💥 Explosive atmospheres — non-electrical equipment: ignition hazard assessment, equipment protection levels (EPL) and Groups I, II, III, ignition sources (hot surfaces, mechanically generated sparks, static electricity, adiabatic compression), tests and marking; PN-EN ISO 80079-36

Electronics and EMC PN-EN ISO 80079-36

In short

Basic method and requirements for the design, construction, testing and marking of non-electrical Ex equipment, Ex components, protective systems and their assemblies which have their own potential ignition sources and are intended for explosive atmospheres. The test is performed according to PN-EN ISO 80079-36:2016-07 (Polish and English version; implements EN ISO 80079-36:2016 and ISO 80079-36:2016 [IDT]) with corrigendum PN-EN ISO 80079-36:2016-07/AC:2020-05; STATUS (as of 18.11.2026): PKN cards: PN-EN ISO 80079-36:2016-07 “Atmosfery wybuchowe -- Część 36: Urządzenia nieelektryczne do atmosfer wybuchowych -- Metodyka i wymagania” — English version (published 05-07-2016, 100 pages) and Polish version (published 04-01-2018, 88 pages), KT 269 Chemical Safety, implements EN ISO 80079-36:2016 and ISO 80079-36:2016 [IDT], replaces PN-EN 13463-1:2010; corrigenda: PN-EN ISO 80079-36:2016-07/AC:2020-05 (English and Polish version); the cards give no withdrawal date. iTeh catalogue: EN ISO 80079-36:2016 — published 06.04.2016, status “Published”; corrigendum EN ISO 80079-36:2016/AC:2019 — published 18.12.2019. The procedure comprises 4 steps; it is used for: Non-electrical Ex equipment, Ex components, protective systems and their assemblies with their own potential ignition sources, e.g. couplings, pumps, gearboxes, brakes, hydraulic and pneumatic motors, fans, compressors (introduction, clause 1), Ignition hazard assessment of mechanical equipment of Group I (mining), II (gas atmospheres) and III (combustible dusts) before conformity assessment under Directive 2014/34/EU (Annex ZA), Determination of the maximum surface temperature, mechanical tests and tests of non-metallic parts of non-electrical equipment (clause 8, table of contents).

At a glance

  • Standard: PN-EN ISO 80079-36:2016-07 (Polish and English version; implements EN ISO 80079-36:2016 and ISO 80079-36:2016 [IDT]) with corrigendum PN-EN ISO 80079-36:2016-07/AC:2020-05
  • Category: Electronics and EMC
  • Procedure steps: 4
  • STATUS (as of 18.11.2026): PKN cards: PN-EN ISO 80079-36:2016-07 “Atmosfery wybuchowe -- Część 36: Urządzenia nieelektryczne do atmosfer wybuchowych -- Metodyka i wymagania” — English version (published 05-07-2016, 100 pages) and Polish version (published 04-01-2018, 88 pages), KT 269 Chemical Safety, implements EN ISO 80079-36:2016 and ISO 80079-36:2016 [IDT], replaces PN-EN 13463-1:2010; corrigenda: PN-EN ISO 80079-36:2016-07/AC:2020-05 (English and Polish version); the cards give no withdrawal date. iTeh catalogue: EN ISO 80079-36:2016 — published 06.04.2016, status “Published”; corrigendum EN ISO 80079-36:2016/AC:2019 — published 18.12.2019.
  • Standard atmospheric conditions (clause 1): temperature −20 °C to +60 °C; pressure 80 kPa to 110 kPa (0,8 bar to 1,1 bar); air with oxygen content typically 21 % v/v
  • Ambient temperature of the equipment (clause 1, note 2): −20 °C to +40 °C unless otherwise specified and marked

Overview

WHAT THE STANDARD COVERS. According to clause 1 of ISO 80079-36:2016 the standard specifies the basic method and requirements for the design, construction, testing and marking of non-electrical Ex equipment, Ex components, protective systems, devices and assemblies of these products that have their own potential ignition sources and are intended for use in explosive atmospheres. Hand tools and manually operated equipment without energy storage are excluded; the standard also does not address the safety of static autonomous process equipment (tanks, vessels, fixed pipework, hand-operated valves) when it is not part of equipment covered by the standard. The requirements cover only safety directly related to the risk of ignition which may lead to an explosion, and all equipment protection levels (EPL) of Groups I, II and III.

ACCORDING TO THE TEXT OF ISO 80079-36:2016 (publisher's sample: contents, foreword, introduction, clause 1 with Table 1) and EN ISO 80079-36:2016 (SIST sample: European foreword, Annexes ZA, ZB and ZC). The standard was prepared by IEC subcommittee SC 31M (non-electrical equipment and protective systems for explosive atmospheres) of IEC TC 31. According to the introduction it is the first standard to address, at international level, the basic requirements and protection concepts for mechanical explosion-protected equipment; examples of non-electrical equipment are couplings, pumps, gearboxes, brakes, hydraulic and pneumatic motors and their combinations into a machine, fan, engine, compressor or assembly. The introduction names two ignition scenarios: a failure of the machine (e.g. an overheated bearing) and the normal functioning of the machine (e.g. a hot brake surface). Potential ignition sources also include those created by the operation of the equipment, for example hot surfaces when pumping hot fluids or electrostatic charging when handling plastics.

ATMOSPHERIC CONDITIONS (clause 1). Standard atmospheric conditions under which the equipment may be assumed to operate: temperature from −20 °C to +60 °C, pressure from 80 kPa (0,8 bar) to 110 kPa (1,1 bar) and air with normal oxygen content, typically 21 % v/v. The normal ambient temperature range of the equipment is from −20 °C to +40 °C unless otherwise specified and marked (note 2). The standard supplements and modifies the general requirements of IEC 60079-0 according to Table 1 (in case of conflict ISO 80079-36 takes precedence), and for types of protection it is supplemented by ISO 80079-37 (constructional safety “c”, control of ignition source “b”, liquid immersion “k”) and by IEC 60079-1 “d”, IEC 60079-2 “p” and IEC 60079-31 “t”.

CONTENT (table of contents). Clause 4 — EPL and equipment groups (Group I, II, III, equipment for a specific explosive gas atmosphere); clause 5 — ignition hazard assessment (formal identification and assessment, assessment of Group I and of Group II and III equipment, assessment with malfunctions, basic information, assessment report); clause 6 — assessment of possible ignition sources and control means: hot surfaces (ambient temperature, establishing the maximum surface temperature), flames and hot gases, mechanically generated sparks and hot surfaces (single impacts, friction, external parts of light metals), electrical ignition sources, stray currents and cathodic protection, static electricity, adiabatic compression and shock waves, exothermic reactions; clause 7 — among others dust deposits in the gap of moving parts, opening times of enclosures, non-metallic parts, light-transmitting parts, stored energy; clause 8 — verification and tests: determination of the maximum surface temperature and hot surface ignition test, mechanical tests (impact, drop test), additional tests of non-metallic parts (thermal endurance to heat and cold, chemical resistance for Group I, surface resistance, thermal shock); clauses 9–11 — documentation, instructions and marking. The sample does not contain the text of clauses 4–11, so we do not give the test conditions.

EN ISO 80079-36:2016 (SIST sample). The European version was approved by CEN on 18 February 2016; national implementation and withdrawal of conflicting standards — at the latest by October 2016; it supersedes EN 13463-1:2009 and supports the essential requirements of Directive 2014/34/EU (Annex ZA). According to Table ZB.1: Group I — EPL Ma/Mb corresponds to categories M1/M2; Group II — Ga, Gb, Gc corresponds to categories 1G, 2G, 3G and Zones 0, 1, 2; Group III — Da, Db, Dc corresponds to categories 1D, 2D, 3D and Zones 20, 21, 22. Marking examples: “Ex h I Mb” (I M2, mining), “Ex h IIB T4 Gb” (II 2 G, Zone 1), “Ex h IIIC 120°C Da” (II 1 D, Zone 20). Table ZC.1 lists the significant changes from EN 13463-1:2009, among others EPL instead of category, dust groups IIIA, IIIB, IIIC and requirements for external hot surfaces; there are no changes classified as major technical changes.

CORRIGENDUM (ISO 80079-36:2016/Cor 1:2019 = EN ISO 80079-36:2016/AC:2019; SIST EN ISO 80079-36:2016/AC:2020 sample). Effective from 18 December 2019. It replaces Table 9 (8.4.4, thermal endurance to heat): for a service temperature Ts ≤ 70 °C — 672 h (+30/0 h) at a relative humidity of (90 ± 5) % and a temperature of Ts + (20 ± 2) °C, not lower than 80 °C; for 70 °C < Ts ≤ 75 °C — the same or alternatively 504 h (+30/0 h) at (90 ± 5) % RH and (90 ± 2) °C, followed by 336 h (+30/0 h) dry at Ts + (20 ± 2) °C; for Ts > 75 °C — 336 h (+30/0 h) at (90 ± 5) % RH and (95 ± 2) °C, followed by 336 h dry at Ts + (20 ± 2) °C, or alternatively 504 h at (90 ± 5) % RH and (90 ± 2) °C, followed by 336 h dry at Ts + (20 ± 2) °C; Ts is the temperature defined in 3.8 without the increase stated in 8.4.1. In 11.2 it adds item o): Ex components shall not include a temperature class or maximum surface temperature marking. In 8.2.1 b) it corrects a typing error (English version only).

STATUS (as of 18.11.2026). PKN cards: PN-EN ISO 80079-36:2016-07 “Atmosfery wybuchowe -- Część 36: Urządzenia nieelektryczne do atmosfer wybuchowych -- Metodyka i wymagania” — English version (published 05-07-2016, 100 pages) and Polish version (published 04-01-2018, 88 pages), KT 269 Chemical Safety, implements EN ISO 80079-36:2016 and ISO 80079-36:2016 [IDT], replaces PN-EN 13463-1:2010; corrigenda: PN-EN ISO 80079-36:2016-07/AC:2020-05 (English and Polish version); the cards give no withdrawal date. iTeh catalogue: EN ISO 80079-36:2016 — published 06.04.2016, status “Published”; corrigendum EN ISO 80079-36:2016/AC:2019 — published 18.12.2019.

Method principle

Ignition hazard assessment: all potential ignition sources of the complete equipment (created by the equipment and by its operation) are identified, and it is assessed whether they can become effective during the expected lifetime — in normal operation and with malfunctions. On this basis protective measures appropriate to the required equipment protection level (EPL) are chosen, and the result is documented in the assessment report, the tests and the “Ex h” marking.

Applications

Key parameters

ParameterValue
STATUS (as of 18.11.2026)PKN cards: PN-EN ISO 80079-36:2016-07 “Atmosfery wybuchowe -- Część 36: Urządzenia nieelektryczne do atmosfer wybuchowych -- Metodyka i wymagania” — English version (published 05-07-2016, 100 pages) and Polish version (published 04-01-2018, 88 pages), KT 269 Chemical Safety, implements EN ISO 80079-36:2016 and ISO 80079-36:2016 [IDT], replaces PN-EN 13463-1:2010; corrigenda: PN-EN ISO 80079-36:2016-07/AC:2020-05 (English and Polish version); the cards give no withdrawal date. iTeh catalogue: EN ISO 80079-36:2016 — published 06.04.2016, status “Published”; corrigendum EN ISO 80079-36:2016/AC:2019 — published 18.12.2019.
Standard atmospheric conditions (clause 1)temperature −20 °C to +60 °C; pressure 80 kPa to 110 kPa (0,8 bar to 1,1 bar); air with oxygen content typically 21 % v/v
Ambient temperature of the equipment (clause 1, note 2)−20 °C to +40 °C unless otherwise specified and marked
Exclusions (clause 1)hand tools and manually operated equipment without energy storage; static autonomous process equipment outside the equipment covered by the standard
Related standards (clause 1, Table 1)supplements and modifies IEC 60079-0; types of protection: ISO 80079-37 (“c”, “b”, “k”), IEC 60079-1 “d”, IEC 60079-2 “p”, IEC 60079-31 “t”
EPL versus categories and zones (Table ZB.1)Ma/Mb — M1/M2; Ga/Gb/Gc — 1G/2G/3G, Zones 0/1/2; Da/Db/Dc — 1D/2D/3D, Zones 20/21/22
Marking examples (Annex ZB)Ex h I Mb; Ex h IIB T4 Gb; Ex h IIIC 120°C Da
European version (EN foreword)approved by CEN on 18.02.2016; supersedes EN 13463-1:2009; Directive 2014/34/EU
Corrigendum AC:2019 / Cor 1:2019 (8.4.4, 11.2)new Table 9 — thermal endurance to heat: Ts ≤ 70 °C: 672 h, (90 ± 5) % RH, Ts + (20 ± 2) °C (≥ 80 °C); Ts > 75 °C: 336 h, (90 ± 5) % RH, (95 ± 2) °C + 336 h dry at Ts + (20 ± 2) °C; Ex components without temperature class marking

Standard

Standard number
PN-EN ISO 80079-36:2016-07 (Polish and English version; implements EN ISO 80079-36:2016 and ISO 80079-36:2016 [IDT]) with corrigendum PN-EN ISO 80079-36:2016-07/AC:2020-05
Title (PL)
Atmosfery wybuchowe — Część 36: Urządzenia nieelektryczne do atmosfer wybuchowych — Metodyka i wymagania
Title (EN)
Explosive atmospheres — Part 36: Non-electrical equipment for explosive atmospheres — Basic method and requirements

Step-by-step procedure

  1. Classification of the equipment

    Determination of the equipment group (I, II or III, for Group II possibly a specific gas atmosphere) and the required equipment protection level EPL (clause 4).

  2. Ignition hazard assessment

    Formal identification and assessment of all potential ignition sources in normal operation and with malfunctions taken into account; assessment report (clause 5).

  3. Protective measures and verification

    Assessment of ignition sources and their control means (clause 6), additional requirements (clause 7), tests: maximum surface temperature, mechanical tests and tests of non-metallic parts (clause 8).

  4. Documentation, instructions and marking

    Technical documentation, instructions for the user and “Ex h” marking with the group, temperature class or maximum surface temperature and EPL (clauses 9–11, Annex ZB).

Required equipment and apparatus

EquipmentExampleIndicative price
Ignition hazard assessment documentation (5.2.6)Assessment report: identified ignition sources, their assessment in normal operation and with malfunctions, protective measures applied—
Set-up for determining the maximum surface temperature (8.2)Measurement of the surface temperature of the equipment under the most unfavourable operating conditions; hot surface ignition test (8.2.2)—
Mechanical test equipment (8.3)Impact test and drop test according to IEC 60079-0 (Table 1: 26.4.2, 26.4.3)—

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-EN ISO 80079-36:2016-07 (Polish and English version; implements EN ISO 80079-36:2016 and ISO 80079-36:2016 [IDT]) with corrigendum PN-EN ISO 80079-36:2016-07/AC:2020-05 — “Explosive atmospheres — Part 36: Non-electrical equipment for explosive atmospheres — Basic method and requirements”.

How does this method work?

Ignition hazard assessment: all potential ignition sources of the complete equipment (created by the equipment and by its operation) are identified, and it is assessed whether they can become effective during the expected lifetime — in normal operation and with malfunctions. On this basis protective measures appropriate to the required equipment protection level (EPL) are chosen, and the result is documented in the assessment report, the tests and the “Ex h” marking.

What is the measuring range and accuracy?

STATUS (as of 18.11.2026): PKN cards: PN-EN ISO 80079-36:2016-07 “Atmosfery wybuchowe -- Część 36: Urządzenia nieelektryczne do atmosfer wybuchowych -- Metodyka i wymagania” — English version (published 05-07-2016, 100 pages) and Polish version (published 04-01-2018, 88 pages), KT 269 Chemical Safety, implements EN ISO 80079-36:2016 and ISO 80079-36:2016 [IDT], replaces PN-EN 13463-1:2010; corrigenda: PN-EN ISO 80079-36:2016-07/AC:2020-05 (English and Polish version); the cards give no withdrawal date. iTeh catalogue: EN ISO 80079-36:2016 — published 06.04.2016, status “Published”; corrigendum EN ISO 80079-36:2016/AC:2019 — published 18.12.2019.; Standard atmospheric conditions (clause 1): temperature −20 °C to +60 °C; pressure 80 kPa to 110 kPa (0,8 bar to 1,1 bar); air with oxygen content typically 21 % v/v; Ambient temperature of the equipment (clause 1, note 2): −20 °C to +40 °C unless otherwise specified and marked; Exclusions (clause 1): hand tools and manually operated equipment without energy storage; static autonomous process equipment outside the equipment covered by the standard.

How long does the test take?

The procedure comprises 4 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.

What equipment is required?

Ignition hazard assessment documentation (5.2.6), Set-up for determining the maximum surface temperature (8.2), Mechanical test equipment (8.3).

Where is this test used?

Non-electrical Ex equipment, Ex components, protective systems and their assemblies with their own potential ignition sources, e.g. couplings, pumps, gearboxes, brakes, hydraulic and pneumatic motors, fans, compressors (introduction, clause 1); Ignition hazard assessment of mechanical equipment of Group I (mining), II (gas atmospheres) and III (combustible dusts) before conformity assessment under Directive 2014/34/EU (Annex ZA); Determination of the maximum surface temperature, mechanical tests and tests of non-metallic parts of non-electrical equipment (clause 8, table of contents); Marking of non-electrical equipment with “Ex h” together with the group, temperature class and EPL (Annex ZB, examples).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN ISO 80079-36.

🔍 Find a laboratory performing this test