{"lab":{"_id":"6af323270ecd48de0c705b88","country":"PL","accr_number":"AP 224","imported_at":"2026-11-10T12:00:00.000Z","accr_body":"PCA","activity_conducted":"poza stałą lokalizacją (P)","activity_conducted_en":"outside of permanent location (P)","address":"ul. Książęca 16, 62-020 Gortatowo","approver":"Tadeusz Matras","categories":["metrology"],"certificate_date":"11.02.2025","city":"Gortatowo","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. The CMC uncertainty expressed as a percentage is the relative measurement uncertainty and refers to the percentage share in the value of the measurand.","cycle_from":"11.02.2025","cycle_to":"10.02.2029","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"6.01","pl":"długość","en":"length","de":"Länge","zh":"长度","cs":"délka"},{"codes":"12.02","pl":"moment siły","en":"torque","de":"Drehmoment","zh":"力矩","cs":"moment síly"},{"codes":"17.01","pl":"ciśnienie","en":"pressure","de":"Druck","zh":"压力","cs":"tlak"}],"has_en":true,"has_zh":true,"issue":{"no":"2","date":"11.02.2026"},"issue_date":"11.02.2026","issue_number":"2","lab_division":"Laboratorium Wzorcujące Mobi-Lab","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[17.095561,52.427091]},"map_coord":[52.427091,17.095561],"map_geo":"nominatim-street","methods_count":5,"name":"Mobi-Lab Patryk Jaskuła","parse_date":"2026-11-10T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-10T12:00:00.000Z","pdf_files":["AP_224.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: długość, moment siły, ciśnienie. Poza stałą lokalizacją (P).","search_text":"mobi-lab patryk jaskuła laboratorium wzorcujące mobi-lab ul. książęca 16, 62-020 gortatowo laboratorium wzorcujące. wielkości mierzone: długość, moment siły, ciśnienie. poza stałą lokalizacją (p). ap 224 ap224 laboratorium wzorcujące wzorcowanie kalibracja length torque pressure mobi-lab patryk jaskula laboratorium wzorcujace mobi-lab ul. ksiazeca 16, 62-020 gortatowo laboratorium wzorcujace. wielkosci mierzone: dlugosc, moment sily, cisnienie. poza stala lokalizacja (p). ap 224 ap224 laboratorium wzorcujace wzorcowanie kalibracja length torque pressure","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20224,podmiot.html","source_pdf_sha256":"1b46df6d22d8d167016e6f6cec6778e6ee0be5c76e999d6128ff27d76d74213c","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/10/41ff8a76a9d70bd4e7e4315407e78fed/AP%20224.pdf","status":"active","updated_at":"2026-11-10T12:00:00.000Z","valid_from":"11-02-2025","valid_until":"10-02-2029","website":"www.mobi-lab.pl","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"lab_division_de":"Kalibrierlaboratorium Mobi-Lab","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","lab_division_zh":"Mobi-Lab 校准实验室","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"lab_division_cs":"Kalibrační laboratoř Mobi-Lab","pelny_cs":true},"methods":[{"_id":"725432e743cb786a6572dddc","lab_id":"6af323270ecd48de0c705b88","country":"PL","accr_number":"AP 224","accr_body":"PCA","test_object":"Suwmiarki","test_object_en":"Calipers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 150 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"17 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 150 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"17 µm"}],"technique":"Poza stałą lokalizacją (P)","technique_en":"Outside of permanent location (P)","techniques":["Poza stałą lokalizacją (P)"],"techniques_en":["Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 14 µm\n0 mm do 150 mm CMC 15 µm\n0 mm do 300 mm CMC 17 µm\nPoza stałą lokalizacją (P)","reference":"PN-EN ISO/IEC 13385:2019","norm_bases":["PN-EN ISO/IEC 13385:2019"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Suwmiarki Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 14 µm\n0 mm do 150 mm CMC 15 µm\n0 mm do 300 mm CMC 17 µm\nPoza stałą lokalizacją (P) PN-EN ISO/IEC 13385:2019 Suwmiarki Wzorcowanie — Dlugosc\nZakres:\n0 mm do 50 mm CMC 14 µm\n0 mm do 150 mm CMC 15 µm\n0 mm do 300 mm CMC 17 µm\nPoza stala lokalizacja (P) PN-EN ISO/IEC 13385:2019","search_en":"Calipers Calibration — Length Outside of permanent location (P) Length Outside of permanent location (P) PN-EN ISO/IEC 13385:2019","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 150 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"17 µm"}],"regulatory_area_de":"Länge","search_de":"Messschieber Kalibrierung — Länge Außerhalb des festen Standorts (P) Länge Außerhalb des festen Standorts (P) PN-EN ISO/IEC 13385:2019","technique_de":"Außerhalb des festen Standorts (P)","techniques_de":["Außerhalb des festen Standorts (P)"],"test_object_de":"Messschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 150 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"17 µm"}],"regulatory_area_zh":"长度","search_zh":"游标卡尺 校准 — 长度 固定地点以外 (P) 长度 固定地点以外 (P) PN-EN ISO/IEC 13385:2019","technique_zh":"固定地点以外 (P)","techniques_zh":["固定地点以外 (P)"],"test_object_zh":"游标卡尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 150 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"17 µm"}],"regulatory_area_cs":"Délka","search_cs":"Posuvná měřidla Kalibrace — Délka Mimo stálou lokalitu (P) Délka Mimo stálou lokalitu (P) PN-EN ISO/IEC 13385:2019","technique_cs":"Mimo stálou lokalitu (P)","techniques_cs":["Mimo stálou lokalitu (P)"],"test_object_cs":"Posuvná měřidla"},{"_id":"03aaf2978ad2ca8efe224eab","lab_id":"6af323270ecd48de0c705b88","country":"PL","accr_number":"AP 224","accr_body":"PCA","test_object":"Mikrometry zewnętrzne","test_object_en":"External micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 25 mm","cmc":"1,8 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"2,2 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"3,0 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"3,6 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"4,8 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"5,5 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"6,4 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"7,2 µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"1,8 µm"},{"name":"","range":"25 mm to 50 mm","cmc":"2,2 µm"},{"name":"","range":"50 mm to 75 mm","cmc":"3,0 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"3,6 µm"},{"name":"","range":"100 mm to 125 mm","cmc":"4,8 µm"},{"name":"","range":"125 mm to 150 mm","cmc":"5,5 µm"},{"name":"","range":"150 mm to 175 mm","cmc":"6,4 µm"},{"name":"","range":"175 mm to 200 mm","cmc":"7,2 µm"}],"technique":"Poza stałą lokalizacją (P)","technique_en":"Outside of permanent location (P)","techniques":["Poza stałą lokalizacją (P)"],"techniques_en":["Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 1,8 µm\n25 mm do 50 mm CMC 2,2 µm\n50 mm do 75 mm CMC 3,0 µm\n75 mm do 100 mm CMC 3,6 µm\n100 mm do 125 mm CMC 4,8 µm\n125 mm do 150 mm CMC 5,5 µm\n150 mm do 175 mm CMC 6,4 µm\n175 mm do 200 mm CMC 7,2 µm\nPoza stałą lokalizacją (P)","reference":"PN EN-ISO 3611:2023-10E","norm_bases":["PN EN-ISO 3611:2023-10E"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Mikrometry zewnętrzne Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 1,8 µm\n25 mm do 50 mm CMC 2,2 µm\n50 mm do 75 mm CMC 3,0 µm\n75 mm do 100 mm CMC 3,6 µm\n100 mm do 125 mm CMC 4,8 µm\n125 mm do 150 mm CMC 5,5 µm\n150 mm do 175 mm CMC 6,4 µm\n175 mm do 200 mm CMC 7,2 µm\nPoza stałą lokalizacją (P) PN EN-ISO 3611:2023-10E Mikrometry zewnetrzne Wzorcowanie — Dlugosc\nZakres:\n0 mm do 25 mm CMC 1,8 µm\n25 mm do 50 mm CMC 2,2 µm\n50 mm do 75 mm CMC 3,0 µm\n75 mm do 100 mm CMC 3,6 µm\n100 mm do 125 mm CMC 4,8 µm\n125 mm do 150 mm CMC 5,5 µm\n150 mm do 175 mm CMC 6,4 µm\n175 mm do 200 mm CMC 7,2 µm\nPoza stala lokalizacja (P) PN EN-ISO 3611:2023-10E","search_en":"External micrometers Calibration — Length Outside of permanent location (P) Length Outside of permanent location (P) PN EN-ISO 3611:2023-10E","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 25 mm","cmc":"1,8 µm"},{"name":"","range":"25 mm bis 50 mm","cmc":"2,2 µm"},{"name":"","range":"50 mm bis 75 mm","cmc":"3,0 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"3,6 µm"},{"name":"","range":"100 mm bis 125 mm","cmc":"4,8 µm"},{"name":"","range":"125 mm bis 150 mm","cmc":"5,5 µm"},{"name":"","range":"150 mm bis 175 mm","cmc":"6,4 µm"},{"name":"","range":"175 mm bis 200 mm","cmc":"7,2 µm"}],"regulatory_area_de":"Länge","search_de":"Bügelmessschrauben Kalibrierung — Länge Außerhalb des festen Standorts (P) Länge Außerhalb des festen Standorts (P) PN EN-ISO 3611:2023-10E","technique_de":"Außerhalb des festen Standorts (P)","techniques_de":["Außerhalb des festen Standorts (P)"],"test_object_de":"Bügelmessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"1,8 µm"},{"name":"","range":"25 mm 至 50 mm","cmc":"2,2 µm"},{"name":"","range":"50 mm 至 75 mm","cmc":"3,0 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"3,6 µm"},{"name":"","range":"100 mm 至 125 mm","cmc":"4,8 µm"},{"name":"","range":"125 mm 至 150 mm","cmc":"5,5 µm"},{"name":"","range":"150 mm 至 175 mm","cmc":"6,4 µm"},{"name":"","range":"175 mm 至 200 mm","cmc":"7,2 µm"}],"regulatory_area_zh":"长度","search_zh":"外径千分尺 校准 — 长度 固定地点以外 (P) 长度 固定地点以外 (P) PN EN-ISO 3611:2023-10E","technique_zh":"固定地点以外 (P)","techniques_zh":["固定地点以外 (P)"],"test_object_zh":"外径千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 25 mm","cmc":"1,8 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"2,2 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"3,0 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"3,6 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"4,8 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"5,5 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"6,4 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"7,2 µm"}],"regulatory_area_cs":"Délka","search_cs":"Mikrometry pro vnější měření Kalibrace — Délka Mimo stálou lokalitu (P) Délka Mimo stálou lokalitu (P) PN EN-ISO 3611:2023-10E","technique_cs":"Mimo stálou lokalitu (P)","techniques_cs":["Mimo stálou lokalitu (P)"],"test_object_cs":"Mikrometry pro vnější měření"},{"_id":"89c7d5f3f23a015fff450b6e","lab_id":"6af323270ecd48de0c705b88","country":"PL","accr_number":"AP 224","accr_body":"PCA","test_object":"Klucze dynamometryczne","test_object_en":"Torque wrenches","methodology":"Wzorcowanie — Moment siły","methodology_en":"Calibration — Torque","parameters":[{"name":"","range":"0,2 Nm do 1000 Nm","cmc":"0,54 %"}],"parameters_en":[{"name":"","range":"0,2 Nm to 1000 Nm","cmc":"0,54 %"}],"technique":"Poza stałą lokalizacją (P)","technique_en":"Outside of permanent location (P)","techniques":["Poza stałą lokalizacją (P)"],"techniques_en":["Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moment siły\n0,2 Nm do 1000 Nm CMC 0,54 %\nPoza stałą lokalizacją (P)","reference":"PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03","norm_bases":["PN-EN ISO/IEC 6789-1:2017-03","PN-EN ISO/IEC 6789-2:2017-03"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moment siły","regulatory_area_en":"Torque","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Klucze dynamometryczne Wzorcowanie — Moment siły\n0,2 Nm do 1000 Nm CMC 0,54 %\nPoza stałą lokalizacją (P) PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03 Klucze dynamometryczne Wzorcowanie — Moment sily\n0,2 Nm do 1000 Nm CMC 0,54 %\nPoza stala lokalizacja (P) PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03","search_en":"Torque wrenches Calibration — Torque Outside of permanent location (P) Torque Outside of permanent location (P) PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Drehmoment","parameters_de":[{"name":"","range":"0,2 Nm to 1000 Nm","cmc":"0,54 %"}],"regulatory_area_de":"Drehmoment","search_de":"Drehmomentschlüssel Kalibrierung — Drehmoment Außerhalb des festen Standorts (P) Drehmoment Außerhalb des festen Standorts (P) PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03","technique_de":"Außerhalb des festen Standorts (P)","techniques_de":["Außerhalb des festen Standorts (P)"],"test_object_de":"Drehmomentschlüssel","methodology_zh":"校准 — 力矩","parameters_zh":[{"name":"","range":"0,2 Nm to 1000 Nm","cmc":"0,54 %"}],"regulatory_area_zh":"力矩","search_zh":"扭矩扳手 校准 — 力矩 固定地点以外 (P) 力矩 固定地点以外 (P) PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03","technique_zh":"固定地点以外 (P)","techniques_zh":["固定地点以外 (P)"],"test_object_zh":"扭矩扳手","methodology_cs":"Kalibrace — Moment síly","parameters_cs":[{"name":"","range":"0,2 Nm to 1000 Nm","cmc":"0,54 %"}],"regulatory_area_cs":"Moment síly","search_cs":"Momentové klíče Kalibrace — Moment síly Mimo stálou lokalitu (P) Moment síly Mimo stálou lokalitu (P) PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03","technique_cs":"Mimo stálou lokalitu (P)","techniques_cs":["Mimo stálou lokalitu (P)"],"test_object_cs":"Momentové klíče"},{"_id":"1a841acfc085887d18d9ca4b","lab_id":"6af323270ecd48de0c705b88","country":"PL","accr_number":"AP 224","accr_body":"PCA","test_object":"Wkrętaki dynamometryczne","test_object_en":"Torque screwdrivers","methodology":"Wzorcowanie — Moment siły","methodology_en":"Calibration — Torque","parameters":[{"name":"","range":"0,2 Nm do 10 Nm","cmc":"1,20 %"}],"parameters_en":[{"name":"","range":"0,2 Nm to 10 Nm","cmc":"1,20 %"}],"technique":"Poza stałą lokalizacją (P)","technique_en":"Outside of permanent location (P)","techniques":["Poza stałą lokalizacją (P)"],"techniques_en":["Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moment siły\n0,2 Nm do 10 Nm CMC 1,20 %\nPoza stałą lokalizacją (P)","reference":"PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03","norm_bases":["PN-EN ISO/IEC 6789-1:2017-03","PN-EN ISO/IEC 6789-2:2017-03"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moment siły","regulatory_area_en":"Torque","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Wkrętaki dynamometryczne Wzorcowanie — Moment siły\n0,2 Nm do 10 Nm CMC 1,20 %\nPoza stałą lokalizacją (P) PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03 Wkretaki dynamometryczne Wzorcowanie — Moment sily\n0,2 Nm do 10 Nm CMC 1,20 %\nPoza stala lokalizacja (P) PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03","search_en":"Torque screwdrivers Calibration — Torque Outside of permanent location (P) Torque Outside of permanent location (P) PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Drehmoment","parameters_de":[{"name":"","range":"0,2 Nm to 10 Nm","cmc":"1,20 %"}],"regulatory_area_de":"Drehmoment","search_de":"Drehmomentschraubendreher Kalibrierung — Drehmoment Außerhalb des festen Standorts (P) Drehmoment Außerhalb des festen Standorts (P) PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03","technique_de":"Außerhalb des festen Standorts (P)","techniques_de":["Außerhalb des festen Standorts (P)"],"test_object_de":"Drehmomentschraubendreher","methodology_zh":"校准 — 力矩","parameters_zh":[{"name":"","range":"0,2 Nm to 10 Nm","cmc":"1,20 %"}],"regulatory_area_zh":"力矩","search_zh":"扭矩螺丝刀 校准 — 力矩 固定地点以外 (P) 力矩 固定地点以外 (P) PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03","technique_zh":"固定地点以外 (P)","techniques_zh":["固定地点以外 (P)"],"test_object_zh":"扭矩螺丝刀","methodology_cs":"Kalibrace — Moment síly","parameters_cs":[{"name":"","range":"0,2 Nm to 10 Nm","cmc":"1,20 %"}],"regulatory_area_cs":"Moment síly","search_cs":"Momentové šroubováky Kalibrace — Moment síly Mimo stálou lokalitu (P) Moment síly Mimo stálou lokalitu (P) PN-EN ISO/IEC 6789-1:2017-03 PN-EN ISO/IEC 6789-2:2017-03","technique_cs":"Mimo stálou lokalitu (P)","techniques_cs":["Mimo stálou lokalitu (P)"],"test_object_cs":"Momentové šroubováky"},{"_id":"ae485aae9155547b10c97a9b","lab_id":"6af323270ecd48de0c705b88","country":"PL","accr_number":"AP 224","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\n- ciśnienie względne","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges\n- gauge pressure","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"-0,095 MPa do 70 MPa","cmc":"300 Pa"}],"parameters_en":[{"name":"","range":"-0,095 MPa to 70 MPa","cmc":"300 Pa"}],"technique":"Podstawowa procedura wzorcowania, pkt. 5.2.1; Poza stałą lokalizacją (P)","technique_en":"Basic calibration procedure, clause 5.2.1; Outside of permanent location (P)","techniques":["Podstawowa procedura wzorcowania, pkt. 5.2.1","Poza stałą lokalizacją (P)"],"techniques_en":["Basic calibration procedure, clause 5.2.1","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\n-0,095 MPa do 70 MPa CMC 300 Pa\nPodstawowa procedura wzorcowania, pkt. 5.2.1; Poza stałą lokalizacją (P)","reference":"EURAMET Cg-17 v.4.1","norm_bases":["EURAMET Cg-17 v.4.1"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\n- ciśnienie względne Wzorcowanie — Ciśnienie\n-0,095 MPa do 70 MPa CMC 300 Pa\nPodstawowa procedura wzorcowania, pkt. 5.2.1; Poza stałą lokalizacją (P) EURAMET Cg-17 v.4.1 Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne\n- cisnienie wzgledne Wzorcowanie — Cisnienie\n-0,095 MPa do 70 MPa CMC 300 Pa\nPodstawowa procedura wzorcowania, pkt. 5.2.1; Poza stala lokalizacja (P) EURAMET Cg-17 v.4.1","search_en":"Bourdon tube pressure gauges Electronic pressure gauges - gauge pressure Calibration — Pressure Basic calibration procedure, clause 5.2.1; Outside of permanent location (P) Pressure Basic calibration procedure, clause 5.2.1 Outside of permanent location (P) EURAMET Cg-17 v.4.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"-0,095 MPa to 70 MPa","cmc":"300 Pa"}],"regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte - Überdruck Kalibrierung — Druck Grundlegendes Kalibrierverfahren, Pkt. 5.2.1; Außerhalb des festen Standorts (P) Druck Grundlegendes Kalibrierverfahren, Pkt. 5.2.1 Außerhalb des festen Standorts (P) EURAMET Cg-17 v.4.1","technique_de":"Grundlegendes Kalibrierverfahren, Pkt. 5.2.1; Außerhalb des festen Standorts (P)","techniques_de":["Grundlegendes Kalibrierverfahren, Pkt. 5.2.1","Außerhalb des festen Standorts (P)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte\n- Überdruck","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"-0,095 MPa to 70 MPa","cmc":"300 Pa"}],"regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 - 表压 校准 — 压力 基本校准程序，第 5.2.1 条；固定地点以外 (P) 压力 基本校准程序，第 5.2.1 条 固定地点以外 (P) EURAMET Cg-17 v.4.1","technique_zh":"基本校准程序，第 5.2.1 条；固定地点以外 (P)","techniques_zh":["基本校准程序，第 5.2.1 条","固定地点以外 (P)"],"test_object_zh":"弹簧管压力表\n电子压力计\n- 表压","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"-0,095 MPa to 70 MPa","cmc":"300 Pa"}],"regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry - přetlak Kalibrace — Tlak Základní postup kalibrace, bod 5.2.1; Mimo stálou lokalitu (P) Tlak Základní postup kalibrace, bod 5.2.1 Mimo stálou lokalitu (P) EURAMET Cg-17 v.4.1","technique_cs":"Základní postup kalibrace, bod 5.2.1; Mimo stálou lokalitu (P)","techniques_cs":["Základní postup kalibrace, bod 5.2.1","Mimo stálou lokalitu (P)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry\n- přetlak"}],"has_pdf":true}