🔩 Longitudinal reversion of thermoplastics pipes with smooth walls and wall thickness up to 16 mm — pipe piece in a liquid bath (reference method in case of dispute) or in an air oven at a specified temperature for a specified time, change in the marked length as a percentage of the initial length; PN-EN ISO 2505

Materials and NDT PN-EN ISO 2505

In short

The longitudinal reversion of thermoplastics pipes is determined by placing a pipe piece in a liquid bath or an air oven at a specified temperature for a specified time and measuring a marked length before and after heating under identical conditions; the result is the change in length as a percentage of the initial length. The test is performed according to PN-EN ISO 2505:2024-04 (Polish version; implements EN ISO 2505:2023 and ISO 2505:2023 [IDT]); STATUS (as of 23.11.2026): PKN card: PN-EN ISO 2505:2024-04 — Polish version, published 07-10-2025, 14 pages, KT 140, implements EN ISO 2505:2023 [IDT] and ISO 2505:2023 [IDT], replaces PN-EN ISO 2505:2006 (Polish version); the card gives no withdrawal date. The procedure comprises 5 steps; it is used for: Thermoplastics pipes with smooth internal and external walls and constant cross-section, with a wall thickness up to 16 mm (clause 1), Materials listed in clause 4: among them PVC-U, PVC-C, PE 80, PE 100, PE-X, PE-RT, PP-R, PP-H, PB, ABS, PA-U, Not applicable to non-smooth structured-wall pipes (clause 1).

At a glance

  • Standard: PN-EN ISO 2505:2024-04 (Polish version; implements EN ISO 2505:2023 and ISO 2505:2023 [IDT])
  • Category: Materials and NDT
  • Procedure steps: 5
  • STATUS (as of 23.11.2026): PKN card: PN-EN ISO 2505:2024-04 — Polish version, published 07-10-2025, 14 pages, KT 140, implements EN ISO 2505:2023 [IDT] and ISO 2505:2023 [IDT], replaces PN-EN ISO 2505:2006 (Polish version); the card gives no withdrawal date.
  • Scope (clause 1): pipes with smooth walls and constant cross-section, wall thickness ≤ 16 mm; not non-smooth structured-wall pipes
  • Medium (clause 1, 6.1–6.2): liquid bath (reference in case of dispute) or air oven

Overview

WHAT THE STANDARD COVERS. According to clause 1 of ISO 2505:2023 the standard specifies a method for determining the longitudinal reversion of thermoplastics pipes, carried out in either a liquid or in air; in case of dispute heated liquid is the reference. It applies to all thermoplastics pipes with smooth internal and external walls of constant cross-section; it does not apply to non-smooth structured-wall pipes. The method applies to pipes with a wall thickness not greater than 16 mm. The parameters appropriate to the pipe material and the recommended maximum levels of reversion as a function of the material are given in Annex A.

ACCORDING TO THE TEXT OF ISO 2505:2023 (edition 4, published 13.10.2023 according to the iTeh card; the publisher's sample covers the foreword and clauses 1–6.3.1 — scope, references, abbreviations of materials, principle and the beginning of the apparatus — without Table 1, preparation of test pieces, procedure, calculation and Annex A). The standard was prepared by committee ISO/TC 138/SC 5. Clause 4 lists the abbreviations of the materials to which the parameters of the standard refer, among them ABS, ASA, PA-U, PB-H, PB-R, PE 32/40, PE 50/63, PE 80, PE 100, PE 100-RC, PE-RT, PE-UHMW, PE-X, PP-B, PP-H, PP-R, PP-RCT, PVC-C, PVC-U and PVC-HI.

PRINCIPLE (clause 5). A pipe piece of specified length is placed in a liquid bath or an air oven at a specified temperature for a specified time. A marked length of this piece is measured under identical conditions before and after heating. The reversion is calculated as the change in length as a percentage of the initial length. The surface appearance of the test piece shall not change after heating.

APPARATUS (6.1–6.3.1). Heated liquid bath, thermostatically controlled at the temperature TR according to Table 1, unless the referring standard specifies otherwise; the volume and agitation of the bath are to keep the temperature within the specified range when the test piece is immersed. The liquid should be stable at that temperature and not affect the plastics material — glycerine, glycol, mineral oil free from aromatic hydrocarbons or a solution of calcium chloride are suitable, but any other liquid meeting these requirements may be used. Air oven with a thermostat keeping the temperature TR according to Table 1 with a permissible deviation of ± 2 °C and re-establishing that temperature within 15 min of the introduction of the test pieces. Device holding the test pieces in the bath or the oven in accordance with clause 7.

WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. The length is measured before and after heating under IDENTICAL conditions (clause 5); a result from the oven is not equivalent to one from the bath in case of dispute — the liquid is the reference; the bath liquid must not affect the plastics material (6.1).

WHAT WE DO NOT GIVE HERE. The temperatures TR and heating times for the individual materials (Table 1), the dimensions and number of test pieces, the way the length is marked, the procedure (clauses 7–8), the formula and the test report (clauses 9–10) or the recommended maximum levels of reversion (Annex A) — the sample ends at 6.3.1, and we have not read these parts of the standard.

STATUS (as of 23.11.2026). PKN card: PN-EN ISO 2505:2024-04 “Rury z tworzyw termoplastycznych -- Skurcz wzdłużny -- Metoda badania i parametry” — Polish version, published 07-10-2025, 14 pages, KT 140 (plastics pipes, fittings and valves), implements EN ISO 2505:2023 [IDT] and ISO 2505:2023 [IDT], replaces PN-EN ISO 2505:2006 (Polish version); the card gives no withdrawal date.

Method principle

A pipe piece is heated in a liquid or in air at a specified temperature for a specified time, and a marked length is measured before and after heating under identical conditions; the reversion is the change in this length as a percentage of the initial length.

Applications

Key parameters

ParameterValue
STATUS (as of 23.11.2026)PKN card: PN-EN ISO 2505:2024-04 — Polish version, published 07-10-2025, 14 pages, KT 140, implements EN ISO 2505:2023 [IDT] and ISO 2505:2023 [IDT], replaces PN-EN ISO 2505:2006 (Polish version); the card gives no withdrawal date.
Scope (clause 1)pipes with smooth walls and constant cross-section, wall thickness ≤ 16 mm; not non-smooth structured-wall pipes
Medium (clause 1, 6.1–6.2)liquid bath (reference in case of dispute) or air oven
Temperature (6.1, 6.2)TR according to Table 1 unless the referring standard specifies otherwise; oven ± 2 °C, return to TR within 15 min of introducing the test pieces (we have not read Table 1)
Bath liquid (6.1)stable at the test temperature, inert to the plastics material: glycerine, glycol, mineral oil free from aromatic hydrocarbons, calcium chloride solution or another meeting these requirements
Result (clause 5)change in the marked length as a percentage of the initial length; surface appearance unchanged after heating

Standard

Standard number
PN-EN ISO 2505:2024-04 (Polish version; implements EN ISO 2505:2023 and ISO 2505:2023 [IDT])
Title (PL)
Rury z tworzyw termoplastycznych — Skurcz wzdłużny — Metoda badania i parametry
Title (EN)
Thermoplastics pipes — Longitudinal reversion — Test method and parameters

Step-by-step procedure

  1. Pipe piece

    Piece of specified length with a marked gauge length; dimensions and number of test pieces according to clause 7 of the standard (we have not read this part).

  2. Measurement before

    Measurement of the marked length (clause 5).

  3. Heating

    In a liquid bath or an air oven at the temperature TR and for the time from Table 1 or the referring standard (clause 5, 6.1–6.2).

    🌡 Temperature: TR according to Table 1

  4. Measurement after

    Measurement of the marked length under the same conditions as before heating (clause 5).

  5. Result

    Reversion = change in length as a percentage of the initial length; check that the surface appearance has not changed (clause 5).

Required equipment and apparatus

EquipmentExampleIndicative price
Liquid bath with thermostat (6.1)Temperature TR according to Table 1; volume and agitation keeping the temperature after immersion of the test piece—
Air oven with thermostat (6.2)TR ± 2 °C, temperature re-established within 15 min of introducing the test pieces—
Test piece holder (6.3.1)Holds the test pieces in the bath or the oven in accordance with clause 7—

Reagents, media and consumables

ReagentCASDetails
Bath liquid (6.1)—Glycerine, glycol, mineral oil free from aromatic hydrocarbons or calcium chloride solution — or another liquid stable at the test temperature and inert to the plastics material.

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-EN ISO 2505:2024-04 (Polish version; implements EN ISO 2505:2023 and ISO 2505:2023 [IDT]) — “Thermoplastics pipes — Longitudinal reversion — Test method and parameters”.

How does this method work?

A pipe piece is heated in a liquid or in air at a specified temperature for a specified time, and a marked length is measured before and after heating under identical conditions; the reversion is the change in this length as a percentage of the initial length.

What is the measuring range and accuracy?

STATUS (as of 23.11.2026): PKN card: PN-EN ISO 2505:2024-04 — Polish version, published 07-10-2025, 14 pages, KT 140, implements EN ISO 2505:2023 [IDT] and ISO 2505:2023 [IDT], replaces PN-EN ISO 2505:2006 (Polish version); the card gives no withdrawal date.; Scope (clause 1): pipes with smooth walls and constant cross-section, wall thickness ≤ 16 mm; not non-smooth structured-wall pipes; Medium (clause 1, 6.1–6.2): liquid bath (reference in case of dispute) or air oven; Temperature (6.1, 6.2): TR according to Table 1 unless the referring standard specifies otherwise; oven ± 2 °C, return to TR within 15 min of introducing the test pieces (we have not read Table 1).

How long does the test take?

The procedure comprises 5 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.

What equipment is required?

Liquid bath with thermostat (6.1), Air oven with thermostat (6.2), Test piece holder (6.3.1).

Where is this test used?

Thermoplastics pipes with smooth internal and external walls and constant cross-section, with a wall thickness up to 16 mm (clause 1); Materials listed in clause 4: among them PVC-U, PVC-C, PE 80, PE 100, PE-X, PE-RT, PP-R, PP-H, PB, ABS, PA-U; Not applicable to non-smooth structured-wall pipes (clause 1).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN ISO 2505.

🔍 Find a laboratory performing this test