🌿 Volatile oil content of spices and herbs — hydrodistillation of an aqueous suspension, collection of the oil in a graduated tube with a measured volume of xylene, reading of the organic phase, result in millilitres per 100 g of dry matter; PN-EN ISO 6571
In short
The volatile oil content of spices and herbs is determined by steam distillation of an aqueous suspension of the product and collection of the distillate in a graduated tube containing a measured volume of xylene, which fixes the oil. The test is performed according to PN-EN ISO 6571:2009 (English version; implements EN ISO 6571:2009 and ISO 6571:2008 [IDT]) with amendment PN-EN ISO 6571:2009/A1:2018-02 (implements EN ISO 6571:2009/A1:2017 and ISO 6571:2008/Amd 1:2017 [IDT]); STATUS (as of 21.11.2026): PKN cards: PN-EN ISO 6571:2009 “Przyprawy i zioła -- Oznaczanie zawartości olejku eterycznego (metoda hydrodestylacji)” — English version, published 06-08-2009, 12 pages, KT 110, implements EN ISO 6571:2009 [IDT] and ISO 6571:2008 [IDT], replaces PN-ISO 6571:2001 (Polish version); amendment PN-EN ISO 6571:2009/A1:2018-02 (English version, published 01-02-2018, implements ISO 6571:2008/Amd 1:2017 [IDT]); the cards give no withdrawal date. At the publisher ISO 6571:2008: “Published”, stage 90.93 “International Standard confirmed”; Amd 1:2017: “Published” (iTeh cards). The procedure comprises 5 steps (about 30 min in total); it is used for: Spices, condiments and herbs (clause 1), Result related to dry matter — with the moisture content determined by the entrainment method of ISO 939 (8.4.3, clause 9), Testing according to the parameters of the requirements standard for the given spice or, in its absence, according to Annex A (clause 8).
At a glance
- Standard: PN-EN ISO 6571:2009 (English version; implements EN ISO 6571:2009 and ISO 6571:2008 [IDT]) with amendment PN-EN ISO 6571:2009/A1:2018-02 (implements EN ISO 6571:2009/A1:2017 and ISO 6571:2008/Amd 1:2017 [IDT])
- Category: Food chemistry
- Procedure steps: 5
- Total time of stages: 30 min
- STATUS (as of 21.11.2026): PKN cards: PN-EN ISO 6571:2009 “Przyprawy i zioła -- Oznaczanie zawartości olejku eterycznego (metoda hydrodestylacji)” — English version, published 06-08-2009, 12 pages, KT 110, implements EN ISO 6571:2009 [IDT] and ISO 6571:2008 [IDT], replaces PN-ISO 6571:2001 (Polish version); amendment PN-EN ISO 6571:2009/A1:2018-02 (English version, published 01-02-2018, implements ISO 6571:2008/Amd 1:2017 [IDT]); the cards give no withdrawal date. At the publisher ISO 6571:2008: “Published”, stage 90.93 “International Standard confirmed”; Amd 1:2017: “Published” (iTeh cards).
- Unit of result (3.1, clause 9): ml of volatile oil per 100 g of dry product
- Formula (clause 9): wVO = 100 × (V1 − V0) / m × 100 / (100 − wH2O)
Overview
WHAT THE STANDARD COVERS. According to clause 1 of ISO 6571:2008 the standard specifies a method for the determination of the volatile oil content of spices, condiments and herbs. The volatile oil content (3.1) is all the substances entrained by steam under the conditions of the standard, expressed in millilitres per 100 g of dry product. Normative references: ISO 939 (moisture content, entrainment method) and ISO 2825 (preparation of a ground sample). Sampling is not part of the method; a recommended method is given in ISO 948.
ACCORDING TO THE TEXT OF ISO 6571:2008 (second edition, 2008-05-01; publisher's sample: foreword, clauses 1–9 and the beginning of clause 10) AND OF AMENDMENT ISO 6571:2008/Amd 1:2017 (full text of the amendment). The standard was prepared by ISO/TC 34, subcommittee SC 7 (spices, culinary herbs and condiments); the second edition replaced the first (ISO 6571:1984). Amendment 1 requires the graduated tube with divisions of 0,05 ml (JL) to have a volume of at least 3,5 ml, and supplements the footnote on the apparatus: it corresponds to the type described in the European Pharmacopoeia (V 5.89), 2.8.12, with modifications according to 6.1.2 d).
APPARATUS (clause 6). Distillation apparatus of strong glass with a low coefficient of thermal expansion, connected by ground glass joints: round-bottom flask of 500 ml or 1 000 ml depending on the product, condenser system with a vertical tube (AC), a bent tube (CDE), a vertical bulb condenser (FG) and an assembly with a side-arm (K) with stopper (K′), a pear-shaped enlargement (J), a tube graduated in divisions of 0,05 ml (JL), a spherical enlargement (L), a three-way tap (M) and an inclined tube (O) with a safety tube (N), topped if necessary by a steam trap. In addition: filter paper 110 mm in diameter, 1 ml pipette, heating device (heating without overheating the flask, temperature regulation recommended), anti-bumping granules or glass beads, 500 ml measuring cylinder and analytical balance. Reagents: xylene; for cleaning — acetone (fatty residues) and liquid detergent or a mixture of sulfuric acid with saturated potassium dichromate solution (the standard warns against contact of this solution with skin and mucous membranes).
PROCEDURE (clause 8). The test parameters (mass of test portion, volume of water, flask size, distillation time, fineness) are intended to be given in the International Standard specifying requirements for each spice, and in the meantime they are given in Annex A. The condenser system is cleaned by leaving it upside down filled with cleaning solution overnight and rinsing it carefully with water. If the test portion has to be ground, it is crushed just before the test according to ISO 2825 so that its temperature does not rise. First the volume of xylene is determined: the specified volume of water is poured into the flask, the graduated tube, spherical enlargement and inclined tube are filled with water, 1 ml of xylene is added by pipette, distillation is carried out for about 30 min at 2 ml/min to 3 ml/min, the upper level of the xylene is set to zero with the three-way tap, the system is cooled for at least 10 min and the volume of xylene (V0) is read. Then the filter paper with the test portion (weighed to the nearest 0,01 g) is placed in the flask, distillation is continued for the time given in Annex A (the time is recorded in the test report) and, after 10 min of cooling, the total volume of the organic phase (V1) is read. The moisture content is determined according to ISO 939.
RESULT (clause 9). wVO = 100 × (V1 − V0) / m × 100 / (100 − wH2O), in millilitres per 100 g of dry product, where V0 is the volume of xylene and V1 the volume of oil with xylene, in millilitres, m the mass of the test portion in grams, wH2O the moisture content as a percentage by mass.
WHAT WE DO NOT GIVE HERE. We do not reproduce the parameters for individual spices from Annex A (test portion mass, volume of water, flask, distillation time), the precision data of Annex B or the test report requirements, because the sample ends at the beginning of clause 10; nor do we know the wording of a Polish version — PKN published PN-EN ISO 6571:2009 and amendment A1 in English.
STATUS (as of 21.11.2026). PKN cards: PN-EN ISO 6571:2009 “Przyprawy i zioła -- Oznaczanie zawartości olejku eterycznego (metoda hydrodestylacji)” — English version, published 06-08-2009, 12 pages, KT 110 (herbal raw materials and products), implements EN ISO 6571:2009 [IDT] and ISO 6571:2008 [IDT], replaces PN-ISO 6571:2001 (Polish version); PN-EN ISO 6571:2009/A1:2018-02 — English version, published 01-02-2018, implements EN ISO 6571:2009/A1:2017 [IDT] and ISO 6571:2008/Amd 1:2017 [IDT]; the cards give no withdrawal date. At the publisher ISO 6571:2008 has the status “Published”, stage 90.93 “International Standard confirmed”, and amendment Amd 1:2017 — “Published” (iTeh catalogue cards).
Method principle
An aqueous suspension of spices or herbs is distilled with steam; the distillate is collected in a graduated tube containing a measured volume of xylene, which fixes the volatile oil. After the phases have separated, the total volume of the organic phase is read and, after deduction of the volume of xylene, the oil content is calculated in millilitres per 100 g of dry product.
Applications
- Spices, condiments and herbs (clause 1)
- Result related to dry matter — with the moisture content determined by the entrainment method of ISO 939 (8.4.3, clause 9)
- Testing according to the parameters of the requirements standard for the given spice or, in its absence, according to Annex A (clause 8)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 21.11.2026) | PKN cards: PN-EN ISO 6571:2009 “Przyprawy i zioła -- Oznaczanie zawartości olejku eterycznego (metoda hydrodestylacji)” — English version, published 06-08-2009, 12 pages, KT 110, implements EN ISO 6571:2009 [IDT] and ISO 6571:2008 [IDT], replaces PN-ISO 6571:2001 (Polish version); amendment PN-EN ISO 6571:2009/A1:2018-02 (English version, published 01-02-2018, implements ISO 6571:2008/Amd 1:2017 [IDT]); the cards give no withdrawal date. At the publisher ISO 6571:2008: “Published”, stage 90.93 “International Standard confirmed”; Amd 1:2017: “Published” (iTeh cards). |
| Unit of result (3.1, clause 9) | ml of volatile oil per 100 g of dry product |
| Formula (clause 9) | wVO = 100 × (V1 − V0) / m × 100 / (100 − wH2O) |
| Xylene (8.4.1) | 1 ml added by pipette; its volume V0 is determined after about 30 min of distillation of water alone |
| Distillation rate (8.4.1, 8.4.2) | 2 ml/min or 3 ml/min unless otherwise specified |
| Graduated tube JL (6.1.2 d), Amendment 1) | divisions of 0,05 ml, volume at least 3,5 ml |
| Cooling before reading (8.4.1, 8.4.2) | at least 10 min (xylene) and 10 min (organic phase) |
Standard
- Standard number
- PN-EN ISO 6571:2009 (English version; implements EN ISO 6571:2009 and ISO 6571:2008 [IDT]) with amendment PN-EN ISO 6571:2009/A1:2018-02 (implements EN ISO 6571:2009/A1:2017 and ISO 6571:2008/Amd 1:2017 [IDT])
- Title (PL)
- Przyprawy i zioła — Oznaczanie zawartości olejku eterycznego (metoda hydrodestylacji)
- Title (EN)
- Spices, condiments and herbs — Determination of volatile oil content (hydrodistillation method)
Step-by-step procedure
-
Cleaning of the apparatus
Condenser system upside down and filled with cleaning solution overnight, then careful rinsing with water (8.1).
-
Sample and test portion
Grinding (if required) just before the test according to ISO 2825 without a rise in temperature; test portion weighed on the filter paper to the nearest 0,01 g in the quantity given in Annex A (8.2, 8.3).
-
Volume of xylene
Water in the flask, tube and enlargement filled with water, 1 ml of xylene, distillation for about 30 min at 2–3 ml/min, setting the xylene to zero, cooling for at least 10 min, reading V0 (8.4.1).
-
Hydrodistillation of the test portion
Filter paper with the test portion in the flask, distillation for the time given in Annex A (time recorded for the report), after 10 min of cooling reading V1 of the organic phase (8.4.2).
-
Moisture and result
Moisture according to ISO 939; calculation of wVO in ml per 100 g of dry product (8.4.3, clause 9).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Distillation apparatus (6.1, Amendment 1) | Glass with a low coefficient of thermal expansion, ground glass joints; type described in the European Pharmacopoeia (V 5.89), 2.8.12, with modifications according to 6.1.2 d) | — |
| Round-bottom flask (6.1.1) | Capacity 500 ml or 1 000 ml, depending on the product (Annex A) | — |
| Condenser system with graduated tube (6.1.2) | Bulb condenser, tube graduated in divisions of 0,05 ml with a volume of at least 3,5 ml, three-way tap, inclined tube with safety tube; steam trap (6.1.3) | — |
| Auxiliary equipment (6.2–6.7) | Filter paper 110 mm in diameter, 1 ml pipette, heating device with regulation, anti-bumping granules or glass beads, 500 ml measuring cylinder, analytical balance | — |
Reagents, media and consumables
| Reagent | CAS | Details |
|---|---|---|
| Xylene (5.1) | — | To fix the volatile oil in the graduated tube; reagents of recognized analytical grade, distilled water or water of equivalent purity |
| Cleaning solutions (5.2) | — | Acetone (fatty residues); liquid detergent or a mixture of one volume of concentrated sulfuric acid with one volume of saturated potassium dichromate solution, passed through a fritted glass filter |
Health and safety (OHS)
- The standard warns against contact of the sulfuric acid and potassium dichromate mixture (cleaning solution) with skin and mucous membranes (5.2.2)
- Heating should avoid overheating of the flask; a temperature-regulating device is recommended (6.4)
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN ISO 6571:2009 (English version; implements EN ISO 6571:2009 and ISO 6571:2008 [IDT]) with amendment PN-EN ISO 6571:2009/A1:2018-02 (implements EN ISO 6571:2009/A1:2017 and ISO 6571:2008/Amd 1:2017 [IDT]) — “Spices, condiments and herbs — Determination of volatile oil content (hydrodistillation method)”.
How does this method work?
An aqueous suspension of spices or herbs is distilled with steam; the distillate is collected in a graduated tube containing a measured volume of xylene, which fixes the volatile oil. After the phases have separated, the total volume of the organic phase is read and, after deduction of the volume of xylene, the oil content is calculated in millilitres per 100 g of dry product.
What is the measuring range and accuracy?
STATUS (as of 21.11.2026): PKN cards: PN-EN ISO 6571:2009 “Przyprawy i zioła -- Oznaczanie zawartości olejku eterycznego (metoda hydrodestylacji)” — English version, published 06-08-2009, 12 pages, KT 110, implements EN ISO 6571:2009 [IDT] and ISO 6571:2008 [IDT], replaces PN-ISO 6571:2001 (Polish version); amendment PN-EN ISO 6571:2009/A1:2018-02 (English version, published 01-02-2018, implements ISO 6571:2008/Amd 1:2017 [IDT]); the cards give no withdrawal date. At the publisher ISO 6571:2008: “Published”, stage 90.93 “International Standard confirmed”; Amd 1:2017: “Published” (iTeh cards).; Unit of result (3.1, clause 9): ml of volatile oil per 100 g of dry product; Formula (clause 9): wVO = 100 × (V1 − V0) / m × 100 / (100 − wH2O); Xylene (8.4.1): 1 ml added by pipette; its volume V0 is determined after about 30 min of distillation of water alone.
How long does the test take?
The times given for the individual stages add up to approximately 30 min. The procedure comprises 5 steps.
What equipment is required?
Distillation apparatus (6.1, Amendment 1), Round-bottom flask (6.1.1), Condenser system with graduated tube (6.1.2), Auxiliary equipment (6.2–6.7).
Where is this test used?
Spices, condiments and herbs (clause 1); Result related to dry matter — with the moisture content determined by the entrainment method of ISO 939 (8.4.3, clause 9); Testing according to the parameters of the requirements standard for the given spice or, in its absence, according to Annex A (clause 8).
What safety precautions apply?
The standard warns against contact of the sulfuric acid and potassium dichromate mixture (cleaning solution) with skin and mucous membranes (5.2.2); Heating should avoid overheating of the flask; a temperature-regulating device is recommended (6.4).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN ISO 6571.