🔥 Hard coal, brown coal and lignite, coke — total sulfur by the Eschka method: ignition of the test portion with Eschka mixture at 800 °C, extraction of sulfate with hydrochloric acid, precipitation with barium chloride and weighing of barium sulfate, blank with potassium sulfate, result % (m/m) on the air-dried basis; PN-ISO 334

Petrochemistry PN-ISO 334

In short

Determination of total sulfur in hard coal, brown coal and lignite and in coke by the Eschka method — the reference method according to ISO 334:1992. The test is performed according to PN-ISO 334:1997 (Polish version; implements ISO 334:1992 [IDT]); STATUS (PKN card as of 12.11.2026): PN-ISO 334:1997 current (Polish version, published 28-10-1997); implements ISO 334:1992, replaced PN-G-04514-01:1981; ISO 334:1992 in iTeh — withdrawn. The procedure comprises 5 steps; it is used for: Hard coal, brown coal and lignite, coke — total sulfur; reference method (ISO 334:1992, clause 1), Second reference method: ISO 351:1984 (high-temperature combustion); instrumental methods after showing freedom from bias and precision at least as in clause 9 (introduction), In accreditation scopes: 5 Polish laboratories — hard coal (all), brown coal, coke, semi-coke and processed solid fuels.

At a glance

  • Standard: PN-ISO 334:1997 (Polish version; implements ISO 334:1992 [IDT])
  • Category: Petrochemistry
  • Procedure steps: 5
  • STATUS (PKN card as of 12.11.2026): PN-ISO 334:1997 current (Polish version, published 28-10-1997); implements ISO 334:1992, replaced PN-G-04514-01:1981; ISO 334:1992 in iTeh — withdrawn
  • Eschka mixture — composition (4.1): 2 parts by mass of light calcined MgO + 1 part anhydrous Na2CO3 (or K2CO3); all through a 212 µm sieve
  • Test portion — condition (7.1, Table 1): coal: 1.0 g (sulfur < 5 %), 0.5 g (5–10 %), 0.25 g (> 10 %); coke: 1 g; weighed to 0.1 mg

Overview

WHAT THE STANDARD COVERS. According to clause 1 of ISO 334:1992 the standard specifies a reference method for determining the total sulfur content of hard coal, brown coals and lignites, and coke by the Eschka method. The introduction names an alternative reference method — ISO 351:1984 (high-temperature combustion) — and allows faster instrumental methods if they are shown to be free from bias compared with this method and give repeatability and reproducibility the same as or better than those in clause 9.

ACCORDING TO THE TEXT OF ISO 334:1992 — REAGENTS, APPARATUS, PROCEDURE, CALCULATION, PRECISION (foreword, introduction, clauses 1–10, Annex A). The standard was prepared by ISO/TC 27 (Solid mineral fuels), subcommittee SC 5 (Methods of analysis); the second edition of 1992-12-15 replaced ISO 334:1975. Principle (clause 3): the test portion is ignited with Eschka mixture in an oxidizing atmosphere, the sulfate is extracted with hydrochloric acid solution and precipitated with barium chloride. Eschka mixture (4.1): 2 parts by mass of light calcined magnesium oxide and 1 part of anhydrous sodium (or potassium) carbonate, entirely passing a 212 µm sieve. Test portion (7.1, Table 1): coal — 1.0 g for expected sulfur below 5 %, 0.5 g for 5–10 %, 0.25 g above 10 %; coke — 1 g; weighed to 0.1 mg. Charging the crucible (7.2): 0.5 g of mixture on the bottom, the test portion mixed with 2.5 g of mixture, 1.0 g on top. Ignition (7.3): coal — crucible into the cold furnace, heating to 800 °C ± 25 °C in about 1 h and at least 1.5 h at that temperature; coke — crucible on the cold plate into the furnace at 800 °C ± 25 °C, at least 1.5 h. Unburnt particles after ignition — the determination is stopped and repeated (7.4). Extraction (7.5): hydrochloric acid to dissolve (normally 17 ml), boiling for 5 min, filtration, washing with five 20 ml portions of hot water, neutralization with ammonia to methyl red and 1 ml excess of acid. Precipitation (7.6): dilution to about 200 ml, 10 ml of cold barium chloride solution delivered in about 20 s into the hot solution, 30 min just below boiling; filtration through ashless paper, a paper-pulp pad or in a Gooch crucible; washing until no opalescence with silver nitrate (not more than 250 ml); ignition at 800 °C for 15 min or drying of the Gooch crucible for 1 h at 130 °C ± 10 °C. Blank test (7.7) — without the test portion, with 25.0 ml of potassium sulfate solution added.

STATUS (PKN card as of 12.11.2026). The card for PN-ISO 334:1997 (Polish version) has no withdrawal label: published 28-10-1997, 8 pages, KT 220 for Natural Solid Fuels, "Implements: ISO 334:1992 [IDT]", "Replaces: PN-G-04514-01:1981 - Polish version", ICS 73.040, 75.160.10. In the iTeh catalogue ISO 334:1992 has the status "withdrawn" (replaced by later editions of ISO 334), while in PKN the Polish edition of 1997 implementing ISO 334:1992 is current — this is the version cited by all laboratories in the database.

HOW MANY LABORATORIES AND IN WHAT FORM (accreditation scope database of the service, read 12.11.2026). The notation "PN-ISO 334:1997" appears in 5 records at 5 Polish laboratories: AB 005, AB 103, AB 300, AB 1060 and AB 1716 — all "total sulfur content"; the technique is described as "gravimetric method" (AB 005, AB 300, AB 1060) or "Eschka method" (AB 103, AB 1716). Outside Poland the notation ISO 334 is not in the database.

WHAT THE LABORATORIES TEST (scope database, complete items — 5 Polish). Hard coal — all 5; AB 005 also brown coal and coke from hard coal, AB 103 brown coal, coke and semi-coke from hard coal and processed solid fuels. Measuring ranges: (0.05–5.00) % (AB 300), (0.100–2.500) % (AB 1060), (0.20–7.00) % (AB 005), (0.4–6.0) % (AB 1716), (0.50–6.00) % (AB 103). Semi-coke and processed solid fuels (AB 103) go beyond the scope of the standard, which names hard coal, brown coal and lignite and coke.

WHERE AN APPARENTLY CORRECT RESULT IS EASY TO GET. Ignition: too rapid heating of coal or less than 1.5 h at 800 °C leaves unburnt particles — according to 7.4 the determination must then be repeated, not continued; insufficient furnace ventilation (standard: about five air changes per minute). Test portion: too large for a high sulfur content (Table 1). Precipitation: barium chloride added quickly or to a cold solution, less than 30 min just below boiling; precipitate not washed enough (silver nitrate check). Result: blank with potassium sulfate omitted, or a basis other than air-dried without determining moisture (clauses 6 and 8).

WHAT WE DO NOT GIVE. Part read: the iTeh sample of ISO 334:1992 (English version: foreword, introduction, clauses 1–10 and the beginning of Annex A); Table 1 and the formula of clause 8 were read from the page images. We do not give the rest of Annex A (derivation of the factors) apart from Table A.1 of atomic masses. We did not examine differences between ISO 334:1992 and later editions of ISO 334 — the laboratories in the database cite only PN-ISO 334:1997.

Method principle

The test portion (0.25–1 g) is ignited in a crucible in intimate contact with 4 g of Eschka mixture (2 parts MgO, 1 part anhydrous Na2CO3 or K2CO3) in an oxidizing atmosphere at 800 °C ± 25 °C for at least 1.5 h; the combustible matter burns off and the sulfur is converted to sulfate. The sulfate is extracted with hydrochloric acid solution, precipitated with barium chloride and weighed as barium sulfate. Total sulfur is calculated from wS = 13.74 (m2 − m3 + 0.033 48 ρK2SO4)/m1 (m1 — test portion, g; m2 and m3 — barium sulfate in the determination and blank, g; ρK2SO4 — concentration of the potassium sulfate solution, g/l), on the air-dried basis, to 0.1 %.

Applications

Key parameters

ParameterValue
STATUS (PKN card as of 12.11.2026)PN-ISO 334:1997 current (Polish version, published 28-10-1997); implements ISO 334:1992, replaced PN-G-04514-01:1981; ISO 334:1992 in iTeh — withdrawn
Eschka mixture — composition (4.1)2 parts by mass of light calcined MgO + 1 part anhydrous Na2CO3 (or K2CO3); all through a 212 µm sieve
Test portion — condition (7.1, Table 1)coal: 1.0 g (sulfur < 5 %), 0.5 g (5–10 %), 0.25 g (> 10 %); coke: 1 g; weighed to 0.1 mg
Crucible — charging (7.2)0.5 g of mixture on the bottom + test portion with 2.5 g of mixture + 1.0 g on top (4 g in total)
Ignition — condition (5.3, 7.3)800 °C ± 25 °C; coal — from a cold furnace, heating in about 1 h, then ≥ 1.5 h; coke — into the furnace at 800 °C, ≥ 1.5 h; about 5 air changes/min
Precipitation — condition (7.6)about 200 ml, 10 ml of cold BaCl2 (about 85 g/l) in about 20 s into the hot solution; 30 min just below boiling
Result — calculation (clause 8)wS = 13.74 (m2 − m3 + 0.033 48 ρK2SO4)/m1; mean of two determinations, to 0.1 % (m/m), air-dried basis
Precision (clause 9)repeatability limit 0.05 % absolute; reproducibility critical difference 0.1 % absolute (95 % confidence level)
Coverage in accreditation scopes (database, read 12.11.2026)5 Polish laboratories, 5 records; ranges from (0.05–5.00) % to (0.20–7.00) %

Standard

Standard number
PN-ISO 334:1997 (Polish version; implements ISO 334:1992 [IDT])
Title (PL)
Paliwa stałe — Oznaczanie zawartości siarki całkowitej — Metoda Eschki
Title (EN)
Solid mineral fuels — Determination of total sulfur — Eschka method

Step-by-step procedure

  1. Sample and test portion

    General analysis test sample according to ISO 1988, ISO 2309 or ISO 5069-2, equilibrated with laboratory humidity and mixed ≥ 1 min; test portion according to Table 1 (coal) or 1 g (coke), to 0.1 mg; moisture — if the result is to be on a basis other than air-dried (clause 6, 7.1).

  2. Charging the crucible and ignition

    0.5 g of mixture on the bottom, test portion with 2.5 g, 1.0 g on top; coal — from a cold furnace to 800 °C in about 1 h and ≥ 1.5 h; coke — on the cold plate into the furnace at 800 °C, ≥ 1.5 h (7.2–7.3).

    🌡 Temperature: 800 °C ± 25 °C

  3. Transfer and extraction

    Into a 400 ml beaker with 25–30 ml of water (unburnt particles — repeat the determination); hydrochloric acid to dissolve (normally 17 ml), boiling 5 min, filtration, 5 × 20 ml of hot water; ammonia to methyl red, redissolution of the precipitate and 1 ml excess of HCl (7.4–7.5).

  4. Precipitation and weighing

    About 200 ml, boiling, 10 ml of cold BaCl2 in about 20 s, 30 min just below boiling; filtration by technique a), b) or c), washing until no opalescence with AgNO3 (≤ 250 ml); ignition 15 min at 800 °C or drying of the Gooch crucible 1 h at 130 °C; weighing to 0.1 mg (7.6).

  5. Blank and result

    Blank without the test portion with 25.0 ml of K2SO4 solution (7.7); wS according to the formula of clause 8, mean of two determinations to 0.1 % (m/m); repeatability 0.05 %, reproducibility 0.1 %; test report according to clause 10.

Required equipment and apparatus

EquipmentExampleIndicative price
Analytical balance and graduated glassware (5.1–5.2)Weighing to 0.1 mg; class A glassware—
Muffle furnace (5.3)Electrically heated, 800 °C ± 25 °C, ventilation of about five air changes per minute—
Crucible and plate (5.4–5.5)Platinum, silica or glazed porcelain crucible, about 25 ml; silica (or other refractory) plate 6 mm thick—
Gooch crucible and oven (5.6–5.7)Glazed porcelain or sintered glass crucible; air oven 130 °C ± 10 °C—

Reagents, media and consumables

ReagentCASDetails
Eschka mixture—2 parts by mass of light calcined magnesium oxide and 1 part of anhydrous sodium (or potassium) carbonate; all through a 212 µm sieve (4.1)
Concentrated hydrochloric acid—ρ about 1.18 g/ml, about 36 % (m/m) (4.2)
Potassium sulfate solution—About 2 g (weighed to 0.1 mg) dried at 105–110 °C, dissolved and made up to 1 l — for the blank test (4.3, 7.7)
Barium chloride solution—About 85 g/l: 100 g of barium chloride dihydrate to 1 l, filtered before use (4.4)
Methyl red, ammonia, silver nitrate—Indicator 1 g/l (sodium salt); concentrated ammonia ≥ 25 % (m/m); silver nitrate 17 g/l in a dark bottle (4.5–4.7)

Health and safety (OHS)

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-ISO 334:1997 (Polish version; implements ISO 334:1992 [IDT]) — “Solid mineral fuels — Determination of total sulfur — Eschka method”.

How does this method work?

The test portion (0.25–1 g) is ignited in a crucible in intimate contact with 4 g of Eschka mixture (2 parts MgO, 1 part anhydrous Na2CO3 or K2CO3) in an oxidizing atmosphere at 800 °C ± 25 °C for at least 1.

What is the measuring range and accuracy?

STATUS (PKN card as of 12.11.2026): PN-ISO 334:1997 current (Polish version, published 28-10-1997); implements ISO 334:1992, replaced PN-G-04514-01:1981; ISO 334:1992 in iTeh — withdrawn; Eschka mixture — composition (4.1): 2 parts by mass of light calcined MgO + 1 part anhydrous Na2CO3 (or K2CO3); all through a 212 µm sieve; Test portion — condition (7.1, Table 1): coal: 1.0 g (sulfur < 5 %), 0.5 g (5–10 %), 0.25 g (> 10 %); coke: 1 g; weighed to 0.1 mg; Crucible — charging (7.2): 0.5 g of mixture on the bottom + test portion with 2.5 g of mixture + 1.0 g on top (4 g in total).

How long does the test take?

The procedure comprises 5 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.

What equipment is required?

Analytical balance and graduated glassware (5.1–5.2), Muffle furnace (5.3), Crucible and plate (5.4–5.5), Gooch crucible and oven (5.6–5.7).

Where is this test used?

Hard coal, brown coal and lignite, coke — total sulfur; reference method (ISO 334:1992, clause 1); Second reference method: ISO 351:1984 (high-temperature combustion); instrumental methods after showing freedom from bias and precision at least as in clause 9 (introduction); In accreditation scopes: 5 Polish laboratories — hard coal (all), brown coal, coke, semi-coke and processed solid fuels.

What safety precautions apply?

The standard warns: care should be exercised when handling the reagents, many of which are toxic and corrosive (clause 4); Cracking of porcelain crucibles can be prevented by cooling them slowly in supports of light porous firebrick after removal from the furnace (note 2 to 7.3.1); TECHNICAL NOTE: unburnt particles after ignition invalidate the determination — it must be repeated (7.4).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-ISO 334.

🔍 Find a laboratory performing this test