💡 Luminaires for swimming pools and similar applications: particular requirements — Class III (12 V AC or 30 V DC), IPX8 in the water and IP54 outside it, impact test 0,7 Nm, corrosion in artificial sea water at (25 ± 2) °C for 14 days, thermal tests in water at ta ± 10 K; PN-EN IEC 60598-2-18

Electronics and EMC PN-EN IEC 60598-2-18

In short

Particular requirements for fixed luminaires intended for use in water or in contact with water — in the basins of swimming pools, fountains, paddling pools and garden pools. The test is performed according to PN-EN IEC 60598-2-18:2023-05 (English version; implements EN IEC 60598-2-18:2022 and IEC 60598-2-18:2022 [IDT]); STATUS (as of 25.11.2026): PKN card: PN-EN IEC 60598-2-18:2023-05 — English version, published 17-05-2023, 22 pages, KT 4 (lighting technology), implements EN IEC 60598-2-18:2022 [IDT] and IEC 60598-2-18:2022 [IDT], replaces PN-EN 60598-2-18:2002 and PN-EN 60598-2-18:2002/A1:2012; the card gives no withdrawal date. The procedure comprises 5 steps (about 15 days in total); it is used for: Fixed luminaires in the basins of swimming pools, fountains, paddling pools and garden pools (18.1), LED luminaires with bus control with a waterproof multi-core cable (18.11.4, 18.11.5, introduction), Corrosion tests of parts in contact with water in artificial sea water (18.7.3).

At a glance

  • Standard: PN-EN IEC 60598-2-18:2023-05 (English version; implements EN IEC 60598-2-18:2022 and IEC 60598-2-18:2022 [IDT])
  • Category: Electronics and EMC
  • Procedure steps: 5
  • Total time of stages: 15 days
  • STATUS (as of 25.11.2026): PKN card: PN-EN IEC 60598-2-18:2023-05 — English version, published 17-05-2023, 22 pages, KT 4 (lighting technology), implements EN IEC 60598-2-18:2022 [IDT] and IEC 60598-2-18:2022 [IDT], replaces PN-EN 60598-2-18:2002 and PN-EN 60598-2-18:2002/A1:2012; the card gives no withdrawal date.
  • Scope (18.1): fixed luminaires in water or in contact with water; not luminaires behind a separate glass panel, nor hand-held or portable luminaires
  • Protection against electric shock (18.5.2): Class III; circuits ≤ 12 V AC or ≤ 30 V DC ripple free

Overview

WHAT THE STANDARD COVERS. According to 18.1 of IEC 60598-2-18:2022 the standard specifies requirements for fixed luminaires intended for use in water or in contact with water, for example in the basins of swimming pools, fountains, paddling pools and garden pools, for use with electric light sources. The electrical installation rules for swimming pools are given in IEC 60364-7-702 (note). The standard does not cover luminaires not in contact with water (e.g. behind a separate glass panel) or hand-held and portable luminaires. References: IEC 60598-1, IEC 60364-7-702 and EN 50525-2-21:2011 (flexible cables with crosslinked elastomeric insulation). Part 2-18 is used together with the latest edition of IEC 60598-1; it was established on the basis of the ninth edition (2020) of Part 1.

ACCORDING TO THE TEXT OF IEC 60598-2-18:2022 (edition 3.0; the publisher's sample covers the foreword, the introduction and clauses 18.1–18.13.3). The standard was prepared by subcommittee IEC SC 34D (luminaires) of IEC TC 34. The third edition replaces the second edition of 1993 and Amendment 1:2011. According to the foreword, among other things the references to Part 1 were updated, some clauses were renumbered, the standard was redrafted to apply to both filament lamps and LED light sources, former 18.5.3 and 18.10.3 were deleted, and 18.11.4 and 18.11.5 allow an alternative waterproof multi-core cable that conforms to the waterproof test of Annexes D and E of EN 50525-2-21:2011 or an equivalent regional standard. According to the introduction, LED luminaires with bus control use multi-core cables for data transmission, for which the H05 RN-F cable is not suitable.

CLASSIFICATION (18.5). The luminaires are Class III and have external and internal circuits operating at voltages not exceeding 12 V AC or 30 V DC ripple free. Parts in contact with the water of a pool or fountain are pressure watertight (IPX8), parts not in contact with water at least dustproof and splashproof (IP54). By manner of mounting, light source changing and supply connection: Category A — luminaires partly in contact with water, connection and light source replacement from the side not in contact with water; Category B — light source replacement from the side in contact with water after partial or complete draining; Category C — luminaires completely removed from the water for light source replacement, where replacement is possible.

MARKING (18.6). Luminaires intended only for use in water are marked “For use only when immersed in water”. The output of the transformer (in volt-amperes) is given on the luminaire or in the installation leaflet. In the instructions the manufacturer gives information on mounting with regard to corrosion (e.g. aluminium and its alloys in contact with concrete, electro-chemical action of dissimilar metals) and takes the requirements of IEC 60364-7-702 into account.

CONSTRUCTION — IMPACT AND CORROSION TESTS (18.7). Parts of the luminaire, including protective glasses, that are in contact with water in normal use are subjected to an impact test with an energy of 0,7 Nm in the direction of the water pressure, in free air (18.7.2). The same parts are immersed in artificial sea water at (25 ± 2) °C for 14 days; afterwards they shall show no signs of corrosion or roughening of their surfaces — traces of corrosion removable by rubbing are ignored (18.7.3). Artificial sea water: solution A — 28,0 g NaCl, 5,0 g MgCl₂·6H₂O, 2,4 g CaCl₂·H₂O in 885 ml of distilled water; solution B — 7,0 g MgSO₄·7H₂O, 0,2 g NaHCO₃ in 100 ml of distilled water. Solution B is added slowly to solution A and well mixed, the mixture is left to stand for 24 h and filtered, and finally the pH is adjusted to between 7 and 8 by adding sodium bicarbonate (NaHCO₃); it is convenient to pass air bubbles through the mixture while the pH stabilizes. The materials of the test device shall have no influence on the result.

EARTHING, WIRING (18.9–18.11). Section 7 of Part 1 (earthing) does not apply. Connecting leads (tails) are not permitted, nor are switches in flexible cables or cords. Category B luminaires have a non-detachable flexible cable or cord at least equivalent in mechanical and electrical properties to cords of type 245 IEC 57 of IEC 245, or an alternative cable complying with Annexes D and E of EN 50525-2-21:2011 or an equivalent regional standard; the same applies to a non-detachable cable of Category C luminaires.

THERMAL TESTS (18.13). The relevant tests of 12.4, 12.5, 12.6 and 12.7 of Part 1 are made after the tests of 9.2 but before the tests of 9.3 of Part 1. For the tests of Section 12 the luminaire is mounted as far as possible as in normal use, according to the manufacturer's instructions; where the orientation can be varied, the one giving the most unfavourable temperatures is chosen. The temperature of the water in front of the luminaire is maintained at ta ± 10 K; a suitable test device for luminaires whose front is in contact with water is shown in Figure 1.

WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. In the corrosion test only traces of corrosion that can be removed by rubbing are ignored; the impact test is done in free air but in the direction in which the water pressure acts on the luminaire. The sea water is prepared from two solutions and is ready only after 24 h, filtering and adjusting the pH to 7–8.

WHAT WE DO NOT GIVE HERE. Figure 1 with the device for thermal tests and the clauses from 18.14 on (resistance to dust and moisture, electric strength, resistance to heat and fire) and Annex A — the sample ends at 18.13.3.

STATUS (as of 25.11.2026). PKN card: PN-EN IEC 60598-2-18:2023-05 “Oprawy oświetleniowe -- Część 2-18: Wymagania szczegółowe -- Oprawy oświetleniowe do basenów pływackich i podobnych zastosowań” — English version, published 17-05-2023, 22 pages, KT 4 (lighting technology), implements EN IEC 60598-2-18:2022 [IDT] and IEC 60598-2-18:2022 [IDT], replaces PN-EN 60598-2-18:2002 (Polish version) and PN-EN 60598-2-18:2002/A1:2012 (English version); the card gives no withdrawal date and no additional elements.

Method principle

The pool luminaire is tested according to IEC 60598-1 with the requirements of Part 2-18: Class III and circuit voltages (12 V AC / 30 V DC) and degrees of protection (IPX8 for parts in water, IP54 for the others) are checked, an impact test of 0,7 Nm is made on the parts in contact with water, a 14-day corrosion test in artificial sea water at (25 ± 2) °C and thermal tests with the water in front of the luminaire at ta ± 10 K.

Applications

Key parameters

ParameterValue
STATUS (as of 25.11.2026)PKN card: PN-EN IEC 60598-2-18:2023-05 — English version, published 17-05-2023, 22 pages, KT 4 (lighting technology), implements EN IEC 60598-2-18:2022 [IDT] and IEC 60598-2-18:2022 [IDT], replaces PN-EN 60598-2-18:2002 and PN-EN 60598-2-18:2002/A1:2012; the card gives no withdrawal date.
Scope (18.1)fixed luminaires in water or in contact with water; not luminaires behind a separate glass panel, nor hand-held or portable luminaires
Protection against electric shock (18.5.2)Class III; circuits ≤ 12 V AC or ≤ 30 V DC ripple free
Degrees of protection (18.5.3)parts in water — IPX8; parts outside water — at least IP54
Categories (18.5.4)A — replacement from the dry side; B — from the water side after draining; C — luminaire removed from the water
Impact test (18.7.2)0,7 Nm in the direction of the water pressure, in free air, parts in contact with water (including protective glasses)
Corrosion (18.7.3)artificial sea water (25 ± 2) °C, 14 days; no corrosion or roughening (traces removable by rubbing are ignored)
Artificial sea water (18.7.3)A: 28,0 g NaCl, 5,0 g MgCl₂·6H₂O, 2,4 g CaCl₂·H₂O in 885 ml; B: 7,0 g MgSO₄·7H₂O, 0,2 g NaHCO₃ in 100 ml; 24 h, filtering, pH 7–8 (NaHCO₃)
Thermal tests (18.13)12.4–12.7 of Part 1 after 9.2, before 9.3; water temperature in front of the luminaire ta ± 10 K

Standard

Standard number
PN-EN IEC 60598-2-18:2023-05 (English version; implements EN IEC 60598-2-18:2022 and IEC 60598-2-18:2022 [IDT])
Title (PL)
Oprawy oświetleniowe — Część 2-18: Wymagania szczegółowe — Oprawy oświetleniowe do basenów pływackich i podobnych zastosowań
Title (EN)
Luminaires — Part 2-18: Particular requirements — Luminaires for swimming pools and similar applications

Step-by-step procedure

  1. Classification and marking

    Class III, circuit voltages, degrees of protection IPX8/IP54, Category A, B or C; marking “For use only when immersed in water”, transformer output, corrosion information in the instructions (18.5, 18.6).

  2. Impact test

    Parts in contact with water, including protective glasses: 0,7 Nm in the direction of the water pressure, in free air (18.7.2).

  3. Preparing artificial sea water

    Solutions A and B, slow mixing, standing for 24 h, filtering, pH 7–8 with sodium bicarbonate (18.7.3).

    ⏱ Time: 24 h

  4. Corrosion test

    Immersion of the parts in contact with water at (25 ± 2) °C for 14 days; assessment of corrosion and roughening (18.7.3).

    ⏱ Time: 14 days • 🌡 Temperature: (25 ± 2) °C

  5. Wiring and thermal tests

    No connecting leads and no switches in cables; cable of type 245 IEC 57 or alternative (Categories B and C); tests 12.4–12.7 after 9.2, before 9.3, mounting as in use, water at ta ± 10 K (18.11, 18.13).

Required equipment and apparatus

EquipmentExampleIndicative price
Impact test apparatus (18.7.2)Impact energy 0,7 Nm—
Thermostated tank for the corrosion test (18.7.3)Artificial sea water (25 ± 2) °C for 14 days; materials with no influence on the result—
pH meter and aeration (18.7.3)Adjusting the pH to 7–8 with sodium bicarbonate; air bubbles help the pH to stabilize—
Thermal test device with water in front of the luminaire (18.13.3, Figure 1)Water temperature ta ± 10 K—

Reagents, media and consumables

ReagentCASDetails
Sodium chloride NaCl—28,0 g in solution A (18.7.3)
Magnesium chloride hexahydrate MgCl₂·6H₂O—5,0 g in solution A (18.7.3)
Calcium chloride CaCl₂·H₂O—2,4 g in solution A; formula as written in the standard (18.7.3)
Magnesium sulfate heptahydrate MgSO₄·7H₂O—7,0 g in solution B (18.7.3)
Sodium bicarbonate NaHCO₃—0,2 g in solution B; also for adjusting the pH to 7–8 (18.7.3)
Distilled water—885 ml (solution A) and 100 ml (solution B) (18.7.3)

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-EN IEC 60598-2-18:2023-05 (English version; implements EN IEC 60598-2-18:2022 and IEC 60598-2-18:2022 [IDT]) — “Luminaires — Part 2-18: Particular requirements — Luminaires for swimming pools and similar applications”.

How does this method work?

The pool luminaire is tested according to IEC 60598-1 with the requirements of Part 2-18: Class III and circuit voltages (12 V AC / 30 V DC) and degrees of protection (IPX8 for parts in water, IP54 for the others) are checked, an impact test of 0,7 Nm is made on the parts in contact with water, a 14-day corrosion test in artificial sea water at (25 ± 2) °C and thermal tests with the water in front of the luminaire at ta ± 10 K.

What is the measuring range and accuracy?

STATUS (as of 25.11.2026): PKN card: PN-EN IEC 60598-2-18:2023-05 — English version, published 17-05-2023, 22 pages, KT 4 (lighting technology), implements EN IEC 60598-2-18:2022 [IDT] and IEC 60598-2-18:2022 [IDT], replaces PN-EN 60598-2-18:2002 and PN-EN 60598-2-18:2002/A1:2012; the card gives no withdrawal date.; Scope (18.1): fixed luminaires in water or in contact with water; not luminaires behind a separate glass panel, nor hand-held or portable luminaires; Protection against electric shock (18.5.2): Class III; circuits ≤ 12 V AC or ≤ 30 V DC ripple free; Degrees of protection (18.5.3): parts in water — IPX8; parts outside water — at least IP54.

How long does the test take?

The times given for the individual stages add up to approximately 15 days. The procedure comprises 5 steps.

What equipment is required?

Impact test apparatus (18.7.2), Thermostated tank for the corrosion test (18.7.3), pH meter and aeration (18.7.3), Thermal test device with water in front of the luminaire (18.13.3, Figure 1).

Where is this test used?

Fixed luminaires in the basins of swimming pools, fountains, paddling pools and garden pools (18.1); LED luminaires with bus control with a waterproof multi-core cable (18.11.4, 18.11.5, introduction); Corrosion tests of parts in contact with water in artificial sea water (18.7.3); Checking mounting categories A, B, C and the markings (18.5.4, 18.6).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN IEC 60598-2-18.

🔍 Find a laboratory performing this test