{"lab":{"_id":"6af323250ecd48de0c705b85","accr_number":"AP 221","country":"PL","imported_at":"2026-11-10T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Zamenhofa 12a, 90-510 Łódź","approver":"Tadeusz Matras","categories":["metrology"],"certificate_date":"23.06.2025","city":"Łódź","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 %. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The CMC uncertainty expressed as a percentage is the relative measurement uncertainty and refers to the percentage share in the value of the measurand.","cycle_from":"29.12.2023","cycle_to":"28.12.2027","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"15.01","pl":"masa (wagi)","en":"mass (weighing instruments)","de":"Masse (Waagen)","zh":"质量（衡器）","cs":"hmotnost (váhy)"}],"has_en":true,"has_zh":true,"issue":{"no":"6","date":"14.09.2026"},"issue_date":"14.09.2026","issue_number":"6","lab_division":null,"lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[19.452573,51.7617886]},"map_coord":[51.7617886,19.452573],"map_geo":"nominatim-street","methods_count":4,"name":"DARPO Dariusz Potulski","parse_date":"2026-11-10T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-10T12:00:00.000Z","pdf_files":["AP_221.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: masa (wagi). W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"darpo dariusz potulski ul. zamenhofa 12a, 90-510 łódź laboratorium wzorcujące. wielkości mierzone: masa (wagi). w stałej lokalizacji (s) i/lub poza nią (p). ap 221 ap221 laboratorium wzorcujące wzorcowanie kalibracja mass (weighing instruments) darpo dariusz potulski ul. zamenhofa 12a, 90-510 lodz laboratorium wzorcujace. wielkosci mierzone: masa (wagi). w stalej lokalizacji (s) i/lub poza nia (p). ap 221 ap221 laboratorium wzorcujace wzorcowanie kalibracja mass (weighing instruments)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20221,podmiot.html","source_pdf_sha256":"ed46581c765000881945dd15c0f4d9c8fc73bf09f3423717e59a563410954c69","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/10/79a582f3fe02ab274195899ad20fef9b/AP%20221.pdf","status":"active","updated_at":"2026-11-10T12:00:00.000Z","valid_from":"29-12-2023","valid_until":"28-12-2027","website":"www.darpo.pl","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 %. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 %. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"pelny_cs":true},"methods":[{"_id":"302c413e727d7a27a93c6a42","lab_id":"6af323250ecd48de0c705b85","country":"PL","accr_number":"AP 221","accr_body":"PCA","test_object":"Wagi automatyczne dla pojedynczych ładunków","test_object_en":"Automatic catchweighing instruments","methodology":"Wzorcowanie — Masa (wagi)","methodology_en":"Calibration — Mass (weighing instruments)","parameters":[{"name":"","range":"do 30 kg","cmc":"2 · 10⁻² %"}],"parameters_en":[{"name":"","range":"up to 30 kg","cmc":"2 · 10⁻² %"}],"technique":"Poza stałą lokalizacją (P)","technique_en":"Outside of permanent location (P)","techniques":["Poza stałą lokalizacją (P)"],"techniques_en":["Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Masa (wagi)\ndo 30 kg CMC 2 · 10⁻² %\nPoza stałą lokalizacją (P)","reference":"EURAMET cg-26 v.2.0","norm_bases":["EURAMET cg-26 v.2.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Masa (wagi)","regulatory_area_en":"Mass (weighing instruments)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Wagi automatyczne dla pojedynczych ładunków Wzorcowanie — Masa (wagi)\ndo 30 kg CMC 2 · 10⁻² %\nPoza stałą lokalizacją (P) EURAMET cg-26 v.2.0 Wagi automatyczne dla pojedynczych ladunkow Wzorcowanie — Masa (wagi)\ndo 30 kg CMC 2 · 10⁻² %\nPoza stala lokalizacja (P) EURAMET cg-26 v.2.0","search_en":"Automatic catchweighing instruments Calibration — Mass (weighing instruments) Outside of permanent location (P) Mass (weighing instruments) Outside of permanent location (P) EURAMET cg-26 v.2.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Masse (Waagen)","parameters_de":[{"name":"","range":"up to 30 kg","cmc":"2 · 10⁻² %"}],"regulatory_area_de":"Masse (Waagen)","search_de":"Selbsttätige Waagen zum Wägen von Einzellasten (Kontrollwaagen) Kalibrierung — Masse (Waagen) Außerhalb des festen Standorts (P) Masse (Waagen) Außerhalb des festen Standorts (P) EURAMET cg-26 v.2.0","technique_de":"Außerhalb des festen Standorts (P)","techniques_de":["Außerhalb des festen Standorts (P)"],"test_object_de":"Selbsttätige Waagen zum Wägen von Einzellasten (Kontrollwaagen)","methodology_zh":"校准 — 质量（衡器）","parameters_zh":[{"name":"","range":"up to 30 kg","cmc":"2 · 10⁻² %"}],"regulatory_area_zh":"质量（衡器）","search_zh":"单件载荷自动衡器 校准 — 质量（衡器） 固定地点以外 (P) 质量（衡器） 固定地点以外 (P) EURAMET cg-26 v.2.0","technique_zh":"固定地点以外 (P)","techniques_zh":["固定地点以外 (P)"],"test_object_zh":"单件载荷自动衡器","methodology_cs":"Kalibrace — Hmotnost (váhy)","parameters_cs":[{"name":"","range":"up to 30 kg","cmc":"2 · 10⁻² %"}],"regulatory_area_cs":"Hmotnost (váhy)","search_cs":"Váhy s automatickou činností pro jednotlivá břemena Kalibrace — Hmotnost (váhy) Mimo stálou lokalitu (P) Hmotnost (váhy) Mimo stálou lokalitu (P) EURAMET cg-26 v.2.0","technique_cs":"Mimo stálou lokalitu (P)","techniques_cs":["Mimo stálou lokalitu (P)"],"test_object_cs":"Váhy s automatickou činností pro jednotlivá břemena"},{"_id":"b529cc41e879373c30cb2014","lab_id":"6af323250ecd48de0c705b85","country":"PL","accr_number":"AP 221","accr_body":"PCA","test_object":"Wagi automatyczne przenośnikowe","test_object_en":"Continuous totalising automatic weighing instruments (belt weighers)","methodology":"Wzorcowanie — Masa (wagi)","methodology_en":"Calibration — Mass (weighing instruments)","parameters":[{"name":"","range":"do 60000 kg","cmc":"0,11 %"}],"parameters_en":[{"name":"","range":"up to 60000 kg","cmc":"0,11 %"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Masa (wagi)\ndo 60000 kg CMC 0,11 %\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"PW-03 w oparciu o OIML R 50-1:2014 (p.7) OIML R 50-2:2014 (p.10)","norm_bases":["PW-03","OIML R 50-1:2014","OIML R 50-2:2014"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Masa (wagi)","regulatory_area_en":"Mass (weighing instruments)","outside_premises":true,"location_of_activity":"P","note":"Zakres pomiarowy odnosi się do największej masy porcji materiału jednorazowo odważonej na wadze kontrolnej nieautomatycznej","note_en":"The measurement range refers to the maximum mass of a portion of material weighed at one time on a non-automatic control instrument","search_text":"Wagi automatyczne przenośnikowe Wzorcowanie — Masa (wagi)\ndo 60000 kg CMC 0,11 %\nProcedura wewnętrzna; Poza stałą lokalizacją (P) PW-03 w oparciu o OIML R 50-1:2014 (p.7) OIML R 50-2:2014 (p.10) Wagi automatyczne przenosnikowe Wzorcowanie — Masa (wagi)\ndo 60000 kg CMC 0,11 %\nProcedura wewnetrzna; Poza stala lokalizacja (P) PW-03 w oparciu o OIML R 50-1:2014 (p.7) OIML R 50-2:2014 (p.10)","search_en":"Continuous totalising automatic weighing instruments (belt weighers) Calibration — Mass (weighing instruments) Internal procedure; Outside of permanent location (P) Mass (weighing instruments) Internal procedure Outside of permanent location (P) PW-03 based on OIML R 50-1:2014 (p.7) OIML R 50-2:2014 (p.10)","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-03 based on OIML R 50-1:2014 (p.7) OIML R 50-2:2014 (p.10)","methodology_de":"Kalibrierung — Masse (Waagen)","parameters_de":[{"name":"","range":"bis 60000 kg","cmc":"0,11 %"}],"reference_de":"PW-03 auf Grundlage von OIML R 50-1:2014 (Pkt. 7) OIML R 50-2:2014 (Pkt. 10)","regulatory_area_de":"Masse (Waagen)","search_de":"Selbsttätige Förderbandwaagen Kalibrierung — Masse (Waagen) Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Masse (Waagen) Internes Verfahren Außerhalb des festen Standorts (P) PW-03 auf Grundlage von OIML R 50-1:2014 (Pkt. 7) OIML R 50-2:2014 (Pkt. 10)","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Selbsttätige Förderbandwaagen","methodology_zh":"校准 — 质量（衡器）","parameters_zh":[{"name":"","range":"至 60000 kg","cmc":"0,11 %"}],"reference_zh":"PW-03 依据 OIML R 50-1:2014（第7条）OIML R 50-2:2014（第10条）","regulatory_area_zh":"质量（衡器）","search_zh":"自动输送带秤 校准 — 质量（衡器） 内部程序；固定地点以外 (P) 质量（衡器） 内部程序 固定地点以外 (P) PW-03 依据 OIML R 50-1:2014（第7条）OIML R 50-2:2014（第10条）","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"自动输送带秤","methodology_cs":"Kalibrace — Hmotnost (váhy)","parameters_cs":[{"name":"","range":"do 60000 kg","cmc":"0,11 %"}],"reference_cs":"PW-03 na základě OIML R 50-1:2014 (bod 7) OIML R 50-2:2014 (bod 10)","regulatory_area_cs":"Hmotnost (váhy)","search_cs":"Automatické pásové váhy Kalibrace — Hmotnost (váhy) Vnitřní postup; Mimo stálé pracoviště (P) Hmotnost (váhy) Vnitřní postup Mimo stálou lokalitu (P) PW-03 na základě OIML R 50-1:2014 (bod 7) OIML R 50-2:2014 (bod 10)","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Automatické pásové váhy"},{"_id":"8ec204db041e659beac1b095","lab_id":"6af323250ecd48de0c705b85","country":"PL","accr_number":"AP 221","accr_body":"PCA","test_object":"Wagi nieautomatyczne","test_object_en":"Non-automatic weighing instruments","methodology":"Wzorcowanie — Masa (wagi)","methodology_en":"Calibration — Mass (weighing instruments)","parameters":[{"name":"","range":"do 500 g","cmc":"9 · 10⁻⁵ %"},{"name":"","range":"0,5 kg do 10 kg","cmc":"3,9 · 10⁻⁴ %"},{"name":"","range":"10 kg do 35 kg","cmc":"1,4 · 10⁻³ %"},{"name":"","range":"35 kg do 100 kg","cmc":"5,2 · 10⁻³ %"},{"name":"","range":"100 kg do 100000 kg","cmc":"1,3 · 10⁻² %"}],"parameters_en":[{"name":"","range":"up to 500 g","cmc":"9 · 10⁻⁵ %"},{"name":"","range":"0,5 kg do 10 kg","cmc":"3,9 · 10⁻⁴ %"},{"name":"","range":"10 kg do 35 kg","cmc":"1,4 · 10⁻³ %"},{"name":"","range":"35 kg do 100 kg","cmc":"5,2 · 10⁻³ %"},{"name":"","range":"100 kg do 100000 kg","cmc":"1,3 · 10⁻² %"}],"technique":"W stałej lokalizacji (S) i poza nią (P)","technique_en":"At permanent location (S) and outside of it (P)","techniques":["W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Masa (wagi)\nZakres:\ndo 500 g CMC 9 · 10⁻⁵ %\n0,5 kg do 10 kg CMC 3,9 · 10⁻⁴ %\n10 kg do 35 kg CMC 1,4 · 10⁻³ %\n35 kg do 100 kg CMC 5,2 · 10⁻³ %\n100 kg do 100000 kg CMC 1,3 · 10⁻² %\nW stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-18 v.4.0","norm_bases":["EURAMET cg-18 v.4.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Masa (wagi)","regulatory_area_en":"Mass (weighing instruments)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Wagi nieautomatyczne Wzorcowanie — Masa (wagi)\nZakres:\ndo 500 g CMC 9 · 10⁻⁵ %\n0,5 kg do 10 kg CMC 3,9 · 10⁻⁴ %\n10 kg do 35 kg CMC 1,4 · 10⁻³ %\n35 kg do 100 kg CMC 5,2 · 10⁻³ %\n100 kg do 100000 kg CMC 1,3 · 10⁻² %\nW stałej lokalizacji (S) i poza nią (P) EURAMET cg-18 v.4.0 Wagi nieautomatyczne Wzorcowanie — Masa (wagi)\nZakres:\ndo 500 g CMC 9 · 10⁻⁵ %\n0,5 kg do 10 kg CMC 3,9 · 10⁻⁴ %\n10 kg do 35 kg CMC 1,4 · 10⁻³ %\n35 kg do 100 kg CMC 5,2 · 10⁻³ %\n100 kg do 100000 kg CMC 1,3 · 10⁻² %\nW stalej lokalizacji (S) i poza nia (P) EURAMET cg-18 v.4.0","search_en":"Non-automatic weighing instruments Calibration — Mass (weighing instruments) At permanent location (S) and outside of it (P) Mass (weighing instruments) At permanent location (S) and outside of it (P) EURAMET cg-18 v.4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Masse (Waagen)","parameters_de":[{"name":"","range":"bis 500 g","cmc":"9 · 10⁻⁵ %"},{"name":"","range":"0,5 kg do 10 kg","cmc":"3,9 · 10⁻⁴ %"},{"name":"","range":"10 kg do 35 kg","cmc":"1,4 · 10⁻³ %"},{"name":"","range":"35 kg do 100 kg","cmc":"5,2 · 10⁻³ %"},{"name":"","range":"100 kg do 100000 kg","cmc":"1,3 · 10⁻² %"}],"regulatory_area_de":"Masse (Waagen)","search_de":"Nichtselbsttätige Waagen Kalibrierung — Masse (Waagen) Am festen Standort (S) und außerhalb (P) Masse (Waagen) Am festen Standort (S) und außerhalb (P) EURAMET cg-18 v.4.0","technique_de":"Am festen Standort (S) und außerhalb (P)","techniques_de":["Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Nichtselbsttätige Waagen","methodology_zh":"校准 — 质量（衡器）","parameters_zh":[{"name":"","range":"至 500 g","cmc":"9 · 10⁻⁵ %"},{"name":"","range":"0,5 kg do 10 kg","cmc":"3,9 · 10⁻⁴ %"},{"name":"","range":"10 kg do 35 kg","cmc":"1,4 · 10⁻³ %"},{"name":"","range":"35 kg do 100 kg","cmc":"5,2 · 10⁻³ %"},{"name":"","range":"100 kg do 100000 kg","cmc":"1,3 · 10⁻² %"}],"regulatory_area_zh":"质量（衡器）","search_zh":"非自动衡器 校准 — 质量（衡器） 在固定地点 (S) 及固定地点以外 (P) 质量（衡器） 在固定地点 (S) 及固定地点以外 (P) EURAMET cg-18 v.4.0","technique_zh":"在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"非自动衡器","methodology_cs":"Kalibrace — Hmotnost (váhy)","parameters_cs":[{"name":"","range":"do 500 g","cmc":"9 · 10⁻⁵ %"},{"name":"","range":"0,5 kg do 10 kg","cmc":"3,9 · 10⁻⁴ %"},{"name":"","range":"10 kg do 35 kg","cmc":"1,4 · 10⁻³ %"},{"name":"","range":"35 kg do 100 kg","cmc":"5,2 · 10⁻³ %"},{"name":"","range":"100 kg do 100000 kg","cmc":"1,3 · 10⁻² %"}],"regulatory_area_cs":"Hmotnost (váhy)","search_cs":"Váhy s neautomatickou činností Kalibrace — Hmotnost (váhy) V trvalé lokalitě (S) i mimo ni (P) Hmotnost (váhy) V trvalé lokalitě (S) i mimo ni (P) EURAMET cg-18 v.4.0","technique_cs":"V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Váhy s neautomatickou činností"},{"_id":"b3463966bcf659748a1dd869","lab_id":"6af323250ecd48de0c705b85","country":"PL","accr_number":"AP 221","accr_body":"PCA","test_object":"Wagi nieautomatyczne","test_object_en":"Non-automatic weighing instruments","methodology":"Wzorcowanie — Masa (wagi)","methodology_en":"Calibration — Mass (weighing instruments)","parameters":[{"name":"","range":"1000 kg do 100000 kg","cmc":"4,5 · 10⁻² %"}],"parameters_en":[{"name":"","range":"1000 kg to 100000 kg","cmc":"4,5 · 10⁻² %"}],"technique":"Metoda przy użyciu materiału zastępczego; Poza stałą lokalizacją (P)","technique_en":"Method using substitution material; Outside of permanent location (P)","techniques":["Metoda przy użyciu materiału zastępczego","Poza stałą lokalizacją (P)"],"techniques_en":["Method using substitution material","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Masa (wagi)\n1000 kg do 100000 kg CMC 4,5 · 10⁻² %\nMetoda przy użyciu materiału zastępczego; Poza stałą lokalizacją (P)","reference":"EURAMET cg-18 v.4.0","norm_bases":["EURAMET cg-18 v.4.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Masa (wagi)","regulatory_area_en":"Mass (weighing instruments)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Wagi nieautomatyczne Wzorcowanie — Masa (wagi)\n1000 kg do 100000 kg CMC 4,5 · 10⁻² %\nMetoda przy użyciu materiału zastępczego; Poza stałą lokalizacją (P) EURAMET cg-18 v.4.0 Wagi nieautomatyczne Wzorcowanie — Masa (wagi)\n1000 kg do 100000 kg CMC 4,5 · 10⁻² %\nMetoda przy uzyciu materialu zastepczego; Poza stala lokalizacja (P) EURAMET cg-18 v.4.0","search_en":"Non-automatic weighing instruments Calibration — Mass (weighing instruments) Method using substitution material; Outside of permanent location (P) Mass (weighing instruments) Method using substitution material Outside of permanent location (P) EURAMET cg-18 v.4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Masse (Waagen)","parameters_de":[{"name":"","range":"1000 kg to 100000 kg","cmc":"4,5 · 10⁻² %"}],"regulatory_area_de":"Masse (Waagen)","search_de":"Nichtselbsttätige Waagen Kalibrierung — Masse (Waagen) Verfahren mit Ersatzmaterial; Außerhalb des festen Standorts (P) Masse (Waagen) Verfahren mit Ersatzmaterial Außerhalb des festen Standorts (P) EURAMET cg-18 v.4.0","technique_de":"Verfahren mit Ersatzmaterial; Außerhalb des festen Standorts (P)","techniques_de":["Verfahren mit Ersatzmaterial","Außerhalb des festen Standorts (P)"],"test_object_de":"Nichtselbsttätige Waagen","methodology_zh":"校准 — 质量（衡器）","parameters_zh":[{"name":"","range":"1000 kg to 100000 kg","cmc":"4,5 · 10⁻² %"}],"regulatory_area_zh":"质量（衡器）","search_zh":"非自动衡器 校准 — 质量（衡器） 使用替代材料的方法；固定地点以外 (P) 质量（衡器） 使用替代材料的方法 固定地点以外 (P) EURAMET cg-18 v.4.0","technique_zh":"使用替代材料的方法；固定地点以外 (P)","techniques_zh":["使用替代材料的方法","固定地点以外 (P)"],"test_object_zh":"非自动衡器","methodology_cs":"Kalibrace — Hmotnost (váhy)","parameters_cs":[{"name":"","range":"1000 kg to 100000 kg","cmc":"4,5 · 10⁻² %"}],"regulatory_area_cs":"Hmotnost (váhy)","search_cs":"Váhy s neautomatickou činností Kalibrace — Hmotnost (váhy) Metoda s použitím náhradního materiálu; Mimo stálé prostory (P) Hmotnost (váhy) Metoda s použitím náhradního materiálu Mimo stálou lokalitu (P) EURAMET cg-18 v.4.0","technique_cs":"Metoda s použitím náhradního materiálu; Mimo stálé prostory (P)","techniques_cs":["Metoda s použitím náhradního materiálu","Mimo stálou lokalitu (P)"],"test_object_cs":"Váhy s neautomatickou činností"}],"has_pdf":true}