🔌 Electrical resistance of rubber and plastics hoses and hose assemblies — conductive, antistatic and non-conductive hoses, 500 V d.c. instrument, band electrodes, electrical continuity and discontinuity between metal end fittings, resistance through the hose wall; PN-EN ISO 8031

Materials and NDT PN-EN ISO 8031

In short

Electrical test methods for rubber and plastics hoses, tubing and hose assemblies: the resistance of conductive, antistatic and non-conductive hoses and the electrical continuity or discontinuity between metal end fittings. The test is performed according to PN-EN ISO 8031:2021-01 (English version; implements EN ISO 8031:2020 and ISO 8031:2020 [IDT]); STATUS (as of 21.11.2026): PKN card: PN-EN ISO 8031:2021-01 “Węże i przewody z gumy i z tworzyw sztucznych -- Oznaczanie rezystancji elektrycznej i przewodności” — English version, published 14-01-2021, 30 pages, KT 186, implements EN ISO 8031:2020 [IDT] and ISO 8031:2020 [IDT], replaces PN-EN ISO 8031:2010 (English version); the card gives no withdrawal date. At the publisher ISO 8031:2020: “Published”, stage 90.92 “International Standard to be revised” (iTeh card). The procedure comprises 4 steps (about 16 h in total); it is used for: Rubber and plastics hoses, tubing and hose assemblies — conductive, antistatic and non-conductive (clause 1), Hoses with conducting lining, with conducting cover or made of conducting compounds throughout (4.1), Laboratory tests and field, routine and acceptance tests at the manufacturer's plant (4.2.2.1, 4.5, 4.6.1).

At a glance

  • Standard: PN-EN ISO 8031:2021-01 (English version; implements EN ISO 8031:2020 and ISO 8031:2020 [IDT])
  • Category: Materials and NDT
  • Procedure steps: 4
  • Total time of stages: 16 h
  • STATUS (as of 21.11.2026): PKN card: PN-EN ISO 8031:2021-01 “Węże i przewody z gumy i z tworzyw sztucznych -- Oznaczanie rezystancji elektrycznej i przewodności” — English version, published 14-01-2021, 30 pages, KT 186, implements EN ISO 8031:2020 [IDT] and ISO 8031:2020 [IDT], replaces PN-EN ISO 8031:2010 (English version); the card gives no withdrawal date. At the publisher ISO 8031:2020: “Published”, stage 90.92 “International Standard to be revised” (iTeh card).
  • Voltage and accuracy (4.2.1.1): 500 V d.c. (open-circuit voltage), ±10 %; in dispute at least 40 V on the test piece
  • Power in the test piece (4.2.1.1): not more than 3 W (U² / R) — protection against heating effects

Overview

WHAT THE STANDARD COVERS. According to clause 1 of ISO 8031:2020 the standard specifies electrical test methods for rubber and plastics hoses, tubing and hose assemblies to determine the resistance of conductive, antistatic and non-conductive hoses and the electrical continuity or discontinuity between metal end fittings. All test methods described for rubber hoses can also be applied to plastics hoses. Normative references: ISO 2878 (rubber, vulcanized or thermoplastic — antistatic and conductive products — determination of electrical resistance) and ISO 8330 (vocabulary).

ACCORDING TO THE TEXT OF ISO 8031:2020 (fourth edition, 2020-06; publisher's sample: foreword, introduction, clauses 1–4.6.2.2). The standard was prepared by ISO/TC 45, subcommittee SC 1 (rubber and plastics hoses and hose assemblies). The fourth edition replaces the third (ISO 8031:2009) as a minor revision with updated normative references. According to the introduction the standard includes a continuity test between end fittings without measuring the resistance, methods for determining the resistance through the hose wall (required in some product standards for hoses used in explosive atmospheres) and Annex A — an amended version of Annex A of ISO 8330:2007. The product standard specifies which method is used to verify the required property.

INSTRUMENTS (4.2.1). The resistance of conductive, antistatic and non-conductive hoses is preferably measured with an insulation resistance tester with a nominal open-circuit voltage of 500 V d.c. (or an instrument known to give comparable results), accurate to ±10 %, with not more than 3 W dissipated in the specimen (square of the open-circuit voltage divided by the measured resistance); in cases of dispute the voltage applied to the test piece shall be not less than 40 V, unless this conflicts with the 3 W limit. Continuity between end fittings or through continuous wires — ohmmeter accurate to ±10 %; continuity without measuring resistance, where permitted by the product standard — 4,5 V battery with a 4 V (0,3 A) test lamp; resistance through the hose wall — ohmmeter with a capacity of 10¹² Ω at 500 V d.c., accurate to ±5 %.

ELECTRODES (4.2.2). In the laboratory, electrodes are formed as bands (25 +2/−1) mm wide around the circumference — of conductive silver lacquer, colloidal graphite or a conductive liquid (800 parts by mass of anhydrous poly(ethylene glycol) of relative molecular mass 600, 200 parts of water, 1 part of wetting agent, 10 parts of potassium chloride); the surface resistance of the dried lacquer or graphite film shall not exceed 100 Ω. For hoses of less than 50 mm bore a brass plug coated with conductive liquid and pushed 25 mm into the hose is preferable. For through-wall measurement an outer electrode of copper sheet 25 mm wide is used, with an inner electrode — a brass plug (bore up to 50 mm) or an adjustable copper band (bore over 50 mm), and for corrugated linings or linings less flexible than rubber (e.g. PTFE) — a conducting foam plug wetted with conductive liquid.

PREPARATION AND MEASUREMENT (4.3–4.6). Surfaces are cleaned if necessary with fuller's earth and water, rinsed with distilled water and dried; organic materials that make the rubber swell shall not be used, and the surfaces shall not be buffed. A long hose is uncoiled and laid straight on polyethylene or another insulating material. Conditioning: at least 16 h at (23 ± 2) °C and (50 ± 5) % relative humidity or at (27 ± 2) °C and (65 ± 5) %; for very long lengths, in field tests and acceptance tests by agreement — prevailing conditions with relative humidity not greater than 70 %. Hose with conducting lining — electrodes on the inside surface at each end, the edge of the band coincident with the end of the hose; hose with conducting cover — electrodes on the outside surface at each end. The resistance is read (5 ± 1) s after application of the voltage. In field tests and acceptance tests at the factory, clean copper or brass contacts of at least 100 mm² can be used. In the laboratory a conducting cover is tested on five lengths about 300 mm long, with electrodes (100 ± 1) mm apart (nearest edges), on insulating blocks providing a resistance greater than 10¹¹ Ω to the supporting surface.

WHAT WE DO NOT GIVE HERE. The sample ends at 4.6.2.2. We do not reproduce the methods for hoses with conducting compounds throughout (4.7), hose assemblies with metal end fittings (4.8), through-wall resistance measurement (4.9), continuity and discontinuity between end fittings (clauses 5–6), measurement of the resistance of a lining or cover in contact with the end fitting (clause 7), the test report requirements (clause 8) or the recommended resistance limits of Annex A, because they are not in the text we read; nor do we know the wording of a Polish version — PKN published PN-EN ISO 8031:2021-01 in English.

STATUS (as of 21.11.2026). PKN card: PN-EN ISO 8031:2021-01 “Węże i przewody z gumy i z tworzyw sztucznych -- Oznaczanie rezystancji elektrycznej i przewodności” — English version, published 14-01-2021, 30 pages, KT 186 (rubber and rubber products), implements EN ISO 8031:2020 [IDT] and ISO 8031:2020 [IDT], replaces PN-EN ISO 8031:2010 (English version); the card gives no withdrawal date. At the publisher ISO 8031:2020 has the status “Published”, stage 90.92 “International Standard to be revised” (iTeh catalogue card) — the standard is in force and ISO has announced its revision.

Method principle

A d.c. voltage (usually 500 V) is applied between electrodes placed on the hose — on the lining, on the cover or on both sides of the wall, depending on the hose construction — and the resistance is read after (5 ± 1) s; continuity between metal end fittings is checked with an ohmmeter or with a battery and test lamp where the product standard does not require a resistance value.

Applications

Key parameters

ParameterValue
STATUS (as of 21.11.2026)PKN card: PN-EN ISO 8031:2021-01 “Węże i przewody z gumy i z tworzyw sztucznych -- Oznaczanie rezystancji elektrycznej i przewodności” — English version, published 14-01-2021, 30 pages, KT 186, implements EN ISO 8031:2020 [IDT] and ISO 8031:2020 [IDT], replaces PN-EN ISO 8031:2010 (English version); the card gives no withdrawal date. At the publisher ISO 8031:2020: “Published”, stage 90.92 “International Standard to be revised” (iTeh card).
Voltage and accuracy (4.2.1.1)500 V d.c. (open-circuit voltage), ±10 %; in dispute at least 40 V on the test piece
Power in the test piece (4.2.1.1)not more than 3 W (U² / R) — protection against heating effects
Through-wall resistance (4.2.1.4)ohmmeter with a capacity of 10¹² Ω, 500 V d.c., accuracy ±5 %
Continuity without measurement (4.2.1.3)4,5 V battery with a 4 V (0,3 A) test lamp
Electrodes (4.2.2.1)bands (25 +2/−1) mm: silver lacquer, colloidal graphite or conductive liquid; lacquer or graphite film ≤ 100 Ω
Reading (4.5, 4.6)(5 ± 1) s after application of the voltage
Conditioning (4.4)at least 16 h: (23 ± 2) °C and (50 ± 5) % relative humidity or (27 ± 2) °C and (65 ± 5) %; prevailing conditions with humidity ≤ 70 % by agreement
Laboratory cover test pieces (4.6.2)five lengths of about 300 mm, electrode spacing (100 ± 1) mm, insulation from the support > 10¹¹ Ω

Standard

Standard number
PN-EN ISO 8031:2021-01 (English version; implements EN ISO 8031:2020 and ISO 8031:2020 [IDT])
Title (PL)
Węże i przewody z gumy i z tworzyw sztucznych — Oznaczanie rezystancji elektrycznej i przewodności
Title (EN)
Rubber and plastics hoses and hose assemblies — Determination of electrical resistance and conductivity

Step-by-step procedure

  1. Preparation

    Cleaning of the surfaces without organic solvents and without buffing; hose laid straight on insulating material, without leakage paths along the hose (4.3).

  2. Conditioning

    At least 16 h at (23 ± 2) °C and (50 ± 5) % or (27 ± 2) °C and (65 ± 5) % relative humidity (4.4).

    ⏱ Time: at least 16 h

  3. Electrodes

    Bands (25 +2/−1) mm on the lining (inside, at each end) or on the cover (outside, at each end); metal contacts on the electrodes (4.2.2, 4.5, 4.6.1).

  4. Measurement

    Application of the voltage and reading of the resistance after (5 ± 1) s; laboratory cover test pieces — five lengths of about 300 mm, electrodes (100 ± 1) mm apart, on blocks > 10¹¹ Ω (4.5, 4.6.2).

Required equipment and apparatus

EquipmentExampleIndicative price
Insulation resistance tester (4.2.1.1)Nominal open-circuit voltage 500 V d.c., accuracy ±10 %; according to ISO 2878—
Ohmmeter (4.2.1.2, 4.2.1.4)For continuity — accuracy ±10 %; for through-wall measurement — capacity 10¹² Ω at 500 V, accuracy ±5 %—
Laboratory electrodes (4.2.2.1)Bands (25 +2/−1) mm wide of silver lacquer, colloidal graphite or conductive liquid; metal contacts not larger than the electrodes; brass plug for bores < 50 mm—
Special electrodes (4.2.2.2)Outer copper sheet band 25 mm; inner electrode — brass plug or adjustable copper band; conducting foam plug or strip for corrugated linings and covers—
Insulating blocks (4.3, 4.6.2.2)Polyethylene or other insulating material; resistance to the support greater than 10¹¹ Ω—

Reagents, media and consumables

ReagentCASDetails
Conductive liquid (4.2.2.1)—800 parts by mass of anhydrous poly(ethylene glycol) of relative molecular mass 600, 200 parts of water, 1 part of wetting agent, 10 parts of potassium chloride — unless otherwise specified
Fuller's earth (4.3)—Magnesium aluminium silicate with water for cleaning the surfaces, followed by washing with distilled water

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-EN ISO 8031:2021-01 (English version; implements EN ISO 8031:2020 and ISO 8031:2020 [IDT]) — “Rubber and plastics hoses and hose assemblies — Determination of electrical resistance and conductivity”.

How does this method work?

A d.c.

What is the measuring range and accuracy?

STATUS (as of 21.11.2026): PKN card: PN-EN ISO 8031:2021-01 “Węże i przewody z gumy i z tworzyw sztucznych -- Oznaczanie rezystancji elektrycznej i przewodności” — English version, published 14-01-2021, 30 pages, KT 186, implements EN ISO 8031:2020 [IDT] and ISO 8031:2020 [IDT], replaces PN-EN ISO 8031:2010 (English version); the card gives no withdrawal date. At the publisher ISO 8031:2020: “Published”, stage 90.92 “International Standard to be revised” (iTeh card).; Voltage and accuracy (4.2.1.1): 500 V d.c. (open-circuit voltage), ±10 %; in dispute at least 40 V on the test piece; Power in the test piece (4.2.1.1): not more than 3 W (U² / R) — protection against heating effects; Through-wall resistance (4.2.1.4): ohmmeter with a capacity of 10¹² Ω, 500 V d.c., accuracy ±5 %.

How long does the test take?

The times given for the individual stages add up to approximately 16 h. The procedure comprises 4 steps.

What equipment is required?

Insulation resistance tester (4.2.1.1), Ohmmeter (4.2.1.2, 4.2.1.4), Laboratory electrodes (4.2.2.1), Special electrodes (4.2.2.2), Insulating blocks (4.3, 4.6.2.2).

Where is this test used?

Rubber and plastics hoses, tubing and hose assemblies — conductive, antistatic and non-conductive (clause 1); Hoses with conducting lining, with conducting cover or made of conducting compounds throughout (4.1); Laboratory tests and field, routine and acceptance tests at the manufacturer's plant (4.2.2.1, 4.5, 4.6.1); Resistance through the wall of hoses for explosive atmospheres, where required by the product standard (4.2.1.4, 4.9).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN ISO 8031.

🔍 Find a laboratory performing this test