🏗️ Curtain walling: calculation of thermal transmittance — single assessment method and component assessment method, glazing, opaque panels, frames, linear thermal bridges Ψ at junctions; PN-EN ISO 12631
In short
Method for calculating the thermal transmittance of curtain walls consisting of glazed and/or opaque panels fitted in, or connected to, frames. The test is performed according to PN-EN ISO 12631:2017-10 (English and Polish version; implements EN ISO 12631:2017 and ISO 12631:2017 [IDT]); STATUS (as of 19.11.2026): PKN cards: PN-EN ISO 12631:2017-10 “Cieplne właściwości użytkowe ścian osłonowych -- Obliczanie współczynnika przenikania ciepła” — English version (published 04-10-2017, 64 pages) and Polish version (published 18-10-2019, 58 pages), KT 179 Thermal Protection of Buildings, implements EN ISO 12631:2017 and ISO 12631:2017 [IDT], replaces PN-EN ISO 12631:2013-03 (English and Polish versions); the cards give no withdrawal date. The procedure comprises 4 steps; it is used for: Calculation of the thermal transmittance of unitised and stick curtain walls by curtain wall manufacturers (introduction, 5.3), Comparison of the thermal transmittance of different types of curtain walls and input data for building energy performance calculations (introduction), Walls with single or multiple glazing, low-emissivity coating, gas filling and opaque panels (clause 1).
At a glance
- Standard: PN-EN ISO 12631:2017-10 (English and Polish version; implements EN ISO 12631:2017 and ISO 12631:2017 [IDT])
- Category: Construction
- Procedure steps: 4
- STATUS (as of 19.11.2026): PKN cards: PN-EN ISO 12631:2017-10 “Cieplne właściwości użytkowe ścian osłonowych -- Obliczanie współczynnika przenikania ciepła” — English version (published 04-10-2017, 64 pages) and Polish version (published 18-10-2019, 58 pages), KT 179 Thermal Protection of Buildings, implements EN ISO 12631:2017 and ISO 12631:2017 [IDT], replaces PN-EN ISO 12631:2013-03 (English and Polish versions); the cards give no withdrawal date.
- Methods (introduction): single assessment method (clause 7); component assessment method (clause 8); selection — clause 6
- Not covered (clause 1): solar radiation, air leakage, condensation, shutters, corners and edges of the wall, connections to the building structure, integrated heating
Overview
WHAT THE STANDARD COVERS. According to clause 1 of ISO 12631:2017 the standard specifies a method for calculating the thermal transmittance of curtain walls consisting of glazed and/or opaque panels fitted in, or connected to, frames. The calculation includes different types of glazing (glass or plastic, single or multiple, with or without low-emissivity coating, cavities filled with air or other gases), frames of any material with or without thermal breaks and opaque panels clad with metal, glass, ceramics or any other material; thermal bridge effects at the rebate or connection between glazing, frame and panels are included. It does not include: solar radiation, heat transfer caused by air leakage, condensation, shutters, additional heat transfer at the corners and edges of the curtain walling, connections to the main building structure and through fixing lugs, and curtain walls with integrated heating.
ACCORDING TO THE TEXT OF ISO 12631:2017 (publisher's sample: contents, foreword, introduction, clauses 1–5.3.1). The standard was prepared by CEN/TC 89 in collaboration with ISO/TC 163/SC 2 (Vienna Agreement). The second edition replaces ISO 12631:2012: Annexes G and H were deleted (moved to the technical report) and the values in Annex D were checked. The standard belongs to the set of EPB standards on the energy performance of buildings (module M2–5 according to ISO 52000-1); the choices of methods and data are recorded using the template of Annex A, default choices are given in Annex B. The results are used to compare the thermal transmittance of different curtain walls or as input data for calculating the heat use of a building; the standard is not suitable for assessing condensation. Two methods: single assessment method (clause 7) and component assessment method (clause 8), selection — clause 6; calculation examples — ISO/TR 52022-2. Testing with the hot box according to ISO 12567-1:2010 is an alternative. Frame transmittance Uf — according to ISO 10077-2 or EN 12412-2 with Annex D; glazing Ug — according to ISO 10291, ISO 10292, ISO 10293 (without edge effects); interaction of frame and infill — linear thermal transmittance Ψ according to ISO 10077-2; connections to the building structure — ISO 10211.
PRINCIPLE (clause 5). The thermal transmittance of the curtain wall is calculated as a function of the thermal transmittances of its components (glazings, opaque panels, frames, mullions, transoms) and their geometrical characteristics plus the thermal interactions between them: lateral heat flow (linear thermal bridge) and surface and cavity thermal resistances (radiation and convection). The calculation procedure depends on the composition of the product.
CONTENT (table of contents). Annexes: A — input and method selection data sheet template, B — default choices, C — regional references, D — linear thermal transmittance of junctions, E — thermal effect of screws by a 2D numerical method according to ISO 10077-2, F — ventilated and unventilated air spaces; clause 9 — report (section drawings, overview drawing, values used, results). The content of clauses 6–9 and of the annexes is outside the sample.
STATUS (as of 19.11.2026). PKN cards: PN-EN ISO 12631:2017-10 “Cieplne właściwości użytkowe ścian osłonowych -- Obliczanie współczynnika przenikania ciepła” — English version (published 04-10-2017, 64 pages) and Polish version (published 18-10-2019, 58 pages), KT 179 Thermal Protection of Buildings, implements EN ISO 12631:2017 and ISO 12631:2017 [IDT], replaces PN-EN ISO 12631:2013-03 (English and Polish versions); the cards give no withdrawal date.
Method principle
The thermal transmittance of the curtain wall is calculated from the transmittances of its components (glazing Ug, opaque panels, frames Uf), their areas and lengths and the linear thermal transmittances Ψ at the junctions — by the single assessment method or the component assessment method.
Applications
- Calculation of the thermal transmittance of unitised and stick curtain walls by curtain wall manufacturers (introduction, 5.3)
- Comparison of the thermal transmittance of different types of curtain walls and input data for building energy performance calculations (introduction)
- Walls with single or multiple glazing, low-emissivity coating, gas filling and opaque panels (clause 1)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 19.11.2026) | PKN cards: PN-EN ISO 12631:2017-10 “Cieplne właściwości użytkowe ścian osłonowych -- Obliczanie współczynnika przenikania ciepła” — English version (published 04-10-2017, 64 pages) and Polish version (published 18-10-2019, 58 pages), KT 179 Thermal Protection of Buildings, implements EN ISO 12631:2017 and ISO 12631:2017 [IDT], replaces PN-EN ISO 12631:2013-03 (English and Polish versions); the cards give no withdrawal date. |
| Methods (introduction) | single assessment method (clause 7); component assessment method (clause 8); selection — clause 6 |
| Not covered (clause 1) | solar radiation, air leakage, condensation, shutters, corners and edges of the wall, connections to the building structure, integrated heating |
| Component data (introduction) | Uf — ISO 10077-2 or EN 12412-2 with Annex D; Ug — ISO 10291, 10292, 10293; Ψ — ISO 10077-2 |
| Alternative (introduction) | hot box test according to ISO 12567-1:2010 |
| Changes from 2012 (foreword) | Annexes G and H deleted; values in Annex D checked |
Standard
- Standard number
- PN-EN ISO 12631:2017-10 (English and Polish version; implements EN ISO 12631:2017 and ISO 12631:2017 [IDT])
- Title (PL)
- Cieplne właściwości użytkowe ścian osłonowych — Obliczanie współczynnika przenikania ciepła
- Title (EN)
- Thermal performance of curtain walling — Calculation of thermal transmittance
Step-by-step procedure
-
Input data and method selection
Data sheet according to the template of Annex A (default choices — Annex B); selection of the single or component assessment method (clause 6).
-
Geometry and components
Division of the wall into glazings, opaque panels, frames, mullions and transoms; Ug, Uf and panel transmittances (5.3, introduction).
-
Thermal bridges and calculation
Linear thermal transmittances Ψ at the junctions (Annex D, ISO 10077-2), calculation of the thermal transmittance of the wall (clause 7 or 8).
-
Report
Section drawings and overview drawing of the element, values used, results (clause 9).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| 2D numerical calculation software (Annex E) | Calculation of the thermal effect of screws and of Ψ values according to the procedures of ISO 10077-2 | — |
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN ISO 12631:2017-10 (English and Polish version; implements EN ISO 12631:2017 and ISO 12631:2017 [IDT]) — “Thermal performance of curtain walling — Calculation of thermal transmittance”.
How does this method work?
The thermal transmittance of the curtain wall is calculated from the transmittances of its components (glazing Ug, opaque panels, frames Uf), their areas and lengths and the linear thermal transmittances Ψ at the junctions — by the single assessment method or the component assessment method.
What is the measuring range and accuracy?
STATUS (as of 19.11.2026): PKN cards: PN-EN ISO 12631:2017-10 “Cieplne właściwości użytkowe ścian osłonowych -- Obliczanie współczynnika przenikania ciepła” — English version (published 04-10-2017, 64 pages) and Polish version (published 18-10-2019, 58 pages), KT 179 Thermal Protection of Buildings, implements EN ISO 12631:2017 and ISO 12631:2017 [IDT], replaces PN-EN ISO 12631:2013-03 (English and Polish versions); the cards give no withdrawal date.; Methods (introduction): single assessment method (clause 7); component assessment method (clause 8); selection — clause 6; Not covered (clause 1): solar radiation, air leakage, condensation, shutters, corners and edges of the wall, connections to the building structure, integrated heating; Component data (introduction): Uf — ISO 10077-2 or EN 12412-2 with Annex D; Ug — ISO 10291, 10292, 10293; Ψ — ISO 10077-2.
How long does the test take?
The procedure comprises 4 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.
What equipment is required?
2D numerical calculation software (Annex E).
Where is this test used?
Calculation of the thermal transmittance of unitised and stick curtain walls by curtain wall manufacturers (introduction, 5.3); Comparison of the thermal transmittance of different types of curtain walls and input data for building energy performance calculations (introduction); Walls with single or multiple glazing, low-emissivity coating, gas filling and opaque panels (clause 1).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN ISO 12631.