{"lab":{"_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","imported_at":"2026-11-13T12:00:00.000Z","accr_body":"PCA","activity_conducted":"poza stałą lokalizacją (P)","activity_conducted_en":"outside of permanent location (P)","address":"ul. Os. Pod Grapą 6/3, 34-300 Żywiec","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"02.02.2026","city":"Żywiec","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 %. Niepewność pomiaru dla CMC wyrażona jest w jednostkach wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The CMC uncertainty is expressed in measurand units.","cycle_from":"02.02.2026","cycle_to":"01.02.2030","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"6.01","pl":"długość","en":"length","de":"Länge","zh":"长度","cs":"délka"},{"codes":"6.02","pl":"kąt","en":"angle","de":"Winkel","zh":"角度","cs":"úhel"},{"codes":"6.04","pl":"długość (pomiary współrzędnościowe)","en":"length (coordinate measurements)","de":"Länge (Koordinatenmesstechnik)","zh":"长度（坐标测量）","cs":"délka (souřadnicová měření)"}],"has_en":true,"has_zh":true,"issue":{"no":"1","date":"02.02.2026"},"issue_date":"02.02.2026","issue_number":"1","lab_division":null,"lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[19.2165672,49.6805617]},"map_coord":[49.6805617,19.2165672],"map_geo":"nominatim-street","methods_count":14,"name":"Lab-WP Wojciech Płowucha","parse_date":"2026-11-13T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-13T12:00:00.000Z","pdf_files":["AP_236.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: długość, kąt, długość (pomiary współrzędnościowe). Poza stałą lokalizacją (P).","search_text":"lab-wp wojciech płowucha ul. os. pod grapą 6/3, 34-300 żywiec laboratorium wzorcujące. wielkości mierzone: długość, kąt, długość (pomiary współrzędnościowe). poza stałą lokalizacją (p). ap 236 ap236 laboratorium wzorcujące wzorcowanie kalibracja length angle length (coordinate measurements) lab-wp wojciech plowucha ul. os. pod grapa 6/3, 34-300 zywiec laboratorium wzorcujace. wielkosci mierzone: dlugosc, kat, dlugosc (pomiary wspolrzednosciowe). poza stala lokalizacja (p). ap 236 ap236 laboratorium wzorcujace wzorcowanie kalibracja length angle length (coordinate measurements)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20236,podmiot.html","source_pdf_sha256":"fe5d77b3d65c516cdb0e0ec1dacd5d0fb573ce469012f03e92ec6288948b34e5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/13/d2695c92f9d7cc39f2f565bbf8555146/AP%20236.pdf","status":"active","updated_at":"2026-11-13T12:00:00.000Z","valid_from":"02-02-2026","valid_until":"01-02-2030","website":"www.lab-wp.pl","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 %. Die Messunsicherheit der CMC wird in Einheiten der Messgröße angegeben.","has_de":true,"cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度。CMC测量不确定度以被测量的单位表示。","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 %. Nejistota měření CMC je vyjádřena v jednotkách měřené veličiny.","has_cs":true,"pelny_cs":true},"methods":[{"_id":"0ca6d7cf38eabbe68f0b65f4","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Długościomierze pionowe Abbego","test_object_en":"Vertical Abbe length measuring machines","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 100 mm","cmc":"(0,1 + 2 · L) µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"(0,1 + 2 · L) µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 100 mm CMC (0,1 + 2 · L) µm\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"PWZ-1","norm_bases":["PWZ-1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":true,"location_of_activity":"P","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Długościomierze pionowe Abbego Wzorcowanie — Długość\n0 mm do 100 mm CMC (0,1 + 2 · L) µm\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) PWZ-1 Dlugosciomierze pionowe Abbego Wzorcowanie — Dlugosc\n0 mm do 100 mm CMC (0,1 + 2 · L) µm\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) PWZ-1","search_en":"Vertical Abbe length measuring machines Calibration — Length Internal procedure; Direct method; Outside of permanent location (P) Length Internal procedure Direct method Outside of permanent location (P) PWZ-1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 100 mm","cmc":"(0,1 + 2 · L) µm"}],"regulatory_area_de":"Länge","search_de":"Vertikale Abbe-Längenmessgeräte Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Länge Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) PWZ-1","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Vertikale Abbe-Längenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 100 mm","cmc":"(0,1 + 2 · L) µm"}],"regulatory_area_zh":"长度","search_zh":"立式阿贝测长仪 校准 — 长度 内部程序；直接法；固定地点以外 (P) 长度 内部程序 直接法 固定地点以外 (P) PWZ-1","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"立式阿贝测长仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 100 mm","cmc":"(0,1 + 2 · L) µm"}],"regulatory_area_cs":"Délka","search_cs":"Vertikální Abbeovy délkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Délka Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) PWZ-1","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Vertikální Abbeovy délkoměry"},{"_id":"130726f74a81556a6950431f","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Długościomierze poziome Abbego","test_object_en":"Horizontal Abbe length measuring machines","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 1000 mm","cmc":"(0,1 + 2 · L) µm"}],"parameters_en":[{"name":"","range":"0 mm to 1000 mm","cmc":"(0,1 + 2 · L) µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 1000 mm CMC (0,1 + 2 · L) µm\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"PWZ-1","norm_bases":["PWZ-1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":true,"location_of_activity":"P","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Długościomierze poziome Abbego Wzorcowanie — Długość\n0 mm do 1000 mm CMC (0,1 + 2 · L) µm\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) PWZ-1 Dlugosciomierze poziome Abbego Wzorcowanie — Dlugosc\n0 mm do 1000 mm CMC (0,1 + 2 · L) µm\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) PWZ-1","search_en":"Horizontal Abbe length measuring machines Calibration — Length Internal procedure; Direct method; Outside of permanent location (P) Length Internal procedure Direct method Outside of permanent location (P) PWZ-1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 1000 mm","cmc":"(0,1 + 2 · L) µm"}],"regulatory_area_de":"Länge","search_de":"Horizontale Abbe-Längenmessgeräte Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Länge Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) PWZ-1","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Horizontale Abbe-Längenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"(0,1 + 2 · L) µm"}],"regulatory_area_zh":"长度","search_zh":"卧式阿贝测长仪 校准 — 长度 内部程序；直接法；固定地点以外 (P) 长度 内部程序 直接法 固定地点以外 (P) PWZ-1","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"卧式阿贝测长仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 1000 mm","cmc":"(0,1 + 2 · L) µm"}],"regulatory_area_cs":"Délka","search_cs":"Horizontální Abbeovy délkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Délka Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) PWZ-1","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Horizontální Abbeovy délkoměry"},{"_id":"49a6014e34ecbe14cfe53323","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Długościomierze poziome (maszyny 1-D)","test_object_en":"Horizontal length measuring machines (1-D machines)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 1000 mm","cmc":"(0,1 + 2 · L) µm"},{"name":"","range":"1000 mm do 1900 mm","cmc":"(0,4 + 2 · L) µm"},{"name":"","range":"1900 mm do 2700 mm","cmc":"(0,6 + 2 · L) µm"}],"parameters_en":[{"name":"","range":"0 mm to 1000 mm","cmc":"(0,1 + 2 · L) µm"},{"name":"","range":"1000 mm do 1900 mm","cmc":"(0,4 + 2 · L) µm"},{"name":"","range":"1900 mm do 2700 mm","cmc":"(0,6 + 2 · L) µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 1000 mm CMC (0,1 + 2 · L) µm\n1000 mm do 1900 mm CMC (0,4 + 2 · L) µm\n1900 mm do 2700 mm CMC (0,6 + 2 · L) µm\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"PWZ-1","norm_bases":["PWZ-1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":true,"location_of_activity":"P","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Długościomierze poziome (maszyny 1-D) Wzorcowanie — Długość\nZakres:\n0 mm do 1000 mm CMC (0,1 + 2 · L) µm\n1000 mm do 1900 mm CMC (0,4 + 2 · L) µm\n1900 mm do 2700 mm CMC (0,6 + 2 · L) µm\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) PWZ-1 Dlugosciomierze poziome (maszyny 1-D) Wzorcowanie — Dlugosc\nZakres:\n0 mm do 1000 mm CMC (0,1 + 2 · L) µm\n1000 mm do 1900 mm CMC (0,4 + 2 · L) µm\n1900 mm do 2700 mm CMC (0,6 + 2 · L) µm\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) PWZ-1","search_en":"Horizontal length measuring machines (1-D machines) Calibration — Length Internal procedure; Direct method; Outside of permanent location (P) Length Internal procedure Direct method Outside of permanent location (P) PWZ-1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 1000 mm","cmc":"(0,1 + 2 · L) µm"},{"name":"","range":"1000 mm do 1900 mm","cmc":"(0,4 + 2 · L) µm"},{"name":"","range":"1900 mm do 2700 mm","cmc":"(0,6 + 2 · L) µm"}],"regulatory_area_de":"Länge","search_de":"Horizontale Längenmessgeräte (1-D-Maschinen) Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Länge Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) PWZ-1","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Horizontale Längenmessgeräte (1-D-Maschinen)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"(0,1 + 2 · L) µm"},{"name":"","range":"1000 mm do 1900 mm","cmc":"(0,4 + 2 · L) µm"},{"name":"","range":"1900 mm do 2700 mm","cmc":"(0,6 + 2 · L) µm"}],"regulatory_area_zh":"长度","search_zh":"卧式测长仪（一维测量机） 校准 — 长度 内部程序；直接法；固定地点以外 (P) 长度 内部程序 直接法 固定地点以外 (P) PWZ-1","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"卧式测长仪（一维测量机）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 1000 mm","cmc":"(0,1 + 2 · L) µm"},{"name":"","range":"1000 mm do 1900 mm","cmc":"(0,4 + 2 · L) µm"},{"name":"","range":"1900 mm do 2700 mm","cmc":"(0,6 + 2 · L) µm"}],"regulatory_area_cs":"Délka","search_cs":"Horizontální délkoměry (1-D stroje) Kalibrace — Délka Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Délka Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) PWZ-1","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Horizontální délkoměry (1-D stroje)"},{"_id":"556c413981ac2c1aa655a37d","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Mikroskopy pomiarowe uniwersalne\nMikroskopy pomiarowe warsztatowe","test_object_en":"Universal measuring microscopes\nWorkshop measuring microscopes","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 25 mm","cmc":"(0,35 + L) µm"},{"name":"","range":"25 mm do 500 mm","cmc":"(0,4 + 2,5 · L) µm"},{"name":"","range":"500 mm do 1000 mm","cmc":"(0,5 + 3 · L) µm"},{"name":"","range":"1000 mm do 1500 mm","cmc":"(0,7 + 3 · L) µm"},{"name":"","range":"1500 mm do 2000 mm","cmc":"(0,9 + 3 · L) µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"(0,35 + L) µm"},{"name":"","range":"25 mm do 500 mm","cmc":"(0,4 + 2,5 · L) µm"},{"name":"","range":"500 mm do 1000 mm","cmc":"(0,5 + 3 · L) µm"},{"name":"","range":"1000 mm do 1500 mm","cmc":"(0,7 + 3 · L) µm"},{"name":"","range":"1500 mm do 2000 mm","cmc":"(0,9 + 3 · L) µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC (0,35 + L) µm\n25 mm do 500 mm CMC (0,4 + 2,5 · L) µm\n500 mm do 1000 mm CMC (0,5 + 3 · L) µm\n1000 mm do 1500 mm CMC (0,7 + 3 · L) µm\n1500 mm do 2000 mm CMC (0,9 + 3 · L) µm\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"PWZ-1","norm_bases":["PWZ-1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":true,"location_of_activity":"P","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Mikroskopy pomiarowe uniwersalne\nMikroskopy pomiarowe warsztatowe Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC (0,35 + L) µm\n25 mm do 500 mm CMC (0,4 + 2,5 · L) µm\n500 mm do 1000 mm CMC (0,5 + 3 · L) µm\n1000 mm do 1500 mm CMC (0,7 + 3 · L) µm\n1500 mm do 2000 mm CMC (0,9 + 3 · L) µm\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) PWZ-1 Mikroskopy pomiarowe uniwersalne\nMikroskopy pomiarowe warsztatowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 25 mm CMC (0,35 + L) µm\n25 mm do 500 mm CMC (0,4 + 2,5 · L) µm\n500 mm do 1000 mm CMC (0,5 + 3 · L) µm\n1000 mm do 1500 mm CMC (0,7 + 3 · L) µm\n1500 mm do 2000 mm CMC (0,9 + 3 · L) µm\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) PWZ-1","search_en":"Universal measuring microscopes Workshop measuring microscopes Calibration — Length Internal procedure; Direct method; Outside of permanent location (P) Length Internal procedure Direct method Outside of permanent location (P) PWZ-1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 25 mm","cmc":"(0,35 + L) µm"},{"name":"","range":"25 mm do 500 mm","cmc":"(0,4 + 2,5 · L) µm"},{"name":"","range":"500 mm do 1000 mm","cmc":"(0,5 + 3 · L) µm"},{"name":"","range":"1000 mm do 1500 mm","cmc":"(0,7 + 3 · L) µm"},{"name":"","range":"1500 mm do 2000 mm","cmc":"(0,9 + 3 · L) µm"}],"regulatory_area_de":"Länge","search_de":"Universalmessmikroskope Werkstattmessmikroskope Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Länge Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) PWZ-1","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Universalmessmikroskope\nWerkstattmessmikroskope","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"(0,35 + L) µm"},{"name":"","range":"25 mm do 500 mm","cmc":"(0,4 + 2,5 · L) µm"},{"name":"","range":"500 mm do 1000 mm","cmc":"(0,5 + 3 · L) µm"},{"name":"","range":"1000 mm do 1500 mm","cmc":"(0,7 + 3 · L) µm"},{"name":"","range":"1500 mm do 2000 mm","cmc":"(0,9 + 3 · L) µm"}],"regulatory_area_zh":"长度","search_zh":"万能测量显微镜 工具测量显微镜 校准 — 长度 内部程序；直接法；固定地点以外 (P) 长度 内部程序 直接法 固定地点以外 (P) PWZ-1","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"万能测量显微镜\n工具测量显微镜","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 25 mm","cmc":"(0,35 + L) µm"},{"name":"","range":"25 mm do 500 mm","cmc":"(0,4 + 2,5 · L) µm"},{"name":"","range":"500 mm do 1000 mm","cmc":"(0,5 + 3 · L) µm"},{"name":"","range":"1000 mm do 1500 mm","cmc":"(0,7 + 3 · L) µm"},{"name":"","range":"1500 mm do 2000 mm","cmc":"(0,9 + 3 · L) µm"}],"regulatory_area_cs":"Délka","search_cs":"Univerzální měřicí mikroskopy Dílenské měřicí mikroskopy Kalibrace — Délka Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Délka Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) PWZ-1","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Univerzální měřicí mikroskopy\nDílenské měřicí mikroskopy"},{"_id":"76414346e7fe121fb5829ecd","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Projektory pomiarowe","test_object_en":"Measuring projectors","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 500 mm","cmc":"(0,3 + 3 · L) µm"}],"parameters_en":[{"name":"","range":"0 mm to 500 mm","cmc":"(0,3 + 3 · L) µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 500 mm CMC (0,3 + 3 · L) µm\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"PWZ-1","norm_bases":["PWZ-1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":true,"location_of_activity":"P","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Projektory pomiarowe Wzorcowanie — Długość\n0 mm do 500 mm CMC (0,3 + 3 · L) µm\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) PWZ-1 Projektory pomiarowe Wzorcowanie — Dlugosc\n0 mm do 500 mm CMC (0,3 + 3 · L) µm\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) PWZ-1","search_en":"Measuring projectors Calibration — Length Internal procedure; Direct method; Outside of permanent location (P) Length Internal procedure Direct method Outside of permanent location (P) PWZ-1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 500 mm","cmc":"(0,3 + 3 · L) µm"}],"regulatory_area_de":"Länge","search_de":"Messprojektoren Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Länge Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) PWZ-1","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Messprojektoren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 500 mm","cmc":"(0,3 + 3 · L) µm"}],"regulatory_area_zh":"长度","search_zh":"测量投影仪 校准 — 长度 内部程序；直接法；固定地点以外 (P) 长度 内部程序 直接法 固定地点以外 (P) PWZ-1","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"测量投影仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 500 mm","cmc":"(0,3 + 3 · L) µm"}],"regulatory_area_cs":"Délka","search_cs":"Měřicí projektory Kalibrace — Délka Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Délka Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) PWZ-1","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Měřicí projektory"},{"_id":"12f90922b2ce9dd9f47977a9","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Wysokościomierze cyfrowe o rozdzielczości:","test_object_en":"Digital height gauges with resolution:","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- 0,01 mm","range":"0 mm do 1000 mm","cmc":"6 µm"},{"name":"- 0,005 mm","range":"0 mm do 1000 mm","cmc":"3,5 µm"},{"name":"- 0,001 mm","range":"0 mm do 1000 mm","cmc":"(0,6 + 2 · L) µm"},{"name":"- 0,0005 mm","range":"0 mm do 1000 mm","cmc":"(0,3 + 2,5 · L) µm"},{"name":"- 0,0001 mm","range":"0 mm do 1000 mm","cmc":"(0,3 + 2,5 · L) µm"}],"parameters_en":[{"name":"- 0.01 mm","range":"0 mm to 1000 mm","cmc":"6 µm"},{"name":"- 0.005 mm","range":"0 mm to 1000 mm","cmc":"3,5 µm"},{"name":"- 0.001 mm","range":"0 mm to 1000 mm","cmc":"(0,6 + 2 · L) µm"},{"name":"- 0.0005 mm","range":"0 mm to 1000 mm","cmc":"(0,3 + 2,5 · L) µm"},{"name":"- 0.0001 mm","range":"0 mm to 1000 mm","cmc":"(0,3 + 2,5 · L) µm"}],"technique":"Poza stałą lokalizacją (P)","technique_en":"Outside of permanent location (P)","techniques":["Poza stałą lokalizacją (P)"],"techniques_en":["Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- 0,01 mm 0 mm do 1000 mm CMC 6 µm\n- 0,005 mm 0 mm do 1000 mm CMC 3,5 µm\n- 0,001 mm 0 mm do 1000 mm CMC (0,6 + 2 · L) µm\n- 0,0005 mm 0 mm do 1000 mm CMC (0,3 + 2,5 · L) µm\n- 0,0001 mm 0 mm do 1000 mm CMC (0,3 + 2,5 · L) µm\nPoza stałą lokalizacją (P)","reference":"PN-EN ISO 13225:2012","norm_bases":["PN-EN ISO 13225:2012"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":true,"location_of_activity":"P","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Wysokościomierze cyfrowe o rozdzielczości: Wzorcowanie — Długość\nZakres:\n- 0,01 mm 0 mm do 1000 mm CMC 6 µm\n- 0,005 mm 0 mm do 1000 mm CMC 3,5 µm\n- 0,001 mm 0 mm do 1000 mm CMC (0,6 + 2 · L) µm\n- 0,0005 mm 0 mm do 1000 mm CMC (0,3 + 2,5 · L) µm\n- 0,0001 mm 0 mm do 1000 mm CMC (0,3 + 2,5 · L) µm\nPoza stałą lokalizacją (P) PN-EN ISO 13225:2012 Wysokosciomierze cyfrowe o rozdzielczosci: Wzorcowanie — Dlugosc\nZakres:\n- 0,01 mm 0 mm do 1000 mm CMC 6 µm\n- 0,005 mm 0 mm do 1000 mm CMC 3,5 µm\n- 0,001 mm 0 mm do 1000 mm CMC (0,6 + 2 · L) µm\n- 0,0005 mm 0 mm do 1000 mm CMC (0,3 + 2,5 · L) µm\n- 0,0001 mm 0 mm do 1000 mm CMC (0,3 + 2,5 · L) µm\nPoza stala lokalizacja (P) PN-EN ISO 13225:2012","search_en":"Digital height gauges with resolution: Calibration — Length Outside of permanent location (P) Length Outside of permanent location (P) - 0.01 mm - 0.005 mm - 0.001 mm - 0.0005 mm - 0.0001 mm PN-EN ISO 13225:2012","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- 0,01 mm","range":"0 mm bis 1000 mm","cmc":"6 µm"},{"name":"- 0,005 mm","range":"0 mm bis 1000 mm","cmc":"3,5 µm"},{"name":"- 0,001 mm","range":"0 mm bis 1000 mm","cmc":"(0,6 + 2 · L) µm"},{"name":"- 0,0005 mm","range":"0 mm bis 1000 mm","cmc":"(0,3 + 2,5 · L) µm"},{"name":"- 0,0001 mm","range":"0 mm bis 1000 mm","cmc":"(0,3 + 2,5 · L) µm"}],"regulatory_area_de":"Länge","search_de":"Digitale Höhenmessgeräte mit Auflösung: Kalibrierung — Länge Außerhalb des festen Standorts (P) Länge Außerhalb des festen Standorts (P) - 0,01 mm - 0,005 mm - 0,001 mm - 0,0005 mm - 0,0001 mm PN-EN ISO 13225:2012","technique_de":"Außerhalb des festen Standorts (P)","techniques_de":["Außerhalb des festen Standorts (P)"],"test_object_de":"Digitale Höhenmessgeräte mit Auflösung:","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 0,01 mm","range":"0 mm 至 1000 mm","cmc":"6 µm"},{"name":"- 0,005 mm","range":"0 mm 至 1000 mm","cmc":"3,5 µm"},{"name":"- 0,001 mm","range":"0 mm 至 1000 mm","cmc":"(0,6 + 2 · L) µm"},{"name":"- 0,0005 mm","range":"0 mm 至 1000 mm","cmc":"(0,3 + 2,5 · L) µm"},{"name":"- 0,0001 mm","range":"0 mm 至 1000 mm","cmc":"(0,3 + 2,5 · L) µm"}],"regulatory_area_zh":"长度","search_zh":"分辨力为下列值的数显高度尺： 校准 — 长度 固定地点以外 (P) 长度 固定地点以外 (P) - 0,01 mm - 0,005 mm - 0,001 mm - 0,0005 mm - 0,0001 mm PN-EN ISO 13225:2012","technique_zh":"固定地点以外 (P)","techniques_zh":["固定地点以外 (P)"],"test_object_zh":"分辨力为下列值的数显高度尺：","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- 0,01 mm","range":"0 mm do 1000 mm","cmc":"6 µm"},{"name":"- 0,005 mm","range":"0 mm do 1000 mm","cmc":"3,5 µm"},{"name":"- 0,001 mm","range":"0 mm do 1000 mm","cmc":"(0,6 + 2 · L) µm"},{"name":"- 0,0005 mm","range":"0 mm do 1000 mm","cmc":"(0,3 + 2,5 · L) µm"},{"name":"- 0,0001 mm","range":"0 mm do 1000 mm","cmc":"(0,3 + 2,5 · L) µm"}],"regulatory_area_cs":"Délka","search_cs":"Digitální výškoměry s rozlišením: Kalibrace — Délka Mimo stálou lokalitu (P) Délka Mimo stálou lokalitu (P) - 0,01 mm - 0,005 mm - 0,001 mm - 0,0005 mm - 0,0001 mm PN-EN ISO 13225:2012","technique_cs":"Mimo stálou lokalitu (P)","techniques_cs":["Mimo stálou lokalitu (P)"],"test_object_cs":"Digitální výškoměry s rozlišením:"},{"_id":"b5b23edd3504c5863145b852","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Mikroskopy pomiarowe uniwersalne\nMikroskopy pomiarowe warsztatowe\nProjektory pomiarowe","test_object_en":"Universal measuring microscopes\nWorkshop measuring microscopes\nMeasuring projectors","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0° do 360°","cmc":"2’"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"2’"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0° do 360° CMC 2’\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"PWZ-1","norm_bases":["PWZ-1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Mikroskopy pomiarowe uniwersalne\nMikroskopy pomiarowe warsztatowe\nProjektory pomiarowe Wzorcowanie — Kąt\n0° do 360° CMC 2’\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) PWZ-1 Mikroskopy pomiarowe uniwersalne\nMikroskopy pomiarowe warsztatowe\nProjektory pomiarowe Wzorcowanie — Kat\n0° do 360° CMC 2’\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) PWZ-1","search_en":"Universal measuring microscopes Workshop measuring microscopes Measuring projectors Calibration — Angle Internal procedure; Direct method; Outside of permanent location (P) Angle Internal procedure Direct method Outside of permanent location (P) PWZ-1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0° bis 360°","cmc":"2’"}],"regulatory_area_de":"Winkel","search_de":"Universalmessmikroskope Werkstattmessmikroskope Messprojektoren Kalibrierung — Winkel Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Winkel Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) PWZ-1","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Universalmessmikroskope\nWerkstattmessmikroskope\nMessprojektoren","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"2’"}],"regulatory_area_zh":"角度","search_zh":"万能测量显微镜 工具测量显微镜 测量投影仪 校准 — 角度 内部程序；直接法；固定地点以外 (P) 角度 内部程序 直接法 固定地点以外 (P) PWZ-1","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"万能测量显微镜\n工具测量显微镜\n测量投影仪","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0° do 360°","cmc":"2’"}],"regulatory_area_cs":"Úhel","search_cs":"Univerzální měřicí mikroskopy Dílenské měřicí mikroskopy Měřicí projektory Kalibrace — Úhel Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Úhel Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) PWZ-1","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Univerzální měřicí mikroskopy\nDílenské měřicí mikroskopy\nMěřicí projektory"},{"_id":"727c9331c8f766ae6e94a1bf","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Głowice pomiarowe stykowe\nGłowice pomiarowe stykowe impulsowe\nGłowice pomiarowe stykowe skanujące","test_object_en":"Contact probes\nTouch-trigger contact probes\nScanning contact probes","methodology":"Wzorcowanie — Długość (pomiary współrzędnościowe)","methodology_en":"Calibration — Length (coordinate measurements)","parameters":[{"name":"","range":"0 mm do 25 mm","cmc":"0,14 µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"0,14 µm"}],"technique":"Poza stałą lokalizacją (P)","technique_en":"Outside of permanent location (P)","techniques":["Poza stałą lokalizacją (P)"],"techniques_en":["Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (pomiary współrzędnościowe)\n0 mm do 25 mm CMC 0,14 µm\nPoza stałą lokalizacją (P)","reference":"PN-EN ISO 10360-5:2020-10","norm_bases":["PN-EN ISO 10360-5:2020-10"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (pomiary współrzędnościowe)","regulatory_area_en":"Length (coordinate measurements)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Głowice pomiarowe stykowe\nGłowice pomiarowe stykowe impulsowe\nGłowice pomiarowe stykowe skanujące Wzorcowanie — Długość (pomiary współrzędnościowe)\n0 mm do 25 mm CMC 0,14 µm\nPoza stałą lokalizacją (P) PN-EN ISO 10360-5:2020-10 Glowice pomiarowe stykowe\nGlowice pomiarowe stykowe impulsowe\nGlowice pomiarowe stykowe skanujace Wzorcowanie — Dlugosc (pomiary wspolrzednosciowe)\n0 mm do 25 mm CMC 0,14 µm\nPoza stala lokalizacja (P) PN-EN ISO 10360-5:2020-10","search_en":"Contact probes Touch-trigger contact probes Scanning contact probes Calibration — Length (coordinate measurements) Outside of permanent location (P) Length (coordinate measurements) Outside of permanent location (P) PN-EN ISO 10360-5:2020-10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Koordinatenmessungen)","parameters_de":[{"name":"","range":"0 mm bis 25 mm","cmc":"0,14 µm"}],"regulatory_area_de":"Länge (Koordinatenmessungen)","search_de":"Taktile Messköpfe Schaltende taktile Tastköpfe Scannende taktile Tastköpfe Kalibrierung — Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) PN-EN ISO 10360-5:2020-10","technique_de":"Außerhalb des festen Standorts (P)","techniques_de":["Außerhalb des festen Standorts (P)"],"test_object_de":"Taktile Messköpfe\nSchaltende taktile Tastköpfe\nScannende taktile Tastköpfe","methodology_zh":"校准 — 长度（坐标测量）","parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"0,14 µm"}],"regulatory_area_zh":"长度（坐标测量）","search_zh":"接触式测头 触发式接触测头 扫描式接触测头 校准 — 长度（坐标测量） 固定地点以外 (P) 长度（坐标测量） 固定地点以外 (P) PN-EN ISO 10360-5:2020-10","technique_zh":"固定地点以外 (P)","techniques_zh":["固定地点以外 (P)"],"test_object_zh":"接触式测头\n触发式接触测头\n扫描式接触测头","methodology_cs":"Kalibrace — Délka (souřadnicová měření)","parameters_cs":[{"name":"","range":"0 mm do 25 mm","cmc":"0,14 µm"}],"regulatory_area_cs":"Délka (souřadnicová měření)","search_cs":"Dotykové měřicí hlavy Spínací dotykové sondy Skenovací dotykové sondy Kalibrace — Délka (souřadnicová měření) Mimo stálou lokalitu (P) Délka (souřadnicová měření) Mimo stálou lokalitu (P) PN-EN ISO 10360-5:2020-10","technique_cs":"Mimo stálou lokalitu (P)","techniques_cs":["Mimo stálou lokalitu (P)"],"test_object_cs":"Dotykové měřicí hlavy\nSpínací dotykové sondy\nSkenovací dotykové sondy"},{"_id":"1126a42b51571462dbbf1210","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Współrzędnościowe maszyny pomiarowe z głowicą pomiarową stykową","test_object_en":"Coordinate measuring machines with a contact probe","methodology":"Wzorcowanie — Długość (pomiary współrzędnościowe)","methodology_en":"Calibration — Length (coordinate measurements)","parameters":[{"name":"","range":"0 mm do 1515 mm","cmc":"(0,2 + 0,5 · L) µm"},{"name":"","range":"1515 mm do 2880 mm","cmc":"(0,3 + 0,6 · L) µm"},{"name":"","range":"2880 mm do 4090 mm","cmc":"(0,4 + 0,7 · L) µm"}],"parameters_en":[{"name":"","range":"0 mm to 1515 mm","cmc":"(0,2 + 0,5 · L) µm"},{"name":"","range":"1515 mm to 2880 mm","cmc":"(0,3 + 0,6 · L) µm"},{"name":"","range":"2880 mm to 4090 mm","cmc":"(0,4 + 0,7 · L) µm"}],"technique":"Poza stałą lokalizacją (P)","technique_en":"Outside of permanent location (P)","techniques":["Poza stałą lokalizacją (P)"],"techniques_en":["Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (pomiary współrzędnościowe)\nZakres:\n0 mm do 1515 mm CMC (0,2 + 0,5 · L) µm\n1515 mm do 2880 mm CMC (0,3 + 0,6 · L) µm\n2880 mm do 4090 mm CMC (0,4 + 0,7 · L) µm\nPoza stałą lokalizacją (P)","reference":"PN-EN ISO 10360-2:2010","norm_bases":["PN-EN ISO 10360-2:2010"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (pomiary współrzędnościowe)","regulatory_area_en":"Length (coordinate measurements)","outside_premises":true,"location_of_activity":"P","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Współrzędnościowe maszyny pomiarowe z głowicą pomiarową stykową Wzorcowanie — Długość (pomiary współrzędnościowe)\nZakres:\n0 mm do 1515 mm CMC (0,2 + 0,5 · L) µm\n1515 mm do 2880 mm CMC (0,3 + 0,6 · L) µm\n2880 mm do 4090 mm CMC (0,4 + 0,7 · L) µm\nPoza stałą lokalizacją (P) PN-EN ISO 10360-2:2010 Wspolrzednosciowe maszyny pomiarowe z glowica pomiarowa stykowa Wzorcowanie — Dlugosc (pomiary wspolrzednosciowe)\nZakres:\n0 mm do 1515 mm CMC (0,2 + 0,5 · L) µm\n1515 mm do 2880 mm CMC (0,3 + 0,6 · L) µm\n2880 mm do 4090 mm CMC (0,4 + 0,7 · L) µm\nPoza stala lokalizacja (P) PN-EN ISO 10360-2:2010","search_en":"Coordinate measuring machines with a contact probe Calibration — Length (coordinate measurements) Outside of permanent location (P) Length (coordinate measurements) Outside of permanent location (P) PN-EN ISO 10360-2:2010","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Koordinatenmessungen)","parameters_de":[{"name":"","range":"0 mm to 1515 mm","cmc":"(0,2 + 0,5 · L) µm"},{"name":"","range":"1515 mm to 2880 mm","cmc":"(0,3 + 0,6 · L) µm"},{"name":"","range":"2880 mm to 4090 mm","cmc":"(0,4 + 0,7 · L) µm"}],"regulatory_area_de":"Länge (Koordinatenmessungen)","search_de":"Koordinatenmessgeräte mit taktilem Messkopf Kalibrierung — Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) PN-EN ISO 10360-2:2010","technique_de":"Außerhalb des festen Standorts (P)","techniques_de":["Außerhalb des festen Standorts (P)"],"test_object_de":"Koordinatenmessgeräte mit taktilem Messkopf","methodology_zh":"校准 — 长度（坐标测量）","parameters_zh":[{"name":"","range":"0 mm to 1515 mm","cmc":"(0,2 + 0,5 · L) µm"},{"name":"","range":"1515 mm to 2880 mm","cmc":"(0,3 + 0,6 · L) µm"},{"name":"","range":"2880 mm to 4090 mm","cmc":"(0,4 + 0,7 · L) µm"}],"regulatory_area_zh":"长度（坐标测量）","search_zh":"带接触式测头的坐标测量机 校准 — 长度（坐标测量） 固定地点以外 (P) 长度（坐标测量） 固定地点以外 (P) PN-EN ISO 10360-2:2010","technique_zh":"固定地点以外 (P)","techniques_zh":["固定地点以外 (P)"],"test_object_zh":"带接触式测头的坐标测量机","methodology_cs":"Kalibrace — Délka (souřadnicová měření)","parameters_cs":[{"name":"","range":"0 mm to 1515 mm","cmc":"(0,2 + 0,5 · L) µm"},{"name":"","range":"1515 mm to 2880 mm","cmc":"(0,3 + 0,6 · L) µm"},{"name":"","range":"2880 mm to 4090 mm","cmc":"(0,4 + 0,7 · L) µm"}],"regulatory_area_cs":"Délka (souřadnicová měření)","search_cs":"Souřadnicové měřicí stroje s dotykovou měřicí hlavou Kalibrace — Délka (souřadnicová měření) Mimo stálou lokalitu (P) Délka (souřadnicová měření) Mimo stálou lokalitu (P) PN-EN ISO 10360-2:2010","technique_cs":"Mimo stálou lokalitu (P)","techniques_cs":["Mimo stálou lokalitu (P)"],"test_object_cs":"Souřadnicové měřicí stroje s dotykovou měřicí hlavou"},{"_id":"798302d262d3b1aa2c050ea1","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Optyczne współrzędnościowe maszyny pomiarowe z głowicą pomiarową rejestrującą obraz","test_object_en":"Optical coordinate measuring machines with an imaging probe","methodology":"Wzorcowanie — Długość (pomiary współrzędnościowe)","methodology_en":"Calibration — Length (coordinate measurements)","parameters":[{"name":"","range":"0 mm do 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"parameters_en":[{"name":"","range":"0 mm to 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"technique":"Poza stałą lokalizacją (P)","technique_en":"Outside of permanent location (P)","techniques":["Poza stałą lokalizacją (P)"],"techniques_en":["Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (pomiary współrzędnościowe)\n0 mm do 758 mm CMC (0,3 + 0,6 · L) µm\nPoza stałą lokalizacją (P)","reference":"PN-EN ISO 10360-7:2011","norm_bases":["PN-EN ISO 10360-7:2011"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (pomiary współrzędnościowe)","regulatory_area_en":"Length (coordinate measurements)","outside_premises":true,"location_of_activity":"P","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Optyczne współrzędnościowe maszyny pomiarowe z głowicą pomiarową rejestrującą obraz Wzorcowanie — Długość (pomiary współrzędnościowe)\n0 mm do 758 mm CMC (0,3 + 0,6 · L) µm\nPoza stałą lokalizacją (P) PN-EN ISO 10360-7:2011 Optyczne wspolrzednosciowe maszyny pomiarowe z glowica pomiarowa rejestrujaca obraz Wzorcowanie — Dlugosc (pomiary wspolrzednosciowe)\n0 mm do 758 mm CMC (0,3 + 0,6 · L) µm\nPoza stala lokalizacja (P) PN-EN ISO 10360-7:2011","search_en":"Optical coordinate measuring machines with an imaging probe Calibration — Length (coordinate measurements) Outside of permanent location (P) Length (coordinate measurements) Outside of permanent location (P) PN-EN ISO 10360-7:2011","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Koordinatenmessungen)","parameters_de":[{"name":"","range":"0 mm to 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"regulatory_area_de":"Länge (Koordinatenmessungen)","search_de":"Optische Koordinatenmessgeräte mit bildverarbeitendem Messkopf Kalibrierung — Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) PN-EN ISO 10360-7:2011","technique_de":"Außerhalb des festen Standorts (P)","techniques_de":["Außerhalb des festen Standorts (P)"],"test_object_de":"Optische Koordinatenmessgeräte mit bildverarbeitendem Messkopf","methodology_zh":"校准 — 长度（坐标测量）","parameters_zh":[{"name":"","range":"0 mm to 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"regulatory_area_zh":"长度（坐标测量）","search_zh":"带图像采集测头的光学坐标测量机 校准 — 长度（坐标测量） 固定地点以外 (P) 长度（坐标测量） 固定地点以外 (P) PN-EN ISO 10360-7:2011","technique_zh":"固定地点以外 (P)","techniques_zh":["固定地点以外 (P)"],"test_object_zh":"带图像采集测头的光学坐标测量机","methodology_cs":"Kalibrace — Délka (souřadnicová měření)","parameters_cs":[{"name":"","range":"0 mm to 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"regulatory_area_cs":"Délka (souřadnicová měření)","search_cs":"Optické souřadnicové měřicí stroje s měřicí hlavou snímající obraz Kalibrace — Délka (souřadnicová měření) Mimo stálou lokalitu (P) Délka (souřadnicová měření) Mimo stálou lokalitu (P) PN-EN ISO 10360-7:2011","technique_cs":"Mimo stálou lokalitu (P)","techniques_cs":["Mimo stálou lokalitu (P)"],"test_object_cs":"Optické souřadnicové měřicí stroje s měřicí hlavou snímající obraz"},{"_id":"0a0e2d1b87abc48c0cadcccf","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Optyczne współrzędnościowe mikroskopy pomiarowe","test_object_en":"Optical coordinate measuring microscopes","methodology":"Wzorcowanie — Długość (pomiary współrzędnościowe)","methodology_en":"Calibration — Length (coordinate measurements)","parameters":[{"name":"","range":"0 mm do 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"parameters_en":[{"name":"","range":"0 mm to 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"technique":"Poza stałą lokalizacją (P)","technique_en":"Outside of permanent location (P)","techniques":["Poza stałą lokalizacją (P)"],"techniques_en":["Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (pomiary współrzędnościowe)\n0 mm do 758 mm CMC (0,3 + 0,6 · L) µm\nPoza stałą lokalizacją (P)","reference":"PN-EN ISO 10360-7:2011","norm_bases":["PN-EN ISO 10360-7:2011"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (pomiary współrzędnościowe)","regulatory_area_en":"Length (coordinate measurements)","outside_premises":true,"location_of_activity":"P","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Optyczne współrzędnościowe mikroskopy pomiarowe Wzorcowanie — Długość (pomiary współrzędnościowe)\n0 mm do 758 mm CMC (0,3 + 0,6 · L) µm\nPoza stałą lokalizacją (P) PN-EN ISO 10360-7:2011 Optyczne wspolrzednosciowe mikroskopy pomiarowe Wzorcowanie — Dlugosc (pomiary wspolrzednosciowe)\n0 mm do 758 mm CMC (0,3 + 0,6 · L) µm\nPoza stala lokalizacja (P) PN-EN ISO 10360-7:2011","search_en":"Optical coordinate measuring microscopes Calibration — Length (coordinate measurements) Outside of permanent location (P) Length (coordinate measurements) Outside of permanent location (P) PN-EN ISO 10360-7:2011","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Koordinatenmessungen)","parameters_de":[{"name":"","range":"0 mm to 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"regulatory_area_de":"Länge (Koordinatenmessungen)","search_de":"Optische Koordinatenmessmikroskope Kalibrierung — Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) PN-EN ISO 10360-7:2011","technique_de":"Außerhalb des festen Standorts (P)","techniques_de":["Außerhalb des festen Standorts (P)"],"test_object_de":"Optische Koordinatenmessmikroskope","methodology_zh":"校准 — 长度（坐标测量）","parameters_zh":[{"name":"","range":"0 mm to 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"regulatory_area_zh":"长度（坐标测量）","search_zh":"光学坐标测量显微镜 校准 — 长度（坐标测量） 固定地点以外 (P) 长度（坐标测量） 固定地点以外 (P) PN-EN ISO 10360-7:2011","technique_zh":"固定地点以外 (P)","techniques_zh":["固定地点以外 (P)"],"test_object_zh":"光学坐标测量显微镜","methodology_cs":"Kalibrace — Délka (souřadnicová měření)","parameters_cs":[{"name":"","range":"0 mm to 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"regulatory_area_cs":"Délka (souřadnicová měření)","search_cs":"Optické souřadnicové měřicí mikroskopy Kalibrace — Délka (souřadnicová měření) Mimo stálou lokalitu (P) Délka (souřadnicová měření) Mimo stálou lokalitu (P) PN-EN ISO 10360-7:2011","technique_cs":"Mimo stálou lokalitu (P)","techniques_cs":["Mimo stálou lokalitu (P)"],"test_object_cs":"Optické souřadnicové měřicí mikroskopy"},{"_id":"7a4a533b99944cec1b30a512","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Optyczne współrzędnościowe projektory pomiarowe","test_object_en":"Optical coordinate measuring projectors","methodology":"Wzorcowanie — Długość (pomiary współrzędnościowe)","methodology_en":"Calibration — Length (coordinate measurements)","parameters":[{"name":"","range":"0 mm do 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"parameters_en":[{"name":"","range":"0 mm to 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"technique":"Poza stałą lokalizacją (P)","technique_en":"Outside of permanent location (P)","techniques":["Poza stałą lokalizacją (P)"],"techniques_en":["Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (pomiary współrzędnościowe)\n0 mm do 758 mm CMC (0,3 + 0,6 · L) µm\nPoza stałą lokalizacją (P)","reference":"PN-EN ISO 10360-7:2011","norm_bases":["PN-EN ISO 10360-7:2011"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (pomiary współrzędnościowe)","regulatory_area_en":"Length (coordinate measurements)","outside_premises":true,"location_of_activity":"P","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Optyczne współrzędnościowe projektory pomiarowe Wzorcowanie — Długość (pomiary współrzędnościowe)\n0 mm do 758 mm CMC (0,3 + 0,6 · L) µm\nPoza stałą lokalizacją (P) PN-EN ISO 10360-7:2011 Optyczne wspolrzednosciowe projektory pomiarowe Wzorcowanie — Dlugosc (pomiary wspolrzednosciowe)\n0 mm do 758 mm CMC (0,3 + 0,6 · L) µm\nPoza stala lokalizacja (P) PN-EN ISO 10360-7:2011","search_en":"Optical coordinate measuring projectors Calibration — Length (coordinate measurements) Outside of permanent location (P) Length (coordinate measurements) Outside of permanent location (P) PN-EN ISO 10360-7:2011","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Koordinatenmessungen)","parameters_de":[{"name":"","range":"0 mm to 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"regulatory_area_de":"Länge (Koordinatenmessungen)","search_de":"Optische Koordinatenmessprojektoren Kalibrierung — Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) PN-EN ISO 10360-7:2011","technique_de":"Außerhalb des festen Standorts (P)","techniques_de":["Außerhalb des festen Standorts (P)"],"test_object_de":"Optische Koordinatenmessprojektoren","methodology_zh":"校准 — 长度（坐标测量）","parameters_zh":[{"name":"","range":"0 mm to 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"regulatory_area_zh":"长度（坐标测量）","search_zh":"光学坐标测量投影仪 校准 — 长度（坐标测量） 固定地点以外 (P) 长度（坐标测量） 固定地点以外 (P) PN-EN ISO 10360-7:2011","technique_zh":"固定地点以外 (P)","techniques_zh":["固定地点以外 (P)"],"test_object_zh":"光学坐标测量投影仪","methodology_cs":"Kalibrace — Délka (souřadnicová měření)","parameters_cs":[{"name":"","range":"0 mm to 758 mm","cmc":"(0,3 + 0,6 · L) µm"}],"regulatory_area_cs":"Délka (souřadnicová měření)","search_cs":"Optické souřadnicové měřicí projektory Kalibrace — Délka (souřadnicová měření) Mimo stálou lokalitu (P) Délka (souřadnicová měření) Mimo stálou lokalitu (P) PN-EN ISO 10360-7:2011","technique_cs":"Mimo stálou lokalitu (P)","techniques_cs":["Mimo stálou lokalitu (P)"],"test_object_cs":"Optické souřadnicové měřicí projektory"},{"_id":"87629dbc5df9bc1ce402a069","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Współrzędnościowe ramiona pomiarowe z głowicą pomiarową stykową","test_object_en":"Articulated arm coordinate measuring machines with a contact probe","methodology":"Wzorcowanie — Długość (pomiary współrzędnościowe)","methodology_en":"Calibration — Length (coordinate measurements)","parameters":[{"name":"","range":"0 mm do 4500 mm","cmc":"(4 + 1 · L) µm"}],"parameters_en":[{"name":"","range":"0 mm to 4500 mm","cmc":"(4 + 1 · L) µm"}],"technique":"Poza stałą lokalizacją (P)","technique_en":"Outside of permanent location (P)","techniques":["Poza stałą lokalizacją (P)"],"techniques_en":["Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (pomiary współrzędnościowe)\n0 mm do 4500 mm CMC (4 + 1 · L) µm\nPoza stałą lokalizacją (P)","reference":"ASME B89.4.22:2004, PN-EN ISO 10360-12:2017","norm_bases":["ASME B89.4.22:2004","PN-EN ISO 10360-12:2017"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (pomiary współrzędnościowe)","regulatory_area_en":"Length (coordinate measurements)","outside_premises":true,"location_of_activity":"P","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Współrzędnościowe ramiona pomiarowe z głowicą pomiarową stykową Wzorcowanie — Długość (pomiary współrzędnościowe)\n0 mm do 4500 mm CMC (4 + 1 · L) µm\nPoza stałą lokalizacją (P) ASME B89.4.22:2004, PN-EN ISO 10360-12:2017 Wspolrzednosciowe ramiona pomiarowe z glowica pomiarowa stykowa Wzorcowanie — Dlugosc (pomiary wspolrzednosciowe)\n0 mm do 4500 mm CMC (4 + 1 · L) µm\nPoza stala lokalizacja (P) ASME B89.4.22:2004, PN-EN ISO 10360-12:2017","search_en":"Articulated arm coordinate measuring machines with a contact probe Calibration — Length (coordinate measurements) Outside of permanent location (P) Length (coordinate measurements) Outside of permanent location (P) ASME B89.4.22:2004, PN-EN ISO 10360-12:2017","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Koordinatenmessungen)","parameters_de":[{"name":"","range":"0 mm to 4500 mm","cmc":"(4 + 1 · L) µm"}],"regulatory_area_de":"Länge (Koordinatenmessungen)","search_de":"Gelenkarm-Koordinatenmessgeräte mit taktilem Tastsystem Kalibrierung — Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) ASME B89.4.22:2004, PN-EN ISO 10360-12:2017","technique_de":"Außerhalb des festen Standorts (P)","techniques_de":["Außerhalb des festen Standorts (P)"],"test_object_de":"Gelenkarm-Koordinatenmessgeräte mit taktilem Tastsystem","methodology_zh":"校准 — 长度（坐标测量）","parameters_zh":[{"name":"","range":"0 mm to 4500 mm","cmc":"(4 + 1 · L) µm"}],"regulatory_area_zh":"长度（坐标测量）","search_zh":"带接触式测头的关节臂坐标测量机 校准 — 长度（坐标测量） 固定地点以外 (P) 长度（坐标测量） 固定地点以外 (P) ASME B89.4.22:2004, PN-EN ISO 10360-12:2017","technique_zh":"固定地点以外 (P)","techniques_zh":["固定地点以外 (P)"],"test_object_zh":"带接触式测头的关节臂坐标测量机","methodology_cs":"Kalibrace — Délka (souřadnicová měření)","parameters_cs":[{"name":"","range":"0 mm to 4500 mm","cmc":"(4 + 1 · L) µm"}],"regulatory_area_cs":"Délka (souřadnicová měření)","search_cs":"Souřadnicová měřicí ramena s dotykovou sondou Kalibrace — Délka (souřadnicová měření) Mimo stálou lokalitu (P) Délka (souřadnicová měření) Mimo stálou lokalitu (P) ASME B89.4.22:2004, PN-EN ISO 10360-12:2017","technique_cs":"Mimo stálou lokalitu (P)","techniques_cs":["Mimo stálou lokalitu (P)"],"test_object_cs":"Souřadnicová měřicí ramena s dotykovou sondou"},{"_id":"2d6e70a40db1c5d52f2f1f9e","lab_id":"6af7989b0ecd48de0c7068ae","country":"PL","accr_number":"AP 236","accr_body":"PCA","test_object":"Współrzędnościowe systemy pomiarowe z głowicą pomiarową optyczną mierzącą odległość:\n- współrzędnościowe maszyny pomiarowe\n- współrzędnościowe ramiona pomiarowe\n- współrzędnościowe skanery optyczne","test_object_en":"Coordinate measuring systems with an optical distance sensor:\n- coordinate measuring machines\n- articulated arm coordinate measuring machines\n- optical coordinate scanners","methodology":"Wzorcowanie — Długość (pomiary współrzędnościowe)","methodology_en":"Calibration — Length (coordinate measurements)","parameters":[{"name":"","range":"0 mm do 1500 mm","cmc":"(2 + 1 · L) µm"}],"parameters_en":[{"name":"","range":"0 mm to 1500 mm","cmc":"(2 + 1 · L) µm"}],"technique":"Poza stałą lokalizacją (P)","technique_en":"Outside of permanent location (P)","techniques":["Poza stałą lokalizacją (P)"],"techniques_en":["Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (pomiary współrzędnościowe)\n0 mm do 1500 mm CMC (2 + 1 · L) µm\nPoza stałą lokalizacją (P)","reference":"VDI/VDE 2634 Blat 2 2012, VDI/VDE 2634 Blat 3 2008, PN-EN ISO 10360-8:2014, PN-EN ISO 10360-13:2022","norm_bases":["VDI/VDE 2634 Blat 2 2012","VDI/VDE 2634 Blat 3 2008","PN-EN ISO 10360-8:2014","PN-EN ISO 10360-13:2022"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (pomiary współrzędnościowe)","regulatory_area_en":"Length (coordinate measurements)","outside_premises":true,"location_of_activity":"P","note":"L – wielkość mierzona (m)","note_en":"L – measured quantity (m)","search_text":"Współrzędnościowe systemy pomiarowe z głowicą pomiarową optyczną mierzącą odległość:\n- współrzędnościowe maszyny pomiarowe\n- współrzędnościowe ramiona pomiarowe\n- współrzędnościowe skanery optyczne Wzorcowanie — Długość (pomiary współrzędnościowe)\n0 mm do 1500 mm CMC (2 + 1 · L) µm\nPoza stałą lokalizacją (P) VDI/VDE 2634 Blat 2 2012, VDI/VDE 2634 Blat 3 2008, PN-EN ISO 10360-8:2014, PN-EN ISO 10360-13:2022 Wspolrzednosciowe systemy pomiarowe z glowica pomiarowa optyczna mierzaca odleglosc:\n- wspolrzednosciowe maszyny pomiarowe\n- wspolrzednosciowe ramiona pomiarowe\n- wspolrzednosciowe skanery optyczne Wzorcowanie — Dlugosc (pomiary wspolrzednosciowe)\n0 mm do 1500 mm CMC (2 + 1 · L) µm\nPoza stala lokalizacja (P) VDI/VDE 2634 Blat 2 2012, VDI/VDE 2634 Blat 3 2008, PN-EN ISO 10360-8:2014, PN-EN ISO 10360-13:2022","search_en":"Coordinate measuring systems with an optical distance sensor: - coordinate measuring machines - articulated arm coordinate measuring machines - optical coordinate scanners Calibration — Length (coordinate measurements) Outside of permanent location (P) Length (coordinate measurements) Outside of permanent location (P) VDI/VDE 2634 Blat 2 2012, VDI/VDE 2634 Blat 3 2008, PN-EN ISO 10360-8:2014, PN-EN ISO 10360-13:2022","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Koordinatenmessungen)","parameters_de":[{"name":"","range":"0 mm to 1500 mm","cmc":"(2 + 1 · L) µm"}],"regulatory_area_de":"Länge (Koordinatenmessungen)","search_de":"Koordinatenmesssysteme mit optischem Abstandssensor: - Koordinatenmessgeräte - Gelenkarm-Koordinatenmessgeräte - optische Koordinatenscanner Kalibrierung — Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) Länge (Koordinatenmessungen) Außerhalb des festen Standorts (P) VDI/VDE 2634 Blat 2 2012, VDI/VDE 2634 Blat 3 2008, PN-EN ISO 10360-8:2014, PN-EN ISO 10360-13:2022","technique_de":"Außerhalb des festen Standorts (P)","techniques_de":["Außerhalb des festen Standorts (P)"],"test_object_de":"Koordinatenmesssysteme mit optischem Abstandssensor:\n- Koordinatenmessgeräte\n- Gelenkarm-Koordinatenmessgeräte\n- optische Koordinatenscanner","methodology_zh":"校准 — 长度（坐标测量）","parameters_zh":[{"name":"","range":"0 mm to 1500 mm","cmc":"(2 + 1 · L) µm"}],"regulatory_area_zh":"长度（坐标测量）","search_zh":"带光学测距测头的坐标测量系统： - 坐标测量机 - 关节臂坐标测量机 - 光学坐标扫描仪 校准 — 长度（坐标测量） 固定地点以外 (P) 长度（坐标测量） 固定地点以外 (P) VDI/VDE 2634 Blat 2 2012, VDI/VDE 2634 Blat 3 2008, PN-EN ISO 10360-8:2014, PN-EN ISO 10360-13:2022","technique_zh":"固定地点以外 (P)","techniques_zh":["固定地点以外 (P)"],"test_object_zh":"带光学测距测头的坐标测量系统：\n- 坐标测量机\n- 关节臂坐标测量机\n- 光学坐标扫描仪","methodology_cs":"Kalibrace — Délka (souřadnicová měření)","parameters_cs":[{"name":"","range":"0 mm to 1500 mm","cmc":"(2 + 1 · L) µm"}],"regulatory_area_cs":"Délka (souřadnicová měření)","search_cs":"Souřadnicové měřicí systémy s optickou měřicí hlavou měřící vzdálenost: - souřadnicové měřicí stroje - souřadnicová měřicí ramena - souřadnicové optické skenery Kalibrace — Délka (souřadnicová měření) Mimo stálou lokalitu (P) Délka (souřadnicová měření) Mimo stálou lokalitu (P) VDI/VDE 2634 Blat 2 2012, VDI/VDE 2634 Blat 3 2008, PN-EN ISO 10360-8:2014, PN-EN ISO 10360-13:2022","technique_cs":"Mimo stálou lokalitu (P)","techniques_cs":["Mimo stálou lokalitu (P)"],"test_object_cs":"Souřadnicové měřicí systémy s optickou měřicí hlavou měřící vzdálenost:\n- souřadnicové měřicí stroje\n- souřadnicová měřicí ramena\n- souřadnicové optické skenery"}],"has_pdf":true}