💡 Aquarium luminaires: particular requirements — at least IPX7 (with IPX4 and IPX2 exceptions for permanently attached luminaires), distance from the maximum water level at least 15 mm, fixing on the glass without movement at 20 N for 1 min, cable at least 1,5 m; PN-EN 60598-2-11
In short
Particular requirements for household aquarium luminaires with electric light sources on supply voltages up to 1 000 V. The test is performed according to PN-EN 60598-2-11:2014-01 (English version; implements EN 60598-2-11:2013 and IEC 60598-2-11:2013 [IDT]) with amendment PN-EN 60598-2-11:2014-01/A1:2023-03 (EN 60598-2-11:2013/A1:2022, IEC 60598-2-11:2013/AMD1:2022 [IDT]); STATUS (as of 26.11.2026): PKN card: PN-EN 60598-2-11:2014-01 — English version (20-01-2014, 20 pages), KT 4 (lighting technology), implements EN 60598-2-11:2013 [IDT] and IEC 60598-2-11:2013 [IDT], replaces PN-EN 60598-2-11:2006; amendment A1:2023-03 (29-03-2023, 16 pages, EN 60598-2-11:2013/A1:2022, IEC 60598-2-11:2013/AMD1:2022); no withdrawal date. In the iTeh catalogue — draft prEN IEC 60598-2-11:2025. The procedure comprises 5 steps (about 1 min in total); it is used for: Household non-permanently attached aquarium luminaires — placed on the tank or the cover frame (11.4.2, 11.7.1), Luminaires permanently attached to the tank or a fixed cover frame, including those mounted on the tank wall — fixing test on glass (11.4.3, 11.7.4), Class III luminaires for operation in contact with water or in water — working voltage up to 12 V RMS or 30 V ripple-free DC (11.7.1).
At a glance
- Standard: PN-EN 60598-2-11:2014-01 (English version; implements EN 60598-2-11:2013 and IEC 60598-2-11:2013 [IDT]) with amendment PN-EN 60598-2-11:2014-01/A1:2023-03 (EN 60598-2-11:2013/A1:2022, IEC 60598-2-11:2013/AMD1:2022 [IDT])
- Category: Electronics and EMC
- Procedure steps: 5
- Total time of stages: 1 min
- STATUS (as of 26.11.2026): PKN card: PN-EN 60598-2-11:2014-01 — English version (20-01-2014, 20 pages), KT 4 (lighting technology), implements EN 60598-2-11:2013 [IDT] and IEC 60598-2-11:2013 [IDT], replaces PN-EN 60598-2-11:2006; amendment A1:2023-03 (29-03-2023, 16 pages, EN 60598-2-11:2013/A1:2022, IEC 60598-2-11:2013/AMD1:2022); no withdrawal date. In the iTeh catalogue — draft prEN IEC 60598-2-11:2025.
- Scope (11.1): household aquarium luminaires, electric light sources, supply voltage up to 1 000 V
- Protection against water (11.7.1, 11.7.2): at least IPX7; permanently attached luminaires in an aquarium with drainage: surfaces at least 15 mm above the maximum level — IPX4, others — IPX2 (where splashes do not reach hazardous parts)
Overview
WHAT THE STANDARD COVERS. According to 11.1 of IEC 60598-2-11:2013 the standard specifies requirements for household aquarium luminaires incorporating electric light sources on supply voltages not exceeding 1 000 V (according to a note, in the USA electrical equipment used on or in aquariums is supplied by voltages not exceeding 300 V). According to the introduction, aquarium luminaires are usually placed on top of the tank, very close to the water, and the aquarium has to be opened frequently (refilling water, feeding) — the requirements are intended to prevent dangerous contact between current-carrying parts and the water during refilling and maintenance and accidental immersion of the luminaire. The standard is read together with IEC 60598-1; the tests of the Part 1 sections are carried out in the order listed in Part 2-11 (11.3).
ACCORDING TO THE TEXT OF IEC 60598-2-11:2013 (edition 2.0, 2013-05; the publisher's sample covers the foreword and clauses 11.1–11.13.2) AND AMENDMENT IEC 60598-2-11:2013/AMD1:2022 (the sample covers the whole text of the amendment). Clauses 11.14–11.16 and Annex A — from the sample of the consolidated version IEC 60598-2-11:2013+AMD1:2022 (CSV). The standard was prepared by subcommittee IEC SC 34D of IEC TC 34. The second edition replaces the first edition of 2005; changes according to the foreword: scope opened to all electric light sources (11.1), clarified definition of a non-permanently attached luminaire (11.4.2), for aquarium luminaires used indoors — cross-section of the external cable at least 0,75 mm² instead of 1,0 mm² (11.11.3).
DEFINITIONS (11.4). Non-permanently attached aquarium luminaire — placed on the tank, on a removable or fixed top cover frame, removable by hand; a luminaire that must be detached from the aquarium for lamp replacement or maintenance is considered non-permanently attached. Permanently attached aquarium luminaire — mounted on the tank or on a fixed top cover frame, removable only with a tool. Independently suspended luminaire — a pendant not permanently attached to the tank. Aquarium — the complete system: tank, luminaire and, if applicable, the top cover frame.
MARKING (11.6). Where the design of the aquarium allows water to reach the luminaire — information or a symbol (Figure 1, "min. ... mm") on the minimum distance of the luminaire from the maximum water level, at least 15 mm (11.6.1). Portable external parts (e.g. ballast units) with protection against moisture lower than IPX7 — the warning "Shall not be positioned on or into the cover frame" (11.6.2). According to amendment AMD1, a luminaire foreseen to be opened for maintenance carries an instruction visible from outside, "Disconnect supply before opening the luminaire for maintenance" (11.6.3; in the 2013 edition the marking applied to every aquarium luminaire). A permanently attached luminaire delivered separately for mounting on the wall of the tank — permissible wall thickness of the tank in the instructions (11.6.4).
CONSTRUCTION (11.7, wording according to AMD1 in 11.7.1, 11.7.2 and 11.7.4). Non-permanently attached luminaires — at least IPX7; only Class III luminaires with a working voltage up to 12 V RMS or 30 V ripple-free DC may be in contact with water or submersed (11.7.1). Permanently attached luminaires — at least IPX7, with the exception: in an aquarium with drainage apertures or a cut-off mechanism, surfaces located at least 15 mm above the maximum water level in case of overfilling — at least IPX4, and the other surfaces — at least IPX2 if the position of the luminaire prevents contact of water splashes during refilling with hazardous parts (11.7.2). Portable external parts in the supply cable (switches, ballasts) need not have the IP rating of the luminaire if the cable between the luminaire and the part is at least 1,0 m and between the part and the plug not more than 0,5 m (11.7.3). Fixing test (11.7.4): a force is applied for 1 min in the most onerous direction to a permanently attached luminaire intended for direct mounting on the wall of the tank; the fixing mechanism is mounted on test aquarium "walls" of ordinary window glass of the minimum and maximum thickness specified by the manufacturer; at a pull of 20 N the mechanism shall not start moving on the glass. A switch in the luminaire — double-pole, except for Class III luminaires (11.7.5).
DISTANCES, WIRING (11.8–11.11). Creepage distances and clearances according to Section 11 of Part 1, luminaires for applications in impulse withstand category II. The luminaire has a fixed flexible cable and a plug; cable at least 1,5 m unless 11.7.3 applies (11.11.1). The plug need not have the degree of protection of the luminaire if this differs from IP2X (11.11.2). Luminaires other than ordinary, clearly specified for indoor use only, may have PVC supply cables with conductors of at least 0,75 mm²; for SELV cables — the requirements of IEC 60598-1 (sentence added by AMD1) (11.11.3).
THERMAL AND INGRESS TESTS (11.13, 11.14). According to AMD1 luminaires are subjected to the tests of 12.4, 12.5, 12.6 and 12.7 of Part 1 (in the 2013 edition: 12.4, 12.5 and 12.6) after the tests of 9.2 but before the tests of 9.3 of Section 9 of Part 1 (11.13.1). The maximum water level is represented by a 20 mm thick matt black painted board, on which a matt black 20 mm wide wooden frame gives the distance of the water from the luminaire according to 11.6.1, and the aquarium cover frame with the luminaire fitted is laid onto this frame (11.13.2). The IPX2 test is performed in the closed position (cover over the top of the aquarium, permanently attached luminaire in normal operating position), the IPX4 test — in the opened position (maximum distance to the water); in the IPX4 test the surfaces designed for IPX2 are protected by additional covers (11.14.2 according to AMD1).
ANNEX A (normative). Protective shield of luminaires with metal halide lamps against UV radiation: Annex P of IEC 60598-1 applies, except for the inside of the aquarium.
WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. The order of tests is changed: the thermal tests 12.4–12.7 of Part 1 are carried out between the tests of 9.2 and 9.3; performing them separately, after the ingress tests, does not reproduce the situation of the standard. In the IPX4 test the surfaces designed for IPX2 must not be left uncovered.
WHAT WE DO NOT GIVE HERE. The content of clauses 11.15 (insulation resistance and electric strength) and 11.16 (resistance to heat, fire and tracking) beyond the reference to Sections 10 and 13 of Part 1 — Part 2-11 has no additional requirements for them. The PKN search (as of 26.11.2026) lists no Polish language version — only the English version of the standard and of the amendment.
STATUS (as of 26.11.2026). PKN card: PN-EN 60598-2-11:2014-01 "Oprawy oświetleniowe -- Część 2-11: Wymagania szczegółowe -- Oprawy oświetleniowe do akwarium" — English version (published 20-01-2014, 20 pages), KT 4 (lighting technology), implements EN 60598-2-11:2013 [IDT] and IEC 60598-2-11:2013 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-11:2006 (Polish version), additional element: PN-EN 60598-2-11:2014-01/A1:2023-03 (published 29-03-2023, 16 pages, implements EN 60598-2-11:2013/A1:2022 [IDT] and IEC 60598-2-11:2013/AMD1:2022 [IDT]); the cards give no withdrawal date. The iTeh catalogue lists the draft prEN IEC 60598-2-11:2025.
Method principle
The luminaire is tested according to IEC 60598-1 in the order of the Part 1 sections, with the additional requirements of Part 2-11: the protection against ingress of water (at least IPX7, or IPX4/IPX2 for surfaces of permanently attached luminaires), the marking of the distance from water (at least 15 mm), the fixing on the glass (no movement at 20 N for 1 min) and the cable (at least 1,5 m) are checked, and the thermal tests 12.4–12.7 of Part 1 are carried out between the tests of 9.2 and 9.3, on a board and frame representing the water level.
Applications
- Household non-permanently attached aquarium luminaires — placed on the tank or the cover frame (11.4.2, 11.7.1)
- Luminaires permanently attached to the tank or a fixed cover frame, including those mounted on the tank wall — fixing test on glass (11.4.3, 11.7.4)
- Class III luminaires for operation in contact with water or in water — working voltage up to 12 V RMS or 30 V ripple-free DC (11.7.1)
- Luminaires with metal halide lamps — UV shield according to Annex P of Part 1 (Annex A)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 26.11.2026) | PKN card: PN-EN 60598-2-11:2014-01 — English version (20-01-2014, 20 pages), KT 4 (lighting technology), implements EN 60598-2-11:2013 [IDT] and IEC 60598-2-11:2013 [IDT], replaces PN-EN 60598-2-11:2006; amendment A1:2023-03 (29-03-2023, 16 pages, EN 60598-2-11:2013/A1:2022, IEC 60598-2-11:2013/AMD1:2022); no withdrawal date. In the iTeh catalogue — draft prEN IEC 60598-2-11:2025. |
| Scope (11.1) | household aquarium luminaires, electric light sources, supply voltage up to 1 000 V |
| Protection against water (11.7.1, 11.7.2) | at least IPX7; permanently attached luminaires in an aquarium with drainage: surfaces at least 15 mm above the maximum level — IPX4, others — IPX2 (where splashes do not reach hazardous parts) |
| In water (11.7.1) | Class III only, working voltage up to 12 V RMS or 30 V ripple-free DC |
| Distance from water (11.6.1) | at least 15 mm; symbol "min. ... mm" or information |
| Fixing (11.7.4) | force for 1 min in the most onerous direction; window glass of the manufacturer's minimum and maximum thickness; no movement at 20 N |
| Parts in the cable (11.7.3) | without the IP rating of the luminaire if the cable luminaire–part is at least 1,0 m and part–plug not more than 0,5 m |
| Cable (11.11) | flexible, fixed, with plug, at least 1,5 m; luminaires for indoor use only (other than ordinary) — PVC, at least 0,75 mm² |
| Order of tests (11.13.1) | tests 12.4, 12.5, 12.6 and 12.7 of Part 1 after 9.2 but before 9.3 |
| Water level in thermal tests (11.13.2) | matt black 20 mm board + matt black 20 mm wide frame |
Standard
- Standard number
- PN-EN 60598-2-11:2014-01 (English version; implements EN 60598-2-11:2013 and IEC 60598-2-11:2013 [IDT]) with amendment PN-EN 60598-2-11:2014-01/A1:2023-03 (EN 60598-2-11:2013/A1:2022, IEC 60598-2-11:2013/AMD1:2022 [IDT])
- Title (PL)
- Oprawy oświetleniowe — Część 2-11: Wymagania szczegółowe — Oprawy oświetleniowe do akwarium
- Title (EN)
- Luminaires — Part 2-11: Particular requirements — Aquarium luminaires
Step-by-step procedure
-
Classification and marking
Classification according to Section 2 of Part 1 (11.5); symbol or information on the distance from water (at least 15 mm), warnings for external parts and the instruction to disconnect the supply (11.6).
-
Construction
IP rating according to the type of luminaire (11.7.1, 11.7.2), parts in the cable (11.7.3), double-pole switch except for Class III (11.7.5).
-
Fixing test
Mechanism on window glass of the minimum and maximum thickness, force for 1 min in the most onerous direction; no movement at 20 N (11.7.4).
-
Thermal and ingress tests
Test 9.2 of Part 1, then tests 12.4–12.7 on the 20 mm board with the 20 mm frame (11.13), then 9.3; IPX2 in the closed position, IPX4 in the opened position with IPX2 surfaces covered (11.14).
-
Remaining sections of Part 1
Distances (impulse category II), earthing, terminals, wiring (at least 1,5 m), protection against electric shock, insulation resistance, resistance to heat and fire (11.8–11.16); with metal halide lamps — Annex P of Part 1 (Annex A).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Test aquarium with walls of ordinary window glass (11.7.4) | Minimum and maximum wall thickness specified by the manufacturer | — |
| Force gauge or 20 N weight (11.7.4) | Force for 1 min in the most onerous direction | — |
| Matt black 20 mm thick board and 20 mm wide frame (11.13.2) | Representation of the maximum water level in the thermal tests | — |
| Equipment for IPX2, IPX4 and IPX7 tests according to Section 9 of Part 1 (11.14) | IPX2 in the closed position, IPX4 in the opened position, with IPX2 surfaces covered | — |
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN 60598-2-11:2014-01 (English version; implements EN 60598-2-11:2013 and IEC 60598-2-11:2013 [IDT]) with amendment PN-EN 60598-2-11:2014-01/A1:2023-03 (EN 60598-2-11:2013/A1:2022, IEC 60598-2-11:2013/AMD1:2022 [IDT]) — “Luminaires — Part 2-11: Particular requirements — Aquarium luminaires”.
How does this method work?
The luminaire is tested according to IEC 60598-1 in the order of the Part 1 sections, with the additional requirements of Part 2-11: the protection against ingress of water (at least IPX7, or IPX4/IPX2 for surfaces of permanently attached luminaires), the marking of the distance from water (at least 15 mm), the fixing on the glass (no movement at 20 N for 1 min) and the cable (at least 1,5 m) are checked, and the thermal tests 12.4–12.
What is the measuring range and accuracy?
STATUS (as of 26.11.2026): PKN card: PN-EN 60598-2-11:2014-01 — English version (20-01-2014, 20 pages), KT 4 (lighting technology), implements EN 60598-2-11:2013 [IDT] and IEC 60598-2-11:2013 [IDT], replaces PN-EN 60598-2-11:2006; amendment A1:2023-03 (29-03-2023, 16 pages, EN 60598-2-11:2013/A1:2022, IEC 60598-2-11:2013/AMD1:2022); no withdrawal date. In the iTeh catalogue — draft prEN IEC 60598-2-11:2025.; Scope (11.1): household aquarium luminaires, electric light sources, supply voltage up to 1 000 V; Protection against water (11.7.1, 11.7.2): at least IPX7; permanently attached luminaires in an aquarium with drainage: surfaces at least 15 mm above the maximum level — IPX4, others — IPX2 (where splashes do not reach hazardous parts); In water (11.7.1): Class III only, working voltage up to 12 V RMS or 30 V ripple-free DC.
How long does the test take?
The times given for the individual stages add up to approximately 1 min. The procedure comprises 5 steps.
What equipment is required?
Test aquarium with walls of ordinary window glass (11.7.4), Force gauge or 20 N weight (11.7.4), Matt black 20 mm thick board and 20 mm wide frame (11.13.2), Equipment for IPX2, IPX4 and IPX7 tests according to Section 9 of Part 1 (11.14).
Where is this test used?
Household non-permanently attached aquarium luminaires — placed on the tank or the cover frame (11.4.2, 11.7.1); Luminaires permanently attached to the tank or a fixed cover frame, including those mounted on the tank wall — fixing test on glass (11.4.3, 11.7.4); Class III luminaires for operation in contact with water or in water — working voltage up to 12 V RMS or 30 V ripple-free DC (11.7.1); Luminaires with metal halide lamps — UV shield according to Annex P of Part 1 (Annex A).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 60598-2-11.