💡 Floodlights: particular requirements — protection against moisture at least IPX3 for outdoor floodlights, load test of the attachment with sand-bags of 2,4 kN/m² of projected area for 10 min in two positions, glass breaking test of the glass cover and counting of particles in a 50 mm square; PN-EN 60598-2-5

Electronics and EMC PN-EN 60598-2-5

In short

Particular requirements for floodlights for use with electrical light sources on supply voltages not exceeding 1 000 V. The test is performed according to PN-EN 60598-2-5:2016-02 (English version; implements EN 60598-2-5:2015 and IEC 60598-2-5:2015 [IDT]); STATUS (as of 24.11.2026): PKN card: PN-EN 60598-2-5:2016-02 — English version, published 29-02-2016, 22 pages, KT 4 (lighting technology), implements EN 60598-2-5:2015 [IDT] and IEC 60598-2-5:2015 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-5:2000 (Polish version); the card gives no withdrawal date. The procedure comprises 4 steps (about 15 min in total); it is used for: Floodlights for exterior use, interior use or both, for electrical light sources on supply voltages not exceeding 1 000 V (5.1, 5.3.2), Load test of the attachment of floodlights for use above ground level outdoors (5.6.5), Testing of glass covers of floodlights mounted above 5 m — glass breaking test and particle counting (5.6.8, 5.6.8.1).

At a glance

  • Standard: PN-EN 60598-2-5:2016-02 (English version; implements EN 60598-2-5:2015 and IEC 60598-2-5:2015 [IDT])
  • Category: Electronics and EMC
  • Procedure steps: 4
  • Total time of stages: 15 min
  • STATUS (as of 24.11.2026): PKN card: PN-EN 60598-2-5:2016-02 — English version, published 29-02-2016, 22 pages, KT 4 (lighting technology), implements EN 60598-2-5:2015 [IDT] and IEC 60598-2-5:2015 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-5:2000 (Polish version); the card gives no withdrawal date.
  • Scope (5.1): floodlights for electrical light sources, supply voltage not exceeding 1 000 V
  • Protection against moisture (5.6.1): outdoor floodlights — at least IPX3

Overview

WHAT THE STANDARD COVERS. According to 5.1 of IEC 60598-2-5:2015 the standard specifies requirements for floodlights for use with electrical light sources on supply voltages not exceeding 1 000 V. A floodlight is, according to 5.3.2, a luminaire for floodlighting, i.e. lighting of a scene or an object, usually by projectors, in order to increase considerably its illuminance relative to its surroundings (5.3.1); a floodlight can be for exterior or interior use or for both. The standard is read together with IEC 60598-1; the tests from the appropriate sections of Part 1 are carried out in the order listed in Part 2-5 (5.4).

ACCORDING TO THE TEXT OF IEC 60598-2-5:2015 (edition 3.0, 2015-08; the publisher's sample covers the foreword, the introduction and 5.1–5.6.8.1). The standard was prepared by subcommittee IEC SC 34D (luminaires) of IEC TC 34. The third edition replaces the second edition of 1998; according to the foreword it introduces requirements for the glass breaking test. According to the introduction, the mechanical stress on floodlights is similar to that on luminaires for road and street lighting, so the mechanical and breakage test requirements for flat and curved glass were aligned with IEC 60598-2-3. Normative references: IEC 60068-2-75 (hammer tests Eh), IEC 60598-1 and IEC 62262 (IK code).

MARKING AND INSTRUCTIONS (5.5). In addition to Section 3 of IEC 60598-1, the instruction leaflet supplied with the floodlight gives, if applicable: the operating position (if not universal), weight and overall dimensions, maximum projected area, limitation of use indoors and/or outdoors and the maximum mounting height if not exceeding 5 m — relevant to the selected method of protection against falling glass particles and the number of fixing devices.

CONSTRUCTION (5.6). Outdoor floodlights have protection against the ingress of moisture at least equivalent to IPX3 (5.6.1). Lampholder brackets and lamp supports shall accept and retain light sources within the dimensional tolerances of the relevant IEC publication and locate them in relation to the optical control devices (5.6.2); adjustment of the light source position and of the angle shall be positive and locked (5.6.3, 5.6.6); refractors and reflectors shall be fittable only in the correct relationship to the light source (5.6.4). Outdoor floodlights shall be resistant to vibrations occurring in normal use (5.6.7).

ATTACHMENT AND LOAD TEST (5.6.5). The attachment shall be appropriate to the weight of the floodlight; for floodlights for use above ground level outdoors the connection shall withstand a wind speed of 150 km/h on the projected surface of the assembly without undue deflection. Parts of floodlights for mounting heights of 3 m or higher that are fixed other than with at least two devices (e.g. screws) shall have extra protection against falling. Compliance — inspection and, for floodlights for use above ground level outdoors, an additional test: the floodlight is attached in accordance with the manufacturer's recommendations, with its largest projected area (as viewed in elevation) lying in the horizontal plane, and loaded for 10 min with a constant evenly distributed load of sand-bags — 2,4 kN per square metre of projected area; it is then turned 180° in the vertical plane about the point of attachment and the test is repeated. During the test there shall be no failure or movement about the point of attachment, and after either part of the test the permanent set shall not exceed 1°.

GLASS COVERS (5.6.8). Below 5 m there are no additional requirements on glass covers. Above 5 m the cover shall be: a) made of glass that fractures into small pieces, b) made of glass with a high impact shock resistance, or c) protected so that fragments are retained (e.g. guard, film coating). The manufacturer declares the method of protection to the testing laboratory; a) is checked by test and inspection according to 5.6.8.1, b) according to 5.6.8.2, c) by inspection.

GLASS BREAKING TEST (5.6.8.1). No preconditioning. Flat glass is supported over the whole area and shattered with a centre punch at a point 30 mm from the mid-point of one of the longer edges towards the centre. Formed glass is supported on all surfaces (e.g. with sand or a mould) by a layer thicker than 30 mm, its face is completely covered with adhesive film, and it is shattered with a centre punch in the middle of the cover (from the inside or the outside). Within 5 min of fracture the particles are counted in a 50 mm square located approximately at the centre of the area of the coarsest fracture, always within the glass. The glass passes if the square contains more than 40 particles (excluding splinters and pieces less than the full thickness of the glass) and every particle is smaller than 50 mm in all dimensions; for smaller panes the required number is reduced proportionately. At the edges of the square it is recommended to count the particles intersected by two adjacent sides and to ignore those intersected by the other two (Figure 1); where possible the measuring area should not be within 30 mm of any edge, hole or machining of the glass or within a circle of 50 mm around the impact.

WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. The load test is done in two positions (the second after turning through 180°) and the permanent set is assessed after each of them; splinters and pieces thinner than the full glass thickness are not counted, and particles on the edges of the square are counted only on two adjacent sides.

WHAT WE DO NOT GIVE HERE. Clause 5.6.8.2 (glass with high impact shock resistance) and the further clauses 5.7–5.15 (creepage distances and clearances, earthing, terminals, wiring, protection against electric shock, endurance and thermal tests, resistance to dust and moisture, insulation resistance and electric strength, resistance to heat, fire and tracking) and Annex A — the sample ends at 5.6.8.1; we know them only from the titles in the table of contents.

STATUS (as of 24.11.2026). PKN card: PN-EN 60598-2-5:2016-02 “Oprawy oświetleniowe -- Część 2-5: Wymagania szczegółowe -- Projektory iluminacyjne” — English version, published 29-02-2016, 22 pages, KT 4 (lighting technology), implements EN 60598-2-5:2015 [IDT] and IEC 60598-2-5:2015 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-5:2000 (Polish version); the card gives no withdrawal date.

Method principle

The floodlight is tested according to IEC 60598-1 in the order of the Part 1 sections, with the additional requirements of Part 2-5: protection against moisture of at least IPX3 for outdoor floodlights, load on the attachment with sand-bags of 2,4 kN/m² of projected area for 10 min in two positions (permanent set not more than 1°) and — for mounting above 5 m — verification of the declared method of protection against falling glass particles, including a glass breaking test and counting of particles in a 50 mm square.

Applications

Key parameters

ParameterValue
STATUS (as of 24.11.2026)PKN card: PN-EN 60598-2-5:2016-02 — English version, published 29-02-2016, 22 pages, KT 4 (lighting technology), implements EN 60598-2-5:2015 [IDT] and IEC 60598-2-5:2015 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-5:2000 (Polish version); the card gives no withdrawal date.
Scope (5.1)floodlights for electrical light sources, supply voltage not exceeding 1 000 V
Protection against moisture (5.6.1)outdoor floodlights — at least IPX3
Wind (5.6.5)attachment of outdoor floodlights above ground level: 150 km/h on the projected surface without undue deflection
Load test (5.6.5)sand-bags 2,4 kN/m² of projected area, 10 min, then turning through 180° and repeating; permanent set ≤ 1°
Glass covers (5.6.8)mounting above 5 m: glass that fractures into small pieces, glass with high impact shock resistance or retention of fragments; method declared by the manufacturer
Glass breaking test (5.6.8.1)centre punch 30 mm from the mid-point of the longer edge (flat glass) or in the middle of the cover (formed glass, support > 30 mm, film); counting within 5 min in a 50 mm square; more than 40 particles, each < 50 mm
Parts fixed with a single device (5.6.5)for mounting heights of 3 m or more — extra protection against falling

Standard

Standard number
PN-EN 60598-2-5:2016-02 (English version; implements EN 60598-2-5:2015 and IEC 60598-2-5:2015 [IDT])
Title (PL)
Oprawy oświetleniowe — Część 2-5: Wymagania szczegółowe — Projektory iluminacyjne
Title (EN)
Luminaires — Part 2-5: Particular requirements — Floodlights

Step-by-step procedure

  1. Tests according to IEC 60598-1

    Tests from the appropriate sections of Part 1 in the order listed in Part 2-5 (5.4).

  2. Marking and instructions

    Checking the information of 5.5: operating position, weight and dimensions, maximum projected area, limitation of use, maximum mounting height.

  3. Load test of the attachment

    Floodlight attached according to the manufacturer, largest projected area horizontal; sand-bags 2,4 kN/m² for 10 min; turning through 180° in the vertical plane and repeating; assessment: no failure or movement, permanent set ≤ 1° (5.6.5).

    ⏱ Time: 2 × 10 min

  4. Glass covers

    For mounting above 5 m — manufacturer's declaration; for glass that fractures into small pieces: shattering with a centre punch, counting the particles in a 50 mm square within 5 min; requirement: more than 40 particles, each < 50 mm (5.6.8, 5.6.8.1).

    ⏱ Time: within 5 min of fracture

Required equipment and apparatus

EquipmentExampleIndicative price
Sand-bags (5.6.5)Evenly distributed load of 2,4 kN per square metre of projected area of the floodlight—
Centre punch (5.6.8.1, note 1)Steel tool with a sharp point for shattering the glass cover—
Support for formed glass and film (5.6.8.1)E.g. sand or a mould, layer thicker than 30 mm; adhesive film over the whole glass face—
Transparent 50 mm square (5.6.8.1, note 2)Placed over the glass for counting particles, each counted particle marked with a spot of ink—

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-EN 60598-2-5:2016-02 (English version; implements EN 60598-2-5:2015 and IEC 60598-2-5:2015 [IDT]) — “Luminaires — Part 2-5: Particular requirements — Floodlights”.

How does this method work?

The floodlight is tested according to IEC 60598-1 in the order of the Part 1 sections, with the additional requirements of Part 2-5: protection against moisture of at least IPX3 for outdoor floodlights, load on the attachment with sand-bags of 2,4 kN/m² of projected area for 10 min in two positions (permanent set not more than 1°) and — for mounting above 5 m — verification of the declared method of protection against falling glass particles, including a glass breaking test and counting of particles in a 50 mm square.

What is the measuring range and accuracy?

STATUS (as of 24.11.2026): PKN card: PN-EN 60598-2-5:2016-02 — English version, published 29-02-2016, 22 pages, KT 4 (lighting technology), implements EN 60598-2-5:2015 [IDT] and IEC 60598-2-5:2015 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-5:2000 (Polish version); the card gives no withdrawal date.; Scope (5.1): floodlights for electrical light sources, supply voltage not exceeding 1 000 V; Protection against moisture (5.6.1): outdoor floodlights — at least IPX3; Wind (5.6.5): attachment of outdoor floodlights above ground level: 150 km/h on the projected surface without undue deflection.

How long does the test take?

The times given for the individual stages add up to approximately 15 min. The procedure comprises 4 steps.

What equipment is required?

Sand-bags (5.6.5), Centre punch (5.6.8.1, note 1), Support for formed glass and film (5.6.8.1), Transparent 50 mm square (5.6.8.1, note 2).

Where is this test used?

Floodlights for exterior use, interior use or both, for electrical light sources on supply voltages not exceeding 1 000 V (5.1, 5.3.2); Load test of the attachment of floodlights for use above ground level outdoors (5.6.5); Testing of glass covers of floodlights mounted above 5 m — glass breaking test and particle counting (5.6.8, 5.6.8.1); Checking the information in the instructions: operating position, weight, dimensions, projected area, maximum mounting height (5.5).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 60598-2-5.

🔍 Find a laboratory performing this test