🔩 Structured-wall thermoplastics pipes — oven test: pieces of 300 mm ± 20 mm in an air-circulation oven (PVC-U and PP homopolymers 150 °C, PE 110 °C, PP random copolymers 135 °C), 30 min for a wall up to 10 mm or 60 min above, assessment of cracks, blisters and wall separation; PN-ISO 12091

Materials and NDT PN-ISO 12091

In short

Assessment of the wall homogeneity of structured-wall (non-smooth) thermoplastics pipes by heating in an oven. The test is performed according to PN-ISO 12091:2009 (Polish version; implements ISO 12091:1995 [IDT]); STATUS (PKN card as of 12.11.2026): PN-ISO 12091:2009 current (Polish version, published 20-05-2009); implements ISO 12091:1995; ISO 12091:1995 — published (iTeh). The procedure comprises 5 steps (about 1 h in total); it is used for: Structured-wall (non-smooth) thermoplastics pipes — pipe wall homogeneity (ISO 12091:1995, clause 1), Not for pipes with a smooth external surface; does not include longitudinal reversion (ISO 2505) (clause 1, note 1), Materials in Table A.1: PVC-U, PE, PP homopolymers and block copolymers, PP random copolymers.

At a glance

  • Standard: PN-ISO 12091:2009 (Polish version; implements ISO 12091:1995 [IDT])
  • Category: Materials and NDT
  • Procedure steps: 5
  • Total time of stages: 1 h
  • STATUS (PKN card as of 12.11.2026): PN-ISO 12091:2009 current (Polish version, published 20-05-2009); implements ISO 12091:1995; ISO 12091:1995 — published (iTeh)
  • Oven — condition (4.1): air circulation, thermostat ± 2 °C, temperature re-established in ≤ 15 min after insertion of the test pieces
  • Test piece — condition (5.2–5.3): 300 mm ± 20 mm; cut into 2 sections (dn ≤ 400 mm) or 4 (> 400 mm) according to the referring standard; ≥ 3 test pieces recommended

Overview

WHAT THE STANDARD COVERS. According to clause 1 of ISO 12091:1995 the standard specifies a method for assessing the pipe wall homogeneity of non-smooth, structured-wall thermoplastics pipes by inspection of the effects of heating in an oven; it does not apply to pipes with a smooth external surface. The test does not include longitudinal reversion (note 1, Annex C: ISO 2505-1 and ISO 2505-2).

ACCORDING TO THE TEXT OF ISO 12091:1995 — DEFINITIONS, APPARATUS, TEST PIECES, PROCEDURE, CONDITIONS, TEST REPORT (foreword, clauses 1–7, Annexes A–C). The standard was prepared by ISO/TC 138 (Plastics pipes, fittings and valves for the transport of fluids), subcommittee SC 5; first edition 1995-12-01; Annex A is normative, B and C informative. Definitions (clause 2): wall separation — separation between the layers in multilayer designs, normally visible as bubbles in the surface layer (separation of layers at the cut ends is not a failure); blister — internal separation of a pipe wall layer in the form of a bubble. Oven (4.1): air-circulation, thermostatically controlled, maintains the Annex A temperature within ± 2 °C and re-establishes it within 15 min after introduction of the test pieces. Test pieces (clause 5): a piece 300 mm ± 20 mm, which may be cut longitudinally into two equal sections for an outside diameter up to 400 mm or into four above 400 mm; number according to the referring standard, at least three recommended. Procedure (clause 6): conditioning for at least 2 h at 23 °C ± 2 °C; test pieces in the oven not touching each other or the sides (placed horizontally — a bed of talc, fine sand or ballotini recommended); time measured from the return of the temperature; removal without deformation, cooling in air, examination and measurement of the largest dimension of each type of defect. Conditions (Annex A, Table A.1): PVC-U 150 °C ± 2 °C, PE 110 °C ± 2 °C, PP homopolymers and block copolymers 150 °C ± 2 °C, PP random copolymers 135 °C ± 2 °C; time 30 min for wall thickness e ≤ 10 mm and 60 min for e > 10 mm. Recommended requirements (Annex B, informative): depth of cracks or thickness of blisters not more than 30 % of the original wall thickness, and total length of wall separation not more than 20 % of the circumference; the referring standard may adopt more stringent requirements.

STATUS (PKN card as of 12.11.2026). The card for PN-ISO 12091:2009 (Polish version) has no withdrawal label: title "Rury z tworzyw termoplastycznych o ściankach strukturalnych -- Badanie w suszarce", published 20-05-2009, 9 pages, KT 140 for Plastics Pipes, Fittings and Valves, "Implements: ISO 12091:1995 [IDT]", ICS 23.040.20. ISO 12091:1995 in the iTeh catalogue — published. Note the coinciding numbers: PN-EN 12091 is a different standard (thermal insulating products).

HOW MANY LABORATORIES AND IN WHAT FORM (accreditation scope database of the service, read 12.11.2026). The notation "PN-ISO 12091:2009" appears in 3 records at 3 Polish laboratories: AB 005 and AB 237 — together with PN-EN ISO 580:2006 in one item, AB 1256 — on its own. Outside Poland — 2 Czech laboratories: 1234 (ISO 12091) and 1004 (ISO 12091 alongside DIN 53497, ČSN ISO 17484-1, DVGW W 534 and ČSN EN ISO 2578).

WHAT THE LABORATORIES TEST (scope database, complete items — 3 Polish). Structured-wall thermoplastics pipes with a diameter up to 1200 mm — "changes after heating, visual method, method A – heating in air, maximum temperature 200 °C" (AB 1256); thermoplastics pipes with diameters up to 800 mm and injection-moulded fittings up to (400 × 400 × 490) mm (AB 237); pipes, pipe fittings and other plastics products (AB 005). ISO 12091 does not divide the test into methods A and B — the designation "method A" in the AB 1256 item comes from ISO 580.

WHERE AN APPARENTLY CORRECT RESULT IS EASY TO GET. Oven: no air circulation or no recovery of the temperature within 15 min; time measured from insertion instead of from the return of the temperature (6.4). Test pieces: pipes with a smooth external surface (outside the scope), conditioning of 2 h at 23 °C omitted, test pieces touching each other or the sides. Assessment: separation at the cut ends counted as a defect (excluded in 2.1); cracks and blisters related to the circumference or wall separation to the thickness — the standard expresses cracks and blisters as % of the wall (or layer) thickness and wall separation as % of the circumference. Conditions of Table A.1 for a different material (e.g. PP random copolymer at 150 °C instead of 135 °C).

WHAT WE DO NOT GIVE. Part read: the iTeh sample of ISO 12091:1995 (English version — full text: foreword, clauses 1–7, Annexes A–C) and the French version of that sample; Table A.1 was read from the page image. We did not examine differences between ISO 12091:1995 and PN-ISO 12091:2009 (we did not read the Polish text).

Method principle

A piece of structured-wall pipe (300 mm ± 20 mm, if necessary cut longitudinally into 2 or 4 sections), after conditioning for at least 2 h at 23 °C ± 2 °C, is heated in an air-circulation oven at the Annex A temperature (PVC-U and PP homopolymers/block copolymers 150 °C, PE 110 °C, PP random copolymers 135 °C, ± 2 °C) for 30 min (wall up to 10 mm) or 60 min (above 10 mm), counted from the return of the temperature. After cooling in air the surfaces are examined; cracks and blisters are expressed as a percentage of the wall thickness, wall separation as a percentage of the pipe circumference.

Applications

Key parameters

ParameterValue
STATUS (PKN card as of 12.11.2026)PN-ISO 12091:2009 current (Polish version, published 20-05-2009); implements ISO 12091:1995; ISO 12091:1995 — published (iTeh)
Oven — condition (4.1)air circulation, thermostat ± 2 °C, temperature re-established in ≤ 15 min after insertion of the test pieces
Test piece — condition (5.2–5.3)300 mm ± 20 mm; cut into 2 sections (dn ≤ 400 mm) or 4 (> 400 mm) according to the referring standard; ≥ 3 test pieces recommended
Conditioning (6.1)≥ 2 h at 23 °C ± 2 °C
Temperature — Annex A (Table A.1)PVC-U 150 °C ± 2 °C; PE 110 °C ± 2 °C; PP homopolymers and block copolymers 150 °C ± 2 °C; PP random copolymers 135 °C ± 2 °C
Time — Annex A (Table A.1)30 min for e ≤ 10 mm; 60 min for e > 10 mm (e — wall thickness); counted from the return of the temperature
Result (3, 6.7)cracks and blisters — % of the wall (or layer) thickness; wall separation — % of the pipe circumference
Recommended requirements — Annex B (informative)cracks/blisters ≤ 30 % of the original wall thickness; wall separation in total ≤ 20 % of the circumference
Coverage in accreditation scopes (database, read 12.11.2026)3 Polish laboratories, 3 records; 2 Czech

Standard

Standard number
PN-ISO 12091:2009 (Polish version; implements ISO 12091:1995 [IDT])
Title (PL)
Rury z tworzyw termoplastycznych o ściankach strukturalnych — Badanie w suszarce
Title (EN)
Structured-wall thermoplastics pipes — Oven test

Step-by-step procedure

  1. Test pieces

    Pieces of 300 mm ± 20 mm taken according to the referring standard; for dn ≤ 400 mm they may be cut into 2 equal sections, above — into 4; ≥ 3 test pieces recommended (clause 5).

  2. Conditioning and oven

    ≥ 2 h at 23 °C ± 2 °C; oven set to the Table A.1 temperature for the material under test (6.1–6.2).

    🌡 Temperature: 23 °C ± 2 °C; then 110–150 °C ± 2 °C

  3. Heating

    Test pieces not touching each other or the sides (horizontally — on talc, sand or ballotini); 30 min (e ≤ 10 mm) or 60 min (e > 10 mm) from the return of the temperature (6.3–6.4).

    ⏱ Time: 30 or 60 min

  4. Cooling and examination

    Removal without deformation, cooling in air; largest dimension of each type of defect — cracks, blisters, wall separation (6.5–6.7).

  5. Test report

    Temperature and time, maximum cracks/blisters as % of the wall or layer thickness, maximum wall separation as % of the circumference (or of the sum of four sections), other visible defects (clause 7).

Required equipment and apparatus

EquipmentExampleIndicative price
Air-circulation oven (4.1)Thermostatically controlled, ± 2 °C around the Annex A temperature; temperature re-established within 15 min after insertion of the test pieces—
Bed for horizontally placed test pieces (note 4)Talc, fine sand or ballotini — recommended when test pieces are placed horizontally—
Instruments for measuring defectsFor measuring the largest dimension of cracks, blisters and wall separation (6.7); the standard does not specify the type—

Reagents, media and consumables

ReagentCASDetails
Not applicable—Physical test — heating in air; the standard lists no reagents

Health and safety (OHS)

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-ISO 12091:2009 (Polish version; implements ISO 12091:1995 [IDT]) — “Structured-wall thermoplastics pipes — Oven test”.

How does this method work?

A piece of structured-wall pipe (300 mm ± 20 mm, if necessary cut longitudinally into 2 or 4 sections), after conditioning for at least 2 h at 23 °C ± 2 °C, is heated in an air-circulation oven at the Annex A temperature (PVC-U and PP homopolymers/block copolymers 150 °C, PE 110 °C, PP random copolymers 135 °C, ± 2 °C) for 30 min (wall up to 10 mm) or 60 min (above 10 mm), counted from the return of the temperature. After cooling in air the surfaces are examined; cracks and blisters are expressed as a percentage of the wall thickness, wall separation as a percentage of the pipe circumference.

What is the measuring range and accuracy?

STATUS (PKN card as of 12.11.2026): PN-ISO 12091:2009 current (Polish version, published 20-05-2009); implements ISO 12091:1995; ISO 12091:1995 — published (iTeh); Oven — condition (4.1): air circulation, thermostat ± 2 °C, temperature re-established in ≤ 15 min after insertion of the test pieces; Test piece — condition (5.2–5.3): 300 mm ± 20 mm; cut into 2 sections (dn ≤ 400 mm) or 4 (> 400 mm) according to the referring standard; ≥ 3 test pieces recommended; Conditioning (6.1): ≥ 2 h at 23 °C ± 2 °C.

How long does the test take?

The times given for the individual stages add up to approximately 1 h. The procedure comprises 5 steps.

What equipment is required?

Air-circulation oven (4.1), Bed for horizontally placed test pieces (note 4), Instruments for measuring defects.

Where is this test used?

Structured-wall (non-smooth) thermoplastics pipes — pipe wall homogeneity (ISO 12091:1995, clause 1); Not for pipes with a smooth external surface; does not include longitudinal reversion (ISO 2505) (clause 1, note 1); Materials in Table A.1: PVC-U, PE, PP homopolymers and block copolymers, PP random copolymers; In accreditation scopes: 3 Polish laboratories — structured-wall pipes up to 1200 mm, pipes up to 800 mm, fittings and other products.

What safety precautions apply?

The standard contains no safety warning in the text read; the test pieces are removed from the hot oven (up to 150 °C) taking care not to deform or damage them (6.5); TECHNICAL NOTE: separation of layers at the cut ends is not a failure (definition 2.1).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-ISO 12091.

🔍 Find a laboratory performing this test