💡 Lighting chains: particular requirements — Class II or III only, at least IP 44 outdoors, E5 lampholders up to 25 V, E10 up to 60 V (series) and 250 V (parallel), temporarily installed protected lighting (TPL) chains as rough service luminaires; PN-EN IEC 60598-2-20

Electronics and EMC PN-EN IEC 60598-2-20

In short

Particular requirements for lighting chains with light sources connected in series, in parallel or in series/parallel, for use indoors and outdoors on supply voltages up to 250 V. The test is performed according to PN-EN IEC 60598-2-20:2024-10 (English version, published 07-10-2024; implements EN IEC 60598-2-20:2024 and IEC 60598-2-20:2022 [IDT]) with amendment PN-EN IEC 60598-2-20:2024-10/A11:2024-11; STATUS (as of 26.11.2026): PKN card: PN-EN IEC 60598-2-20:2024-10 — English version (07-10-2024, 30 pages), KT 4 (lighting technology), implements EN IEC 60598-2-20:2024 [IDT] and IEC 60598-2-20:2022 [IDT], replaces PN-EN 60598-2-20:2015-07 and its corrigendum AC:2017-03; amendment A11:2024-11 (19-11-2024, 6 pages). PN-EN 60598-2-20:2015-07 — withdrawn 07-10-2024. The procedure comprises 4 steps; it is used for: Permanently installed lighting chains (e.g. lighting of ski tracks, promenades), permanently connected to the fixed wiring (20.3.4), Temporarily installed lighting chains, including Christmas tree and decorative chains (20.3.5), Temporarily installed protected lighting (TPL) chains for building sites — as rough service luminaires, plugs and socket-outlets according to IEC 60309-1 (20.3.6, 20.7.1, 20.7.4).

At a glance

  • Standard: PN-EN IEC 60598-2-20:2024-10 (English version, published 07-10-2024; implements EN IEC 60598-2-20:2024 and IEC 60598-2-20:2022 [IDT]) with amendment PN-EN IEC 60598-2-20:2024-10/A11:2024-11
  • Category: Electronics and EMC
  • Procedure steps: 4
  • STATUS (as of 26.11.2026): PKN card: PN-EN IEC 60598-2-20:2024-10 — English version (07-10-2024, 30 pages), KT 4 (lighting technology), implements EN IEC 60598-2-20:2024 [IDT] and IEC 60598-2-20:2022 [IDT], replaces PN-EN 60598-2-20:2015-07 and its corrigendum AC:2017-03; amendment A11:2024-11 (19-11-2024, 6 pages). PN-EN 60598-2-20:2015-07 — withdrawn 07-10-2024.
  • Scope (20.1): lighting chains, supply voltage up to 250 V, indoors and outdoors; permanently installed, temporarily installed and temporarily installed protected (TPL)
  • Classification (20.5): Class II or III only; outdoor chains — IP 44 or higher

Overview

WHAT THE STANDARD COVERS. According to 20.1 of IEC 60598-2-20:2022 the standard specifies requirements for lighting chains fitted with series, parallel or series/parallel connected light sources for use indoors or outdoors on supply voltages not exceeding 250 V. It covers permanently installed lighting chains, temporarily installed lighting chains and temporarily installed protected lighting (TPL) chains. Lighting chains with fixed or detachable attachments (e.g. ornamental) are also covered; combinations with rope lights (sealed lighting chains) — see IEC 60598-2-21. For lighting chains with non-standardized light sources (e.g. of the push-in type) the light sources are regarded as part of the chain and tested with it. According to the notes to the scope: a chain permanently fixed to a frame or a pre-lit Christmas tree — also the relevant clauses of IEC 60598-2-4; candlestick luminaires are tested according to IEC 60598-2-4.

ACCORDING TO THE TEXT OF IEC 60598-2-20:2022 (fifth edition; the publisher's sample covers the foreword, the introduction and clauses 20.1–20.7.8). The standard was prepared by subcommittee IEC SC 34D (luminaires) of IEC TC 34 (lighting). The fifth edition replaces the fourth edition of 2014; technical changes according to the foreword: a) provisions for TPL chains added, b) new terms and definitions added; according to the introduction, figures of the types of lighting chains were also added (Figure 1). The standard was established on the basis of the ninth edition (2020) of IEC 60598-1 and is used with the latest edition of that standard and its amendments. Normative references include: IEC 60227-5:2011 (PVC-insulated flexible cables), IEC 60238:2016 with AMD1:2017 and AMD2:2020 (Edison screw lampholders), IEC 60309-1 (plugs, socket-outlets and couplers for industrial purposes), IEC 60320 (appliance couplers), IEC 60529 (IP code), IEC 61184:2017 with AMD1:2019 (bayonet lampholders), IEC 61347-2-11 and IEC 61347-2-13 (electronic circuits and LED controlgear), IEC 61984:2008 (connectors).

TYPES OF LIGHTING CHAINS (20.3). A permanently installed lighting chain is supported by the supply cable or attached at the lampholder and permanently connected to the fixed wiring (example: lighting of ski tracks or promenades; in some countries — "festoon"). A temporarily installed lighting chain is supported by the supply cable and temporarily connected to the fixed wiring (example: a Christmas tree lighting chain; in some countries — decorative). A TPL chain has each lampholder attached to the building or structure, the light source in a protective enclosure and a temporary connection (example: a construction site lighting chain). A CBC connector is a connector designed to be engaged or disengaged when live or under load.

CLASSIFICATION (20.5). According to Section 2 of Part 1, except that lighting chains are classified only as Class II or Class III, and lighting chains for outdoor use have degree of protection IP 44 or higher.

MARKING (20.6). On the chain: rated voltage and rated wattage of the complete chain; where the information is on the cable — on a durable, non-removable sleeve or label. Chains for indoor use only: "FOR INDOOR USE ONLY" on the chain and the packaging, or the symbol IEC 60417-5957 (2004-12) explained in the instructions. On the packaging or in the instructions (20.6.4), among others: do not connect the chain while in the packaging; with replaceable light sources — voltage and wattage or article number of replacement light sources and do not remove or insert them while the chain is connected; with series-connected light sources — replace failed ones immediately by the same type; "fuse" light sources partly coloured white; with non-replaceable light sources in Class II — do not use the chain with a damaged light source; the gasket warning; interconnection rules (only with the supplied connectors, maximum length and number of light sources or system wattage); for mains voltage chains with series-connected lamps — "WARNING – RISK OF ELECTRIC SHOCK IF LAMPS ARE BROKEN OR MISSING. DO NOT USE.".

CONSTRUCTION (20.7). Section 4 of Part 1 applies; TPL chains comply with the requirements for rough service luminaires of Part 1. Non-standardized (push-in) lampholders are tested as part of the chain; Edison screw lampholders E5, E10, E14 and E27 — according to IEC 60238, bayonet lampholders — according to IEC 61184. Insulation piercing terminals are allowed only in the SELV circuit or as permanent, non-rewireable connections in Class II chains. E5 and E10 and similar small push-in lampholders only if the rated voltage of each light source does not exceed: 25 V (E5 and similar), 60 V (series-connected E10), 250 V (parallel-connected E10); lampholders have a body of insulating material (check: inspection). Clause 4.6 of Part 1 (terminal blocks) does not apply (20.7.3). Interconnecting connectors additionally comply with Annex A; plugs and socket-outlets of TPL chains — IEC 60309-1 (20.7.4). Gaskets of outdoor chains are weather resistant, remain on the chain when the light source is removed and fit tightly round the inserted light source — checked by inspection and by hand; according to a note, a test of the weather resistance of gaskets is under consideration (20.7.5). The mechanical strength of Edison screw and small push-in lampholders is checked by the tests of Clause 16 of IEC 60238:2016 (the free fall test for E5 and E10 also for push-in lampholders), bayonet lampholders — by Clause 16 of IEC 61184:2017, on three samples of the lampholder without the light source; plugs and connectors incorporated in the chain — according to 4.13.6 of Part 1 (20.7.6). Devices bridging lamp filaments in series chains shall not impair protection against electric shock and fire (20.7.7, test of 20.13.3). Control units forming part of the chain are enclosed in non-flammable insulating material and securely fixed to the cable; electronic control units (e.g. flasher units) — also IEC 61347-2-11, LED controlgear — IEC 61347-2-13 (20.7.8).

WHERE A SEEMINGLY CORRECT RESULT IS EASY TO GET. For chains with non-standardized or non-replaceable light sources the light sources are part of the chain — testing the chain alone with other light sources is not testing the product. The mechanical tests of lampholders are carried out on three samples without an inserted light source.

WHAT WE DO NOT GIVE HERE. Clauses 20.7.9–20.7.12 (lamp rotation, lamp insertion and withdrawal force, lamp mechanical requirements, TPL chains) and 20.8–20.16 (creepage distances and clearances, earthing, terminals, wiring — Tables 1 and 2, cord anchorage test, plugs and cable length, maximum length of extendable Class II chains, protection against electric shock — divisible plug, electrification of decorations, contacts of push-in lampholders, blanking plugs, endurance and thermal tests — test voltage, lamp bridging devices, short-circuit test of rectifier, dust and moisture, insulation, resistance to heat and fire) or Annex A (connectors) — the sample breaks off at 20.7.8; we know them only from the titles in the table of contents. We have not read the content of amendment A11:2024 (6 pages).

STATUS (as of 26.11.2026). PKN card: PN-EN IEC 60598-2-20:2024-10 "Oprawy oświetleniowe -- Część 2-20: Wymagania szczegółowe -- Girlandy świetlne" — English version (published 07-10-2024, 30 pages), KT 4 (lighting technology), implements EN IEC 60598-2-20:2024 [IDT] and IEC 60598-2-20:2022 [IDT], replaces PN-EN 60598-2-20:2015-07 (English version) and PN-EN 60598-2-20:2015-07/AC:2017-03; additional element: amendment PN-EN IEC 60598-2-20:2024-10/A11:2024-11 (published 19-11-2024, 6 pages, implements EN IEC 60598-2-20:2024/A11:2024 [IDT]). The card of the previous edition PN-EN 60598-2-20:2015-07 gives the withdrawal date 07-10-2024 and replacement by PN-EN IEC 60598-2-20:2024-10.

Method principle

The lighting chain is tested according to IEC 60598-1 in the order of the Part 1 sections, with the additional requirements of Part 2-20: the protection class (only II or III) and IP degree (at least IP 44 outdoors), the marking of the chain and packaging and the choice of lampholders for the voltage of the light sources are checked, and the mechanical strength of lampholders — by the tests of Clause 16 of IEC 60238:2016 or IEC 61184:2017 on three samples without the light source.

Applications

Key parameters

ParameterValue
STATUS (as of 26.11.2026)PKN card: PN-EN IEC 60598-2-20:2024-10 — English version (07-10-2024, 30 pages), KT 4 (lighting technology), implements EN IEC 60598-2-20:2024 [IDT] and IEC 60598-2-20:2022 [IDT], replaces PN-EN 60598-2-20:2015-07 and its corrigendum AC:2017-03; amendment A11:2024-11 (19-11-2024, 6 pages). PN-EN 60598-2-20:2015-07 — withdrawn 07-10-2024.
Scope (20.1)lighting chains, supply voltage up to 250 V, indoors and outdoors; permanently installed, temporarily installed and temporarily installed protected (TPL)
Classification (20.5)Class II or III only; outdoor chains — IP 44 or higher
E5 and E10 lampholders (20.7.2)rated voltage of each light source not exceeding: 25 V (E5 and similar small), 60 V (E10 in series), 250 V (E10 in parallel); body of insulating material
Insulation piercing terminals (20.7.2)only in the SELV circuit or as permanent, non-rewireable connections in Class II chains
Mechanical strength of lampholders (20.7.6)Clause 16 of IEC 60238:2016 (Edison screw and push-in, with the E5/E10 free fall test) or IEC 61184:2017 (bayonet); 3 samples without the light source
TPL chains (20.7.1, 20.7.4)requirements for rough service luminaires of Part 1; plugs and socket-outlets according to IEC 60309-1
Control units (20.7.8)non-flammable insulating material, secure fixing to the cable; flasher units — IEC 61347-2-11, LED controlgear — IEC 61347-2-13

Standard

Standard number
PN-EN IEC 60598-2-20:2024-10 (English version, published 07-10-2024; implements EN IEC 60598-2-20:2024 and IEC 60598-2-20:2022 [IDT]) with amendment PN-EN IEC 60598-2-20:2024-10/A11:2024-11
Title (PL)
Oprawy oświetleniowe — Część 2-20: Wymagania szczegółowe — Girlandy świetlne
Title (EN)
Luminaires — Part 2-20: Particular requirements — Lighting chains

Step-by-step procedure

  1. Tests according to IEC 60598-1

    Provisions of Section 0 of Part 1; tests of the Part 1 sections in the order listed in Part 2-20 (20.4); classification: Class II or III, at least IP 44 outdoors (20.5).

  2. Marking

    Voltage and wattage of the complete chain on a durable sleeve or label; "indoor use only" text or symbol; information on the packaging or in the instructions according to the type of chain (20.6.2–20.6.4).

  3. Construction and lampholders

    Choice of lampholders for the voltage of the light sources, insulation piercing terminals, connectors (Annex A), gaskets of outdoor chains, bridging devices and control units (20.7.2–20.7.8).

  4. Mechanical strength of lampholders

    Tests of Clause 16 of IEC 60238:2016 or IEC 61184:2017 on three lampholder samples without the light source; after the test — requirements of 4.13 of Part 1 (20.7.6).

Required equipment and apparatus

EquipmentExampleIndicative price
Equipment for mechanical tests of lampholders according to Clause 16 of IEC 60238:2016 and IEC 61184:2017 (20.7.6)Three lampholder samples without the light source; for E5, E10 and push-in lampholders also the free fall test—
Equipment for degree of protection tests according to IEC 60529 (20.5.3)Outdoor chains — at least IP 44—

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-EN IEC 60598-2-20:2024-10 (English version, published 07-10-2024; implements EN IEC 60598-2-20:2024 and IEC 60598-2-20:2022 [IDT]) with amendment PN-EN IEC 60598-2-20:2024-10/A11:2024-11 — “Luminaires — Part 2-20: Particular requirements — Lighting chains”.

How does this method work?

The lighting chain is tested according to IEC 60598-1 in the order of the Part 1 sections, with the additional requirements of Part 2-20: the protection class (only II or III) and IP degree (at least IP 44 outdoors), the marking of the chain and packaging and the choice of lampholders for the voltage of the light sources are checked, and the mechanical strength of lampholders — by the tests of Clause 16 of IEC 60238:2016 or IEC 61184:2017 on three samples without the light source.

What is the measuring range and accuracy?

STATUS (as of 26.11.2026): PKN card: PN-EN IEC 60598-2-20:2024-10 — English version (07-10-2024, 30 pages), KT 4 (lighting technology), implements EN IEC 60598-2-20:2024 [IDT] and IEC 60598-2-20:2022 [IDT], replaces PN-EN 60598-2-20:2015-07 and its corrigendum AC:2017-03; amendment A11:2024-11 (19-11-2024, 6 pages). PN-EN 60598-2-20:2015-07 — withdrawn 07-10-2024.; Scope (20.1): lighting chains, supply voltage up to 250 V, indoors and outdoors; permanently installed, temporarily installed and temporarily installed protected (TPL); Classification (20.5): Class II or III only; outdoor chains — IP 44 or higher; E5 and E10 lampholders (20.7.2): rated voltage of each light source not exceeding: 25 V (E5 and similar small), 60 V (E10 in series), 250 V (E10 in parallel); body of insulating material.

How long does the test take?

The procedure comprises 4 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.

What equipment is required?

Equipment for mechanical tests of lampholders according to Clause 16 of IEC 60238:2016 and IEC 61184:2017 (20.7.6), Equipment for degree of protection tests according to IEC 60529 (20.5.3).

Where is this test used?

Permanently installed lighting chains (e.g. lighting of ski tracks, promenades), permanently connected to the fixed wiring (20.3.4); Temporarily installed lighting chains, including Christmas tree and decorative chains (20.3.5); Temporarily installed protected lighting (TPL) chains for building sites — as rough service luminaires, plugs and socket-outlets according to IEC 60309-1 (20.3.6, 20.7.1, 20.7.4); Lighting chains with ornamental attachments, with replaceable, non-replaceable and non-standardized light sources (20.1).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN IEC 60598-2-20.