{"lab":{"_id":"6af574740ecd48de0c706243","country":"PL","accr_number":"AP 240","imported_at":"2026-11-11T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"Al. Tysiąclecia Państwa Polskiego 7, 25-314 Kielce","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"23.06.2026","city":"Kielce","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 %. Niepewność pomiaru dla CMC wyrażona jest w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w postaci równania Q[a; b] oznacza pierwiastek sumy kwadratów wyrazów w nawiasach: Q[a; b] = (a² + b²)^1/2.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The CMC uncertainty is expressed in measurand units. A CMC uncertainty value given as the equation Q[a; b] represents the square root of the sum of the squares of the terms in brackets: Q[a; b] = (a² + b²)^1/2.","cycle_from":"23.06.2026","cycle_to":"22.06.2030","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"6.01","pl":"długość","en":"length","de":"Länge","zh":"长度","cs":"délka"},{"codes":"6.02","pl":"kąt","en":"angle","de":"Winkel","zh":"角度","cs":"úhel"},{"codes":"6.03","pl":"długość (geometria powierzchni)","en":"length (surface geometry)","de":"Länge (Oberflächengeometrie)","zh":"长度（表面几何）","cs":"délka (geometrie povrchu)"}],"has_en":true,"has_zh":true,"issue":{"no":"1","date":"23.06.2026"},"issue_date":"23.06.2026","issue_number":"1","lab_division":"Laboratorium Zaawansowanych Technik Pomiarowych INTERLAB","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[20.6417749,50.8799721]},"map_coord":[50.8799721,20.6417749],"map_geo":"nominatim-street","methods_count":9,"name":"Politechnika Świętokrzyska","parse_date":"2026-11-11T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-11T12:00:00.000Z","pdf_files":["AP_240.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: długość, kąt, długość (geometria powierzchni). W stałej lokalizacji (S).","search_text":"politechnika świętokrzyska laboratorium zaawansowanych technik pomiarowych interlab al. tysiąclecia państwa polskiego 7, 25-314 kielce laboratorium wzorcujące. wielkości mierzone: długość, kąt, długość (geometria powierzchni). w stałej lokalizacji (s). ap 240 ap240 laboratorium wzorcujące wzorcowanie kalibracja length angle length (surface geometry) politechnika swietokrzyska laboratorium zaawansowanych technik pomiarowych interlab al. tysiaclecia panstwa polskiego 7, 25-314 kielce laboratorium wzorcujace. wielkosci mierzone: dlugosc, kat, dlugosc (geometria powierzchni). w stalej lokalizacji (s). ap 240 ap240 laboratorium wzorcujace wzorcowanie kalibracja length angle length (surface geometry)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20240,podmiot.html","source_pdf_sha256":"c2b779f861678fe2a19d49b1282d75e70b0050156f93ba33517140538f63f899","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/11/e15a7f86ea03dbaa0ebc222abf27c762/AP%20240.pdf","status":"active","updated_at":"2026-11-11T12:00:00.000Z","valid_from":"23-06-2026","valid_until":"22-06-2030","website":"","lab_division_en":"INTERLAB Advanced Measurement Techniques Laboratory","cmc_note_de":"Die von der CMC abgedeckte Messunsicherheit ist die erweiterte Unsicherheit bei einer Überdeckungswahrscheinlichkeit von ca. 95 %. Die CMC-Messunsicherheit ist in Einheiten der Messgröße angegeben. Ein als Gleichung Q[a; b] angegebener CMC-Unsicherheitswert bedeutet die Wurzel aus der Summe der Quadrate der Terme in Klammern: Q[a; b] = (a² + b²)^1/2.","has_de":true,"lab_division_de":"Labor für fortgeschrittene Messtechniken INTERLAB","cmc_note_zh":"CMC 测量不确定度为包含概率约 95 % 的扩展不确定度。CMC 测量不确定度以被测量的单位表示。以方程 Q[a; b] 表示的 CMC 测量不确定度值为括号内各项平方和的平方根：Q[a; b] = (a² + b²)^1/2。","lab_division_zh":"INTERLAB 先进测量技术实验室","cmc_note_cs":"Nejistota měření pro CMC je rozšířená nejistota při pravděpodobnosti pokrytí přibližně 95 %. Nejistota měření pro CMC je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření pro CMC vyjádřená rovnicí Q[a; b] znamená druhou odmocninu součtu čtverců členů v závorkách: Q[a; b] = (a² + b²)^1/2.","has_cs":true,"lab_division_cs":"Laboratoř pokročilých měřicích technik INTERLAB","pelny_cs":true},"methods":[{"_id":"69022c010242522fe4ba2ef0","lab_id":"6af574740ecd48de0c706243","country":"PL","accr_number":"AP 240","accr_body":"PCA","test_object":"Walce wewnętrzne","test_object_en":"Internal cylinders","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"100 mm do 1000 mm","cmc":"Q[4; 3 ·D] µm; D – wielkość mierzona (m)"}],"parameters_en":[{"name":"","range":"100 mm to 1000 mm","cmc":"Q[4; 3 ·D] µm; D – measured value (m)"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n100 mm do 1000 mm CMC Q[4; 3 ·D] µm; D – wielkość mierzona (m)\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW3_PL","norm_bases":["IW3_PL"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Walce wewnętrzne Wzorcowanie — Długość\n100 mm do 1000 mm CMC Q[4; 3 ·D] µm; D – wielkość mierzona (m)\nProcedura wewnętrzna; W stałej lokalizacji (S) IW3_PL Walce wewnetrzne Wzorcowanie — Dlugosc\n100 mm do 1000 mm CMC Q[4; 3 ·D] µm; D – wielkosc mierzona (m)\nProcedura wewnetrzna; W stalej lokalizacji (S) IW3_PL","search_en":"Internal cylinders Calibration — Length Internal procedure; At permanent location (S) Length Internal procedure At permanent location (S) IW3_PL","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"100 mm to 1000 mm","cmc":"Q[4; 3 ·D] µm; D – Messgröße (m)"}],"regulatory_area_de":"Länge","search_de":"Innenzylinder Kalibrierung — Länge Internes Verfahren; Am festen Standort (S) Länge Internes Verfahren Am festen Standort (S) IW3_PL","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Innenzylinder","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"100 mm to 1000 mm","cmc":"Q[4; 3 ·D] µm; D – 被测量 (m)"}],"regulatory_area_zh":"长度","search_zh":"内圆柱体 校准 — 长度 内部程序；在固定地点 (S) 长度 内部程序 在固定地点 (S) IW3_PL","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"内圆柱体","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"100 mm to 1000 mm","cmc":"Q[4; 3 ·D] µm; D – měřená veličina (m)"}],"regulatory_area_cs":"Délka","search_cs":"Vnitřní válce Kalibrace — Délka Vnitřní postup; Ve stálé lokalitě (S) Délka Vnitřní postup Ve stálé lokalitě (S) IW3_PL","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Vnitřní válce"},{"_id":"20f597c800e1749a9a6f7859","lab_id":"6af574740ecd48de0c706243","country":"PL","accr_number":"AP 240","accr_body":"PCA","test_object":"Dalmierze laserowe","test_object_en":"Laser distance meters","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"500 mm do 12000 mm","cmc":"0,7 mm"}],"parameters_en":[{"name":"","range":"500 mm to 12000 mm","cmc":"0,7 mm"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n500 mm do 12000 mm CMC 0,7 mm\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW1_PG","norm_bases":["IW1_PG"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Dalmierze laserowe Wzorcowanie — Długość\n500 mm do 12000 mm CMC 0,7 mm\nProcedura wewnętrzna; W stałej lokalizacji (S) IW1_PG Dalmierze laserowe Wzorcowanie — Dlugosc\n500 mm do 12000 mm CMC 0,7 mm\nProcedura wewnetrzna; W stalej lokalizacji (S) IW1_PG","search_en":"Laser distance meters Calibration — Length Internal procedure; At permanent location (S) Length Internal procedure At permanent location (S) IW1_PG","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"500 mm to 12000 mm","cmc":"0,7 mm"}],"regulatory_area_de":"Länge","search_de":"Laserentfernungsmesser Kalibrierung — Länge Internes Verfahren; Am festen Standort (S) Länge Internes Verfahren Am festen Standort (S) IW1_PG","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Laserentfernungsmesser","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"500 mm to 12000 mm","cmc":"0,7 mm"}],"regulatory_area_zh":"长度","search_zh":"激光测距仪 校准 — 长度 内部程序；在固定地点 (S) 长度 内部程序 在固定地点 (S) IW1_PG","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"激光测距仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"500 mm to 12000 mm","cmc":"0,7 mm"}],"regulatory_area_cs":"Délka","search_cs":"Laserové dálkoměry Kalibrace — Délka Vnitřní postup; Ve stálé lokalitě (S) Délka Vnitřní postup Ve stálé lokalitě (S) IW1_PG","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Laserové dálkoměry"},{"_id":"70ad847b3c3beb1ce0634410","lab_id":"6af574740ecd48de0c706243","country":"PL","accr_number":"AP 240","accr_body":"PCA","test_object":"Tachimetry","test_object_en":"Total stations","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"500 mm do 12000 mm","cmc":"0,3 mm"}],"parameters_en":[{"name":"","range":"500 mm to 12000 mm","cmc":"0,3 mm"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n500 mm do 12000 mm CMC 0,3 mm\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW1_PG","norm_bases":["IW1_PG"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Tachimetry Wzorcowanie — Długość\n500 mm do 12000 mm CMC 0,3 mm\nProcedura wewnętrzna; W stałej lokalizacji (S) IW1_PG Tachimetry Wzorcowanie — Dlugosc\n500 mm do 12000 mm CMC 0,3 mm\nProcedura wewnetrzna; W stalej lokalizacji (S) IW1_PG","search_en":"Total stations Calibration — Length Internal procedure; At permanent location (S) Length Internal procedure At permanent location (S) IW1_PG","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"500 mm to 12000 mm","cmc":"0,3 mm"}],"regulatory_area_de":"Länge","search_de":"Tachymeter Kalibrierung — Länge Internes Verfahren; Am festen Standort (S) Länge Internes Verfahren Am festen Standort (S) IW1_PG","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Tachymeter","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"500 mm to 12000 mm","cmc":"0,3 mm"}],"regulatory_area_zh":"长度","search_zh":"全站仪 校准 — 长度 内部程序；在固定地点 (S) 长度 内部程序 在固定地点 (S) IW1_PG","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"全站仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"500 mm to 12000 mm","cmc":"0,3 mm"}],"regulatory_area_cs":"Délka","search_cs":"Totální stanice Kalibrace — Délka Vnitřní postup; Ve stálé lokalitě (S) Délka Vnitřní postup Ve stálé lokalitě (S) IW1_PG","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Totální stanice"},{"_id":"01d375e423f889327fa2f4ca","lab_id":"6af574740ecd48de0c706243","country":"PL","accr_number":"AP 240","accr_body":"PCA","test_object":"Kątowniki 90° dwuramienne","test_object_en":"90° two-arm squares","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"do 1000 mm","cmc":"1,0”"}],"parameters_en":[{"name":"","range":"up to 1000 mm","cmc":"1,0”"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\ndo 1000 mm CMC 1,0”\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW2_PL","norm_bases":["IW2_PL"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątowniki 90° dwuramienne Wzorcowanie — Kąt\ndo 1000 mm CMC 1,0”\nProcedura wewnętrzna; W stałej lokalizacji (S) IW2_PL Katowniki 90° dwuramienne Wzorcowanie — Kat\ndo 1000 mm CMC 1,0”\nProcedura wewnetrzna; W stalej lokalizacji (S) IW2_PL","search_en":"90° two-arm squares Calibration — Angle Internal procedure; At permanent location (S) Angle Internal procedure At permanent location (S) IW2_PL","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"bis 1000 mm","cmc":"1,0”"}],"regulatory_area_de":"Winkel","search_de":"Zweischenklige 90°-Anschlagwinkel Kalibrierung — Winkel Internes Verfahren; Am festen Standort (S) Winkel Internes Verfahren Am festen Standort (S) IW2_PL","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Zweischenklige 90°-Anschlagwinkel","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"至 1000 mm","cmc":"1,0”"}],"regulatory_area_zh":"角度","search_zh":"90° 宽座直角尺 校准 — 角度 内部程序；在固定地点 (S) 角度 内部程序 在固定地点 (S) IW2_PL","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"90° 宽座直角尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"do 1000 mm","cmc":"1,0”"}],"regulatory_area_cs":"Úhel","search_cs":"Dvouramenné úhelníky 90° Kalibrace — Úhel Vnitřní postup; Ve stálé lokalitě (S) Úhel Vnitřní postup Ve stálé lokalitě (S) IW2_PL","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Dvouramenné úhelníky 90°"},{"_id":"85800875f2e517895eed93ee","lab_id":"6af574740ecd48de0c706243","country":"PL","accr_number":"AP 240","accr_body":"PCA","test_object":"Wzorce chropowatości typu A","test_object_en":"Roughness measurement standards type A","methodology":"Wzorcowanie — Długość (geometria powierzchni)","methodology_en":"Calibration — Length (surface geometry)","parameters":[{"name":"Pt","range":"0,1 µm do 15 µm","cmc":"60 nm"}],"parameters_en":[{"name":"Pt","range":"0,1 µm to 15 µm","cmc":"60 nm"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (geometria powierzchni)\nPt 0,1 µm do 15 µm CMC 60 nm\nW stałej lokalizacji (S)","reference":"PN-EN ISO 5436-1:2002","norm_bases":["PN-EN ISO 5436-1:2002"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (geometria powierzchni)","regulatory_area_en":"Length (surface geometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce chropowatości typu A Wzorcowanie — Długość (geometria powierzchni)\nPt 0,1 µm do 15 µm CMC 60 nm\nW stałej lokalizacji (S) PN-EN ISO 5436-1:2002 Wzorce chropowatosci typu A Wzorcowanie — Dlugosc (geometria powierzchni)\nPt 0,1 µm do 15 µm CMC 60 nm\nW stalej lokalizacji (S) PN-EN ISO 5436-1:2002","search_en":"Roughness measurement standards type A Calibration — Length (surface geometry) At permanent location (S) Length (surface geometry) At permanent location (S) Pt PN-EN ISO 5436-1:2002","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Oberflächengeometrie)","parameters_de":[{"name":"Pt","range":"0,1 µm to 15 µm","cmc":"60 nm"}],"regulatory_area_de":"Länge (Oberflächengeometrie)","search_de":"Rauheitsnormale Typ A Kalibrierung — Länge (Oberflächengeometrie) Am festen Standort (S) Länge (Oberflächengeometrie) Am festen Standort (S) Pt PN-EN ISO 5436-1:2002","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Rauheitsnormale Typ A","methodology_zh":"校准 — 长度（表面几何）","parameters_zh":[{"name":"Pt","range":"0,1 µm to 15 µm","cmc":"60 nm"}],"regulatory_area_zh":"长度（表面几何）","search_zh":"A 型粗糙度标准器 校准 — 长度（表面几何） 在固定地点 (S) 长度（表面几何） 在固定地点 (S) Pt PN-EN ISO 5436-1:2002","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"A 型粗糙度标准器","methodology_cs":"Kalibrace — Délka (geometrie povrchu)","parameters_cs":[{"name":"Pt","range":"0,1 µm to 15 µm","cmc":"60 nm"}],"regulatory_area_cs":"Délka (geometrie povrchu)","search_cs":"Etalony drsnosti typu A Kalibrace — Délka (geometrie povrchu) Ve stálé lokalitě (S) Délka (geometrie povrchu) Ve stálé lokalitě (S) Pt PN-EN ISO 5436-1:2002","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Etalony drsnosti typu A"},{"_id":"7d54907511a80be84e6a6cb8","lab_id":"6af574740ecd48de0c706243","country":"PL","accr_number":"AP 240","accr_body":"PCA","test_object":"Wzorce chropowatości typu B1","test_object_en":"Roughness measurement standards type B1","methodology":"Wzorcowanie — Długość (geometria powierzchni)","methodology_en":"Calibration — Length (surface geometry)","parameters":[{"name":"Ra","range":"0, 5 µm do 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – wielkość mierzona (µm)"}],"parameters_en":[{"name":"Ra","range":"0, 5 µm to 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – measured value (µm)"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (geometria powierzchni)\nRa 0, 5 µm do 15 µm CMC Q[15; 25 · Ra] nm; Ra – wielkość mierzona (µm)\nW stałej lokalizacji (S)","reference":"PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","norm_bases":["PN-EN ISO 21920-2:2022-06","PN-EN ISO 21920-3:2022-06"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (geometria powierzchni)","regulatory_area_en":"Length (surface geometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce chropowatości typu B1 Wzorcowanie — Długość (geometria powierzchni)\nRa 0, 5 µm do 15 µm CMC Q[15; 25 · Ra] nm; Ra – wielkość mierzona (µm)\nW stałej lokalizacji (S) PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06 Wzorce chropowatosci typu B1 Wzorcowanie — Dlugosc (geometria powierzchni)\nRa 0, 5 µm do 15 µm CMC Q[15; 25 · Ra] nm; Ra – wielkosc mierzona (µm)\nW stalej lokalizacji (S) PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","search_en":"Roughness measurement standards type B1 Calibration — Length (surface geometry) At permanent location (S) Length (surface geometry) At permanent location (S) Ra PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Oberflächengeometrie)","parameters_de":[{"name":"Ra","range":"0, 5 µm to 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – Messgröße (µm)"}],"regulatory_area_de":"Länge (Oberflächengeometrie)","search_de":"Rauheitsnormale Typ B1 Kalibrierung — Länge (Oberflächengeometrie) Am festen Standort (S) Länge (Oberflächengeometrie) Am festen Standort (S) Ra PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Rauheitsnormale Typ B1","methodology_zh":"校准 — 长度（表面几何）","parameters_zh":[{"name":"Ra","range":"0, 5 µm to 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – 被测量 (µm)"}],"regulatory_area_zh":"长度（表面几何）","search_zh":"B1 型粗糙度标准器 校准 — 长度（表面几何） 在固定地点 (S) 长度（表面几何） 在固定地点 (S) Ra PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"B1 型粗糙度标准器","methodology_cs":"Kalibrace — Délka (geometrie povrchu)","parameters_cs":[{"name":"Ra","range":"0, 5 µm to 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – měřená veličina (µm)"}],"regulatory_area_cs":"Délka (geometrie povrchu)","search_cs":"Etalony drsnosti typu B1 Kalibrace — Délka (geometrie povrchu) Ve stálé lokalitě (S) Délka (geometrie povrchu) Ve stálé lokalitě (S) Ra PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Etalony drsnosti typu B1"},{"_id":"f779ab669c648089eb6486e8","lab_id":"6af574740ecd48de0c706243","country":"PL","accr_number":"AP 240","accr_body":"PCA","test_object":"Wzorce chropowatości typu C","test_object_en":"Roughness measurement standards type C","methodology":"Wzorcowanie — Długość (geometria powierzchni)","methodology_en":"Calibration — Length (surface geometry)","parameters":[{"name":"Ra, Rq","range":"0,05 µm do 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – wielkość mierzona (µm)"},{"name":"Rz, Rt, Rp, Rv","range":"do 1000 µm","cmc":"[40; 50 · Rp] nm; Rp – wielkość mierzona (µm)"}],"parameters_en":[{"name":"Ra, Rq","range":"0,05 µm to 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – measured value (µm)"},{"name":"Rz, Rt, Rp, Rv","range":"up to 1000 µm","cmc":"[40; 50 · Rp] nm; Rp – measured value (µm)"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (geometria powierzchni)\nZakres:\nRa, Rq 0,05 µm do 15 µm CMC Q[15; 25 · Ra] nm; Ra – wielkość mierzona (µm)\nRz, Rt, Rp, Rv do 1000 µm CMC [40; 50 · Rp] nm; Rp – wielkość mierzona (µm)\nW stałej lokalizacji (S)","reference":"PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","norm_bases":["PN-EN ISO 21920-2:2022-06","PN-EN ISO 21920-3:2022-06"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (geometria powierzchni)","regulatory_area_en":"Length (surface geometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce chropowatości typu C Wzorcowanie — Długość (geometria powierzchni)\nZakres:\nRa, Rq 0,05 µm do 15 µm CMC Q[15; 25 · Ra] nm; Ra – wielkość mierzona (µm)\nRz, Rt, Rp, Rv do 1000 µm CMC [40; 50 · Rp] nm; Rp – wielkość mierzona (µm)\nW stałej lokalizacji (S) PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06 Wzorce chropowatosci typu C Wzorcowanie — Dlugosc (geometria powierzchni)\nZakres:\nRa, Rq 0,05 µm do 15 µm CMC Q[15; 25 · Ra] nm; Ra – wielkosc mierzona (µm)\nRz, Rt, Rp, Rv do 1000 µm CMC [40; 50 · Rp] nm; Rp – wielkosc mierzona (µm)\nW stalej lokalizacji (S) PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","search_en":"Roughness measurement standards type C Calibration — Length (surface geometry) At permanent location (S) Length (surface geometry) At permanent location (S) Ra, Rq Rz, Rt, Rp, Rv PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Oberflächengeometrie)","parameters_de":[{"name":"Ra, Rq","range":"0,05 µm to 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – Messgröße (µm)"},{"name":"Rz, Rt, Rp, Rv","range":"up to 1000 µm","cmc":"[40; 50 · Rp] nm; Rp – Messgröße (µm)"}],"regulatory_area_de":"Länge (Oberflächengeometrie)","search_de":"Rauheitsnormale Typ C Kalibrierung — Länge (Oberflächengeometrie) Am festen Standort (S) Länge (Oberflächengeometrie) Am festen Standort (S) Ra, Rq Rz, Rt, Rp, Rv PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Rauheitsnormale Typ C","methodology_zh":"校准 — 长度（表面几何）","parameters_zh":[{"name":"Ra, Rq","range":"0,05 µm to 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – 被测量 (µm)"},{"name":"Rz, Rt, Rp, Rv","range":"up to 1000 µm","cmc":"[40; 50 · Rp] nm; Rp – 被测量 (µm)"}],"regulatory_area_zh":"长度（表面几何）","search_zh":"C 型粗糙度标准器 校准 — 长度（表面几何） 在固定地点 (S) 长度（表面几何） 在固定地点 (S) Ra, Rq Rz, Rt, Rp, Rv PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"C 型粗糙度标准器","methodology_cs":"Kalibrace — Délka (geometrie povrchu)","parameters_cs":[{"name":"Ra, Rq","range":"0,05 µm to 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – měřená veličina (µm)"},{"name":"Rz, Rt, Rp, Rv","range":"up to 1000 µm","cmc":"[40; 50 · Rp] nm; Rp – měřená veličina (µm)"}],"regulatory_area_cs":"Délka (geometrie povrchu)","search_cs":"Etalony drsnosti typu C Kalibrace — Délka (geometrie povrchu) Ve stálé lokalitě (S) Délka (geometrie povrchu) Ve stálé lokalitě (S) Ra, Rq Rz, Rt, Rp, Rv PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Etalony drsnosti typu C"},{"_id":"98feace3c6cc62b5fa03d97b","lab_id":"6af574740ecd48de0c706243","country":"PL","accr_number":"AP 240","accr_body":"PCA","test_object":"Wzorce chropowatości typu D","test_object_en":"Roughness measurement standards type D","methodology":"Wzorcowanie — Długość (geometria powierzchni)","methodology_en":"Calibration — Length (surface geometry)","parameters":[{"name":"Ra, Rq","range":"0,05 µm do 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – wielkość mierzona (µm)"},{"name":"Rz, Rt, Rp, Rv, Rmax","range":"do 1000 µm","cmc":"[40; 60 · Rp] nm; Rp – wielkość mierzona (µm)"}],"parameters_en":[{"name":"Ra, Rq","range":"0,05 µm to 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – measured value (µm)"},{"name":"Rz, Rt, Rp, Rv, Rmax","range":"up to 1000 µm","cmc":"[40; 60 · Rp] nm; Rp – measured value (µm)"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (geometria powierzchni)\nZakres:\nRa, Rq 0,05 µm do 15 µm CMC Q[15; 25 · Ra] nm; Ra – wielkość mierzona (µm)\nRz, Rt, Rp, Rv, Rmax do 1000 µm CMC [40; 60 · Rp] nm; Rp – wielkość mierzona (µm)\nW stałej lokalizacji (S)","reference":"PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","norm_bases":["PN-EN ISO 21920-2:2022-06","PN-EN ISO 21920-3:2022-06"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (geometria powierzchni)","regulatory_area_en":"Length (surface geometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce chropowatości typu D Wzorcowanie — Długość (geometria powierzchni)\nZakres:\nRa, Rq 0,05 µm do 15 µm CMC Q[15; 25 · Ra] nm; Ra – wielkość mierzona (µm)\nRz, Rt, Rp, Rv, Rmax do 1000 µm CMC [40; 60 · Rp] nm; Rp – wielkość mierzona (µm)\nW stałej lokalizacji (S) PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06 Wzorce chropowatosci typu D Wzorcowanie — Dlugosc (geometria powierzchni)\nZakres:\nRa, Rq 0,05 µm do 15 µm CMC Q[15; 25 · Ra] nm; Ra – wielkosc mierzona (µm)\nRz, Rt, Rp, Rv, Rmax do 1000 µm CMC [40; 60 · Rp] nm; Rp – wielkosc mierzona (µm)\nW stalej lokalizacji (S) PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","search_en":"Roughness measurement standards type D Calibration — Length (surface geometry) At permanent location (S) Length (surface geometry) At permanent location (S) Ra, Rq Rz, Rt, Rp, Rv, Rmax PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Oberflächengeometrie)","parameters_de":[{"name":"Ra, Rq","range":"0,05 µm to 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – Messgröße (µm)"},{"name":"Rz, Rt, Rp, Rv, Rmax","range":"up to 1000 µm","cmc":"[40; 60 · Rp] nm; Rp – Messgröße (µm)"}],"regulatory_area_de":"Länge (Oberflächengeometrie)","search_de":"Rauheitsnormale Typ D Kalibrierung — Länge (Oberflächengeometrie) Am festen Standort (S) Länge (Oberflächengeometrie) Am festen Standort (S) Ra, Rq Rz, Rt, Rp, Rv, Rmax PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Rauheitsnormale Typ D","methodology_zh":"校准 — 长度（表面几何）","parameters_zh":[{"name":"Ra, Rq","range":"0,05 µm to 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – 被测量 (µm)"},{"name":"Rz, Rt, Rp, Rv, Rmax","range":"up to 1000 µm","cmc":"[40; 60 · Rp] nm; Rp – 被测量 (µm)"}],"regulatory_area_zh":"长度（表面几何）","search_zh":"D 型粗糙度标准器 校准 — 长度（表面几何） 在固定地点 (S) 长度（表面几何） 在固定地点 (S) Ra, Rq Rz, Rt, Rp, Rv, Rmax PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"D 型粗糙度标准器","methodology_cs":"Kalibrace — Délka (geometrie povrchu)","parameters_cs":[{"name":"Ra, Rq","range":"0,05 µm to 15 µm","cmc":"Q[15; 25 · Ra] nm; Ra – měřená veličina (µm)"},{"name":"Rz, Rt, Rp, Rv, Rmax","range":"up to 1000 µm","cmc":"[40; 60 · Rp] nm; Rp – měřená veličina (µm)"}],"regulatory_area_cs":"Délka (geometrie povrchu)","search_cs":"Etalony drsnosti typu D Kalibrace — Délka (geometrie povrchu) Ve stálé lokalitě (S) Délka (geometrie povrchu) Ve stálé lokalitě (S) Ra, Rq Rz, Rt, Rp, Rv, Rmax PN-EN ISO 21920-2:2022-06 PN-EN ISO 21920-3:2022-06","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Etalony drsnosti typu D"},{"_id":"18abe11fa942007288819695","lab_id":"6af574740ecd48de0c706243","country":"PL","accr_number":"AP 240","accr_body":"PCA","test_object":"Wzorce powiększenia","test_object_en":"Magnification standards","methodology":"Wzorcowanie — Długość (geometria powierzchni)","methodology_en":"Calibration — Length (surface geometry)","parameters":[{"name":"Pt","range":"do 15 µm","cmc":"200 nm"}],"parameters_en":[{"name":"Pt","range":"up to 15 µm","cmc":"200 nm"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (geometria powierzchni)\nPt do 15 µm CMC 200 nm\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW1_PL","norm_bases":["IW1_PL"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (geometria powierzchni)","regulatory_area_en":"Length (surface geometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce powiększenia Wzorcowanie — Długość (geometria powierzchni)\nPt do 15 µm CMC 200 nm\nProcedura wewnętrzna; W stałej lokalizacji (S) IW1_PL Wzorce powiekszenia Wzorcowanie — Dlugosc (geometria powierzchni)\nPt do 15 µm CMC 200 nm\nProcedura wewnetrzna; W stalej lokalizacji (S) IW1_PL","search_en":"Magnification standards Calibration — Length (surface geometry) Internal procedure; At permanent location (S) Length (surface geometry) Internal procedure At permanent location (S) Pt IW1_PL","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Oberflächengeometrie)","parameters_de":[{"name":"Pt","range":"up to 15 µm","cmc":"200 nm"}],"regulatory_area_de":"Länge (Oberflächengeometrie)","search_de":"Vergrößerungsnormale Kalibrierung — Länge (Oberflächengeometrie) Internes Verfahren; Am festen Standort (S) Länge (Oberflächengeometrie) Internes Verfahren Am festen Standort (S) Pt IW1_PL","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Vergrößerungsnormale","methodology_zh":"校准 — 长度（表面几何）","parameters_zh":[{"name":"Pt","range":"up to 15 µm","cmc":"200 nm"}],"regulatory_area_zh":"长度（表面几何）","search_zh":"放大倍率标准器 校准 — 长度（表面几何） 内部程序；在固定地点 (S) 长度（表面几何） 内部程序 在固定地点 (S) Pt IW1_PL","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"放大倍率标准器","methodology_cs":"Kalibrace — Délka (geometrie povrchu)","parameters_cs":[{"name":"Pt","range":"up to 15 µm","cmc":"200 nm"}],"regulatory_area_cs":"Délka (geometrie povrchu)","search_cs":"Etalony zvětšení Kalibrace — Délka (geometrie povrchu) Vnitřní postup; Ve stálé lokalitě (S) Délka (geometrie povrchu) Vnitřní postup Ve stálé lokalitě (S) Pt IW1_PL","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Etalony zvětšení"}],"has_pdf":true}