💡 Luminaires with limited surface temperatures (D symbol): particular requirements — degree of protection at least IP4X (IP5X with dust, IP6X with conductive dust), temperature limits of 90 °C on horizontal and 150 °C on vertical surfaces at 1,06 times rated voltage, 115 °C under fault conditions, 150 °C on the glass of the light source; PN-EN 60598-2-24
In short
Particular requirements for luminaires for locations where the temperature of the outer surface must be limited because of the risk of thermal effects, combustion or degradation of materials, but where there is no risk of explosion (explosive gas and dust atmospheres are excluded). The test is performed according to PN-EN 60598-2-24:2014-02 (English version, published 05-02-2014, and Polish version, published 02-09-2015; implements EN 60598-2-24:2013 and IEC 60598-2-24:2013 [IDT]); STATUS (as of 24.11.2026): PKN cards: PN-EN 60598-2-24:2014-02 — English version (published 05-02-2014, 18 pages) and Polish version (published 02-09-2015, 12 pages), KT 4 (lighting technology), implements EN 60598-2-24:2013 [IDT] and IEC 60598-2-24:2013 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-24:2008 (Polish version); the cards give no withdrawal date. The procedure comprises 5 steps; it is used for: Luminaires for locations where the temperature of the outer surface must be limited because of the risk of thermal effects, combustion or degradation of materials, without risk of explosion (24.1), Luminaires for locations according to IEC 60364-4-42: without unusual dust accumulation, with non-conductive dust, with conductive dust (24.5), Checking the degree of protection of the enclosure IP4X, IP5X or IP6X (24.7.1).
At a glance
- Standard: PN-EN 60598-2-24:2014-02 (English version, published 05-02-2014, and Polish version, published 02-09-2015; implements EN 60598-2-24:2013 and IEC 60598-2-24:2013 [IDT])
- Category: Electronics and EMC
- Procedure steps: 5
- STATUS (as of 24.11.2026): PKN cards: PN-EN 60598-2-24:2014-02 — English version (published 05-02-2014, 18 pages) and Polish version (published 02-09-2015, 12 pages), KT 4 (lighting technology), implements EN 60598-2-24:2013 [IDT] and IEC 60598-2-24:2013 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-24:2008 (Polish version); the cards give no withdrawal date.
- Scope (24.1): luminaires with limited outer surface temperature, without risk of explosion; supply voltage ≤ 1 000 V; explosive gas and dust atmospheres excluded
- Marking (24.6): D symbol (Figure 1); in the literature — the intended location according to 24.5
Overview
WHAT THE STANDARD COVERS. According to 24.1 of IEC 60598-2-24:2013 the standard specifies requirements for luminaires intended for use where the necessity of limited temperature on the outer surface exists, due to the risk of thermal effects, combustion or degradation of materials, but where the risk of explosion in the atmosphere does not exist; the luminaires are for use with electric light sources on supply voltages not exceeding 1 000 V. The standard specifically excludes requirements for luminaires for use in explosive gas and dust atmospheres. Dust is, according to 24.4.1, small solid particles in the atmosphere which settle out under their own weight but may remain suspended in air for some time (including dust and grit according to ISO 4225). The standard is used together with IEC 60598-1; the tests from the appropriate sections of Part 1 are carried out in the order listed in Part 2-24 (24.3).
ACCORDING TO THE TEXT OF IEC 60598-2-24:2013 (second edition; the publisher's sample covers the foreword, 24.1–24.16 and the bibliography, i.e. the whole content of the standard). The standard was prepared by subcommittee IEC SC 34D (luminaires) of IEC TC 34. The second edition replaces the first edition of 1997; according to the foreword the main changes are the reduction of the required degree of protection from IP6X to IP4X (to harmonize with the international wiring rules) and the introduction of temperature limits for the glass surface of any light source exposed to the risk of dust. Normative references: IEC 60364-4-42 (protection against thermal effects), IEC 60598-1 and ISO 4225:1994.
CLASSIFICATION AND MARKING (24.5, 24.6). Luminaires are classified according to Section 2 of Part 1 and additionally as suitable for locations according to IEC 60364-4-42: a) where no unusual accumulation of dust is expected, b) where an accumulation of non-conductive dust on the luminaire may be expected, c) where an accumulation of conductive dust may be expected. Luminaires are marked with the D symbol (Figure 1), visible and complying with 3.2 of Part 1; the manufacturer's literature shall make evident for which location according to 24.5 the luminaire is intended.
CONSTRUCTION (24.7). The enclosure has a degree of protection of at least IP4X, in the presence of dust IP5X, and in the presence of conductive dust IP6X; wiring rules may require at least IP5X or IP6X for certain locations (IEC 60364-4-42). Surfaces where dust may accumulate, all surfaces wider than 7,5 mm and non-vertical surfaces shall comply with the requirements for horizontal surfaces; vertical surfaces not complying with the spacing requirements of 24.13 as well (24.7.2). Compliance — inspection.
TEMPERATURE LIMITS (24.13). Section 12 of Part 1 applies. Luminaires with the D symbol are subjected to the tests 12.4, 12.5, 12.6 and 12.7 of Part 1 after the tests of 9.2 but before those of 9.3 of Section 9 of Part 1. Where the gap between vertical surfaces is less than 30 mm, the limit for horizontal surfaces applies. Normal operation (24.13.1): at 1,06 times the rated voltage the temperature of all horizontal surfaces exposed to dust accumulation shall not exceed 90 °C, and of all vertical external surfaces 150 °C; if an outer surface likely to be positioned against part of a building (wall or similar) has a temperature higher than 90 °C but not exceeding 150 °C, the mounting instructions caution against such positioning. The temperature of any part of the glass surface of a light source exposed to dust shall not exceed 150 °C (according to the note, light sources in luminaires rated IP5X or less are expected to be exposed to dust accumulation). Abnormal operation (24.13.2): the requirements of 12.5.1 of Part 1 and 24.13.1. Fault conditions (24.13.3): the requirements of 12.6 of Part 1, and the temperature of horizontal surfaces exposed to dust shall not exceed 115 °C; for vertical external surfaces and glass surfaces of the light source the limit of 24.13.1 applies.
OTHER CLAUSES (24.8–24.16). Creepage distances and clearances, earthing, terminals, wiring, protection against electric shock, insulation resistance and electric strength, and resistance to heat, fire and tracking — according to the relevant sections of Part 1. Resistance to dust and moisture (24.14) — Section 9 of Part 1, and for luminaires with the D symbol in the order of tests of 24.13.
WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. The 90 °C limit applies not only to horizontal surfaces but to every surface where dust may accumulate, every surface wider than 7,5 mm and every non-vertical surface — and also to vertical surfaces less than 30 mm apart; the measurement in normal operation is made at 1,06 times the rated voltage; under fault conditions the limit for horizontal surfaces is 115 °C, but for vertical surfaces and the light source glass it remains 150 °C.
WHAT WE DO NOT GIVE HERE. The tests of Sections 9 and 12 of Part 1 (resistance to dust and moisture, endurance and thermal tests) are not reproduced — they are in IEC 60598-1; the drawing of the D symbol is not reproduced.
STATUS (as of 24.11.2026). PKN cards: PN-EN 60598-2-24:2014-02 “Oprawy oświetleniowe -- Część 2-24: Wymagania szczegółowe -- Oprawy oświetleniowe o ograniczonych temperaturach powierzchni” — English version (published 05-02-2014, 18 pages) and Polish version (published 02-09-2015, 12 pages), KT 4 (lighting technology), implements EN 60598-2-24:2013 [IDT] and IEC 60598-2-24:2013 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-24:2008 (Polish version); the cards give no withdrawal date. The iTeh catalogue (as of 24.11.2026) already lists a new edition IEC 60598-2-24:2026 with corrigendum COR1:2026 — the PKN cards do not show its adoption; the content of this entry refers to the 2013 edition.
Method principle
A luminaire with the D symbol is tested according to IEC 60598-1 with the requirements of Part 2-24: enclosure at least IP4X (IP5X with dust, IP6X with conductive dust), thermal tests 12.4–12.7 of Part 1 after the tests of 9.2 and before 9.3, and the surface temperatures measured at 1,06 times the rated voltage are compared with the limits: 90 °C for horizontal surfaces and those exposed to dust, 150 °C for vertical surfaces and the light source glass, 115 °C for horizontal surfaces under fault conditions.
Applications
- Luminaires for locations where the temperature of the outer surface must be limited because of the risk of thermal effects, combustion or degradation of materials, without risk of explosion (24.1)
- Luminaires for locations according to IEC 60364-4-42: without unusual dust accumulation, with non-conductive dust, with conductive dust (24.5)
- Checking the degree of protection of the enclosure IP4X, IP5X or IP6X (24.7.1)
- Measurement of the temperatures of horizontal and vertical surfaces and of the light source glass in normal and abnormal operation and under fault conditions (24.13)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 24.11.2026) | PKN cards: PN-EN 60598-2-24:2014-02 — English version (published 05-02-2014, 18 pages) and Polish version (published 02-09-2015, 12 pages), KT 4 (lighting technology), implements EN 60598-2-24:2013 [IDT] and IEC 60598-2-24:2013 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-24:2008 (Polish version); the cards give no withdrawal date. |
| Scope (24.1) | luminaires with limited outer surface temperature, without risk of explosion; supply voltage ≤ 1 000 V; explosive gas and dust atmospheres excluded |
| Marking (24.6) | D symbol (Figure 1); in the literature — the intended location according to 24.5 |
| Degree of protection (24.7.1) | at least IP4X; with dust IP5X; with conductive dust IP6X |
| Surfaces treated as horizontal (24.7.2, 24.13) | where dust may accumulate, wider than 7,5 mm, non-vertical, and vertical surfaces with a gap < 30 mm |
| Normal operation (24.13.1) | at 1,06 × rated voltage: horizontal surfaces exposed to dust ≤ 90 °C, vertical external surfaces ≤ 150 °C, glass of a light source exposed to dust ≤ 150 °C |
| Fault conditions (24.13.3) | horizontal surfaces exposed to dust ≤ 115 °C; vertical surfaces and light source glass — limits of 24.13.1 |
| Order of tests (24.13, 24.14) | tests 12.4–12.7 of Part 1 after the tests of 9.2 and before 9.3 |
Standard
- Standard number
- PN-EN 60598-2-24:2014-02 (English version, published 05-02-2014, and Polish version, published 02-09-2015; implements EN 60598-2-24:2013 and IEC 60598-2-24:2013 [IDT])
- Title (PL)
- Oprawy oświetleniowe — Część 2-24: Wymagania szczegółowe — Oprawy oświetleniowe o ograniczonych temperaturach powierzchni
- Title (EN)
- Luminaires — Part 2-24: Particular requirements — Luminaires with limited surface temperatures
Step-by-step procedure
-
Classification and marking
Checking the D symbol and the intended location according to 24.5 in the manufacturer's literature (24.5, 24.6).
-
Construction
Inspection of the degree of protection of the enclosure and of the surfaces that must meet the requirements for horizontal surfaces (24.7).
-
Tests up to 9.2
Section 9 tests of Part 1 up to and including 9.2, before the thermal tests (24.13, 24.14).
-
Thermal tests
Tests 12.4–12.7 of Part 1 at 1,06 × voltage; limits 90 °C (horizontal), 150 °C (vertical, light source glass), 115 °C for horizontal surfaces under fault conditions (24.13.1–24.13.3).
-
Tests 9.3
Further Section 9 tests of Part 1 after the thermal tests (24.13, 24.14).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Surface temperature measurement (24.13) | Horizontal and vertical surfaces of the luminaire and the light source glass; supply at 1,06 × rated voltage | — |
| Dust test equipment (24.7.1, 24.14) | Checking the IP4X, IP5X or IP6X rating according to Section 9 of Part 1 | — |
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN 60598-2-24:2014-02 (English version, published 05-02-2014, and Polish version, published 02-09-2015; implements EN 60598-2-24:2013 and IEC 60598-2-24:2013 [IDT]) — “Luminaires — Part 2-24: Particular requirements — Luminaires with limited surface temperatures”.
How does this method work?
A luminaire with the D symbol is tested according to IEC 60598-1 with the requirements of Part 2-24: enclosure at least IP4X (IP5X with dust, IP6X with conductive dust), thermal tests 12.4–12.
What is the measuring range and accuracy?
STATUS (as of 24.11.2026): PKN cards: PN-EN 60598-2-24:2014-02 — English version (published 05-02-2014, 18 pages) and Polish version (published 02-09-2015, 12 pages), KT 4 (lighting technology), implements EN 60598-2-24:2013 [IDT] and IEC 60598-2-24:2013 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-24:2008 (Polish version); the cards give no withdrawal date.; Scope (24.1): luminaires with limited outer surface temperature, without risk of explosion; supply voltage ≤ 1 000 V; explosive gas and dust atmospheres excluded; Marking (24.6): D symbol (Figure 1); in the literature — the intended location according to 24.5; Degree of protection (24.7.1): at least IP4X; with dust IP5X; with conductive dust IP6X.
How long does the test take?
The procedure comprises 5 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.
What equipment is required?
Surface temperature measurement (24.13), Dust test equipment (24.7.1, 24.14).
Where is this test used?
Luminaires for locations where the temperature of the outer surface must be limited because of the risk of thermal effects, combustion or degradation of materials, without risk of explosion (24.1); Luminaires for locations according to IEC 60364-4-42: without unusual dust accumulation, with non-conductive dust, with conductive dust (24.5); Checking the degree of protection of the enclosure IP4X, IP5X or IP6X (24.7.1); Measurement of the temperatures of horizontal and vertical surfaces and of the light source glass in normal and abnormal operation and under fault conditions (24.13).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 60598-2-24.