💡 Fixed general purpose luminaires: particular requirements — tests according to the sections of IEC 60598-1 in the order of Part 2-1, luminaires with an IP classification greater than IP20 — tests 12.4–12.7 after 9.2 but before 9.3; PN-EN IEC 60598-2-1

Electronics and EMC PN-EN IEC 60598-2-1

In short

Particular requirements for fixed general purpose luminaires for use with electric light sources on supply voltages up to 1 000 V. The test is performed according to PN-EN IEC 60598-2-1:2021-09 (English version 30-09-2021 and Polish version 28-11-2024; implements EN IEC 60598-2-1:2021 and IEC 60598-2-1:2020 [IDT]) with corrigendum PN-EN IEC 60598-2-1:2021-09/Ap1:2023-02; STATUS (as of 25.11.2026): PKN cards: PN-EN IEC 60598-2-1:2021-09 — English version (30-09-2021, 18 pages, with Ap1:2023-02) and Polish version (28-11-2024, 16 pages), KT 4 (lighting technology), implements EN IEC 60598-2-1:2021 [IDT] and IEC 60598-2-1:2020 [IDT], replaces PN-IEC 598-2-1:1994; the cards give no withdrawal date. In the iTeh catalogue: IEC 60598-2-1:2025 (edition 3.0) and prEN IEC 60598-2-1:2024. The procedure comprises 4 steps; it is used for: Fixed general purpose luminaires for electric light sources, supply voltage up to 1 000 V (1.1), Fixed luminaires with an IP classification greater than IP20 — order of the thermal tests and the moisture protection tests (1.13, 1.14).

At a glance

  • Standard: PN-EN IEC 60598-2-1:2021-09 (English version 30-09-2021 and Polish version 28-11-2024; implements EN IEC 60598-2-1:2021 and IEC 60598-2-1:2020 [IDT]) with corrigendum PN-EN IEC 60598-2-1:2021-09/Ap1:2023-02
  • Category: Electronics and EMC
  • Procedure steps: 4
  • STATUS (as of 25.11.2026): PKN cards: PN-EN IEC 60598-2-1:2021-09 — English version (30-09-2021, 18 pages, with Ap1:2023-02) and Polish version (28-11-2024, 16 pages), KT 4 (lighting technology), implements EN IEC 60598-2-1:2021 [IDT] and IEC 60598-2-1:2020 [IDT], replaces PN-IEC 598-2-1:1994; the cards give no withdrawal date. In the iTeh catalogue: IEC 60598-2-1:2025 (edition 3.0) and prEN IEC 60598-2-1:2024.
  • Scope (1.1): fixed general purpose luminaires, electric light sources, supply voltage up to 1 000 V
  • Reference (1.2): IEC 60598-1 only

Overview

WHAT THE STANDARD COVERS. According to 1.1 of IEC 60598-2-1:2020 the standard specifies requirements for fixed general purpose luminaires for use with electric light sources on supply voltages not exceeding 1 000 V. The only normative reference is IEC 60598-1; the definitions are those of Part 1 (1.2, 1.3). Part 2-1 is used together with the latest edition of IEC 60598-1 and its amendments; it was established on the basis of the eighth edition (2014) and Amendment 1 (2017) of Part 1.

ACCORDING TO THE TEXT OF IEC 60598-2-1:2020 (edition 2.0; the publisher's sample covers the foreword, the whole of 1.1–1.16 and Annex A). The standard was prepared by subcommittee IEC SC 34D (luminaires) of IEC TC 34. The second edition replaces the first edition of 1979 and Amendment 1:1987; according to the foreword there are no major technical changes — the scope has been aligned with Part 1 to include all electric light sources, and the references to Part 1 have been updated. Annex A (informative) states that no requirement is more onerous than in the previous edition.

WHAT IT REFERS TO IN PART 1. General test requirements — Section 0, and the tests of the appropriate sections of Part 1 are carried out in the order listed in Part 2-1 (1.4); classification — Section 2 (1.5); marking — Section 3 (1.6); construction — Section 4 (1.7); creepage distances and clearances — Section 11 (1.8); earthing — Section 7 (1.9); terminals — Sections 14 and 15 (1.10); external and internal wiring — Section 5 (1.11); protection against electric shock — Section 8 (1.12); endurance and thermal tests — Section 12 (1.13); resistance to dust, solid objects and moisture — Section 9 (1.14); insulation resistance and electric strength, touch current and protective conductor current — Section 10 (1.15); resistance to heat, fire and tracking — Section 13 (1.16).

ORDER OF TESTS FOR LUMINAIRES ABOVE IP20 (1.13, 1.14). Luminaires with an IP classification greater than IP20 are subjected to the relevant tests of 12.4, 12.5, 12.6 and 12.7 of Section 12 of Part 1 after the tests of 9.2 but before the tests of 9.3 of Section 9 of Part 1; the order of the tests of Section 9 is as specified in 1.13.

WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. For luminaires with an IP classification greater than IP20 the order matters: the endurance and thermal tests are carried out between tests 9.2 and 9.3 of Part 1, not after the whole of Section 9.

NATIONAL CORRIGENDUM. PN-EN IEC 60598-2-1:2021-09/Ap1:2023-02 (approved by the President of PKN on 22 February 2023) adds PN-IEC 598-2-1:1994 to the “Replaces” field on the national title page and a sentence in the national foreword that the standard replaces PN-IEC 598-2-1:1994; it does not change the requirements.

STATUS (as of 25.11.2026). PKN cards: PN-EN IEC 60598-2-1:2021-09 “Oprawy oświetleniowe -- Część 2-1: Wymagania szczegółowe -- Oprawy oświetleniowe stałe ogólnego przeznaczenia” — English version (published 30-09-2021, 18 pages; additional element PN-EN IEC 60598-2-1:2021-09/Ap1:2023-02E) and Polish version (published 28-11-2024, 16 pages), KT 4 (lighting technology), implements EN IEC 60598-2-1:2021 [IDT] and IEC 60598-2-1:2020 [IDT], replaces PN-IEC 598-2-1:1994 (Polish version); the cards give no withdrawal date. The iTeh catalogue already lists IEC 60598-2-1:2025 (edition 3.0, 2025-12) and the draft prEN IEC 60598-2-1:2024 — we do not know the content of the new edition (the sample contains only the title page).

Method principle

A fixed general purpose luminaire is tested according to all relevant sections of IEC 60598-1 in the order given in Part 2-1; for an IP classification greater than IP20, tests 12.4–12.7 of Section 12 are made after the tests of 9.2 but before the tests of 9.3 of Section 9.

Applications

Key parameters

ParameterValue
STATUS (as of 25.11.2026)PKN cards: PN-EN IEC 60598-2-1:2021-09 — English version (30-09-2021, 18 pages, with Ap1:2023-02) and Polish version (28-11-2024, 16 pages), KT 4 (lighting technology), implements EN IEC 60598-2-1:2021 [IDT] and IEC 60598-2-1:2020 [IDT], replaces PN-IEC 598-2-1:1994; the cards give no withdrawal date. In the iTeh catalogue: IEC 60598-2-1:2025 (edition 3.0) and prEN IEC 60598-2-1:2024.
Scope (1.1)fixed general purpose luminaires, electric light sources, supply voltage up to 1 000 V
Reference (1.2)IEC 60598-1 only
Test order above IP20 (1.13, 1.14)tests 12.4, 12.5, 12.6 and 12.7 of Part 1 after the tests of 9.2, before the tests of 9.3
Changes compared with the 1979 edition (foreword, Annex A)scope covers all electric light sources, updated references to Part 1; no more onerous requirements
Corrigendum Ap1:2023-02only adds that the standard replaces PN-IEC 598-2-1:1994

Standard

Standard number
PN-EN IEC 60598-2-1:2021-09 (English version 30-09-2021 and Polish version 28-11-2024; implements EN IEC 60598-2-1:2021 and IEC 60598-2-1:2020 [IDT]) with corrigendum PN-EN IEC 60598-2-1:2021-09/Ap1:2023-02
Title (PL)
Oprawy oświetleniowe — Część 2-1: Wymagania szczegółowe — Oprawy oświetleniowe stałe ogólnego przeznaczenia
Title (EN)
Luminaires — Part 2-1: Particular requirements — Fixed general purpose luminaires

Step-by-step procedure

  1. General requirements and classification

    Sections 0, 2 and 3 of Part 1: general test requirements, classification, marking (1.4–1.6).

  2. Construction and electrical safety

    Sections 4, 11, 7, 14, 15, 5 and 8 of Part 1 (1.7–1.12).

  3. Protection and thermal tests

    Sections 9 and 12 of Part 1; for an IP classification greater than IP20 the order is 9.2 → 12.4–12.7 → 9.3 (1.13, 1.14).

  4. Electrical and material tests

    Section 10 (insulation resistance, electric strength, touch current and protective conductor current) and Section 13 (heat, fire, tracking) of Part 1 (1.15, 1.16).

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-EN IEC 60598-2-1:2021-09 (English version 30-09-2021 and Polish version 28-11-2024; implements EN IEC 60598-2-1:2021 and IEC 60598-2-1:2020 [IDT]) with corrigendum PN-EN IEC 60598-2-1:2021-09/Ap1:2023-02 — “Luminaires — Part 2-1: Particular requirements — Fixed general purpose luminaires”.

How does this method work?

A fixed general purpose luminaire is tested according to all relevant sections of IEC 60598-1 in the order given in Part 2-1; for an IP classification greater than IP20, tests 12.4–12.

What is the measuring range and accuracy?

STATUS (as of 25.11.2026): PKN cards: PN-EN IEC 60598-2-1:2021-09 — English version (30-09-2021, 18 pages, with Ap1:2023-02) and Polish version (28-11-2024, 16 pages), KT 4 (lighting technology), implements EN IEC 60598-2-1:2021 [IDT] and IEC 60598-2-1:2020 [IDT], replaces PN-IEC 598-2-1:1994; the cards give no withdrawal date. In the iTeh catalogue: IEC 60598-2-1:2025 (edition 3.0) and prEN IEC 60598-2-1:2024.; Scope (1.1): fixed general purpose luminaires, electric light sources, supply voltage up to 1 000 V; Reference (1.2): IEC 60598-1 only; Test order above IP20 (1.13, 1.14): tests 12.4, 12.5, 12.6 and 12.7 of Part 1 after the tests of 9.2, before the tests of 9.3.

How long does the test take?

The procedure comprises 4 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.

Where is this test used?

Fixed general purpose luminaires for electric light sources, supply voltage up to 1 000 V (1.1); Fixed luminaires with an IP classification greater than IP20 — order of the thermal tests and the moisture protection tests (1.13, 1.14).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN IEC 60598-2-1.

🔍 Find a laboratory performing this test