💡 Mains socket-outlet mounted nightlights: particular requirements — cover test with test probe 19 at a force of 30 N at operating temperature, pull on the cover of 90 N for 60 s, additional torque on the socket-outlet not greater than 0,25 Nm, 3 kV 1,2/50 µs surge for electroluminescent panels; PN-EN 60598-2-12
In short
Particular requirements for nightlights plugged directly into a mains socket-outlet and supplied with alternating voltage up to 250 V at 50 or 60 Hz. The test is performed according to PN-EN 60598-2-12:2013-12 (English version 17-12-2013 and Polish version 02-09-2015; implements EN 60598-2-12:2013 and IEC 60598-2-12:2013 [IDT]); STATUS (as of 25.11.2026): PKN cards: PN-EN 60598-2-12:2013-12 — English version (17-12-2013, 20 pages) and Polish version (02-09-2015, 14 pages), KT 4 (lighting technology), implements EN 60598-2-12:2013 [IDT] and IEC 60598-2-12:2013 [IDT], Directive 2014/35/EU, replaces PN-EN 60598-2-12:2007 (Polish version); the cards give no withdrawal date. The procedure comprises 5 steps (about 11 min in total); it is used for: Nightlights plugged directly into a mains socket-outlet, alternating voltage up to 250 V at 50/60 Hz (12.1, 12.4.1), Nightlights with an electroluminescent panel — surge test (12.7.11), Nightlights with an incorporated socket-outlet — test of 4.14.6 of Part 1 with a plug and 0,75 mm² cable (12.7.12).
At a glance
- Standard: PN-EN 60598-2-12:2013-12 (English version 17-12-2013 and Polish version 02-09-2015; implements EN 60598-2-12:2013 and IEC 60598-2-12:2013 [IDT])
- Category: Electronics and EMC
- Procedure steps: 5
- Total time of stages: 11 min
- STATUS (as of 25.11.2026): PKN cards: PN-EN 60598-2-12:2013-12 — English version (17-12-2013, 20 pages) and Polish version (02-09-2015, 14 pages), KT 4 (lighting technology), implements EN 60598-2-12:2013 [IDT] and IEC 60598-2-12:2013 [IDT], Directive 2014/35/EU, replaces PN-EN 60598-2-12:2007 (Polish version); the cards give no withdrawal date.
- Scope (12.1): mains socket-outlet mounted nightlights, alternating voltage up to 250 V, 50/60 Hz; not luminaires for surveillance lighting
- Classification (12.5): always ordinary and suitable for direct mounting on normally flammable surfaces
Overview
WHAT THE STANDARD COVERS. According to 12.1 of IEC 60598-2-12:2013 the standard specifies requirements for mains socket-outlet mounted nightlights for use with electric light sources on supply voltages not exceeding 250 V a.c. 50/60 Hz; it does not cover luminaires for surveillance lighting. A nightlight is, according to 12.4.1, a luminaire intended to provide a source of low-level illuminance in areas not normally illuminated at night; a note to the definition explains that such nightlights are normally installed in locations accessible to young children, which is why requirements beyond those for other socket-outlet mounted luminaires apply. The standard is read together with IEC 60598-1; the tests of the Part 1 sections are carried out in the order listed in Part 2-12 (12.3). Multiple-function products (e.g. a nightlight with a socket adaptor) are assessed against the standards for each function.
ACCORDING TO THE TEXT OF IEC 60598-2-12:2013 (edition 2.0, 2013-04; the publisher's sample covers the foreword and clauses 12.1–12.14.2 a)). The standard was prepared by subcommittee IEC SC 34D (luminaires) of IEC TC 34. The second edition replaces the first edition of 2006; according to the foreword it is a technical revision to harmonize the thermal tests with the relevant parts of 10.12.1 of IEC 60598-2-10. The standard was established on the basis of the seventh edition (2008) of IEC 60598-1. Normative references: IEC/TR 60083 (plugs and socket-outlets standardized in IEC member countries), IEC 60598-1, IEC 60884-1 (plugs and socket-outlets), IEC 60950-1, IEC 61032:1997 (test probes), IEC 60227 (PVC-insulated cables), IEC 61000-4-5 (surge immunity test).
CLASSIFICATION (12.5). Nightlights are classified according to Section 2 of Part 1, except that they are always classified as ordinary and suitable for direct mounting on normally flammable surfaces; according to the note, they therefore need no warning notice.
CONSTRUCTION (12.7). The plug portion shall comply with the appropriate national standard sheets of IEC/TR 60083 (check: inspection, measurement, gauges) and with the other constructional requirements of IEC 60884-1 or the national standard (12.7.1, 12.7.2). The mechanical strength tests of 4.13.1 of Part 1 are applied with the forces of Table 4.3 of Part 1 for portable luminaires for children (12.7.3). Resistance of the cover to penetration (12.7.4): during the test of 12.4.1 of Part 1 the temperatures of the places where failure is possible are measured; immediately afterwards the sample is placed in a heating cabinet (as in 13.2.1 of Part 1) so that the highest measured temperature is reached, and at that temperature test probe 19 of IEC 61032:1997 is applied to the accessible surface with a force of 30 N (tolerance +0/−5 N); it shall not be possible to touch live parts and, in Class II nightlights, parts with basic insulation. The light source cannot be changed while the nightlight is connected to the supply; the cover cannot be removed while the nightlight is inserted in a socket-outlet; cover fixing screws are captive or — where the user does not replace the light source — of a special type requiring a special tool (12.7.5).
COVER FIXING (12.7.6). Immediately after the test of 12.4.1 of Part 1, at the temperature reached in that test (heating cabinet as in 13.2.1 of Part 1): a) each cover fixing screw is pulled with 90 N (±2 N) for 60 s (+5/−0 s); after the test the screw shall be serviceable and the cover in place so that test probe 19 applied with a force of 5 N (tolerance +0/−0,5 N) cannot touch internal live parts; b) for covers fixed by means other than screws (e.g. rivets, clips, adhesive, ultrasonic welding) all plug pins are clamped together in a jig and pulled with 90 N (±2 N) for 60 s ± 5 s while the plug cover is suspended by a suitable means; afterwards test probe 19 applied with a force of 5 N (tolerance +0/−1 N) cannot touch internal live parts.
LOAD ON THE SOCKET-OUTLET (12.7.7). The nightlight is inserted into a socket-outlet complying with the standard sheet of IEC/TR 60083; the socket-outlet is pivoted about a horizontal axis 8 mm behind its engagement face and parallel with it, with its centre equidistant from the pin centres. The additional torque needed to keep the engagement face in the vertical plane shall not exceed 0,25 Nm.
OTHER CONSTRUCTIONAL REQUIREMENTS. The cover shall not be shaped or decorated so that children are likely to treat the nightlight as a toy (12.7.8). Where the corresponding plug has a fuse, the nightlight also has a suitable fuse (12.7.9). Series resistors in nightlights with neon lamps shall not be of the “composition” or “carbon film” type (12.7.10). A nightlight with an electroluminescent panel shall withstand a voltage surge (12.7.11): the sample is placed on a pine wood surface covered with white tissue paper, covered with a single layer of bleached cotton cheesecloth according to IEC 60950-1 and connected to rated voltage (earth terminal, if any, to the neutral, switches “ON”), then 10 surges of 3 kV 1,2/50 µs are applied at intervals of about 60 s with random polarity; generator — 1,2/50 combination wave generator according to IEC 61000-4-5. A risk of fire or electric shock exists if the cheesecloth or tissue paper glows, chars or ignites, or if the insulation between live parts of the panel and accessible metal parts breaks down during the test or in the electric strength test of Section 10 of Part 1; it is acceptable that the sample no longer works after the test. For nightlights with a socket-outlet, the test of 4.14.6 of Part 1 is made with a plug and 1 m of 0,75 mm² circular flexible cable according to IEC 60227 (designation 60227 IEC 52) (12.7.12).
WIRING, PROTECTION AGAINST ELECTRIC SHOCK, DISTANCES (12.8–12.13). The nightlight has integral plug-pins for connection to the supply; a nightlight with a socket-outlet complies with the safety requirements of IEC 60884-1; apart from the socket-outlet it shall have no means for connecting external wiring or other devices (12.8). With the nightlight inserted in a socket-outlet, the lampholder and other internal live parts shall not be accessible — check by inspection and with test probe 19 applied in all directions with a force of 5 N (tolerance +0/−1 N) (12.10). Clause 9.3 of Section 9 and Sections 7, 10 and 11 of Part 1 apply; metal parts other than the plug-pins that are exposed on the engagement face and in contact with live parts shall be recessed at least 3 mm below that face (12.13).
THERMAL TESTS (12.14). During the tests of Section 12 of Part 1 the temperature of the plug-pins shall not exceed the value of the relevant national standard referenced in IEC/TR 60083, and the temperature of the socket-outlet engagement face 65 °C (12.14.1); for accessible parts of the nightlight the sample gives a) 55 °C for metal parts (12.14.2).
WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. The probe and pull tests on the cover are carried out at the temperature reached during the test of 12.4.1 of Part 1 (sample in a heating cabinet), not at ambient temperature; the probe forces differ between clauses (30 N in 12.7.4, 5 N in 12.7.6 and 12.10) and have tolerances downwards only.
WHAT WE DO NOT GIVE HERE. The rest of 12.14.2 (values for parts other than metal) and clauses 12.15–12.17 (resistance to heat, fire and tracking, screw terminals and screwless terminals) — the sample breaks off at 12.14.2 a); we know them only from the titles in the table of contents.
STATUS (as of 25.11.2026). PKN cards: PN-EN 60598-2-12:2013-12 “Oprawy oświetleniowe -- Część 2-12: Wymagania szczegółowe -- Lampki nocne do montowania w gniazdach sieciowych” — English version (published 17-12-2013, 20 pages) and Polish version (published 02-09-2015, 14 pages), KT 4 (lighting technology), implements EN 60598-2-12:2013 [IDT] and IEC 60598-2-12:2013 [IDT], Directive 2014/35/EU, replaces PN-EN 60598-2-12:2007 (Polish version); the cards give no withdrawal date and no additional elements.
Method principle
The nightlight is tested according to IEC 60598-1 in the order of the Part 1 sections, with the additional requirements of Part 2-12: test probe 19 is used to check the cover at operating temperature (30 N) and after pulling the cover or the pins with 90 N for 60 s (5 N), the additional torque imposed on the socket-outlet is measured (not more than 0,25 Nm), and nightlights with an electroluminescent panel are subjected to 10 surges of 3 kV 1,2/50 µs on a tissue-paper base and under cotton cheesecloth.
Applications
- Nightlights plugged directly into a mains socket-outlet, alternating voltage up to 250 V at 50/60 Hz (12.1, 12.4.1)
- Nightlights with an electroluminescent panel — surge test (12.7.11)
- Nightlights with an incorporated socket-outlet — test of 4.14.6 of Part 1 with a plug and 0,75 mm² cable (12.7.12)
- Checking the load on the socket-outlet and the durability of the cover fixing (12.7.6, 12.7.7)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 25.11.2026) | PKN cards: PN-EN 60598-2-12:2013-12 — English version (17-12-2013, 20 pages) and Polish version (02-09-2015, 14 pages), KT 4 (lighting technology), implements EN 60598-2-12:2013 [IDT] and IEC 60598-2-12:2013 [IDT], Directive 2014/35/EU, replaces PN-EN 60598-2-12:2007 (Polish version); the cards give no withdrawal date. |
| Scope (12.1) | mains socket-outlet mounted nightlights, alternating voltage up to 250 V, 50/60 Hz; not luminaires for surveillance lighting |
| Classification (12.5) | always ordinary and suitable for direct mounting on normally flammable surfaces |
| Cover — probe 19 (12.7.4) | force 30 N (+0/−5 N) at the highest temperature measured in the test of 12.4.1 of Part 1 |
| Pull (12.7.6) | 90 N (±2 N) for 60 s; then probe 19 with a force of 5 N (−0,5 N for screws, −1 N for other fixings) |
| Load on the socket-outlet (12.7.7) | pivot axis 8 mm behind the engagement face; additional torque ≤ 0,25 Nm |
| Surge (12.7.11) | electroluminescent panels: 10 surges of 3 kV 1,2/50 µs at about 60 s intervals, random polarity, generator according to IEC 61000-4-5 |
| Distances (12.13) | metal parts on the engagement face in contact with live parts recessed at least 3 mm |
| Temperatures (12.14) | socket-outlet engagement face ≤ 65 °C; accessible metal parts of the nightlight ≤ 55 °C; plug-pins — according to the national standard from IEC/TR 60083 |
Standard
- Standard number
- PN-EN 60598-2-12:2013-12 (English version 17-12-2013 and Polish version 02-09-2015; implements EN 60598-2-12:2013 and IEC 60598-2-12:2013 [IDT])
- Title (PL)
- Oprawy oświetleniowe — Część 2-12: Wymagania szczegółowe — Lampki nocne do montowania w gniazdach sieciowych
- Title (EN)
- Luminaires — Part 2-12: Particular requirements — Mains socket-outlet mounted nightlights
Step-by-step procedure
-
Tests according to IEC 60598-1
Tests of the Part 1 sections in the order listed in Part 2-12 (12.3); classification as an ordinary luminaire for mounting on normally flammable surfaces (12.5).
-
Plug portion and load on the socket-outlet
Compliance with the national standard sheet of IEC/TR 60083 and with IEC 60884-1 (12.7.1, 12.7.2); additional torque on the socket-outlet ≤ 0,25 Nm (12.7.7).
-
Cover at operating temperature
Temperature measurement in the test of 12.4.1 of Part 1, heating cabinet, probe 19 with a force of 30 N (12.7.4); pull on the screws or pins of 90 N for 60 s and check with probe 19 at 5 N (12.7.6).
-
Surge test
Nightlights with an electroluminescent panel: 10 surges of 3 kV 1,2/50 µs at about 60 s intervals; assessment of cheesecloth, tissue paper and insulation (12.7.11).
-
Thermal tests
Section 12 of Part 1 with the limits of 12.14: socket-outlet engagement face ≤ 65 °C, accessible metal parts ≤ 55 °C.
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Test probe 19 according to IEC 61032:1997 (12.7.4, 12.7.6, 12.10) | Applied with a force of 30 N or 5 N depending on the test | — |
| Heating cabinet (12.7.4, 12.7.6) | As in 13.2.1 of Part 1 — keeps the temperature reached in the test of 12.4.1 of Part 1 | — |
| Socket-outlet according to an IEC/TR 60083 sheet, pivoted about a horizontal axis (12.7.7) | Axis 8 mm behind the engagement face; measurement of the additional torque | — |
| 1,2/50 combination wave generator according to IEC 61000-4-5 (12.7.11) | 3 kV surges | — |
| Pine wood surface, tissue paper and bleached cotton cheesecloth according to IEC 60950-1 (12.7.11) | Indicator of fire risk in the surge test | — |
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN 60598-2-12:2013-12 (English version 17-12-2013 and Polish version 02-09-2015; implements EN 60598-2-12:2013 and IEC 60598-2-12:2013 [IDT]) — “Luminaires — Part 2-12: Particular requirements — Mains socket-outlet mounted nightlights”.
How does this method work?
The nightlight is tested according to IEC 60598-1 in the order of the Part 1 sections, with the additional requirements of Part 2-12: test probe 19 is used to check the cover at operating temperature (30 N) and after pulling the cover or the pins with 90 N for 60 s (5 N), the additional torque imposed on the socket-outlet is measured (not more than 0,25 Nm), and nightlights with an electroluminescent panel are subjected to 10 surges of 3 kV 1,2/50 µs on a tissue-paper base and under cotton cheesecloth.
What is the measuring range and accuracy?
STATUS (as of 25.11.2026): PKN cards: PN-EN 60598-2-12:2013-12 — English version (17-12-2013, 20 pages) and Polish version (02-09-2015, 14 pages), KT 4 (lighting technology), implements EN 60598-2-12:2013 [IDT] and IEC 60598-2-12:2013 [IDT], Directive 2014/35/EU, replaces PN-EN 60598-2-12:2007 (Polish version); the cards give no withdrawal date.; Scope (12.1): mains socket-outlet mounted nightlights, alternating voltage up to 250 V, 50/60 Hz; not luminaires for surveillance lighting; Classification (12.5): always ordinary and suitable for direct mounting on normally flammable surfaces; Cover — probe 19 (12.7.4): force 30 N (+0/−5 N) at the highest temperature measured in the test of 12.4.1 of Part 1.
How long does the test take?
The times given for the individual stages add up to approximately 11 min. The procedure comprises 5 steps.
What equipment is required?
Test probe 19 according to IEC 61032:1997 (12.7.4, 12.7.6, 12.10), Heating cabinet (12.7.4, 12.7.6), Socket-outlet according to an IEC/TR 60083 sheet, pivoted about a horizontal axis (12.7.7), 1,2/50 combination wave generator according to IEC 61000-4-5 (12.7.11), Pine wood surface, tissue paper and bleached cotton cheesecloth according to IEC 60950-1 (12.7.11).
Where is this test used?
Nightlights plugged directly into a mains socket-outlet, alternating voltage up to 250 V at 50/60 Hz (12.1, 12.4.1); Nightlights with an electroluminescent panel — surge test (12.7.11); Nightlights with an incorporated socket-outlet — test of 4.14.6 of Part 1 with a plug and 0,75 mm² cable (12.7.12); Checking the load on the socket-outlet and the durability of the cover fixing (12.7.6, 12.7.7).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 60598-2-12.