🌿 Ethyl acrylate, 2-ethylhexyl acrylate and methacrylic acid in workplace air — gas chromatography with sample enrichment, PN-Z-04113-02 (withdrawn standard)

Environment PN-Z-04113-02

In short

Determination of ethyl acrylate, 2-ethylhexyl acrylate and methacrylic acid vapour in the air surrounding workplaces by gas chromatography with sample enrichment. The test is performed according to PN-Z-04113-02:1978 (Polish version); STATUS (as of 18.11.2026): withdrawn 15-08-2014; card without "Replaced by" and "Replaces" fields; for ethyl acrylate current PN-Z-04570:2026-08 (GC-FID, 1 mg/m³ for 10 l). The procedure comprises 4 steps; it is used for: Measurements of ethyl acrylate and 2-ethylhexyl acrylate vapour in workplace air — assessment against NDS 20 / NDSCh 40 mg/m³ (item 11) and NDS 35 / NDSCh 70 mg/m³ (item 10) (Journal of Laws 2026 item 447); methacrylic acid — no value in the NDS list.

At a glance

  • Standard: PN-Z-04113-02:1978 (Polish version)
  • Category: Environment
  • Procedure steps: 4
  • STATUS (as of 18.11.2026): withdrawn 15-08-2014; card without "Replaced by" and "Replaces" fields; for ethyl acrylate current PN-Z-04570:2026-08 (GC-FID, 1 mg/m³ for 10 l)
  • Edition (from the PKN card): PN-Z-04113-02:1978, Polish version; published 16-09-1978, 4 pages, KT 159 Chemical and Dust Hazards in the Working Environment, ICS 13.040.30
  • Substances and technique (from the card): ethyl acrylate, 2-ethylhexyl acrylate, methacrylic acid; gas chromatography with sample enrichment; the card gives no determinability

Overview

STATUS (as of 18.11.2026). The card of PN-Z-04113-02:1978 (Polish version) has the heading "Withdrawn": published 16-09-1978, withdrawal date 15-08-2014, 4 pages; there are no "Replaced by" or "Replaces" fields. PKN search (18.11.2026): under "akrylanu" the current standard on ethyl acrylate is PN-Z-04570:2026-08 "Ochrona czystości powietrza -- Oznaczanie akrylanu etylu na stanowiskach pracy metodą chromatografii gazowej z detekcją płomieniowo-jonizacyjną" (determination of ethyl acrylate at workplaces by gas chromatography with flame ionisation detection) — according to its card published 13-08-2026, 10 pages, lowest determinable concentration 1 mg/m³ for 10 l of air, no "Replaces" field; under "etyloheksylu" there is no current standard on 2-ethylhexyl acrylate, and under "kwasu metakrylowego" the only standard on this acid is PN-Z-04113-02:1978.

WHAT THE STANDARD COVERS. The scope from the PKN catalogue card, quoted in full: "The method is used to determine the concentration of ethyl acrylate, 2-ethylhexyl acrylate and methacrylic acid vapour in the air surrounding workplaces when checking sanitary and hygienic conditions. This method should not be used in the presence of compounds with the same retention time as ethyl acrylate, 2-ethylhexyl acrylate and methacrylic acid." (our translation; on the card the first occurrence is misspelt "2-etyIoheksylu"). The title refers to gas chromatography with sample enrichment; the card gives neither the sorbent, nor the detector, nor the lowest determinable concentration.

LIMIT VALUES AND THE REGULATION ON THE METHOD. The NDS list — Annex 1 to the regulation of 12 June 2018 as worded by the regulation of 26 March 2026 (Journal of Laws 2026 item 447): item 11 "Ethyl acrylate" [140-88-5] — NDS (8-hour value) 20 mg/m³, NDSCh (short-term value) 40 mg/m³, "skin" notation; item 10 "2-Ethylhexyl acrylate" [103-11-7] — NDS 35 mg/m³, NDSCh 70 mg/m³, "skin" notation. The list does not include methacrylic acid (searched by name and by CAS number 79-41-4). According to the explanatory note to the list, the "skin" notation means that "absorption of the substance through the skin may be as important as exposure by inhalation" (our translation). The method is addressed by § 16 of the regulation on tests and measurements of agents harmful to health in the working environment (consolidated text — Journal of Laws 2025 item 949): "Tests and measurements are performed in accordance with the methods specified in Polish Standards and, where there are no such standards, with methods recommended and validated by the laboratories referred to in § 15(1) and (2)(1)" (our translation). The provision does not name this standard; whether a standard withdrawn by PKN falls under the words "where there are no such standards" — WE DO NOT DECIDE.

PROCEDURE ACCORDING TO THE IMP PROCEDURES (second source; numbers of the procedures, not of the standard). Ethyl acrylate — Bonczarowska, Wziątek, Brzeźnicki, Podstawy i Metody Oceny Środowiska Pracy 2015, no. 2(84), pp. 89–103: a tube of coconut-shell activated carbon (100 mg/50 mg), about 10 l of air at a flow rate of 3.3 l/h, according to PN-Z-04008-7; samples kept in a refrigerator are stable for about three weeks; extraction with a mixture of carbon disulphide and methanol (95 : 5); chromatograph with a flame ionisation detector; determinability 1 mg/m³ — the same as on the card of PN-Z-04570:2026-08. 2-Ethylhexyl acrylate — Wziątek, Janoszka, Gromiec, Podstawy i Metody Oceny Środowiska Pracy 2014, no. 1(79), pp. 55–67: activated carbon (100 mg/50 mg), 10 l of air at a flow rate of up to 1.8 l/h, desorption with a 5 % solution of acetic acid in carbon disulphide, chromatograph with a flame ionisation detector; determinability 3 mg/m³ for 10 l. Neither procedure covers methacrylic acid. We do not transfer the numbers of the procedures to the standard of 1978.

WHAT WE DO NOT GIVE HERE. We did not have the text of PN-Z-04113-02:1978 — PKN sells it (4 pages). We do not give the enrichment technique, sorbent, solvent, air volume, column, detector, determinability or calculations according to the standard. We do not claim that PN-Z-04570:2026-08 replaced PN-Z-04113-02:1978 — the PKN cards do not say so.

Method principle

According to the card of the standard, ethyl acrylate, 2-ethylhexyl acrylate and methacrylic acid vapour is determined by gas chromatography with sample enrichment; the method is not used when compounds with the same retention time are present. The IMP procedures of 2014–2015 trap the acrylates on activated carbon, desorb them with carbon disulphide with added methanol or acetic acid and determine them with a flame ionisation detector. The results are compared with the NDS of 20 mg/m³ (ethyl acrylate) and 35 mg/m³ (2-ethylhexyl acrylate) (NDS list of 2026); the list gives no value for methacrylic acid.

Applications

Key parameters

ParameterValue
STATUS (as of 18.11.2026)withdrawn 15-08-2014; card without "Replaced by" and "Replaces" fields; for ethyl acrylate current PN-Z-04570:2026-08 (GC-FID, 1 mg/m³ for 10 l)
Edition (from the PKN card)PN-Z-04113-02:1978, Polish version; published 16-09-1978, 4 pages, KT 159 Chemical and Dust Hazards in the Working Environment, ICS 13.040.30
Substances and technique (from the card)ethyl acrylate, 2-ethylhexyl acrylate, methacrylic acid; gas chromatography with sample enrichment; the card gives no determinability
Limit values against which the result is assessedethyl acrylate (item 11): NDS 20 mg/m³, NDSCh 40 mg/m³, "skin"; 2-ethylhexyl acrylate (item 10): NDS 35 mg/m³, NDSCh 70 mg/m³, "skin"; methacrylic acid — not in the list (Journal of Laws 2026 item 447)
IMP procedures (numbers of the procedures)ethyl acrylate (2015): activated carbon 100 mg/50 mg, about 10 l, 3.3 l/h, CS₂ with methanol (95 : 5), GC-FID, 1 mg/m³; 2-ethylhexyl acrylate (2014): activated carbon 100 mg/50 mg, 10 l, up to 1.8 l/h, 5 % acetic acid in CS₂, GC-FID, 3 mg/m³

Standard

Standard number
PN-Z-04113-02:1978 (Polish version)
Title (PL)
Ochrona czystości powietrza — Badania zawartości związków akrylowych — Oznaczanie akrylanu etylu, akrylanu 2-etyloheksylu i kwasu metakrylowego metodą chromatografii gazowej z wzbogacaniem próbki
Title (EN)
Air purity protection — Tests for acrylic compounds content — Determination of ethyl acrylate, 2-ethylhexyl acrylate and methacrylic acid by gas chromatography with sample enrichment

Step-by-step procedure

  1. Status of the document

    PKN card: standard withdrawn on 15-08-2014, no successor indicated; for ethyl acrylate current PN-Z-04570:2026-08 (as of 18.11.2026).

  2. Sampling

    With sample enrichment (title of the standard); WE DO NOT GIVE details according to the standard. The IMP procedures sample the acrylates onto activated carbon.

  3. Chromatographic analysis

    Gas chromatography; not to be used when compounds with the same retention time are present (from the card). WE DO NOT GIVE the conditions.

  4. Result and assessment

    The concentration of each compound in mg/m³ against its item of the list: ethyl acrylate NDS 20 mg/m³, 2-ethylhexyl acrylate NDS 35 mg/m³; for methacrylic acid there is no value in the list. "Skin" notation: the measurement in air does not cover absorption through the skin.

Required equipment and apparatus

EquipmentExampleIndicative price
Activated carbon tubes (100 mg/50 mg)IMP procedures 2014 and 2015; WE DO NOT GIVE the enrichment technique according to the standard—
Suction pumpIMP procedure 2015 (ethyl acrylate): about 10 l of air, 3.3 l/h—
Gas chromatograph with flame ionisation detectorIn both IMP procedures; WE DO NOT GIVE the detector according to the standard—

Reagents, media and consumables

ReagentCASDetails
Carbon disulphide with methanol (95 : 5)—Extractant for ethyl acrylate in the IMP procedure 2015 — not according to the standard
5 % solution of acetic acid in carbon disulphide—Desorbent for 2-ethylhexyl acrylate in the IMP procedure 2014 — not according to the standard

Health and safety (OHS)

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-Z-04113-02:1978 (Polish version) — “Air purity protection — Tests for acrylic compounds content — Determination of ethyl acrylate, 2-ethylhexyl acrylate and methacrylic acid by gas chromatography with sample enrichment”.

How does this method work?

According to the card of the standard, ethyl acrylate, 2-ethylhexyl acrylate and methacrylic acid vapour is determined by gas chromatography with sample enrichment; the method is not used when compounds with the same retention time are present. The IMP procedures of 2014–2015 trap the acrylates on activated carbon, desorb them with carbon disulphide with added methanol or acetic acid and determine them with a flame ionisation detector.

What is the measuring range and accuracy?

STATUS (as of 18.11.2026): withdrawn 15-08-2014; card without "Replaced by" and "Replaces" fields; for ethyl acrylate current PN-Z-04570:2026-08 (GC-FID, 1 mg/m³ for 10 l); Edition (from the PKN card): PN-Z-04113-02:1978, Polish version; published 16-09-1978, 4 pages, KT 159 Chemical and Dust Hazards in the Working Environment, ICS 13.040.30; Substances and technique (from the card): ethyl acrylate, 2-ethylhexyl acrylate, methacrylic acid; gas chromatography with sample enrichment; the card gives no determinability; Limit values against which the result is assessed: ethyl acrylate (item 11): NDS 20 mg/m³, NDSCh 40 mg/m³, "skin"; 2-ethylhexyl acrylate (item 10): NDS 35 mg/m³, NDSCh 70 mg/m³, "skin"; methacrylic acid — not in the list (Journal of Laws 2026 item 447).

How long does the test take?

The procedure comprises 4 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.

What equipment is required?

Activated carbon tubes (100 mg/50 mg), Suction pump, Gas chromatograph with flame ionisation detector.

Where is this test used?

Measurements of ethyl acrylate and 2-ethylhexyl acrylate vapour in workplace air — assessment against NDS 20 / NDSCh 40 mg/m³ (item 11) and NDS 35 / NDSCh 70 mg/m³ (item 10) (Journal of Laws 2026 item 447); methacrylic acid — no value in the NDS list.

What safety precautions apply?

Work with the reference substances is carried out in an efficient laboratory fume hood, and used solutions are collected in containers intended for that purpose (IMP procedure 2015, point 4.3); The "skin" notation in the NDS list: the measurement in air does not cover absorption through the skin (ethyl acrylate, item 11; 2-ethylhexyl acrylate, item 10).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-Z-04113-02.

🔍 Find a laboratory performing this test