💡 Luminaires for stage lighting and television, film and photographic studios: particular requirements — hanger (stirrup) loaded with six times the weight of the luminaire for 1 h, secondary suspension — 30 free falls from a height of 300 mm, mesh in front of a glass bulb lamp (openings 8, 12 or 25 mm), impact 0,5 Nm; PN-EN IEC 60598-2-17
In short
Particular requirements for stage, television, film and photographic studio luminaires (including spot and floodlighting projectors), for use outdoors and indoors, with electric light sources on supply voltages up to 1 000 V. The test is performed according to PN-EN IEC 60598-2-17:2018-05 (English version, published 28-05-2018; implements EN IEC 60598-2-17:2018 and IEC 60598-2-17:2017 [IDT]); STATUS (as of 26.11.2026): PKN card: PN-EN IEC 60598-2-17:2018-05 — English version (28-05-2018, 20 pages), KT 4 (lighting technology), implements EN IEC 60598-2-17:2018 [IDT] and IEC 60598-2-17:2017 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-17:2002; the card gives no withdrawal date. The procedure comprises 5 steps (about 1 h in total); it is used for: Stage and studio luminaires (television, film, photography), including spot and floodlighting projectors, indoors and outdoors, up to 1 000 V (17.1), Luminaires with high-intensity discharge lamps and ignitors — working voltage UR = US / 4,6, opening time warning (17.6.5, 17.7.1, 17.7.2), Luminaires with glass bulb lamps — retention of fragments, meshes and shields (17.7.3).
At a glance
- Standard: PN-EN IEC 60598-2-17:2018-05 (English version, published 28-05-2018; implements EN IEC 60598-2-17:2018 and IEC 60598-2-17:2017 [IDT])
- Category: Electronics and EMC
- Procedure steps: 5
- Total time of stages: 1 h
- STATUS (as of 26.11.2026): PKN card: PN-EN IEC 60598-2-17:2018-05 — English version (28-05-2018, 20 pages), KT 4 (lighting technology), implements EN IEC 60598-2-17:2018 [IDT] and IEC 60598-2-17:2017 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-17:2002; the card gives no withdrawal date.
- Scope (17.1): stage, television, film and photographic luminaires (with spot and floodlighting projectors), indoors and outdoors, supply voltage up to 1 000 V
- Working voltage with ignitor (17.7.1): UR = US / 4,6; above 1 000 V — opening only with a tool or an automatic switch on all poles
Overview
WHAT THE STANDARD COVERS. According to 17.1 of IEC 60598-2-17:2017 the standard specifies requirements for stage, television, film and photographic studio luminaires (including spot and floodlighting projectors) for use outdoors and indoors, with electric light sources on supply voltages not exceeding 1 000 V. According to the note, a hanger (stirrup) is part of the luminaire, while tripods, telescopic booms and suspensions are not; ballasts are built in or mounted separately. The standard is read together with IEC 60598-1; the tests of the Part 1 sections are carried out in the order listed in Part 2-17 (17.4).
ACCORDING TO THE TEXT OF IEC 60598-2-17:2017 (second edition; the publisher's sample covers the foreword and the whole normative text, clauses 17.1–17.16). The standard was prepared by subcommittee IEC SC 34D of IEC TC 34. The second edition replaces the first edition of 1984 and Amendment 2:1990; changes according to the foreword: a) scope extended to electric light sources (instead of tungsten filament, tubular fluorescent and other discharge lamps), b) with many LED luminaires with a non-replaceable light source, a light source without a glass bulb or with low operating temperature, the relevant clauses apply only to luminaires with a replaceable light source, with a glass bulb lamp or with high surface temperature. The standard was established on the basis of the eighth edition (2014) of IEC 60598-1.
MARKING (17.6). Where the design restricts use: indication of the "top" of the luminaire, the positions or range of angles of use and the mounting arrangements (17.6.1). On the exterior of luminaires with replaceable light sources: "Disconnect electrically before re-lamping" and "CAUTION − Hot Lamp" (17.6.2). Rated maximum ambient temperature ta (17.6.3). Minimum distances from flammable materials to all exterior surfaces (17.6.4). Luminaires for certain high-intensity discharge lamps — the warning "DO NOT OPEN FOR X SECONDS AFTER SWITCHING OFF", X determined by the manufacturer (17.6.5). Where the exterior exceeds 70 °C under normal operating conditions — marking of the highest exterior surface temperature (17.6.6). Instructions: shields, lenses and UV screens are changed when visibly damaged (cracks, deep scratches), the lamp — when damaged or thermally deformed; the luminaire is intended for professional use only (17.6.7).
CONSTRUCTION (17.7). It shall not be possible to insert a lamp into a live lampholder — the requirement does not apply to luminaires intended only for professional use; where the working voltage calculated from UR = US / 4,6 (UR — effective value of the working voltage, US — peak value of the pulse voltage of the ignitor) exceeds 1 000 V, the luminaire can be opened only with a tool or has an automatic switch interrupting all poles of the supply (17.7.1). Luminaires for high-intensity discharge lamps with an explosion risk declared by the lamp manufacturer — a device preventing immediate access to the lamp after switching off, or marking according to 17.6.5 (17.7.2). Luminaires with a glass bulb lamp retain particles of glass or quartz: openings through which particles could fall under gravity retain fragments larger than 3 mm; through other openings fragments cannot leave by a direct path — a mesh with openings not exceeding 8 mm or a labyrinth is deemed to comply; with a protective glass shield in front of the lamp — a mesh with openings up to 12 mm in front of that shield; with a shield in the form of a single lens — up to 25 mm; a multi-lens objective needs no mesh. Shields shall withstand the operating temperature and their clamping means hold a broken shield in position; checked by inspection and by the test of 4.21.4 of Part 1 with an impact energy of 0,5 Nm (17.7.3). Hanger (stirrup) — the bearing parts support six times the weight of the luminaire without permanent deformation and are made of non-combustible material (e.g. steel); parts carrying a proportion of the weight — six times that proportion; the connection between hanger and luminaire is locked against loosening; test: six times the weight of the luminaire for 1 h, after the test no permanent deformation and no damage impairing safety (17.7.4). Removable accessories (colour frames, barndoors), when properly inserted, cannot fall out in any position of the luminaire (17.7.5). Secondary suspension — required except for floor-mounted and hand-held luminaires; if the primary suspension fails, no part of the luminaire may fall; test: the end of the secondary suspension is fixed, the luminaire hangs on it alone, is raised vertically by 300 mm and allowed to fall freely, 30 times; the suspension shall not fail and nothing may fall (17.7.6).
TERMINALS, WIRING, TESTS (17.8–17.16). Distances according to Section 11, earthing — Section 7, terminals — Sections 14 and 15 of Part 1, without spring-type screwless terminals of type b shown in Figure 18 of Part 1 (17.10). External and internal wiring of Class I and II luminaires: at least 0,75 mm² for currents above 2 A up to 3 A and at least 1,5 mm² above 3 A (17.11.1); plugs and sockets for connection to separate controlgear shall not be interchangeable with mains ones if direct connection to the mains is dangerous or may damage the surroundings (17.11.2). Luminaires with an IP classification greater than IP20 are subjected to the tests of 12.4, 12.5, 12.6 and 12.7 of Part 1 after the tests of 9.2 but before the tests of 9.3 (17.13.1, 17.14); the housing temperature shall not exceed the value marked according to 17.6.6 (17.13.2). Protection against electric shock, insulation resistance, electric strength, touch current and protective conductor current, resistance to heat, fire and tracking — according to Sections 8, 10 and 13 of Part 1.
WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. The requirements concerning glass bulb lamps and high surface temperatures apply only to luminaires concerned (replaceable light sources, glass bulb, high temperature) — they are not automatically transferred to LED luminaires with a non-replaceable light source; conversely, for a luminaire with a glass bulb lamp only a multi-lens objective allows no mesh. The load in the hanger test is six times the weight of the luminaire (or of the proportion carried by the given part).
WHAT WE DO NOT GIVE HERE. The content of the Part 1 sections to which the standard refers (general requirements for luminaires), including the procedure of the test of 4.21.4 of Part 1 — Part 2-17 gives only the impact energy of 0,5 Nm.
STATUS (as of 26.11.2026). PKN card: PN-EN IEC 60598-2-17:2018-05 "Oprawy oświetleniowe -- Część 2-17: Wymagania szczegółowe -- Oprawy do oświetlenia scenicznego oraz do studiów telewizyjnych i filmowych (zewnętrznych i wewnętrznych)" — English version (published 28-05-2018, 20 pages), KT 4 (lighting technology), implements EN IEC 60598-2-17:2018 [IDT] and IEC 60598-2-17:2017 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-17:2002 (English version), ICS 97.200.10 and 29.140.20; the card gives no withdrawal date or additional elements.
Method principle
The luminaire is tested according to IEC 60598-1 in the order of the Part 1 sections, with the additional requirements of Part 2-17: the hanger is loaded with six times the weight of the luminaire for 1 h, the secondary suspension is checked by 30 free falls of the luminaire from a height of 300 mm, shields in front of a glass bulb lamp — by an impact of 0,5 Nm according to 4.21.4 of Part 1, and luminaires with an IP classification greater than IP20 undergo the thermal tests 12.4–12.7 of Part 1 between the tests of 9.2 and 9.3.
Applications
- Stage and studio luminaires (television, film, photography), including spot and floodlighting projectors, indoors and outdoors, up to 1 000 V (17.1)
- Luminaires with high-intensity discharge lamps and ignitors — working voltage UR = US / 4,6, opening time warning (17.6.5, 17.7.1, 17.7.2)
- Luminaires with glass bulb lamps — retention of fragments, meshes and shields (17.7.3)
- Suspended luminaires — test of the hanger and the secondary suspension (17.7.4, 17.7.6)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 26.11.2026) | PKN card: PN-EN IEC 60598-2-17:2018-05 — English version (28-05-2018, 20 pages), KT 4 (lighting technology), implements EN IEC 60598-2-17:2018 [IDT] and IEC 60598-2-17:2017 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-17:2002; the card gives no withdrawal date. |
| Scope (17.1) | stage, television, film and photographic luminaires (with spot and floodlighting projectors), indoors and outdoors, supply voltage up to 1 000 V |
| Working voltage with ignitor (17.7.1) | UR = US / 4,6; above 1 000 V — opening only with a tool or an automatic switch on all poles |
| Lamp fragments (17.7.3) | "gravity" openings retain fragments > 3 mm; mesh up to 8 mm or labyrinth; in front of a glass shield — up to 12 mm; single lens — up to 25 mm; multi-lens objective — no mesh; impact 0,5 Nm (4.21.4 of Part 1) |
| Hanger — stirrup (17.7.4) | six times the weight of the luminaire for 1 h; no permanent deformation; non-combustible material (e.g. steel) |
| Secondary suspension (17.7.6) | luminaire hangs on it alone, raised by 300 mm and allowed to fall freely, 30 times; nothing may fall |
| Temperature marking (17.6.3, 17.6.6) | ta; highest exterior surface temperature where above 70 °C; housing temperature not above the marked value (17.13.2) |
| Wiring (17.11.1) | Class I and II: at least 0,75 mm² above 2 A up to 3 A, at least 1,5 mm² above 3 A |
| Order of tests (17.13.1, 17.14) | luminaires above IP20: tests 12.4–12.7 of Part 1 after 9.2 but before 9.3 |
Standard
- Standard number
- PN-EN IEC 60598-2-17:2018-05 (English version, published 28-05-2018; implements EN IEC 60598-2-17:2018 and IEC 60598-2-17:2017 [IDT])
- Title (PL)
- Oprawy oświetleniowe — Część 2-17: Wymagania szczegółowe — Oprawy do oświetlenia scenicznego oraz do studiów telewizyjnych i filmowych (zewnętrznych i wewnętrznych)
- Title (EN)
- Luminaires — Part 2-17: Particular requirements — Luminaires for stage lighting, television and film studios (outdoor and indoor)
Step-by-step procedure
-
Classification and marking
Classification according to Section 2 of Part 1 (17.5); marking of the "top", angles and mounting, warnings, ta, distances from flammable materials, surface temperature above 70 °C, instructions (17.6).
-
Electrical construction
Protection when inserting the lamp, working voltage UR = US / 4,6 with ignitors, device or marking for high-intensity discharge lamps (17.7.1, 17.7.2).
-
Lamp fragments
Inspection of openings, meshes and shields; impact 0,5 Nm according to 4.21.4 of Part 1 (17.7.3).
-
Hanger and secondary suspension
Six times the weight of the luminaire for 1 h (17.7.4); 30 free falls from a height of 300 mm on the secondary suspension (17.7.6); accessories do not fall out in any position (17.7.5).
-
Wiring, terminals and thermal tests
Cross-sections according to 17.11.1, non-interchangeability of connectors (17.11.2), no type b terminals (17.10); luminaires above IP20 — tests 12.4–12.7 between 9.2 and 9.3; housing temperature not above the marked value (17.13, 17.14).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Weights equal to six times the weight of the luminaire (17.7.4) | Loading time 1 h | — |
| Drop test set-up on the secondary suspension (17.7.6) | Raising by 300 mm and free fall, 30 times | — |
| Impact test apparatus according to 4.21.4 of Part 1 (17.7.3) | Impact energy 0,5 Nm | — |
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN IEC 60598-2-17:2018-05 (English version, published 28-05-2018; implements EN IEC 60598-2-17:2018 and IEC 60598-2-17:2017 [IDT]) — “Luminaires — Part 2-17: Particular requirements — Luminaires for stage lighting, television and film studios (outdoor and indoor)”.
How does this method work?
The luminaire is tested according to IEC 60598-1 in the order of the Part 1 sections, with the additional requirements of Part 2-17: the hanger is loaded with six times the weight of the luminaire for 1 h, the secondary suspension is checked by 30 free falls of the luminaire from a height of 300 mm, shields in front of a glass bulb lamp — by an impact of 0,5 Nm according to 4.21.
What is the measuring range and accuracy?
STATUS (as of 26.11.2026): PKN card: PN-EN IEC 60598-2-17:2018-05 — English version (28-05-2018, 20 pages), KT 4 (lighting technology), implements EN IEC 60598-2-17:2018 [IDT] and IEC 60598-2-17:2017 [IDT], directive 2014/35/EU, replaces PN-EN 60598-2-17:2002; the card gives no withdrawal date.; Scope (17.1): stage, television, film and photographic luminaires (with spot and floodlighting projectors), indoors and outdoors, supply voltage up to 1 000 V; Working voltage with ignitor (17.7.1): UR = US / 4,6; above 1 000 V — opening only with a tool or an automatic switch on all poles; Lamp fragments (17.7.3): "gravity" openings retain fragments > 3 mm; mesh up to 8 mm or labyrinth; in front of a glass shield — up to 12 mm; single lens — up to 25 mm; multi-lens objective — no mesh; impact 0,5 Nm (4.21.4 of Part 1).
How long does the test take?
The times given for the individual stages add up to approximately 1 h. The procedure comprises 5 steps.
What equipment is required?
Weights equal to six times the weight of the luminaire (17.7.4), Drop test set-up on the secondary suspension (17.7.6), Impact test apparatus according to 4.21.4 of Part 1 (17.7.3).
Where is this test used?
Stage and studio luminaires (television, film, photography), including spot and floodlighting projectors, indoors and outdoors, up to 1 000 V (17.1); Luminaires with high-intensity discharge lamps and ignitors — working voltage UR = US / 4,6, opening time warning (17.6.5, 17.7.1, 17.7.2); Luminaires with glass bulb lamps — retention of fragments, meshes and shields (17.7.3); Suspended luminaires — test of the hanger and the secondary suspension (17.7.4, 17.7.6).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN IEC 60598-2-17.