💡 Handlamps: particular requirements — Class II or III, impact test against a steel bar from a suspension height of 400 mm and 1 m (3 impacts each at points a, b, c), pull on the covers of 100 N for 1 h, flexing of the cable 20 000 times under a load of 20 N; PN-EN 60598-2-8

Electronics and EMC PN-EN 60598-2-8

In short

Particular requirements for handlamps and similar portable luminaires held in the hand, hooked up or resting on a surface, for use with electric light sources on supply voltages up to 250 V. The test is performed according to PN-EN 60598-2-8:2013-12 (English version; implements EN 60598-2-8:2013 and IEC 60598-2-8:2013 [IDT]); STATUS (as of 25.11.2026): PKN card: PN-EN 60598-2-8:2013-12 — English version, published 17-12-2013, 24 pages, KT 4 (lighting technology), implements EN 60598-2-8:2013 [IDT] and IEC 60598-2-8:2013 [IDT], Directive 2014/35/EU, replaces PN-EN 60598-2-8:2000 with A1:2003 and A2:2008; the card gives no withdrawal date. The procedure comprises 5 steps (about 1 h in total); it is used for: Handlamps and similar portable luminaires held in the hand, hooked up or resting on a surface, up to 250 V (8.1), Handlamps fixed by a wing screw, clip or magnet, and luminaires for inspecting the interior of barrels (8.1), Handlamps with fluorescent lamps and a magnetic ballast or a transformer in the cable (8.7.2, 8.7.5).

At a glance

  • Standard: PN-EN 60598-2-8:2013-12 (English version; implements EN 60598-2-8:2013 and IEC 60598-2-8:2013 [IDT])
  • Category: Electronics and EMC
  • Procedure steps: 5
  • Total time of stages: 1 h
  • STATUS (as of 25.11.2026): PKN card: PN-EN 60598-2-8:2013-12 — English version, published 17-12-2013, 24 pages, KT 4 (lighting technology), implements EN 60598-2-8:2013 [IDT] and IEC 60598-2-8:2013 [IDT], Directive 2014/35/EU, replaces PN-EN 60598-2-8:2000 with A1:2003 and A2:2008; the card gives no withdrawal date.
  • Scope (8.1): handlamps and similar portable luminaires, supply voltage up to 250 V
  • Class (8.5.1): II or III

Overview

WHAT THE STANDARD COVERS. According to 8.1 of IEC 60598-2-8:2013 the standard specifies requirements for handlamps and similar portable luminaires which are held in the hand, hooked up or resting on a surface, for use with electric light sources on supply voltages not exceeding 250 V; it also covers handlamps that can be fixed to a support by a wing screw, clip or magnet, and luminaires for inspecting the interior of barrels. A handlamp is, according to 8.3.1, a luminaire with a handle and a flexible cable or cord, intended to be moved frequently while connected to the supply; the standard distinguishes rewirable handlamps (type X or Y attachment), non-rewirable handlamps (type Z) and sealed handlamps, in which the lamp cannot be replaced without destroying the handlamp (8.3.2–8.3.4). The standard is read together with IEC 60598-1.

ACCORDING TO THE TEXT OF IEC 60598-2-8:2013 (edition 3.0; the publisher's sample covers the foreword and clauses 8.1–8.11.4.1). The standard was prepared by subcommittee IEC SC 34D (luminaires) of IEC TC 34. The third edition replaces the second edition of 1996 and its Amendments 1 (2000) and 2 (2007). According to the foreword, the contradiction introduced by Amendment 2 was removed — the requirement that a handlamp is always a rough service luminaire (which according to 4.13.4 of Part 1 would always mean IP54) contradicted clauses accepting ordinary luminaires (e.g. 8.11.1, 8.11.2, 8.13.1) — as was the contradiction between 8.7.1 and 8.7.2 about the material of the protective cover. The standard was established on the basis of the seventh edition (2008) of IEC 60598-1. References: IEC 60227, IEC 60245 (rubber-insulated cables) and IEC 60598-1.

SAMPLES (8.4). The third paragraph of 0.4.2 of Part 1 does not apply. In general four samples are needed: three for the tests of 8.7.6, the fourth for the other tests; all four undergo the test for rough service hand-held luminaires of 4.13.4 b) of Part 1. With a rubber protection cover an additional sample is needed for the test of 8.13.1. From a range, a representative complete set with the most unfavourable combination is tested.

CLASSIFICATION AND MARKING (8.5, 8.6). Handlamps are Class II or III and are divided into rewirable and non-rewirable handlamps. The Class II or III symbol, the rated voltage of Class III handlamps and the symbol for the degree of protection against dust and moisture are placed on the outside (visibility through a translucent cover is sufficient); the maximum rated wattage shall not be marked in paint or ink, even when protected by varnish (8.6.1). With replaceable lamps and type X attachment, instructions for opening and closing are marked on the protective cover (8.6.2).

CONSTRUCTION (8.7). Shell and handle of insulating material (8.7.1). The lamp is protected by a grid, translucent cover or similar means, rigidly fixed and not removable by hand; during lamp replacement it remains attached (e.g. by a hinge or chain) unless an automatic switch interrupts operation when it is removed. The distance between the glass of a tungsten filament lamp, a tubular fluorescent lamp or a protective glass and a plane through the outside of two adjacent bars of a grid or cover shall be at least 3 mm. A suspension hook is loaded with a weight twice the weight of the luminaire including cable, ballast or transformer; hung on a 1 mm ∅ metal bar it shall not deform so that the luminaire slips off (8.7.2). No resistive ballasts or resistive cables for discharge lamps (8.7.3); lampholders for tungsten filament lamps locked against rotation by at least two independent means, one of them operable only with a tool (8.7.4); a ballast or transformer in the cable — not more than 1 m from the plug and with a suspension hook (8.7.5).

MECHANICAL STRENGTH (8.7.6). The tests of 4.13 of Part 1 do not apply except 4.13.4 b). Grids and covers are pulled with 100 N for 1 h at the parts which, when loose, would allow current-carrying parts to be touched; for sealed handlamps additionally a torque of 10 Nm (8.7.6.1). Impact test (8.7.6.2): the handlamp with a cable according to 8.11.2, without lamp, is suspended by its cable so that point “a” (Figure 1) rests against the corner of a 40 mm × 40 mm × 5 mm steel angle bar with the corner rounded to a radius of 5 mm, mounted on a wall of brick, stone or concrete; the point of suspension is 400 mm above the bar. The handlamp is drawn away in a plane perpendicular to the wall until the cable is horizontal and released three times; then three impacts each at points “b” and “c”. After this test the handlamp shall show no damage impairing safety or further use; the whole test is repeated with the point of suspension 1 m above the bar. The means protecting the lamp shall not have loosened, even if deformed; breakage of a protective glass is neglected if it is not the sole protection of the lamp.

TERMINALS AND WIRING (8.10, 8.11). Supply terminals accept conductors of 0,75 mm² to 1,5 mm². Rewirable handlamps have type X attachment, the others type Y or Z; handlamps have no socket-outlets, and appliance inlets are permitted only on ordinary handlamps and with mechanical locking. Cables not lighter than 60227 IEC 53 (ordinary handlamps, cross-section at least 0,75 mm²) and 60245 IEC 57 (others, at least 1 mm²); only one cable entry. A cord guard of insulating material projects at least 25 mm beyond the inlet opening. Flexing test (8.11.4.1): the part with the cable entry is fixed to the oscillating member of an apparatus (Figure 2), the cable is loaded with a force of 20 N and a current derived from the maximum rated wattage and the rated voltage is passed; the member moves through 90° (45° on either side of the vertical), 20 000 flexings at 60 per minute (a flexing = one movement backwards or forwards). After the test not more than 50 % of the strands of a conductor may be broken, and the cable passes the insulation resistance and high-voltage tests of Section 10 of Part 1.

WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. The impact test is done twice — with a suspension height of 400 mm and then 1 m — each time with three impacts at each of the three points; the condition is assessed after each part. In the flexing test each movement in one direction counts as one flexing.

WHAT WE DO NOT GIVE HERE. Clauses 8.11.5–8.11.6 and 8.12–8.16 and Figure 2 with the dimensions of the apparatus — the sample ends with the description of the test of 8.11.4.1.

STATUS (as of 25.11.2026). PKN card: PN-EN 60598-2-8:2013-12 “Oprawy oświetleniowe -- Część 2-8: Wymagania szczegółowe -- Oprawy oświetleniowe ręczne” — English version, published 17-12-2013, 24 pages, KT 4 (lighting technology), implements EN 60598-2-8:2013 [IDT] and IEC 60598-2-8:2013 [IDT], Directive 2014/35/EU, replaces PN-EN 60598-2-8:2000 (Polish version), PN-EN 60598-2-8:2000/A2:2008 (English version) and PN-EN 60598-2-8:2000/A1:2003 (Polish version); the card gives no withdrawal date and no additional elements. The PKN catalogue has no Polish version of PN-EN 60598-2-8:2013-12.

Method principle

The handlamp is tested according to IEC 60598-1 with the requirements of Part 2-8, usually on four samples: the class (II or III), the material of the shell and handle, the lamp protection (distance of at least 3 mm), the strength of the covers (pull of 100 N for 1 h), the impact resistance (free impacts against a steel bar from a suspension of 400 mm and 1 m) and the cable and its guard (20 000 flexings under a load of 20 N with current flowing) are checked.

Applications

Key parameters

ParameterValue
STATUS (as of 25.11.2026)PKN card: PN-EN 60598-2-8:2013-12 — English version, published 17-12-2013, 24 pages, KT 4 (lighting technology), implements EN 60598-2-8:2013 [IDT] and IEC 60598-2-8:2013 [IDT], Directive 2014/35/EU, replaces PN-EN 60598-2-8:2000 with A1:2003 and A2:2008; the card gives no withdrawal date.
Scope (8.1)handlamps and similar portable luminaires, supply voltage up to 250 V
Class (8.5.1)II or III
Lamp protection (8.7.2)distance between the glass and the plane of two adjacent bars of a grid or cover at least 3 mm; hook — weight 2 × luminaire weight on a 1 mm ∅ bar
Pull on covers (8.7.6.1)100 N for 1 h; sealed handlamps — additionally 10 Nm
Impact test (8.7.6.2)steel angle 40 mm × 40 mm × 5 mm, radius 5 mm; suspension 400 mm, then 1 m; 3 impacts each at points a, b, c
Cables (8.11.2)60227 IEC 53 and ≥ 0,75 mm² (ordinary handlamps); 60245 IEC 57 and ≥ 1 mm² (others)
Flexing test (8.11.4.1)load 20 N, angle 90° (±45°), 20 000 flexings, 60/min; not more than 50 % broken strands
Terminals (8.10.1)conductors from 0,75 mm² to 1,5 mm²; cord guard projects ≥ 25 mm

Standard

Standard number
PN-EN 60598-2-8:2013-12 (English version; implements EN 60598-2-8:2013 and IEC 60598-2-8:2013 [IDT])
Title (PL)
Oprawy oświetleniowe — Część 2-8: Wymagania szczegółowe — Oprawy oświetleniowe ręczne
Title (EN)
Luminaires — Part 2-8: Particular requirements — Handlamps

Step-by-step procedure

  1. Samples and classification

    Usually four samples (three for 8.7.6, the fourth for the other tests), all after the test of 4.13.4 b) of Part 1; Class II or III, method of connecting the cable (8.4.2, 8.5).

  2. Marking and construction

    Markings on the outside, maximum wattage not in paint or ink (8.6); insulating shell, lamp protection and 3 mm distance, hook, lampholders, ballast ≤ 1 m from the plug (8.7.1–8.7.5).

  3. Pull on covers

    100 N for 1 h; for sealed handlamps a torque of 10 Nm (8.7.6.1).

    ⏱ Time: 1 h

  4. Impact test

    Suspension 400 mm above the bar, three free impacts each at points a, b, c; assessment; repetition with a suspension of 1 m and assessment (8.7.6.2).

  5. Cable and flexing

    Cable type and cross-section, single entry, cord guard ≥ 25 mm; 20 000 flexings under a load of 20 N with current; then insulation resistance and high voltage according to Section 10 of Part 1 (8.11).

Required equipment and apparatus

EquipmentExampleIndicative price
Steel angle bar 40 mm × 40 mm × 5 mm on a wall (8.7.6.2, Figure 1)Corner rounded to a radius of 5 mm; steel packing block if necessary—
Flexing apparatus with an oscillating member (8.11.4.1, Figure 2)Angle 90°, 60 flexings per minute, cable load 20 N—
Weights and 1 mm ∅ metal bar (8.7.2)Hook test — twice the weight of the luminaire—
Pull and torque apparatus (8.7.6.1)Force 100 N for 1 h, torque 10 Nm—

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-EN 60598-2-8:2013-12 (English version; implements EN 60598-2-8:2013 and IEC 60598-2-8:2013 [IDT]) — “Luminaires — Part 2-8: Particular requirements — Handlamps”.

How does this method work?

The handlamp is tested according to IEC 60598-1 with the requirements of Part 2-8, usually on four samples: the class (II or III), the material of the shell and handle, the lamp protection (distance of at least 3 mm), the strength of the covers (pull of 100 N for 1 h), the impact resistance (free impacts against a steel bar from a suspension of 400 mm and 1 m) and the cable and its guard (20 000 flexings under a load of 20 N with current flowing) are checked.

What is the measuring range and accuracy?

STATUS (as of 25.11.2026): PKN card: PN-EN 60598-2-8:2013-12 — English version, published 17-12-2013, 24 pages, KT 4 (lighting technology), implements EN 60598-2-8:2013 [IDT] and IEC 60598-2-8:2013 [IDT], Directive 2014/35/EU, replaces PN-EN 60598-2-8:2000 with A1:2003 and A2:2008; the card gives no withdrawal date.; Scope (8.1): handlamps and similar portable luminaires, supply voltage up to 250 V; Class (8.5.1): II or III; Lamp protection (8.7.2): distance between the glass and the plane of two adjacent bars of a grid or cover at least 3 mm; hook — weight 2 × luminaire weight on a 1 mm ∅ bar.

How long does the test take?

The times given for the individual stages add up to approximately 1 h. The procedure comprises 5 steps.

What equipment is required?

Steel angle bar 40 mm × 40 mm × 5 mm on a wall (8.7.6.2, Figure 1), Flexing apparatus with an oscillating member (8.11.4.1, Figure 2), Weights and 1 mm ∅ metal bar (8.7.2), Pull and torque apparatus (8.7.6.1).

Where is this test used?

Handlamps and similar portable luminaires held in the hand, hooked up or resting on a surface, up to 250 V (8.1); Handlamps fixed by a wing screw, clip or magnet, and luminaires for inspecting the interior of barrels (8.1); Handlamps with fluorescent lamps and a magnetic ballast or a transformer in the cable (8.7.2, 8.7.5); Type tests on four samples from a range — the most unfavourable set (8.4.2).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 60598-2-8.

🔍 Find a laboratory performing this test