{"lab":{"_id":"6af574720ecd48de0c70623d","accr_number":"AP 232","country":"PL","imported_at":"2026-11-11T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"ul. Jana Pawła II 14, 61-139 Poznań","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"21.01.2026","city":"Poznań","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 %. Niepewność pomiaru dla CMC wyrażona jest w jednostkach wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The uncertainty covered by the CMC is expressed in measurand units.","cycle_from":"15.09.2025","cycle_to":"14.09.2029","email_source":"PCA","en_official":true,"fields_of_testing":[{"codes":"19.01","pl":"temperatura (termometria elektryczna)","en":"temperature (electrical thermometry)","de":"Temperatur (elektrische Thermometrie)","zh":"温度（电测温）","cs":"teplota (elektrická termometrie)"}],"has_en":true,"has_zh":true,"issue":{"no":"3","date":"05.02.2026"},"issue_date":"05.02.2026","issue_number":"3","lab_division":"Laboratorium Obróbki Cieplnej i Metrologii","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[16.9531712,52.4036579]},"map_coord":[52.4036579,16.9531712],"map_geo":"nominatim-street","methods_count":1,"name":"Sieć Badawcza Łukasiewicz  - Poznański Instytut Technologiczny","parse_date":"2026-11-11T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-11T12:00:00.000Z","pdf_files":["AP_232.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: temperatura (termometria elektryczna). W stałej lokalizacji (S).","search_text":"sieć badawcza łukasiewicz  - poznański instytut technologiczny laboratorium obróbki cieplnej i metrologii ul. jana pawła ii 14, 61-139 poznań laboratorium wzorcujące. wielkości mierzone: temperatura (termometria elektryczna). w stałej lokalizacji (s). ap 232 ap232 laboratorium wzorcujące wzorcowanie kalibracja temperature (electrical thermometry) siec badawcza lukasiewicz  - poznanski instytut technologiczny laboratorium obrobki cieplnej i metrologii ul. jana pawla ii 14, 61-139 poznan laboratorium wzorcujace. wielkosci mierzone: temperatura (termometria elektryczna). w stalej lokalizacji (s). ap 232 ap232 laboratorium wzorcujace wzorcowanie kalibracja temperature (electrical thermometry)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20232,podmiot.html","source_pdf_sha256":"6d033cf2be744e2537e81ec61c7157a9ec78c39d654e85af1e5a5ce8bae36d84","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/11/74fab9f116045cb8a8dbbb9d84d3ffa0/AP%20232.pdf","status":"active","updated_at":"2026-11-11T12:00:00.000Z","valid_from":"15-09-2025","valid_until":"14-09-2029","website":"pit.lukasiewicz.gov.pl","lab_division_en":"Heat Treatment and Metrology Laboratory","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 %. Die Messunsicherheit der CMC wird in Einheiten der Messgröße angegeben.","has_de":true,"lab_division_de":"Labor für Wärmebehandlung und Metrologie","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度。CMC测量不确定度以被测量的单位表示。","lab_division_zh":"热处理与计量实验室","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 %. Nejistota měření CMC je vyjádřena v jednotkách měřené veličiny.","has_cs":true,"lab_division_cs":"Laboratoř tepelného zpracování a metrologie","pelny_cs":true},"methods":[{"_id":"27d7da340a42e727c263861a","lab_id":"6af574720ecd48de0c70623d","country":"PL","accr_number":"AP 232","accr_body":"PCA","test_object":"Temometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury)","test_object_en":"Electric thermometers (including electronic thermometers)\nElectrical thermometer with data logger","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-40 °C do 90 °C","cmc":"0,25 °C"},{"name":"","range":"90 °C do 150 °C","cmc":"0,4 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 90 °C","cmc":"0,25 °C"},{"name":"","range":"90 °C to 150 °C","cmc":"0,4 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w komorze termostatycznej; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method\nCalibration in a thermostatic chamber; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia\nWzorcowanie w komorze termostatycznej","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method\nCalibration in a thermostatic chamber","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-40 °C do 90 °C CMC 0,25 °C\n90 °C do 150 °C CMC 0,4 °C\nProcedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w komorze termostatycznej; W stałej lokalizacji (S)","reference":"PW-BLC-03","norm_bases":["PW-BLC-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Temometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-40 °C do 90 °C CMC 0,25 °C\n90 °C do 150 °C CMC 0,4 °C\nProcedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w komorze termostatycznej; W stałej lokalizacji (S) PW-BLC-03 Temometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-40 °C do 90 °C CMC 0,25 °C\n90 °C do 150 °C CMC 0,4 °C\nProcedura wewnetrzna; Metoda bezposrednia\nWzorcowanie w komorze termostatycznej; W stalej lokalizacji (S) PW-BLC-03","search_en":"Electric thermometers (including electronic thermometers) Electrical thermometer with data logger Calibration — Temperature (electrical thermometry) Internal procedure; Direct method Calibration in a thermostatic chamber; At permanent location (S) Temperature (electrical thermometry) Internal procedure Direct method Calibration in a thermostatic chamber At permanent location (S) PW-BLC-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-40 °C to 90 °C","cmc":"0,25 °C"},{"name":"","range":"90 °C to 150 °C","cmc":"0,4 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren Kalibrierung in einer Thermostatkammer; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Kalibrierung in einer Thermostatkammer Am festen Standort (S) PW-BLC-03","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren\nKalibrierung in einer Thermostatkammer; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren\nKalibrierung in einer Thermostatkammer","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-40 °C to 90 °C","cmc":"0,25 °C"},{"name":"","range":"90 °C to 150 °C","cmc":"0,4 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序；直接法 在恒温箱中校准；在固定地点 (S) 温度（电测温） 内部程序 直接法 在恒温箱中校准 在固定地点 (S) PW-BLC-03","technique_zh":"内部程序；直接法\n在恒温箱中校准；在固定地点 (S)","techniques_zh":["内部程序","直接法\n在恒温箱中校准","在固定地点 (S)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-40 °C to 90 °C","cmc":"0,25 °C"},{"name":"","range":"90 °C to 150 °C","cmc":"0,4 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda Kalibrace v termostatické komoře; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Kalibrace v termostatické komoře Ve stálé lokalitě (S) PW-BLC-03","technique_cs":"Vnitřní postup; Přímá metoda\nKalibrace v termostatické komoře; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda\nKalibrace v termostatické komoře","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"}],"has_pdf":true}