{"lab":{"_id":"6af323260ecd48de0c705b86","country":"PL","accr_number":"AP 222","imported_at":"2026-11-10T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"Al. Jerozolimskie 56C, 00-803 Warszawa","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"14.11.2024","city":"Warszawa","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. and is expressed in measurand units.","cycle_from":"14.11.2024","cycle_to":"13.11.2028","email_source":"PCA","en_official":true,"fields_of_testing":[{"codes":"10.01","pl":"czas (przedział czasu)","en":"time (time interval)","de":"Zeit (Zeitintervall)","zh":"时间（时间间隔）","cs":"čas (časový interval)"},{"codes":"10.02","pl":"częstotliwość","en":"frequency","de":"Frequenz","zh":"频率","cs":"frekvence"}],"has_en":true,"has_zh":true,"issue":{"no":"2","date":"06.11.2026"},"issue_date":"06.11.2026","issue_number":"2","lab_division":null,"lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[20.9967859,52.2270508]},"map_coord":[52.2270508,20.9967859],"map_geo":"nominatim-street","methods_count":4,"name":"Altaria Calibration Labs Sp. z o.o.","parse_date":"2026-11-10T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-10T12:00:00.000Z","pdf_files":["AP_222.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: czas (przedział czasu), częstotliwość. W stałej lokalizacji (S).","search_text":"altaria calibration labs sp. z o.o. al. jerozolimskie 56c, 00-803 warszawa laboratorium wzorcujące. wielkości mierzone: czas (przedział czasu), częstotliwość. w stałej lokalizacji (s). ap 222 ap222 laboratorium wzorcujące wzorcowanie kalibracja time (time interval) frequency altaria calibration labs sp. z o.o. al. jerozolimskie 56c, 00-803 warszawa laboratorium wzorcujace. wielkosci mierzone: czas (przedzial czasu), czestotliwosc. w stalej lokalizacji (s). ap 222 ap222 laboratorium wzorcujace wzorcowanie kalibracja time (time interval) frequency","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20222,podmiot.html","source_pdf_sha256":"ecf518860dde8a5e030ba756750ddeaa422d81e0b363d01cc5811b356c1eaa7c","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/10/fb18c96f44bdd1025ff38f20c068f675/AP%20222.pdf","status":"active","updated_at":"2026-11-10T12:00:00.000Z","valid_from":"14-11-2024","valid_until":"13-11-2028","website":"","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben.","has_de":true,"cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny.","has_cs":true,"pelny_cs":true},"methods":[{"_id":"723f8c5351386ef2285942cf","lab_id":"6af323260ecd48de0c705b86","country":"PL","accr_number":"AP 222","accr_body":"PCA","test_object":"Mierniki okresu","test_object_en":"Period meters","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"10 ns do 10 ms","cmc":"3,7·10⁻⁵ s/s"},{"name":"","range":"10 ms do 1 s","cmc":"1,5·10⁻¹⁰ s/s"}],"parameters_en":[{"name":"","range":"10 ns to 10 ms","cmc":"3,7·10⁻⁵ s/s"},{"name":"","range":"10 ms to 1 s","cmc":"1,5·10⁻¹⁰ s/s"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nZakres:\n10 ns do 10 ms CMC 3,7·10⁻⁵ s/s\n10 ms do 1 s CMC 1,5·10⁻¹⁰ s/s\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PP-8","norm_bases":["PP-8"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki okresu Wzorcowanie — Czas (przedział czasu)\nZakres:\n10 ns do 10 ms CMC 3,7·10⁻⁵ s/s\n10 ms do 1 s CMC 1,5·10⁻¹⁰ s/s\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PP-8 Mierniki okresu Wzorcowanie — Czas (przedzial czasu)\nZakres:\n10 ns do 10 ms CMC 3,7·10⁻⁵ s/s\n10 ms do 1 s CMC 1,5·10⁻¹⁰ s/s\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PP-8","search_en":"Period meters Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) Time (time interval) Internal procedure Direct method At permanent location (S) PP-8","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"10 ns to 10 ms","cmc":"3,7·10⁻⁵ s/s"},{"name":"","range":"10 ms to 1 s","cmc":"1,5·10⁻¹⁰ s/s"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Periodendauermesser Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) PP-8","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Periodendauermesser","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"10 ns to 10 ms","cmc":"3,7·10⁻⁵ s/s"},{"name":"","range":"10 ms to 1 s","cmc":"1,5·10⁻¹⁰ s/s"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"周期测量仪 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) PP-8","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"周期测量仪","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"10 ns to 10 ms","cmc":"3,7·10⁻⁵ s/s"},{"name":"","range":"10 ms to 1 s","cmc":"1,5·10⁻¹⁰ s/s"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Měřiče periody Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) PP-8","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče periody"},{"_id":"14c783c6d0b406ebe7a6b9fe","lab_id":"6af323260ecd48de0c705b86","country":"PL","accr_number":"AP 222","accr_body":"PCA","test_object":"Nadajniki w analizatorach transmisji PDH","test_object_en":"Transmitters in PDH analyzers","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"1,024 MHz","cmc":"1·10⁻⁹ Hz/Hz"}],"parameters_en":[{"name":"","range":"1,024 MHz","cmc":"1·10⁻⁹ Hz/Hz"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia. Dla przepływności 2048 kb/s (E1); W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method. For throughput 2048 kb/s (E1); At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia. Dla przepływności 2048 kb/s (E1)","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method. For throughput 2048 kb/s (E1)","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n1,024 MHz CMC 1·10⁻⁹ Hz/Hz\nProcedura wewnętrzna; Metoda bezpośrednia. Dla przepływności 2048 kb/s (E1); W stałej lokalizacji (S)","reference":"PP-1","norm_bases":["PP-1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Nadajniki w analizatorach transmisji PDH Wzorcowanie — Częstotliwość\n1,024 MHz CMC 1·10⁻⁹ Hz/Hz\nProcedura wewnętrzna; Metoda bezpośrednia. Dla przepływności 2048 kb/s (E1); W stałej lokalizacji (S) PP-1 Nadajniki w analizatorach transmisji PDH Wzorcowanie — Czestotliwosc\n1,024 MHz CMC 1·10⁻⁹ Hz/Hz\nProcedura wewnetrzna; Metoda bezposrednia. Dla przeplywnosci 2048 kb/s (E1); W stalej lokalizacji (S) PP-1","search_en":"Transmitters in PDH analyzers Calibration — Frequency Internal procedure; Direct method. For throughput 2048 kb/s (E1); At permanent location (S) Frequency Internal procedure Direct method. For throughput 2048 kb/s (E1) At permanent location (S) PP-1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","regulatory_area_de":"Frequenz","search_de":"Sender in PDH-Übertragungsanalysatoren Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren. Für die Bitrate 2048 kb/s (E1); Am festen Standort (S) Frequenz Internes Verfahren Direktes Verfahren. Für die Bitrate 2048 kb/s (E1) Am festen Standort (S) PP-1","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren. Für die Bitrate 2048 kb/s (E1); Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren. Für die Bitrate 2048 kb/s (E1)","Am festen Standort (S)"],"test_object_de":"Sender in PDH-Übertragungsanalysatoren","methodology_zh":"校准 — 频率","regulatory_area_zh":"频率","search_zh":"PDH 传输分析仪中的发射器 校准 — 频率 内部程序；直接法。适用于传输速率 2048 kb/s (E1)；在固定地点 (S) 频率 内部程序 直接法。适用于传输速率 2048 kb/s (E1) 在固定地点 (S) PP-1","technique_zh":"内部程序；直接法。适用于传输速率 2048 kb/s (E1)；在固定地点 (S)","techniques_zh":["内部程序","直接法。适用于传输速率 2048 kb/s (E1)","在固定地点 (S)"],"test_object_zh":"PDH 传输分析仪中的发射器","methodology_cs":"Kalibrace — Kmitočet","regulatory_area_cs":"Frekvence","search_cs":"Vysílače v analyzátorech přenosu PDH Kalibrace — Kmitočet Vnitřní postup; Přímá metoda. Pro přenosovou rychlost 2048 kb/s (E1); Ve stálé lokalitě (S) Frekvence Vnitřní postup Přímá metoda. Pro přenosovou rychlost 2048 kb/s (E1) Ve stálé lokalitě (S) PP-1","technique_cs":"Vnitřní postup; Přímá metoda. Pro přenosovou rychlost 2048 kb/s (E1); Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda. Pro přenosovou rychlost 2048 kb/s (E1)","Ve stálé lokalitě (S)"],"test_object_cs":"Vysílače v analyzátorech přenosu PDH"},{"_id":"1b5783d5a372b093229d3daa","lab_id":"6af323260ecd48de0c705b86","country":"PL","accr_number":"AP 222","accr_body":"PCA","test_object":"Nadajniki w analizatorach transmisji Ethernet","test_object_en":"Transmitters in Ethernet analyzers","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"1 GHz do 100 GHz","cmc":"1·10⁻⁹ Hz/Hz"}],"parameters_en":[{"name":"","range":"1 GHz to 100 GHz","cmc":"1·10⁻⁹ Hz/Hz"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia. Dla przepływności 1GbE, 10GbE, 100GbE; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method. For throughput 1GbE, 10GbE, 100GbE; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia. Dla przepływności 1GbE, 10GbE, 100GbE","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method. For throughput 1GbE, 10GbE, 100GbE","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n1 GHz do 100 GHz CMC 1·10⁻⁹ Hz/Hz\nProcedura wewnętrzna; Metoda bezpośrednia. Dla przepływności 1GbE, 10GbE, 100GbE; W stałej lokalizacji (S)","reference":"PP-2","norm_bases":["PP-2"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Nadajniki w analizatorach transmisji Ethernet Wzorcowanie — Częstotliwość\n1 GHz do 100 GHz CMC 1·10⁻⁹ Hz/Hz\nProcedura wewnętrzna; Metoda bezpośrednia. Dla przepływności 1GbE, 10GbE, 100GbE; W stałej lokalizacji (S) PP-2 Nadajniki w analizatorach transmisji Ethernet Wzorcowanie — Czestotliwosc\n1 GHz do 100 GHz CMC 1·10⁻⁹ Hz/Hz\nProcedura wewnetrzna; Metoda bezposrednia. Dla przeplywnosci 1GbE, 10GbE, 100GbE; W stalej lokalizacji (S) PP-2","search_en":"Transmitters in Ethernet analyzers Calibration — Frequency Internal procedure; Direct method. For throughput 1GbE, 10GbE, 100GbE; At permanent location (S) Frequency Internal procedure Direct method. For throughput 1GbE, 10GbE, 100GbE At permanent location (S) PP-2","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"1 GHz to 100 GHz","cmc":"1·10⁻⁹ Hz/Hz"}],"regulatory_area_de":"Frequenz","search_de":"Sender in Ethernet-Übertragungsanalysatoren Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren. Für die Bitraten 1GbE, 10GbE, 100GbE; Am festen Standort (S) Frequenz Internes Verfahren Direktes Verfahren. Für die Bitraten 1GbE, 10GbE, 100GbE Am festen Standort (S) PP-2","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren. Für die Bitraten 1GbE, 10GbE, 100GbE; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren. Für die Bitraten 1GbE, 10GbE, 100GbE","Am festen Standort (S)"],"test_object_de":"Sender in Ethernet-Übertragungsanalysatoren","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"1 GHz to 100 GHz","cmc":"1·10⁻⁹ Hz/Hz"}],"regulatory_area_zh":"频率","search_zh":"以太网传输分析仪中的发射器 校准 — 频率 内部程序；直接法。适用于传输速率 1GbE、10GbE、100GbE；在固定地点 (S) 频率 内部程序 直接法。适用于传输速率 1GbE、10GbE、100GbE 在固定地点 (S) PP-2","technique_zh":"内部程序；直接法。适用于传输速率 1GbE、10GbE、100GbE；在固定地点 (S)","techniques_zh":["内部程序","直接法。适用于传输速率 1GbE、10GbE、100GbE","在固定地点 (S)"],"test_object_zh":"以太网传输分析仪中的发射器","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"1 GHz to 100 GHz","cmc":"1·10⁻⁹ Hz/Hz"}],"regulatory_area_cs":"Frekvence","search_cs":"Vysílače v analyzátorech přenosu Ethernet Kalibrace — Kmitočet Vnitřní postup; Přímá metoda. Pro přenosové rychlosti 1GbE, 10GbE, 100GbE; Ve stálé lokalitě (S) Frekvence Vnitřní postup Přímá metoda. Pro přenosové rychlosti 1GbE, 10GbE, 100GbE Ve stálé lokalitě (S) PP-2","technique_cs":"Vnitřní postup; Přímá metoda. Pro přenosové rychlosti 1GbE, 10GbE, 100GbE; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda. Pro přenosové rychlosti 1GbE, 10GbE, 100GbE","Ve stálé lokalitě (S)"],"test_object_cs":"Vysílače v analyzátorech přenosu Ethernet"},{"_id":"3a24d73c2f8e40315e12483a","lab_id":"6af323260ecd48de0c705b86","country":"PL","accr_number":"AP 222","accr_body":"PCA","test_object":"Mierniki częstotliwości cyfrowe","test_object_en":"Digital frequency meters","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"1 Hz do 2 GHz","cmc":"1,5·10⁻¹⁰ Hz/Hz"}],"parameters_en":[{"name":"","range":"1 Hz to 2 GHz","cmc":"1,5·10⁻¹⁰ Hz/Hz"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n1 Hz do 2 GHz CMC 1,5·10⁻¹⁰ Hz/Hz\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PP-8","norm_bases":["PP-8"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki częstotliwości cyfrowe Wzorcowanie — Częstotliwość\n1 Hz do 2 GHz CMC 1,5·10⁻¹⁰ Hz/Hz\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PP-8 Mierniki czestotliwosci cyfrowe Wzorcowanie — Czestotliwosc\n1 Hz do 2 GHz CMC 1,5·10⁻¹⁰ Hz/Hz\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PP-8","search_en":"Digital frequency meters Calibration — Frequency Internal procedure; Direct method; At permanent location (S) Frequency Internal procedure Direct method At permanent location (S) PP-8","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"1 Hz to 2 GHz","cmc":"1,5·10⁻¹⁰ Hz/Hz"}],"regulatory_area_de":"Frequenz","search_de":"Digitale Frequenzmesser Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Direktes Verfahren Am festen Standort (S) PP-8","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Digitale Frequenzmesser","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"1 Hz to 2 GHz","cmc":"1,5·10⁻¹⁰ Hz/Hz"}],"regulatory_area_zh":"频率","search_zh":"数字频率计 校准 — 频率 内部程序；直接法；在固定地点 (S) 频率 内部程序 直接法 在固定地点 (S) PP-8","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"数字频率计","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"1 Hz to 2 GHz","cmc":"1,5·10⁻¹⁰ Hz/Hz"}],"regulatory_area_cs":"Frekvence","search_cs":"Digitální čítače kmitočtu Kalibrace — Kmitočet Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Frekvence Vnitřní postup Přímá metoda Ve stálé lokalitě (S) PP-8","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální čítače kmitočtu"}],"has_pdf":true}