🚗 Road vehicles — electrical transients conducted along supply lines in 12 V and 24 V systems: bench tests of emission (slow and fast pulses, artificial network 5 µH / 50 Ω) and immunity (test pulse generator, pulses 3a and 3b); ISO 7637-2

Automotive ISO 7637-2

In short

Test methods and procedures to ensure the compatibility to conducted electrical transients of equipment installed on passenger cars and commercial vehicles fitted with 12 V or 24 V electrical systems, regardless of the propulsion system. The test is performed according to ISO 7637-2:2011 (third edition; PKN has only the older PN-ISO 7637-2:1997); STATUS (as of 18.11.2026): iTeh catalogue: ISO 7637-2:2011 — published 01.03.2011, status “Published”, stage 90.93 (International Standard confirmed), ISO/TC 22/SC 32. PKN: the only card with the number 7637-2 in the search is PN-ISO 7637-2:1997 (Polish version, implements ISO 7637-2:1990 — trucks and buses with 24 V systems), withdrawn 03-09-2018; the PKN search does not return a Polish adoption of the 2011 edition. The procedure comprises 4 steps; it is used for: Electrical and electronic equipment of passenger cars and commercial vehicles with 12 V or 24 V systems, regardless of the propulsion system (clause 1), Measurement of transient emissions on supply lines when switching off inductive loads (power windows, power seats, relays, mirrors) (4.3), Immunity testing of devices against conducted test pulses, including 3a and 3b (4.4).

At a glance

  • Standard: ISO 7637-2:2011 (third edition; PKN has only the older PN-ISO 7637-2:1997)
  • Category: Automotive
  • Procedure steps: 4
  • STATUS (as of 18.11.2026): iTeh catalogue: ISO 7637-2:2011 — published 01.03.2011, status “Published”, stage 90.93 (International Standard confirmed), ISO/TC 22/SC 32. PKN: the only card with the number 7637-2 in the search is PN-ISO 7637-2:1997 (Polish version, implements ISO 7637-2:1990 — trucks and buses with 24 V systems), withdrawn 03-09-2018; the PKN search does not return a Polish adoption of the 2011 edition.
  • Test temperature (4.2): (23 ± 5) °C
  • Supply voltage UA (Table 1): 12 V system: 13,5 V ± 0,5 V; 24 V system: 27 V ± 1 V (measured at the generator output)

Overview

WHAT THE STANDARD COVERS. According to clause 1 of ISO 7637-2:2011 this part of ISO 7637 specifies test methods and procedures to ensure the compatibility to conducted electrical transients of equipment installed on passenger cars and commercial vehicles fitted with 12 V or 24 V electrical systems. It describes bench tests for both the injection and the measurement of transients and is applicable to all types of road vehicles independent of the propulsion system (e.g. spark-ignition or diesel engine, electric motor). The function performance status classification for immunity to transients is given in Annex A.

ACCORDING TO THE TEXT OF ISO 7637-2:2011 (publisher's sample: foreword, clauses 1–4 and 5.1). The standard was prepared by ISO/TC 22 (Road vehicles), subcommittee SC 3 (Electrical and electronic equipment). The third edition replaces the second (ISO 7637-2:2004), has been technically revised and incorporates amendment ISO 7637-2:2004/Amd.1:2008; it no longer specifies test pulses 4, 5a and 5b, which are now specified in ISO 16750-2 and ISO 21848. The ISO 7637 series: Part 1 — definitions and general considerations, Part 2 — electrical transient conduction along supply lines only, Part 3 — electrical transient transmission by capacitive and inductive coupling via lines other than supply lines. Normative reference: ISO 7637-1 (definitions).

GENERAL PROCEDURE (4.1–4.2). The tests are performed in the laboratory as bench tests; the methods with the artificial network give comparable results between laboratories. The pulses of 5.6 are characteristic of typical pulses but may not cover all transients occurring in a vehicle; the test pulses required for a specific device are defined by the vehicle manufacturer. Ambient temperature during the test: (23 ± 5) °C. Supply voltage UA (Table 1), measured at the output of the pulse generator: 13,5 V ± 0,5 V for 12 V systems and 27 V ± 1 V for 24 V systems, unless other values are agreed by the users of the standard (then they are documented in the test report).

TRANSIENT EMISSIONS (4.3). The test applies to a device under test (DUT) with or without an internal mechanical or electronic switch driving an inductive load (e.g. power window, power seat, relay, electric mirror). Transients are measured through the artificial network, which standardizes the impedance loading on the DUT; all wiring connections between the artificial network, the switch and the DUT are routed (50 ± 5) mm above the metal ground plane, and without test plan requirements the DUT is placed on non-conductive material (50 ± 5) mm above the plane. The supply voltage and the disturbance voltage are measured with a voltage probe and an oscilloscope or waveform acquisition equipment; the sampling rate and trigger level are chosen to capture the complete transient. Unless otherwise specified, ten waveform acquisitions are necessary, and the report gives the waveforms with the highest positive and negative amplitude (evaluation according to Annex B). Set-up for slow pulses (ms range or slower, Figure 1 a): the disturbance source via the artificial network, the shunt resistor Rs, the switch S (representing e.g. the ignition switch or a relay) and the power supply — transients are measured at the moment of opening switch S. Set-ups for fast pulses (ns to µs range): Figure 1 b) for a DUT without an internal switch and Figure 1 c) for a DUT with an internal switch (then the internal switch is operated and the probe is connected as close to the DUT terminals as possible).

TRANSIENT IMMUNITY (4.4). The DUT is placed on a non-conductive support of low relative permittivity (εr ≤ 1,4) with a thickness of (50 ± 5) mm; for test pulses 3a and 3b the leads between the generator and the DUT are laid out in a straight parallel line on such a support with a length of (500 ± 100) mm. The load simulator is preferably placed directly on the ground plane (a metallic case bonded to the plane). First, without the DUT, the test pulse generator is set up (polarity, amplitude, duration, resistance; Figure 2 a) — the peak voltage Us at the required test level with a tolerance of +10 % / 0 %; then the DUT is connected with the oscilloscope disconnected (Figure 2 b), and its function is evaluated during and/or after the application of the pulses. DC power ground connection for test pulse 3 — at most 100 mm.

ARTIFICIAL NETWORK (5.1). It replaces in the laboratory the impedance of the vehicle wiring harness; the impedance |ZPB| between terminals P and B (with A and B short-circuited) as a function of frequency shall not deviate by more than 10 % from the curve of Figure 4. Components: inductor L = 5 µH (air-core), internal resistance between P and A < 5 mΩ, capacitor C = 0,1 µF (200 V AC and 1500 V DC), resistor R = 50 Ω. Further clauses according to the table of contents — shunt resistor Rs, switch S, power supply, measurement instrumentation and test pulse generator (5.2–5.6) — the sample does not contain their text, so we do not give the pulse parameters and test levels.

STATUS (as of 18.11.2026). iTeh catalogue: ISO 7637-2:2011 — published 01.03.2011, status “Published”, stage 90.93 (International Standard confirmed), ISO/TC 22/SC 32. PKN: the only card with the number 7637-2 in the search is PN-ISO 7637-2:1997 (Polish version, implements ISO 7637-2:1990 — trucks and buses with 24 V systems), withdrawn 03-09-2018; the PKN search does not return a Polish adoption of the 2011 edition.

Method principle

Laboratory bench test: emission is measured by switching the supply of the device (switch S or the internal switch) and recording with an oscilloscope the transients at the terminals of the artificial network, which replaces the impedance of the vehicle wiring harness; immunity is checked by applying to the supply lines pulses from a test pulse generator set beforehand without the device to the required amplitude, and by evaluating the function performance status of the device.

Applications

Key parameters

ParameterValue
STATUS (as of 18.11.2026)iTeh catalogue: ISO 7637-2:2011 — published 01.03.2011, status “Published”, stage 90.93 (International Standard confirmed), ISO/TC 22/SC 32. PKN: the only card with the number 7637-2 in the search is PN-ISO 7637-2:1997 (Polish version, implements ISO 7637-2:1990 — trucks and buses with 24 V systems), withdrawn 03-09-2018; the PKN search does not return a Polish adoption of the 2011 edition.
Test temperature (4.2)(23 ± 5) °C
Supply voltage UA (Table 1)12 V system: 13,5 V ± 0,5 V; 24 V system: 27 V ± 1 V (measured at the generator output)
Emission set-up (4.3.1)connections and DUT (50 ± 5) mm above the ground plane; 10 acquisitions, report the waveforms with the highest positive and negative amplitude
Immunity set-up (4.4)support εr ≤ 1,4, thickness (50 ± 5) mm; leads for pulses 3a, 3b (500 ± 100) mm; supply ground for pulse 3 ≤ 100 mm
Generator adjustment (4.4.4)without DUT; peak voltage Us with a tolerance of +10 % / 0 %
Artificial network (5.1)L = 5 µH (air-core); RPA < 5 mΩ; C = 0,1 µF (200 V AC, 1500 V DC); R = 50 Ω; deviation of |ZPB| ≤ 10 % from the curve of Figure 4
Pulses moved elsewhere (foreword)pulses 4, 5a and 5b — in ISO 16750-2 and ISO 21848

Standard

Standard number
ISO 7637-2:2011 (third edition; PKN has only the older PN-ISO 7637-2:1997)
Title (PL)
Pojazdy drogowe — Zaburzenia elektryczne od przewodzenia i sprzężeń — Część 2: Elektryczne stany przejściowe przewodzone wyłącznie wzdłuż linii zasilania
Title (EN)
Road vehicles — Electrical disturbances from conduction and coupling — Part 2: Electrical transient conduction along supply lines only

Step-by-step procedure

  1. Test plan and conditions

    Selection of the pulses required by the vehicle manufacturer, DUT operating conditions, grounding of the case; temperature (23 ± 5) °C, supply voltage UA according to Table 1.

  2. Emission measurement

    Set-up with the artificial network (Figure 1 a, b or c), connections (50 ± 5) mm above the ground plane; operating switch S or the internal switch, oscilloscope recording — at least 10 waveforms, evaluation according to Annex B.

  3. Generator adjustment

    Without the DUT (Figure 2 a): pulse polarity, amplitude, duration and resistance; Us at the test level with a tolerance of +10 % / 0 %.

  4. Immunity test

    Connecting the DUT with the oscilloscope disconnected (Figure 2 b), applying the pulses, evaluating the DUT function during and/or after the test according to the classification of Annex A.

Required equipment and apparatus

EquipmentExampleIndicative price
Artificial network (5.1)Inductor 5 µH, capacitor 0,1 µF, resistor 50 Ω; terminals A (supply), B (common), P (DUT)—
Test pulse generator (5.6)Set up without the DUT for pulse polarity, amplitude, duration and resistance—
Oscilloscope and voltage probe (5.5)Recording of the complete transient waveform with its positive and negative amplitude—
Ground plane, shunt resistor Rs, switch S, power supply (5.2–5.4)Elements of the emission (Figure 1) and immunity (Figure 2) set-ups—

Frequently asked questions

Which standard describes this test?

The test is performed according to ISO 7637-2:2011 (third edition; PKN has only the older PN-ISO 7637-2:1997) — “Road vehicles — Electrical disturbances from conduction and coupling — Part 2: Electrical transient conduction along supply lines only”.

How does this method work?

Laboratory bench test: emission is measured by switching the supply of the device (switch S or the internal switch) and recording with an oscilloscope the transients at the terminals of the artificial network, which replaces the impedance of the vehicle wiring harness; immunity is checked by applying to the supply lines pulses from a test pulse generator set beforehand without the device to the required amplitude, and by evaluating the function performance status of the device.

What is the measuring range and accuracy?

STATUS (as of 18.11.2026): iTeh catalogue: ISO 7637-2:2011 — published 01.03.2011, status “Published”, stage 90.93 (International Standard confirmed), ISO/TC 22/SC 32. PKN: the only card with the number 7637-2 in the search is PN-ISO 7637-2:1997 (Polish version, implements ISO 7637-2:1990 — trucks and buses with 24 V systems), withdrawn 03-09-2018; the PKN search does not return a Polish adoption of the 2011 edition.; Test temperature (4.2): (23 ± 5) °C; Supply voltage UA (Table 1): 12 V system: 13,5 V ± 0,5 V; 24 V system: 27 V ± 1 V (measured at the generator output); Emission set-up (4.3.1): connections and DUT (50 ± 5) mm above the ground plane; 10 acquisitions, report the waveforms with the highest positive and negative amplitude.

How long does the test take?

The procedure comprises 4 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.

What equipment is required?

Artificial network (5.1), Test pulse generator (5.6), Oscilloscope and voltage probe (5.5), Ground plane, shunt resistor Rs, switch S, power supply (5.2–5.4).

Where is this test used?

Electrical and electronic equipment of passenger cars and commercial vehicles with 12 V or 24 V systems, regardless of the propulsion system (clause 1); Measurement of transient emissions on supply lines when switching off inductive loads (power windows, power seats, relays, mirrors) (4.3); Immunity testing of devices against conducted test pulses, including 3a and 3b (4.4); Classification of the function performance status of a device for immunity to transients (Annex A).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number ISO 7637-2.