⚡ Immunity of electrical and electronic equipment to the ring wave on low-voltage power, control and signal lines — rise time 0.5 µs, oscillation 100 kHz, test levels from 0.25 to 4 kV or level X; PN-EN 61000-4-12

Electronics and EMC PN-EN 61000-4-12

In short

Basic EMC publication describing the immunity test of electrical and electronic equipment under operational conditions to ring waves occurring in low-voltage power, control and signal lines supplied by public and non-public networks. The test is performed according to PN-EN 61000-4-12:2017-12 (English version, published 11-12-2017; implements EN 61000-4-12:2017 and IEC 61000-4-12:2017 [IDT]); STATUS (as of 27.11.2026): PKN card: PN-EN 61000-4-12:2017-12 — English version (11-12-2017, 56 pages), KT 104, implements EN 61000-4-12:2017 [IDT] and IEC 61000-4-12:2017 [IDT], replaces PN-EN 61000-4-12:2009; the card gives no withdrawal date. The procedure comprises 4 steps; it is used for: Power, control and signal ports of equipment supplied from public and non-public low-voltage networks (Clause 1), Immunity tests required by product and product family standards that refer to IEC 61000-4-12 (IEC Guide 107), Equipment with semiconductor power input circuitry — phase angle dependence and follow current (4.2.2).

At a glance

  • Standard: PN-EN 61000-4-12:2017-12 (English version, published 11-12-2017; implements EN 61000-4-12:2017 and IEC 61000-4-12:2017 [IDT])
  • Category: Electronics and EMC
  • Procedure steps: 4
  • STATUS (as of 27.11.2026): PKN card: PN-EN 61000-4-12:2017-12 — English version (11-12-2017, 56 pages), KT 104, implements EN 61000-4-12:2017 [IDT] and IEC 61000-4-12:2017 [IDT], replaces PN-EN 61000-4-12:2009; the card gives no withdrawal date.
  • Test waveform (4.1): rise time T1 = 0.5 µs, oscillation period T = 10 µs (100 kHz); at Pk2 in Figure 1: "110 % to 40 %" (Pk1 = 100 %); only Pk1 is specified for the short-circuit current
  • Parameters of the w(t) formula (4.1): A = 1; K = 1.81; n = 1.83; t1 = 0.507 µs; R = 2

Overview

WHAT THE STANDARD COVERS. According to Clause 1 of IEC 61000-4-12:2017 the standard relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to ring waves occurring in low-voltage power, control and signal lines supplied by public and non-public networks. Its object is a common reference for evaluating immunity; it defines test voltage and current waveforms, a range of test levels, test equipment, test setups and test procedures. It is a basic EMC publication according to IEC Guide 107 — product committees decide whether the test is applied and set the test levels and performance criteria.

ACCORDING TO THE TEXT OF IEC 61000-4-12:2017 (third edition; the publisher's sample covers the contents, foreword, introduction, Clauses 1–5 and the beginning of 6.1.1). The standard was prepared by subcommittee IEC SC 77B of IEC TC 77. The third edition replaces the second edition of 2006; changes according to the foreword: mathematical modelling of the waveform, new Annex B (selection of generators and test levels), new Annex C (explanatory notes), new Annex D (measurement uncertainty), a coupling/decoupling network (CDN) for high-speed lines and a calibration procedure for CDNs. According to the introduction, edition 1 of 1995 covered ring waves and damped oscillatory waves; since edition 2 the latter are in IEC 61000-4-18.

PHENOMENON (4.1). The ring wave is an oscillatory transient induced in low-voltage cables by the switching of electrical networks and reactive loads, faults and insulation breakdown of power supply circuits or lightning; it is representative of residential and industrial environments. The impulses have sharp fronts in the order of 10 ns to a fraction of a µs and a duration from 10 µs to 100 µs. A ring wave with a 0.5 µs rise time and a 100 kHz oscillation frequency has been determined to be typical. The ideal waveform formula w(t) for the period T = 10 µs has the parameters A = 1, K = 1.81, n = 1.83, t1 = 0.507 µs; the ratio R of successive peaks Pk2/Pk3, Pk3/Pk4 was chosen equal to 2, and n and t1 were adjusted to obtain T1 = 0.5 µs. Only Pk1 is specified for the short-circuit current waveform; in Figure 1 the range "110 % to 40 %" is given at peak Pk2 (on the scale on which Pk1 = 100 %). The 1.2/50 µs impulse of IEC 61000-4-5 may be considered complementary.

PARAMETERS (4.2). The repetition rate is related to the frequency of the primary phenomenon — typically from once per second down to once per year; it may be increased to reduce the test duration, selected according to the characteristics of the protection device. Failures on AC power supplies can depend on the phase angle — when a protection element operates, follow current may flow; this concerns especially semiconductors in the power input circuitry.

TEST LEVELS (Clause 5, Table 1). The test level is the open-circuit voltage of the first peak (Pk1): level 1 — 0.25 kV line-to-line and 0.5 kV line-to-ground, level 2 — 0.5 and 1 kV, level 3 — 1 and 2 kV, level 4 — 2 and 4 kV, level X — special, specified by product committees or the equipment specification. For symmetrical interconnection lines the test can be applied to multiple lines simultaneously with respect to ground. The test is applied at all levels of Table 1 up to and including the specified level (8.3); levels are selected according to the installation conditions (installation classes — Annex C, selection — Annex B). The generator shall be capable of operating under short-circuit conditions (6.1.1).

WHAT WE DO NOT GIVE HERE. The sample ends at 6.1.1 — we do not reproduce the generator impedance, characteristics and calibration of the generator and CDNs, test setups (Clause 7), execution of the test (8.3), evaluation of results (9) or the content of the test report (10).

STATUS (as of 27.11.2026). PKN card: PN-EN 61000-4-12:2017-12 "Kompatybilność elektromagnetyczna (EMC) -- Część 4-12: Metody badań i pomiarów -- Badanie odporności na tłumione przebiegi sinusoidalne" — English version (published 11-12-2017, 56 pages), KT 104 (electromagnetic compatibility), implements EN 61000-4-12:2017 [IDT] and IEC 61000-4-12:2017 [IDT], replaces PN-EN 61000-4-12:2009 (Polish version), ICS 33.100.20; the card gives no withdrawal date and no additional elements.

Method principle

A ring wave with a 0.5 µs rise time and a 10 µs period (100 kHz) is applied through a coupling/decoupling network to a power, control or signal port of the equipment under test (EUT), line-to-line and line-to-ground, successively at all levels of Table 1 up to and including the specified level, and the operation of the equipment is observed.

Applications

Key parameters

ParameterValue
STATUS (as of 27.11.2026)PKN card: PN-EN 61000-4-12:2017-12 — English version (11-12-2017, 56 pages), KT 104, implements EN 61000-4-12:2017 [IDT] and IEC 61000-4-12:2017 [IDT], replaces PN-EN 61000-4-12:2009; the card gives no withdrawal date.
Test waveform (4.1)rise time T1 = 0.5 µs, oscillation period T = 10 µs (100 kHz); at Pk2 in Figure 1: "110 % to 40 %" (Pk1 = 100 %); only Pk1 is specified for the short-circuit current
Parameters of the w(t) formula (4.1)A = 1; K = 1.81; n = 1.83; t1 = 0.507 µs; R = 2
Test level (Clause 5)open-circuit voltage of the first peak Pk1
Levels line-to-line / line-to-ground (Table 1)1: 0.25 / 0.5 kV; 2: 0.5 / 1 kV; 3: 1 / 2 kV; 4: 2 / 4 kV; X: special
Sequence of levels (Clause 5)all levels of Table 1 up to and including the specified one (8.3)
Repetition rate (4.2.1)in the phenomenon: from once per second down to once per year; in the test it may be increased according to the characteristics of the protection device

Standard

Standard number
PN-EN 61000-4-12:2017-12 (English version, published 11-12-2017; implements EN 61000-4-12:2017 and IEC 61000-4-12:2017 [IDT])
Title (PL)
Kompatybilność elektromagnetyczna (EMC) — Część 4-12: Metody badań i pomiarów — Badanie odporności na tłumione przebiegi sinusoidalne
Title (EN)
Electromagnetic compatibility (EMC) — Part 4-12: Testing and measurement techniques — Ring wave immunity test

Step-by-step procedure

  1. Selection of levels

    Test level from the product standard or equipment specification; selection according to the installation class (Annexes B and C) and Table 1.

  2. Preparation of equipment

    Generator and CDNs according to Clause 6, verification of the test instrumentation before the test (7.2).

  3. Application of the waveform

    Successively all levels of Table 1 up to and including the specified one; line-to-line and line-to-ground, for symmetrical lines also "lines to ground" (Clause 5).

  4. Evaluation and report

    Evaluation of the operation of the equipment according to the criteria set by the product committee or specification (Clauses 9 and 10).

Required equipment and apparatus

EquipmentExampleIndicative price
Ring wave generator (6.1)Output capable of operating under short-circuit conditions—
Coupling/decoupling networks (CDN) for AC/DC power ports and interconnection lines (6.2)According to the contents: CDNs for power ports rated up to 63 A per line and for interconnection lines, with calibration (6.3)—

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-EN 61000-4-12:2017-12 (English version, published 11-12-2017; implements EN 61000-4-12:2017 and IEC 61000-4-12:2017 [IDT]) — “Electromagnetic compatibility (EMC) — Part 4-12: Testing and measurement techniques — Ring wave immunity test”.

How does this method work?

A ring wave with a 0.5 µs rise time and a 10 µs period (100 kHz) is applied through a coupling/decoupling network to a power, control or signal port of the equipment under test (EUT), line-to-line and line-to-ground, successively at all levels of Table 1 up to and including the specified level, and the operation of the equipment is observed.

What is the measuring range and accuracy?

STATUS (as of 27.11.2026): PKN card: PN-EN 61000-4-12:2017-12 — English version (11-12-2017, 56 pages), KT 104, implements EN 61000-4-12:2017 [IDT] and IEC 61000-4-12:2017 [IDT], replaces PN-EN 61000-4-12:2009; the card gives no withdrawal date.; Test waveform (4.1): rise time T1 = 0.5 µs, oscillation period T = 10 µs (100 kHz); at Pk2 in Figure 1: "110 % to 40 %" (Pk1 = 100 %); only Pk1 is specified for the short-circuit current; Parameters of the w(t) formula (4.1): A = 1; K = 1.81; n = 1.83; t1 = 0.507 µs; R = 2; Test level (Clause 5): open-circuit voltage of the first peak Pk1.

How long does the test take?

The procedure comprises 4 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.

What equipment is required?

Ring wave generator (6.1), Coupling/decoupling networks (CDN) for AC/DC power ports and interconnection lines (6.2).

Where is this test used?

Power, control and signal ports of equipment supplied from public and non-public low-voltage networks (Clause 1); Immunity tests required by product and product family standards that refer to IEC 61000-4-12 (IEC Guide 107); Equipment with semiconductor power input circuitry — phase angle dependence and follow current (4.2.2).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 61000-4-12.

🔍 Find a laboratory performing this test