💡 Recessed luminaires and recessed air-handling luminaires: particular requirements — thermal tests in a test recess (suspended ceiling of 12 mm particle board, mineral wool or a box of 19 mm laminated wood), temperature of the supply cable at the hottest point, limits of 100 °C, 130 °C and 150 °C for air-handling luminaires, IP of the parts in the recess and protruding parts; PN-EN IEC 60598-2-2
In short
Particular requirements for recessed luminaires for electrical light sources on supply voltages up to 1 000 V and for recessed air-handling luminaires for use with a ventilation duct or ventilated space (plenum). The test is performed according to PN-EN IEC 60598-2-2:2024-06 (English version; implements EN IEC 60598-2-2:2024 and IEC 60598-2-2:2023 [IDT]); STATUS (as of 24.11.2026): PKN card: PN-EN IEC 60598-2-2:2024-06 — English version, published 24-06-2024, 26 pages, KT 4 (lighting technology), implements EN IEC 60598-2-2:2024 [IDT] and IEC 60598-2-2:2023 [IDT], replaces PN-EN 60598-2-2:2012 (Polish version); the card gives no withdrawal date. The procedure comprises 5 steps; it is used for: Luminaires recessed into a ceiling or a wall, for electrical light sources on supply voltages up to 1 000 V (2.1, Annex B), Recessed air-handling luminaires used with a ventilation duct or ventilated space (plenum) — requirements transferred from IEC 60598-2-19 (2.1, 2.13.4, foreword), Luminaires suitable and not suitable for covering with thermal insulating material or for direct mounting on normally flammable surfaces (2.6.3, 2.6.4, Annex B).
At a glance
- Standard: PN-EN IEC 60598-2-2:2024-06 (English version; implements EN IEC 60598-2-2:2024 and IEC 60598-2-2:2023 [IDT])
- Category: Electronics and EMC
- Procedure steps: 5
- STATUS (as of 24.11.2026): PKN card: PN-EN IEC 60598-2-2:2024-06 — English version, published 24-06-2024, 26 pages, KT 4 (lighting technology), implements EN IEC 60598-2-2:2024 [IDT] and IEC 60598-2-2:2023 [IDT], replaces PN-EN 60598-2-2:2012 (Polish version); the card gives no withdrawal date.
- Scope (2.1): recessed luminaires, supply voltage up to 1 000 V; recessed air-handling luminaires with a ventilation duct or plenum (forced ventilation)
- Symbols (2.6.3, 2.6.4): not for direct mounting on normally flammable surfaces; not for covering with thermally insulating material — at least 25 mm per side
Overview
WHAT THE STANDARD COVERS. According to 2.1 of IEC 60598-2-2:2023 the standard specifies requirements for recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V, and for recessed air-handling luminaires for use with a ventilation duct or ventilated space (plenum); according to the note, “ventilation” in this standard means forced ventilation. An air-handling luminaire is, according to 2.3.1, a luminaire specially designed for use in association with an air conditioning system (the air can pass through the lamp chamber or through separate passages); static operation (2.3.2) is operation without forced supply or extract air, permitting natural convection. The standard is used together with IEC 60598-1 (based on its ninth edition of 2020); the tests from the appropriate sections of Part 1 are carried out in the order listed in Part 2-2 (2.4).
ACCORDING TO THE TEXT OF IEC 60598-2-2:2023 (edition 4.0; two publisher's samples: the official version — foreword and 2.1–2.16; the commented version (CMV) — additionally Annex A and Annex B up to Figure B.3). The standard was prepared by subcommittee IEC SC 34D (luminaires) of IEC TC 34. The fourth edition replaces the third edition of 2011; according to the foreword the main changes are the transfer into Part 2-2 of the requirements for recessed luminaires from IEC 60598-1 and of the requirements for air-handling luminaires from IEC 60598-2-19, and the update of references to Part 1 (no major technical changes, Annex D). Normative references: IEC 60227 and IEC 60245 (PVC- and rubber-insulated cables up to 450/750 V) and IEC 60598-1.
MARKING (2.6). Luminaires with two IP ratings have both visible during installation, clearly assigned to the parts of the luminaire — also where the rating is IP20 or the lower rating is specified as ordinary (2.6.2). Where applicable, the luminaire carries the symbol for luminaires not suitable for direct mounting on normally flammable surfaces (Figure 1) and the symbol for luminaires not suitable for covering with thermally insulating material (Figure 2), at least 25 mm per side, visible during installation, explained on the luminaire or in the manufacturer's instructions (2.6.3, 2.6.4).
WIRING AND PROTECTION AGAINST ELECTRIC SHOCK (2.11, 2.12). Flexible cables for connection to the supply, if supplied by the luminaire manufacturer, shall have mechanical and electrical properties at least equal to the IEC 60227 or IEC 60245 series and withstand without deterioration the highest temperature to which they can be exposed in normal use; this is checked by the tests of 2.13. Parts of the luminaire and components within the ceiling space or cavity shall provide the same protection against electric shock as the parts below the ceiling (according to the note, the ceiling space is regarded as accessible for installation and maintenance).
THERMAL TESTS (2.13). Section 12 of Part 1 applies; the luminaire is mounted and tested according to Annex B. Luminaires with an IP classification greater than IP20 are subjected to the tests 12.4, 12.5, 12.6 and 12.7 of Part 1 after the tests of 9.2 but before those of 9.3 of Section 9 of Part 1. Wiring for connection to the supply that passes into or can touch the luminaire shall not reach an unsafe temperature (2.13.3): the luminaire is connected using the cable provided with it, a cable according to the marking on the luminaire or the manufacturer's instructions, otherwise a PVC cable complying with the IEC 60227 series; the hottest point (along the internal route or on the outer surface of the luminaire) with which the cable is likely to lie in contact in normal service is found, the cable is lightly held against it and the temperature of the insulation at the point of contact is measured according to Annex K of Part 1. Limits according to Table 1: cable provided with the luminaire — the maximum temperature of Table 12.2 of Part 1; cable not provided with the luminaire — the marked temperature, and without such marking — the maximum temperature of Table 12.2 of Part 1 for ordinary PVC not subject to mechanical stress.
AIR-HANDLING LUMINAIRES (2.13.4). The test is made under static operating conditions; stubs for connection of ventilation ducts are connected to the sides or the top of the test box according to the installation instructions. a) Normal operating conditions: the temperature of upward facing surfaces within the main air path shall not exceed 100 °C, and of the surfaces of light sources 150 °C. b) Abnormal operating conditions: the temperature of the convection air leaving the luminaire shall not exceed 100 °C, of upward facing surfaces within the main air path 130 °C, and of the surfaces of light sources 150 °C.
RESISTANCE TO DUST AND MOISTURE (2.14). For luminaires with an IP classification greater than IP20 the order of the Section 9 tests of Part 1 is as specified in 2.13. In recessed luminaires the part in the recess and the parts protruding from the recess are each tested according to their IP classification given in the mounting instructions; a box encapsulating the part in the recess can be necessary. According to the note, the claimed IP rating applies only to the enclosure of the luminaire and does not protect the integrity of seals outside the luminaire (e.g. between the lower and upper parts of the ceiling). Insulation resistance and electric strength and resistance to heat, fire and tracking — according to Sections 10 and 13 of Part 1 (2.15, 2.16).
TEST RECESS (Annex B, normative; text from the CMV sample, in which the whole annex is added in this edition). Annex D of Part 1 applies with additional requirements. The suspended ceiling is made of 12 mm thick general use particle board (note 1 gives boards according to ISO 16893 as an example) with an opening for the luminaire, extending at least 100 mm outside the projection of the luminaire. a) Luminaires suitable for covering with thermal insulating material: the material is tightly fitted to the luminaire and is equivalent to two 10 cm layers of mineral wool with a coefficient of 0,04 W/(m · K) (thinner layers with higher thermal resistivity are permitted); for luminaires with separate parts (e.g. light source enclosure and controlgear enclosure) the spacings recommended by the manufacturer are kept and filled with insulating material (Figure B.1). b) Luminaires not suitable for covering with thermal insulating material: a rectangular box with vertical sides of 19 mm laminated wood and a horizontal top of 12 mm particle board, tightly sealed, is fixed above the luminaire, spaced from it according to the manufacturer's instructions, and without such data touching the luminaire all around; for separate parts — a single box with the recommended spacings or, where the spacing between parts is not specified, separate test recesses for each part (Figure B.2). The ceiling and the inside of the box are painted black with a matt non-metallic paint, and a gap of at least 100 mm is kept between the assembly and the walls, ceiling and floor of the test enclosure. Luminaires for walls are tested in a similar recess with the board placed vertically. Limits: luminaires classified for direct mounting on a normally flammable surface — no part of the insulating material or of the luminaire surface above the ceiling (or of the test recess) shall exceed 90 °C in the normal operation thermal test and 130 °C in the abnormal operation thermal test; for luminaires not suitable for direct mounting on normally flammable surfaces no temperatures of the mounting surface or the recess are measured. Spacings are measured from the extreme positions of settable and adjustable parts (Figure B.3).
AMBIENT TEMPERATURE IN AN INSTALLATION (Annex A). The annex describes the measurement of the ambient temperature in the plane of the ceiling at the mid-point of a typical cavity with all other luminaires and services operating; the rated ambient temperature t a of the luminaire should be at least equal to the measured value. In the CMV sample the designation of this annex is changed between “informative” and “normative” — we do not decide from the text alone which one applies.
WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. The type of recess depends on whether the luminaire is suitable for covering with thermal insulating material (mineral wool against the luminaire or a box), and without stated spacings the box touches the luminaire all around; the cable temperature is measured at the hottest point the cable can touch, and the limit is taken from Table 1 depending on whether the cable was supplied with the luminaire; air-handling luminaires are tested in static operation.
WHAT WE DO NOT GIVE HERE. The requirements of Section 12 of Part 1 (endurance and thermal tests, Table 12.2) and Annex D of Part 1 — they are in IEC 60598-1; the rest of Annex B after Figure B.3, Annex C (significance of t a for air-handling luminaires) and Annex D (changes) — the samples do not cover them.
STATUS (as of 24.11.2026). PKN card: PN-EN IEC 60598-2-2:2024-06 “Oprawy oświetleniowe -- Część 2-2: Wymagania szczegółowe -- Oprawy oświetleniowe wbudowywane i oprawy oświetleniowe wbudowywane napowietrzane” — English version, published 24-06-2024, 26 pages, KT 4 (lighting technology), implements EN IEC 60598-2-2:2024 [IDT] and IEC 60598-2-2:2023 [IDT], replaces PN-EN 60598-2-2:2012 (Polish version); the card gives no withdrawal date. According to the PKN search (24.11.2026), PN-EN 60598-2-2:2012 (Polish version) is withdrawn and replaced by PN-EN IEC 60598-2-2:2024-06.
Method principle
The luminaire is mounted in a test recess (ceiling of 12 mm particle board with mineral wool against the luminaire or with a closed box above it) and tested according to IEC 60598-1 with the requirements of Part 2-2: temperature of the supply cable insulation at the hottest point of contact not above the limit of Table 1, temperatures of the recess and the insulating material (90 °C and 130 °C for luminaires for mounting on normally flammable surfaces), and for air-handling luminaires in static operation — limits of 100 °C, 130 °C and 150 °C.
Applications
- Luminaires recessed into a ceiling or a wall, for electrical light sources on supply voltages up to 1 000 V (2.1, Annex B)
- Recessed air-handling luminaires used with a ventilation duct or ventilated space (plenum) — requirements transferred from IEC 60598-2-19 (2.1, 2.13.4, foreword)
- Luminaires suitable and not suitable for covering with thermal insulating material or for direct mounting on normally flammable surfaces (2.6.3, 2.6.4, Annex B)
- Measurement of the ambient temperature in an existing installation for comparison with t a of the luminaire (Annex A)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 24.11.2026) | PKN card: PN-EN IEC 60598-2-2:2024-06 — English version, published 24-06-2024, 26 pages, KT 4 (lighting technology), implements EN IEC 60598-2-2:2024 [IDT] and IEC 60598-2-2:2023 [IDT], replaces PN-EN 60598-2-2:2012 (Polish version); the card gives no withdrawal date. |
| Scope (2.1) | recessed luminaires, supply voltage up to 1 000 V; recessed air-handling luminaires with a ventilation duct or plenum (forced ventilation) |
| Symbols (2.6.3, 2.6.4) | not for direct mounting on normally flammable surfaces; not for covering with thermally insulating material — at least 25 mm per side |
| Cable temperature (2.13.3, Table 1) | hottest point of contact; cable provided with the luminaire — Table 12.2 of Part 1; cable not provided — marked temperature, without marking — Table 12.2 for ordinary PVC |
| Air-handling luminaires (2.13.4) | static operation; normal: surfaces in the air path ≤ 100 °C, light sources ≤ 150 °C; abnormal: outlet air ≤ 100 °C, surfaces ≤ 130 °C, light sources ≤ 150 °C |
| Test recess (Annex B) | 12 mm particle board, at least 100 mm beyond the projection of the luminaire; mineral wool 2 × 10 cm, 0,04 W/(m · K) or a box: sides of 19 mm laminated wood, top of 12 mm board; matt black paint; gap ≥ 100 mm from the walls of the enclosure |
| Limits in the recess (Annex B) | luminaires for mounting on a normally flammable surface: 90 °C in normal operation, 130 °C in abnormal operation |
| Order of tests (2.13.2, 2.14.2) | luminaires > IP20: tests 12.4–12.7 of Part 1 after the tests of 9.2 and before 9.3 |
Standard
- Standard number
- PN-EN IEC 60598-2-2:2024-06 (English version; implements EN IEC 60598-2-2:2024 and IEC 60598-2-2:2023 [IDT])
- Title (PL)
- Oprawy oświetleniowe — Część 2-2: Wymagania szczegółowe — Oprawy oświetleniowe wbudowywane i oprawy oświetleniowe wbudowywane napowietrzane
- Title (EN)
- Luminaires — Part 2-2: Particular requirements — Recessed luminaires and recessed air-handling luminaires
Step-by-step procedure
-
Tests according to IEC 60598-1
Tests from the appropriate sections of Part 1 in the order listed in Part 2-2; for luminaires > IP20 the thermal tests 12.4–12.7 after the tests of 9.2 and before 9.3 (2.4, 2.13.2, 2.14.2).
-
Test recess
Ceiling of 12 mm particle board; mineral wool against the luminaire (luminaires for covering with insulation) or a box with spacings according to the manufacturer, without data — touching the luminaire; matt black paint; ≥ 100 mm from the walls of the enclosure (Annex B).
-
Supply cable temperature
Connection with a cable according to 2.13.3; finding the hottest point of contact, light pressure of the cable, measurement of the insulation temperature; comparison with Table 1.
-
Air-handling luminaires
Static operation, stubs connected to the box according to the instructions; limits 100 °C / 150 °C (normal operation) and 100 °C / 130 °C / 150 °C (abnormal operation) (2.13.4).
-
Resistance to dust and moisture
The part in the recess and the protruding parts each tested according to their IP rating from the mounting instructions; if necessary a box encapsulating the part in the recess (2.14.3).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Test recess with suspended ceiling (Annex B) | 12 mm general use particle board with an opening for the luminaire, e.g. according to ISO 16893 (note 1) | — |
| Thermal insulating material (Annex B a) | Equivalent of two 10 cm layers of mineral wool with a coefficient of 0,04 W/(m · K) | — |
| Test box (Annex B b) | Sides of 19 mm laminated wood, top of 12 mm particle board, inside painted black with matt non-metallic paint | — |
| Temperature measurement (2.13.3) | Temperature of the cable insulation at the point of contact according to Annex K of Part 1 | — |
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN IEC 60598-2-2:2024-06 (English version; implements EN IEC 60598-2-2:2024 and IEC 60598-2-2:2023 [IDT]) — “Luminaires — Part 2-2: Particular requirements — Recessed luminaires and recessed air-handling luminaires”.
How does this method work?
The luminaire is mounted in a test recess (ceiling of 12 mm particle board with mineral wool against the luminaire or with a closed box above it) and tested according to IEC 60598-1 with the requirements of Part 2-2: temperature of the supply cable insulation at the hottest point of contact not above the limit of Table 1, temperatures of the recess and the insulating material (90 °C and 130 °C for luminaires for mounting on normally flammable surfaces), and for air-handling luminaires in static operation — limits of 100 °C, 130 °C and 150 °C.
What is the measuring range and accuracy?
STATUS (as of 24.11.2026): PKN card: PN-EN IEC 60598-2-2:2024-06 — English version, published 24-06-2024, 26 pages, KT 4 (lighting technology), implements EN IEC 60598-2-2:2024 [IDT] and IEC 60598-2-2:2023 [IDT], replaces PN-EN 60598-2-2:2012 (Polish version); the card gives no withdrawal date.; Scope (2.1): recessed luminaires, supply voltage up to 1 000 V; recessed air-handling luminaires with a ventilation duct or plenum (forced ventilation); Symbols (2.6.3, 2.6.4): not for direct mounting on normally flammable surfaces; not for covering with thermally insulating material — at least 25 mm per side; Cable temperature (2.13.3, Table 1): hottest point of contact; cable provided with the luminaire — Table 12.2 of Part 1; cable not provided — marked temperature, without marking — Table 12.2 for ordinary PVC.
How long does the test take?
The procedure comprises 5 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.
What equipment is required?
Test recess with suspended ceiling (Annex B), Thermal insulating material (Annex B a), Test box (Annex B b), Temperature measurement (2.13.3).
Where is this test used?
Luminaires recessed into a ceiling or a wall, for electrical light sources on supply voltages up to 1 000 V (2.1, Annex B); Recessed air-handling luminaires used with a ventilation duct or ventilated space (plenum) — requirements transferred from IEC 60598-2-19 (2.1, 2.13.4, foreword); Luminaires suitable and not suitable for covering with thermal insulating material or for direct mounting on normally flammable surfaces (2.6.3, 2.6.4, Annex B); Measurement of the ambient temperature in an existing installation for comparison with t a of the luminaire (Annex A).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN IEC 60598-2-2.