⚡ Ageing of cable insulation and sheaths in an air oven (8 to 20 complete air changes per hour) — test pieces suspended vertically at least 20 mm apart, not more than 2 % of the oven volume, after ageing at least 16 h at ambient temperature; variation of tensile strength and elongation at break or bending test on cores; PN-EN 60811-401
In short
Ageing in an air oven is used for crosslinked and thermoplastic insulating and sheathing compounds of cables: five test pieces prepared according to IEC 60811-501 are kept in an oven with 8 to 20 complete air changes per hour at the temperature and for the time given in the cable product standard, and after at least 16 h at ambient temperature their tensile strength and elongation at break are tested. The test is performed according to PN-EN 60811-401:2012 (Polish version; implements EN 60811-401:2012 and IEC 60811-401:2012 [IDT]) with amendment PN-EN 60811-401:2012/A1:2018-02 (Polish version; implements EN 60811-401:2012/A1:2017 and IEC 60811-401:2012/AMD1:2017 [IDT]); Arrangement of test pieces (4.2.3.2): 5 test pieces vertically in the middle of the oven, at least 20 mm apart, not more than 2 % of the oven volume (wording of edition 1.0 — clause changed by A1:2017, we have not read the text after the amendment). The procedure comprises 5 steps (about 16 h in total); it is used for: Crosslinked and thermoplastic insulating and sheathing compounds of cables (clause 1), Test pieces of insulating or sheathing material, test pieces of cores, pieces of completed cable; combination with the loss of mass test according to IEC 60811-409 (4.1), Circular cores up to 16 mm² from which the conductor cannot be removed after ageing — bending test on a mandrel (4.3).
At a glance
- Standard: PN-EN 60811-401:2012 (Polish version; implements EN 60811-401:2012 and IEC 60811-401:2012 [IDT]) with amendment PN-EN 60811-401:2012/A1:2018-02 (Polish version; implements EN 60811-401:2012/A1:2017 and IEC 60811-401:2012/AMD1:2017 [IDT])
- Category: Electronics and EMC
- Procedure steps: 5
- Total time of stages: 16 h
- STATUS (as of 22.11.2026): PKN cards: PN-EN 60811-401:2012 (Polish version, published 21-11-2022, 22 pages, KT 53, implements EN 60811-401:2012 and IEC 60811-401:2012 [IDT], replaces PN-EN 60811-1-2:1999 and its amendment A2:2002) and amendment PN-EN 60811-401:2012/A1:2018-02 (Polish version, published 05-12-2022, changes 4.1, 4.2.2, 4.2.3.2–4.2.3.4, 4.3.3 and Annex C); the cards give no withdrawal date.
- Air exchange (4.2.1): not less than 8 and not more than 20 complete air changes per hour at the ageing temperature
- Fan in the oven (4.2.1): only for rubber compounds (unless the cable specification states otherwise); in case of dispute without a fan
Overview
WHAT THE STANDARD COVERS. According to clause 1 of IEC 60811-401:2012 the standard specifies the procedure for ageing in an air oven, which typically applies to crosslinked and thermoplastic compounds used for insulating and sheathing materials. Ageing may be required by the cable product standard for: a) prepared test pieces of insulating or sheathing material only, b) prepared test pieces of cores (conductor and insulation), c) test pieces of completed cable, d) the loss of mass test (IEC 60811-409); ageing a) or b) and test d) may be combined on the same test pieces when the ageing time and temperature are the same.
ACCORDING TO THE TEXT OF IEC 60811-401:2012 (edition 1.0, 2012-03; publisher's sample: clauses 1–4 and Annex A, method 1). The standard was prepared by IEC TC 20 (electric cables) and is used in conjunction with IEC 60811-100:2012, which we have not read. It applies with amendment AMD1:2017; according to the PKN card, amendment PN-EN 60811-401:2012/A1:2018-02 changes clauses 4.1, 4.2.2, 4.2.3.2, 4.2.3.3, 4.2.3.4, 4.3.3 and Annex C — we have not read their wording after the amendment (the preview of the consolidated version IEC 60811-401:2012+AMD1:2017 CSV ends at 4.1), so the description below reflects the text of edition 1.0.
OVEN (4.2.1). Ageing is carried out in an oven with natural air flow or air flow by pressure; the air shall flow over the surface of the test pieces and leave near the top of the oven. The oven shall have not less than 8 and not more than 20 complete air changes per hour at the ageing temperature (two methods of measuring air flow in Annex A). A fan rotating inside the oven is allowed only for rubber compounds, unless the cable specification states otherwise; in cases of dispute rubber compounds are also tested in an oven without a fan.
PROCEDURE (4.2.2–4.2.4). The test pieces — dumb-bells or tubes according to IEC 60811-501 — are taken as close as possible to the test pieces for the test without ageing. The test is carried out not less than 16 h after extrusion or cross-linking of the compound. Compounds of obviously different compositions are not aged at the same time in the same oven. Five test pieces are suspended vertically substantially in the middle of the oven, each at least 20 mm from any other; the test pieces shall not occupy more than 2 % of the oven volume. The ageing temperature and time are given in the cable product standard. After ageing the test pieces are left for at least 16 h at ambient temperature, avoiding direct sunlight, and their mechanical properties are then determined according to IEC 60811-501. Pieces of completed cable (three test pieces) and cores with conductors above 16 mm² are aged according to 4.2.3.3–4.2.3.4 and Annexes B and C.
RESULT (4.2.5–4.2.6). Variation of tensile strength VT = (TE − TU)/TU × 100 and variation of elongation at break VE = (EE − EU)/EU × 100, in per cent, where E is the aged test piece and U the untreated one (kept at room temperature). The variation between the median value of the aged test pieces and the median value of the untreated ones shall not exceed the percentage given in the cable product standard.
BENDING TEST (4.3). For circular cores up to and including 16 mm² when the conductor and separator cannot be removed without damaging the insulation (in case of dispute this procedure is decisive): two test pieces from each core, after ageing and at least 16 h at room temperature, are bent at ambient temperature around a mandrel to form a close helix, at a rate of about one turn in 5 s. Mandrel diameter = f × core diameter; Table 1: cross-section up to 2,5 mm² — f = 1 ± 0,1, 7 turns; 4 and 6 mm² — f = 2 ± 0,1, 6 turns; 10 and 16 mm² — f = 4 ± 0,1, 5 turns. The insulation of both test pieces, examined on the mandrel with normal or corrected vision without magnification, shall show no cracks; cracks in the first and last turns are disregarded.
AIR FLOW (Annex A, method 1). Indirect method: the average heating power needed to maintain the oven temperature with the ports open (P1) and closed (P2) is measured over at least 30 min each; the difference between oven and room temperature in both measurements shall agree to within 0,2 °C. Air volume V = 3 590 (P1 − P2) / [d (t2 − t1)] in litres per hour, where d is the density of air in g/l, t1 the room temperature and t2 the oven temperature.
WHAT WE DO NOT GIVE HERE. We do not reproduce the wording of the clauses changed by AMD1:2017 (list above), method 2 of air-flow measurement with a flowmeter, Annexes B and C (preparation of test pieces with conductor and of pieces of completed cable) or the requirements of IEC 60811-100, because we have not read them; the standard gives no ageing temperatures and times — they are in the cable product standards.
STATUS (as of 22.11.2026). PKN cards: PN-EN 60811-401:2012 “Kable i przewody elektryczne oraz światłowodowe -- Metody badań materiałów niemetalowych -- Część 401: Badania różne -- Metody starzenia cieplnego -- Starzenie w komorze cieplnej z obiegiem powietrza” — Polish version, published 21-11-2022, 22 pages, KT 53 (cables and wires), implements EN 60811-401:2012 [IDT] and IEC 60811-401:2012 [IDT], replaces PN-EN 60811-1-2:1999 and PN-EN 60811-1-2:1999/A2:2002 (Polish versions); PN-EN 60811-401:2012/A1:2018-02 — Polish version, published 05-12-2022, 5 pages, implements EN 60811-401:2012/A1:2017 [IDT] and IEC 60811-401:2012/AMD1:2017 [IDT]. Neither card gives a withdrawal date.
Method principle
Test pieces of insulation, sheath, cores or completed cable are kept in an air oven with controlled air exchange at the temperature and for the time given in the cable product standard, and their tensile strength and elongation at break are then compared with unaged test pieces (or the cores are bent around a mandrel and the insulation is examined for cracks).
Applications
- Crosslinked and thermoplastic insulating and sheathing compounds of cables (clause 1)
- Test pieces of insulating or sheathing material, test pieces of cores, pieces of completed cable; combination with the loss of mass test according to IEC 60811-409 (4.1)
- Circular cores up to 16 mm² from which the conductor cannot be removed after ageing — bending test on a mandrel (4.3)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 22.11.2026) | PKN cards: PN-EN 60811-401:2012 (Polish version, published 21-11-2022, 22 pages, KT 53, implements EN 60811-401:2012 and IEC 60811-401:2012 [IDT], replaces PN-EN 60811-1-2:1999 and its amendment A2:2002) and amendment PN-EN 60811-401:2012/A1:2018-02 (Polish version, published 05-12-2022, changes 4.1, 4.2.2, 4.2.3.2–4.2.3.4, 4.3.3 and Annex C); the cards give no withdrawal date. |
| Air exchange (4.2.1) | not less than 8 and not more than 20 complete air changes per hour at the ageing temperature |
| Fan in the oven (4.2.1) | only for rubber compounds (unless the cable specification states otherwise); in case of dispute without a fan |
| Arrangement of test pieces (4.2.3.2) | 5 test pieces vertically in the middle of the oven, at least 20 mm apart, not more than 2 % of the oven volume (wording of edition 1.0 — clause changed by A1:2017, we have not read the text after the amendment) |
| Time before and after ageing (4.2.3) | not less than 16 h after extrusion or cross-linking; after ageing at least 16 h at ambient temperature without sunlight (wording of edition 1.0 — clauses 4.2.3.2–4.2.3.4 changed by A1:2017, we have not read the text after the amendment) |
| Result (4.2.5) | VT = (TE − TU)/TU × 100 and VE = (EE − EU)/EU × 100, in %; variation of the medians not greater than in the product standard (4.2.6) |
| Bending test — Table 1 (4.3.3) | up to 2,5 mm²: f = 1 ± 0,1, 7 turns; 4 and 6 mm²: f = 2 ± 0,1, 6 turns; 10 and 16 mm²: f = 4 ± 0,1, 5 turns; about 1 turn in 5 s (wording of edition 1.0 — clause 4.3.3 changed by A1:2017, we have not read the text after the amendment) |
| Air flow — method 1 (A.1) | V = 3 590 (P1 − P2) / [d (t2 − t1)], l/h; power measurements over at least 30 min, temperature difference agreeing to 0,2 °C |
Standard
- Standard number
- PN-EN 60811-401:2012 (Polish version; implements EN 60811-401:2012 and IEC 60811-401:2012 [IDT]) with amendment PN-EN 60811-401:2012/A1:2018-02 (Polish version; implements EN 60811-401:2012/A1:2017 and IEC 60811-401:2012/AMD1:2017 [IDT])
- Title (PL)
- Kable i przewody elektryczne oraz światłowodowe — Metody badań materiałów niemetalowych — Część 401: Badania różne — Metody starzenia cieplnego — Starzenie w komorze cieplnej z obiegiem powietrza
- Title (EN)
- Electric and optical fibre cables — Test methods for non-metallic materials — Part 401: Miscellaneous tests — Thermal ageing methods — Ageing in an air oven
Step-by-step procedure
-
Test pieces
Dumb-bells or tubes according to IEC 60811-501, taken close to the test pieces for the test without ageing; not less than 16 h after extrusion or cross-linking (4.2.2, 4.2.3.1).
-
Ageing
Five test pieces vertically in the middle of the oven, at least 20 mm apart, not more than 2 % of the volume; no compounds of obviously different composition in the same oven; temperature and time from the product standard (4.2.3.2).
-
Rest
At least 16 h at ambient temperature, avoiding direct sunlight (4.2.3.2).
-
Mechanical test
Tensile strength and elongation at break according to IEC 60811-501 (4.2.4).
-
Result
Variations VT and VE in per cent; comparison of the medians with the unaged test pieces and with the requirement of the product standard (4.2.5, 4.2.6).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Air oven (4.2.1) | Natural air flow or air flow by pressure, the air flows over the test pieces and leaves near the top; 8 to 20 complete air changes per hour | — |
| Bending test apparatus (4.3.1) | Mandrel with a diameter of f × core diameter; apparatus of IEC 60811-504 | — |
| Wattmeter and stop-watch (A.1.3) | For measuring the average heating power when checking the air flow by method 1 | — |
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN 60811-401:2012 (Polish version; implements EN 60811-401:2012 and IEC 60811-401:2012 [IDT]) with amendment PN-EN 60811-401:2012/A1:2018-02 (Polish version; implements EN 60811-401:2012/A1:2017 and IEC 60811-401:2012/AMD1:2017 [IDT]) — “Electric and optical fibre cables — Test methods for non-metallic materials — Part 401: Miscellaneous tests — Thermal ageing methods — Ageing in an air oven”.
How does this method work?
Test pieces of insulation, sheath, cores or completed cable are kept in an air oven with controlled air exchange at the temperature and for the time given in the cable product standard, and their tensile strength and elongation at break are then compared with unaged test pieces (or the cores are bent around a mandrel and the insulation is examined for cracks).
What is the measuring range and accuracy?
STATUS (as of 22.11.2026): PKN cards: PN-EN 60811-401:2012 (Polish version, published 21-11-2022, 22 pages, KT 53, implements EN 60811-401:2012 and IEC 60811-401:2012 [IDT], replaces PN-EN 60811-1-2:1999 and its amendment A2:2002) and amendment PN-EN 60811-401:2012/A1:2018-02 (Polish version, published 05-12-2022, changes 4.1, 4.2.2, 4.2.3.2–4.2.3.4, 4.3.3 and Annex C); the cards give no withdrawal date.; Air exchange (4.2.1): not less than 8 and not more than 20 complete air changes per hour at the ageing temperature; Fan in the oven (4.2.1): only for rubber compounds (unless the cable specification states otherwise); in case of dispute without a fan; Arrangement of test pieces (4.2.3.2): 5 test pieces vertically in the middle of the oven, at least 20 mm apart, not more than 2 % of the oven volume (wording of edition 1.0 — clause changed by A1:2017, we have not read the text after the amendment).
How long does the test take?
The times given for the individual stages add up to approximately 16 h. The procedure comprises 5 steps.
What equipment is required?
Air oven (4.2.1), Bending test apparatus (4.3.1), Wattmeter and stop-watch (A.1.3).
Where is this test used?
Crosslinked and thermoplastic insulating and sheathing compounds of cables (clause 1); Test pieces of insulating or sheathing material, test pieces of cores, pieces of completed cable; combination with the loss of mass test according to IEC 60811-409 (4.1); Circular cores up to 16 mm² from which the conductor cannot be removed after ageing — bending test on a mandrel (4.3).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 60811-401.