💡 Ground recessed luminaires (up to 1000 V, indoor and outdoor): marking of the rated load and of the maximum surface temperature T, static load test with a Ø 50 mm punch, torque and shear tests in areas with vehicle traffic; PN-EN 60598-2-13
In short
Particular requirements for ground recessed luminaires with electric light sources, supplied at voltages up to 1000 V, for indoor and outdoor use — in gardens, yards, carriageways, parking lots, cycleways, footways and pedestrian areas, in swimming pool areas outside SELV zones and in nurseries. The test is performed according to PN-EN 60598-2-13:2007 (Polish version; implements EN 60598-2-13:2006 and IEC 60598-2-13:2006 [IDT]) with amendments A1:2012 (Polish version), A2:2017-02 and A11:2021-09 (English versions); STATUS (as of 18.11.2026): PKN cards: PN-EN 60598-2-13:2007 “Oprawy oświetleniowe -- Część 2-13: Wymagania szczegółowe -- Oprawy oświetleniowe wbudowywane w podłoże” — Polish version, published 30-08-2007, 13 pages, KT 4 Lighting Technology, implements EN 60598-2-13:2006 with the corrigendum of December 2006 and IEC 60598-2-13:2006 [IDT], replaces PN-EN 60598-2-13:2006 and its corrigendum AC:2007; amendments: A1:2012 (Polish version, published 18-11-2013 — changed test procedure in 13.6.1 and Figure 2; implements EN 60598-2-13:2006/A1:2012 and IEC 60598-2-13:2006/AMD1:2011), A2:2017-02 (English version, published 07-02-2017 — a new paragraph on photobiological safety before Table A.1; implements EN 60598-2-13:2006/A2:2016 and IEC 60598-2-13:2006/AMD2:2016) and A11:2021-09 (English version, published 13-09-2021 — new Annexes ZA and ZZ; implements EN 60598-2-13:2006/A11:2021); the cards give no withdrawal date. iTeh catalogue: EN 60598-2-13:2006 — published 07.08.2006, status “Published”, stage 90.93 (decision to confirm). The procedure comprises 4 steps; it is used for: Ground recessed luminaires up to 1000 V in gardens, yards, carriageways, parking lots, cycleways, footways, pedestrian areas, swimming pool areas outside SELV zones and nurseries (13.1), Test of resistance of the luminaire cover to static load (13.6.1), Torque and shear tests of luminaires in areas with vehicle traffic (13.6.2).
At a glance
- Standard: PN-EN 60598-2-13:2007 (Polish version; implements EN 60598-2-13:2006 and IEC 60598-2-13:2006 [IDT]) with amendments A1:2012 (Polish version), A2:2017-02 and A11:2021-09 (English versions)
- Category: Electronics and EMC
- Procedure steps: 4
- STATUS (as of 18.11.2026): PKN cards: PN-EN 60598-2-13:2007 “Oprawy oświetleniowe -- Część 2-13: Wymagania szczegółowe -- Oprawy oświetleniowe wbudowywane w podłoże” — Polish version, published 30-08-2007, 13 pages, KT 4 Lighting Technology, implements EN 60598-2-13:2006 with the corrigendum of December 2006 and IEC 60598-2-13:2006 [IDT], replaces PN-EN 60598-2-13:2006 and its corrigendum AC:2007; amendments: A1:2012 (Polish version, published 18-11-2013 — changed test procedure in 13.6.1 and Figure 2; implements EN 60598-2-13:2006/A1:2012 and IEC 60598-2-13:2006/AMD1:2011), A2:2017-02 (English version, published 07-02-2017 — a new paragraph on photobiological safety before Table A.1; implements EN 60598-2-13:2006/A2:2016 and IEC 60598-2-13:2006/AMD2:2016) and A11:2021-09 (English version, published 13-09-2021 — new Annexes ZA and ZZ; implements EN 60598-2-13:2006/A11:2021); the cards give no withdrawal date. iTeh catalogue: EN 60598-2-13:2006 — published 07.08.2006, status “Published”, stage 90.93 (decision to confirm).
- Scope (13.1): ground recessed luminaires, supply up to 1000 V, indoor and outdoor; excluding luminaires for motorised roads and airfields (IEC 61827)
- Marking (13.5): rated load in N; maximum surface temperature T in °C (Table 3.1 of IEC 60598-1, column B); connecting box
Overview
WHAT THE STANDARD COVERS. According to 13.1 of IEC 60598-2-13 this Part 2 of IEC 60598 specifies requirements for ground recessed luminaires incorporating electric light sources for operation from supply voltages up to 1000 V, for indoor or outdoor use, e.g. in gardens, yards, carriageways, parking lots, cycleways, footways, pedestrian areas, swimming pool areas outside zones for SELV, nurseries and similar applications. It does not cover ground recessed luminaires for motorised roads and for airfields, already specified in IEC 61827. A ground recessed luminaire (13.3.1) is a luminaire suitable to be installed in the ground, having the supply connections and electrical components located below ground level; the rated maximum surface temperature T (13.3.2) is the highest temperature on the accessible outer surface under normal operating conditions according to 13.12.
ACCORDING TO THE TEXT OF IEC 60598-2-13:2006 + A1:2011 (publisher's sample, consolidated edition 1.1 of 2012-02: foreword and 13.1 to 13.6.2.1). The standard was prepared by IEC subcommittee SC 34D (Luminaires) of TC 34; it is read together with IEC 60598-1 (general requirements and tests) and was established on the basis of the sixth edition of that standard. Edition 1.1 is the first edition (2006) with amendment 1 (2011). Normative references, general test requirements and classification — according to Sections 0 and 2 of IEC 60598-1.
MARKING (13.5). In addition to Section 3 of IEC 60598-1: the rated load in N according to 13.6.1 (in the manufacturer's instructions); the rated maximum surface temperature T in °C — the T marking on the luminaire according to the second column (B) of Table 3.1 of IEC 60598-1 and/or in the manufacturer's instructions and catalogues; in the instructions — where necessary, information about the external connecting box. Compliance is checked by inspection.
RESISTANCE TO STATIC LOAD (13.6.1). The luminaire shall withstand the minimum static load given in the manufacturer's instructions. The sample is mounted as in normal use, in accordance with the manufacturer's instructions. The test load (maintained with a tolerance of ± 3 %) is applied to the top side of the luminaire — according to amendment 1 — by a cylindrical steel punch equipped with a sheet of rubber in contact with the luminaire: a punch of 50 mm diameter (or the luminaire diameter D if smaller than 50 mm) and 50 mm thickness; rubber with a hardness of Shore A 65 ± 5 (measured with a type A durometer) and a thickness of 10 mm. The vertical axis of the punch shall be perpendicular and coincide with the geometrical centre of the translucent cover (Figure 2). The load is applied uniformly at a rate not greater than 5000 N/min, and the maximum load is maintained for 1 min. After the test the sample shall comply with the conformity requirements of 4.13.1 of IEC 60598-1 (as after the mechanical impact test). More samples may be necessary to perform all tests, and some of them may be destroyed (note to 13.6).
TORQUE AND SHEAR (13.6.2). Luminaires for areas where motor vehicles may circulate (carriageways, parking areas — items 3 and 4 of Table A.1) shall withstand the forces exerted by a turning, braking or accelerating tyre; compliance is checked by the tests of 13.6.2.1 and 13.6.2.2. Torque test (13.6.2.1): the joints between parts of the luminaire that may be subjected to rotational force are subjected to a 50 N torque force for one minute (Figure 3 — a 50 N force for 60 s on a 1 m bar, example), each joint separately; after the test — the requirements of 4.13.1 of IEC 60598-1. The test checks both the fixing of the components and the fixing of the luminaire to the ground. The sample does not contain the text of the shear test (13.6.2.2), of the further construction requirements and of Annex A (basic dimensions of Figure 1, Table A.1), so we do not give them.
STATUS (as of 18.11.2026). PKN cards: PN-EN 60598-2-13:2007 “Oprawy oświetleniowe -- Część 2-13: Wymagania szczegółowe -- Oprawy oświetleniowe wbudowywane w podłoże” — Polish version, published 30-08-2007, 13 pages, KT 4 Lighting Technology, implements EN 60598-2-13:2006 with the corrigendum of December 2006 and IEC 60598-2-13:2006 [IDT], replaces PN-EN 60598-2-13:2006 and its corrigendum AC:2007; amendments: A1:2012 (Polish version, published 18-11-2013 — changed test procedure in 13.6.1 and Figure 2; implements EN 60598-2-13:2006/A1:2012 and IEC 60598-2-13:2006/AMD1:2011), A2:2017-02 (English version, published 07-02-2017 — a new paragraph on photobiological safety before Table A.1; implements EN 60598-2-13:2006/A2:2016 and IEC 60598-2-13:2006/AMD2:2016) and A11:2021-09 (English version, published 13-09-2021 — new Annexes ZA and ZZ; implements EN 60598-2-13:2006/A11:2021); the cards give no withdrawal date. iTeh catalogue: EN 60598-2-13:2006 — published 07.08.2006, status “Published”, stage 90.93 (decision to confirm).
Method principle
The luminaire, mounted as in the ground, is loaded from the top through a Ø 50 mm steel punch with Shore A 65 ± 5 rubber of 10 mm thickness, increasing to the rated load from the instructions (≤ 5000 N/min, held for 1 min), and luminaires for areas with vehicle traffic are additionally subjected to a 50 N torque force for 1 min at each joint and to a shear test. After the tests the luminaire shall comply with 4.13.1 of IEC 60598-1; the marking gives the rated load in N and the maximum surface temperature T.
Applications
- Ground recessed luminaires up to 1000 V in gardens, yards, carriageways, parking lots, cycleways, footways, pedestrian areas, swimming pool areas outside SELV zones and nurseries (13.1)
- Test of resistance of the luminaire cover to static load (13.6.1)
- Torque and shear tests of luminaires in areas with vehicle traffic (13.6.2)
- Checking the marking of the rated load in N and of the maximum surface temperature T (13.5)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 18.11.2026) | PKN cards: PN-EN 60598-2-13:2007 “Oprawy oświetleniowe -- Część 2-13: Wymagania szczegółowe -- Oprawy oświetleniowe wbudowywane w podłoże” — Polish version, published 30-08-2007, 13 pages, KT 4 Lighting Technology, implements EN 60598-2-13:2006 with the corrigendum of December 2006 and IEC 60598-2-13:2006 [IDT], replaces PN-EN 60598-2-13:2006 and its corrigendum AC:2007; amendments: A1:2012 (Polish version, published 18-11-2013 — changed test procedure in 13.6.1 and Figure 2; implements EN 60598-2-13:2006/A1:2012 and IEC 60598-2-13:2006/AMD1:2011), A2:2017-02 (English version, published 07-02-2017 — a new paragraph on photobiological safety before Table A.1; implements EN 60598-2-13:2006/A2:2016 and IEC 60598-2-13:2006/AMD2:2016) and A11:2021-09 (English version, published 13-09-2021 — new Annexes ZA and ZZ; implements EN 60598-2-13:2006/A11:2021); the cards give no withdrawal date. iTeh catalogue: EN 60598-2-13:2006 — published 07.08.2006, status “Published”, stage 90.93 (decision to confirm). |
| Scope (13.1) | ground recessed luminaires, supply up to 1000 V, indoor and outdoor; excluding luminaires for motorised roads and airfields (IEC 61827) |
| Marking (13.5) | rated load in N; maximum surface temperature T in °C (Table 3.1 of IEC 60598-1, column B); connecting box |
| Static load punch (13.6.1, amd. 1) | steel, Ø 50 mm (or luminaire D if smaller), thickness 50 mm; rubber Shore A 65 ± 5, thickness 10 mm |
| Load application (13.6.1) | load tolerance ± 3 %; rate ≤ 5000 N/min; maximum load for 1 min |
| Torque test (13.6.2.1) | 50 N torque force for 1 min on each joint separately (Figure 3: 50 N / 60 s, 1 m bar — example) |
| Criterion after the tests (13.6.1, 13.6.2.1) | conformity requirements of 4.13.1 of IEC 60598-1 (as after the mechanical impact test) |
Standard
- Standard number
- PN-EN 60598-2-13:2007 (Polish version; implements EN 60598-2-13:2006 and IEC 60598-2-13:2006 [IDT]) with amendments A1:2012 (Polish version), A2:2017-02 and A11:2021-09 (English versions)
- Title (PL)
- Oprawy oświetleniowe — Część 2-13: Wymagania szczegółowe — Oprawy oświetleniowe wbudowywane w podłoże
- Title (EN)
- Luminaires — Part 2-13: Particular requirements — Ground recessed luminaires
Step-by-step procedure
-
Inspection and marking
Checking the markings according to Section 3 of IEC 60598-1 and 13.5: rated load in N, maximum surface temperature T, information about the connecting box.
-
Mounting the sample
Sample mounted as in normal use, according to the manufacturer's instructions; punch on the axis of the geometrical centre of the translucent cover.
-
Static load
Uniform increase of the load (≤ 5000 N/min) up to the minimum value from the instructions, held for 1 min within ± 3 %; after the test assessment according to 4.13.1 of IEC 60598-1.
-
Torque and shear
For luminaires for areas with vehicle traffic: 50 N torque force for 1 min on each joint separately (13.6.2.1) and the shear test (13.6.2.2); after the tests — the requirements of 4.13.1 of IEC 60598-1.
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Steel punch with a sheet of rubber (13.6.1, Figure 2) | Ø 50 mm, thickness 50 mm; rubber Shore A 65 ± 5, thickness 10 mm, on the axis of the centre of the translucent cover | — |
| Loading device | Uniform application of the load at ≤ 5000 N/min and holding it within ± 3 % for 1 min | — |
| Shore type A durometer | Checking the rubber hardness of 65 ± 5 Shore A | — |
| Torque test device (Figure 3) | A 50 N force for 60 s applied to a bar (example: 1 m) | — |
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN 60598-2-13:2007 (Polish version; implements EN 60598-2-13:2006 and IEC 60598-2-13:2006 [IDT]) with amendments A1:2012 (Polish version), A2:2017-02 and A11:2021-09 (English versions) — “Luminaires — Part 2-13: Particular requirements — Ground recessed luminaires”.
How does this method work?
The luminaire, mounted as in the ground, is loaded from the top through a Ø 50 mm steel punch with Shore A 65 ± 5 rubber of 10 mm thickness, increasing to the rated load from the instructions (≤ 5000 N/min, held for 1 min), and luminaires for areas with vehicle traffic are additionally subjected to a 50 N torque force for 1 min at each joint and to a shear test. After the tests the luminaire shall comply with 4.
What is the measuring range and accuracy?
STATUS (as of 18.11.2026): PKN cards: PN-EN 60598-2-13:2007 “Oprawy oświetleniowe -- Część 2-13: Wymagania szczegółowe -- Oprawy oświetleniowe wbudowywane w podłoże” — Polish version, published 30-08-2007, 13 pages, KT 4 Lighting Technology, implements EN 60598-2-13:2006 with the corrigendum of December 2006 and IEC 60598-2-13:2006 [IDT], replaces PN-EN 60598-2-13:2006 and its corrigendum AC:2007; amendments: A1:2012 (Polish version, published 18-11-2013 — changed test procedure in 13.6.1 and Figure 2; implements EN 60598-2-13:2006/A1:2012 and IEC 60598-2-13:2006/AMD1:2011), A2:2017-02 (English version, published 07-02-2017 — a new paragraph on photobiological safety before Table A.1; implements EN 60598-2-13:2006/A2:2016 and IEC 60598-2-13:2006/AMD2:2016) and A11:2021-09 (English version, published 13-09-2021 — new Annexes ZA and ZZ; implements EN 60598-2-13:2006/A11:2021); the cards give no withdrawal date. iTeh catalogue: EN 60598-2-13:2006 — published 07.08.2006, status “Published”, stage 90.93 (decision to confirm).; Scope (13.1): ground recessed luminaires, supply up to 1000 V, indoor and outdoor; excluding luminaires for motorised roads and airfields (IEC 61827); Marking (13.5): rated load in N; maximum surface temperature T in °C (Table 3.1 of IEC 60598-1, column B); connecting box; Static load punch (13.6.1, amd. 1): steel, Ø 50 mm (or luminaire D if smaller), thickness 50 mm; rubber Shore A 65 ± 5, thickness 10 mm.
How long does the test take?
The procedure comprises 4 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.
What equipment is required?
Steel punch with a sheet of rubber (13.6.1, Figure 2), Loading device, Shore type A durometer, Torque test device (Figure 3).
Where is this test used?
Ground recessed luminaires up to 1000 V in gardens, yards, carriageways, parking lots, cycleways, footways, pedestrian areas, swimming pool areas outside SELV zones and nurseries (13.1); Test of resistance of the luminaire cover to static load (13.6.1); Torque and shear tests of luminaires in areas with vehicle traffic (13.6.2); Checking the marking of the rated load in N and of the maximum surface temperature T (13.5).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 60598-2-13.