🌿 2-Methoxyethanol (2-methoxyethyl alcohol) in workplace air — adsorption on activated carbon, extraction and gas chromatography with sample enrichment, PN-Z-04167-02 (withdrawn standard)

Environment PN-Z-04167-02

In short

Determination of 2-methoxyethanol vapour (in the title of the standard: "alkohol 2-metoksyetylowy", 2-methoxyethyl alcohol) in workplace air: adsorption on activated carbon, extraction with a solution containing methyl alcohol and methylene chloride and gas chromatography. The test is performed according to PN-Z-04167-02:1986 (Polish version); STATUS (as of 18.11.2026): withdrawn 17-10-2011; card without "Replaced by" and "Replaces" fields; both standards of the PN-Z-04167 series withdrawn. The procedure comprises 5 steps; it is used for: Measurements of 2-methoxyethanol vapour in workplace air — assessment against the NDS of 3 mg/m³ (Journal of Laws 2026 item 447, item 364); the determinability of the standard (5 mg/m³) is higher than the NDS.

At a glance

  • Standard: PN-Z-04167-02:1986 (Polish version)
  • Category: Environment
  • Procedure steps: 5
  • STATUS (as of 18.11.2026): withdrawn 17-10-2011; card without "Replaced by" and "Replaces" fields; both standards of the PN-Z-04167 series withdrawn
  • Edition (from the PKN card): PN-Z-04167-02:1986, Polish version; published 30-06-1986, 3 pages, KT 159 Chemical and Dust Hazards in the Working Environment, ICS 13.040.30
  • Principle and determinability (from the card): adsorption of the vapour on activated carbon, extraction with a solution containing methyl alcohol and methylene chloride, gas chromatography; determinability 5 mg/m³

Overview

STATUS (as of 18.11.2026). The card of PN-Z-04167-02:1986 (Polish version) has the heading "Withdrawn": published 30-06-1986, withdrawal date 17-10-2011, 3 pages; there are no "Replaced by" or "Replaces" fields. PKN search (18.11.2026): the term "metoksyetylowego" returns two sheets of the series (01:1986 and 02:1986), both withdrawn; the systematic term "metoksyetanolu" returns no standard.

WHAT THE STANDARD COVERS. The scope from the PKN catalogue card, quoted in full: "The test method consists in the adsorption of 2-methoxyethyl alcohol vapour on activated carbon, its extraction with a solution of methyl alcohol methylene chloride and chromatographic analysis of the solution obtained. The determinability of the method is 5 mg in 1 cubic metre of air" (our translation; on the card a word is missing between "methyl alcohol" and "methylene chloride", and we do not supply it).

LIMIT VALUES AND THE REGULATION ON THE METHOD. The NDS list — Annex 1 to the regulation of 12 June 2018 as worded by the regulation of 26 March 2026 (Journal of Laws 2026 item 447), item 364 "2-Methoxyethanol" [109-86-4]: NDS (8-hour value) 3 mg/m³ (1 ppm), no NDSCh, "skin" notation. According to the explanatory note to the list, the "skin" notation means that "absorption of the substance through the skin may be as important as exposure by inhalation" (our translation). The determinability according to the card (5 mg/m³) is higher than the NDS — a result "below the determinability" does not decide whether the NDS is met. The method is addressed by § 16 of the regulation on tests and measurements of agents harmful to health in the working environment (consolidated text — Journal of Laws 2025 item 949): "Tests and measurements are performed in accordance with the methods specified in Polish Standards and, where there are no such standards, with methods recommended and validated by the laboratories referred to in § 15(1) and (2)(1)" (our translation). The provision does not name this standard; whether a standard withdrawn by PKN falls under the words "where there are no such standards" — WE DO NOT DECIDE.

PROCEDURE ACCORDING TO NEWER METHODS (second source; numbers of the procedures, not of the standard). Romanowicz, Gromiec, "2-Metoksyetanol – metoda oznaczania" (2-Methoxyethanol – determination method), Podstawy i Metody Oceny Środowiska Pracy 2010, no. 1(63), pp. 169–175 (Nofer Institute of Occupational Medicine, IMP): a tube with two sections of activated carbon (100 mg and 50 mg), up to 10 l of air at a flow rate not exceeding 6 l/h, according to PN-Z-04008-7; samples kept in a refrigerator are stable for 15 days; each section is desorbed with 1 ml of a solution of methylene chloride in methanol (95/5) for 30 min in an ultrasonic bath; chromatograph with a flame ionisation detector and a polar column; calibration curve 3–60 µg/ml; the amount in the shorter section should not exceed 10 % of the amount in the longer one; determinability 0.3 mg/m³ for 10 l. NIOSH Method 1403 "Alcohols IV" (issue 3, 15.03.2003) for 2-methoxyethanol: activated carbon 100 mg/50 mg, 0.01–0.05 l/min, 6–50 l, desorption with 1 ml of methylene chloride with methanol (95 : 5) in an ultrasonic bath, GC-FID. Both methods have a determinability different from that on the card of the standard — we do not transfer their numbers to the standard.

WHAT WE DO NOT GIVE HERE. We did not have the text of PN-Z-04167-02:1986 — PKN sells it (3 pages). We do not give the amount of activated carbon, air volume and flow rate, composition of the extraction solution, column, detector, chromatographic conditions or calculations according to the standard.

Method principle

According to the card of the standard, 2-methoxyethanol vapour from workplace air is adsorbed on activated carbon, extracted with a solution containing methyl alcohol and methylene chloride, and the solution is analysed chromatographically; the determinability is 5 mg/m³ — above the NDS. The IMP procedure of 2010 and NIOSH Method 1403 desorb the carbon with a solution of methylene chloride in methanol (95/5) and determine the compound with a flame ionisation detector. The result is compared with the NDS of 3 mg/m³ (NDS list of 2026, item 364).

Applications

Key parameters

ParameterValue
STATUS (as of 18.11.2026)withdrawn 17-10-2011; card without "Replaced by" and "Replaces" fields; both standards of the PN-Z-04167 series withdrawn
Edition (from the PKN card)PN-Z-04167-02:1986, Polish version; published 30-06-1986, 3 pages, KT 159 Chemical and Dust Hazards in the Working Environment, ICS 13.040.30
Principle and determinability (from the card)adsorption of the vapour on activated carbon, extraction with a solution containing methyl alcohol and methylene chloride, gas chromatography; determinability 5 mg/m³
Limit values against which the result is assessedNDS 3 mg/m³ (1 ppm), no NDSCh, "skin" notation — Journal of Laws 2026 item 447, item 364 "2-Methoxyethanol" [109-86-4]
IMP procedure 2010 (numbers of the procedure)activated carbon 100 mg/50 mg; up to 10 l, ≤ 6 l/h; desorption with 1 ml of methylene chloride in methanol (95/5), 30 min in an ultrasonic bath; GC-FID; 0.3 mg/m³ for 10 l

Standard

Standard number
PN-Z-04167-02:1986 (Polish version)
Title (PL)
Ochrona czystości powietrza — Badania zawartości alkoholu metoksyetylowego — Oznaczanie alkoholu 2-metoksyetylowego na stanowiskach pracy metodą chromatografii gazowej z wzbogacaniem próbki
Title (EN)
Air purity protection — Tests for methoxyethyl alcohol content — Determination of 2-methoxyethyl alcohol at workplaces by gas chromatography with sample enrichment

Step-by-step procedure

  1. Status of the document

    PKN card: standard withdrawn on 17-10-2011, no successor indicated (as of 18.11.2026).

  2. Sampling

    The vapour is adsorbed on activated carbon (from the card); in the IMP procedure 2010 — up to 10 l of air, ≤ 6 l/h.

  3. Extraction (desorption)

    Card: a solution containing methyl alcohol and methylene chloride; IMP procedure 2010 — 1 ml of methylene chloride in methanol (95/5), 30 min in an ultrasonic bath.

  4. Chromatographic analysis

    Gas chromatography (from the card); in the IMP procedure 2010 — flame ionisation detector, polar column.

  5. Result and assessment

    The concentration in mg/m³ is compared with the NDS of 3 mg/m³. With the determinability of the standard of 5 mg/m³, a result "below the determinability" does not decide whether the NDS is met. "Skin" notation: the measurement in air does not cover absorption through the skin.

Required equipment and apparatus

EquipmentExampleIndicative price
Activated carbon tubes (100 mg/50 mg)IMP procedure 2010 and NIOSH 1403; WE DO NOT GIVE the values according to the standard—
Suction pumpIMP procedure 2010: up to 10 l, ≤ 6 l/h; NIOSH 1403: 0.01–0.05 l/min—
Gas chromatograph with flame ionisation detectorIn both newer methods; WE DO NOT GIVE the detector according to the standard—
Ultrasonic bathDesorption for 30 min (IMP procedure 2010, NIOSH 1403)—

Reagents, media and consumables

ReagentCASDetails
Solution of methylene chloride in methanol (95/5)—Desorbent in the IMP procedure 2010 and NIOSH 1403 (1 ml); card of the standard: "solution of methyl alcohol methylene chloride" without composition
2-Methoxyethanol — reference substance109-86-4Working standard solutions of 3–60 µg/ml (IMP procedure 2010)

Health and safety (OHS)

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-Z-04167-02:1986 (Polish version) — “Air purity protection — Tests for methoxyethyl alcohol content — Determination of 2-methoxyethyl alcohol at workplaces by gas chromatography with sample enrichment”.

How does this method work?

According to the card of the standard, 2-methoxyethanol vapour from workplace air is adsorbed on activated carbon, extracted with a solution containing methyl alcohol and methylene chloride, and the solution is analysed chromatographically; the determinability is 5 mg/m³ — above the NDS. The IMP procedure of 2010 and NIOSH Method 1403 desorb the carbon with a solution of methylene chloride in methanol (95/5) and determine the compound with a flame ionisation detector.

What is the measuring range and accuracy?

STATUS (as of 18.11.2026): withdrawn 17-10-2011; card without "Replaced by" and "Replaces" fields; both standards of the PN-Z-04167 series withdrawn; Edition (from the PKN card): PN-Z-04167-02:1986, Polish version; published 30-06-1986, 3 pages, KT 159 Chemical and Dust Hazards in the Working Environment, ICS 13.040.30; Principle and determinability (from the card): adsorption of the vapour on activated carbon, extraction with a solution containing methyl alcohol and methylene chloride, gas chromatography; determinability 5 mg/m³; Limit values against which the result is assessed: NDS 3 mg/m³ (1 ppm), no NDSCh, "skin" notation — Journal of Laws 2026 item 447, item 364 "2-Methoxyethanol" [109-86-4].

How long does the test take?

The procedure comprises 5 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.

What equipment is required?

Activated carbon tubes (100 mg/50 mg), Suction pump, Gas chromatograph with flame ionisation detector, Ultrasonic bath.

Where is this test used?

Measurements of 2-methoxyethanol vapour in workplace air — assessment against the NDS of 3 mg/m³ (Journal of Laws 2026 item 447, item 364); the determinability of the standard (5 mg/m³) is higher than the NDS.

What safety precautions apply?

Methylene chloride is a carcinogen and methanol is very flammable (NIOSH 1403, "Special precautions"); work with the reference substances is carried out in an efficient laboratory fume hood (IMP procedure 2010, point 4.3); The "skin" notation in the NDS list: the measurement in air does not cover absorption through the skin (2-methoxyethanol, item 364).

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-Z-04167-02.

🔍 Find a laboratory performing this test