{"lab":{"_id":"6af7989a0ecd48de0c7068ac","country":"PL","accr_number":"AP 226","imported_at":"2026-11-13T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"ul. Wincentego Pola 2, 35-021 Rzeszów","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"13.03.2025","city":"Rzeszów","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units.","cycle_from":"13.03.2025","cycle_to":"12.03.2029","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"7.01","pl":"napięcie DC","en":"DC voltage","de":"Gleichspannung","zh":"直流电压","cs":"stejnosměrné napětí (DC)"},{"codes":"7.02","pl":"prąd DC","en":"DC current","de":"DC-Strom","zh":"直流电流","cs":"proud DC"},{"codes":"7.03","pl":"napięcie AC","en":"AC voltage","de":"AC-Spannung","zh":"交流电压","cs":"napětí AC"},{"codes":"7.04","pl":"prąd AC","en":"AC current","de":"AC-Strom","zh":"交流电流","cs":"proud AC"},{"codes":"7.05","pl":"rezystancja DC","en":"DC resistance","de":"DC-Widerstand","zh":"直流电阻","cs":"odpor DC"}],"has_en":true,"has_zh":true,"issue":{"no":"2","date":"27.01.2026"},"issue_date":"27.01.2026","issue_number":"2","lab_division":"Laboratorium Badań i Kalibracji LABBiKAL","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[21.9853499,50.0268335]},"map_coord":[50.0268335,21.9853499],"map_geo":"nominatim-street","methods_count":5,"name":"Politechnika Rzeszowska im. Ignacego Łukasiewicza","parse_date":"2026-11-13T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-13T12:00:00.000Z","pdf_files":["AP_226.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: napięcie DC, prąd DC, napięcie AC, prąd AC, rezystancja DC. W stałej lokalizacji (S).","search_text":"politechnika rzeszowska im. ignacego łukasiewicza laboratorium badań i kalibracji labbikal ul. wincentego pola 2, 35-021 rzeszów laboratorium wzorcujące. wielkości mierzone: napięcie dc, prąd dc, napięcie ac, prąd ac, rezystancja dc. w stałej lokalizacji (s). ap 226 ap226 laboratorium wzorcujące wzorcowanie kalibracja dc voltage dc current ac voltage ac current dc resistance politechnika rzeszowska im. ignacego lukasiewicza laboratorium badan i kalibracji labbikal ul. wincentego pola 2, 35-021 rzeszow laboratorium wzorcujace. wielkosci mierzone: napiecie dc, prad dc, napiecie ac, prad ac, rezystancja dc. w stalej lokalizacji (s). ap 226 ap226 laboratorium wzorcujace wzorcowanie kalibracja dc voltage dc current ac voltage ac current dc resistance","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20226,podmiot.html","source_pdf_sha256":"1dc2ff0bdb92d6a2325e7a5214d32fe0628adb22f9dad76c185f614d2874a880","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/13/7650b65709da0abbbe3cc9d3a5cd9b47/AP%20226.pdf","status":"active","updated_at":"2026-11-13T12:00:00.000Z","valid_from":"13-03-2025","valid_until":"12-03-2029","website":"labbikal.prz.edu.pl","lab_division_en":"LABBiKAL Testing and Calibration Laboratory","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben.","has_de":true,"lab_division_de":"Prüf- und Kalibrierlabor LABBiKAL","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。","lab_division_zh":"LABBiKAL 检测和校准实验室","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny.","has_cs":true,"lab_division_cs":"Zkušební a kalibrační laboratoř LABBiKAL","pelny_cs":true},"methods":[{"_id":"0de54c6b94d105e5d0dc2152","lab_id":"6af7989a0ecd48de0c7068ac","country":"PL","accr_number":"AP 226","accr_body":"PCA","test_object":"Kalibratory\nKarty pomiarowe\nMierniki napięcia cyfrowe\nMultimetry\nZasilacze","test_object_en":"Calibrators\nData acquisition cards\nDigital voltmeters\nMultimeters\nPower supplies","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0 mV do 100 mV","cmc":"15 · 10⁻⁶ · U + 0,2 µV"},{"name":"","range":"0,1 V do 1 V","cmc":"5,8 · 10⁻⁶ · U + 0,3 µV"},{"name":"","range":"1 V do 10 V","cmc":"5,8 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"10 V do 100 V","cmc":"8,5 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V do 1000 V","cmc":"8,9 · 10⁻⁶ · U + 0,5 mV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"15 · 10⁻⁶ · U + 0,2 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"5,8 · 10⁻⁶ · U + 0,3 µV"},{"name":"","range":"1 V to 10 V","cmc":"5,8 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"10 V to 100 V","cmc":"8,5 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"8,9 · 10⁻⁶ · U + 0,5 mV"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0 mV do 100 mV CMC 15 · 10⁻⁶ · U + 0,2 µV\n0,1 V do 1 V CMC 5,8 · 10⁻⁶ · U + 0,3 µV\n1 V do 10 V CMC 5,8 · 10⁻⁶ · U + 0,5 µV\n10 V do 100 V CMC 8,5 · 10⁻⁶ · U + 30 µV\n100 V do 1000 V CMC 8,9 · 10⁻⁶ · U + 0,5 mV\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PW-01-1, PW-01-2, PW-01-3, PW-01-4 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PW-01-1","PW-01-2","PW-01-3","PW-01-4","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":false,"location_of_activity":"S","note":"U - wielkość mierzona (V)","note_en":"U - measured quantity (V)","search_text":"Kalibratory\nKarty pomiarowe\nMierniki napięcia cyfrowe\nMultimetry\nZasilacze Wzorcowanie — Napięcie DC\nZakres:\n0 mV do 100 mV CMC 15 · 10⁻⁶ · U + 0,2 µV\n0,1 V do 1 V CMC 5,8 · 10⁻⁶ · U + 0,3 µV\n1 V do 10 V CMC 5,8 · 10⁻⁶ · U + 0,5 µV\n10 V do 100 V CMC 8,5 · 10⁻⁶ · U + 30 µV\n100 V do 1000 V CMC 8,9 · 10⁻⁶ · U + 0,5 mV\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PW-01-1, PW-01-2, PW-01-3, PW-01-4 w oparciu o EURAMET cg-15 v.3.0 Kalibratory\nKarty pomiarowe\nMierniki napiecia cyfrowe\nMultimetry\nZasilacze Wzorcowanie — Napiecie DC\nZakres:\n0 mV do 100 mV CMC 15 · 10⁻⁶ · U + 0,2 µV\n0,1 V do 1 V CMC 5,8 · 10⁻⁶ · U + 0,3 µV\n1 V do 10 V CMC 5,8 · 10⁻⁶ · U + 0,5 µV\n10 V do 100 V CMC 8,5 · 10⁻⁶ · U + 30 µV\n100 V do 1000 V CMC 8,9 · 10⁻⁶ · U + 0,5 mV\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PW-01-1, PW-01-2, PW-01-3, PW-01-4 w oparciu o EURAMET cg-15 v.3.0","search_en":"Calibrators Data acquisition cards Digital voltmeters Multimeters Power supplies Calibration — DC voltage Internal procedure; Direct method; At permanent location (S) DC voltage Internal procedure Direct method At permanent location (S) PW-01-1, PW-01-2, PW-01-3, PW-01-4 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-01-1, PW-01-2, PW-01-3, PW-01-4 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0 mV to 100 mV","cmc":"15 · 10⁻⁶ · U + 0,2 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"5,8 · 10⁻⁶ · U + 0,3 µV"},{"name":"","range":"1 V to 10 V","cmc":"5,8 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"10 V to 100 V","cmc":"8,5 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"8,9 · 10⁻⁶ · U + 0,5 mV"}],"reference_de":"PW-01-1, PW-01-2, PW-01-3, PW-01-4 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"DC-Spannung","search_de":"Kalibratoren Messkarten Digitale Spannungsmessgeräte Multimeter Netzgeräte Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) PW-01-1, PW-01-2, PW-01-3, PW-01-4 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nMesskarten\nDigitale Spannungsmessgeräte\nMultimeter\nNetzgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0 mV to 100 mV","cmc":"15 · 10⁻⁶ · U + 0,2 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"5,8 · 10⁻⁶ · U + 0,3 µV"},{"name":"","range":"1 V to 10 V","cmc":"5,8 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"10 V to 100 V","cmc":"8,5 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"8,9 · 10⁻⁶ · U + 0,5 mV"}],"reference_zh":"PW-01-1, PW-01-2, PW-01-3, PW-01-4 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"直流电压","search_zh":"校准器 测量卡 数字电压表 万用表 电源 校准 — 直流电压 内部程序；直接法；在固定地点 (S) 直流电压 内部程序 直接法 在固定地点 (S) PW-01-1, PW-01-2, PW-01-3, PW-01-4 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"校准器\n测量卡\n数字电压表\n万用表\n电源","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0 mV to 100 mV","cmc":"15 · 10⁻⁶ · U + 0,2 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"5,8 · 10⁻⁶ · U + 0,3 µV"},{"name":"","range":"1 V to 10 V","cmc":"5,8 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"10 V to 100 V","cmc":"8,5 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"8,9 · 10⁻⁶ · U + 0,5 mV"}],"reference_cs":"PW-01-1, PW-01-2, PW-01-3, PW-01-4 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Napětí DC","search_cs":"Kalibrátory Měřicí karty Digitální měřiče napětí Multimetry Napájecí zdroje Kalibrace — Napětí DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Napětí DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) PW-01-1, PW-01-2, PW-01-3, PW-01-4 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nMěřicí karty\nDigitální měřiče napětí\nMultimetry\nNapájecí zdroje"},{"_id":"a09b8fdd503f8235499bf972","lab_id":"6af7989a0ecd48de0c7068ac","country":"PL","accr_number":"AP 226","accr_body":"PCA","test_object":"Kalibratory\nKarty pomiarowe\nMierniki prądu cyfrowe\nMultimetry\nZasilacze","test_object_en":"Calibrators\nData acquisition cards\nDigital ammeters\nMultimeters\nPower supplies","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0 µA do 10 µA","cmc":"40 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"10 µA do 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"0,1 mA do 1 mA","cmc":"14 · 10⁻⁶ · I + 4 nA"},{"name":"","range":"1 mA do 10 mA","cmc":"20 · 10⁻⁶ · I + 40 nA"},{"name":"","range":"10 mA do 100 mA","cmc":"86 · 10⁻⁶ · I + 1 µA"},{"name":"","range":"0,1 A do 1 A","cmc":"0,2 · 10⁻³ · I + 0,1 mA"},{"name":"","range":"1 A do 10 A","cmc":"0,35 · 10⁻³ · I + 0,4 mA"},{"name":"","range":"10 A do 20 A","cmc":"0,83 · 10⁻³ · I + 4,4 mA"}],"parameters_en":[{"name":"","range":"0 µA to 10 µA","cmc":"40 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"10 µA to 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"14 · 10⁻⁶ · I + 4 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"20 · 10⁻⁶ · I + 40 nA"},{"name":"","range":"10 mA to 100 mA","cmc":"86 · 10⁻⁶ · I + 1 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"0,2 · 10⁻³ · I + 0,1 mA"},{"name":"","range":"1 A to 10 A","cmc":"0,35 · 10⁻³ · I + 0,4 mA"},{"name":"","range":"10 A to 20 A","cmc":"0,83 · 10⁻³ · I + 4,4 mA"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0 µA do 10 µA CMC 40 · 10⁻⁶ · I + 0,4 nA\n10 µA do 100 µA CMC 15 · 10⁻⁶ · I + 0,4 nA\n0,1 mA do 1 mA CMC 14 · 10⁻⁶ · I + 4 nA\n1 mA do 10 mA CMC 20 · 10⁻⁶ · I + 40 nA\n10 mA do 100 mA CMC 86 · 10⁻⁶ · I + 1 µA\n0,1 A do 1 A CMC 0,2 · 10⁻³ · I + 0,1 mA\n1 A do 10 A CMC 0,35 · 10⁻³ · I + 0,4 mA\n10 A do 20 A CMC 0,83 · 10⁻³ · I + 4,4 mA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PW-01-1, PW-01-2, PW-01-3, PW-01-4 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PW-01-1","PW-01-2","PW-01-3","PW-01-4","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":"I – wielkość mierzona (A)","note_en":"I – measured quantity (A)","search_text":"Kalibratory\nKarty pomiarowe\nMierniki prądu cyfrowe\nMultimetry\nZasilacze Wzorcowanie — Prąd DC\nZakres:\n0 µA do 10 µA CMC 40 · 10⁻⁶ · I + 0,4 nA\n10 µA do 100 µA CMC 15 · 10⁻⁶ · I + 0,4 nA\n0,1 mA do 1 mA CMC 14 · 10⁻⁶ · I + 4 nA\n1 mA do 10 mA CMC 20 · 10⁻⁶ · I + 40 nA\n10 mA do 100 mA CMC 86 · 10⁻⁶ · I + 1 µA\n0,1 A do 1 A CMC 0,2 · 10⁻³ · I + 0,1 mA\n1 A do 10 A CMC 0,35 · 10⁻³ · I + 0,4 mA\n10 A do 20 A CMC 0,83 · 10⁻³ · I + 4,4 mA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PW-01-1, PW-01-2, PW-01-3, PW-01-4 w oparciu o EURAMET cg-15 v.3.0 Kalibratory\nKarty pomiarowe\nMierniki pradu cyfrowe\nMultimetry\nZasilacze Wzorcowanie — Prad DC\nZakres:\n0 µA do 10 µA CMC 40 · 10⁻⁶ · I + 0,4 nA\n10 µA do 100 µA CMC 15 · 10⁻⁶ · I + 0,4 nA\n0,1 mA do 1 mA CMC 14 · 10⁻⁶ · I + 4 nA\n1 mA do 10 mA CMC 20 · 10⁻⁶ · I + 40 nA\n10 mA do 100 mA CMC 86 · 10⁻⁶ · I + 1 µA\n0,1 A do 1 A CMC 0,2 · 10⁻³ · I + 0,1 mA\n1 A do 10 A CMC 0,35 · 10⁻³ · I + 0,4 mA\n10 A do 20 A CMC 0,83 · 10⁻³ · I + 4,4 mA\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PW-01-1, PW-01-2, PW-01-3, PW-01-4 w oparciu o EURAMET cg-15 v.3.0","search_en":"Calibrators Data acquisition cards Digital ammeters Multimeters Power supplies Calibration — DC current Internal procedure; Direct method; At permanent location (S) DC current Internal procedure Direct method At permanent location (S) PW-01-1, PW-01-2, PW-01-3, PW-01-4 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-01-1, PW-01-2, PW-01-3, PW-01-4 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0 µA to 10 µA","cmc":"40 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"10 µA to 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"14 · 10⁻⁶ · I + 4 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"20 · 10⁻⁶ · I + 40 nA"},{"name":"","range":"10 mA bis 100 mA","cmc":"86 · 10⁻⁶ · I + 1 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"0,2 · 10⁻³ · I + 0,1 mA"},{"name":"","range":"1 A to 10 A","cmc":"0,35 · 10⁻³ · I + 0,4 mA"},{"name":"","range":"10 A to 20 A","cmc":"0,83 · 10⁻³ · I + 4,4 mA"}],"reference_de":"PW-01-1, PW-01-2, PW-01-3, PW-01-4 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"DC-Strom","search_de":"Kalibratoren Messkarten Digitale Strommessgeräte Multimeter Netzgeräte Kalibrierung — DC-Strom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) PW-01-1, PW-01-2, PW-01-3, PW-01-4 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nMesskarten\nDigitale Strommessgeräte\nMultimeter\nNetzgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0 µA to 10 µA","cmc":"40 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"10 µA to 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"14 · 10⁻⁶ · I + 4 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"20 · 10⁻⁶ · I + 40 nA"},{"name":"","range":"10 mA to 100 mA","cmc":"86 · 10⁻⁶ · I + 1 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"0,2 · 10⁻³ · I + 0,1 mA"},{"name":"","range":"1 A to 10 A","cmc":"0,35 · 10⁻³ · I + 0,4 mA"},{"name":"","range":"10 A to 20 A","cmc":"0,83 · 10⁻³ · I + 4,4 mA"}],"reference_zh":"PW-01-1, PW-01-2, PW-01-3, PW-01-4 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"直流电流","search_zh":"校准器 测量卡 数字电流表 万用表 电源 校准 — 直流电流 内部程序；直接法；在固定地点 (S) 直流电流 内部程序 直接法 在固定地点 (S) PW-01-1, PW-01-2, PW-01-3, PW-01-4 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"校准器\n测量卡\n数字电流表\n万用表\n电源","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0 µA to 10 µA","cmc":"40 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"10 µA to 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"14 · 10⁻⁶ · I + 4 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"20 · 10⁻⁶ · I + 40 nA"},{"name":"","range":"10 mA to 100 mA","cmc":"86 · 10⁻⁶ · I + 1 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"0,2 · 10⁻³ · I + 0,1 mA"},{"name":"","range":"1 A to 10 A","cmc":"0,35 · 10⁻³ · I + 0,4 mA"},{"name":"","range":"10 A to 20 A","cmc":"0,83 · 10⁻³ · I + 4,4 mA"}],"reference_cs":"PW-01-1, PW-01-2, PW-01-3, PW-01-4 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Proud DC","search_cs":"Kalibrátory Měřicí karty Digitální měřiče proudu Multimetry Napájecí zdroje Kalibrace — Proud DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Proud DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) PW-01-1, PW-01-2, PW-01-3, PW-01-4 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nMěřicí karty\nDigitální měřiče proudu\nMultimetry\nNapájecí zdroje"},{"_id":"ab7bb1df628b58ebd6052104","lab_id":"6af7989a0ecd48de0c7068ac","country":"PL","accr_number":"AP 226","accr_body":"PCA","test_object":"Kalibratory\nKarty pomiarowe\nMierniki napięcia cyfrowe\nMultimetry","test_object_en":"Calibrators\nData acquisition cards\nDigital voltmeters\nMultimeters","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"10 Hz do 2 kHz","range":"1 mV do 10 mV","cmc":"0,33 · 10⁻³ · U + 1,1 µV"},{"name":"2 kHz do 10 kHz","range":"1 mV do 10 mV","cmc":"0,48 · 10⁻³ · U + 1,1 µV"},{"name":"10 kHz do 30 kHz","range":"1 mV do 10 mV","cmc":"0,49 · 10⁻³ · U + 1,1 µV"},{"name":"30 kHz do 100 kHz","range":"1 mV do 10 mV","cmc":"3,5 · 10⁻³ · U + 1,1 µV"},{"name":"10 Hz do 2 kHz","range":"10 mV do 100 mV","cmc":"0,13 · 10⁻³ · U + 0,5 µV"},{"name":"2 kHz do 10 kHz","range":"10 mV do 100 mV","cmc":"0,2 · 10⁻³ · U + 0,5 µV"},{"name":"10 kHz do 30 kHz","range":"10 mV do 100 mV","cmc":"0,38 · 10⁻³ · U + 1 µV"},{"name":"30 kHz do 100 kHz","range":"10 mV do 100 mV","cmc":"0,92 · 10⁻³ · U + 5 µV"},{"name":"10 Hz do 2 kHz","range":"0,1 V do 1 V","cmc":"0,12 · 10⁻³ · U + 5 µV"},{"name":"2 kHz do 10 kHz","range":"0,1 V do 1 V","cmc":"0,19 · 10⁻³ · U + 5 µV"},{"name":"10 kHz do 30 kHz","range":"0,1 V do 1 V","cmc":"0,38 · 10⁻³ · U + 10 µV"},{"name":"30 kHz do 100 kHz","range":"0,1 V do 1 V","cmc":"0,92 · 10⁻³ · U + 50 µV"},{"name":"10 Hz do 2 kHz","range":"1 V do 10 V","cmc":"0,12 · 10⁻³ · U + 0,05 mV"},{"name":"2 kHz do 10 kHz","range":"1 V do 10 V","cmc":"0,19 · 10⁻³ · U + 0,05 mV"},{"name":"10 kHz do 30 kHz","range":"1 V do 10 V","cmc":"0,38 · 10⁻³ · U + 0,1 mV"},{"name":"30 kHz do 100 kHz","range":"1 V do 10 V","cmc":"0,92 · 10⁻³ · U + 0,5 mV"},{"name":"10 Hz do 2 kHz","range":"10 V do 33 V","cmc":"0,13 · 10⁻³ · U + 0,5 mV"},{"name":"2 kHz do 10 kHz","range":"10 V do 33 V","cmc":"0,16 · 10⁻³ · U + 0,5 mV"},{"name":"10 kHz do 30 kHz","range":"10 V do 33 V","cmc":"0,38 · 10⁻³ · U + 1 mV"},{"name":"30 kHz do 100 kHz","range":"10 V do 33 V","cmc":"0,98 · 10⁻³ · U + 5 mV"},{"name":"45 Hz do 2 kHz","range":"33 V do 100 V","cmc":"0,13 · 10⁻³ · U + 0,5 mV"},{"name":"2 kHz do 10 kHz","range":"33 V do 100 V","cmc":"0,16 · 10⁻³ · U + 0,5 mV"},{"name":"10 kHz do 30 kHz","range":"33 V do 100 V","cmc":"0,38 · 10⁻³ · U + 1 mV"},{"name":"30 kHz do 100 kHz","range":"33 V do 100 V","cmc":"0,98 · 10⁻³ · U + 5 mV"},{"name":"45 Hz do 2 kHz","range":"100 V do 330 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"2 kHz do 10 kHz","range":"100 V do 330 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"10 kHz do 30 kHz","range":"100 V do 330 V","cmc":"0,38 · 10⁻³ · U + 25 mV"},{"name":"30 kHz do 100 kHz","range":"100 V do 330 V","cmc":"0,98 · 10⁻³ · U + 0,1 V"},{"name":"45 Hz do 2 kHz","range":"330 V do 1000 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"2 kHz do 10 kHz","range":"330 V do 1000 V","cmc":"0,16 · 10⁻³ · U + 25 mV"}],"parameters_en":[{"name":"10 Hz to 2 kHz","range":"1 mV to 10 mV","cmc":"0,33 · 10⁻³ · U + 1,1 µV"},{"name":"2 kHz to 10 kHz","range":"1 mV to 10 mV","cmc":"0,48 · 10⁻³ · U + 1,1 µV"},{"name":"10 kHz to 30 kHz","range":"1 mV to 10 mV","cmc":"0,49 · 10⁻³ · U + 1,1 µV"},{"name":"30 kHz to 100 kHz","range":"1 mV to 10 mV","cmc":"3,5 · 10⁻³ · U + 1,1 µV"},{"name":"10 Hz to 2 kHz","range":"10 mV to 100 mV","cmc":"0,13 · 10⁻³ · U + 0,5 µV"},{"name":"2 kHz to 10 kHz","range":"10 mV to 100 mV","cmc":"0,2 · 10⁻³ · U + 0,5 µV"},{"name":"10 kHz to 30 kHz","range":"10 mV to 100 mV","cmc":"0,38 · 10⁻³ · U + 1 µV"},{"name":"30 kHz to 100 kHz","range":"10 mV to 100 mV","cmc":"0,92 · 10⁻³ · U + 5 µV"},{"name":"10 Hz to 2 kHz","range":"0,1 V to 1 V","cmc":"0,12 · 10⁻³ · U + 5 µV"},{"name":"2 kHz to 10 kHz","range":"0,1 V to 1 V","cmc":"0,19 · 10⁻³ · U + 5 µV"},{"name":"10 kHz to 30 kHz","range":"0,1 V to 1 V","cmc":"0,38 · 10⁻³ · U + 10 µV"},{"name":"30 kHz to 100 kHz","range":"0,1 V to 1 V","cmc":"0,92 · 10⁻³ · U + 50 µV"},{"name":"10 Hz to 2 kHz","range":"1 V to 10 V","cmc":"0,12 · 10⁻³ · U + 0,05 mV"},{"name":"2 kHz to 10 kHz","range":"1 V to 10 V","cmc":"0,19 · 10⁻³ · U + 0,05 mV"},{"name":"10 kHz to 30 kHz","range":"1 V to 10 V","cmc":"0,38 · 10⁻³ · U + 0,1 mV"},{"name":"30 kHz to 100 kHz","range":"1 V to 10 V","cmc":"0,92 · 10⁻³ · U + 0,5 mV"},{"name":"10 Hz to 2 kHz","range":"10 V to 33 V","cmc":"0,13 · 10⁻³ · U + 0,5 mV"},{"name":"2 kHz to 10 kHz","range":"10 V to 33 V","cmc":"0,16 · 10⁻³ · U + 0,5 mV"},{"name":"10 kHz to 30 kHz","range":"10 V to 33 V","cmc":"0,38 · 10⁻³ · U + 1 mV"},{"name":"30 kHz to 100 kHz","range":"10 V to 33 V","cmc":"0,98 · 10⁻³ · U + 5 mV"},{"name":"45 Hz to 2 kHz","range":"33 V to 100 V","cmc":"0,13 · 10⁻³ · U + 0,5 mV"},{"name":"2 kHz to 10 kHz","range":"33 V to 100 V","cmc":"0,16 · 10⁻³ · U + 0,5 mV"},{"name":"10 kHz to 30 kHz","range":"33 V to 100 V","cmc":"0,38 · 10⁻³ · U + 1 mV"},{"name":"30 kHz to 100 kHz","range":"33 V to 100 V","cmc":"0,98 · 10⁻³ · U + 5 mV"},{"name":"45 Hz to 2 kHz","range":"100 V to 330 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"2 kHz to 10 kHz","range":"100 V to 330 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"10 kHz to 30 kHz","range":"100 V to 330 V","cmc":"0,38 · 10⁻³ · U + 25 mV"},{"name":"30 kHz to 100 kHz","range":"100 V to 330 V","cmc":"0,98 · 10⁻³ · U + 0,1 V"},{"name":"45 Hz to 2 kHz","range":"330 V to 1000 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"2 kHz to 10 kHz","range":"330 V to 1000 V","cmc":"0,16 · 10⁻³ · U + 25 mV"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 2 kHz 1 mV do 10 mV CMC 0,33 · 10⁻³ · U + 1,1 µV\n2 kHz do 10 kHz 1 mV do 10 mV CMC 0,48 · 10⁻³ · U + 1,1 µV\n10 kHz do 30 kHz 1 mV do 10 mV CMC 0,49 · 10⁻³ · U + 1,1 µV\n30 kHz do 100 kHz 1 mV do 10 mV CMC 3,5 · 10⁻³ · U + 1,1 µV\n10 Hz do 2 kHz 10 mV do 100 mV CMC 0,13 · 10⁻³ · U + 0,5 µV\n2 kHz do 10 kHz 10 mV do 100 mV CMC 0,2 · 10⁻³ · U + 0,5 µV\n10 kHz do 30 kHz 10 mV do 100 mV CMC 0,38 · 10⁻³ · U + 1 µV\n30 kHz do 100 kHz 10 mV do 100 mV CMC 0,92 · 10⁻³ · U + 5 µV\n10 Hz do 2 kHz 0,1 V do 1 V CMC 0,12 · 10⁻³ · U + 5 µV\n2 kHz do 10 kHz 0,1 V do 1 V CMC 0,19 · 10⁻³ · U + 5 µV\n10 kHz do 30 kHz 0,1 V do 1 V CMC 0,38 · 10⁻³ · U + 10 µV\n30 kHz do 100 kHz 0,1 V do 1 V CMC 0,92 · 10⁻³ · U + 50 µV\n10 Hz do 2 kHz 1 V do 10 V CMC 0,12 · 10⁻³ · U + 0,05 mV\n2 kHz do 10 kHz 1 V do 10 V CMC 0,19 · 10⁻³ · U + 0,05 mV\n10 kHz do 30 kHz 1 V do 10 V CMC 0,38 · 10⁻³ · U + 0,1 mV\n30 kHz do 100 kHz 1 V do 10 V CMC 0,92 · 10⁻³ · U + 0,5 mV\n10 Hz do 2 kHz 10 V do 33 V CMC 0,13 · 10⁻³ · U + 0,5 mV\n2 kHz do 10 kHz 10 V do 33 V CMC 0,16 · 10⁻³ · U + 0,5 mV\n10 kHz do 30 kHz 10 V do 33 V CMC 0,38 · 10⁻³ · U + 1 mV\n30 kHz do 100 kHz 10 V do 33 V CMC 0,98 · 10⁻³ · U + 5 mV\n45 Hz do 2 kHz 33 V do 100 V CMC 0,13 · 10⁻³ · U + 0,5 mV\n2 kHz do 10 kHz 33 V do 100 V CMC 0,16 · 10⁻³ · U + 0,5 mV\n10 kHz do 30 kHz 33 V do 100 V CMC 0,38 · 10⁻³ · U + 1 mV\n30 kHz do 100 kHz 33 V do 100 V CMC 0,98 · 10⁻³ · U + 5 mV\n45 Hz do 2 kHz 100 V do 330 V CMC 0,16 · 10⁻³ · U + 25 mV\n2 kHz do 10 kHz 100 V do 330 V CMC 0,16 · 10⁻³ · U + 25 mV\n10 kHz do 30 kHz 100 V do 330 V CMC 0,38 · 10⁻³ · U + 25 mV\n30 kHz do 100 kHz 100 V do 330 V CMC 0,98 · 10⁻³ · U + 0,1 V\n45 Hz do 2 kHz 330 V do 1000 V CMC 0,16 · 10⁻³ · U + 25 mV\n2 kHz do 10 kHz 330 V do 1000 V CMC 0,16 · 10⁻³ · U + 25 mV\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PW-01-1, PW-01-2, PW-01-4 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PW-01-1","PW-01-2","PW-01-4","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":false,"location_of_activity":"S","note":"U - wielkość mierzona (V)","note_en":"U - measured quantity (V)","search_text":"Kalibratory\nKarty pomiarowe\nMierniki napięcia cyfrowe\nMultimetry Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 2 kHz 1 mV do 10 mV CMC 0,33 · 10⁻³ · U + 1,1 µV\n2 kHz do 10 kHz 1 mV do 10 mV CMC 0,48 · 10⁻³ · U + 1,1 µV\n10 kHz do 30 kHz 1 mV do 10 mV CMC 0,49 · 10⁻³ · U + 1,1 µV\n30 kHz do 100 kHz 1 mV do 10 mV CMC 3,5 · 10⁻³ · U + 1,1 µV\n10 Hz do 2 kHz 10 mV do 100 mV CMC 0,13 · 10⁻³ · U + 0,5 µV\n2 kHz do 10 kHz 10 mV do 100 mV CMC 0,2 · 10⁻³ · U + 0,5 µV\n10 kHz do 30 kHz 10 mV do 100 mV CMC 0,38 · 10⁻³ · U + 1 µV\n30 kHz do 100 kHz 10 mV do 100 mV CMC 0,92 · 10⁻³ · U + 5 µV\n10 Hz do 2 kHz 0,1 V do 1 V CMC 0,12 · 10⁻³ · U + 5 µV\n2 kHz do 10 kHz 0,1 V do 1 V CMC 0,19 · 10⁻³ · U + 5 µV\n10 kHz do 30 kHz 0,1 V do 1 V CMC 0,38 · 10⁻³ · U + 10 µV\n30 kHz do 100 kHz 0,1 V do 1 V CMC 0,92 · 10⁻³ · U + 50 µV\n10 Hz do 2 kHz 1 V do 10 V CMC 0,12 · 10⁻³ · U + 0,05 mV\n2 kHz do 10 kHz 1 V do 10 V CMC 0,19 · 10⁻³ · U + 0,05 mV\n10 kHz do 30 kHz 1 V do 10 V CMC 0,38 · 10⁻³ · U + 0,1 mV\n30 kHz do 100 kHz 1 V do 10 V CMC 0,92 · 10⁻³ · U + 0,5 mV\n10 Hz do 2 kHz 10 V do 33 V CMC 0,13 · 10⁻³ · U + 0,5 mV\n2 kHz do 10 kHz 10 V do 33 V CMC 0,16 · 10⁻³ · U + 0,5 mV\n10 kHz do 30 kHz 10 V do 33 V CMC 0,38 · 10⁻³ · U + 1 mV\n30 kHz do 100 kHz 10 V do 33 V CMC 0,98 · 10⁻³ · U + 5 mV\n45 Hz do 2 kHz 33 V do 100 V CMC 0,13 · 10⁻³ · U + 0,5 mV\n2 kHz do 10 kHz 33 V do 100 V CMC 0,16 · 10⁻³ · U + 0,5 mV\n10 kHz do 30 kHz 33 V do 100 V CMC 0,38 · 10⁻³ · U + 1 mV\n30 kHz do 100 kHz 33 V do 100 V CMC 0,98 · 10⁻³ · U + 5 mV\n45 Hz do 2 kHz 100 V do 330 V CMC 0,16 · 10⁻³ · U + 25 mV\n2 kHz do 10 kHz 100 V do 330 V CMC 0,16 · 10⁻³ · U + 25 mV\n10 kHz do 30 kHz 100 V do 330 V CMC 0,38 · 10⁻³ · U + 25 mV\n30 kHz do 100 kHz 100 V do 330 V CMC 0,98 · 10⁻³ · U + 0,1 V\n45 Hz do 2 kHz 330 V do 1000 V CMC 0,16 · 10⁻³ · U + 25 mV\n2 kHz do 10 kHz 330 V do 1000 V CMC 0,16 · 10⁻³ · U + 25 mV\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PW-01-1, PW-01-2, PW-01-4 w oparciu o EURAMET cg-15 v.3.0 Kalibratory\nKarty pomiarowe\nMierniki napiecia cyfrowe\nMultimetry Wzorcowanie — Napiecie AC\nZakres:\n10 Hz do 2 kHz 1 mV do 10 mV CMC 0,33 · 10⁻³ · U + 1,1 µV\n2 kHz do 10 kHz 1 mV do 10 mV CMC 0,48 · 10⁻³ · U + 1,1 µV\n10 kHz do 30 kHz 1 mV do 10 mV CMC 0,49 · 10⁻³ · U + 1,1 µV\n30 kHz do 100 kHz 1 mV do 10 mV CMC 3,5 · 10⁻³ · U + 1,1 µV\n10 Hz do 2 kHz 10 mV do 100 mV CMC 0,13 · 10⁻³ · U + 0,5 µV\n2 kHz do 10 kHz 10 mV do 100 mV CMC 0,2 · 10⁻³ · U + 0,5 µV\n10 kHz do 30 kHz 10 mV do 100 mV CMC 0,38 · 10⁻³ · U + 1 µV\n30 kHz do 100 kHz 10 mV do 100 mV CMC 0,92 · 10⁻³ · U + 5 µV\n10 Hz do 2 kHz 0,1 V do 1 V CMC 0,12 · 10⁻³ · U + 5 µV\n2 kHz do 10 kHz 0,1 V do 1 V CMC 0,19 · 10⁻³ · U + 5 µV\n10 kHz do 30 kHz 0,1 V do 1 V CMC 0,38 · 10⁻³ · U + 10 µV\n30 kHz do 100 kHz 0,1 V do 1 V CMC 0,92 · 10⁻³ · U + 50 µV\n10 Hz do 2 kHz 1 V do 10 V CMC 0,12 · 10⁻³ · U + 0,05 mV\n2 kHz do 10 kHz 1 V do 10 V CMC 0,19 · 10⁻³ · U + 0,05 mV\n10 kHz do 30 kHz 1 V do 10 V CMC 0,38 · 10⁻³ · U + 0,1 mV\n30 kHz do 100 kHz 1 V do 10 V CMC 0,92 · 10⁻³ · U + 0,5 mV\n10 Hz do 2 kHz 10 V do 33 V CMC 0,13 · 10⁻³ · U + 0,5 mV\n2 kHz do 10 kHz 10 V do 33 V CMC 0,16 · 10⁻³ · U + 0,5 mV\n10 kHz do 30 kHz 10 V do 33 V CMC 0,38 · 10⁻³ · U + 1 mV\n30 kHz do 100 kHz 10 V do 33 V CMC 0,98 · 10⁻³ · U + 5 mV\n45 Hz do 2 kHz 33 V do 100 V CMC 0,13 · 10⁻³ · U + 0,5 mV\n2 kHz do 10 kHz 33 V do 100 V CMC 0,16 · 10⁻³ · U + 0,5 mV\n10 kHz do 30 kHz 33 V do 100 V CMC 0,38 · 10⁻³ · U + 1 mV\n30 kHz do 100 kHz 33 V do 100 V CMC 0,98 · 10⁻³ · U + 5 mV\n45 Hz do 2 kHz 100 V do 330 V CMC 0,16 · 10⁻³ · U + 25 mV\n2 kHz do 10 kHz 100 V do 330 V CMC 0,16 · 10⁻³ · U + 25 mV\n10 kHz do 30 kHz 100 V do 330 V CMC 0,38 · 10⁻³ · U + 25 mV\n30 kHz do 100 kHz 100 V do 330 V CMC 0,98 · 10⁻³ · U + 0,1 V\n45 Hz do 2 kHz 330 V do 1000 V CMC 0,16 · 10⁻³ · U + 25 mV\n2 kHz do 10 kHz 330 V do 1000 V CMC 0,16 · 10⁻³ · U + 25 mV\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PW-01-1, PW-01-2, PW-01-4 w oparciu o EURAMET cg-15 v.3.0","search_en":"Calibrators Data acquisition cards Digital voltmeters Multimeters Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) AC voltage Internal procedure Direct method At permanent location (S) 10 Hz to 2 kHz 2 kHz to 10 kHz 10 kHz to 30 kHz 30 kHz to 100 kHz 10 Hz to 2 kHz 2 kHz to 10 kHz 10 kHz to 30 kHz 30 kHz to 100 kHz 10 Hz to 2 kHz 2 kHz to 10 kHz 10 kHz to 30 kHz 30 kHz to 100 kHz 10 Hz to 2 kHz 2 kHz to 10 kHz 10 kHz to 30 kHz 30 kHz to 100 kHz 10 Hz to 2 kHz 2 kHz to 10 kHz 10 kHz to 30 kHz 30 kHz to 100 kHz 45 Hz to 2 kHz 2 kHz to 10 kHz 10 kHz to 30 kHz 30 kHz to 100 kHz 45 Hz to 2 kHz 2 kHz to 10 kHz 10 kHz to 30 kHz 30 kHz to 100 kHz 45 Hz to 2 kHz 2 kHz to 10 kHz PW-01-1, PW-01-2, PW-01-4 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-01-1, PW-01-2, PW-01-4 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"10 Hz bis 2 kHz","range":"1 mV to 10 mV","cmc":"0,33 · 10⁻³ · U + 1,1 µV"},{"name":"2 kHz bis 10 kHz","range":"1 mV to 10 mV","cmc":"0,48 · 10⁻³ · U + 1,1 µV"},{"name":"10 kHz bis 30 kHz","range":"1 mV to 10 mV","cmc":"0,49 · 10⁻³ · U + 1,1 µV"},{"name":"30 kHz bis 100 kHz","range":"1 mV to 10 mV","cmc":"3,5 · 10⁻³ · U + 1,1 µV"},{"name":"10 Hz bis 2 kHz","range":"10 mV to 100 mV","cmc":"0,13 · 10⁻³ · U + 0,5 µV"},{"name":"2 kHz bis 10 kHz","range":"10 mV to 100 mV","cmc":"0,2 · 10⁻³ · U + 0,5 µV"},{"name":"10 kHz bis 30 kHz","range":"10 mV to 100 mV","cmc":"0,38 · 10⁻³ · U + 1 µV"},{"name":"30 kHz bis 100 kHz","range":"10 mV to 100 mV","cmc":"0,92 · 10⁻³ · U + 5 µV"},{"name":"10 Hz bis 2 kHz","range":"0,1 V to 1 V","cmc":"0,12 · 10⁻³ · U + 5 µV"},{"name":"2 kHz bis 10 kHz","range":"0,1 V to 1 V","cmc":"0,19 · 10⁻³ · U + 5 µV"},{"name":"10 kHz bis 30 kHz","range":"0,1 V to 1 V","cmc":"0,38 · 10⁻³ · U + 10 µV"},{"name":"30 kHz bis 100 kHz","range":"0,1 V to 1 V","cmc":"0,92 · 10⁻³ · U + 50 µV"},{"name":"10 Hz bis 2 kHz","range":"1 V to 10 V","cmc":"0,12 · 10⁻³ · U + 0,05 mV"},{"name":"2 kHz bis 10 kHz","range":"1 V to 10 V","cmc":"0,19 · 10⁻³ · U + 0,05 mV"},{"name":"10 kHz bis 30 kHz","range":"1 V to 10 V","cmc":"0,38 · 10⁻³ · U + 0,1 mV"},{"name":"30 kHz bis 100 kHz","range":"1 V to 10 V","cmc":"0,92 · 10⁻³ · U + 0,5 mV"},{"name":"10 Hz bis 2 kHz","range":"10 V to 33 V","cmc":"0,13 · 10⁻³ · U + 0,5 mV"},{"name":"2 kHz bis 10 kHz","range":"10 V to 33 V","cmc":"0,16 · 10⁻³ · U + 0,5 mV"},{"name":"10 kHz bis 30 kHz","range":"10 V to 33 V","cmc":"0,38 · 10⁻³ · U + 1 mV"},{"name":"30 kHz bis 100 kHz","range":"10 V to 33 V","cmc":"0,98 · 10⁻³ · U + 5 mV"},{"name":"45 Hz bis 2 kHz","range":"33 V to 100 V","cmc":"0,13 · 10⁻³ · U + 0,5 mV"},{"name":"2 kHz bis 10 kHz","range":"33 V to 100 V","cmc":"0,16 · 10⁻³ · U + 0,5 mV"},{"name":"10 kHz bis 30 kHz","range":"33 V to 100 V","cmc":"0,38 · 10⁻³ · U + 1 mV"},{"name":"30 kHz bis 100 kHz","range":"33 V to 100 V","cmc":"0,98 · 10⁻³ · U + 5 mV"},{"name":"45 Hz bis 2 kHz","range":"100 V to 330 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"2 kHz bis 10 kHz","range":"100 V to 330 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"10 kHz bis 30 kHz","range":"100 V to 330 V","cmc":"0,38 · 10⁻³ · U + 25 mV"},{"name":"30 kHz bis 100 kHz","range":"100 V to 330 V","cmc":"0,98 · 10⁻³ · U + 0,1 V"},{"name":"45 Hz bis 2 kHz","range":"330 V to 1000 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"2 kHz bis 10 kHz","range":"330 V to 1000 V","cmc":"0,16 · 10⁻³ · U + 25 mV"}],"reference_de":"PW-01-1, PW-01-2, PW-01-4 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"AC-Spannung","search_de":"Kalibratoren Messkarten Digitale Spannungsmessgeräte Multimeter Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) 10 Hz bis 2 kHz 2 kHz bis 10 kHz 10 kHz bis 30 kHz 30 kHz bis 100 kHz 10 Hz bis 2 kHz 2 kHz bis 10 kHz 10 kHz bis 30 kHz 30 kHz bis 100 kHz 10 Hz bis 2 kHz 2 kHz bis 10 kHz 10 kHz bis 30 kHz 30 kHz bis 100 kHz 10 Hz bis 2 kHz 2 kHz bis 10 kHz 10 kHz bis 30 kHz 30 kHz bis 100 kHz 10 Hz bis 2 kHz 2 kHz bis 10 kHz 10 kHz bis 30 kHz 30 kHz bis 100 kHz 45 Hz bis 2 kHz 2 kHz bis 10 kHz 10 kHz bis 30 kHz 30 kHz bis 100 kHz 45 Hz bis 2 kHz 2 kHz bis 10 kHz 10 kHz bis 30 kHz 30 kHz bis 100 kHz 45 Hz bis 2 kHz 2 kHz bis 10 kHz PW-01-1, PW-01-2, PW-01-4 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nMesskarten\nDigitale Spannungsmessgeräte\nMultimeter","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"10 Hz 至 2 kHz","range":"1 mV to 10 mV","cmc":"0,33 · 10⁻³ · U + 1,1 µV"},{"name":"2 kHz 至 10 kHz","range":"1 mV to 10 mV","cmc":"0,48 · 10⁻³ · U + 1,1 µV"},{"name":"10 kHz 至 30 kHz","range":"1 mV to 10 mV","cmc":"0,49 · 10⁻³ · U + 1,1 µV"},{"name":"30 kHz 至 100 kHz","range":"1 mV to 10 mV","cmc":"3,5 · 10⁻³ · U + 1,1 µV"},{"name":"10 Hz 至 2 kHz","range":"10 mV to 100 mV","cmc":"0,13 · 10⁻³ · U + 0,5 µV"},{"name":"2 kHz 至 10 kHz","range":"10 mV to 100 mV","cmc":"0,2 · 10⁻³ · U + 0,5 µV"},{"name":"10 kHz 至 30 kHz","range":"10 mV to 100 mV","cmc":"0,38 · 10⁻³ · U + 1 µV"},{"name":"30 kHz 至 100 kHz","range":"10 mV to 100 mV","cmc":"0,92 · 10⁻³ · U + 5 µV"},{"name":"10 Hz 至 2 kHz","range":"0,1 V to 1 V","cmc":"0,12 · 10⁻³ · U + 5 µV"},{"name":"2 kHz 至 10 kHz","range":"0,1 V to 1 V","cmc":"0,19 · 10⁻³ · U + 5 µV"},{"name":"10 kHz 至 30 kHz","range":"0,1 V to 1 V","cmc":"0,38 · 10⁻³ · U + 10 µV"},{"name":"30 kHz 至 100 kHz","range":"0,1 V to 1 V","cmc":"0,92 · 10⁻³ · U + 50 µV"},{"name":"10 Hz 至 2 kHz","range":"1 V to 10 V","cmc":"0,12 · 10⁻³ · U + 0,05 mV"},{"name":"2 kHz 至 10 kHz","range":"1 V to 10 V","cmc":"0,19 · 10⁻³ · U + 0,05 mV"},{"name":"10 kHz 至 30 kHz","range":"1 V to 10 V","cmc":"0,38 · 10⁻³ · U + 0,1 mV"},{"name":"30 kHz 至 100 kHz","range":"1 V to 10 V","cmc":"0,92 · 10⁻³ · U + 0,5 mV"},{"name":"10 Hz 至 2 kHz","range":"10 V to 33 V","cmc":"0,13 · 10⁻³ · U + 0,5 mV"},{"name":"2 kHz 至 10 kHz","range":"10 V to 33 V","cmc":"0,16 · 10⁻³ · U + 0,5 mV"},{"name":"10 kHz 至 30 kHz","range":"10 V to 33 V","cmc":"0,38 · 10⁻³ · U + 1 mV"},{"name":"30 kHz 至 100 kHz","range":"10 V to 33 V","cmc":"0,98 · 10⁻³ · U + 5 mV"},{"name":"45 Hz 至 2 kHz","range":"33 V to 100 V","cmc":"0,13 · 10⁻³ · U + 0,5 mV"},{"name":"2 kHz 至 10 kHz","range":"33 V to 100 V","cmc":"0,16 · 10⁻³ · U + 0,5 mV"},{"name":"10 kHz 至 30 kHz","range":"33 V to 100 V","cmc":"0,38 · 10⁻³ · U + 1 mV"},{"name":"30 kHz 至 100 kHz","range":"33 V to 100 V","cmc":"0,98 · 10⁻³ · U + 5 mV"},{"name":"45 Hz 至 2 kHz","range":"100 V to 330 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"2 kHz 至 10 kHz","range":"100 V to 330 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"10 kHz 至 30 kHz","range":"100 V to 330 V","cmc":"0,38 · 10⁻³ · U + 25 mV"},{"name":"30 kHz 至 100 kHz","range":"100 V to 330 V","cmc":"0,98 · 10⁻³ · U + 0,1 V"},{"name":"45 Hz 至 2 kHz","range":"330 V to 1000 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"2 kHz 至 10 kHz","range":"330 V to 1000 V","cmc":"0,16 · 10⁻³ · U + 25 mV"}],"reference_zh":"PW-01-1, PW-01-2, PW-01-4 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"交流电压","search_zh":"校准器 测量卡 数字电压表 万用表 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 交流电压 内部程序 直接法 在固定地点 (S) 10 Hz 至 2 kHz 2 kHz 至 10 kHz 10 kHz 至 30 kHz 30 kHz 至 100 kHz 10 Hz 至 2 kHz 2 kHz 至 10 kHz 10 kHz 至 30 kHz 30 kHz 至 100 kHz 10 Hz 至 2 kHz 2 kHz 至 10 kHz 10 kHz 至 30 kHz 30 kHz 至 100 kHz 10 Hz 至 2 kHz 2 kHz 至 10 kHz 10 kHz 至 30 kHz 30 kHz 至 100 kHz 10 Hz 至 2 kHz 2 kHz 至 10 kHz 10 kHz 至 30 kHz 30 kHz 至 100 kHz 45 Hz 至 2 kHz 2 kHz 至 10 kHz 10 kHz 至 30 kHz 30 kHz 至 100 kHz 45 Hz 至 2 kHz 2 kHz 至 10 kHz 10 kHz 至 30 kHz 30 kHz 至 100 kHz 45 Hz 至 2 kHz 2 kHz 至 10 kHz PW-01-1, PW-01-2, PW-01-4 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"校准器\n测量卡\n数字电压表\n万用表","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"10 Hz až 2 kHz","range":"1 mV to 10 mV","cmc":"0,33 · 10⁻³ · U + 1,1 µV"},{"name":"2 kHz až 10 kHz","range":"1 mV to 10 mV","cmc":"0,48 · 10⁻³ · U + 1,1 µV"},{"name":"10 kHz až 30 kHz","range":"1 mV to 10 mV","cmc":"0,49 · 10⁻³ · U + 1,1 µV"},{"name":"30 kHz až 100 kHz","range":"1 mV to 10 mV","cmc":"3,5 · 10⁻³ · U + 1,1 µV"},{"name":"10 Hz až 2 kHz","range":"10 mV to 100 mV","cmc":"0,13 · 10⁻³ · U + 0,5 µV"},{"name":"2 kHz až 10 kHz","range":"10 mV to 100 mV","cmc":"0,2 · 10⁻³ · U + 0,5 µV"},{"name":"10 kHz až 30 kHz","range":"10 mV to 100 mV","cmc":"0,38 · 10⁻³ · U + 1 µV"},{"name":"30 kHz až 100 kHz","range":"10 mV to 100 mV","cmc":"0,92 · 10⁻³ · U + 5 µV"},{"name":"10 Hz až 2 kHz","range":"0,1 V to 1 V","cmc":"0,12 · 10⁻³ · U + 5 µV"},{"name":"2 kHz až 10 kHz","range":"0,1 V to 1 V","cmc":"0,19 · 10⁻³ · U + 5 µV"},{"name":"10 kHz až 30 kHz","range":"0,1 V to 1 V","cmc":"0,38 · 10⁻³ · U + 10 µV"},{"name":"30 kHz až 100 kHz","range":"0,1 V to 1 V","cmc":"0,92 · 10⁻³ · U + 50 µV"},{"name":"10 Hz až 2 kHz","range":"1 V to 10 V","cmc":"0,12 · 10⁻³ · U + 0,05 mV"},{"name":"2 kHz až 10 kHz","range":"1 V to 10 V","cmc":"0,19 · 10⁻³ · U + 0,05 mV"},{"name":"10 kHz až 30 kHz","range":"1 V to 10 V","cmc":"0,38 · 10⁻³ · U + 0,1 mV"},{"name":"30 kHz až 100 kHz","range":"1 V to 10 V","cmc":"0,92 · 10⁻³ · U + 0,5 mV"},{"name":"10 Hz až 2 kHz","range":"10 V to 33 V","cmc":"0,13 · 10⁻³ · U + 0,5 mV"},{"name":"2 kHz až 10 kHz","range":"10 V to 33 V","cmc":"0,16 · 10⁻³ · U + 0,5 mV"},{"name":"10 kHz až 30 kHz","range":"10 V to 33 V","cmc":"0,38 · 10⁻³ · U + 1 mV"},{"name":"30 kHz až 100 kHz","range":"10 V to 33 V","cmc":"0,98 · 10⁻³ · U + 5 mV"},{"name":"45 Hz až 2 kHz","range":"33 V to 100 V","cmc":"0,13 · 10⁻³ · U + 0,5 mV"},{"name":"2 kHz až 10 kHz","range":"33 V to 100 V","cmc":"0,16 · 10⁻³ · U + 0,5 mV"},{"name":"10 kHz až 30 kHz","range":"33 V to 100 V","cmc":"0,38 · 10⁻³ · U + 1 mV"},{"name":"30 kHz až 100 kHz","range":"33 V to 100 V","cmc":"0,98 · 10⁻³ · U + 5 mV"},{"name":"45 Hz až 2 kHz","range":"100 V to 330 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"2 kHz až 10 kHz","range":"100 V to 330 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"10 kHz až 30 kHz","range":"100 V to 330 V","cmc":"0,38 · 10⁻³ · U + 25 mV"},{"name":"30 kHz až 100 kHz","range":"100 V to 330 V","cmc":"0,98 · 10⁻³ · U + 0,1 V"},{"name":"45 Hz až 2 kHz","range":"330 V to 1000 V","cmc":"0,16 · 10⁻³ · U + 25 mV"},{"name":"2 kHz až 10 kHz","range":"330 V to 1000 V","cmc":"0,16 · 10⁻³ · U + 25 mV"}],"reference_cs":"PW-01-1, PW-01-2, PW-01-4 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Napětí AC","search_cs":"Kalibrátory Měřicí karty Digitální měřiče napětí Multimetry Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Napětí AC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) 10 Hz až 2 kHz 2 kHz až 10 kHz 10 kHz až 30 kHz 30 kHz až 100 kHz 10 Hz až 2 kHz 2 kHz až 10 kHz 10 kHz až 30 kHz 30 kHz až 100 kHz 10 Hz až 2 kHz 2 kHz až 10 kHz 10 kHz až 30 kHz 30 kHz až 100 kHz 10 Hz až 2 kHz 2 kHz až 10 kHz 10 kHz až 30 kHz 30 kHz až 100 kHz 10 Hz až 2 kHz 2 kHz až 10 kHz 10 kHz až 30 kHz 30 kHz až 100 kHz 45 Hz až 2 kHz 2 kHz až 10 kHz 10 kHz až 30 kHz 30 kHz až 100 kHz 45 Hz až 2 kHz 2 kHz až 10 kHz 10 kHz až 30 kHz 30 kHz až 100 kHz 45 Hz až 2 kHz 2 kHz až 10 kHz PW-01-1, PW-01-2, PW-01-4 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nMěřicí karty\nDigitální měřiče napětí\nMultimetry"},{"_id":"8e0c1781e24eebfa41c31b12","lab_id":"6af7989a0ecd48de0c7068ac","country":"PL","accr_number":"AP 226","accr_body":"PCA","test_object":"Kalibratory\nKarty pomiarowe\nMierniki prądu cyfrowe\nMultimetry","test_object_en":"Calibrators\nData acquisition cards\nDigital ammeters\nMultimeters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"10 Hz do 2 kHz","range":"30 µA do 100 µA","cmc":"0,39 · 10⁻³ · I + 5 nA"},{"name":"2 kHz do 10 kHz","range":"30 µA do 100 µA","cmc":"0,75 · 10⁻³ · I + 5 nA"},{"name":"10 Hz do 2 kHz","range":"0,1 mA do 1 mA","cmc":"0,39 · 10⁻³ · I + 50 nA"},{"name":"2 kHz do 10 kHz","range":"0,1 mA do 1 mA","cmc":"0,75 · 10⁻³ · I + 50 nA"},{"name":"10 Hz do 2 kHz","range":"1 mA do 10 mA","cmc":"0,39 · 10⁻³ · I + 0,5 µA"},{"name":"2 kHz do 10 kHz","range":"1 mA do 10 mA","cmc":"0,75 · 10⁻³ · I + 0,5 µA"},{"name":"10 Hz do 2 kHz","range":"10 mA do 100 mA","cmc":"0,38 · 10⁻³ · I + 5 µA"},{"name":"2 kHz do 10 kHz","range":"10 mA do 100 mA","cmc":"0,74 · 10⁻³ · I + 5 µA"},{"name":"10 Hz do 2 kHz","range":"0,1 A do 1 A","cmc":"0,4 · 10⁻³ · I + 0,1 mA"},{"name":"2 kHz do 10 kHz","range":"0,1 A do 1 A","cmc":"0,77 · 10⁻³ · I + 0,1 mA"},{"name":"10 Hz do 2 kHz","range":"1 A do 3 A","cmc":"1,55 · 10⁻³ · I + 0,5 mA"},{"name":"2 kHz do 10 kHz","range":"1 A do 3 A","cmc":"1,41 · 10⁻³ · I + 0,5 mA"},{"name":"45 Hz do 2 kHz","range":"3 A do 10 A","cmc":"1,55 · 10⁻³ · I + 0,5 mA"},{"name":"2 kHz do 5 kHz","range":"3 A do 10 A","cmc":"1,41 · 10⁻³ · I + 0,5 mA"},{"name":"45 Hz do 2 kHz","range":"10 A do 20 A","cmc":"1,26 · 10⁻³ · I + 12 mA"},{"name":"2 kHz do 5 kHz","range":"10 A do 20 A","cmc":"1,5 · 10⁻³ · I + 12 mA"}],"parameters_en":[{"name":"10 Hz to 2 kHz","range":"30 µA to 100 µA","cmc":"0,39 · 10⁻³ · I + 5 nA"},{"name":"2 kHz to 10 kHz","range":"30 µA to 100 µA","cmc":"0,75 · 10⁻³ · I + 5 nA"},{"name":"10 Hz to 2 kHz","range":"0,1 mA to 1 mA","cmc":"0,39 · 10⁻³ · I + 50 nA"},{"name":"2 kHz to 10 kHz","range":"0,1 mA to 1 mA","cmc":"0,75 · 10⁻³ · I + 50 nA"},{"name":"10 Hz to 2 kHz","range":"1 mA to 10 mA","cmc":"0,39 · 10⁻³ · I + 0,5 µA"},{"name":"2 kHz to 10 kHz","range":"1 mA to 10 mA","cmc":"0,75 · 10⁻³ · I + 0,5 µA"},{"name":"10 Hz to 2 kHz","range":"10 mA to 100 mA","cmc":"0,38 · 10⁻³ · I + 5 µA"},{"name":"2 kHz to 10 kHz","range":"10 mA to 100 mA","cmc":"0,74 · 10⁻³ · I + 5 µA"},{"name":"10 Hz to 2 kHz","range":"0,1 A to 1 A","cmc":"0,4 · 10⁻³ · I + 0,1 mA"},{"name":"2 kHz to 10 kHz","range":"0,1 A to 1 A","cmc":"0,77 · 10⁻³ · I + 0,1 mA"},{"name":"10 Hz to 2 kHz","range":"1 A to 3 A","cmc":"1,55 · 10⁻³ · I + 0,5 mA"},{"name":"2 kHz to 10 kHz","range":"1 A to 3 A","cmc":"1,41 · 10⁻³ · I + 0,5 mA"},{"name":"45 Hz to 2 kHz","range":"3 A to 10 A","cmc":"1,55 · 10⁻³ · I + 0,5 mA"},{"name":"2 kHz to 5 kHz","range":"3 A to 10 A","cmc":"1,41 · 10⁻³ · I + 0,5 mA"},{"name":"45 Hz to 2 kHz","range":"10 A to 20 A","cmc":"1,26 · 10⁻³ · I + 12 mA"},{"name":"2 kHz to 5 kHz","range":"10 A to 20 A","cmc":"1,5 · 10⁻³ · I + 12 mA"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 2 kHz 30 µA do 100 µA CMC 0,39 · 10⁻³ · I + 5 nA\n2 kHz do 10 kHz 30 µA do 100 µA CMC 0,75 · 10⁻³ · I + 5 nA\n10 Hz do 2 kHz 0,1 mA do 1 mA CMC 0,39 · 10⁻³ · I + 50 nA\n2 kHz do 10 kHz 0,1 mA do 1 mA CMC 0,75 · 10⁻³ · I + 50 nA\n10 Hz do 2 kHz 1 mA do 10 mA CMC 0,39 · 10⁻³ · I + 0,5 µA\n2 kHz do 10 kHz 1 mA do 10 mA CMC 0,75 · 10⁻³ · I + 0,5 µA\n10 Hz do 2 kHz 10 mA do 100 mA CMC 0,38 · 10⁻³ · I + 5 µA\n2 kHz do 10 kHz 10 mA do 100 mA CMC 0,74 · 10⁻³ · I + 5 µA\n10 Hz do 2 kHz 0,1 A do 1 A CMC 0,4 · 10⁻³ · I + 0,1 mA\n2 kHz do 10 kHz 0,1 A do 1 A CMC 0,77 · 10⁻³ · I + 0,1 mA\n10 Hz do 2 kHz 1 A do 3 A CMC 1,55 · 10⁻³ · I + 0,5 mA\n2 kHz do 10 kHz 1 A do 3 A CMC 1,41 · 10⁻³ · I + 0,5 mA\n45 Hz do 2 kHz 3 A do 10 A CMC 1,55 · 10⁻³ · I + 0,5 mA\n2 kHz do 5 kHz 3 A do 10 A CMC 1,41 · 10⁻³ · I + 0,5 mA\n45 Hz do 2 kHz 10 A do 20 A CMC 1,26 · 10⁻³ · I + 12 mA\n2 kHz do 5 kHz 10 A do 20 A CMC 1,5 · 10⁻³ · I + 12 mA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PW-01-1, PW-01-2, PW-01-4 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PW-01-1","PW-01-2","PW-01-4","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":"I – wielkość mierzona (A)","note_en":"I – measured quantity (A)","search_text":"Kalibratory\nKarty pomiarowe\nMierniki prądu cyfrowe\nMultimetry Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 2 kHz 30 µA do 100 µA CMC 0,39 · 10⁻³ · I + 5 nA\n2 kHz do 10 kHz 30 µA do 100 µA CMC 0,75 · 10⁻³ · I + 5 nA\n10 Hz do 2 kHz 0,1 mA do 1 mA CMC 0,39 · 10⁻³ · I + 50 nA\n2 kHz do 10 kHz 0,1 mA do 1 mA CMC 0,75 · 10⁻³ · I + 50 nA\n10 Hz do 2 kHz 1 mA do 10 mA CMC 0,39 · 10⁻³ · I + 0,5 µA\n2 kHz do 10 kHz 1 mA do 10 mA CMC 0,75 · 10⁻³ · I + 0,5 µA\n10 Hz do 2 kHz 10 mA do 100 mA CMC 0,38 · 10⁻³ · I + 5 µA\n2 kHz do 10 kHz 10 mA do 100 mA CMC 0,74 · 10⁻³ · I + 5 µA\n10 Hz do 2 kHz 0,1 A do 1 A CMC 0,4 · 10⁻³ · I + 0,1 mA\n2 kHz do 10 kHz 0,1 A do 1 A CMC 0,77 · 10⁻³ · I + 0,1 mA\n10 Hz do 2 kHz 1 A do 3 A CMC 1,55 · 10⁻³ · I + 0,5 mA\n2 kHz do 10 kHz 1 A do 3 A CMC 1,41 · 10⁻³ · I + 0,5 mA\n45 Hz do 2 kHz 3 A do 10 A CMC 1,55 · 10⁻³ · I + 0,5 mA\n2 kHz do 5 kHz 3 A do 10 A CMC 1,41 · 10⁻³ · I + 0,5 mA\n45 Hz do 2 kHz 10 A do 20 A CMC 1,26 · 10⁻³ · I + 12 mA\n2 kHz do 5 kHz 10 A do 20 A CMC 1,5 · 10⁻³ · I + 12 mA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PW-01-1, PW-01-2, PW-01-4 w oparciu o EURAMET cg-15 v.3.0 Kalibratory\nKarty pomiarowe\nMierniki pradu cyfrowe\nMultimetry Wzorcowanie — Prad AC\nZakres:\n10 Hz do 2 kHz 30 µA do 100 µA CMC 0,39 · 10⁻³ · I + 5 nA\n2 kHz do 10 kHz 30 µA do 100 µA CMC 0,75 · 10⁻³ · I + 5 nA\n10 Hz do 2 kHz 0,1 mA do 1 mA CMC 0,39 · 10⁻³ · I + 50 nA\n2 kHz do 10 kHz 0,1 mA do 1 mA CMC 0,75 · 10⁻³ · I + 50 nA\n10 Hz do 2 kHz 1 mA do 10 mA CMC 0,39 · 10⁻³ · I + 0,5 µA\n2 kHz do 10 kHz 1 mA do 10 mA CMC 0,75 · 10⁻³ · I + 0,5 µA\n10 Hz do 2 kHz 10 mA do 100 mA CMC 0,38 · 10⁻³ · I + 5 µA\n2 kHz do 10 kHz 10 mA do 100 mA CMC 0,74 · 10⁻³ · I + 5 µA\n10 Hz do 2 kHz 0,1 A do 1 A CMC 0,4 · 10⁻³ · I + 0,1 mA\n2 kHz do 10 kHz 0,1 A do 1 A CMC 0,77 · 10⁻³ · I + 0,1 mA\n10 Hz do 2 kHz 1 A do 3 A CMC 1,55 · 10⁻³ · I + 0,5 mA\n2 kHz do 10 kHz 1 A do 3 A CMC 1,41 · 10⁻³ · I + 0,5 mA\n45 Hz do 2 kHz 3 A do 10 A CMC 1,55 · 10⁻³ · I + 0,5 mA\n2 kHz do 5 kHz 3 A do 10 A CMC 1,41 · 10⁻³ · I + 0,5 mA\n45 Hz do 2 kHz 10 A do 20 A CMC 1,26 · 10⁻³ · I + 12 mA\n2 kHz do 5 kHz 10 A do 20 A CMC 1,5 · 10⁻³ · I + 12 mA\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PW-01-1, PW-01-2, PW-01-4 w oparciu o EURAMET cg-15 v.3.0","search_en":"Calibrators Data acquisition cards Digital ammeters Multimeters Calibration — AC current Internal procedure; Direct method; At permanent location (S) AC current Internal procedure Direct method At permanent location (S) 10 Hz to 2 kHz 2 kHz to 10 kHz 10 Hz to 2 kHz 2 kHz to 10 kHz 10 Hz to 2 kHz 2 kHz to 10 kHz 10 Hz to 2 kHz 2 kHz to 10 kHz 10 Hz to 2 kHz 2 kHz to 10 kHz 10 Hz to 2 kHz 2 kHz to 10 kHz 45 Hz to 2 kHz 2 kHz to 5 kHz 45 Hz to 2 kHz 2 kHz to 5 kHz PW-01-1, PW-01-2, PW-01-4 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-01-1, PW-01-2, PW-01-4 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"10 Hz bis 2 kHz","range":"30 µA to 100 µA","cmc":"0,39 · 10⁻³ · I + 5 nA"},{"name":"2 kHz bis 10 kHz","range":"30 µA to 100 µA","cmc":"0,75 · 10⁻³ · I + 5 nA"},{"name":"10 Hz bis 2 kHz","range":"0,1 mA to 1 mA","cmc":"0,39 · 10⁻³ · I + 50 nA"},{"name":"2 kHz bis 10 kHz","range":"0,1 mA to 1 mA","cmc":"0,75 · 10⁻³ · I + 50 nA"},{"name":"10 Hz bis 2 kHz","range":"1 mA to 10 mA","cmc":"0,39 · 10⁻³ · I + 0,5 µA"},{"name":"2 kHz bis 10 kHz","range":"1 mA to 10 mA","cmc":"0,75 · 10⁻³ · I + 0,5 µA"},{"name":"10 Hz bis 2 kHz","range":"10 mA bis 100 mA","cmc":"0,38 · 10⁻³ · I + 5 µA"},{"name":"2 kHz bis 10 kHz","range":"10 mA bis 100 mA","cmc":"0,74 · 10⁻³ · I + 5 µA"},{"name":"10 Hz bis 2 kHz","range":"0,1 A to 1 A","cmc":"0,4 · 10⁻³ · I + 0,1 mA"},{"name":"2 kHz bis 10 kHz","range":"0,1 A to 1 A","cmc":"0,77 · 10⁻³ · I + 0,1 mA"},{"name":"10 Hz bis 2 kHz","range":"1 A to 3 A","cmc":"1,55 · 10⁻³ · I + 0,5 mA"},{"name":"2 kHz bis 10 kHz","range":"1 A to 3 A","cmc":"1,41 · 10⁻³ · I + 0,5 mA"},{"name":"45 Hz bis 2 kHz","range":"3 A to 10 A","cmc":"1,55 · 10⁻³ · I + 0,5 mA"},{"name":"2 kHz bis 5 kHz","range":"3 A to 10 A","cmc":"1,41 · 10⁻³ · I + 0,5 mA"},{"name":"45 Hz bis 2 kHz","range":"10 A to 20 A","cmc":"1,26 · 10⁻³ · I + 12 mA"},{"name":"2 kHz bis 5 kHz","range":"10 A to 20 A","cmc":"1,5 · 10⁻³ · I + 12 mA"}],"reference_de":"PW-01-1, PW-01-2, PW-01-4 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"AC-Strom","search_de":"Kalibratoren Messkarten Digitale Strommessgeräte Multimeter Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) 10 Hz bis 2 kHz 2 kHz bis 10 kHz 10 Hz bis 2 kHz 2 kHz bis 10 kHz 10 Hz bis 2 kHz 2 kHz bis 10 kHz 10 Hz bis 2 kHz 2 kHz bis 10 kHz 10 Hz bis 2 kHz 2 kHz bis 10 kHz 10 Hz bis 2 kHz 2 kHz bis 10 kHz 45 Hz bis 2 kHz 2 kHz bis 5 kHz 45 Hz bis 2 kHz 2 kHz bis 5 kHz PW-01-1, PW-01-2, PW-01-4 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nMesskarten\nDigitale Strommessgeräte\nMultimeter","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"10 Hz 至 2 kHz","range":"30 µA to 100 µA","cmc":"0,39 · 10⁻³ · I + 5 nA"},{"name":"2 kHz 至 10 kHz","range":"30 µA to 100 µA","cmc":"0,75 · 10⁻³ · I + 5 nA"},{"name":"10 Hz 至 2 kHz","range":"0,1 mA to 1 mA","cmc":"0,39 · 10⁻³ · I + 50 nA"},{"name":"2 kHz 至 10 kHz","range":"0,1 mA to 1 mA","cmc":"0,75 · 10⁻³ · I + 50 nA"},{"name":"10 Hz 至 2 kHz","range":"1 mA to 10 mA","cmc":"0,39 · 10⁻³ · I + 0,5 µA"},{"name":"2 kHz 至 10 kHz","range":"1 mA to 10 mA","cmc":"0,75 · 10⁻³ · I + 0,5 µA"},{"name":"10 Hz 至 2 kHz","range":"10 mA to 100 mA","cmc":"0,38 · 10⁻³ · I + 5 µA"},{"name":"2 kHz 至 10 kHz","range":"10 mA to 100 mA","cmc":"0,74 · 10⁻³ · I + 5 µA"},{"name":"10 Hz 至 2 kHz","range":"0,1 A to 1 A","cmc":"0,4 · 10⁻³ · I + 0,1 mA"},{"name":"2 kHz 至 10 kHz","range":"0,1 A to 1 A","cmc":"0,77 · 10⁻³ · I + 0,1 mA"},{"name":"10 Hz 至 2 kHz","range":"1 A to 3 A","cmc":"1,55 · 10⁻³ · I + 0,5 mA"},{"name":"2 kHz 至 10 kHz","range":"1 A to 3 A","cmc":"1,41 · 10⁻³ · I + 0,5 mA"},{"name":"45 Hz 至 2 kHz","range":"3 A to 10 A","cmc":"1,55 · 10⁻³ · I + 0,5 mA"},{"name":"2 kHz 至 5 kHz","range":"3 A to 10 A","cmc":"1,41 · 10⁻³ · I + 0,5 mA"},{"name":"45 Hz 至 2 kHz","range":"10 A to 20 A","cmc":"1,26 · 10⁻³ · I + 12 mA"},{"name":"2 kHz 至 5 kHz","range":"10 A to 20 A","cmc":"1,5 · 10⁻³ · I + 12 mA"}],"reference_zh":"PW-01-1, PW-01-2, PW-01-4 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"交流电流","search_zh":"校准器 测量卡 数字电流表 万用表 校准 — 交流电流 内部程序；直接法；在固定地点 (S) 交流电流 内部程序 直接法 在固定地点 (S) 10 Hz 至 2 kHz 2 kHz 至 10 kHz 10 Hz 至 2 kHz 2 kHz 至 10 kHz 10 Hz 至 2 kHz 2 kHz 至 10 kHz 10 Hz 至 2 kHz 2 kHz 至 10 kHz 10 Hz 至 2 kHz 2 kHz 至 10 kHz 10 Hz 至 2 kHz 2 kHz 至 10 kHz 45 Hz 至 2 kHz 2 kHz 至 5 kHz 45 Hz 至 2 kHz 2 kHz 至 5 kHz PW-01-1, PW-01-2, PW-01-4 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"校准器\n测量卡\n数字电流表\n万用表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"10 Hz až 2 kHz","range":"30 µA to 100 µA","cmc":"0,39 · 10⁻³ · I + 5 nA"},{"name":"2 kHz až 10 kHz","range":"30 µA to 100 µA","cmc":"0,75 · 10⁻³ · I + 5 nA"},{"name":"10 Hz až 2 kHz","range":"0,1 mA to 1 mA","cmc":"0,39 · 10⁻³ · I + 50 nA"},{"name":"2 kHz až 10 kHz","range":"0,1 mA to 1 mA","cmc":"0,75 · 10⁻³ · I + 50 nA"},{"name":"10 Hz až 2 kHz","range":"1 mA to 10 mA","cmc":"0,39 · 10⁻³ · I + 0,5 µA"},{"name":"2 kHz až 10 kHz","range":"1 mA to 10 mA","cmc":"0,75 · 10⁻³ · I + 0,5 µA"},{"name":"10 Hz až 2 kHz","range":"10 mA to 100 mA","cmc":"0,38 · 10⁻³ · I + 5 µA"},{"name":"2 kHz až 10 kHz","range":"10 mA to 100 mA","cmc":"0,74 · 10⁻³ · I + 5 µA"},{"name":"10 Hz až 2 kHz","range":"0,1 A to 1 A","cmc":"0,4 · 10⁻³ · I + 0,1 mA"},{"name":"2 kHz až 10 kHz","range":"0,1 A to 1 A","cmc":"0,77 · 10⁻³ · I + 0,1 mA"},{"name":"10 Hz až 2 kHz","range":"1 A to 3 A","cmc":"1,55 · 10⁻³ · I + 0,5 mA"},{"name":"2 kHz až 10 kHz","range":"1 A to 3 A","cmc":"1,41 · 10⁻³ · I + 0,5 mA"},{"name":"45 Hz až 2 kHz","range":"3 A to 10 A","cmc":"1,55 · 10⁻³ · I + 0,5 mA"},{"name":"2 kHz až 5 kHz","range":"3 A to 10 A","cmc":"1,41 · 10⁻³ · I + 0,5 mA"},{"name":"45 Hz až 2 kHz","range":"10 A to 20 A","cmc":"1,26 · 10⁻³ · I + 12 mA"},{"name":"2 kHz až 5 kHz","range":"10 A to 20 A","cmc":"1,5 · 10⁻³ · I + 12 mA"}],"reference_cs":"PW-01-1, PW-01-2, PW-01-4 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Proud AC","search_cs":"Kalibrátory Měřicí karty Digitální měřiče proudu Multimetry Kalibrace — Proud AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Proud AC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) 10 Hz až 2 kHz 2 kHz až 10 kHz 10 Hz až 2 kHz 2 kHz až 10 kHz 10 Hz až 2 kHz 2 kHz až 10 kHz 10 Hz až 2 kHz 2 kHz až 10 kHz 10 Hz až 2 kHz 2 kHz až 10 kHz 10 Hz až 2 kHz 2 kHz až 10 kHz 45 Hz až 2 kHz 2 kHz až 5 kHz 45 Hz až 2 kHz 2 kHz až 5 kHz PW-01-1, PW-01-2, PW-01-4 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nMěřicí karty\nDigitální měřiče proudu\nMultimetry"},{"_id":"1090535c10d3167cad92b666","lab_id":"6af7989a0ecd48de0c7068ac","country":"PL","accr_number":"AP 226","accr_body":"PCA","test_object":"Kalibratory rezystancji\nKarty pomiarowe\nMierniki rezystancji cyfrowe\nMultimetry","test_object_en":"Resistance calibrators\nData acquisition cards\nDigital ohmmeters\nMultimeters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0 Ω do 100 Ω","cmc":"14 · 10⁻⁶ · R + 50 µΩ"},{"name":"","range":"0,1 kΩ do 1 kΩ","cmc":"14 · 10⁻⁶ · R + 0,5 mΩ"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"14 · 10⁻⁶ · R + 5 mΩ"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"14 · 10⁻⁶ · R + 50 mΩ"},{"name":"","range":"0,1 MΩ do 1 MΩ","cmc":"16 · 10⁻⁶ · R + 1 Ω"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"28 · 10⁻⁶ · R + 0,1 kΩ"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"0,18 · 10⁻³ · R + 10 kΩ"}],"parameters_en":[{"name":"","range":"0 Ω to 100 Ω","cmc":"14 · 10⁻⁶ · R + 50 µΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"14 · 10⁻⁶ · R + 0,5 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"14 · 10⁻⁶ · R + 5 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"14 · 10⁻⁶ · R + 50 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"16 · 10⁻⁶ · R + 1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"28 · 10⁻⁶ · R + 0,1 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,18 · 10⁻³ · R + 10 kΩ"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0 Ω do 100 Ω CMC 14 · 10⁻⁶ · R + 50 µΩ\n0,1 kΩ do 1 kΩ CMC 14 · 10⁻⁶ · R + 0,5 mΩ\n1 kΩ do 10 kΩ CMC 14 · 10⁻⁶ · R + 5 mΩ\n10 kΩ do 100 kΩ CMC 14 · 10⁻⁶ · R + 50 mΩ\n0,1 MΩ do 1 MΩ CMC 16 · 10⁻⁶ · R + 1 Ω\n1 MΩ do 10 MΩ CMC 28 · 10⁻⁶ · R + 0,1 kΩ\n10 MΩ do 100 MΩ CMC 0,18 · 10⁻³ · R + 10 kΩ\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PW-01-1, PW-01-2, PW-01-4 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PW-01-1","PW-01-2","PW-01-4","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":"R – wielkość mierzona (Ω)","note_en":"R – measured quantity (Ω)","search_text":"Kalibratory rezystancji\nKarty pomiarowe\nMierniki rezystancji cyfrowe\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n0 Ω do 100 Ω CMC 14 · 10⁻⁶ · R + 50 µΩ\n0,1 kΩ do 1 kΩ CMC 14 · 10⁻⁶ · R + 0,5 mΩ\n1 kΩ do 10 kΩ CMC 14 · 10⁻⁶ · R + 5 mΩ\n10 kΩ do 100 kΩ CMC 14 · 10⁻⁶ · R + 50 mΩ\n0,1 MΩ do 1 MΩ CMC 16 · 10⁻⁶ · R + 1 Ω\n1 MΩ do 10 MΩ CMC 28 · 10⁻⁶ · R + 0,1 kΩ\n10 MΩ do 100 MΩ CMC 0,18 · 10⁻³ · R + 10 kΩ\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PW-01-1, PW-01-2, PW-01-4 w oparciu o EURAMET cg-15 v.3.0 Kalibratory rezystancji\nKarty pomiarowe\nMierniki rezystancji cyfrowe\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n0 Ω do 100 Ω CMC 14 · 10⁻⁶ · R + 50 µΩ\n0,1 kΩ do 1 kΩ CMC 14 · 10⁻⁶ · R + 0,5 mΩ\n1 kΩ do 10 kΩ CMC 14 · 10⁻⁶ · R + 5 mΩ\n10 kΩ do 100 kΩ CMC 14 · 10⁻⁶ · R + 50 mΩ\n0,1 MΩ do 1 MΩ CMC 16 · 10⁻⁶ · R + 1 Ω\n1 MΩ do 10 MΩ CMC 28 · 10⁻⁶ · R + 0,1 kΩ\n10 MΩ do 100 MΩ CMC 0,18 · 10⁻³ · R + 10 kΩ\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PW-01-1, PW-01-2, PW-01-4 w oparciu o EURAMET cg-15 v.3.0","search_en":"Resistance calibrators Data acquisition cards Digital ohmmeters Multimeters Calibration — DC resistance Internal procedure; Direct method; At permanent location (S) DC resistance Internal procedure Direct method At permanent location (S) PW-01-1, PW-01-2, PW-01-4 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-01-1, PW-01-2, PW-01-4 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0 Ω to 100 Ω","cmc":"14 · 10⁻⁶ · R + 50 µΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"14 · 10⁻⁶ · R + 0,5 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"14 · 10⁻⁶ · R + 5 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"14 · 10⁻⁶ · R + 50 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"16 · 10⁻⁶ · R + 1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"28 · 10⁻⁶ · R + 0,1 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,18 · 10⁻³ · R + 10 kΩ"}],"reference_de":"PW-01-1, PW-01-2, PW-01-4 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"DC-Widerstand","search_de":"Widerstandskalibratoren Messkarten Digitale Widerstandsmessgeräte Multimeter Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Direktes Verfahren Am festen Standort (S) PW-01-1, PW-01-2, PW-01-4 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Widerstandskalibratoren\nMesskarten\nDigitale Widerstandsmessgeräte\nMultimeter","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0 Ω to 100 Ω","cmc":"14 · 10⁻⁶ · R + 50 µΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"14 · 10⁻⁶ · R + 0,5 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"14 · 10⁻⁶ · R + 5 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"14 · 10⁻⁶ · R + 50 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"16 · 10⁻⁶ · R + 1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"28 · 10⁻⁶ · R + 0,1 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,18 · 10⁻³ · R + 10 kΩ"}],"reference_zh":"PW-01-1, PW-01-2, PW-01-4 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"直流电阻","search_zh":"电阻校准器 测量卡 数字电阻测量仪 万用表 校准 — 直流电阻 内部程序；直接法；在固定地点 (S) 直流电阻 内部程序 直接法 在固定地点 (S) PW-01-1, PW-01-2, PW-01-4 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"电阻校准器\n测量卡\n数字电阻测量仪\n万用表","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0 Ω to 100 Ω","cmc":"14 · 10⁻⁶ · R + 50 µΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"14 · 10⁻⁶ · R + 0,5 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"14 · 10⁻⁶ · R + 5 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"14 · 10⁻⁶ · R + 50 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"16 · 10⁻⁶ · R + 1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"28 · 10⁻⁶ · R + 0,1 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,18 · 10⁻³ · R + 10 kΩ"}],"reference_cs":"PW-01-1, PW-01-2, PW-01-4 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Odpor DC","search_cs":"Kalibrátory odporu Měřicí karty Digitální měřiče odporu Multimetry Kalibrace — Odpor DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) PW-01-1, PW-01-2, PW-01-4 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory odporu\nMěřicí karty\nDigitální měřiče odporu\nMultimetry"}],"has_pdf":true}