Union authorisation for the hydrogen peroxide disinfectant family ‘BPF_H2O2_AB’ — room disinfection efficacy demonstrated according to NF T 72-281, re-entry only below 1.25 mg/m³
The Official Journal of the EU of 24 November 2026 published Commission Implementing Regulation (EU) 2026/2594, which grants Applied Biocide GmbH Union authorisation No EU-0036534-0000 for the biocidal product family ‘BPF_H2O2_AB’ containing hydrogen peroxide (product-types 2, 3 and 4). The authorisation is valid from 14 December 2026 until 31 July 2032.
- Basis: the application was submitted to the European Chemicals Agency on 13 November 2025 as an application for the same product family as the related reference family ‘INTEROX Biocidal Product Family 1’ (authorisation EU-0027468-0000, Implementing Regulation (EU) 2022/1232). The Agency submitted its opinion on 4 February 2026: the differences are limited to information that can be the subject of an administrative change. The expiry date of the authorisation is aligned with that of the reference family.
- Composition and uses: hydrogen peroxide from 13 to 49.9 % (w/w), formulation types AL (any other liquid) and SL (soluble concentrate); the product characteristics include disinfection of surfaces of enclosed rooms by aerosol (13 %), disinfection of PET food packaging with vaporised hydrogen peroxide (VHP) and of aseptic packaging, disinfection of drinking water distribution and storage installations (up to 15 000 l, followed by thorough rinsing with drinking water), of surfaces in food and feed processing and of animal housing; professional users.
- Room disinfection: efficacy was demonstrated according to standard NF T 72-281 by nebulising 1 g of hydrogen peroxide per m³ of room volume in 22 min followed by 180 min contact time at room temperature; room volume 30–150 m³, median aerosol particle size below 0.5 μm. The user is to carry out a microbiological validation of the disinfection in the room concerned (or a ‘standard room’), and in addition to the biological validation — a chemical validation.
- Safety: re-entry into the room is only permitted once the air concentration has dropped below the reference value of 1.25 mg/m³; the ventilation time is determined by measurement with suitable measuring devices, and entry at a higher concentration only with protective equipment including a self-contained breathing apparatus (SCBA). For disinfection of drinking water installations a concentration of 13 % and contact times are given: bactericidal 10 min, yeasticidal and fungicidal 15 min, virucidal 30 min, sporicidal and all claimed organisms 60 min.