 times the mean of the range), except for transformers/convertors marked t w /t c, tested at the nominal voltage; the surface temperature of bare conductors in the output circuit shall not exceed 70 °C, and of insulated conductors the temperature permitted for their insulation (23.13.1). In the abnormal operation test the system is operated at 0,9 to 1,1 times the nominal supply voltage (or range), whichever gives the highest temperatures at the parts of Tables 12.3–12.5 of Part 1; points in the secondary circuit where short circuits can occur are short-circuited (with the lamps completely inserted in the lampholders), and the surface temperature of the output circuit conductors shall not exceed the values found in normal operation by more than 10 K (23.13.2).

WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. The supporting conductor test is done at the mid-point of the MAXIMUM span, on both conductors simultaneously, with a load of at least 10 kg, and for contacts penetrating the insulation — after 25 piercings; the voltage drop is measured in five positions at 1,5 times the rated current only after 1 min; in normal operation the voltage of 1,06 times nominal does not apply to transformers marked t w /t c.

WHAT WE DO NOT GIVE HERE. The clauses from 23.14 on (resistance to dust and moisture, insulation resistance and electric strength, resistance to heat, fire and tracking) and Annex A — the sample ends at 23.13.2; the Part 1 tests (4.14.1, 4.26.2, Section 12) are not reproduced — they are in IEC 60598-1.

STATUS (as of 24.11.2026). PKN cards: PN-EN IEC 60598-2-23:2021-06 “Oprawy oświetleniowe -- Część 2-23: Wymagania szczegółowe -- Systemy oświetleniowe bardzo niskiego napięcia do źródeł światła ELV” — English version (published 14-06-2021, 24 pages) and Polish version (published 11-12-2025, 20 pages), KT 4 (lighting technology), implements EN IEC 60598-2-23:2021 [IDT] and IEC 60598-2-23:2020 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-23:2005 (Polish version); the cards give no withdrawal date.

Method principle

The complete ELV system (transformer or convertor, supporting conductors, class III luminaires) is tested according to IEC 60598-1 with the requirements of Part 2-23: strength of the supporting conductors (five times the mass of the luminaires, at least 10 kg, 1 h, deflection ≤ 10 % of the spacing) and of the luminaire connectors, voltage drop at movable contacts at 1,5 times the rated current (≤ 50 mV after 1 min) and the temperature of the output circuit conductors (bare ≤ 70 °C in normal operation, increase ≤ 10 K in abnormal operation).

Applications

Key parameters

ParameterValue
STATUS (as of 24.11.2026)PKN cards: PN-EN IEC 60598-2-23:2021-06 — English version (published 14-06-2021, 24 pages) and Polish version (published 11-12-2025, 20 pages), KT 4 (lighting technology), implements EN IEC 60598-2-23:2021 [IDT] and IEC 60598-2-23:2020 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-23:2005 (Polish version); the cards give no withdrawal date.
Scope (23.1)ELV systems for ordinary interior use, supply voltage ≤ 1 000 V, current in the ELV part ≤ 25 A, luminaires connected in parallel
Class of luminaires (23.5)class III
Output voltage (23.7.2, 23.7.3, 23.12)≤ 25 V RMS or ≤ 60 V ripple-free DC; secondary side SELV
Supporting conductors (23.7.4)load 5 × weight of the luminaires with light sources, at least 10 kg, at 90° at the mid-point of the maximum span, both conductors, 1 h; deflection after the test ≤ 10 % of the conductor spacing; with penetrating contacts — 25 piercings beforehand
Luminaire connectors (23.7.5)5 × mass of the luminaire with light source without permanent deformation; test 4.14.1 of Part 1, at least 1,5 kg
Movable contacts (23.10.3)5 positions, current 1,5 × rated, voltage drop ≤ 50 mV in each position after 1 min
Temperatures (23.13)normal operation at 1,06 × nominal voltage: bare output circuit conductors ≤ 70 °C; abnormal operation at 0,9–1,1 × voltage: increase ≤ 10 K over normal operation

Standard

Standard number
PN-EN IEC 60598-2-23:2021-06 (English version, published 14-06-2021, and Polish version, published 11-12-2025; implements EN IEC 60598-2-23:2021 and IEC 60598-2-23:2020 [IDT])
Title (PL)
Oprawy oświetleniowe — Część 2-23: Wymagania szczegółowe — Systemy oświetleniowe bardzo niskiego napięcia do źródeł światła ELV
Title (EN)
Luminaires — Part 2-23: Particular requirements — Extra-low-voltage lighting systems for ELV light sources

Step-by-step procedure

  1. Complete system

    Type tests on the complete system provided by the manufacturer, in the order of Part 2-23; checking the parts list and the installation instructions with the warning against bridging the conductors (23.4, 23.6).

  2. Supporting conductors

    With pin or edge contacts — 25 piercings; load of 5 × weight of the luminaires (≥ 10 kg) at the mid-point of the maximum span on both conductors; after removing the load the deflection ≤ 10 % of the conductor spacing (23.7.4).

    ⏱ Time: 1 h

  3. Luminaire connectors

    Test 4.14.1 of Part 1, load of 5 × mass of the luminaire, at least 1,5 kg, without permanent deformation; after the test of 23.7.4 (23.7.5, 23.10.1).

  4. Movable contacts

    Five positions according to the instructions, current 1,5 × rated through each connection, voltage drop ≤ 50 mV (23.10.3).

    ⏱ Time: 1 min in each position

  5. Thermal tests

    Normal operation at 1,06 × voltage (bare conductors ≤ 70 °C); abnormal operation at 0,9–1,1 × voltage with short-circuiting of points of the secondary circuit (increase ≤ 10 K) (23.13.1, 23.13.2).

Required equipment and apparatus

EquipmentExampleIndicative price
Load rig for supporting conductors (23.7.4)Load applied at 90° at the mid-point of the maximum span simultaneously to both conductors, for 1 h—
Current source and voltage-drop meter (23.10.3)Current of 1,5 times the rated current through each connection; voltage drop read after 1 min—
Adjustable supply (23.13)1,06 × nominal voltage in normal operation; 0,9–1,1 × voltage in abnormal operation—
Conductor surface temperature measurement (23.13)Bare output circuit conductors — limit 70 °C—

Health and safety (OHS)

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-EN IEC 60598-2-23:2021-06 (English version, published 14-06-2021, and Polish version, published 11-12-2025; implements EN IEC 60598-2-23:2021 and IEC 60598-2-23:2020 [IDT]) — “Luminaires — Part 2-23: Particular requirements — Extra-low-voltage lighting systems for ELV light sources”.

How does this method work?

The complete ELV system (transformer or convertor, supporting conductors, class III luminaires) is tested according to IEC 60598-1 with the requirements of Part 2-23: strength of the supporting conductors (five times the mass of the luminaires, at least 10 kg, 1 h, deflection ≤ 10 % of the spacing) and of the luminaire connectors, voltage drop at movable contacts at 1,5 times the rated current (≤ 50 mV after 1 min) and the temperature of the output circuit conductors (bare ≤ 70 °C in normal operation, increase ≤ 10 K in abnormal operation).

What is the measuring range and accuracy?

STATUS (as of 24.11.2026): PKN cards: PN-EN IEC 60598-2-23:2021-06 — English version (published 14-06-2021, 24 pages) and Polish version (published 11-12-2025, 20 pages), KT 4 (lighting technology), implements EN IEC 60598-2-23:2021 [IDT] and IEC 60598-2-23:2020 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-23:2005 (Polish version); the cards give no withdrawal date.; Scope (23.1): ELV systems for ordinary interior use, supply voltage ≤ 1 000 V, current in the ELV part ≤ 25 A, luminaires connected in parallel; Class of luminaires (23.5): class III; Output voltage (23.7.2, 23.7.3, 23.12): ≤ 25 V RMS or ≤ 60 V ripple-free DC; secondary side SELV.

How long does the test take?

The times given for the individual stages add up to approximately 1 h 1 min. The procedure comprises 5 steps.

What equipment is required?

Load rig for supporting conductors (23.7.4), Current source and voltage-drop meter (23.10.3), Adjustable supply (23.13), Conductor surface temperature measurement (23.13).

Where is this test used?

Extra-low-voltage lighting systems in kit form for ordinary interior use, with luminaires supplied via supporting conductors or profiles (23.1, 23.3.1); Strength test of supporting conductors and luminaire connectors, also with pin or edge contacts penetrating the insulation (23.7.4, 23.7.5, 23.10.1); Checking the safety isolating transformers and convertors supplied with the system (IEC 61558-2-6, IEC 61558-2-16, IEC 61347-2-2, IEC 61347-2-13) (23.7.2, 23.7.3); Measurement of the voltage drop at movable contacts and of the temperature of the output circuit conductors (23.10.3, 23.13).

What safety precautions apply?

According to 23.6 f) the installation instructions must contain the warning: to avoid the risk of overheating and fire, do not bridge the conductors.

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN IEC 60598-2-23.

🔍 Find a laboratory performing this test