🏗️ Hinged or pivoted doors — resistance to static torsion: door leaf open at (90 ± 5)° with the top lockside corner fixed, preload (200 ± 4) N at the lower corner, then load F for (300 ± 5) s, measurement of the deformation under load and of the residual deformation after (180 ± 5) s with a 0.01 mm gauge, result to 0.1 mm; PN-EN 948
In short
Determination of the permanent deformation of a hinged or pivoted door leaf under static torsional load. The test is performed according to PN-EN 948:2000 (Polish version; implements EN 948:1999 [IDT]); STATUS (PKN card as of 11.11.2026): PN-EN 948:2000 current (Polish version); implements EN 948:1999; replaced PN-EN 129:1998. The procedure comprises 5 steps; it is used for: All vertically hung doors — hinged and pivoted; leaf in its own frame as part of a doorset (EN 948:1999, clause 1), Replaced in PN the standard PN-EN 129:1998 (PKN card); EN 948 replaced EN 129:1984 (foreword), Leaves sold without a frame — testing in a typical frame indicated by the manufacturer (clause 1, introduction).
At a glance
- Standard: PN-EN 948:2000 (Polish version; implements EN 948:1999 [IDT])
- Category: Construction
- Procedure steps: 5
- STATUS (PKN card as of 11.11.2026): PN-EN 948:2000 current (Polish version); implements EN 948:1999; replaced PN-EN 129:1998
- Position of the leaf — condition (clause 4): angle (90 ± 5)° to the plane of the frame, without vertical restraint; top lockside corner fixed (50 ± 5) mm from the edge
- Preload — condition (clause 4): (200 ± 4) N at the lower lockside corner, (50 ± 5) mm from the edge, for (60 ± 5) s; measurement (60 ± 5) s after removal
Overview
WHAT THE STANDARD COVERS. According to clause 1 of EN 948:1999 the standard applies to all vertically hinged or pivoted doors and specifies the method to be used to determine the permanent deformation caused when static stress in torsion is applied to an open door leaf fixed in its own door frame as part of a doorset. Note to clause 1: torsional stresses that might reasonably be expected, such as in attempts to free a door which sticks, should neither damage nor impair the performance of a door. The method may also be used for a door leaf submitted for test in a frame which the manufacturer considers appropriate and typical for the intended use. Introduction: manufacturers of door leaves sold without a frame may claim compliance by testing the leaf in a typical frame, but this does not necessarily mean that a door assembly incorporating that leaf will meet the requirements.
ACCORDING TO THE TEXT OF EN 948:1999 — APPARATUS, TEST SPECIMENS, PROCEDURE, RESULTS, TEST REPORT (foreword, introduction, clauses 1–6, Figure 1). The standard was prepared by CEN/TC 33 "Doors, windows, shutters and building hardware" (secretariat AFNOR); it replaces EN 129:1984; national implementation at the latest by February 2000; it was prepared taking into account ISO 9381 and EN 129. Apparatus (clause 2): test surround sufficiently rigid to withstand the test load without deflecting to an extent likely to influence the result; loading equipment — weights or a controlled and calibrated ram, accurate to 2 %; dial or digital gauge accurate to 0.01 mm. Test specimens (clause 3): stored and tested in a non-destructive environment within 15–30 °C and 25–75 % relative humidity; doors designed to be glazed are supplied for testing with all glazing according to the manufacturer's specification. Procedure (clause 4): without any vertical restraint the leaf is positioned at an angle of (90 ± 5)° to the plane of the frame and the top lockside corner is fixed at a point (50 ± 5) mm from each edge of the leaf; to take up any slack in the hinges a preload of (200 ± 4) N is carefully applied horizontally and normal to the plane of the leaf at the lower lockside corner, at a point (50 ± 5) mm from each edge, maintained for (60 ± 5) s, removed, and after (60 ± 5) s the location of the lower corner at the loading position is measured to the nearest 0.1 mm (Figure 1); a static load F is applied to the same point and maintained for (300 ± 5) s; the maximum deformation under load is measured to the nearest 0.1 mm; after removal of the load and (180 ± 5) s the measurement at the lower corner is repeated. All loads are applied and removed carefully in increments of maximum 100 N, accurate to 2 %, with at least 1 s per increment, or at an equivalent rate if continuous — to avoid dynamic effects. Result (clause 5): the deformation under load F and the residual deformation of the leaf — the difference between the measurements at the lower corner before application of load F and (180 ± 5) s after its removal. Test report (clause 6): reference to the standard; identification of the doorset or leaf; type, dimensions, materials, form and construction, including the position of hardware; full details of the frame and hardware if the assembly is not a doorset; storage and test conditions; load F in newtons; results according to clause 5; damage that appeared during the test; name of the laboratory; date of test.
STATUS (PKN card as of 11.11.2026). The card for PN-EN 948:2000 (Polish version) has no withdrawal label: published 07-12-2000, 6 pages, KT 169 for Windows, Doors, Shutters and Hardware, "Implements: EN 948:1999 [IDT]", "Replaces: PN-EN 129:1998 - Polish version", ICS 91.060.50; "Scope" field: "The standard covers all types of door leaves hung vertically on hinges or a pivot. The method used to determine permanent deformation caused by static torsional stresses applied to an open door leaf fixed in its own frame, which is part of a doorset, is given". The PKN search (term "PN-EN 948", 11.11.2026) returns one card of this standard (the other hits are other numbers). iTeh catalogue (read 11.11.2026): SIST EN 948:2000 — status "Published".
HOW MANY LABORATORIES AND IN WHAT FORM (accreditation scope database of the service, read 11.11.2026). The notation EN 948 appears in 13 records at 5 Polish laboratories: AB 023 (5), AB 1054 (4), AB 014 (2), AB 661 (1 — "PN-EN 948:2000 „N”") and AB 1596 (1 — alongside PN-EN 1192:2001 with an asterisk). In 6 records (AB 014, AB 023, AB 1054) the characteristic tested is "load-bearing capacity of safety devices" with the notation "PN-EN 948 „N”" alongside PN-EN 14351-1. Outside Poland — 7 records at 7 Czech laboratories (1007.1, 1018.3, 1026, 1030.1, 1031, 1095, 1234: "ČSN EN 948", partly alongside ČSN EN 947, ČSN EN 14608 and ČSN EN 14609); three other Czech hits of the number 948 concern other documents (AOAC 948.26, SOP 948.01, ČSN EN ISO 948) and are not counted. In the current PCA scope of AB 1596 (issue 20 of 02.09.2026, downloaded 11.11.2026) "N" means a method used in activities relevant to notification under Regulation (EU) No 305/2011, "*" — tests on the basis of whose results the laboratory formulates opinions and interpretations, "+" — tests at the premises and outside; the document does not mark the EN 948 item as suspended. We have not compared the PCA scope documents of the other laboratories with the database.
WHAT THE LABORATORIES TEST (scope database, complete items — 13 Polish). Doors, doorsets, leaves, frames (AB 014, AB 023 — including internal and external, hinged, sliding, folding, swing), external doors (AB 1054), hinged doors (AB 661), doors (AB 1596) — strength (resistance) to static torsion; AB 014, AB 023 and AB 1054 also load-bearing capacity of safety devices. The text of EN 948 concerns hinged and pivoted doors — it does not name sliding or folding doors.
WHERE AN APPARENTLY CORRECT RESULT IS EASY TO GET. Set-up: leaf also restrained vertically or opening angle outside (90 ± 5)°; fixing point and loading point further than (50 ± 5) mm from the edges; test surround deflecting under load. Loading: preload of (200 ± 4) N omitted — hinge slack enters the result; applying the load in steps larger than 100 N or faster than 1 s per increment — dynamic effects; times (60 ± 5) s, (300 ± 5) s and (180 ± 5) s. Result: the residual deformation is the difference from the measurement after the preload, not from the position before it; the report must state load F. Specimen: glazed doors tested without glazing; temperature and humidity outside 15–30 °C and 25–75 %. The standard does not give the value of load F.
WHAT WE DO NOT GIVE. Parts read: the iTeh sample of SIST EN 948:2000 (EN 948:1999 in English: foreword, introduction, clauses 1–6 and Figure 1 — scan read from the page images). We do not give the value of load F or resistance classes — EN 948 does not contain them; we have not read EN 1192 (classification of the strength of doors), PN-EN 14351-1 or ISO 9381.
Method principle
The leaf of a hinged or pivoted door, fitted in its own frame, is positioned without vertical restraint at (90 ± 5)° and its top lockside corner is fixed (50 ± 5 mm from the edges); at the lower lockside corner a preload of (200 ± 4) N for (60 ± 5) s and then a load F for (300 ± 5) s are applied horizontally and normal to the leaf, in increments of at most 100 N. With a 0.01 mm gauge the position of the corner after the preload, the maximum deformation under F and the position (180 ± 5) s after removal of F are measured to 0.1 mm; the result is the deformation under load and the residual deformation (EN 948:1999, clauses 2–5).
Applications
- All vertically hung doors — hinged and pivoted; leaf in its own frame as part of a doorset (EN 948:1999, clause 1)
- Replaced in PN the standard PN-EN 129:1998 (PKN card); EN 948 replaced EN 129:1984 (foreword)
- Leaves sold without a frame — testing in a typical frame indicated by the manufacturer (clause 1, introduction)
- Situations such as attempts to free a door which sticks — torsion should neither damage the door nor impair its performance (note to clause 1)
- In accreditation scopes: 5 Polish laboratories — doors, doorsets, leaves and frames; also load-bearing capacity of safety devices
Key parameters
| Parameter | Value |
|---|---|
| STATUS (PKN card as of 11.11.2026) | PN-EN 948:2000 current (Polish version); implements EN 948:1999; replaced PN-EN 129:1998 |
| Position of the leaf — condition (clause 4) | angle (90 ± 5)° to the plane of the frame, without vertical restraint; top lockside corner fixed (50 ± 5) mm from the edge |
| Preload — condition (clause 4) | (200 ± 4) N at the lower lockside corner, (50 ± 5) mm from the edge, for (60 ± 5) s; measurement (60 ± 5) s after removal |
| Load F — condition (clause 4) | at the same point, for (300 ± 5) s; the value of F is given by the specification — EN 948 does not give it |
| Application of loads — condition (clause 4) | increments of at most 100 N accurate to 2 %, at least 1 s per increment, or an equivalent continuous rate |
| Measurement — condition (2.3, clause 4) | dial or digital gauge 0.01 mm; reading to 0.1 mm; after removal of F measurement after (180 ± 5) s |
| Specimens — condition (clause 3) | 15–30 °C, relative humidity 25–75 %; doors designed to be glazed — with glazing according to the manufacturer |
| Result (clause 5) | deformation under load F and residual deformation (difference at the lower corner before F and (180 ± 5) s after removal of F) |
| Coverage in accreditation scopes (database, read 11.11.2026) | 5 Polish laboratories, 13 records; 7 Czech laboratories |
Standard
- Standard number
- PN-EN 948:2000 (Polish version; implements EN 948:1999 [IDT])
- Title (PL)
- Drzwi rozwierane — Oznaczanie wytrzymałości na skręcanie statyczne
- Title (EN)
- Hinged or pivoted doors — Determination of the resistance to static torsion
Step-by-step procedure
-
Specimen and conditions
Doorset or leaf in a typical frame; storage and testing at 15–30 °C and 25–75 % relative humidity; doors designed to be glazed with glazing (clause 3).
-
Set-up
Leaf without vertical restraint at (90 ± 5)° to the frame; top lockside corner fixed at a point (50 ± 5) mm from each edge (clause 4).
-
Preload
(200 ± 4) N horizontally and normal to the leaf at the lower lockside corner, (50 ± 5) mm from the edge, for (60 ± 5) s; after removal and (60 ± 5) s measurement of the corner position to 0.1 mm (clause 4, Figure 1).
-
Load F
At the same point a static load F for (300 ± 5) s, increments ≤ 100 N, ≥ 1 s per increment; maximum deformation under load to 0.1 mm; after removal and (180 ± 5) s measurement repeated (clause 4).
-
Result and test report
Deformation under F and residual deformation (clause 5); the report includes among other things load F in newtons, damage, storage and test conditions (clause 6). PN-EN 948:2000 — current (PKN card as of 11.11.2026).
Required equipment and apparatus
| Equipment | Example | Indicative price |
|---|---|---|
| Test surround (2.1) | Sufficiently rigid not to deflect under load to an extent influencing the result | — |
| Loading equipment (2.2) | Weights or a controlled and calibrated ram, accuracy 2 % | — |
| Displacement gauge (2.3) | Dial or digital, accuracy 0.01 mm | — |
Health and safety (OHS)
- Loading a door leaf with weights or a ram — protection against falling weights and sudden release of the leaf
- The standard gives no hazards of the test — NOT GIVEN
- TECHNICAL NOTE: the value of load F and the requirements are given by the product specification or classification — not by EN 948
Frequently asked questions
Which standard describes this test?
The test is performed according to PN-EN 948:2000 (Polish version; implements EN 948:1999 [IDT]) — “Hinged or pivoted doors — Determination of the resistance to static torsion”.
How does this method work?
The leaf of a hinged or pivoted door, fitted in its own frame, is positioned without vertical restraint at (90 ± 5)° and its top lockside corner is fixed (50 ± 5 mm from the edges); at the lower lockside corner a preload of (200 ± 4) N for (60 ± 5) s and then a load F for (300 ± 5) s are applied horizontally and normal to the leaf, in increments of at most 100 N. With a 0.
What is the measuring range and accuracy?
STATUS (PKN card as of 11.11.2026): PN-EN 948:2000 current (Polish version); implements EN 948:1999; replaced PN-EN 129:1998; Position of the leaf — condition (clause 4): angle (90 ± 5)° to the plane of the frame, without vertical restraint; top lockside corner fixed (50 ± 5) mm from the edge; Preload — condition (clause 4): (200 ± 4) N at the lower lockside corner, (50 ± 5) mm from the edge, for (60 ± 5) s; measurement (60 ± 5) s after removal; Load F — condition (clause 4): at the same point, for (300 ± 5) s; the value of F is given by the specification — EN 948 does not give it.
How long does the test take?
The procedure comprises 5 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.
What equipment is required?
Test surround (2.1), Loading equipment (2.2), Displacement gauge (2.3).
Where is this test used?
All vertically hung doors — hinged and pivoted; leaf in its own frame as part of a doorset (EN 948:1999, clause 1); Replaced in PN the standard PN-EN 129:1998 (PKN card); EN 948 replaced EN 129:1984 (foreword); Leaves sold without a frame — testing in a typical frame indicated by the manufacturer (clause 1, introduction); Situations such as attempts to free a door which sticks — torsion should neither damage the door nor impair its performance (note to clause 1); In accreditation scopes: 5 Polish laboratories — doors, doorsets, leaves and frames; also load-bearing capacity of safety devices.
What safety precautions apply?
Loading a door leaf with weights or a ram — protection against falling weights and sudden release of the leaf; The standard gives no hazards of the test — NOT GIVEN; TECHNICAL NOTE: the value of load F and the requirements are given by the product specification or classification — not by EN 948.
Which laboratory can perform this test?
The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 948.