🌿 2-Methoxypropyl acetate in workplace air — activated charcoal, carbon disulphide, gas chromatography; lowest determinable concentration per the standard 5 mg/m³; NDS 100 mg/m³, NDSCh 200 mg/m³; PN-Z-04305:2003
In short
Determination of 2-methoxypropyl acetate in workplace air according to the Polish national standard from 2003: adsorption of the vapour on activated charcoal, desorption with carbon disulphide and gas chromatography. The test is performed according to PN-Z-04305:2003 (Polish version); STATUS (as of 18.11.2026): current, no withdrawal note. The procedure comprises 4 steps; it is used for: Measurement of 2-methoxypropyl acetate [70657-70-4] in workplace air — assessment against the NDS of 100 mg/m³ and the NDSCh of 200 mg/m³ (Journal of Laws 2026 item 447, item 436).
At a glance
- Standard: PN-Z-04305:2003 (Polish version)
- Category: Environment
- Procedure steps: 4
- STATUS (as of 18.11.2026): current, no withdrawal note
- Edition (from the PKN card): PN-Z-04305:2003, Polish version; published 28-10-2003, 7 pages, KT 159, ICS 13.040.30
- Lowest determinable concentration (from the card): 5 mg/m³ — 1/20 of the NDS
Overview
STATUS (as of 18.11.2026). The PKN card of PN-Z-04305:2003 (Polish version) has no withdrawal note — the standard is CURRENT: published 28-10-2003, 7 pages, KT 159 Chemical and Dust Hazards in the Working Environment, ICS 13.040.30.
WHAT THIS STANDARD COVERS. Scope from the PKN catalogue card, in full (our translation): “A method is given consisting in the adsorption of 2-methoxypropyl vapour on activated charcoal, desorption of the compound with carbon disulphide and analysis of the solution obtained by gas chromatography. The lowest concentration of 2-methoxypropyl that can be determined by this method is 5 mg/m3” (wording as on the card — the scope lacks the word “acetate”, which is in the title of the standard). The card gives no detector, air volume or flow rate.
LIMIT VALUES AND THE RULE ON METHODS. List of NDS values (Journal of Laws 2026 item 447), item 436 “Octan 2-metoksypropylu” [70657-70-4]: NDS 100 mg/m³, NDSCh 200 mg/m³, without the “skin” notation; the transitional provisions of the amending acts do not mention this substance. The lowest determinable concentration according to the card (5 mg/m³) is 1/20 of the NDS. The neighbouring item 435 “Octan 2-metoksy-1-metyloetylu” [108-65-6] is a different substance: NDS 260 mg/m³, NDSCh 520 mg/m³, “skin”. § 16 of the regulation on tests and measurements (consolidated text Journal of Laws 2025 item 949): tests and measurements are performed by methods from Polish Standards and, where there are none, by methods recommended and validated by the laboratories referred to in § 15; this standard is a current Polish Standard, the regulation does not name it.
SECOND SOURCE ON THE PROCEDURE. We found no CIOP-PIB procedure or NIOSH method for 2-methoxypropyl acetate [70657-70-4] — the search returned only procedures for other glycol ether acetates (2-methoxyethyl acetate and 2-ethoxyethyl acetate). The description is therefore based solely on the card of the standard and on the regulations.
WHAT WE DO NOT GIVE HERE. We did not have the text of PN-Z-04305:2003 — PKN sells it (7 pages). We do not give the detector, the air volume or flow rate, the amount of charcoal, the volume of carbon disulphide, the column, the chromatograph conditions or the calculations.
Method principle
2-Methoxypropyl acetate vapour is adsorbed on activated charcoal, desorbed with carbon disulphide and the solution obtained is analysed by gas chromatography (PKN card); lowest determinable concentration per the card — 5 mg/m³. The result is compared with the NDS of 100 mg/m³ and the NDSCh of 200 mg/m³ (Journal of Laws 2026 item 447, item 436).
Applications
- Measurement of 2-methoxypropyl acetate [70657-70-4] in workplace air — assessment against the NDS of 100 mg/m³ and the NDSCh of 200 mg/m³ (Journal of Laws 2026 item 447, item 436)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 18.11.2026) | current, no withdrawal note |
| Edition (from the PKN card) | PN-Z-04305:2003, Polish version; published 28-10-2003, 7 pages, KT 159, ICS 13.040.30 |
| Lowest determinable concentration (from the card) | 5 mg/m³ — 1/20 of the NDS |
| Limit values against which the result is assessed | NDS 100 mg/m³, NDSCh 200 mg/m³, no “skin” notation — Journal of Laws 2026 item 447, item 436 |
| Isomer with different values | 2-methoxy-1-methylethyl acetate [108-65-6]: NDS 260 mg/m³, NDSCh 520 mg/m³, “skin” — item 435 |
Standard
- Standard number
- PN-Z-04305:2003 (Polish version)
- Title (PL)
- Ochrona czystości powietrza — Oznaczanie octanu 2-metoksypropylu na stanowiskach pracy metodą chromatografii gazowej
- Title (EN)
- Air purity protection — Determination of 2-methoxypropyl acetate at workplaces by gas chromatography
Step-by-step procedure
-
Status of the document
PKN card: PN-Z-04305:2003 current (as of 18.11.2026).
-
Sampling
Adsorption of 2-methoxypropyl acetate vapour on activated charcoal (PKN card).
-
Desorption and analysis
Desorption with carbon disulphide and gas chromatography of the solution obtained; lowest determinable concentration 5 mg/m³ (PKN card).
-
Result and assessment
2-Methoxypropyl acetate concentration in mg/m³; comparison with the NDS of 100 mg/m³ and the NDSCh of 200 mg/m³ (Journal of Laws 2026 item 447, item 436).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Gas chromatograph | Analysis of the carbon disulphide solution (PKN card); the detector and conditions of the standard are not known to us | — |
| Activated charcoal tubes and suction pump | Adsorption of the vapour (PKN card); volume and flow rate of the standard are not known to us | — |
Reagents, media and consumables
| Reagent | CAS | Details |
|---|---|---|
| Activated charcoal | — | Sorbent for 2-methoxypropyl acetate vapour (PKN card) |
| Carbon disulphide | 75-15-0 | For desorption (PKN card); the volume of the standard is not known to us |
Health and safety (OHS)
- 2-Methoxypropyl acetate [70657-70-4] and 2-methoxy-1-methylethyl acetate [108-65-6] have separate items with different values in the NDS list — the identity of the substance is confirmed by the CAS number
- TECHNICAL NOTE: assigning the result to the wrong isomer changes the assessment — NDS 100 mg/m³ (item 436) versus 260 mg/m³ with the “skin” notation (item 435)
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-Z-04305:2003 (Polish version) — “Air purity protection — Determination of 2-methoxypropyl acetate at workplaces by gas chromatography”.
How does this method work?
2-Methoxypropyl acetate vapour is adsorbed on activated charcoal, desorbed with carbon disulphide and the solution obtained is analysed by gas chromatography (PKN card); lowest determinable concentration per the card — 5 mg/m³. The result is compared with the NDS of 100 mg/m³ and the NDSCh of 200 mg/m³ (Journal of Laws 2026 item 447, item 436).
What is the measuring range and accuracy?
STATUS (as of 18.11.2026): current, no withdrawal note; Edition (from the PKN card): PN-Z-04305:2003, Polish version; published 28-10-2003, 7 pages, KT 159, ICS 13.040.30; Lowest determinable concentration (from the card): 5 mg/m³ — 1/20 of the NDS; Limit values against which the result is assessed: NDS 100 mg/m³, NDSCh 200 mg/m³, no “skin” notation — Journal of Laws 2026 item 447, item 436.
How long does the test take?
The procedure comprises 4 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.
What equipment is required?
Gas chromatograph, Activated charcoal tubes and suction pump.
Where is this test used?
Measurement of 2-methoxypropyl acetate [70657-70-4] in workplace air — assessment against the NDS of 100 mg/m³ and the NDSCh of 200 mg/m³ (Journal of Laws 2026 item 447, item 436).
What safety precautions apply?
2-Methoxypropyl acetate [70657-70-4] and 2-methoxy-1-methylethyl acetate [108-65-6] have separate items with different values in the NDS list — the identity of the substance is confirmed by the CAS number; TECHNICAL NOTE: assigning the result to the wrong isomer changes the assessment — NDS 100 mg/m³ (item 436) versus 260 mg/m³ with the “skin” notation (item 435).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-Z-04305.