📡 Electromagnetic compatibility — emission of disturbances from electrical and electronic equipment in industrial environments: generic standard, requirements for each port in the range 9 kHz – 400 GHz, EUT test arrangements, measurement uncertainty according to CISPR 16-4-2; PN-EN IEC 61000-6-4
In short
Requirements for the emission of electromagnetic disturbances from electrical and electronic equipment intended for use at industrial locations, indoors and outdoors. The test is performed according to PN-EN IEC 61000-6-4:2019-12 (English and Polish version; implements EN IEC 61000-6-4:2019 and IEC 61000-6-4:2018 [IDT]); Frequency range (clause 1): emission requirements from 9 kHz to 400 GHz; no measurements where no requirement is specified. The procedure comprises 4 steps; it is used for: Electrical and electronic equipment intended for use at industrial locations, indoors and outdoors, where no product or product-family EMC emission standard exists (clause 1), Conducted emission measurements on low voltage AC mains ports and wired network ports (clause 9, Tables 4 and 5), Radiated emission measurements through the enclosure port, including at a measurement distance other than the reference distance (clause 9, Table 3).
At a glance
- Standard: PN-EN IEC 61000-6-4:2019-12 (English and Polish version; implements EN IEC 61000-6-4:2019 and IEC 61000-6-4:2018 [IDT])
- Category: Electronics and EMC
- Procedure steps: 4
- STATUS (as of 20.11.2026): PKN cards: PN-EN IEC 61000-6-4:2019-12 “Kompatybilność elektromagnetyczna (EMC) -- Część 6-4: Normy ogólne -- Norma emisji w środowiskach przemysłowych” — English version (published 13-12-2019, 38 pages) and Polish version (published 28-03-2025, 34 pages), KT 104 Electromagnetic Compatibility, implements EN IEC 61000-6-4:2019 and IEC 61000-6-4:2018 [IDT], replaces PN-EN 61000-6-4:2008 and PN-EN 61000-6-4:2008/A1:2012 (Polish versions); the cards give no withdrawal date. Card of PN-EN 61000-6-4:2008/A1:2012: withdrawal date 13-12-2019, replaced by PN-EN IEC 61000-6-4:2019-12. At the publisher, IEC 61000-6-4:2018 has the status “Published” (iTeh catalogue card).
- Frequency range (clause 1): emission requirements from 9 kHz to 400 GHz; no measurements where no requirement is specified
- Industrial location (3.1.12): separate power network supplied from a high- or medium-voltage transformer, dedicated for the supply of the installation
Overview
WHAT THE STANDARD COVERS. According to clause 1 of IEC 61000-6-4:2018 the standard covers emission requirements for electrical and electronic equipment intended for use within the environment existing at industrial locations (definition 3.1.12), indoors and outdoors. It does not apply to equipment within the scope of IEC 61000-6-3. It covers emission requirements in the frequency range from 9 kHz to 400 GHz, selected to provide an adequate level of protection of radio reception; no measurements are performed at frequencies where no requirement is specified. Requirements are given for each port considered. The standard is used where no applicable product or product-family EMC emission standard is available. It does not cover safety considerations or disturbances generated in fault conditions of the equipment.
ACCORDING TO THE TEXT OF IEC 61000-6-4:2018 (edition 3.0; publisher's sample: foreword, introduction, clauses 1–9 up to the description of Table 2). The standard was prepared by CISPR subcommittee H (limits for the protection of radio services). Edition 3.0 replaces the second edition of 2006 and amendment 1:2010; technical changes: possible future requirements for DC ports, possible future polarity-specific limits for radiated emission in a fully anechoic room (FAR), definition of the average detector above 1 GHz and acceptance of peak-detector results for all measurements, and definition of the EUT test arrangements. An industrial location (3.1.12) is a location characterized by a separate power network, supplied from a high- or medium-voltage transformer, dedicated for the supply of the installation. Small equipment (3.1.11) fits, including its cables, in a cylindrical test volume of 1,2 m in diameter and 1,5 m above the ground plane.
CONDITIONS DURING TESTING (clause 4). The equipment under test (EUT) is tested in the operating mode producing the largest emission in the frequency band being measured, consistent with normal applications; the configuration is varied to achieve maximum emission. Equipment that is part of a system is tested with the minimum representative configuration of associated equipment, as in CISPR 11 or CISPR 32. Test arrangement according to Table 1: table-top only — table-top; floor-standing only — floor-standing; floor-standing or table-top — table-top; rack mounted — in a rack or table-top; other (e.g. wall mounted, ceiling mounted, handheld, body worn) — table-top in normal orientation. Filters and shielding required by the manufacturer's instructions shall be in place. Measurements are carried out at one single set of parameters within the temperature, humidity and pressure ranges specified for the product and at the rated supply voltage; configuration and mode of operation are recorded in the test report.
ASSESSMENT (clauses 6–9). Measurements are carried out only where the relevant port exists; a decision not to measure shall be justified in the test report. The instrumentation uncertainty is taken into account according to CISPR 16-4-2, and when the laboratory uncertainty exceeds U_cispr, the adjustment of the result is given in the test report. In a retest the originally chosen method is used. At transitional frequencies the lower limit applies; a limit varying over a frequency range changes linearly with the logarithm of the frequency; the test site shall be validated for the chosen measurement distance; at a distance other than the reference distance the limit is converted using: new limit = defined limit – 20 log (measurement distance / reference distance), in dB(µV/m). The description of measurements and instrumentation is given in the standards referred to in Tables 3–5 (including CISPR 16-2-1, CISPR 16-2-3, CISPR 11, CISPR 32).
WHAT WE DO NOT GIVE HERE. The sample ends at the announcement of Table 2 (highest frequency for radiated emission measurement depending on the highest internal frequency Fx). We do not reproduce the limits of Tables 3–5 (enclosure port, low voltage AC mains port, wired network port) or the proposed limits for the DC power port (Annex A), because they are not in the text we read.
STATUS (as of 20.11.2026). PKN cards: PN-EN IEC 61000-6-4:2019-12 “Kompatybilność elektromagnetyczna (EMC) -- Część 6-4: Normy ogólne -- Norma emisji w środowiskach przemysłowych” — English version (published 13-12-2019, 38 pages) and Polish version (published 28-03-2025, 34 pages), KT 104 Electromagnetic Compatibility, implements EN IEC 61000-6-4:2019 and IEC 61000-6-4:2018 [IDT], replaces PN-EN 61000-6-4:2008 and PN-EN 61000-6-4:2008/A1:2012 (Polish versions); the cards give no withdrawal date. Card of PN-EN 61000-6-4:2008/A1:2012: withdrawal date 13-12-2019, replaced by PN-EN IEC 61000-6-4:2019-12. At the publisher, IEC 61000-6-4:2018 has the status “Published” (iTeh catalogue card).
Method principle
Disturbance emission is measured port by port — conducted on the power and wired network ports, radiated through the enclosure port — in the operating mode and EUT configuration producing the largest emission, using the methods and instrumentation of the CISPR standards referred to in Tables 3–5, and compared with the limits taking into account the instrumentation uncertainty according to CISPR 16-4-2.
Applications
- Electrical and electronic equipment intended for use at industrial locations, indoors and outdoors, where no product or product-family EMC emission standard exists (clause 1)
- Conducted emission measurements on low voltage AC mains ports and wired network ports (clause 9, Tables 4 and 5)
- Radiated emission measurements through the enclosure port, including at a measurement distance other than the reference distance (clause 9, Table 3)
- Choice of test arrangement: table-top, floor-standing, rack mounted, wall or ceiling mounted (clause 4, Table 1)
Key parameters
| Parameter | Value |
|---|---|
| STATUS (as of 20.11.2026) | PKN cards: PN-EN IEC 61000-6-4:2019-12 “Kompatybilność elektromagnetyczna (EMC) -- Część 6-4: Normy ogólne -- Norma emisji w środowiskach przemysłowych” — English version (published 13-12-2019, 38 pages) and Polish version (published 28-03-2025, 34 pages), KT 104 Electromagnetic Compatibility, implements EN IEC 61000-6-4:2019 and IEC 61000-6-4:2018 [IDT], replaces PN-EN 61000-6-4:2008 and PN-EN 61000-6-4:2008/A1:2012 (Polish versions); the cards give no withdrawal date. Card of PN-EN 61000-6-4:2008/A1:2012: withdrawal date 13-12-2019, replaced by PN-EN IEC 61000-6-4:2019-12. At the publisher, IEC 61000-6-4:2018 has the status “Published” (iTeh catalogue card). |
| Frequency range (clause 1) | emission requirements from 9 kHz to 400 GHz; no measurements where no requirement is specified |
| Industrial location (3.1.12) | separate power network supplied from a high- or medium-voltage transformer, dedicated for the supply of the installation |
| Small equipment (3.1.11) | fits with its cables in a cylinder 1,2 m in diameter and 1,5 m above the ground plane |
| Detectors (clause 9) | where a table clause gives two detectors — measurement with both; peak-detector results may replace the others |
| Other measurement distance (clause 9) | new limit = defined limit – 20 log (measurement distance / reference distance), dB(µV/m), distance in metres |
| Uncertainty (clause 7) | according to CISPR 16-4-2; where the laboratory uncertainty exceeds U_cispr, adjustment of the result in the test report |
Standard
- Standard number
- PN-EN IEC 61000-6-4:2019-12 (English and Polish version; implements EN IEC 61000-6-4:2019 and IEC 61000-6-4:2018 [IDT])
- Title (PL)
- Kompatybilność elektromagnetyczna (EMC) — Część 6-4: Normy ogólne — Norma emisji w środowiskach przemysłowych
- Title (EN)
- Electromagnetic compatibility (EMC) — Part 6-4: Generic standards — Emission standard for industrial environments
Step-by-step procedure
-
Scope check
Check that no product or product-family EMC emission standard exists and identify the ports of the equipment; measurements only on existing ports (clauses 1, 6).
-
Configuration and arrangement
Operating mode and configuration producing the largest emission, minimum representative configuration of associated equipment, arrangement according to Table 1, filters and shielding from the manufacturer's instructions (clause 4).
-
Measurements
Conducted and radiated emission measurements using the methods of the standards referred to in Tables 3–5, in any order, one measurement distance per table clause (clause 9).
-
Assessment and report
Comparison with the limits taking into account the uncertainty according to CISPR 16-4-2; the report gives configuration, operating mode, environmental conditions and the justification of measurements not performed (clauses 4, 6, 7).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Radio disturbance measuring apparatus (clauses 2, 9) | Measuring apparatus (CISPR 16-1-1), coupling devices for conducted disturbance measurements, e.g. artificial mains network AMN and asymmetric artificial network AAN (CISPR 16-1-2), antennas and test sites for radiated disturbance measurements (CISPR 16-1-4) | — |
| Radiated emission test site (3.2, clause 9) | Open area test site (OATS), semi anechoic chamber (SAC) or fully anechoic room (FAR), validated for the chosen distance | — |
| TEM waveguide (clause 2) | Emission testing according to IEC 61000-4-20:2010 | — |
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN IEC 61000-6-4:2019-12 (English and Polish version; implements EN IEC 61000-6-4:2019 and IEC 61000-6-4:2018 [IDT]) — “Electromagnetic compatibility (EMC) — Part 6-4: Generic standards — Emission standard for industrial environments”.
How does this method work?
Disturbance emission is measured port by port — conducted on the power and wired network ports, radiated through the enclosure port — in the operating mode and EUT configuration producing the largest emission, using the methods and instrumentation of the CISPR standards referred to in Tables 3–5, and compared with the limits taking into account the instrumentation uncertainty according to CISPR 16-4-2.
What is the measuring range and accuracy?
STATUS (as of 20.11.2026): PKN cards: PN-EN IEC 61000-6-4:2019-12 “Kompatybilność elektromagnetyczna (EMC) -- Część 6-4: Normy ogólne -- Norma emisji w środowiskach przemysłowych” — English version (published 13-12-2019, 38 pages) and Polish version (published 28-03-2025, 34 pages), KT 104 Electromagnetic Compatibility, implements EN IEC 61000-6-4:2019 and IEC 61000-6-4:2018 [IDT], replaces PN-EN 61000-6-4:2008 and PN-EN 61000-6-4:2008/A1:2012 (Polish versions); the cards give no withdrawal date. Card of PN-EN 61000-6-4:2008/A1:2012: withdrawal date 13-12-2019, replaced by PN-EN IEC 61000-6-4:2019-12. At the publisher, IEC 61000-6-4:2018 has the status “Published” (iTeh catalogue card).; Frequency range (clause 1): emission requirements from 9 kHz to 400 GHz; no measurements where no requirement is specified; Industrial location (3.1.12): separate power network supplied from a high- or medium-voltage transformer, dedicated for the supply of the installation; Small equipment (3.1.11): fits with its cables in a cylinder 1,2 m in diameter and 1,5 m above the ground plane.
How long does the test take?
The procedure comprises 4 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.
What equipment is required?
Radio disturbance measuring apparatus (clauses 2, 9), Radiated emission test site (3.2, clause 9), TEM waveguide (clause 2).
Where is this test used?
Electrical and electronic equipment intended for use at industrial locations, indoors and outdoors, where no product or product-family EMC emission standard exists (clause 1); Conducted emission measurements on low voltage AC mains ports and wired network ports (clause 9, Tables 4 and 5); Radiated emission measurements through the enclosure port, including at a measurement distance other than the reference distance (clause 9, Table 3); Choice of test arrangement: table-top, floor-standing, rack mounted, wall or ceiling mounted (clause 4, Table 1).
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN IEC 61000-6-4.