{"lab":{"_id":"6ae132f2ff068247617088cb","accr_number":"AP 192","country":"PL","imported_at":"2026-10-27T12:00:00.000Z","accr_body":"PCA","activity_conducted":"poza lokalizacją (P)","activity_conducted_en":"outside of permanent location (P)","address":"ul. Warszawska 100/102, 05-092 Łomianki","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"10.06.2020","city":"Łomianki","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units.","cycle_from":"06.06.2024","cycle_to":"09.06.2028","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"14.02","pl":"wilgotność względna","en":"relative humidity"},{"codes":"19.01","pl":"temperatura (termometria elektryczna)","en":"temperature (electrical thermometry)"}],"has_en":true,"has_zh":false,"issue":{"no":"5","date":"23.03.2026"},"issue_date":"23.03.2026","issue_number":"5","lab_division":"Laboratorium Wzorcujące SPECTRO-LAB","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[20.9020058,52.332209]},"map_coord":[52.332209,20.9020058],"map_geo":"nominatim-street","methods_count":2,"name":"SPECTRO-LAB Sp. z o.o.","parse_date":"2026-10-27T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-10-27T12:00:00.000Z","pdf_files":["AP_192.pdf"],"scope_notes":[{"pl":"1) Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania.","en":"1) The CMC measurement uncertainty value applies to a single measuring point in the space of the calibrated object."}],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: wilgotność względna, temperatura (termometria elektryczna). Poza lokalizacją (P).","search_text":"spectro-lab sp. z o.o. laboratorium wzorcujące spectro-lab ul. warszawska 100/102, 05-092 łomianki laboratorium wzorcujące. wielkości mierzone: wilgotność względna, temperatura (termometria elektryczna). poza lokalizacją (p). ap 192 ap192 laboratorium wzorcujące wzorcowanie kalibracja relative humidity temperature (electrical thermometry) spectro-lab sp. z o.o. laboratorium wzorcujace spectro-lab ul. warszawska 100/102, 05-092 lomianki laboratorium wzorcujace. wielkosci mierzone: wilgotnosc wzgledna, temperatura (termometria elektryczna). poza lokalizacja (p). ap 192 ap192 laboratorium wzorcujace wzorcowanie kalibracja relative humidity temperature (electrical thermometry)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20192,podmiot.html","source_pdf_sha256":"247d61a5cd4609f4e28219b461ef6a31aed90189467a6a5b49193338dce5139f","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/10/27/28ab15a4d87ad6dbc6e6df36f6acdf1c/AP%20192.pdf","status":"active","updated_at":"2026-10-27T12:00:00.000Z","valid_from":"10-06-2020","valid_until":"09-06-2028","website":"www.spectro-lab.pl"},"methods":[{"_id":"6c202d8fe62f97749d997e4a","lab_id":"6ae132f2ff068247617088cb","country":"PL","accr_number":"AP 192","accr_body":"PCA","test_object":"Komory klimatyczne","test_object_en":"Climatic chambers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"zakres temperatur 20 °C do 90 °C","range":"20 %rh do 98 %rh","cmc":"3,0 %rh"}],"parameters_en":[{"name":"temperature range 20 °C to 90 °C","range":"20 %rh to 98 %rh","cmc":"3,0 %rh"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nzakres temperatur 20 °C do 90 °C 20 %rh do 98 %rh CMC 3,0 %rh\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"PW-01 w oparciu o EURAMET cg-20 v. 5.0","norm_bases":["PW-01","EURAMET cg-20 v. 5.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Komory klimatyczne Wzorcowanie — Wilgotność względna\nzakres temperatur 20 °C do 90 °C 20 %rh do 98 %rh CMC 3,0 %rh\nProcedura wewnętrzna; Poza stałą lokalizacją (P) PW-01 w oparciu o EURAMET cg-20 v. 5.0 Komory klimatyczne Wzorcowanie — Wilgotnosc wzgledna\nzakres temperatur 20 °C do 90 °C 20 %rh do 98 %rh CMC 3,0 %rh\nProcedura wewnetrzna; Poza stala lokalizacja (P) PW-01 w oparciu o EURAMET cg-20 v. 5.0","search_en":"Climatic chambers Calibration — Relative humidity\ntemperature range 20 °C to 90 °C 20 %rh to 98 %rh CMC 3,0 %rh\nInternal procedure; Outside of permanent location (P) PW-01 w oparciu o EURAMET cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1"},{"_id":"7cebf00fd21d65b3168632ae","lab_id":"6ae132f2ff068247617088cb","country":"PL","accr_number":"AP 192","accr_body":"PCA","test_object":"Komory klimatyczne\nKomory termostatyczne","test_object_en":"Climatic chambers\nThermostatic chambers","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-70 °C do -40 °C","cmc":"0,4 °C (dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania)"},{"name":"","range":"-40 °C do 120 °C","cmc":"0,3 °C"},{"name":"","range":"120 °C do 180 °C","cmc":"0,3 °C (dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania)"},{"name":"","range":"180 °C do 300 °C","cmc":"0,5 °C (dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania)"}],"parameters_en":[{"name":"","range":"-70 °C to -40 °C","cmc":"0,4 °C (applies to a single measuring point in the space of the calibrated object)"},{"name":"","range":"-40 °C to 120 °C","cmc":"0,3 °C"},{"name":"","range":"120 °C to 180 °C","cmc":"0,3 °C (applies to a single measuring point in the space of the calibrated object)"},{"name":"","range":"180 °C to 300 °C","cmc":"0,5 °C (applies to a single measuring point in the space of the calibrated object)"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-70 °C do -40 °C CMC 0,4 °C (dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania)\n-40 °C do 120 °C CMC 0,3 °C\n120 °C do 180 °C CMC 0,3 °C (dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania)\n180 °C do 300 °C CMC 0,5 °C (dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania)\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"PW-01 w oparciu o EURAMET cg-20 v. 5.0","norm_bases":["PW-01","EURAMET cg-20 v. 5.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":"dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania","note_en":"applies to a single measuring point in the space of the calibrated object","search_text":"Komory klimatyczne\nKomory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-70 °C do -40 °C CMC 0,4 °C (dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania)\n-40 °C do 120 °C CMC 0,3 °C\n120 °C do 180 °C CMC 0,3 °C (dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania)\n180 °C do 300 °C CMC 0,5 °C (dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania)\nProcedura wewnętrzna; Poza stałą lokalizacją (P) PW-01 w oparciu o EURAMET cg-20 v. 5.0 Komory klimatyczne\nKomory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-70 °C do -40 °C CMC 0,4 °C (dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania)\n-40 °C do 120 °C CMC 0,3 °C\n120 °C do 180 °C CMC 0,3 °C (dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania)\n180 °C do 300 °C CMC 0,5 °C (dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania)\nProcedura wewnetrzna; Poza stala lokalizacja (P) PW-01 w oparciu o EURAMET cg-20 v. 5.0","search_en":"Climatic chambers\nThermostatic chambers Calibration — Temperature (electrical thermometry)\nScope:\n-70 °C to -40 °C CMC 0,4 °C (applies to a single measuring point in the space of the calibrated object)\n-40 °C to 120 °C CMC 0,3 °C\n120 °C to 180 °C CMC 0,3 °C (applies to a single measuring point in the space of the calibrated object)\n180 °C to 300 °C CMC 0,5 °C (applies to a single measuring point in the space of the calibrated object)\nInternal procedure; Outside of permanent location (P) PW-01 w oparciu o EURAMET cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1"}],"has_pdf":true}