{"lab":{"_id":"6ae132efff068247617088c3","country":"PL","accr_number":"AP 174","imported_at":"2026-10-27T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"Sadków 9, 26-600 Radom","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"23.10.2019","city":"Radom","cmc_note":"Niepewność pomiaru CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 %. Niepewność pomiaru CMC wyrażona jest w jednostkach wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The CMC uncertainty is expressed in measurand units.","cycle_from":"25.09.2025","cycle_to":"11.10.2029","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"17.01","pl":"ciśnienie","en":"pressure"}],"has_en":true,"has_zh":false,"issue":{"no":"7","date":"25.09.2025"},"issue_date":"25.09.2025","issue_number":"7","lab_division":null,"lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[21.2072406,51.3964213]},"map_coord":[51.3964213,21.2072406],"map_geo":"nominatim-street","methods_count":1,"name":"4 Wojskowy Ośrodek Metrologii","parse_date":"2026-10-27T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-10-27T12:00:00.000Z","pdf_files":["AP_174.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: ciśnienie. W stałej lokalizacji (S).","search_text":"4 wojskowy ośrodek metrologii sadków 9, 26-600 radom laboratorium wzorcujące. wielkości mierzone: ciśnienie. w stałej lokalizacji (s). ap 174 ap174 laboratorium wzorcujące wzorcowanie kalibracja pressure 4 wojskowy osrodek metrologii sadkow 9, 26-600 radom laboratorium wzorcujace. wielkosci mierzone: cisnienie. w stalej lokalizacji (s). ap 174 ap174 laboratorium wzorcujace wzorcowanie kalibracja pressure","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20174,podmiot.html","source_pdf_sha256":"37d04f421276ebfabd3dd610cf375e7e02501c80ee11796487f4e238881c5712","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/10/27/020dfe36683710c1805b3503f7525477/AP%20174.pdf","status":"active","updated_at":"2026-10-27T12:00:00.000Z","valid_from":"12-10-2017","valid_until":"11-10-2029","website":"metrologia.wp.mil.pl"},"methods":[{"_id":"48390ab737b6fc6b767fc3b5","lab_id":"6ae132efff068247617088c3","country":"PL","accr_number":"AP 174","accr_body":"PCA","test_object":"Wysokościomierze barometryczne","test_object_en":"Barometric altimeters","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"ciśnienie absolutne (gaz)","range":"190 mmHg do 800 mmHg","cmc":"0,65 mmHg"}],"parameters_en":[{"name":"absolute pressure (gas)","range":"190 mmHg to 800 mmHg","cmc":"0,65 mmHg"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nciśnienie absolutne (gaz) 190 mmHg do 800 mmHg CMC 0,65 mmHg\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PP-15.03.03-8-2022-4WOM-WYSOKOŚCIOMIERZE_BAR w oparciu o EURAMET cg-17 v.4.1","norm_bases":["PP-15.03.03-8-2022-4WOM-WYSOKOŚCIOMIERZE_BAR","EURAMET cg-17 v.4.1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wysokościomierze barometryczne Wzorcowanie — Ciśnienie\nciśnienie absolutne (gaz) 190 mmHg do 800 mmHg CMC 0,65 mmHg\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PP-15.03.03-8-2022-4WOM-WYSOKOŚCIOMIERZE_BAR w oparciu o EURAMET cg-17 v.4.1 Wysokosciomierze barometryczne Wzorcowanie — Cisnienie\ncisnienie absolutne (gaz) 190 mmHg do 800 mmHg CMC 0,65 mmHg\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PP-15.03.03-8-2022-4WOM-WYSOKOSCIOMIERZE_BAR w oparciu o EURAMET cg-17 v.4.1","search_en":"Barometric altimeters Calibration — Pressure\nabsolute pressure (gas) 190 mmHg to 800 mmHg CMC 0,65 mmHg\nInternal procedure; Direct method; At permanent location (S) PP-15.03.03-8-2022-4WOM-WYSOKOŚCIOMIERZE_BAR w oparciu o EURAMET cg-17 v.4.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1"}],"has_pdf":true}