{"lab":{"_id":"6afa3b9a8989a133b76445c6","accr_number":"AP 171","country":"PL","imported_at":"2026-11-15T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"ul. Wólczyńska 133, bud. 5, lok. 54i , 01-919 Warszawa","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"05.11.2024","city":"Warszawa","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.","cycle_from":"07.01.2025","cycle_to":"15.01.2029","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"6.01","pl":"długość","en":"length","de":"Länge","zh":"长度","cs":"délka"},{"codes":"6.02","pl":"kąt","en":"angle","de":"Winkel","zh":"角度","cs":"úhel"},{"codes":"6.03","pl":"długość (geometria powierzchni)","en":"length (surface geometry)","de":"Länge (Oberflächengeometrie)","zh":"长度（表面几何）","cs":"délka (geometrie povrchu)"},{"codes":"12.01","pl":"siła","en":"force","de":"Kraft","zh":"力","cs":"síla"},{"codes":"12.02","pl":"moment siły","en":"torque","de":"Drehmoment","zh":"力矩","cs":"moment síly"}],"has_en":true,"has_zh":true,"issue":{"no":"11","date":"17.10.2025"},"issue_date":"17.10.2025","issue_number":"11","lab_division":null,"lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[20.9150269,52.2826944]},"map_coord":[52.2826944,20.9150269],"map_geo":"nominatim-street","methods_count":75,"name":"LAB MESK Spółka Cywilna Marcin Tokaj Magdalena Tokaj","parse_date":"2026-11-15T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-15T12:00:00.000Z","pdf_files":["AP_171.pdf"],"scope_notes":[{"pl":"Wartość niepewności pomiaru dla CMC wyrażona w postaci równania Q[a; b] oznacza pierwiastek sumy kwadratów wyrazów w nawiasach: Q[a; b] = (a² + b²)^1/2.","en":"A CMC uncertainty value expressed as Q[a; b] means the root sum of squares of the terms in brackets: Q[a; b] = (a² + b²)^1/2."}],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: długość, kąt, długość (geometria powierzchni), siła, moment siły. W stałej lokalizacji (S).","search_text":"lab mesk spółka cywilna marcin tokaj magdalena tokaj ul. wólczyńska 133, bud. 5, lok. 54i , 01-919 warszawa laboratorium wzorcujące. wielkości mierzone: długość, kąt, długość (geometria powierzchni), siła, moment siły. w stałej lokalizacji (s). ap 171 ap171 laboratorium wzorcujące wzorcowanie kalibracja length angle length (surface geometry) force torque lab mesk spolka cywilna marcin tokaj magdalena tokaj ul. wolczynska 133, bud. 5, lok. 54i , 01-919 warszawa laboratorium wzorcujace. wielkosci mierzone: dlugosc, kat, dlugosc (geometria powierzchni), sila, moment sily. w stalej lokalizacji (s). ap 171 ap171 laboratorium wzorcujace wzorcowanie kalibracja length angle length (surface geometry) force torque","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20171,podmiot.html","source_pdf_sha256":"96e4e81075e0548f19ae667debaef47ba8e4da0f2985c35d369cfcae3be31be6","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/15/66e2fcbb139b1dd735e2e7895343f882/AP%20171.pdf","status":"active","updated_at":"2026-11-15T12:00:00.000Z","valid_from":"16-01-2017","valid_until":"15-01-2029","website":"www.labmesk.pl","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"pelny_cs":true},"methods":[{"_id":"29057744dcc48ab8fbd35729","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Czujniki analogowe o wartości działki elementarnej 0,1 mm","test_object_en":"Analogue dial gauges with a scale interval of 0,1 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 30 mm","cmc":"9 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"10 µm"}],"parameters_en":[{"name":"","range":"0 mm do 30 mm","cmc":"9 µm"},{"name":"","range":"0 mm to 50 mm","cmc":"10 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Mahr Precimar ICM 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 30 mm CMC 9 µm\n0 mm do 50 mm CMC 10 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.49","norm_bases":["IW5.8.49"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe o wartości działki elementarnej 0,1 mm Wzorcowanie — Długość\nZakres:\n0 mm do 30 mm CMC 9 µm\n0 mm do 50 mm CMC 10 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.49 Czujniki analogowe o wartosci dzialki elementarnej 0,1 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 30 mm CMC 9 µm\n0 mm do 50 mm CMC 10 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu Mahr Precimar ICM 100; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.49","search_en":"Analogue dial gauges with a scale interval of 0,1 mm Calibration — Length Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S) Length Internal procedure Direct method using the Mahr Precimar ICM 100 instrument At permanent location (S) Internal procedure IW5.8.49","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.49","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 30 mm","cmc":"9 µm"},{"name":"","range":"0 mm bis 50 mm","cmc":"10 µm"}],"reference_de":"Internes Verfahren IW5.8.49","regulatory_area_de":"Länge","search_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,1 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100 Am festen Standort (S) Internes Verfahren IW5.8.49","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,1 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 30 mm","cmc":"9 µm"},{"name":"","range":"0 mm 至 50 mm","cmc":"10 µm"}],"reference_zh":"内部程序 IW5.8.49","regulatory_area_zh":"长度","search_zh":"分度值 0,1 mm 的模拟指示表 校准 — 长度 内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用Mahr Precimar ICM 100仪器的直接法 在固定地点 (S) 内部程序 IW5.8.49","technique_zh":"内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mahr Precimar ICM 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"分度值 0,1 mm 的模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 30 mm","cmc":"9 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"10 µm"}],"reference_cs":"Vnitřní postup IW5.8.49","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry s hodnotou dílku 0,1 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje Mahr Precimar ICM 100 Ve stálé lokalitě (S) Vnitřní postup IW5.8.49","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje Mahr Precimar ICM 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry s hodnotou dílku 0,1 mm"},{"_id":"3bd85e05dbace247a1ebb232","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Czujniki analogowe o wartości działki elementarnej 0,01 mm","test_object_en":"Analogue dial gauges with a scale interval of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"1,2 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,8 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,7 µm"}],"parameters_en":[{"name":"","range":"0 mm do 10 mm","cmc":"1,2 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,8 µm"},{"name":"","range":"0 mm to 50 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,7 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Mahr Precimar ICM 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 1,2 µm\n0 mm do 30 mm CMC 1,8 µm\n0 mm do 50 mm CMC 2,5 µm\n0 mm do 100 mm CMC 4,7 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.49","norm_bases":["IW5.8.49"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe o wartości działki elementarnej 0,01 mm Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 1,2 µm\n0 mm do 30 mm CMC 1,8 µm\n0 mm do 50 mm CMC 2,5 µm\n0 mm do 100 mm CMC 4,7 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.49 Czujniki analogowe o wartosci dzialki elementarnej 0,01 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 10 mm CMC 1,2 µm\n0 mm do 30 mm CMC 1,8 µm\n0 mm do 50 mm CMC 2,5 µm\n0 mm do 100 mm CMC 4,7 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu Mahr Precimar ICM 100; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.49","search_en":"Analogue dial gauges with a scale interval of 0,01 mm Calibration — Length Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S) Length Internal procedure Direct method using the Mahr Precimar ICM 100 instrument At permanent location (S) Internal procedure IW5.8.49","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.49","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 10 mm","cmc":"1,2 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,8 µm"},{"name":"","range":"0 mm bis 50 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,7 µm"}],"reference_de":"Internes Verfahren IW5.8.49","regulatory_area_de":"Länge","search_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,01 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100 Am festen Standort (S) Internes Verfahren IW5.8.49","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 10 mm","cmc":"1,2 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,8 µm"},{"name":"","range":"0 mm 至 50 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,7 µm"}],"reference_zh":"内部程序 IW5.8.49","regulatory_area_zh":"长度","search_zh":"分度值 0,01 mm 的模拟指示表 校准 — 长度 内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用Mahr Precimar ICM 100仪器的直接法 在固定地点 (S) 内部程序 IW5.8.49","technique_zh":"内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mahr Precimar ICM 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"分度值 0,01 mm 的模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 10 mm","cmc":"1,2 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,8 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,7 µm"}],"reference_cs":"Vnitřní postup IW5.8.49","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry s hodnotou dílku 0,01 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje Mahr Precimar ICM 100 Ve stálé lokalitě (S) Vnitřní postup IW5.8.49","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje Mahr Precimar ICM 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry s hodnotou dílku 0,01 mm"},{"_id":"b4ebc2fc2cae4f9738f3a4ff","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Czujniki analogowe o wartości działki elementarnej 0,005 mm","test_object_en":"Analogue dial gauges with a scale interval of 0,005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 5 mm","cmc":"0,8 µm"}],"parameters_en":[{"name":"","range":"0 mm to 5 mm","cmc":"0,8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Mahr Precimar ICM 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 5 mm CMC 0,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.49","norm_bases":["IW5.8.49"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe o wartości działki elementarnej 0,005 mm Wzorcowanie — Długość\n0 mm do 5 mm CMC 0,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.49 Czujniki analogowe o wartosci dzialki elementarnej 0,005 mm Wzorcowanie — Dlugosc\n0 mm do 5 mm CMC 0,8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu Mahr Precimar ICM 100; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.49","search_en":"Analogue dial gauges with a scale interval of 0,005 mm Calibration — Length Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S) Length Internal procedure Direct method using the Mahr Precimar ICM 100 instrument At permanent location (S) Internal procedure IW5.8.49","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.49","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 5 mm","cmc":"0,8 µm"}],"reference_de":"Internes Verfahren IW5.8.49","regulatory_area_de":"Länge","search_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,005 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100 Am festen Standort (S) Internes Verfahren IW5.8.49","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 5 mm","cmc":"0,8 µm"}],"reference_zh":"内部程序 IW5.8.49","regulatory_area_zh":"长度","search_zh":"分度值 0,005 mm 的模拟指示表 校准 — 长度 内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用Mahr Precimar ICM 100仪器的直接法 在固定地点 (S) 内部程序 IW5.8.49","technique_zh":"内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mahr Precimar ICM 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"分度值 0,005 mm 的模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 5 mm","cmc":"0,8 µm"}],"reference_cs":"Vnitřní postup IW5.8.49","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry s hodnotou dílku 0,005 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje Mahr Precimar ICM 100 Ve stálé lokalitě (S) Vnitřní postup IW5.8.49","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje Mahr Precimar ICM 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry s hodnotou dílku 0,005 mm"},{"_id":"bfc57b619a136e4e5613654e","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Czujniki analogowe o wartości działki elementarnej 0,002 mm","test_object_en":"Analogue dial gauges with a scale interval of 0,002 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 1 mm","cmc":"0,7 µm"}],"parameters_en":[{"name":"","range":"0 mm to 1 mm","cmc":"0,7 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Mahr Precimar ICM 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 1 mm CMC 0,7 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.49","norm_bases":["IW5.8.49"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe o wartości działki elementarnej 0,002 mm Wzorcowanie — Długość\n0 mm do 1 mm CMC 0,7 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.49 Czujniki analogowe o wartosci dzialki elementarnej 0,002 mm Wzorcowanie — Dlugosc\n0 mm do 1 mm CMC 0,7 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu Mahr Precimar ICM 100; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.49","search_en":"Analogue dial gauges with a scale interval of 0,002 mm Calibration — Length Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S) Length Internal procedure Direct method using the Mahr Precimar ICM 100 instrument At permanent location (S) Internal procedure IW5.8.49","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.49","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 1 mm","cmc":"0,7 µm"}],"reference_de":"Internes Verfahren IW5.8.49","regulatory_area_de":"Länge","search_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,002 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100 Am festen Standort (S) Internes Verfahren IW5.8.49","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,002 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 1 mm","cmc":"0,7 µm"}],"reference_zh":"内部程序 IW5.8.49","regulatory_area_zh":"长度","search_zh":"分度值 0,002 mm 的模拟指示表 校准 — 长度 内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用Mahr Precimar ICM 100仪器的直接法 在固定地点 (S) 内部程序 IW5.8.49","technique_zh":"内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mahr Precimar ICM 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"分度值 0,002 mm 的模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 1 mm","cmc":"0,7 µm"}],"reference_cs":"Vnitřní postup IW5.8.49","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry s hodnotou dílku 0,002 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje Mahr Precimar ICM 100 Ve stálé lokalitě (S) Vnitřní postup IW5.8.49","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje Mahr Precimar ICM 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry s hodnotou dílku 0,002 mm"},{"_id":"ef1a4e5bfffae3a8a30afee0","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Czujniki analogowe o wartości działki elementarnej 0,001 mm","test_object_en":"Analogue dial gauges with a scale interval of 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 1 mm","cmc":"0,6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 1 mm","cmc":"0,6 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Mahr Precimar ICM 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 1 mm CMC 0,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.49","norm_bases":["IW5.8.49"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe o wartości działki elementarnej 0,001 mm Wzorcowanie — Długość\n0 mm do 1 mm CMC 0,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.49 Czujniki analogowe o wartosci dzialki elementarnej 0,001 mm Wzorcowanie — Dlugosc\n0 mm do 1 mm CMC 0,6 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu Mahr Precimar ICM 100; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.49","search_en":"Analogue dial gauges with a scale interval of 0,001 mm Calibration — Length Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S) Length Internal procedure Direct method using the Mahr Precimar ICM 100 instrument At permanent location (S) Internal procedure IW5.8.49","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.49","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 1 mm","cmc":"0,6 µm"}],"reference_de":"Internes Verfahren IW5.8.49","regulatory_area_de":"Länge","search_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,001 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100 Am festen Standort (S) Internes Verfahren IW5.8.49","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 1 mm","cmc":"0,6 µm"}],"reference_zh":"内部程序 IW5.8.49","regulatory_area_zh":"长度","search_zh":"分度值 0,001 mm 的模拟指示表 校准 — 长度 内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用Mahr Precimar ICM 100仪器的直接法 在固定地点 (S) 内部程序 IW5.8.49","technique_zh":"内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mahr Precimar ICM 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"分度值 0,001 mm 的模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 1 mm","cmc":"0,6 µm"}],"reference_cs":"Vnitřní postup IW5.8.49","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry s hodnotou dílku 0,001 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje Mahr Precimar ICM 100 Ve stálé lokalitě (S) Vnitřní postup IW5.8.49","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje Mahr Precimar ICM 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry s hodnotou dílku 0,001 mm"},{"_id":"27cbd88c1ef8ea73a9e28f50","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Czujniki analogowe z uchylnym trzpieniem o wartości działki elementarnej 0,01 mm","test_object_en":"Lever-type analogue dial gauges with a scale interval of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 3 mm","cmc":"1,2 µm"}],"parameters_en":[{"name":"","range":"0 mm to 3 mm","cmc":"1,2 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Mahr Precimar ICM 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 3 mm CMC 1,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.49","norm_bases":["IW5.8.49"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe z uchylnym trzpieniem o wartości działki elementarnej 0,01 mm Wzorcowanie — Długość\n0 mm do 3 mm CMC 1,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.49 Czujniki analogowe z uchylnym trzpieniem o wartosci dzialki elementarnej 0,01 mm Wzorcowanie — Dlugosc\n0 mm do 3 mm CMC 1,2 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu Mahr Precimar ICM 100; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.49","search_en":"Lever-type analogue dial gauges with a scale interval of 0,01 mm Calibration — Length Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S) Length Internal procedure Direct method using the Mahr Precimar ICM 100 instrument At permanent location (S) Internal procedure IW5.8.49","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.49","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 3 mm","cmc":"1,2 µm"}],"reference_de":"Internes Verfahren IW5.8.49","regulatory_area_de":"Länge","search_de":"Analoge Fühlhebelmessgeräte mit einem Skalenteilungswert von 0,01 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100 Am festen Standort (S) Internes Verfahren IW5.8.49","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100","Am festen Standort (S)"],"test_object_de":"Analoge Fühlhebelmessgeräte mit einem Skalenteilungswert von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 3 mm","cmc":"1,2 µm"}],"reference_zh":"内部程序 IW5.8.49","regulatory_area_zh":"长度","search_zh":"分度值 0,01 mm的模拟式杠杆指示表 校准 — 长度 内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用Mahr Precimar ICM 100仪器的直接法 在固定地点 (S) 内部程序 IW5.8.49","technique_zh":"内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mahr Precimar ICM 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"分度值 0,01 mm的模拟式杠杆指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 3 mm","cmc":"1,2 µm"}],"reference_cs":"Vnitřní postup IW5.8.49","regulatory_area_cs":"Délka","search_cs":"Analogové páčkové úchylkoměry s hodnotou dílku 0,01 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje Mahr Precimar ICM 100 Ve stálé lokalitě (S) Vnitřní postup IW5.8.49","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje Mahr Precimar ICM 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové páčkové úchylkoměry s hodnotou dílku 0,01 mm"},{"_id":"eca885ad48b9e3a83808a8bd","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Czujniki analogowe z uchylnym trzpieniem o wartości działki elementarnej 0,002 mm; 0,001 mm","test_object_en":"Lever-type analogue dial gauges with a scale interval of 0,002 mm; 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 0,6 mm","cmc":"0,8 µm"}],"parameters_en":[{"name":"","range":"0 mm to 0,6 mm","cmc":"0,8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Mahr Precimar ICM 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 0,6 mm CMC 0,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.49","norm_bases":["IW5.8.49"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe z uchylnym trzpieniem o wartości działki elementarnej 0,002 mm; 0,001 mm Wzorcowanie — Długość\n0 mm do 0,6 mm CMC 0,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.49 Czujniki analogowe z uchylnym trzpieniem o wartosci dzialki elementarnej 0,002 mm; 0,001 mm Wzorcowanie — Dlugosc\n0 mm do 0,6 mm CMC 0,8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu Mahr Precimar ICM 100; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.49","search_en":"Lever-type analogue dial gauges with a scale interval of 0,002 mm; 0,001 mm Calibration — Length Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S) Length Internal procedure Direct method using the Mahr Precimar ICM 100 instrument At permanent location (S) Internal procedure IW5.8.49","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.49","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 0,6 mm","cmc":"0,8 µm"}],"reference_de":"Internes Verfahren IW5.8.49","regulatory_area_de":"Länge","search_de":"Analoge Fühlhebelmessgeräte mit einem Skalenteilungswert von 0,002 mm; 0,001 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100 Am festen Standort (S) Internes Verfahren IW5.8.49","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100","Am festen Standort (S)"],"test_object_de":"Analoge Fühlhebelmessgeräte mit einem Skalenteilungswert von 0,002 mm; 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 0,6 mm","cmc":"0,8 µm"}],"reference_zh":"内部程序 IW5.8.49","regulatory_area_zh":"长度","search_zh":"分度值 0,002 mm的模拟式杠杆指示表；0,001 mm 校准 — 长度 内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用Mahr Precimar ICM 100仪器的直接法 在固定地点 (S) 内部程序 IW5.8.49","technique_zh":"内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mahr Precimar ICM 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"分度值 0,002 mm的模拟式杠杆指示表；0,001 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 0,6 mm","cmc":"0,8 µm"}],"reference_cs":"Vnitřní postup IW5.8.49","regulatory_area_cs":"Délka","search_cs":"Analogové páčkové úchylkoměry s hodnotou dílku 0,002 mm; 0,001 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje Mahr Precimar ICM 100 Ve stálé lokalitě (S) Vnitřní postup IW5.8.49","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje Mahr Precimar ICM 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové páčkové úchylkoměry s hodnotou dílku 0,002 mm; 0,001 mm"},{"_id":"07528ca7b37c67922e2bd7c8","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,01 mm","test_object_en":"Digital dial gauges with a resolution of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50,8 mm","cmc":"9 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"10 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50,8 mm","cmc":"9 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"10 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Mahr Precimar ICM 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 50,8 mm CMC 9 µm\n0 mm do 100 mm CMC 10 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.49","norm_bases":["IW5.8.49"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,01 mm Wzorcowanie — Długość\nZakres:\n0 mm do 50,8 mm CMC 9 µm\n0 mm do 100 mm CMC 10 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.49 Czujniki cyfrowe o rozdzielczosci 0,01 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 50,8 mm CMC 9 µm\n0 mm do 100 mm CMC 10 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu Mahr Precimar ICM 100; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.49","search_en":"Digital dial gauges with a resolution of 0,01 mm Calibration — Length Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S) Length Internal procedure Direct method using the Mahr Precimar ICM 100 instrument At permanent location (S) Internal procedure IW5.8.49","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.49","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50,8 mm","cmc":"9 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"10 µm"}],"reference_de":"Internes Verfahren IW5.8.49","regulatory_area_de":"Länge","search_de":"Digitale Messtaster mit einer Auflösung von 0,01 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100 Am festen Standort (S) Internes Verfahren IW5.8.49","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100","Am festen Standort (S)"],"test_object_de":"Digitale Messtaster mit einer Auflösung von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50,8 mm","cmc":"9 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"10 µm"}],"reference_zh":"内部程序 IW5.8.49","regulatory_area_zh":"长度","search_zh":"分辨率 0,01 mm 的数字测微表 校准 — 长度 内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用Mahr Precimar ICM 100仪器的直接法 在固定地点 (S) 内部程序 IW5.8.49","technique_zh":"内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mahr Precimar ICM 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"分辨率 0,01 mm 的数字测微表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50,8 mm","cmc":"9 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"10 µm"}],"reference_cs":"Vnitřní postup IW5.8.49","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,01 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje Mahr Precimar ICM 100 Ve stálé lokalitě (S) Vnitřní postup IW5.8.49","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje Mahr Precimar ICM 100","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,01 mm"},{"_id":"daf2158b7a7dc71778a1488f","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,005 mm","test_object_en":"Digital dial gauges with a resolution of 0,005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50,8 mm","cmc":"5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50,8 mm","cmc":"5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"6 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Mahr Precimar ICM 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 50,8 mm CMC 5 µm\n0 mm do 100 mm CMC 6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.49","norm_bases":["IW5.8.49"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,005 mm Wzorcowanie — Długość\nZakres:\n0 mm do 50,8 mm CMC 5 µm\n0 mm do 100 mm CMC 6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.49 Czujniki cyfrowe o rozdzielczosci 0,005 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 50,8 mm CMC 5 µm\n0 mm do 100 mm CMC 6 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu Mahr Precimar ICM 100; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.49","search_en":"Digital dial gauges with a resolution of 0,005 mm Calibration — Length Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S) Length Internal procedure Direct method using the Mahr Precimar ICM 100 instrument At permanent location (S) Internal procedure IW5.8.49","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.49","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50,8 mm","cmc":"5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"6 µm"}],"reference_de":"Internes Verfahren IW5.8.49","regulatory_area_de":"Länge","search_de":"Digitale Messuhren mit einer Auflösung von 0,005 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100 Am festen Standort (S) Internes Verfahren IW5.8.49","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren mit einer Auflösung von 0,005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50,8 mm","cmc":"5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"6 µm"}],"reference_zh":"内部程序 IW5.8.49","regulatory_area_zh":"长度","search_zh":"分辨力 0,005 mm 的数显指示表 校准 — 长度 内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用Mahr Precimar ICM 100仪器的直接法 在固定地点 (S) 内部程序 IW5.8.49","technique_zh":"内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mahr Precimar ICM 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"分辨力 0,005 mm 的数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50,8 mm","cmc":"5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"6 µm"}],"reference_cs":"Vnitřní postup IW5.8.49","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,005 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje Mahr Precimar ICM 100 Ve stálé lokalitě (S) Vnitřní postup IW5.8.49","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje Mahr Precimar ICM 100","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,005 mm"},{"_id":"2a5a4e4f48114ebc5ca83716","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,001 mm","test_object_en":"Digital dial gauges with a resolution of 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,6 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,7 µm"}],"parameters_en":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,6 µm"},{"name":"","range":"0 mm to 50,8 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,7 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Mahr Precimar ICM 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 1,3 µm\n0 mm do 25,4 mm CMC 1,6 µm\n0 mm do 50,8 mm CMC 2,5 µm\n0 mm do 100 mm CMC 4,7 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.49","norm_bases":["IW5.8.49"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,001 mm Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 1,3 µm\n0 mm do 25,4 mm CMC 1,6 µm\n0 mm do 50,8 mm CMC 2,5 µm\n0 mm do 100 mm CMC 4,7 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.49 Czujniki cyfrowe o rozdzielczosci 0,001 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 12,7 mm CMC 1,3 µm\n0 mm do 25,4 mm CMC 1,6 µm\n0 mm do 50,8 mm CMC 2,5 µm\n0 mm do 100 mm CMC 4,7 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu Mahr Precimar ICM 100; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.49","search_en":"Digital dial gauges with a resolution of 0,001 mm Calibration — Length Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S) Length Internal procedure Direct method using the Mahr Precimar ICM 100 instrument At permanent location (S) Internal procedure IW5.8.49","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.49","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,6 µm"},{"name":"","range":"0 mm bis 50,8 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,7 µm"}],"reference_de":"Internes Verfahren IW5.8.49","regulatory_area_de":"Länge","search_de":"Digitale Messuhren mit einer Auflösung von 0,001 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100 Am festen Standort (S) Internes Verfahren IW5.8.49","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren mit einer Auflösung von 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,6 µm"},{"name":"","range":"0 mm 至 50,8 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,7 µm"}],"reference_zh":"内部程序 IW5.8.49","regulatory_area_zh":"长度","search_zh":"分辨力 0,001 mm 的数显指示表 校准 — 长度 内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用Mahr Precimar ICM 100仪器的直接法 在固定地点 (S) 内部程序 IW5.8.49","technique_zh":"内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mahr Precimar ICM 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"分辨力 0,001 mm 的数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,6 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,7 µm"}],"reference_cs":"Vnitřní postup IW5.8.49","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,001 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje Mahr Precimar ICM 100 Ve stálé lokalitě (S) Vnitřní postup IW5.8.49","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje Mahr Precimar ICM 100","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,001 mm"},{"_id":"46bc2af6718acbee7f25f76e","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,0001 mm","test_object_en":"Digital dial gauges with a resolution of 0,0001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,0 µm"}],"parameters_en":[{"name":"","range":"0 mm to 12,7 mm","cmc":"1,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Mahr Precimar ICM 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 12,7 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.49","norm_bases":["IW5.8.49"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,0001 mm Wzorcowanie — Długość\n0 mm do 12,7 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mahr Precimar ICM 100; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.49 Czujniki cyfrowe o rozdzielczosci 0,0001 mm Wzorcowanie — Dlugosc\n0 mm do 12,7 mm CMC 1,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu Mahr Precimar ICM 100; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.49","search_en":"Digital dial gauges with a resolution of 0,0001 mm Calibration — Length Internal procedure; Direct method using the Mahr Precimar ICM 100 instrument; At permanent location (S) Length Internal procedure Direct method using the Mahr Precimar ICM 100 instrument At permanent location (S) Internal procedure IW5.8.49","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.49","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 12,7 mm","cmc":"1,0 µm"}],"reference_de":"Internes Verfahren IW5.8.49","regulatory_area_de":"Länge","search_de":"Digitale Messuhren mit einer Auflösung von 0,0001 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100 Am festen Standort (S) Internes Verfahren IW5.8.49","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Gerät Mahr Precimar ICM 100","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren mit einer Auflösung von 0,0001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 12,7 mm","cmc":"1,0 µm"}],"reference_zh":"内部程序 IW5.8.49","regulatory_area_zh":"长度","search_zh":"分辨力 0,0001 mm 的数显指示表 校准 — 长度 内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用Mahr Precimar ICM 100仪器的直接法 在固定地点 (S) 内部程序 IW5.8.49","technique_zh":"内部程序；使用Mahr Precimar ICM 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mahr Precimar ICM 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"分辨力 0,0001 mm 的数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 12,7 mm","cmc":"1,0 µm"}],"reference_cs":"Vnitřní postup IW5.8.49","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,0001 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje Mahr Precimar ICM 100 Ve stálé lokalitě (S) Vnitřní postup IW5.8.49","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje Mahr Precimar ICM 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje Mahr Precimar ICM 100","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,0001 mm"},{"_id":"037c0dc3b2c92ee348084ff2","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Czujniki optyczne","test_object_en":"Optical probes","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"± 20 µm","cmc":"0,12 µm"},{"name":"","range":"± 100 µm","cmc":"0,13 µm"}],"parameters_en":[{"name":"","range":"± 20 µm","cmc":"0,12 µm"},{"name":"","range":"± 100 µm","cmc":"0,13 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n± 20 µm CMC 0,12 µm\n± 100 µm CMC 0,13 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.19","norm_bases":["IW5.8.19"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki optyczne Wzorcowanie — Długość\nZakres:\n± 20 µm CMC 0,12 µm\n± 100 µm CMC 0,13 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.19 Czujniki optyczne Wzorcowanie — Dlugosc\nZakres:\n± 20 µm CMC 0,12 µm\n± 100 µm CMC 0,13 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.19","search_en":"Optical probes Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.19","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.19","methodology_de":"Kalibrierung — Länge","reference_de":"Internes Verfahren IW5.8.19","regulatory_area_de":"Länge","search_de":"Optische Messtaster Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.19","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Optische Messtaster","methodology_zh":"校准 — 长度","reference_zh":"内部程序 IW5.8.19","regulatory_area_zh":"长度","search_zh":"光学测头 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.19","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"光学测头","methodology_cs":"Kalibrace — Délka","reference_cs":"Vnitřní postup IW5.8.19","regulatory_area_cs":"Délka","search_cs":"Optické snímače Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.19","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Optické snímače"},{"_id":"de6ac4d9ff6ef77b9f882d59","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Długościomierze poziome Abbego","test_object_en":"Abbe horizontal length measuring machines","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 100 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"0,5 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 100 mm CMC 0,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.8","norm_bases":["IW5.8.8"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Długościomierze poziome Abbego Wzorcowanie — Długość\n0 mm do 100 mm CMC 0,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.8 Dlugosciomierze poziome Abbego Wzorcowanie — Dlugosc\n0 mm do 100 mm CMC 0,5 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.8","search_en":"Abbe horizontal length measuring machines Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.8","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.8","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 100 mm","cmc":"0,5 µm"}],"reference_de":"Internes Verfahren IW5.8.8","regulatory_area_de":"Länge","search_de":"Horizontale Abbe-Längenmessgeräte Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.8","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Horizontale Abbe-Längenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 100 mm","cmc":"0,5 µm"}],"reference_zh":"内部程序 IW5.8.8","regulatory_area_zh":"长度","search_zh":"卧式阿贝测长仪 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.8","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"卧式阿贝测长仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 100 mm","cmc":"0,5 µm"}],"reference_cs":"Vnitřní postup IW5.8.8","regulatory_area_cs":"Délka","search_cs":"Horizontální Abbeovy délkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.8","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Horizontální Abbeovy délkoměry"},{"_id":"f0b65bd96ce9020b77d366ed","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Folie wzorcowe","test_object_en":"Reference foils","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 1 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm do 2 mm","cmc":"5,5 µm"},{"name":"","range":"0 mm do 3 mm","cmc":"8,2 µm"},{"name":"","range":"0 mm do 4 mm","cmc":"10,9 µm"},{"name":"","range":"0 mm do 5 mm","cmc":"13,6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 1 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm to 2 mm","cmc":"5,5 µm"},{"name":"","range":"0 mm to 3 mm","cmc":"8,2 µm"},{"name":"","range":"0 mm to 4 mm","cmc":"10,9 µm"},{"name":"","range":"0 mm to 5 mm","cmc":"13,6 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza poziomego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a horizontal length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza poziomego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a horizontal length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 1 mm CMC 2,9 µm\n0 mm do 2 mm CMC 5,5 µm\n0 mm do 3 mm CMC 8,2 µm\n0 mm do 4 mm CMC 10,9 µm\n0 mm do 5 mm CMC 13,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza poziomego; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.30","norm_bases":["IW5.8.30"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Folie wzorcowe Wzorcowanie — Długość\nZakres:\n0 mm do 1 mm CMC 2,9 µm\n0 mm do 2 mm CMC 5,5 µm\n0 mm do 3 mm CMC 8,2 µm\n0 mm do 4 mm CMC 10,9 µm\n0 mm do 5 mm CMC 13,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza poziomego; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.30 Folie wzorcowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 1 mm CMC 2,9 µm\n0 mm do 2 mm CMC 5,5 µm\n0 mm do 3 mm CMC 8,2 µm\n0 mm do 4 mm CMC 10,9 µm\n0 mm do 5 mm CMC 13,6 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza poziomego; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.30","search_en":"Reference foils Calibration — Length Internal procedure; Direct method using a horizontal length measuring machine; At permanent location (S) Length Internal procedure Direct method using a horizontal length measuring machine At permanent location (S) Internal procedure IW5.8.30","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.30","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 1 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm to 2 mm","cmc":"5,5 µm"},{"name":"","range":"0 mm to 3 mm","cmc":"8,2 µm"},{"name":"","range":"0 mm to 4 mm","cmc":"10,9 µm"},{"name":"","range":"0 mm to 5 mm","cmc":"13,6 µm"}],"reference_de":"Internes Verfahren IW5.8.30","regulatory_area_de":"Länge","search_de":"Referenzfolien Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Horizontal-Längenmessgerät; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Horizontal-Längenmessgerät Am festen Standort (S) Internes Verfahren IW5.8.30","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Horizontal-Längenmessgerät; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Horizontal-Längenmessgerät","Am festen Standort (S)"],"test_object_de":"Referenzfolien","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 1 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm to 2 mm","cmc":"5,5 µm"},{"name":"","range":"0 mm to 3 mm","cmc":"8,2 µm"},{"name":"","range":"0 mm to 4 mm","cmc":"10,9 µm"},{"name":"","range":"0 mm to 5 mm","cmc":"13,6 µm"}],"reference_zh":"内部程序 IW5.8.30","regulatory_area_zh":"长度","search_zh":"标准薄膜 校准 — 长度 内部程序；使用卧式测长仪的直接法；在固定地点 (S) 长度 内部程序 使用卧式测长仪的直接法 在固定地点 (S) 内部程序 IW5.8.30","technique_zh":"内部程序；使用卧式测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用卧式测长仪的直接法","在固定地点 (S)"],"test_object_zh":"标准薄膜","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 1 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm to 2 mm","cmc":"5,5 µm"},{"name":"","range":"0 mm to 3 mm","cmc":"8,2 µm"},{"name":"","range":"0 mm to 4 mm","cmc":"10,9 µm"},{"name":"","range":"0 mm to 5 mm","cmc":"13,6 µm"}],"reference_cs":"Vnitřní postup IW5.8.30","regulatory_area_cs":"Délka","search_cs":"Etalonové fólie Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím vodorovného délkoměru; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím vodorovného délkoměru Ve stálé lokalitě (S) Vnitřní postup IW5.8.30","technique_cs":"Vnitřní postup; Přímá metoda s použitím vodorovného délkoměru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím vodorovného délkoměru","Ve stálé lokalitě (S)"],"test_object_cs":"Etalonové fólie"},{"_id":"61c0ebbbd40e5eb0cecdd2b9","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Głębokościomierze czujnikowe o rozdzielczości 0,001 mm","test_object_en":"Dial depth gauges with a resolution of 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 5 mm","cmc":"0,3 µm"},{"name":"","range":"0 mm do 10 mm","cmc":"0,9 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"1,7 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"2,9 µm"}],"parameters_en":[{"name":"","range":"0 mm do 5 mm","cmc":"0,3 µm"},{"name":"","range":"0 mm do 10 mm","cmc":"0,9 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm to 50 mm","cmc":"1,7 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"2,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 5 mm CMC 0,3 µm\n0 mm do 10 mm CMC 0,9 µm\n0 mm do 30 mm CMC 1,3 µm\n0 mm do 50 mm CMC 1,7 µm\n0 mm do 100 mm CMC 2,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.16","norm_bases":["IW5.8.16"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze czujnikowe o rozdzielczości 0,001 mm Wzorcowanie — Długość\nZakres:\n0 mm do 5 mm CMC 0,3 µm\n0 mm do 10 mm CMC 0,9 µm\n0 mm do 30 mm CMC 1,3 µm\n0 mm do 50 mm CMC 1,7 µm\n0 mm do 100 mm CMC 2,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.16 Glebokosciomierze czujnikowe o rozdzielczosci 0,001 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 5 mm CMC 0,3 µm\n0 mm do 10 mm CMC 0,9 µm\n0 mm do 30 mm CMC 1,3 µm\n0 mm do 50 mm CMC 1,7 µm\n0 mm do 100 mm CMC 2,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.16","search_en":"Dial depth gauges with a resolution of 0,001 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.16","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.16","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 5 mm","cmc":"0,3 µm"},{"name":"","range":"0 mm do 10 mm","cmc":"0,9 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm bis 50 mm","cmc":"1,7 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"2,9 µm"}],"reference_de":"Internes Verfahren IW5.8.16","regulatory_area_de":"Länge","search_de":"Tiefenmessuhren mit einer Auflösung von 0,001 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.16","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Tiefenmessuhren mit einer Auflösung von 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 5 mm","cmc":"0,3 µm"},{"name":"","range":"0 mm do 10 mm","cmc":"0,9 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm 至 50 mm","cmc":"1,7 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"2,9 µm"}],"reference_zh":"内部程序 IW5.8.16","regulatory_area_zh":"长度","search_zh":"分辨率 0,001 mm 的指示式深度尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.16","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"分辨率 0,001 mm 的指示式深度尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 5 mm","cmc":"0,3 µm"},{"name":"","range":"0 mm do 10 mm","cmc":"0,9 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"1,7 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"2,9 µm"}],"reference_cs":"Vnitřní postup IW5.8.16","regulatory_area_cs":"Délka","search_cs":"Hloubkoměry s úchylkoměrem s rozlišením 0,001 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.16","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Hloubkoměry s úchylkoměrem s rozlišením 0,001 mm"},{"_id":"2dc8bdaace35deba8e0a87c3","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Głębokościomierze czujnikowe o rozdzielczości 0,002 mm, 0,005 mm","test_object_en":"Dial depth gauges with a resolution of 0,002 mm, 0,005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 5 mm","cmc":"0,3 µm"}],"parameters_en":[{"name":"","range":"0 mm to 5 mm","cmc":"0,3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 5 mm CMC 0,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.16","norm_bases":["IW5.8.16"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze czujnikowe o rozdzielczości 0,002 mm, 0,005 mm Wzorcowanie — Długość\n0 mm do 5 mm CMC 0,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.16 Glebokosciomierze czujnikowe o rozdzielczosci 0,002 mm, 0,005 mm Wzorcowanie — Dlugosc\n0 mm do 5 mm CMC 0,3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.16","search_en":"Dial depth gauges with a resolution of 0,002 mm, 0,005 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.16","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.16","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 5 mm","cmc":"0,3 µm"}],"reference_de":"Internes Verfahren IW5.8.16","regulatory_area_de":"Länge","search_de":"Tiefenmessuhren mit einer Auflösung von 0,002 mm, 0,005 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.16","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Tiefenmessuhren mit einer Auflösung von 0,002 mm, 0,005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 5 mm","cmc":"0,3 µm"}],"reference_zh":"内部程序 IW5.8.16","regulatory_area_zh":"长度","search_zh":"分辨力 0,002 mm、0,005 mm 的指示式深度尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.16","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"分辨力 0,002 mm、0,005 mm 的指示式深度尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 5 mm","cmc":"0,3 µm"}],"reference_cs":"Vnitřní postup IW5.8.16","regulatory_area_cs":"Délka","search_cs":"Hloubkoměry s úchylkoměrem s rozlišením 0,002 mm, 0,005 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.16","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Hloubkoměry s úchylkoměrem s rozlišením 0,002 mm, 0,005 mm"},{"_id":"f4e645482bf85b8af0227463","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Głębokościomierze czujnikowe o rozdzielczości 0,01 mm","test_object_en":"Dial depth gauges with a resolution of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"6,6 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"7,0 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"6,6 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"7,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 6,6 µm\n0 mm do 100 mm CMC 7,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.16","norm_bases":["IW5.8.16"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze czujnikowe o rozdzielczości 0,01 mm Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 6,6 µm\n0 mm do 100 mm CMC 7,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.16 Glebokosciomierze czujnikowe o rozdzielczosci 0,01 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 50 mm CMC 6,6 µm\n0 mm do 100 mm CMC 7,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.16","search_en":"Dial depth gauges with a resolution of 0,01 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.16","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.16","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"6,6 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"7,0 µm"}],"reference_de":"Internes Verfahren IW5.8.16","regulatory_area_de":"Länge","search_de":"Tiefenmessuhren mit einer Auflösung von 0,01 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.16","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Tiefenmessuhren mit einer Auflösung von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"6,6 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"7,0 µm"}],"reference_zh":"内部程序 IW5.8.16","regulatory_area_zh":"长度","search_zh":"分辨率 0,01 mm 的指示式深度尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.16","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"分辨率 0,01 mm 的指示式深度尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"6,6 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"7,0 µm"}],"reference_cs":"Vnitřní postup IW5.8.16","regulatory_area_cs":"Délka","search_cs":"Hloubkoměry s úchylkoměrem s rozlišením 0,01 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.16","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Hloubkoměry s úchylkoměrem s rozlišením 0,01 mm"},{"_id":"9782d4c35bda5c7a01f0cae1","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Głębokościomierze czujnikowe o wartości działki elementarnej 0,01 mm","test_object_en":"Dial depth gauges with a scale interval of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"0,9 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"1,7 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"2,9 µm"}],"parameters_en":[{"name":"","range":"0 mm do 10 mm","cmc":"0,9 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm to 50 mm","cmc":"1,7 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"2,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 0,9 µm\n0 mm do 30 mm CMC 1,3 µm\n0 mm do 50 mm CMC 1,7 µm\n0 mm do 100 mm CMC 2,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.16","norm_bases":["IW5.8.16"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze czujnikowe o wartości działki elementarnej 0,01 mm Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 0,9 µm\n0 mm do 30 mm CMC 1,3 µm\n0 mm do 50 mm CMC 1,7 µm\n0 mm do 100 mm CMC 2,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.16 Glebokosciomierze czujnikowe o wartosci dzialki elementarnej 0,01 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 10 mm CMC 0,9 µm\n0 mm do 30 mm CMC 1,3 µm\n0 mm do 50 mm CMC 1,7 µm\n0 mm do 100 mm CMC 2,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.16","search_en":"Dial depth gauges with a scale interval of 0,01 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.16","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.16","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 10 mm","cmc":"0,9 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm bis 50 mm","cmc":"1,7 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"2,9 µm"}],"reference_de":"Internes Verfahren IW5.8.16","regulatory_area_de":"Länge","search_de":"Tiefenmessuhren mit einem Skalenteilungswert von 0,01 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.16","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Tiefenmessuhren mit einem Skalenteilungswert von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 10 mm","cmc":"0,9 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm 至 50 mm","cmc":"1,7 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"2,9 µm"}],"reference_zh":"内部程序 IW5.8.16","regulatory_area_zh":"长度","search_zh":"分度值 0,01 mm 的指示式深度尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.16","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"分度值 0,01 mm 的指示式深度尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 10 mm","cmc":"0,9 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"1,7 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"2,9 µm"}],"reference_cs":"Vnitřní postup IW5.8.16","regulatory_area_cs":"Délka","search_cs":"Hloubkoměry s úchylkoměrem s hodnotou dílku 0,01 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.16","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Hloubkoměry s úchylkoměrem s hodnotou dílku 0,01 mm"},{"_id":"da643697486b764b9e8e920b","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Głębokościomierze czujnikowe o wartości działki elementarnej 0,1 mm","test_object_en":"Dial depth gauges with a scale interval of 0,1 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"6,6 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"7,0 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"6,6 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"7,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 6,6 µm\n0 mm do 100 mm CMC 7,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.16","norm_bases":["IW5.8.16"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze czujnikowe o wartości działki elementarnej 0,1 mm Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 6,6 µm\n0 mm do 100 mm CMC 7,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.16 Glebokosciomierze czujnikowe o wartosci dzialki elementarnej 0,1 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 50 mm CMC 6,6 µm\n0 mm do 100 mm CMC 7,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.16","search_en":"Dial depth gauges with a scale interval of 0,1 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.16","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.16","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"6,6 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"7,0 µm"}],"reference_de":"Internes Verfahren IW5.8.16","regulatory_area_de":"Länge","search_de":"Tiefenmessuhren mit einem Skalenteilungswert von 0,1 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.16","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Tiefenmessuhren mit einem Skalenteilungswert von 0,1 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"6,6 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"7,0 µm"}],"reference_zh":"内部程序 IW5.8.16","regulatory_area_zh":"长度","search_zh":"分度值 0,1 mm 的指示式深度尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.16","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"分度值 0,1 mm 的指示式深度尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"6,6 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"7,0 µm"}],"reference_cs":"Vnitřní postup IW5.8.16","regulatory_area_cs":"Délka","search_cs":"Hloubkoměry s úchylkoměrem s hodnotou dílku 0,1 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.16","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Hloubkoměry s úchylkoměrem s hodnotou dílku 0,1 mm"},{"_id":"3f53dd7bafd08e55f0039408","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Głębokościomierze mikrometryczne","test_object_en":"Micrometer depth gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 25 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"2,9 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"3,7 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"4,3 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"4,9 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"5,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,2 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"6,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,1 µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm to 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm to 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"2,9 µm"},{"name":"","range":"100 mm to 125 mm","cmc":"3,7 µm"},{"name":"","range":"125 mm to 150 mm","cmc":"4,3 µm"},{"name":"","range":"150 mm to 175 mm","cmc":"4,9 µm"},{"name":"","range":"175 mm to 200 mm","cmc":"5,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,2 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"6,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,1 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 1,1 µm\n25 mm do 50 mm CMC 1,6 µm\n50 mm do 75 mm CMC 2,2 µm\n75 mm do 100 mm CMC 2,9 µm\n100 mm do 125 mm CMC 3,7 µm\n125 mm do 150 mm CMC 4,3 µm\n150 mm do 175 mm CMC 4,9 µm\n175 mm do 200 mm CMC 5,5 µm\n200 mm do 225 mm CMC 6,2 µm\n225 mm do 250 mm CMC 6,8 µm\n250 mm do 275 mm CMC 7,5 µm\n275 mm do 300 mm CMC 8,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.17","norm_bases":["IW5.8.17"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze mikrometryczne Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 1,1 µm\n25 mm do 50 mm CMC 1,6 µm\n50 mm do 75 mm CMC 2,2 µm\n75 mm do 100 mm CMC 2,9 µm\n100 mm do 125 mm CMC 3,7 µm\n125 mm do 150 mm CMC 4,3 µm\n150 mm do 175 mm CMC 4,9 µm\n175 mm do 200 mm CMC 5,5 µm\n200 mm do 225 mm CMC 6,2 µm\n225 mm do 250 mm CMC 6,8 µm\n250 mm do 275 mm CMC 7,5 µm\n275 mm do 300 mm CMC 8,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.17 Glebokosciomierze mikrometryczne Wzorcowanie — Dlugosc\nZakres:\n0 mm do 25 mm CMC 1,1 µm\n25 mm do 50 mm CMC 1,6 µm\n50 mm do 75 mm CMC 2,2 µm\n75 mm do 100 mm CMC 2,9 µm\n100 mm do 125 mm CMC 3,7 µm\n125 mm do 150 mm CMC 4,3 µm\n150 mm do 175 mm CMC 4,9 µm\n175 mm do 200 mm CMC 5,5 µm\n200 mm do 225 mm CMC 6,2 µm\n225 mm do 250 mm CMC 6,8 µm\n250 mm do 275 mm CMC 7,5 µm\n275 mm do 300 mm CMC 8,1 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.17","search_en":"Micrometer depth gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.17","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":19,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.17","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 25 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm bis 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm bis 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"2,9 µm"},{"name":"","range":"100 mm bis 125 mm","cmc":"3,7 µm"},{"name":"","range":"125 mm bis 150 mm","cmc":"4,3 µm"},{"name":"","range":"150 mm bis 175 mm","cmc":"4,9 µm"},{"name":"","range":"175 mm bis 200 mm","cmc":"5,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,2 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"6,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,1 µm"}],"reference_de":"Internes Verfahren IW5.8.17","regulatory_area_de":"Länge","search_de":"Mikrometer-Tiefenmessgeräte Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.17","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Mikrometer-Tiefenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm 至 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm 至 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"2,9 µm"},{"name":"","range":"100 mm 至 125 mm","cmc":"3,7 µm"},{"name":"","range":"125 mm 至 150 mm","cmc":"4,3 µm"},{"name":"","range":"150 mm 至 175 mm","cmc":"4,9 µm"},{"name":"","range":"175 mm 至 200 mm","cmc":"5,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,2 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"6,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,1 µm"}],"reference_zh":"内部程序 IW5.8.17","regulatory_area_zh":"长度","search_zh":"深度千分尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.17","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"深度千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 25 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"2,9 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"3,7 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"4,3 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"4,9 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"5,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,2 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"6,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,1 µm"}],"reference_cs":"Vnitřní postup IW5.8.17","regulatory_area_cs":"Délka","search_cs":"Mikrometrické hloubkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.17","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometrické hloubkoměry"},{"_id":"b3571d0edd766a15886ad9e6","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Głębokościomierze suwmiarkowe","test_object_en":"Vernier depth gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 150 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 200 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"}],"parameters_en":[{"name":"","range":"0 mm do 150 mm","cmc":"10 µm"},{"name":"","range":"0 mm to 200 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 10 µm\n0 mm do 200 mm CMC 10 µm\n0 mm do 300 mm CMC 12 µm\n0 mm do 500 mm CMC 17 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.3","norm_bases":["IW5.8.3"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze suwmiarkowe Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 10 µm\n0 mm do 200 mm CMC 10 µm\n0 mm do 300 mm CMC 12 µm\n0 mm do 500 mm CMC 17 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.3 Glebokosciomierze suwmiarkowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 150 mm CMC 10 µm\n0 mm do 200 mm CMC 10 µm\n0 mm do 300 mm CMC 12 µm\n0 mm do 500 mm CMC 17 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.3","search_en":"Vernier depth gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.3","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":20,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.3","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 150 mm","cmc":"10 µm"},{"name":"","range":"0 mm bis 200 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"}],"reference_de":"Internes Verfahren IW5.8.3","regulatory_area_de":"Länge","search_de":"Tiefenmessschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.3","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Tiefenmessschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 150 mm","cmc":"10 µm"},{"name":"","range":"0 mm 至 200 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"}],"reference_zh":"内部程序 IW5.8.3","regulatory_area_zh":"长度","search_zh":"深度游标卡尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.3","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"深度游标卡尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 150 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 200 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"}],"reference_cs":"Vnitřní postup IW5.8.3","regulatory_area_cs":"Délka","search_cs":"Posuvné hloubkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.3","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Posuvné hloubkoměry"},{"_id":"fa239a5eff67eea38fa8f797","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Głowice mikrometryczne","test_object_en":"Micrometer heads","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 25 mm","cmc":"1,0 µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"1,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 25 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.31","norm_bases":["IW5.8.31"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głowice mikrometryczne Wzorcowanie — Długość\n0 mm do 25 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.31 Glowice mikrometryczne Wzorcowanie — Dlugosc\n0 mm do 25 mm CMC 1,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.31","search_en":"Micrometer heads Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.31","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":21,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.31","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 25 mm","cmc":"1,0 µm"}],"reference_de":"Internes Verfahren IW5.8.31","regulatory_area_de":"Länge","search_de":"Mikrometerköpfe Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.31","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Mikrometerköpfe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"1,0 µm"}],"reference_zh":"内部程序 IW5.8.31","regulatory_area_zh":"长度","search_zh":"测微头 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.31","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"测微头","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 25 mm","cmc":"1,0 µm"}],"reference_cs":"Vnitřní postup IW5.8.31","regulatory_area_cs":"Délka","search_cs":"Mikrometrické hlavice Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.31","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometrické hlavice"},{"_id":"7c7386c8332ebeaed46888f9","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Grubościomierze czujnikowe o rozdzielczości 0,001 mm","test_object_en":"Dial thickness gauges with a resolution of 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"1,4 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"1,4 µm"}],"parameters_en":[{"name":"","range":"0 mm do 10 mm","cmc":"1,4 µm"},{"name":"","range":"0 mm to 50 mm","cmc":"1,4 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 1,4 µm\n0 mm do 50 mm CMC 1,4 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.10","norm_bases":["IW5.8.10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Grubościomierze czujnikowe o rozdzielczości 0,001 mm Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 1,4 µm\n0 mm do 50 mm CMC 1,4 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.10 Grubosciomierze czujnikowe o rozdzielczosci 0,001 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 10 mm CMC 1,4 µm\n0 mm do 50 mm CMC 1,4 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.10","search_en":"Dial thickness gauges with a resolution of 0,001 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":22,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.10","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 10 mm","cmc":"1,4 µm"},{"name":"","range":"0 mm bis 50 mm","cmc":"1,4 µm"}],"reference_de":"Internes Verfahren IW5.8.10","regulatory_area_de":"Länge","search_de":"Dickenmessgeräte mit Messuhr mit einer Auflösung von 0,001 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.10","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Dickenmessgeräte mit Messuhr mit einer Auflösung von 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 10 mm","cmc":"1,4 µm"},{"name":"","range":"0 mm 至 50 mm","cmc":"1,4 µm"}],"reference_zh":"内部程序 IW5.8.10","regulatory_area_zh":"长度","search_zh":"分辨力 0,001 mm 的指示式测厚仪 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.10","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"分辨力 0,001 mm 的指示式测厚仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 10 mm","cmc":"1,4 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"1,4 µm"}],"reference_cs":"Vnitřní postup IW5.8.10","regulatory_area_cs":"Délka","search_cs":"Tloušťkoměry s úchylkoměrem s rozlišením 0,001 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.10","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Tloušťkoměry s úchylkoměrem s rozlišením 0,001 mm"},{"_id":"e89fc314c7ce1e9496210f50","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Grubościomierze czujnikowe o rozdzielczości 0,01 mm","test_object_en":"Dial thickness gauges with a resolution of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"6 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 50 mm CMC 6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.10","norm_bases":["IW5.8.10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Grubościomierze czujnikowe o rozdzielczości 0,01 mm Wzorcowanie — Długość\n0 mm do 50 mm CMC 6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.10 Grubosciomierze czujnikowe o rozdzielczosci 0,01 mm Wzorcowanie — Dlugosc\n0 mm do 50 mm CMC 6 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.10","search_en":"Dial thickness gauges with a resolution of 0,01 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":23,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.10","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"6 µm"}],"reference_de":"Internes Verfahren IW5.8.10","regulatory_area_de":"Länge","search_de":"Dickenmessgeräte mit Messuhr mit einer Auflösung von 0,01 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.10","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Dickenmessgeräte mit Messuhr mit einer Auflösung von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"6 µm"}],"reference_zh":"内部程序 IW5.8.10","regulatory_area_zh":"长度","search_zh":"分辨力 0,01 mm 的指示式测厚仪 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.10","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"分辨力 0,01 mm 的指示式测厚仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"6 µm"}],"reference_cs":"Vnitřní postup IW5.8.10","regulatory_area_cs":"Délka","search_cs":"Tloušťkoměry s úchylkoměrem s rozlišením 0,01 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.10","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Tloušťkoměry s úchylkoměrem s rozlišením 0,01 mm"},{"_id":"8eef9f3276d6e3ae7373b8a2","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Grubościomierze czujnikowe o wartości działki elementarnej 0,01 mm","test_object_en":"Dial thickness gauges with a scale interval of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"1,4 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"1,4 µm"}],"parameters_en":[{"name":"","range":"0 mm do 10 mm","cmc":"1,4 µm"},{"name":"","range":"0 mm to 50 mm","cmc":"1,4 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 1,4 µm\n0 mm do 50 mm CMC 1,4 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.10","norm_bases":["IW5.8.10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Grubościomierze czujnikowe o wartości działki elementarnej 0,01 mm Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 1,4 µm\n0 mm do 50 mm CMC 1,4 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.10 Grubosciomierze czujnikowe o wartosci dzialki elementarnej 0,01 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 10 mm CMC 1,4 µm\n0 mm do 50 mm CMC 1,4 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.10","search_en":"Dial thickness gauges with a scale interval of 0,01 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":24,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.10","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 10 mm","cmc":"1,4 µm"},{"name":"","range":"0 mm bis 50 mm","cmc":"1,4 µm"}],"reference_de":"Internes Verfahren IW5.8.10","regulatory_area_de":"Länge","search_de":"Dickenmessgeräte mit Messuhr mit einem Skalenteilungswert von 0,01 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.10","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Dickenmessgeräte mit Messuhr mit einem Skalenteilungswert von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 10 mm","cmc":"1,4 µm"},{"name":"","range":"0 mm 至 50 mm","cmc":"1,4 µm"}],"reference_zh":"内部程序 IW5.8.10","regulatory_area_zh":"长度","search_zh":"分度值 0,01 mm 的指示式测厚仪 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.10","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"分度值 0,01 mm 的指示式测厚仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 10 mm","cmc":"1,4 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"1,4 µm"}],"reference_cs":"Vnitřní postup IW5.8.10","regulatory_area_cs":"Délka","search_cs":"Tloušťkoměry s úchylkoměrem s hodnotou dílku 0,01 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.10","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Tloušťkoměry s úchylkoměrem s hodnotou dílku 0,01 mm"},{"_id":"3792daf2dff96a3b7314cf39","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Grubościomierze czujnikowe o wartości działki elementarnej 0,1 mm","test_object_en":"Dial thickness gauges with a scale interval of 0,1 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"6 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 50 mm CMC 6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.10","norm_bases":["IW5.8.10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Grubościomierze czujnikowe o wartości działki elementarnej 0,1 mm Wzorcowanie — Długość\n0 mm do 50 mm CMC 6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.10 Grubosciomierze czujnikowe o wartosci dzialki elementarnej 0,1 mm Wzorcowanie — Dlugosc\n0 mm do 50 mm CMC 6 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.10","search_en":"Dial thickness gauges with a scale interval of 0,1 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":25,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.10","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"6 µm"}],"reference_de":"Internes Verfahren IW5.8.10","regulatory_area_de":"Länge","search_de":"Dickenmessgeräte mit Messuhr mit einem Skalenteilungswert von 0,1 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.10","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Dickenmessgeräte mit Messuhr mit einem Skalenteilungswert von 0,1 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"6 µm"}],"reference_zh":"内部程序 IW5.8.10","regulatory_area_zh":"长度","search_zh":"分度值 0,1 mm 的指示式测厚仪 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.10","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"分度值 0,1 mm 的指示式测厚仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"6 µm"}],"reference_cs":"Vnitřní postup IW5.8.10","regulatory_area_cs":"Délka","search_cs":"Tloušťkoměry s úchylkoměrem s hodnotou dílku 0,1 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.10","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Tloušťkoměry s úchylkoměrem s hodnotou dílku 0,1 mm"},{"_id":"3e2bc3cac0de4e4def40be6b","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Macki czujnikowe","test_object_en":"Dial calipers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- do pomiarów wewnętrznych","range":"2,5 mm do 12,5 mm","cmc":"1,1 µm"},{"name":"- do pomiarów wewnętrznych","range":"10 mm do 22 mm","cmc":"1,4 µm"},{"name":"- do pomiarów wewnętrznych","range":"10 mm do 35 mm","cmc":"1,6 µm"},{"name":"- do pomiarów wewnętrznych","range":"30 mm do 55 mm","cmc":"1,8 µm"},{"name":"- do pomiarów wewnętrznych","range":"40 mm do 90 mm","cmc":"2,8 µm"}],"parameters_en":[{"name":"- for internal measurements","range":"2,5 mm to 12,5 mm","cmc":"1,1 µm"},{"name":"- for internal measurements","range":"10 mm to 22 mm","cmc":"1,4 µm"},{"name":"- for internal measurements","range":"10 mm to 35 mm","cmc":"1,6 µm"},{"name":"- for internal measurements","range":"30 mm to 55 mm","cmc":"1,8 µm"},{"name":"- for internal measurements","range":"40 mm to 90 mm","cmc":"2,8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- do pomiarów wewnętrznych 2,5 mm do 12,5 mm CMC 1,1 µm\n- do pomiarów wewnętrznych 10 mm do 22 mm CMC 1,4 µm\n- do pomiarów wewnętrznych 10 mm do 35 mm CMC 1,6 µm\n- do pomiarów wewnętrznych 30 mm do 55 mm CMC 1,8 µm\n- do pomiarów wewnętrznych 40 mm do 90 mm CMC 2,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.22","norm_bases":["IW5.8.22"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Macki czujnikowe Wzorcowanie — Długość\nZakres:\n- do pomiarów wewnętrznych 2,5 mm do 12,5 mm CMC 1,1 µm\n- do pomiarów wewnętrznych 10 mm do 22 mm CMC 1,4 µm\n- do pomiarów wewnętrznych 10 mm do 35 mm CMC 1,6 µm\n- do pomiarów wewnętrznych 30 mm do 55 mm CMC 1,8 µm\n- do pomiarów wewnętrznych 40 mm do 90 mm CMC 2,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.22 Macki czujnikowe Wzorcowanie — Dlugosc\nZakres:\n- do pomiarow wewnetrznych 2,5 mm do 12,5 mm CMC 1,1 µm\n- do pomiarow wewnetrznych 10 mm do 22 mm CMC 1,4 µm\n- do pomiarow wewnetrznych 10 mm do 35 mm CMC 1,6 µm\n- do pomiarow wewnetrznych 30 mm do 55 mm CMC 1,8 µm\n- do pomiarow wewnetrznych 40 mm do 90 mm CMC 2,8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.22","search_en":"Dial calipers Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) - for internal measurements - for internal measurements - for internal measurements - for internal measurements - for internal measurements Internal procedure IW5.8.22","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":26,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.22","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- für Innenmessungen","range":"2,5 mm to 12,5 mm","cmc":"1,1 µm"},{"name":"- für Innenmessungen","range":"10 mm to 22 mm","cmc":"1,4 µm"},{"name":"- für Innenmessungen","range":"10 mm to 35 mm","cmc":"1,6 µm"},{"name":"- für Innenmessungen","range":"30 mm to 55 mm","cmc":"1,8 µm"},{"name":"- für Innenmessungen","range":"40 mm to 90 mm","cmc":"2,8 µm"}],"reference_de":"Internes Verfahren IW5.8.22","regulatory_area_de":"Länge","search_de":"Messuhr-Taster (Innen-/Außen) Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) - für Innenmessungen - für Innenmessungen - für Innenmessungen - für Innenmessungen - für Innenmessungen Internes Verfahren IW5.8.22","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Messuhr-Taster (Innen-/Außen)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 用于内尺寸测量","range":"2,5 mm to 12,5 mm","cmc":"1,1 µm"},{"name":"- 用于内尺寸测量","range":"10 mm to 22 mm","cmc":"1,4 µm"},{"name":"- 用于内尺寸测量","range":"10 mm to 35 mm","cmc":"1,6 µm"},{"name":"- 用于内尺寸测量","range":"30 mm to 55 mm","cmc":"1,8 µm"},{"name":"- 用于内尺寸测量","range":"40 mm to 90 mm","cmc":"2,8 µm"}],"reference_zh":"内部程序 IW5.8.22","regulatory_area_zh":"长度","search_zh":"指示表式卡规 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) - 用于内尺寸测量 - 用于内尺寸测量 - 用于内尺寸测量 - 用于内尺寸测量 - 用于内尺寸测量 内部程序 IW5.8.22","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"指示表式卡规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- pro vnitřní měření","range":"2,5 mm to 12,5 mm","cmc":"1,1 µm"},{"name":"- pro vnitřní měření","range":"10 mm to 22 mm","cmc":"1,4 µm"},{"name":"- pro vnitřní měření","range":"10 mm to 35 mm","cmc":"1,6 µm"},{"name":"- pro vnitřní měření","range":"30 mm to 55 mm","cmc":"1,8 µm"},{"name":"- pro vnitřní měření","range":"40 mm to 90 mm","cmc":"2,8 µm"}],"reference_cs":"Vnitřní postup IW5.8.22","regulatory_area_cs":"Délka","search_cs":"Úchylkoměrné dutinoměry a třmeny Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) - pro vnitřní měření - pro vnitřní měření - pro vnitřní měření - pro vnitřní měření - pro vnitřní měření Vnitřní postup IW5.8.22","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Úchylkoměrné dutinoměry a třmeny"},{"_id":"f248686475e7b0cc17a2f372","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Macki czujnikowe","test_object_en":"Dial calipers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- do pomiarów zewnętrznych","range":"0 mm do 20 mm","cmc":"1,0 µm"},{"name":"- do pomiarów zewnętrznych","range":"20 mm do 40 mm","cmc":"1,3 µm"},{"name":"- do pomiarów zewnętrznych","range":"40 mm do 60 mm","cmc":"1,8 µm"},{"name":"- do pomiarów zewnętrznych","range":"60 mm do 80 mm","cmc":"2,3 µm"},{"name":"- do pomiarów zewnętrznych","range":"80 mm do 100 mm","cmc":"2,8 µm"}],"parameters_en":[{"name":"- for external measurements","range":"0 mm to 20 mm","cmc":"1,0 µm"},{"name":"- for external measurements","range":"20 mm to 40 mm","cmc":"1,3 µm"},{"name":"- for external measurements","range":"40 mm to 60 mm","cmc":"1,8 µm"},{"name":"- for external measurements","range":"60 mm to 80 mm","cmc":"2,3 µm"},{"name":"- for external measurements","range":"80 mm to 100 mm","cmc":"2,8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- do pomiarów zewnętrznych 0 mm do 20 mm CMC 1,0 µm\n- do pomiarów zewnętrznych 20 mm do 40 mm CMC 1,3 µm\n- do pomiarów zewnętrznych 40 mm do 60 mm CMC 1,8 µm\n- do pomiarów zewnętrznych 60 mm do 80 mm CMC 2,3 µm\n- do pomiarów zewnętrznych 80 mm do 100 mm CMC 2,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.22","norm_bases":["IW5.8.22"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Macki czujnikowe Wzorcowanie — Długość\nZakres:\n- do pomiarów zewnętrznych 0 mm do 20 mm CMC 1,0 µm\n- do pomiarów zewnętrznych 20 mm do 40 mm CMC 1,3 µm\n- do pomiarów zewnętrznych 40 mm do 60 mm CMC 1,8 µm\n- do pomiarów zewnętrznych 60 mm do 80 mm CMC 2,3 µm\n- do pomiarów zewnętrznych 80 mm do 100 mm CMC 2,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.22 Macki czujnikowe Wzorcowanie — Dlugosc\nZakres:\n- do pomiarow zewnetrznych 0 mm do 20 mm CMC 1,0 µm\n- do pomiarow zewnetrznych 20 mm do 40 mm CMC 1,3 µm\n- do pomiarow zewnetrznych 40 mm do 60 mm CMC 1,8 µm\n- do pomiarow zewnetrznych 60 mm do 80 mm CMC 2,3 µm\n- do pomiarow zewnetrznych 80 mm do 100 mm CMC 2,8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.22","search_en":"Dial calipers Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) - for external measurements - for external measurements - for external measurements - for external measurements - for external measurements Internal procedure IW5.8.22","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":27,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.22","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- für Außenmessungen","range":"0 mm to 20 mm","cmc":"1,0 µm"},{"name":"- für Außenmessungen","range":"20 mm to 40 mm","cmc":"1,3 µm"},{"name":"- für Außenmessungen","range":"40 mm to 60 mm","cmc":"1,8 µm"},{"name":"- für Außenmessungen","range":"60 mm to 80 mm","cmc":"2,3 µm"},{"name":"- für Außenmessungen","range":"80 mm to 100 mm","cmc":"2,8 µm"}],"reference_de":"Internes Verfahren IW5.8.22","regulatory_area_de":"Länge","search_de":"Messuhr-Taster (Innen-/Außen) Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) - für Außenmessungen - für Außenmessungen - für Außenmessungen - für Außenmessungen - für Außenmessungen Internes Verfahren IW5.8.22","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Messuhr-Taster (Innen-/Außen)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 用于外尺寸测量","range":"0 mm to 20 mm","cmc":"1,0 µm"},{"name":"- 用于外尺寸测量","range":"20 mm to 40 mm","cmc":"1,3 µm"},{"name":"- 用于外尺寸测量","range":"40 mm to 60 mm","cmc":"1,8 µm"},{"name":"- 用于外尺寸测量","range":"60 mm to 80 mm","cmc":"2,3 µm"},{"name":"- 用于外尺寸测量","range":"80 mm to 100 mm","cmc":"2,8 µm"}],"reference_zh":"内部程序 IW5.8.22","regulatory_area_zh":"长度","search_zh":"指示表式卡规 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) - 用于外尺寸测量 - 用于外尺寸测量 - 用于外尺寸测量 - 用于外尺寸测量 - 用于外尺寸测量 内部程序 IW5.8.22","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"指示表式卡规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- pro vnější měření","range":"0 mm to 20 mm","cmc":"1,0 µm"},{"name":"- pro vnější měření","range":"20 mm to 40 mm","cmc":"1,3 µm"},{"name":"- pro vnější měření","range":"40 mm to 60 mm","cmc":"1,8 µm"},{"name":"- pro vnější měření","range":"60 mm to 80 mm","cmc":"2,3 µm"},{"name":"- pro vnější měření","range":"80 mm to 100 mm","cmc":"2,8 µm"}],"reference_cs":"Vnitřní postup IW5.8.22","regulatory_area_cs":"Délka","search_cs":"Úchylkoměrné dutinoměry a třmeny Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) - pro vnější měření - pro vnější měření - pro vnější měření - pro vnější měření - pro vnější měření Vnitřní postup IW5.8.22","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Úchylkoměrné dutinoměry a třmeny"},{"_id":"4cbaf2caedc86dd2fcd7ac8f","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Mierniki do pomiaru grubości powłok","test_object_en":"Coating thickness gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 µm do 1000 µm","cmc":"3,3 µm"},{"name":"","range":"1000 µm do 2000 µm","cmc":"5,6 µm"},{"name":"","range":"2000 µm do 3000 µm","cmc":"8,3 µm"},{"name":"","range":"3000 µm do 4000 µm","cmc":"10,5 µm"},{"name":"","range":"4000 µm do 5150 µm","cmc":"14,0 µm"}],"parameters_en":[{"name":"","range":"0 µm to 1000 µm","cmc":"3,3 µm"},{"name":"","range":"1000 µm to 2000 µm","cmc":"5,6 µm"},{"name":"","range":"2000 µm to 3000 µm","cmc":"8,3 µm"},{"name":"","range":"3000 µm to 4000 µm","cmc":"10,5 µm"},{"name":"","range":"4000 µm to 5150 µm","cmc":"14,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem folii wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using reference foils; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem folii wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using reference foils","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 µm do 1000 µm CMC 3,3 µm\n1000 µm do 2000 µm CMC 5,6 µm\n2000 µm do 3000 µm CMC 8,3 µm\n3000 µm do 4000 µm CMC 10,5 µm\n4000 µm do 5150 µm CMC 14,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem folii wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.43","norm_bases":["IW5.8.43"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki do pomiaru grubości powłok Wzorcowanie — Długość\nZakres:\n0 µm do 1000 µm CMC 3,3 µm\n1000 µm do 2000 µm CMC 5,6 µm\n2000 µm do 3000 µm CMC 8,3 µm\n3000 µm do 4000 µm CMC 10,5 µm\n4000 µm do 5150 µm CMC 14,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem folii wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.43 Mierniki do pomiaru grubosci powlok Wzorcowanie — Dlugosc\nZakres:\n0 µm do 1000 µm CMC 3,3 µm\n1000 µm do 2000 µm CMC 5,6 µm\n2000 µm do 3000 µm CMC 8,3 µm\n3000 µm do 4000 µm CMC 10,5 µm\n4000 µm do 5150 µm CMC 14,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem folii wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.43","search_en":"Coating thickness gauges Calibration — Length Internal procedure; Direct method using reference foils; At permanent location (S) Length Internal procedure Direct method using reference foils At permanent location (S) Internal procedure IW5.8.43","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":28,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.43","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 µm to 1000 µm","cmc":"3,3 µm"},{"name":"","range":"1000 µm to 2000 µm","cmc":"5,6 µm"},{"name":"","range":"2000 µm to 3000 µm","cmc":"8,3 µm"},{"name":"","range":"3000 µm to 4000 µm","cmc":"10,5 µm"},{"name":"","range":"4000 µm to 5150 µm","cmc":"14,0 µm"}],"reference_de":"Internes Verfahren IW5.8.43","regulatory_area_de":"Länge","search_de":"Schichtdickenmessgeräte Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Referenzfolien; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Referenzfolien Am festen Standort (S) Internes Verfahren IW5.8.43","technique_de":"Internes Verfahren; Direktes Verfahren mit Referenzfolien; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Referenzfolien","Am festen Standort (S)"],"test_object_de":"Schichtdickenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 µm to 1000 µm","cmc":"3,3 µm"},{"name":"","range":"1000 µm to 2000 µm","cmc":"5,6 µm"},{"name":"","range":"2000 µm to 3000 µm","cmc":"8,3 µm"},{"name":"","range":"3000 µm to 4000 µm","cmc":"10,5 µm"},{"name":"","range":"4000 µm to 5150 µm","cmc":"14,0 µm"}],"reference_zh":"内部程序 IW5.8.43","regulatory_area_zh":"长度","search_zh":"涂层测厚仪 校准 — 长度 内部程序；使用标准箔片的直接法；在固定地点 (S) 长度 内部程序 使用标准箔片的直接法 在固定地点 (S) 内部程序 IW5.8.43","technique_zh":"内部程序；使用标准箔片的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用标准箔片的直接法","在固定地点 (S)"],"test_object_zh":"涂层测厚仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 µm to 1000 µm","cmc":"3,3 µm"},{"name":"","range":"1000 µm to 2000 µm","cmc":"5,6 µm"},{"name":"","range":"2000 µm to 3000 µm","cmc":"8,3 µm"},{"name":"","range":"3000 µm to 4000 µm","cmc":"10,5 µm"},{"name":"","range":"4000 µm to 5150 µm","cmc":"14,0 µm"}],"reference_cs":"Vnitřní postup IW5.8.43","regulatory_area_cs":"Délka","search_cs":"Měřidla tloušťky povlaků Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím etalonových fólií; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím etalonových fólií Ve stálé lokalitě (S) Vnitřní postup IW5.8.43","technique_cs":"Vnitřní postup; Přímá metoda s použitím etalonových fólií; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím etalonových fólií","Ve stálé lokalitě (S)"],"test_object_cs":"Měřidla tloušťky povlaků"},{"_id":"0e193fd744c171972bf7858e","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Mikrometry wewnętrzne","test_object_en":"Internal micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"5 mm do 30 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"2,9 µm"}],"parameters_en":[{"name":"","range":"5 mm do 30 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm to 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm to 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"2,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n5 mm do 30 mm CMC 1,1 µm\n25 mm do 50 mm CMC 1,6 µm\n50 mm do 75 mm CMC 2,2 µm\n75 mm do 100 mm CMC 2,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.23","norm_bases":["IW5.8.23"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mikrometry wewnętrzne Wzorcowanie — Długość\nZakres:\n5 mm do 30 mm CMC 1,1 µm\n25 mm do 50 mm CMC 1,6 µm\n50 mm do 75 mm CMC 2,2 µm\n75 mm do 100 mm CMC 2,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.23 Mikrometry wewnetrzne Wzorcowanie — Dlugosc\nZakres:\n5 mm do 30 mm CMC 1,1 µm\n25 mm do 50 mm CMC 1,6 µm\n50 mm do 75 mm CMC 2,2 µm\n75 mm do 100 mm CMC 2,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.23","search_en":"Internal micrometers Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.23","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":29,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.23","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"5 mm do 30 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm bis 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm bis 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"2,9 µm"}],"reference_de":"Internes Verfahren IW5.8.23","regulatory_area_de":"Länge","search_de":"Innenmessschrauben Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.23","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Innenmessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"5 mm do 30 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm 至 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm 至 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"2,9 µm"}],"reference_zh":"内部程序 IW5.8.23","regulatory_area_zh":"长度","search_zh":"内径千分尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.23","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"内径千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"5 mm do 30 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"2,9 µm"}],"reference_cs":"Vnitřní postup IW5.8.23","regulatory_area_cs":"Délka","search_cs":"Vnitřní mikrometry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.23","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Vnitřní mikrometry"},{"_id":"3b39c859b7443a9f649396e1","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Mikrometry zewnętrzne","test_object_en":"External micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,5 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"2,8 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"3,7 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"4,3 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"4,9 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"5,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,2 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"6,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,1 µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm to 50 mm","cmc":"1,5 µm"},{"name":"","range":"50 mm to 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"2,8 µm"},{"name":"","range":"100 mm to 125 mm","cmc":"3,7 µm"},{"name":"","range":"125 mm to 150 mm","cmc":"4,3 µm"},{"name":"","range":"150 mm to 175 mm","cmc":"4,9 µm"},{"name":"","range":"175 mm to 200 mm","cmc":"5,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,2 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"6,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,1 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 1,0 µm\n25 mm do 50 mm CMC 1,5 µm\n50 mm do 75 mm CMC 2,2 µm\n75 mm do 100 mm CMC 2,8 µm\n100 mm do 125 mm CMC 3,7 µm\n125 mm do 150 mm CMC 4,3 µm\n150 mm do 175 mm CMC 4,9 µm\n175 mm do 200 mm CMC 5,5 µm\n200 mm do 225 mm CMC 6,2 µm\n225 mm do 250 mm CMC 6,8 µm\n250 mm do 275 mm CMC 7,5 µm\n275 mm do 300 mm CMC 8,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.4","norm_bases":["IW5.8.4"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mikrometry zewnętrzne Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 1,0 µm\n25 mm do 50 mm CMC 1,5 µm\n50 mm do 75 mm CMC 2,2 µm\n75 mm do 100 mm CMC 2,8 µm\n100 mm do 125 mm CMC 3,7 µm\n125 mm do 150 mm CMC 4,3 µm\n150 mm do 175 mm CMC 4,9 µm\n175 mm do 200 mm CMC 5,5 µm\n200 mm do 225 mm CMC 6,2 µm\n225 mm do 250 mm CMC 6,8 µm\n250 mm do 275 mm CMC 7,5 µm\n275 mm do 300 mm CMC 8,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.4 Mikrometry zewnetrzne Wzorcowanie — Dlugosc\nZakres:\n0 mm do 25 mm CMC 1,0 µm\n25 mm do 50 mm CMC 1,5 µm\n50 mm do 75 mm CMC 2,2 µm\n75 mm do 100 mm CMC 2,8 µm\n100 mm do 125 mm CMC 3,7 µm\n125 mm do 150 mm CMC 4,3 µm\n150 mm do 175 mm CMC 4,9 µm\n175 mm do 200 mm CMC 5,5 µm\n200 mm do 225 mm CMC 6,2 µm\n225 mm do 250 mm CMC 6,8 µm\n250 mm do 275 mm CMC 7,5 µm\n275 mm do 300 mm CMC 8,1 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.4","search_en":"External micrometers Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.4","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":30,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.4","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm bis 50 mm","cmc":"1,5 µm"},{"name":"","range":"50 mm bis 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"2,8 µm"},{"name":"","range":"100 mm bis 125 mm","cmc":"3,7 µm"},{"name":"","range":"125 mm bis 150 mm","cmc":"4,3 µm"},{"name":"","range":"150 mm bis 175 mm","cmc":"4,9 µm"},{"name":"","range":"175 mm bis 200 mm","cmc":"5,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,2 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"6,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,1 µm"}],"reference_de":"Internes Verfahren IW5.8.4","regulatory_area_de":"Länge","search_de":"Bügelmessschrauben Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.4","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Bügelmessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm 至 50 mm","cmc":"1,5 µm"},{"name":"","range":"50 mm 至 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"2,8 µm"},{"name":"","range":"100 mm 至 125 mm","cmc":"3,7 µm"},{"name":"","range":"125 mm 至 150 mm","cmc":"4,3 µm"},{"name":"","range":"150 mm 至 175 mm","cmc":"4,9 µm"},{"name":"","range":"175 mm 至 200 mm","cmc":"5,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,2 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"6,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,1 µm"}],"reference_zh":"内部程序 IW5.8.4","regulatory_area_zh":"长度","search_zh":"外径千分尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.4","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"外径千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,5 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"2,2 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"2,8 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"3,7 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"4,3 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"4,9 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"5,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,2 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"6,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,1 µm"}],"reference_cs":"Vnitřní postup IW5.8.4","regulatory_area_cs":"Délka","search_cs":"Mikrometry pro vnější měření Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.4","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometry pro vnější měření"},{"_id":"e98cb6ce4703d2f77c02d26f","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Mikrometry z wbudowanym czujnikiem","test_object_en":"Indicating micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- układ czujnikowy","range":"od -140 µm do +140 µm","cmc":"1,0 µm"},{"name":"- układ mikrometryczny","range":"0 mm do 25 mm","cmc":"1,2 µm"},{"name":"- układ mikrometryczny","range":"0 mm do 50 mm","cmc":"1,5 µm"}],"parameters_en":[{"name":"- indicator system","range":"from -140 µm to +140 µm","cmc":"1,0 µm"},{"name":"- micrometer system","range":"0 mm to 25 mm","cmc":"1,2 µm"},{"name":"- micrometer system","range":"0 mm to 50 mm","cmc":"1,5 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- układ czujnikowy od -140 µm do +140 µm CMC 1,0 µm\n- układ mikrometryczny 0 mm do 25 mm CMC 1,2 µm\n- układ mikrometryczny 0 mm do 50 mm CMC 1,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.18","norm_bases":["IW5.8.18"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mikrometry z wbudowanym czujnikiem Wzorcowanie — Długość\nZakres:\n- układ czujnikowy od -140 µm do +140 µm CMC 1,0 µm\n- układ mikrometryczny 0 mm do 25 mm CMC 1,2 µm\n- układ mikrometryczny 0 mm do 50 mm CMC 1,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.18 Mikrometry z wbudowanym czujnikiem Wzorcowanie — Dlugosc\nZakres:\n- uklad czujnikowy od -140 µm do +140 µm CMC 1,0 µm\n- uklad mikrometryczny 0 mm do 25 mm CMC 1,2 µm\n- uklad mikrometryczny 0 mm do 50 mm CMC 1,5 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.18","search_en":"Indicating micrometers Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) - indicator system - micrometer system - micrometer system Internal procedure IW5.8.18","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":31,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.18","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Messuhrsystem","range":"from -140 µm to +140 µm","cmc":"1,0 µm"},{"name":"- Mikrometersystem","range":"0 mm bis 25 mm","cmc":"1,2 µm"},{"name":"- Mikrometersystem","range":"0 mm bis 50 mm","cmc":"1,5 µm"}],"reference_de":"Internes Verfahren IW5.8.18","regulatory_area_de":"Länge","search_de":"Feinzeigermessschrauben Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) - Messuhrsystem - Mikrometersystem - Mikrometersystem Internes Verfahren IW5.8.18","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Feinzeigermessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 指示表系统","range":"from -140 µm to +140 µm","cmc":"1,0 µm"},{"name":"- 千分尺系统","range":"0 mm 至 25 mm","cmc":"1,2 µm"},{"name":"- 千分尺系统","range":"0 mm 至 50 mm","cmc":"1,5 µm"}],"reference_zh":"内部程序 IW5.8.18","regulatory_area_zh":"长度","search_zh":"带表千分尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) - 指示表系统 - 千分尺系统 - 千分尺系统 内部程序 IW5.8.18","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"带表千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- úchylkoměrový systém","range":"from -140 µm to +140 µm","cmc":"1,0 µm"},{"name":"- mikrometrický systém","range":"0 mm do 25 mm","cmc":"1,2 µm"},{"name":"- mikrometrický systém","range":"0 mm do 50 mm","cmc":"1,5 µm"}],"reference_cs":"Vnitřní postup IW5.8.18","regulatory_area_cs":"Délka","search_cs":"Mikrometry s vestavěným úchylkoměrem Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) - úchylkoměrový systém - mikrometrický systém - mikrometrický systém Vnitřní postup IW5.8.18","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometry s vestavěným úchylkoměrem"},{"_id":"b1eeb1c553427f98f6b163b0","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Pierścienie wzorcowe","test_object_en":"Setting rings","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"2 mm do 30 mm","cmc":"1,8 µm"}],"parameters_en":[{"name":"","range":"2 mm to 30 mm","cmc":"1,8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n2 mm do 30 mm CMC 1,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.44 w oparciu o EURAMET cg-6 Version 2.0 (03/2011)","norm_bases":["IW5.8.44","EURAMET cg-6 Version 2.0 (03/2011)"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Pierścienie wzorcowe Wzorcowanie — Długość\n2 mm do 30 mm CMC 1,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.44 w oparciu o EURAMET cg-6 Version 2.0 (03/2011) Pierscienie wzorcowe Wzorcowanie — Dlugosc\n2 mm do 30 mm CMC 1,8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500 wyposazonego w czujnik elektroniczny; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.44 w oparciu o EURAMET cg-6 Version 2.0 (03/2011)","search_en":"Setting rings Calibration — Length Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe; At permanent location (S) Length Internal procedure Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe At permanent location (S) Internal procedure IW5.8.44 based on EURAMET cg-6 Version 2.0 (03/2011)","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":32,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.44 based on EURAMET cg-6 Version 2.0 (03/2011)","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"2 mm to 30 mm","cmc":"1,8 µm"}],"reference_de":"Internes Verfahren IW5.8.44 auf Grundlage von EURAMET cg-6 Version 2.0 (03/2011)","regulatory_area_de":"Länge","search_de":"Normalringe Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster Am festen Standort (S) Internes Verfahren IW5.8.44 auf Grundlage von EURAMET cg-6 Version 2.0 (03/2011)","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster","Am festen Standort (S)"],"test_object_de":"Normalringe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"2 mm to 30 mm","cmc":"1,8 µm"}],"reference_zh":"内部程序 IW5.8.44 依据EURAMET cg-6 Version 2.0 (03/2011)","regulatory_area_zh":"长度","search_zh":"标准环规 校准 — 长度 内部程序；使用配电子测头的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S) 长度 内部程序 使用配电子测头的Trimos Labconcept Premium 500测长仪的直接法 在固定地点 (S) 内部程序 IW5.8.44 依据EURAMET cg-6 Version 2.0 (03/2011)","technique_zh":"内部程序；使用配电子测头的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用配电子测头的Trimos Labconcept Premium 500测长仪的直接法","在固定地点 (S)"],"test_object_zh":"标准环规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"2 mm to 30 mm","cmc":"1,8 µm"}],"reference_cs":"Vnitřní postup IW5.8.44 na základě EURAMET cg-6 Version 2.0 (03/2011)","regulatory_area_cs":"Délka","search_cs":"Etalonové kroužky Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem Ve stálé lokalitě (S) Vnitřní postup IW5.8.44 na základě EURAMET cg-6 Version 2.0 (03/2011)","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem","Ve stálé lokalitě (S)"],"test_object_cs":"Etalonové kroužky"},{"_id":"0bd9448f858252df4ed362c7","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Pierścienie wzorcowe","test_object_en":"Setting rings","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"10 mm do 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm do 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm do 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm do 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm do 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm do 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm do 260 mm","cmc":"2,9 µm"},{"name":"","range":"260 mm do 300 mm","cmc":"3,2 µm"}],"parameters_en":[{"name":"","range":"10 mm to 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm to 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm to 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm to 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm to 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm to 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm to 260 mm","cmc":"2,9 µm"},{"name":"","range":"260 mm to 300 mm","cmc":"3,2 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n10 mm do 50 mm CMC 1,4 µm\n50 mm do 80 mm CMC 1,5 µm\n80 mm do 110 mm CMC 1,7 µm\n110 mm do 150 mm CMC 1,9 µm\n150 mm do 190 mm CMC 2,2 µm\n190 mm do 225 mm CMC 2,4 µm\n225 mm do 260 mm CMC 2,9 µm\n260 mm do 300 mm CMC 3,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.6 w oparciu o EURAMET cg-6 Version 2.0 (03/2011)","norm_bases":["IW5.8.6","EURAMET cg-6 Version 2.0 (03/2011)"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Pierścienie wzorcowe Wzorcowanie — Długość\nZakres:\n10 mm do 50 mm CMC 1,4 µm\n50 mm do 80 mm CMC 1,5 µm\n80 mm do 110 mm CMC 1,7 µm\n110 mm do 150 mm CMC 1,9 µm\n150 mm do 190 mm CMC 2,2 µm\n190 mm do 225 mm CMC 2,4 µm\n225 mm do 260 mm CMC 2,9 µm\n260 mm do 300 mm CMC 3,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.6 w oparciu o EURAMET cg-6 Version 2.0 (03/2011) Pierscienie wzorcowe Wzorcowanie — Dlugosc\nZakres:\n10 mm do 50 mm CMC 1,4 µm\n50 mm do 80 mm CMC 1,5 µm\n80 mm do 110 mm CMC 1,7 µm\n110 mm do 150 mm CMC 1,9 µm\n150 mm do 190 mm CMC 2,2 µm\n190 mm do 225 mm CMC 2,4 µm\n225 mm do 260 mm CMC 2,9 µm\n260 mm do 300 mm CMC 3,2 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500 wyposazonego w kablaki; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.6 w oparciu o EURAMET cg-6 Version 2.0 (03/2011)","search_en":"Setting rings Calibration — Length Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms; At permanent location (S) Length Internal procedure Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms At permanent location (S) Internal procedure IW5.8.6 based on EURAMET cg-6 Version 2.0 (03/2011)","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":33,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.6 based on EURAMET cg-6 Version 2.0 (03/2011)","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"10 mm to 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm to 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm to 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm to 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm to 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm to 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm to 260 mm","cmc":"2,9 µm"},{"name":"","range":"260 mm to 300 mm","cmc":"3,2 µm"}],"reference_de":"Internes Verfahren IW5.8.6 auf Grundlage von EURAMET cg-6 Version 2.0 (03/2011)","regulatory_area_de":"Länge","search_de":"Normalringe Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln Am festen Standort (S) Internes Verfahren IW5.8.6 auf Grundlage von EURAMET cg-6 Version 2.0 (03/2011)","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln","Am festen Standort (S)"],"test_object_de":"Normalringe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"10 mm to 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm to 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm to 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm to 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm to 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm to 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm to 260 mm","cmc":"2,9 µm"},{"name":"","range":"260 mm to 300 mm","cmc":"3,2 µm"}],"reference_zh":"内部程序 IW5.8.6 依据EURAMET cg-6 Version 2.0 (03/2011)","regulatory_area_zh":"长度","search_zh":"标准环规 校准 — 长度 内部程序；使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S) 长度 内部程序 使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法 在固定地点 (S) 内部程序 IW5.8.6 依据EURAMET cg-6 Version 2.0 (03/2011)","technique_zh":"内部程序；使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法","在固定地点 (S)"],"test_object_zh":"标准环规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"10 mm to 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm to 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm to 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm to 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm to 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm to 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm to 260 mm","cmc":"2,9 µm"},{"name":"","range":"260 mm to 300 mm","cmc":"3,2 µm"}],"reference_cs":"Vnitřní postup IW5.8.6 na základě EURAMET cg-6 Version 2.0 (03/2011)","regulatory_area_cs":"Délka","search_cs":"Etalonové kroužky Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny Ve stálé lokalitě (S) Vnitřní postup IW5.8.6 na základě EURAMET cg-6 Version 2.0 (03/2011)","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny","Ve stálé lokalitě (S)"],"test_object_cs":"Etalonové kroužky"},{"_id":"a202c7117ea3cdd41987c7df","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Płytki wzorcowe (klasy 0, 1 ,2)","test_object_en":"Gauge blocks (classes 0, 1 ,2)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,5 mm do 100 mm","cmc":"Q[0,073; 0,86⋅L] µm"}],"parameters_en":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,073; 0,86⋅L] µm"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,5 mm do 100 mm CMC Q[0,073; 0,86⋅L] µm\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.13 w oparciu o PN-EN ISO 3650:2000","norm_bases":["IW5.8.13","PN-EN ISO 3650:2000"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L – wielkość mierzona (m)","note_en":"L – measured quantity (m)","search_text":"Płytki wzorcowe (klasy 0, 1 ,2) Wzorcowanie — Długość\n0,5 mm do 100 mm CMC Q[0,073; 0,86⋅L] µm\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.13 w oparciu o PN-EN ISO 3650:2000 Plytki wzorcowe (klasy 0, 1 ,2) Wzorcowanie — Dlugosc\n0,5 mm do 100 mm CMC Q[0,073; 0,86⋅L] µm\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.13 w oparciu o PN-EN ISO 3650:2000","search_en":"Gauge blocks (classes 0, 1 ,2) Calibration — Length Internal procedure; At permanent location (S) Length Internal procedure At permanent location (S) Internal procedure IW5.8.13 based on PN-EN ISO 3650:2000","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":34,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.13 based on PN-EN ISO 3650:2000","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,073; 0,86⋅L] µm"}],"reference_de":"Internes Verfahren IW5.8.13 auf Grundlage von PN-EN ISO 3650:2000","regulatory_area_de":"Länge","search_de":"Parallelendmaße (Klassen 0, 1 ,2) Kalibrierung — Länge Internes Verfahren; Am festen Standort (S) Länge Internes Verfahren Am festen Standort (S) Internes Verfahren IW5.8.13 auf Grundlage von PN-EN ISO 3650:2000","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Parallelendmaße (Klassen 0, 1 ,2)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,073; 0,86⋅L] µm"}],"reference_zh":"内部程序 IW5.8.13 依据PN-EN ISO 3650:2000","regulatory_area_zh":"长度","search_zh":"量块（0、1、2级） 校准 — 长度 内部程序；在固定地点 (S) 长度 内部程序 在固定地点 (S) 内部程序 IW5.8.13 依据PN-EN ISO 3650:2000","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"量块（0、1、2级）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,073; 0,86⋅L] µm"}],"reference_cs":"Vnitřní postup IW5.8.13 na základě PN-EN ISO 3650:2000","regulatory_area_cs":"Délka","search_cs":"Koncové měrky (třídy 0, 1 ,2) Kalibrace — Délka Vnitřní postup; Ve stálé lokalitě (S) Délka Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup IW5.8.13 na základě PN-EN ISO 3650:2000","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky (třídy 0, 1 ,2)"},{"_id":"583a12b6a1ff7f1424c69c7a","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Płytki wzorcowe (klasy 0, 1 ,2)","test_object_en":"Gauge blocks (classes 0, 1 ,2)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,1 mm do 100 mm","cmc":"Q[0,095; 0,9⋅L] µm"}],"parameters_en":[{"name":"","range":"0,1 mm to 100 mm","cmc":"Q[0,095; 0,9⋅L] µm"}],"technique":"Procedura wewnętrzna; Metoda różnicowa z zastosowaniem komparatora dwuczujnikowego Mitutoyo GBCD-250; W stałej lokalizacji (S)","technique_en":"Internal procedure; Differential method using the Mitutoyo GBCD-250 two-probe comparator; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda różnicowa z zastosowaniem komparatora dwuczujnikowego Mitutoyo GBCD-250","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Differential method using the Mitutoyo GBCD-250 two-probe comparator","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,1 mm do 100 mm CMC Q[0,095; 0,9⋅L] µm\nProcedura wewnętrzna; Metoda różnicowa z zastosowaniem komparatora dwuczujnikowego Mitutoyo GBCD-250; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.13","norm_bases":["IW5.8.13"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L – wielkość mierzona (m)","note_en":"L – measured quantity (m)","search_text":"Płytki wzorcowe (klasy 0, 1 ,2) Wzorcowanie — Długość\n0,1 mm do 100 mm CMC Q[0,095; 0,9⋅L] µm\nProcedura wewnętrzna; Metoda różnicowa z zastosowaniem komparatora dwuczujnikowego Mitutoyo GBCD-250; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.13 Plytki wzorcowe (klasy 0, 1 ,2) Wzorcowanie — Dlugosc\n0,1 mm do 100 mm CMC Q[0,095; 0,9⋅L] µm\nProcedura wewnetrzna; Metoda roznicowa z zastosowaniem komparatora dwuczujnikowego Mitutoyo GBCD-250; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.13","search_en":"Gauge blocks (classes 0, 1 ,2) Calibration — Length Internal procedure; Differential method using the Mitutoyo GBCD-250 two-probe comparator; At permanent location (S) Length Internal procedure Differential method using the Mitutoyo GBCD-250 two-probe comparator At permanent location (S) Internal procedure IW5.8.13","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":35,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.13","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,1 mm to 100 mm","cmc":"Q[0,095; 0,9⋅L] µm"}],"reference_de":"Internes Verfahren IW5.8.13","regulatory_area_de":"Länge","search_de":"Parallelendmaße (Klassen 0, 1 ,2) Kalibrierung — Länge Internes Verfahren; Differenzverfahren mit dem Zweitaster-Komparator Mitutoyo GBCD-250; Am festen Standort (S) Länge Internes Verfahren Differenzverfahren mit dem Zweitaster-Komparator Mitutoyo GBCD-250 Am festen Standort (S) Internes Verfahren IW5.8.13","technique_de":"Internes Verfahren; Differenzverfahren mit dem Zweitaster-Komparator Mitutoyo GBCD-250; Am festen Standort (S)","techniques_de":["Internes Verfahren","Differenzverfahren mit dem Zweitaster-Komparator Mitutoyo GBCD-250","Am festen Standort (S)"],"test_object_de":"Parallelendmaße (Klassen 0, 1 ,2)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,1 mm to 100 mm","cmc":"Q[0,095; 0,9⋅L] µm"}],"reference_zh":"内部程序 IW5.8.13","regulatory_area_zh":"长度","search_zh":"量块（0、1、2级） 校准 — 长度 内部程序；使用Mitutoyo GBCD-250双测头比较仪的差值法；在固定地点 (S) 长度 内部程序 使用Mitutoyo GBCD-250双测头比较仪的差值法 在固定地点 (S) 内部程序 IW5.8.13","technique_zh":"内部程序；使用Mitutoyo GBCD-250双测头比较仪的差值法；在固定地点 (S)","techniques_zh":["内部程序","使用Mitutoyo GBCD-250双测头比较仪的差值法","在固定地点 (S)"],"test_object_zh":"量块（0、1、2级）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,1 mm to 100 mm","cmc":"Q[0,095; 0,9⋅L] µm"}],"reference_cs":"Vnitřní postup IW5.8.13","regulatory_area_cs":"Délka","search_cs":"Koncové měrky (třídy 0, 1 ,2) Kalibrace — Délka Vnitřní postup; Diferenční metoda s použitím dvousnímačového komparátoru Mitutoyo GBCD-250; Ve stálé lokalitě (S) Délka Vnitřní postup Diferenční metoda s použitím dvousnímačového komparátoru Mitutoyo GBCD-250 Ve stálé lokalitě (S) Vnitřní postup IW5.8.13","technique_cs":"Vnitřní postup; Diferenční metoda s použitím dvousnímačového komparátoru Mitutoyo GBCD-250; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Diferenční metoda s použitím dvousnímačového komparátoru Mitutoyo GBCD-250","Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky (třídy 0, 1 ,2)"},{"_id":"5c198008da7b731676b99479","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Przymiary półsztywne\nPrzymiary sztywne","test_object_en":"Semi-rigid rules\nRigid rules","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 1000 mm","cmc":"0,12 mm"},{"name":"","range":"1000 mm do 3000 mm","cmc":"0,18 mm"},{"name":"","range":"3000 mm do 5000 mm","cmc":"0,25 mm"}],"parameters_en":[{"name":"","range":"0 mm to 1000 mm","cmc":"0,12 mm"},{"name":"","range":"1000 mm do 3000 mm","cmc":"0,18 mm"},{"name":"","range":"3000 mm do 5000 mm","cmc":"0,25 mm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem przymiaru sztywnego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparison method using a rigid rule; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem przymiaru sztywnego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparison method using a rigid rule","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 1000 mm CMC 0,12 mm\n1000 mm do 3000 mm CMC 0,18 mm\n3000 mm do 5000 mm CMC 0,25 mm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem przymiaru sztywnego; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.21","norm_bases":["IW5.8.21"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przymiary półsztywne\nPrzymiary sztywne Wzorcowanie — Długość\nZakres:\n0 mm do 1000 mm CMC 0,12 mm\n1000 mm do 3000 mm CMC 0,18 mm\n3000 mm do 5000 mm CMC 0,25 mm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem przymiaru sztywnego; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.21 Przymiary polsztywne\nPrzymiary sztywne Wzorcowanie — Dlugosc\nZakres:\n0 mm do 1000 mm CMC 0,12 mm\n1000 mm do 3000 mm CMC 0,18 mm\n3000 mm do 5000 mm CMC 0,25 mm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem przymiaru sztywnego; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.21","search_en":"Semi-rigid rules Rigid rules Calibration — Length Internal procedure; Comparison method using a rigid rule; At permanent location (S) Length Internal procedure Comparison method using a rigid rule At permanent location (S) Internal procedure IW5.8.21","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":36,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.21","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 1000 mm","cmc":"0,12 mm"},{"name":"","range":"1000 mm do 3000 mm","cmc":"0,18 mm"},{"name":"","range":"3000 mm bis 5000 mm","cmc":"0,25 mm"}],"reference_de":"Internes Verfahren IW5.8.21","regulatory_area_de":"Länge","search_de":"Halbstarre Maßstäbe Starre Maßstäbe Kalibrierung — Länge Interne Verfahrensanweisung; Vergleichsverfahren unter Verwendung eines starren Maßstabs; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren unter Verwendung eines starren Maßstabs Am festen Standort (S) Internes Verfahren IW5.8.21","technique_de":"Interne Verfahrensanweisung; Vergleichsverfahren unter Verwendung eines starren Maßstabs; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren unter Verwendung eines starren Maßstabs","Am festen Standort (S)"],"test_object_de":"Halbstarre Maßstäbe\nStarre Maßstäbe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"0,12 mm"},{"name":"","range":"1000 mm do 3000 mm","cmc":"0,18 mm"},{"name":"","range":"3000 mm do 5000 mm","cmc":"0,25 mm"}],"reference_zh":"内部程序 IW5.8.21","regulatory_area_zh":"长度","search_zh":"半刚性量尺 刚性量尺 校准 — 长度 内部程序；使用刚性量尺的比较法；在固定地点 (S) 长度 内部程序 使用刚性量尺的比较法 在固定地点 (S) 内部程序 IW5.8.21","technique_zh":"内部程序；使用刚性量尺的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用刚性量尺的比较法","在固定地点 (S)"],"test_object_zh":"半刚性量尺\n刚性量尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 1000 mm","cmc":"0,12 mm"},{"name":"","range":"1000 mm do 3000 mm","cmc":"0,18 mm"},{"name":"","range":"3000 mm do 5000 mm","cmc":"0,25 mm"}],"reference_cs":"Vnitřní postup IW5.8.21","regulatory_area_cs":"Délka","search_cs":"Polotuhá délková měřidla Tuhá délková měřidla Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím tuhého měřítka; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím tuhého měřítka Ve stálé lokalitě (S) Vnitřní postup IW5.8.21","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím tuhého měřítka; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím tuhého měřítka","Ve stálé lokalitě (S)"],"test_object_cs":"Polotuhá délková měřidla\nTuhá délková měřidla"},{"_id":"9a43ebed7f0294ab06ad35fc","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Przymiary wstęgowe","test_object_en":"Measuring tapes","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 2000 mm","cmc":"0,14 mm"},{"name":"","range":"2000 mm do 5000 mm","cmc":"0,25 mm"},{"name":"","range":"5000 mm do 8000 mm","cmc":"0,33 mm"},{"name":"","range":"8000 mm do 10000 mm","cmc":"0,37 mm"},{"name":"","range":"10000 mm do 15000 mm","cmc":"0,45 mm"}],"parameters_en":[{"name":"","range":"0 mm to 2000 mm","cmc":"0,14 mm"},{"name":"","range":"2000 mm to 5000 mm","cmc":"0,25 mm"},{"name":"","range":"5000 mm to 8000 mm","cmc":"0,33 mm"},{"name":"","range":"8000 mm to 10000 mm","cmc":"0,37 mm"},{"name":"","range":"10000 mm to 15000 mm","cmc":"0,45 mm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem przymiaru sztywnego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparison method using a rigid rule; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem przymiaru sztywnego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparison method using a rigid rule","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 2000 mm CMC 0,14 mm\n2000 mm do 5000 mm CMC 0,25 mm\n5000 mm do 8000 mm CMC 0,33 mm\n8000 mm do 10000 mm CMC 0,37 mm\n10000 mm do 15000 mm CMC 0,45 mm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem przymiaru sztywnego; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.21","norm_bases":["IW5.8.21"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przymiary wstęgowe Wzorcowanie — Długość\nZakres:\n0 mm do 2000 mm CMC 0,14 mm\n2000 mm do 5000 mm CMC 0,25 mm\n5000 mm do 8000 mm CMC 0,33 mm\n8000 mm do 10000 mm CMC 0,37 mm\n10000 mm do 15000 mm CMC 0,45 mm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem przymiaru sztywnego; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.21 Przymiary wstegowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 2000 mm CMC 0,14 mm\n2000 mm do 5000 mm CMC 0,25 mm\n5000 mm do 8000 mm CMC 0,33 mm\n8000 mm do 10000 mm CMC 0,37 mm\n10000 mm do 15000 mm CMC 0,45 mm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem przymiaru sztywnego; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.21","search_en":"Measuring tapes Calibration — Length Internal procedure; Comparison method using a rigid rule; At permanent location (S) Length Internal procedure Comparison method using a rigid rule At permanent location (S) Internal procedure IW5.8.21","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":37,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.21","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 2000 mm","cmc":"0,14 mm"},{"name":"","range":"2000 mm to 5000 mm","cmc":"0,25 mm"},{"name":"","range":"5000 mm bis 8000 mm","cmc":"0,33 mm"},{"name":"","range":"8000 mm to 10000 mm","cmc":"0,37 mm"},{"name":"","range":"10000 mm to 15000 mm","cmc":"0,45 mm"}],"reference_de":"Internes Verfahren IW5.8.21","regulatory_area_de":"Länge","search_de":"Bandmaße Kalibrierung — Länge Interne Verfahrensanweisung; Vergleichsverfahren unter Verwendung eines starren Maßstabs; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren unter Verwendung eines starren Maßstabs Am festen Standort (S) Internes Verfahren IW5.8.21","technique_de":"Interne Verfahrensanweisung; Vergleichsverfahren unter Verwendung eines starren Maßstabs; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren unter Verwendung eines starren Maßstabs","Am festen Standort (S)"],"test_object_de":"Bandmaße","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 2000 mm","cmc":"0,14 mm"},{"name":"","range":"2000 mm to 5000 mm","cmc":"0,25 mm"},{"name":"","range":"5000 mm to 8000 mm","cmc":"0,33 mm"},{"name":"","range":"8000 mm to 10000 mm","cmc":"0,37 mm"},{"name":"","range":"10000 mm to 15000 mm","cmc":"0,45 mm"}],"reference_zh":"内部程序 IW5.8.21","regulatory_area_zh":"长度","search_zh":"卷尺 校准 — 长度 内部程序；使用刚性量尺的比较法；在固定地点 (S) 长度 内部程序 使用刚性量尺的比较法 在固定地点 (S) 内部程序 IW5.8.21","technique_zh":"内部程序；使用刚性量尺的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用刚性量尺的比较法","在固定地点 (S)"],"test_object_zh":"卷尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 2000 mm","cmc":"0,14 mm"},{"name":"","range":"2000 mm to 5000 mm","cmc":"0,25 mm"},{"name":"","range":"5000 mm to 8000 mm","cmc":"0,33 mm"},{"name":"","range":"8000 mm to 10000 mm","cmc":"0,37 mm"},{"name":"","range":"10000 mm to 15000 mm","cmc":"0,45 mm"}],"reference_cs":"Vnitřní postup IW5.8.21","regulatory_area_cs":"Délka","search_cs":"Měřicí pásma Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím tuhého měřítka; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím tuhého měřítka Ve stálé lokalitě (S) Vnitřní postup IW5.8.21","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím tuhého měřítka; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím tuhého měřítka","Ve stálé lokalitě (S)"],"test_object_cs":"Měřicí pásma"},{"_id":"aaaefaed5dc5c96284139965","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Spoinomierze","test_object_en":"Weld gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- pomiar wysokości spoin czołowych","range":"0 mm do 15 mm","cmc":"0,06 mm"},{"name":"- pomiar wysokości spoin pachwinowych","range":"0 mm do 20 mm","cmc":"0,06 mm"},{"name":"- pomiar grubości spoin pachwinowych","range":"0 mm do 15 mm","cmc":"0,06 mm"},{"name":"- pomiar szerokości spoin","range":"0 mm do 60 mm","cmc":"0,6 mm"},{"name":"- pomiar głębokości podcięcia","range":"0 mm do 6 mm","cmc":"0,06 mm"}],"parameters_en":[{"name":"- measurement of butt weld height","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"- measurement of fillet weld height","range":"0 mm to 20 mm","cmc":"0,06 mm"},{"name":"- measurement of fillet weld throat thickness","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"- measurement of weld width","range":"0 mm to 60 mm","cmc":"0,6 mm"},{"name":"- measurement of undercut depth","range":"0 mm to 6 mm","cmc":"0,06 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks and measuring rollers; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks and measuring rollers","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- pomiar wysokości spoin czołowych 0 mm do 15 mm CMC 0,06 mm\n- pomiar wysokości spoin pachwinowych 0 mm do 20 mm CMC 0,06 mm\n- pomiar grubości spoin pachwinowych 0 mm do 15 mm CMC 0,06 mm\n- pomiar szerokości spoin 0 mm do 60 mm CMC 0,6 mm\n- pomiar głębokości podcięcia 0 mm do 6 mm CMC 0,06 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.40","norm_bases":["IW5.8.40"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Spoinomierze Wzorcowanie — Długość\nZakres:\n- pomiar wysokości spoin czołowych 0 mm do 15 mm CMC 0,06 mm\n- pomiar wysokości spoin pachwinowych 0 mm do 20 mm CMC 0,06 mm\n- pomiar grubości spoin pachwinowych 0 mm do 15 mm CMC 0,06 mm\n- pomiar szerokości spoin 0 mm do 60 mm CMC 0,6 mm\n- pomiar głębokości podcięcia 0 mm do 6 mm CMC 0,06 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.40 Spoinomierze Wzorcowanie — Dlugosc\nZakres:\n- pomiar wysokosci spoin czolowych 0 mm do 15 mm CMC 0,06 mm\n- pomiar wysokosci spoin pachwinowych 0 mm do 20 mm CMC 0,06 mm\n- pomiar grubosci spoin pachwinowych 0 mm do 15 mm CMC 0,06 mm\n- pomiar szerokosci spoin 0 mm do 60 mm CMC 0,6 mm\n- pomiar glebokosci podciecia 0 mm do 6 mm CMC 0,06 mm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych oraz waleczkow pomiarowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.40","search_en":"Weld gauges Calibration — Length Internal procedure; Direct method using gauge blocks and measuring rollers; At permanent location (S) Length Internal procedure Direct method using gauge blocks and measuring rollers At permanent location (S) - measurement of butt weld height - measurement of fillet weld height - measurement of fillet weld throat thickness - measurement of weld width - measurement of undercut depth Internal procedure IW5.8.40","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":38,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.40","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Messung der Stumpfnahthöhe","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"- Messung der Kehlnahthöhe","range":"0 mm to 20 mm","cmc":"0,06 mm"},{"name":"- Messung der Kehlnahtdicke","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"- Messung der Nahtbreite","range":"0 mm to 60 mm","cmc":"0,6 mm"},{"name":"- Messung der Einbrandkerbentiefe","range":"0 mm to 6 mm","cmc":"0,06 mm"}],"reference_de":"Internes Verfahren IW5.8.40","regulatory_area_de":"Länge","search_de":"Schweißnahtlehren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Parallelendmaßen und Messrollen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen und Messrollen Am festen Standort (S) - Messung der Stumpfnahthöhe - Messung der Kehlnahthöhe - Messung der Kehlnahtdicke - Messung der Nahtbreite - Messung der Einbrandkerbentiefe Internes Verfahren IW5.8.40","technique_de":"Internes Verfahren; Direktes Verfahren mit Parallelendmaßen und Messrollen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen und Messrollen","Am festen Standort (S)"],"test_object_de":"Schweißnahtlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 对接焊缝余高测量","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"- 角焊缝高度测量","range":"0 mm to 20 mm","cmc":"0,06 mm"},{"name":"- 角焊缝厚度测量","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"- 焊缝宽度测量","range":"0 mm to 60 mm","cmc":"0,6 mm"},{"name":"- 咬边深度测量","range":"0 mm to 6 mm","cmc":"0,06 mm"}],"reference_zh":"内部程序 IW5.8.40","regulatory_area_zh":"长度","search_zh":"焊缝量规 校准 — 长度 内部程序；使用量块和测量棒的直接法；在固定地点 (S) 长度 内部程序 使用量块和测量棒的直接法 在固定地点 (S) - 对接焊缝余高测量 - 角焊缝高度测量 - 角焊缝厚度测量 - 焊缝宽度测量 - 咬边深度测量 内部程序 IW5.8.40","technique_zh":"内部程序；使用量块和测量棒的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块和测量棒的直接法","在固定地点 (S)"],"test_object_zh":"焊缝量规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- měření výšky tupých svarů","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"- měření výšky koutových svarů","range":"0 mm to 20 mm","cmc":"0,06 mm"},{"name":"- měření tloušťky koutových svarů","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"- měření šířky svarů","range":"0 mm to 60 mm","cmc":"0,6 mm"},{"name":"- měření hloubky zápalu","range":"0 mm to 6 mm","cmc":"0,06 mm"}],"reference_cs":"Vnitřní postup IW5.8.40","regulatory_area_cs":"Délka","search_cs":"Svarové měrky Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek a měřicích válečků; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek a měřicích válečků Ve stálé lokalitě (S) - měření výšky tupých svarů - měření výšky koutových svarů - měření tloušťky koutových svarů - měření šířky svarů - měření hloubky zápalu Vnitřní postup IW5.8.40","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek a měřicích válečků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek a měřicích válečků","Ve stálé lokalitě (S)"],"test_object_cs":"Svarové měrky"},{"_id":"a663251bfeb2a00316f47d4f","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Spoinomierze","test_object_en":"Weld gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- wysokość spoiny czołowej","range":"0 mm do 30 mm","cmc":"6 µm"},{"name":"- grubość spoiny pachwinowej","range":"0 mm do 30 mm","cmc":"12 µm"}],"parameters_en":[{"name":"- butt weld height","range":"0 mm to 30 mm","cmc":"6 µm"},{"name":"- fillet weld throat thickness","range":"0 mm to 30 mm","cmc":"12 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- wysokość spoiny czołowej 0 mm do 30 mm CMC 6 µm\n- grubość spoiny pachwinowej 0 mm do 30 mm CMC 12 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.33","norm_bases":["IW5.8.33"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Spoinomierze Wzorcowanie — Długość\nZakres:\n- wysokość spoiny czołowej 0 mm do 30 mm CMC 6 µm\n- grubość spoiny pachwinowej 0 mm do 30 mm CMC 12 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.33 Spoinomierze Wzorcowanie — Dlugosc\nZakres:\n- wysokosc spoiny czolowej 0 mm do 30 mm CMC 6 µm\n- grubosc spoiny pachwinowej 0 mm do 30 mm CMC 12 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.33","search_en":"Weld gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) - butt weld height - fillet weld throat thickness Internal procedure IW5.8.33","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":39,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.33","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Stumpfnahthöhe","range":"0 mm to 30 mm","cmc":"6 µm"},{"name":"- Kehlnahtdicke","range":"0 mm to 30 mm","cmc":"12 µm"}],"reference_de":"Internes Verfahren IW5.8.33","regulatory_area_de":"Länge","search_de":"Schweißnahtlehren Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) - Stumpfnahthöhe - Kehlnahtdicke Internes Verfahren IW5.8.33","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Schweißnahtlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 对接焊缝余高","range":"0 mm to 30 mm","cmc":"6 µm"},{"name":"- 角焊缝厚度","range":"0 mm to 30 mm","cmc":"12 µm"}],"reference_zh":"内部程序 IW5.8.33","regulatory_area_zh":"长度","search_zh":"焊缝量规 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) - 对接焊缝余高 - 角焊缝厚度 内部程序 IW5.8.33","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"焊缝量规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- výška tupého svaru","range":"0 mm to 30 mm","cmc":"6 µm"},{"name":"- tloušťka koutového svaru","range":"0 mm to 30 mm","cmc":"12 µm"}],"reference_cs":"Vnitřní postup IW5.8.33","regulatory_area_cs":"Délka","search_cs":"Svarové měrky Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) - výška tupého svaru - tloušťka koutového svaru Vnitřní postup IW5.8.33","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Svarové měrky"},{"_id":"9772c2a29d2279cac86f99e4","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Sprawdziany gwintowe pierścieniowe stożkowe","test_object_en":"Taper thread ring gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"średnica podziałowa d2","range":"7 mm do 87 mm","cmc":"5,0 µm"}],"parameters_en":[{"name":"pitch diameter d2","range":"7 mm to 87 mm","cmc":"5,0 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using the Trimos Labconcept Premium 500 length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nśrednica podziałowa d2 7 mm do 87 mm CMC 5,0 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.46","norm_bases":["IW5.8.46"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany gwintowe pierścieniowe stożkowe Wzorcowanie — Długość\nśrednica podziałowa d2 7 mm do 87 mm CMC 5,0 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.46 Sprawdziany gwintowe pierscieniowe stozkowe Wzorcowanie — Dlugosc\nsrednica podzialowa d2 7 mm do 87 mm CMC 5,0 µm\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.46","search_en":"Taper thread ring gauges Calibration — Length Internal procedure; Indirect method using the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S) Length Internal procedure Indirect method using the Trimos Labconcept Premium 500 length measuring machine At permanent location (S) pitch diameter d2 Internal procedure IW5.8.46","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":40,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.46","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"Flankendurchmesser d2","range":"7 mm to 87 mm","cmc":"5,0 µm"}],"reference_de":"Internes Verfahren IW5.8.46","regulatory_area_de":"Länge","search_de":"Kegelige Gewindelehrringe Kalibrierung — Länge Internes Verfahren; Indirektes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S) Länge Internes Verfahren Indirektes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 Am festen Standort (S) Flankendurchmesser d2 Internes Verfahren IW5.8.46","technique_de":"Internes Verfahren; Indirektes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500","Am festen Standort (S)"],"test_object_de":"Kegelige Gewindelehrringe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"中径d2","range":"7 mm to 87 mm","cmc":"5,0 µm"}],"reference_zh":"内部程序 IW5.8.46","regulatory_area_zh":"长度","search_zh":"锥度螺纹环规 校准 — 长度 内部程序；使用Trimos Labconcept Premium 500测长仪的间接法；在固定地点 (S) 长度 内部程序 使用Trimos Labconcept Premium 500测长仪的间接法 在固定地点 (S) 中径d2 内部程序 IW5.8.46","technique_zh":"内部程序；使用Trimos Labconcept Premium 500测长仪的间接法；在固定地点 (S)","techniques_zh":["内部程序","使用Trimos Labconcept Premium 500测长仪的间接法","在固定地点 (S)"],"test_object_zh":"锥度螺纹环规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"střední průměr d2","range":"7 mm to 87 mm","cmc":"5,0 µm"}],"reference_cs":"Vnitřní postup IW5.8.46","regulatory_area_cs":"Délka","search_cs":"Kuželové závitové kroužky Kalibrace — Délka Vnitřní postup; Nepřímá metoda s použitím délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S) Délka Vnitřní postup Nepřímá metoda s použitím délkoměru Trimos Labconcept Premium 500 Ve stálé lokalitě (S) střední průměr d2 Vnitřní postup IW5.8.46","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím délkoměru Trimos Labconcept Premium 500","Ve stálé lokalitě (S)"],"test_object_cs":"Kuželové závitové kroužky"},{"_id":"5770138276babf2d214e5746","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Sprawdziany gwintowe pierścieniowe walcowe","test_object_en":"Cylindrical thread ring gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"średnica podziałowa d2","range":"2,1 mm do 50 mm","cmc":"3,0 µm"},{"name":"średnica podziałowa d2","range":"50 mm do 112 mm","cmc":"3,1 µm"},{"name":"średnica podziałowa d2","range":"112 mm do 174 mm","cmc":"3,7 µm"}],"parameters_en":[{"name":"pitch diameter d2","range":"2,1 mm to 50 mm","cmc":"3,0 µm"},{"name":"pitch diameter d2","range":"50 mm to 112 mm","cmc":"3,1 µm"},{"name":"pitch diameter d2","range":"112 mm to 174 mm","cmc":"3,7 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\nśrednica podziałowa d2 2,1 mm do 50 mm CMC 3,0 µm\nśrednica podziałowa d2 50 mm do 112 mm CMC 3,1 µm\nśrednica podziałowa d2 112 mm do 174 mm CMC 3,7 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.45 w oparciu o EURAMET cg-10 Version 2.1 (12/2012)","norm_bases":["IW5.8.45","EURAMET cg-10 Version 2.1 (12/2012)"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany gwintowe pierścieniowe walcowe Wzorcowanie — Długość\nZakres:\nśrednica podziałowa d2 2,1 mm do 50 mm CMC 3,0 µm\nśrednica podziałowa d2 50 mm do 112 mm CMC 3,1 µm\nśrednica podziałowa d2 112 mm do 174 mm CMC 3,7 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.45 w oparciu o EURAMET cg-10 Version 2.1 (12/2012) Sprawdziany gwintowe pierscieniowe walcowe Wzorcowanie — Dlugosc\nZakres:\nsrednica podzialowa d2 2,1 mm do 50 mm CMC 3,0 µm\nsrednica podzialowa d2 50 mm do 112 mm CMC 3,1 µm\nsrednica podzialowa d2 112 mm do 174 mm CMC 3,7 µm\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500 wyposazonego w czujnik elektroniczny; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.45 w oparciu o EURAMET cg-10 Version 2.1 (12/2012)","search_en":"Cylindrical thread ring gauges Calibration — Length Internal procedure; Indirect method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe; At permanent location (S) Length Internal procedure Indirect method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe At permanent location (S) pitch diameter d2 pitch diameter d2 pitch diameter d2 Internal procedure IW5.8.45 based on EURAMET cg-10 Version 2.1 (12/2012)","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":41,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.45 based on EURAMET cg-10 Version 2.1 (12/2012)","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"Flankendurchmesser d2","range":"2,1 mm to 50 mm","cmc":"3,0 µm"},{"name":"Flankendurchmesser d2","range":"50 mm to 112 mm","cmc":"3,1 µm"},{"name":"Flankendurchmesser d2","range":"112 mm to 174 mm","cmc":"3,7 µm"}],"reference_de":"Internes Verfahren IW5.8.45 auf Grundlage von EURAMET cg-10 Version 2.1 (12/2012)","regulatory_area_de":"Länge","search_de":"Zylindrische Gewindelehrringe Kalibrierung — Länge Internes Verfahren; Indirektes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster; Am festen Standort (S) Länge Internes Verfahren Indirektes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster Am festen Standort (S) Flankendurchmesser d2 Flankendurchmesser d2 Flankendurchmesser d2 Internes Verfahren IW5.8.45 auf Grundlage von EURAMET cg-10 Version 2.1 (12/2012)","technique_de":"Internes Verfahren; Indirektes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster","Am festen Standort (S)"],"test_object_de":"Zylindrische Gewindelehrringe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"中径d2","range":"2,1 mm to 50 mm","cmc":"3,0 µm"},{"name":"中径d2","range":"50 mm to 112 mm","cmc":"3,1 µm"},{"name":"中径d2","range":"112 mm to 174 mm","cmc":"3,7 µm"}],"reference_zh":"内部程序 IW5.8.45 依据EURAMET cg-10 Version 2.1 (12/2012)","regulatory_area_zh":"长度","search_zh":"圆柱螺纹环规 校准 — 长度 内部程序；使用配电子测头的Trimos Labconcept Premium 500测长仪的间接法；在固定地点 (S) 长度 内部程序 使用配电子测头的Trimos Labconcept Premium 500测长仪的间接法 在固定地点 (S) 中径d2 中径d2 中径d2 内部程序 IW5.8.45 依据EURAMET cg-10 Version 2.1 (12/2012)","technique_zh":"内部程序；使用配电子测头的Trimos Labconcept Premium 500测长仪的间接法；在固定地点 (S)","techniques_zh":["内部程序","使用配电子测头的Trimos Labconcept Premium 500测长仪的间接法","在固定地点 (S)"],"test_object_zh":"圆柱螺纹环规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"střední průměr d2","range":"2,1 mm to 50 mm","cmc":"3,0 µm"},{"name":"střední průměr d2","range":"50 mm to 112 mm","cmc":"3,1 µm"},{"name":"střední průměr d2","range":"112 mm to 174 mm","cmc":"3,7 µm"}],"reference_cs":"Vnitřní postup IW5.8.45 na základě EURAMET cg-10 Version 2.1 (12/2012)","regulatory_area_cs":"Délka","search_cs":"Závitové kroužky válcové Kalibrace — Délka Vnitřní postup; Nepřímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem; Ve stálé lokalitě (S) Délka Vnitřní postup Nepřímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem Ve stálé lokalitě (S) střední průměr d2 střední průměr d2 střední průměr d2 Vnitřní postup IW5.8.45 na základě EURAMET cg-10 Version 2.1 (12/2012)","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem","Ve stálé lokalitě (S)"],"test_object_cs":"Závitové kroužky válcové"},{"_id":"aef84755f7cc72d18899455d","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Sprawdziany gwintowe trzpieniowe stożkowe","test_object_en":"Taper thread plug gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"średnica podziałowa d2","range":"9 mm do 112 mm","cmc":"5,0 µm"}],"parameters_en":[{"name":"pitch diameter d2","range":"9 mm to 112 mm","cmc":"5,0 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using the Trimos Labconcept Premium 500 length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nśrednica podziałowa d2 9 mm do 112 mm CMC 5,0 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.46","norm_bases":["IW5.8.46"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany gwintowe trzpieniowe stożkowe Wzorcowanie — Długość\nśrednica podziałowa d2 9 mm do 112 mm CMC 5,0 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.46 Sprawdziany gwintowe trzpieniowe stozkowe Wzorcowanie — Dlugosc\nsrednica podzialowa d2 9 mm do 112 mm CMC 5,0 µm\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.46","search_en":"Taper thread plug gauges Calibration — Length Internal procedure; Indirect method using the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S) Length Internal procedure Indirect method using the Trimos Labconcept Premium 500 length measuring machine At permanent location (S) pitch diameter d2 Internal procedure IW5.8.46","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":42,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.46","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"Flankendurchmesser d2","range":"9 mm to 112 mm","cmc":"5,0 µm"}],"reference_de":"Internes Verfahren IW5.8.46","regulatory_area_de":"Länge","search_de":"Kegelige Gewindelehrdorne Kalibrierung — Länge Internes Verfahren; Indirektes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S) Länge Internes Verfahren Indirektes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 Am festen Standort (S) Flankendurchmesser d2 Internes Verfahren IW5.8.46","technique_de":"Internes Verfahren; Indirektes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500","Am festen Standort (S)"],"test_object_de":"Kegelige Gewindelehrdorne","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"中径d2","range":"9 mm to 112 mm","cmc":"5,0 µm"}],"reference_zh":"内部程序 IW5.8.46","regulatory_area_zh":"长度","search_zh":"锥度螺纹塞规 校准 — 长度 内部程序；使用Trimos Labconcept Premium 500测长仪的间接法；在固定地点 (S) 长度 内部程序 使用Trimos Labconcept Premium 500测长仪的间接法 在固定地点 (S) 中径d2 内部程序 IW5.8.46","technique_zh":"内部程序；使用Trimos Labconcept Premium 500测长仪的间接法；在固定地点 (S)","techniques_zh":["内部程序","使用Trimos Labconcept Premium 500测长仪的间接法","在固定地点 (S)"],"test_object_zh":"锥度螺纹塞规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"střední průměr d2","range":"9 mm to 112 mm","cmc":"5,0 µm"}],"reference_cs":"Vnitřní postup IW5.8.46","regulatory_area_cs":"Délka","search_cs":"Kuželové závitové kalibry Kalibrace — Délka Vnitřní postup; Nepřímá metoda s použitím délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S) Délka Vnitřní postup Nepřímá metoda s použitím délkoměru Trimos Labconcept Premium 500 Ve stálé lokalitě (S) střední průměr d2 Vnitřní postup IW5.8.46","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím délkoměru Trimos Labconcept Premium 500","Ve stálé lokalitě (S)"],"test_object_cs":"Kuželové závitové kalibry"},{"_id":"3ff854051393ff3f1035b371","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Sprawdziany gwintowe trzpieniowe walcowe","test_object_en":"Cylindrical thread plug gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"średnica podziałowa d2","range":"1,5 mm do 100 mm","cmc":"3,0 µm"},{"name":"średnica podziałowa d2","range":"100 mm do 125 mm","cmc":"3,2 µm"}],"parameters_en":[{"name":"pitch diameter d2","range":"1,5 mm to 100 mm","cmc":"3,0 µm"},{"name":"pitch diameter d2","range":"100 mm to 125 mm","cmc":"3,2 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem wałeczków pomiarowych i długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using measuring rollers and the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem wałeczków pomiarowych i długościomierza Trimos Labconcept Premium 500","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using measuring rollers and the Trimos Labconcept Premium 500 length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\nśrednica podziałowa d2 1,5 mm do 100 mm CMC 3,0 µm\nśrednica podziałowa d2 100 mm do 125 mm CMC 3,2 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem wałeczków pomiarowych i długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.7 w oparciu o EURAMET cg-10 Version 2.1 (12/2012)","norm_bases":["IW5.8.7","EURAMET cg-10 Version 2.1 (12/2012)"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany gwintowe trzpieniowe walcowe Wzorcowanie — Długość\nZakres:\nśrednica podziałowa d2 1,5 mm do 100 mm CMC 3,0 µm\nśrednica podziałowa d2 100 mm do 125 mm CMC 3,2 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem wałeczków pomiarowych i długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.7 w oparciu o EURAMET cg-10 Version 2.1 (12/2012) Sprawdziany gwintowe trzpieniowe walcowe Wzorcowanie — Dlugosc\nZakres:\nsrednica podzialowa d2 1,5 mm do 100 mm CMC 3,0 µm\nsrednica podzialowa d2 100 mm do 125 mm CMC 3,2 µm\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem waleczkow pomiarowych i dlugosciomierza Trimos Labconcept Premium 500; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.7 w oparciu o EURAMET cg-10 Version 2.1 (12/2012)","search_en":"Cylindrical thread plug gauges Calibration — Length Internal procedure; Indirect method using measuring rollers and the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S) Length Internal procedure Indirect method using measuring rollers and the Trimos Labconcept Premium 500 length measuring machine At permanent location (S) pitch diameter d2 pitch diameter d2 Internal procedure IW5.8.7 based on EURAMET cg-10 Version 2.1 (12/2012)","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":43,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.7 based on EURAMET cg-10 Version 2.1 (12/2012)","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"Flankendurchmesser d2","range":"1,5 mm to 100 mm","cmc":"3,0 µm"},{"name":"Flankendurchmesser d2","range":"100 mm bis 125 mm","cmc":"3,2 µm"}],"reference_de":"Internes Verfahren IW5.8.7 auf Grundlage von EURAMET cg-10 Version 2.1 (12/2012)","regulatory_area_de":"Länge","search_de":"Zylindrische Gewindelehrdorne Kalibrierung — Länge Internes Verfahren; Indirektes Verfahren mit Messrollen und dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S) Länge Internes Verfahren Indirektes Verfahren mit Messrollen und dem Längenmessgerät Trimos Labconcept Premium 500 Am festen Standort (S) Flankendurchmesser d2 Flankendurchmesser d2 Internes Verfahren IW5.8.7 auf Grundlage von EURAMET cg-10 Version 2.1 (12/2012)","technique_de":"Internes Verfahren; Indirektes Verfahren mit Messrollen und dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit Messrollen und dem Längenmessgerät Trimos Labconcept Premium 500","Am festen Standort (S)"],"test_object_de":"Zylindrische Gewindelehrdorne","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"中径d2","range":"1,5 mm to 100 mm","cmc":"3,0 µm"},{"name":"中径d2","range":"100 mm 至 125 mm","cmc":"3,2 µm"}],"reference_zh":"内部程序 IW5.8.7 依据EURAMET cg-10 Version 2.1 (12/2012)","regulatory_area_zh":"长度","search_zh":"圆柱螺纹塞规 校准 — 长度 内部程序；使用测量棒和Trimos Labconcept Premium 500测长仪的间接法；在固定地点 (S) 长度 内部程序 使用测量棒和Trimos Labconcept Premium 500测长仪的间接法 在固定地点 (S) 中径d2 中径d2 内部程序 IW5.8.7 依据EURAMET cg-10 Version 2.1 (12/2012)","technique_zh":"内部程序；使用测量棒和Trimos Labconcept Premium 500测长仪的间接法；在固定地点 (S)","techniques_zh":["内部程序","使用测量棒和Trimos Labconcept Premium 500测长仪的间接法","在固定地点 (S)"],"test_object_zh":"圆柱螺纹塞规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"střední průměr d2","range":"1,5 mm to 100 mm","cmc":"3,0 µm"},{"name":"střední průměr d2","range":"100 mm do 125 mm","cmc":"3,2 µm"}],"reference_cs":"Vnitřní postup IW5.8.7 na základě EURAMET cg-10 Version 2.1 (12/2012)","regulatory_area_cs":"Délka","search_cs":"Závitové trny válcové Kalibrace — Délka Vnitřní postup; Nepřímá metoda s použitím měřicích válečků a délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S) Délka Vnitřní postup Nepřímá metoda s použitím měřicích válečků a délkoměru Trimos Labconcept Premium 500 Ve stálé lokalitě (S) střední průměr d2 střední průměr d2 Vnitřní postup IW5.8.7 na základě EURAMET cg-10 Version 2.1 (12/2012)","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím měřicích válečků a délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím měřicích válečků a délkoměru Trimos Labconcept Premium 500","Ve stálé lokalitě (S)"],"test_object_cs":"Závitové trny válcové"},{"_id":"80fd2a316f0b9b0e2ff4e017","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Sprawdziany pierścieniowe gładkie","test_object_en":"Plain ring gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"2 mm do 30 mm","cmc":"1,8 µm"}],"parameters_en":[{"name":"","range":"2 mm to 30 mm","cmc":"1,8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n2 mm do 30 mm CMC 1,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.44 w oparciu o EURAMET cg-6 Version 2.0 (03/2011)","norm_bases":["IW5.8.44","EURAMET cg-6 Version 2.0 (03/2011)"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany pierścieniowe gładkie Wzorcowanie — Długość\n2 mm do 30 mm CMC 1,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.44 w oparciu o EURAMET cg-6 Version 2.0 (03/2011) Sprawdziany pierscieniowe gladkie Wzorcowanie — Dlugosc\n2 mm do 30 mm CMC 1,8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500 wyposazonego w czujnik elektroniczny; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.44 w oparciu o EURAMET cg-6 Version 2.0 (03/2011)","search_en":"Plain ring gauges Calibration — Length Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe; At permanent location (S) Length Internal procedure Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe At permanent location (S) Internal procedure IW5.8.44 based on EURAMET cg-6 Version 2.0 (03/2011)","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":44,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.44 based on EURAMET cg-6 Version 2.0 (03/2011)","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"2 mm to 30 mm","cmc":"1,8 µm"}],"reference_de":"Internes Verfahren IW5.8.44 auf Grundlage von EURAMET cg-6 Version 2.0 (03/2011)","regulatory_area_de":"Länge","search_de":"Glatte Lehrringe Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster Am festen Standort (S) Internes Verfahren IW5.8.44 auf Grundlage von EURAMET cg-6 Version 2.0 (03/2011)","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster","Am festen Standort (S)"],"test_object_de":"Glatte Lehrringe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"2 mm to 30 mm","cmc":"1,8 µm"}],"reference_zh":"内部程序 IW5.8.44 依据EURAMET cg-6 Version 2.0 (03/2011)","regulatory_area_zh":"长度","search_zh":"光滑环规 校准 — 长度 内部程序；使用配电子测头的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S) 长度 内部程序 使用配电子测头的Trimos Labconcept Premium 500测长仪的直接法 在固定地点 (S) 内部程序 IW5.8.44 依据EURAMET cg-6 Version 2.0 (03/2011)","technique_zh":"内部程序；使用配电子测头的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用配电子测头的Trimos Labconcept Premium 500测长仪的直接法","在固定地点 (S)"],"test_object_zh":"光滑环规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"2 mm to 30 mm","cmc":"1,8 µm"}],"reference_cs":"Vnitřní postup IW5.8.44 na základě EURAMET cg-6 Version 2.0 (03/2011)","regulatory_area_cs":"Délka","search_cs":"Hladké kroužky Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem Ve stálé lokalitě (S) Vnitřní postup IW5.8.44 na základě EURAMET cg-6 Version 2.0 (03/2011)","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem","Ve stálé lokalitě (S)"],"test_object_cs":"Hladké kroužky"},{"_id":"9cec4e1e1d976ed0b9e20c7d","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Sprawdziany pierścieniowe gładkie","test_object_en":"Plain ring gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"10 mm do 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm do 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm do 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm do 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm do 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm do 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm do 260 mm","cmc":"2,9 µm"},{"name":"","range":"260 mm do 300 mm","cmc":"3,2 µm"}],"parameters_en":[{"name":"","range":"10 mm to 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm to 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm to 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm to 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm to 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm to 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm to 260 mm","cmc":"2,9 µm"},{"name":"","range":"260 mm to 300 mm","cmc":"3,2 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n10 mm do 50 mm CMC 1,4 µm\n50 mm do 80 mm CMC 1,5 µm\n80 mm do 110 mm CMC 1,7 µm\n110 mm do 150 mm CMC 1,9 µm\n150 mm do 190 mm CMC 2,2 µm\n190 mm do 225 mm CMC 2,4 µm\n225 mm do 260 mm CMC 2,9 µm\n260 mm do 300 mm CMC 3,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.6 w oparciu o EURAMET cg-6 Version 2.0 (03/2011)","norm_bases":["IW5.8.6","EURAMET cg-6 Version 2.0 (03/2011)"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany pierścieniowe gładkie Wzorcowanie — Długość\nZakres:\n10 mm do 50 mm CMC 1,4 µm\n50 mm do 80 mm CMC 1,5 µm\n80 mm do 110 mm CMC 1,7 µm\n110 mm do 150 mm CMC 1,9 µm\n150 mm do 190 mm CMC 2,2 µm\n190 mm do 225 mm CMC 2,4 µm\n225 mm do 260 mm CMC 2,9 µm\n260 mm do 300 mm CMC 3,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.6 w oparciu o EURAMET cg-6 Version 2.0 (03/2011) Sprawdziany pierscieniowe gladkie Wzorcowanie — Dlugosc\nZakres:\n10 mm do 50 mm CMC 1,4 µm\n50 mm do 80 mm CMC 1,5 µm\n80 mm do 110 mm CMC 1,7 µm\n110 mm do 150 mm CMC 1,9 µm\n150 mm do 190 mm CMC 2,2 µm\n190 mm do 225 mm CMC 2,4 µm\n225 mm do 260 mm CMC 2,9 µm\n260 mm do 300 mm CMC 3,2 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500 wyposazonego w kablaki; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.6 w oparciu o EURAMET cg-6 Version 2.0 (03/2011)","search_en":"Plain ring gauges Calibration — Length Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms; At permanent location (S) Length Internal procedure Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms At permanent location (S) Internal procedure IW5.8.6 based on EURAMET cg-6 Version 2.0 (03/2011)","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":45,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.6 based on EURAMET cg-6 Version 2.0 (03/2011)","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"10 mm to 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm to 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm to 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm to 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm to 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm to 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm to 260 mm","cmc":"2,9 µm"},{"name":"","range":"260 mm to 300 mm","cmc":"3,2 µm"}],"reference_de":"Internes Verfahren IW5.8.6 auf Grundlage von EURAMET cg-6 Version 2.0 (03/2011)","regulatory_area_de":"Länge","search_de":"Glatte Lehrringe Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln Am festen Standort (S) Internes Verfahren IW5.8.6 auf Grundlage von EURAMET cg-6 Version 2.0 (03/2011)","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln","Am festen Standort (S)"],"test_object_de":"Glatte Lehrringe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"10 mm to 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm to 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm to 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm to 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm to 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm to 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm to 260 mm","cmc":"2,9 µm"},{"name":"","range":"260 mm to 300 mm","cmc":"3,2 µm"}],"reference_zh":"内部程序 IW5.8.6 依据EURAMET cg-6 Version 2.0 (03/2011)","regulatory_area_zh":"长度","search_zh":"光滑环规 校准 — 长度 内部程序；使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S) 长度 内部程序 使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法 在固定地点 (S) 内部程序 IW5.8.6 依据EURAMET cg-6 Version 2.0 (03/2011)","technique_zh":"内部程序；使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法","在固定地点 (S)"],"test_object_zh":"光滑环规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"10 mm to 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm to 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm to 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm to 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm to 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm to 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm to 260 mm","cmc":"2,9 µm"},{"name":"","range":"260 mm to 300 mm","cmc":"3,2 µm"}],"reference_cs":"Vnitřní postup IW5.8.6 na základě EURAMET cg-6 Version 2.0 (03/2011)","regulatory_area_cs":"Délka","search_cs":"Hladké kroužky Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny Ve stálé lokalitě (S) Vnitřní postup IW5.8.6 na základě EURAMET cg-6 Version 2.0 (03/2011)","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny","Ve stálé lokalitě (S)"],"test_object_cs":"Hladké kroužky"},{"_id":"b79ece7bc50e409e70b6fd67","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Sprawdziany specjalne","test_object_en":"Special gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"5 mm do 50 mm","cmc":"1,8 µm"}],"parameters_en":[{"name":"","range":"5 mm to 50 mm","cmc":"1,8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n5 mm do 50 mm CMC 1,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.48","norm_bases":["IW5.8.48"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany specjalne Wzorcowanie — Długość\n5 mm do 50 mm CMC 1,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w czujnik elektroniczny; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.48 Sprawdziany specjalne Wzorcowanie — Dlugosc\n5 mm do 50 mm CMC 1,8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500 wyposazonego w czujnik elektroniczny; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.48","search_en":"Special gauges Calibration — Length Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe; At permanent location (S) Length Internal procedure Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with an electronic probe At permanent location (S) Internal procedure IW5.8.48","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":46,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.48","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"5 mm to 50 mm","cmc":"1,8 µm"}],"reference_de":"Internes Verfahren IW5.8.48","regulatory_area_de":"Länge","search_de":"Sonderlehren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster Am festen Standort (S) Internes Verfahren IW5.8.48","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit elektronischem Messtaster","Am festen Standort (S)"],"test_object_de":"Sonderlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"5 mm to 50 mm","cmc":"1,8 µm"}],"reference_zh":"内部程序 IW5.8.48","regulatory_area_zh":"长度","search_zh":"专用量规 校准 — 长度 内部程序；使用配电子测头的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S) 长度 内部程序 使用配电子测头的Trimos Labconcept Premium 500测长仪的直接法 在固定地点 (S) 内部程序 IW5.8.48","technique_zh":"内部程序；使用配电子测头的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用配电子测头的Trimos Labconcept Premium 500测长仪的直接法","在固定地点 (S)"],"test_object_zh":"专用量规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"5 mm to 50 mm","cmc":"1,8 µm"}],"reference_cs":"Vnitřní postup IW5.8.48","regulatory_area_cs":"Délka","search_cs":"Speciální kalibry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem Ve stálé lokalitě (S) Vnitřní postup IW5.8.48","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného elektronickým snímačem","Ve stálé lokalitě (S)"],"test_object_cs":"Speciální kalibry"},{"_id":"0df0fd966e9d38c8d1b42e2a","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Sprawdziany specjalne","test_object_en":"Special gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"14 mm do 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm do 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm do 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm do 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm do 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm do 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm do 240 mm","cmc":"2,6 µm"}],"parameters_en":[{"name":"","range":"14 mm to 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm to 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm to 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm to 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm to 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm to 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm to 240 mm","cmc":"2,6 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n14 mm do 50 mm CMC 1,4 µm\n50 mm do 80 mm CMC 1,5 µm\n80 mm do 110 mm CMC 1,7 µm\n110 mm do 150 mm CMC 1,9 µm\n150 mm do 190 mm CMC 2,2 µm\n190 mm do 225 mm CMC 2,4 µm\n225 mm do 240 mm CMC 2,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.47","norm_bases":["IW5.8.47"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany specjalne Wzorcowanie — Długość\nZakres:\n14 mm do 50 mm CMC 1,4 µm\n50 mm do 80 mm CMC 1,5 µm\n80 mm do 110 mm CMC 1,7 µm\n110 mm do 150 mm CMC 1,9 µm\n150 mm do 190 mm CMC 2,2 µm\n190 mm do 225 mm CMC 2,4 µm\n225 mm do 240 mm CMC 2,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.47 Sprawdziany specjalne Wzorcowanie — Dlugosc\nZakres:\n14 mm do 50 mm CMC 1,4 µm\n50 mm do 80 mm CMC 1,5 µm\n80 mm do 110 mm CMC 1,7 µm\n110 mm do 150 mm CMC 1,9 µm\n150 mm do 190 mm CMC 2,2 µm\n190 mm do 225 mm CMC 2,4 µm\n225 mm do 240 mm CMC 2,6 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500 wyposazonego w kablaki; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.47","search_en":"Special gauges Calibration — Length Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms; At permanent location (S) Length Internal procedure Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms At permanent location (S) Internal procedure IW5.8.47","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":47,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.47","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"14 mm to 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm to 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm to 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm to 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm to 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm to 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm to 240 mm","cmc":"2,6 µm"}],"reference_de":"Internes Verfahren IW5.8.47","regulatory_area_de":"Länge","search_de":"Sonderlehren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln Am festen Standort (S) Internes Verfahren IW5.8.47","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln","Am festen Standort (S)"],"test_object_de":"Sonderlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"14 mm to 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm to 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm to 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm to 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm to 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm to 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm to 240 mm","cmc":"2,6 µm"}],"reference_zh":"内部程序 IW5.8.47","regulatory_area_zh":"长度","search_zh":"专用量规 校准 — 长度 内部程序；使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S) 长度 内部程序 使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法 在固定地点 (S) 内部程序 IW5.8.47","technique_zh":"内部程序；使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法","在固定地点 (S)"],"test_object_zh":"专用量规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"14 mm to 50 mm","cmc":"1,4 µm"},{"name":"","range":"50 mm to 80 mm","cmc":"1,5 µm"},{"name":"","range":"80 mm to 110 mm","cmc":"1,7 µm"},{"name":"","range":"110 mm to 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm to 190 mm","cmc":"2,2 µm"},{"name":"","range":"190 mm to 225 mm","cmc":"2,4 µm"},{"name":"","range":"225 mm to 240 mm","cmc":"2,6 µm"}],"reference_cs":"Vnitřní postup IW5.8.47","regulatory_area_cs":"Délka","search_cs":"Speciální kalibry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny Ve stálé lokalitě (S) Vnitřní postup IW5.8.47","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny","Ve stálé lokalitě (S)"],"test_object_cs":"Speciální kalibry"},{"_id":"b14116f8d23993db2a231023","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Sprawdziany tłoczkowe","test_object_en":"Plug gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,0 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,2 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"1,3 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"1,7 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"2,1 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm to 75 mm","cmc":"1,0 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"1,2 µm"},{"name":"","range":"100 mm to 125 mm","cmc":"1,3 µm"},{"name":"","range":"125 mm to 150 mm","cmc":"1,7 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"2,1 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Trimos Labconcept Premium 500 length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 0,9 µm\n50 mm do 75 mm CMC 1,0 µm\n75 mm do 100 mm CMC 1,2 µm\n100 mm do 125 mm CMC 1,3 µm\n125 mm do 150 mm CMC 1,7 µm\n150 mm do 200 mm CMC 2,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.14","norm_bases":["IW5.8.14"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany tłoczkowe Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 0,9 µm\n50 mm do 75 mm CMC 1,0 µm\n75 mm do 100 mm CMC 1,2 µm\n100 mm do 125 mm CMC 1,3 µm\n125 mm do 150 mm CMC 1,7 µm\n150 mm do 200 mm CMC 2,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.14 Sprawdziany tloczkowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 50 mm CMC 0,9 µm\n50 mm do 75 mm CMC 1,0 µm\n75 mm do 100 mm CMC 1,2 µm\n100 mm do 125 mm CMC 1,3 µm\n125 mm do 150 mm CMC 1,7 µm\n150 mm do 200 mm CMC 2,1 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.14","search_en":"Plug gauges Calibration — Length Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S) Length Internal procedure Direct method using the Trimos Labconcept Premium 500 length measuring machine At permanent location (S) Internal procedure IW5.8.14","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":48,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.14","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm bis 75 mm","cmc":"1,0 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"1,2 µm"},{"name":"","range":"100 mm bis 125 mm","cmc":"1,3 µm"},{"name":"","range":"125 mm bis 150 mm","cmc":"1,7 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"2,1 µm"}],"reference_de":"Internes Verfahren IW5.8.14","regulatory_area_de":"Länge","search_de":"Lehrdorne Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 Am festen Standort (S) Internes Verfahren IW5.8.14","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500","Am festen Standort (S)"],"test_object_de":"Lehrdorne","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm 至 75 mm","cmc":"1,0 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"1,2 µm"},{"name":"","range":"100 mm 至 125 mm","cmc":"1,3 µm"},{"name":"","range":"125 mm 至 150 mm","cmc":"1,7 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"2,1 µm"}],"reference_zh":"内部程序 IW5.8.14","regulatory_area_zh":"长度","search_zh":"塞规 校准 — 长度 内部程序；使用Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S) 长度 内部程序 使用Trimos Labconcept Premium 500测长仪的直接法 在固定地点 (S) 内部程序 IW5.8.14","technique_zh":"内部程序；使用Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Trimos Labconcept Premium 500测长仪的直接法","在固定地点 (S)"],"test_object_zh":"塞规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,0 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,2 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"1,3 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"1,7 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"2,1 µm"}],"reference_cs":"Vnitřní postup IW5.8.14","regulatory_area_cs":"Délka","search_cs":"Kalibry trny Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 Ve stálé lokalitě (S) Vnitřní postup IW5.8.14","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibry trny"},{"_id":"cc4d19c1464758ea8610d5b8","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Suwmiarki","test_object_en":"Vernier calipers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 150 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 200 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"31 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"34 µm"},{"name":"","range":"0 mm do 1000 mm","cmc":"38 µm"}],"parameters_en":[{"name":"","range":"0 mm do 150 mm","cmc":"10 µm"},{"name":"","range":"0 mm to 200 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm to 600 mm","cmc":"31 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"34 µm"},{"name":"","range":"0 mm to 1000 mm","cmc":"38 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 10 µm\n0 mm do 200 mm CMC 10 µm\n0 mm do 300 mm CMC 12 µm\n0 mm do 500 mm CMC 17 µm\n0 mm do 600 mm CMC 31 µm\n0 mm do 800 mm CMC 34 µm\n0 mm do 1000 mm CMC 38 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.3","norm_bases":["IW5.8.3"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Suwmiarki Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 10 µm\n0 mm do 200 mm CMC 10 µm\n0 mm do 300 mm CMC 12 µm\n0 mm do 500 mm CMC 17 µm\n0 mm do 600 mm CMC 31 µm\n0 mm do 800 mm CMC 34 µm\n0 mm do 1000 mm CMC 38 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.3 Suwmiarki Wzorcowanie — Dlugosc\nZakres:\n0 mm do 150 mm CMC 10 µm\n0 mm do 200 mm CMC 10 µm\n0 mm do 300 mm CMC 12 µm\n0 mm do 500 mm CMC 17 µm\n0 mm do 600 mm CMC 31 µm\n0 mm do 800 mm CMC 34 µm\n0 mm do 1000 mm CMC 38 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.3","search_en":"Vernier calipers Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.3","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":49,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.3","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 150 mm","cmc":"10 µm"},{"name":"","range":"0 mm bis 200 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm bis 600 mm","cmc":"31 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"34 µm"},{"name":"","range":"0 mm bis 1000 mm","cmc":"38 µm"}],"reference_de":"Internes Verfahren IW5.8.3","regulatory_area_de":"Länge","search_de":"Messschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.3","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Messschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 150 mm","cmc":"10 µm"},{"name":"","range":"0 mm 至 200 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm 至 600 mm","cmc":"31 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"34 µm"},{"name":"","range":"0 mm 至 1000 mm","cmc":"38 µm"}],"reference_zh":"内部程序 IW5.8.3","regulatory_area_zh":"长度","search_zh":"游标卡尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.3","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"游标卡尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 150 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 200 mm","cmc":"10 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"31 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"34 µm"},{"name":"","range":"0 mm do 1000 mm","cmc":"38 µm"}],"reference_cs":"Vnitřní postup IW5.8.3","regulatory_area_cs":"Délka","search_cs":"Posuvná měřidla Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.3","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Posuvná měřidla"},{"_id":"9146b7ebc73524a28c2676ec","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Szczelinomierze","test_object_en":"Feeler gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,02 mm do 3 mm","cmc":"0,9 µm"}],"parameters_en":[{"name":"","range":"0,02 mm to 3 mm","cmc":"0,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza poziomego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a horizontal length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza poziomego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a horizontal length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,02 mm do 3 mm CMC 0,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza poziomego; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.12","norm_bases":["IW5.8.12"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Szczelinomierze Wzorcowanie — Długość\n0,02 mm do 3 mm CMC 0,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza poziomego; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.12 Szczelinomierze Wzorcowanie — Dlugosc\n0,02 mm do 3 mm CMC 0,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza poziomego; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.12","search_en":"Feeler gauges Calibration — Length Internal procedure; Direct method using a horizontal length measuring machine; At permanent location (S) Length Internal procedure Direct method using a horizontal length measuring machine At permanent location (S) Internal procedure IW5.8.12","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":50,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.12","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,02 mm to 3 mm","cmc":"0,9 µm"}],"reference_de":"Internes Verfahren IW5.8.12","regulatory_area_de":"Länge","search_de":"Fühlerlehren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Horizontal-Längenmessgerät; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Horizontal-Längenmessgerät Am festen Standort (S) Internes Verfahren IW5.8.12","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Horizontal-Längenmessgerät; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Horizontal-Längenmessgerät","Am festen Standort (S)"],"test_object_de":"Fühlerlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,02 mm to 3 mm","cmc":"0,9 µm"}],"reference_zh":"内部程序 IW5.8.12","regulatory_area_zh":"长度","search_zh":"塞尺 校准 — 长度 内部程序；使用卧式测长仪的直接法；在固定地点 (S) 长度 内部程序 使用卧式测长仪的直接法 在固定地点 (S) 内部程序 IW5.8.12","technique_zh":"内部程序；使用卧式测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用卧式测长仪的直接法","在固定地点 (S)"],"test_object_zh":"塞尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,02 mm to 3 mm","cmc":"0,9 µm"}],"reference_cs":"Vnitřní postup IW5.8.12","regulatory_area_cs":"Délka","search_cs":"Spároměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím vodorovného délkoměru; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím vodorovného délkoměru Ve stálé lokalitě (S) Vnitřní postup IW5.8.12","technique_cs":"Vnitřní postup; Přímá metoda s použitím vodorovného délkoměru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím vodorovného délkoměru","Ve stálé lokalitě (S)"],"test_object_cs":"Spároměry"},{"_id":"cb05ee71fb5911b522d691fd","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Szczelinomierze","test_object_en":"Feeler gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,02 mm do 3 mm","cmc":"1,6 µm"}],"parameters_en":[{"name":"","range":"0,02 mm to 3 mm","cmc":"1,6 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikrometru cyfrowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a digital micrometer; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem mikrometru cyfrowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a digital micrometer","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,02 mm do 3 mm CMC 1,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikrometru cyfrowego; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.12","norm_bases":["IW5.8.12"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Szczelinomierze Wzorcowanie — Długość\n0,02 mm do 3 mm CMC 1,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikrometru cyfrowego; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.12 Szczelinomierze Wzorcowanie — Dlugosc\n0,02 mm do 3 mm CMC 1,6 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem mikrometru cyfrowego; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.12","search_en":"Feeler gauges Calibration — Length Internal procedure; Direct method using a digital micrometer; At permanent location (S) Length Internal procedure Direct method using a digital micrometer At permanent location (S) Internal procedure IW5.8.12","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":51,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.12","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,02 mm to 3 mm","cmc":"1,6 µm"}],"reference_de":"Internes Verfahren IW5.8.12","regulatory_area_de":"Länge","search_de":"Fühlerlehren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einer digitalen Messschraube; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einer digitalen Messschraube Am festen Standort (S) Internes Verfahren IW5.8.12","technique_de":"Internes Verfahren; Direktes Verfahren mit einer digitalen Messschraube; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einer digitalen Messschraube","Am festen Standort (S)"],"test_object_de":"Fühlerlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,02 mm to 3 mm","cmc":"1,6 µm"}],"reference_zh":"内部程序 IW5.8.12","regulatory_area_zh":"长度","search_zh":"塞尺 校准 — 长度 内部程序；使用数显千分尺的直接法；在固定地点 (S) 长度 内部程序 使用数显千分尺的直接法 在固定地点 (S) 内部程序 IW5.8.12","technique_zh":"内部程序；使用数显千分尺的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用数显千分尺的直接法","在固定地点 (S)"],"test_object_zh":"塞尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,02 mm to 3 mm","cmc":"1,6 µm"}],"reference_cs":"Vnitřní postup IW5.8.12","regulatory_area_cs":"Délka","search_cs":"Spároměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím digitálního mikrometru; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím digitálního mikrometru Ve stálé lokalitě (S) Vnitřní postup IW5.8.12","technique_cs":"Vnitřní postup; Přímá metoda s použitím digitálního mikrometru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím digitálního mikrometru","Ve stálé lokalitě (S)"],"test_object_cs":"Spároměry"},{"_id":"7b766187dbc7f1ab5e92660d","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Szczelinomierze klinowe","test_object_en":"Taper feeler gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 45 mm","cmc":"12 µm"}],"parameters_en":[{"name":"","range":"0 mm to 45 mm","cmc":"12 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 45 mm CMC 12 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.24","norm_bases":["IW5.8.24"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Szczelinomierze klinowe Wzorcowanie — Długość\n0 mm do 45 mm CMC 12 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.24 Szczelinomierze klinowe Wzorcowanie — Dlugosc\n0 mm do 45 mm CMC 12 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.24","search_en":"Taper feeler gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.24","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":52,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.24","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 45 mm","cmc":"12 µm"}],"reference_de":"Internes Verfahren IW5.8.24","regulatory_area_de":"Länge","search_de":"Keilfühlerlehren Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.24","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Keilfühlerlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 45 mm","cmc":"12 µm"}],"reference_zh":"内部程序 IW5.8.24","regulatory_area_zh":"长度","search_zh":"楔形塞尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.24","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"楔形塞尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 45 mm","cmc":"12 µm"}],"reference_cs":"Vnitřní postup IW5.8.24","regulatory_area_cs":"Délka","search_cs":"Klínové spároměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.24","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Klínové spároměry"},{"_id":"1ccecbc8a5edeef7cb0a698c","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Średnicówki czujnikowe","test_object_en":"Dial bore gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"4 mm do 18 mm","cmc":"1,5 µm"},{"name":"","range":"18 mm do 50 mm","cmc":"2,0 µm"},{"name":"","range":"50 mm do 150 mm","cmc":"5,0 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"11 µm"},{"name":"","range":"200 mm do 300 mm","cmc":"15 µm"}],"parameters_en":[{"name":"","range":"4 mm to 18 mm","cmc":"1,5 µm"},{"name":"","range":"18 mm to 50 mm","cmc":"2,0 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"5,0 µm"},{"name":"","range":"150 mm to 200 mm","cmc":"11 µm"},{"name":"","range":"200 mm to 300 mm","cmc":"15 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n4 mm do 18 mm CMC 1,5 µm\n18 mm do 50 mm CMC 2,0 µm\n50 mm do 150 mm CMC 5,0 µm\n150 mm do 200 mm CMC 11 µm\n200 mm do 300 mm CMC 15 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.20","norm_bases":["IW5.8.20"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Średnicówki czujnikowe Wzorcowanie — Długość\nZakres:\n4 mm do 18 mm CMC 1,5 µm\n18 mm do 50 mm CMC 2,0 µm\n50 mm do 150 mm CMC 5,0 µm\n150 mm do 200 mm CMC 11 µm\n200 mm do 300 mm CMC 15 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.20 Srednicowki czujnikowe Wzorcowanie — Dlugosc\nZakres:\n4 mm do 18 mm CMC 1,5 µm\n18 mm do 50 mm CMC 2,0 µm\n50 mm do 150 mm CMC 5,0 µm\n150 mm do 200 mm CMC 11 µm\n200 mm do 300 mm CMC 15 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.20","search_en":"Dial bore gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.20","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":53,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.20","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"4 mm to 18 mm","cmc":"1,5 µm"},{"name":"","range":"18 mm to 50 mm","cmc":"2,0 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"5,0 µm"},{"name":"","range":"150 mm to 200 mm","cmc":"11 µm"},{"name":"","range":"200 mm to 300 mm","cmc":"15 µm"}],"reference_de":"Internes Verfahren IW5.8.20","regulatory_area_de":"Länge","search_de":"Innenfeinmessgeräte Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.20","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Innenfeinmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"4 mm to 18 mm","cmc":"1,5 µm"},{"name":"","range":"18 mm to 50 mm","cmc":"2,0 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"5,0 µm"},{"name":"","range":"150 mm to 200 mm","cmc":"11 µm"},{"name":"","range":"200 mm to 300 mm","cmc":"15 µm"}],"reference_zh":"内部程序 IW5.8.20","regulatory_area_zh":"长度","search_zh":"内径指示表 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.20","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"内径指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"4 mm to 18 mm","cmc":"1,5 µm"},{"name":"","range":"18 mm to 50 mm","cmc":"2,0 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"5,0 µm"},{"name":"","range":"150 mm to 200 mm","cmc":"11 µm"},{"name":"","range":"200 mm to 300 mm","cmc":"15 µm"}],"reference_cs":"Vnitřní postup IW5.8.20","regulatory_area_cs":"Délka","search_cs":"Úchylkoměrné dutinoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.20","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Úchylkoměrné dutinoměry"},{"_id":"8f165cc82009ccaf9c0d25ac","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Średnicówki mikrometryczne dwupunktowe","test_object_en":"Two-point inside micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"50 mm do 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"2,2 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"2,3 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"2,8 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"3,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"4,3 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"5,2 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"5,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"5,8 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"6,1 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"6,3 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"6,3 µm"}],"parameters_en":[{"name":"","range":"50 mm to 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm to 125 mm","cmc":"2,2 µm"},{"name":"","range":"125 mm to 150 mm","cmc":"2,3 µm"},{"name":"","range":"150 mm to 175 mm","cmc":"2,8 µm"},{"name":"","range":"175 mm to 200 mm","cmc":"3,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"4,3 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"5,2 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"5,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"5,8 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"6,1 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"6,3 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"6,3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Trimos Labconcept Premium 500 length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 125 mm CMC 2,2 µm\n125 mm do 150 mm CMC 2,3 µm\n150 mm do 175 mm CMC 2,8 µm\n175 mm do 200 mm CMC 3,5 µm\n200 mm do 225 mm CMC 4,3 µm\n225 mm do 250 mm CMC 5,2 µm\n250 mm do 275 mm CMC 5,5 µm\n275 mm do 300 mm CMC 5,8 µm\n300 mm do 325 mm CMC 6,1 µm\n325 mm do 350 mm CMC 6,3 µm\n350 mm do 375 mm CMC 6,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.25","norm_bases":["IW5.8.25"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Średnicówki mikrometryczne dwupunktowe Wzorcowanie — Długość\nZakres:\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 125 mm CMC 2,2 µm\n125 mm do 150 mm CMC 2,3 µm\n150 mm do 175 mm CMC 2,8 µm\n175 mm do 200 mm CMC 3,5 µm\n200 mm do 225 mm CMC 4,3 µm\n225 mm do 250 mm CMC 5,2 µm\n250 mm do 275 mm CMC 5,5 µm\n275 mm do 300 mm CMC 5,8 µm\n300 mm do 325 mm CMC 6,1 µm\n325 mm do 350 mm CMC 6,3 µm\n350 mm do 375 mm CMC 6,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.25 Srednicowki mikrometryczne dwupunktowe Wzorcowanie — Dlugosc\nZakres:\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 125 mm CMC 2,2 µm\n125 mm do 150 mm CMC 2,3 µm\n150 mm do 175 mm CMC 2,8 µm\n175 mm do 200 mm CMC 3,5 µm\n200 mm do 225 mm CMC 4,3 µm\n225 mm do 250 mm CMC 5,2 µm\n250 mm do 275 mm CMC 5,5 µm\n275 mm do 300 mm CMC 5,8 µm\n300 mm do 325 mm CMC 6,1 µm\n325 mm do 350 mm CMC 6,3 µm\n350 mm do 375 mm CMC 6,3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.25","search_en":"Two-point inside micrometers Calibration — Length Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S) Length Internal procedure Direct method using the Trimos Labconcept Premium 500 length measuring machine At permanent location (S) Internal procedure IW5.8.25","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":54,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.25","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"50 mm bis 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm bis 125 mm","cmc":"2,2 µm"},{"name":"","range":"125 mm bis 150 mm","cmc":"2,3 µm"},{"name":"","range":"150 mm bis 175 mm","cmc":"2,8 µm"},{"name":"","range":"175 mm bis 200 mm","cmc":"3,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"4,3 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"5,2 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"5,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"5,8 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"6,1 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"6,3 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"6,3 µm"}],"reference_de":"Internes Verfahren IW5.8.25","regulatory_area_de":"Länge","search_de":"Zweipunkt-Innenmessschrauben Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 Am festen Standort (S) Internes Verfahren IW5.8.25","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500","Am festen Standort (S)"],"test_object_de":"Zweipunkt-Innenmessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"50 mm 至 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm 至 125 mm","cmc":"2,2 µm"},{"name":"","range":"125 mm 至 150 mm","cmc":"2,3 µm"},{"name":"","range":"150 mm 至 175 mm","cmc":"2,8 µm"},{"name":"","range":"175 mm 至 200 mm","cmc":"3,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"4,3 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"5,2 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"5,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"5,8 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"6,1 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"6,3 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"6,3 µm"}],"reference_zh":"内部程序 IW5.8.25","regulatory_area_zh":"长度","search_zh":"两点式内径千分尺 校准 — 长度 内部程序；使用Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S) 长度 内部程序 使用Trimos Labconcept Premium 500测长仪的直接法 在固定地点 (S) 内部程序 IW5.8.25","technique_zh":"内部程序；使用Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Trimos Labconcept Premium 500测长仪的直接法","在固定地点 (S)"],"test_object_zh":"两点式内径千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"50 mm do 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"2,2 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"2,3 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"2,8 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"3,5 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"4,3 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"5,2 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"5,5 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"5,8 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"6,1 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"6,3 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"6,3 µm"}],"reference_cs":"Vnitřní postup IW5.8.25","regulatory_area_cs":"Délka","search_cs":"Dvoudotekové mikrometrické odpichy Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 Ve stálé lokalitě (S) Vnitřní postup IW5.8.25","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500","Ve stálé lokalitě (S)"],"test_object_cs":"Dvoudotekové mikrometrické odpichy"},{"_id":"796b030cb1384bfcbf8afb51","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Średnicówki trójpunktowe mikrometryczne\nŚrednicówki trójpunktowe czujnikowe","test_object_en":"Three-point inside micrometers\nThree-point dial bore gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"3,5 mm do 12 mm","cmc":"1,9 µm"},{"name":"","range":"12 mm do 35 mm","cmc":"2,0 µm"},{"name":"","range":"35 mm do 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 80 mm","cmc":"2,3 µm"},{"name":"","range":"80 mm do 100 mm","cmc":"2,8 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"2,9 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"3,3 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"3,5 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"4,6 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"4,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"5,3 µm"}],"parameters_en":[{"name":"","range":"3,5 mm do 12 mm","cmc":"1,9 µm"},{"name":"","range":"12 mm do 35 mm","cmc":"2,0 µm"},{"name":"","range":"35 mm do 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 80 mm","cmc":"2,3 µm"},{"name":"","range":"80 mm do 100 mm","cmc":"2,8 µm"},{"name":"","range":"100 mm to 125 mm","cmc":"2,9 µm"},{"name":"","range":"125 mm to 150 mm","cmc":"3,3 µm"},{"name":"","range":"150 mm to 175 mm","cmc":"3,5 µm"},{"name":"","range":"175 mm to 200 mm","cmc":"4,6 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"4,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"5,3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem pierścieni wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using setting rings; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem pierścieni wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using setting rings","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n3,5 mm do 12 mm CMC 1,9 µm\n12 mm do 35 mm CMC 2,0 µm\n35 mm do 50 mm CMC 2,1 µm\n50 mm do 80 mm CMC 2,3 µm\n80 mm do 100 mm CMC 2,8 µm\n100 mm do 125 mm CMC 2,9 µm\n125 mm do 150 mm CMC 3,3 µm\n150 mm do 175 mm CMC 3,5 µm\n175 mm do 200 mm CMC 4,6 µm\n200 mm do 250 mm CMC 4,8 µm\n250 mm do 275 mm CMC 4,9 µm\n275 mm do 300 mm CMC 5,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem pierścieni wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.15","norm_bases":["IW5.8.15"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Średnicówki trójpunktowe mikrometryczne\nŚrednicówki trójpunktowe czujnikowe Wzorcowanie — Długość\nZakres:\n3,5 mm do 12 mm CMC 1,9 µm\n12 mm do 35 mm CMC 2,0 µm\n35 mm do 50 mm CMC 2,1 µm\n50 mm do 80 mm CMC 2,3 µm\n80 mm do 100 mm CMC 2,8 µm\n100 mm do 125 mm CMC 2,9 µm\n125 mm do 150 mm CMC 3,3 µm\n150 mm do 175 mm CMC 3,5 µm\n175 mm do 200 mm CMC 4,6 µm\n200 mm do 250 mm CMC 4,8 µm\n250 mm do 275 mm CMC 4,9 µm\n275 mm do 300 mm CMC 5,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem pierścieni wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.15 Srednicowki trojpunktowe mikrometryczne\nSrednicowki trojpunktowe czujnikowe Wzorcowanie — Dlugosc\nZakres:\n3,5 mm do 12 mm CMC 1,9 µm\n12 mm do 35 mm CMC 2,0 µm\n35 mm do 50 mm CMC 2,1 µm\n50 mm do 80 mm CMC 2,3 µm\n80 mm do 100 mm CMC 2,8 µm\n100 mm do 125 mm CMC 2,9 µm\n125 mm do 150 mm CMC 3,3 µm\n150 mm do 175 mm CMC 3,5 µm\n175 mm do 200 mm CMC 4,6 µm\n200 mm do 250 mm CMC 4,8 µm\n250 mm do 275 mm CMC 4,9 µm\n275 mm do 300 mm CMC 5,3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem pierscieni wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.15","search_en":"Three-point inside micrometers Three-point dial bore gauges Calibration — Length Internal procedure; Direct method using setting rings; At permanent location (S) Length Internal procedure Direct method using setting rings At permanent location (S) Internal procedure IW5.8.15","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":55,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.15","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"3,5 mm do 12 mm","cmc":"1,9 µm"},{"name":"","range":"12 mm do 35 mm","cmc":"2,0 µm"},{"name":"","range":"35 mm do 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 80 mm","cmc":"2,3 µm"},{"name":"","range":"80 mm do 100 mm","cmc":"2,8 µm"},{"name":"","range":"100 mm bis 125 mm","cmc":"2,9 µm"},{"name":"","range":"125 mm bis 150 mm","cmc":"3,3 µm"},{"name":"","range":"150 mm bis 175 mm","cmc":"3,5 µm"},{"name":"","range":"175 mm bis 200 mm","cmc":"4,6 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"4,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"5,3 µm"}],"reference_de":"Internes Verfahren IW5.8.15","regulatory_area_de":"Länge","search_de":"Dreipunkt-Innenmessschrauben Dreipunkt-Innenfeinmessgeräte Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Einstellringen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Einstellringen Am festen Standort (S) Internes Verfahren IW5.8.15","technique_de":"Internes Verfahren; Direktes Verfahren mit Einstellringen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Einstellringen","Am festen Standort (S)"],"test_object_de":"Dreipunkt-Innenmessschrauben\nDreipunkt-Innenfeinmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"3,5 mm do 12 mm","cmc":"1,9 µm"},{"name":"","range":"12 mm do 35 mm","cmc":"2,0 µm"},{"name":"","range":"35 mm do 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 80 mm","cmc":"2,3 µm"},{"name":"","range":"80 mm do 100 mm","cmc":"2,8 µm"},{"name":"","range":"100 mm 至 125 mm","cmc":"2,9 µm"},{"name":"","range":"125 mm 至 150 mm","cmc":"3,3 µm"},{"name":"","range":"150 mm 至 175 mm","cmc":"3,5 µm"},{"name":"","range":"175 mm 至 200 mm","cmc":"4,6 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"4,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"5,3 µm"}],"reference_zh":"内部程序 IW5.8.15","regulatory_area_zh":"长度","search_zh":"三点式内径千分尺 三点式内径指示表 校准 — 长度 内部程序；使用校对环规的直接法；在固定地点 (S) 长度 内部程序 使用校对环规的直接法 在固定地点 (S) 内部程序 IW5.8.15","technique_zh":"内部程序；使用校对环规的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用校对环规的直接法","在固定地点 (S)"],"test_object_zh":"三点式内径千分尺\n三点式内径指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"3,5 mm do 12 mm","cmc":"1,9 µm"},{"name":"","range":"12 mm do 35 mm","cmc":"2,0 µm"},{"name":"","range":"35 mm do 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 80 mm","cmc":"2,3 µm"},{"name":"","range":"80 mm do 100 mm","cmc":"2,8 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"2,9 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"3,3 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"3,5 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"4,6 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"4,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"5,3 µm"}],"reference_cs":"Vnitřní postup IW5.8.15","regulatory_area_cs":"Délka","search_cs":"Třídotekové mikrometrické dutinoměry Třídotekové dutinoměry s úchylkoměrem Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím nastavovacích kroužků; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím nastavovacích kroužků Ve stálé lokalitě (S) Vnitřní postup IW5.8.15","technique_cs":"Vnitřní postup; Přímá metoda s použitím nastavovacích kroužků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím nastavovacích kroužků","Ve stálé lokalitě (S)"],"test_object_cs":"Třídotekové mikrometrické dutinoměry\nTřídotekové dutinoměry s úchylkoměrem"},{"_id":"08f0d3e4c24aff92008da9e3","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Transametry","test_object_en":"Indicating snap gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,0 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,2 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,3 µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm to 50 mm","cmc":"1,0 µm"},{"name":"","range":"50 mm to 75 mm","cmc":"1,2 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"1,3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 0,9 µm\n25 mm do 50 mm CMC 1,0 µm\n50 mm do 75 mm CMC 1,2 µm\n75 mm do 100 mm CMC 1,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.5","norm_bases":["IW5.8.5"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Transametry Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 0,9 µm\n25 mm do 50 mm CMC 1,0 µm\n50 mm do 75 mm CMC 1,2 µm\n75 mm do 100 mm CMC 1,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.5 Transametry Wzorcowanie — Dlugosc\nZakres:\n0 mm do 25 mm CMC 0,9 µm\n25 mm do 50 mm CMC 1,0 µm\n50 mm do 75 mm CMC 1,2 µm\n75 mm do 100 mm CMC 1,3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.5","search_en":"Indicating snap gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.5","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":56,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.5","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm bis 50 mm","cmc":"1,0 µm"},{"name":"","range":"50 mm bis 75 mm","cmc":"1,2 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"1,3 µm"}],"reference_de":"Internes Verfahren IW5.8.5","regulatory_area_de":"Länge","search_de":"Transameter Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.5","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Transameter","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm 至 50 mm","cmc":"1,0 µm"},{"name":"","range":"50 mm 至 75 mm","cmc":"1,2 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"1,3 µm"}],"reference_zh":"内部程序 IW5.8.5","regulatory_area_zh":"长度","search_zh":"Transametr 量仪 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.5","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"Transametr 量仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,0 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,2 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,3 µm"}],"reference_cs":"Vnitřní postup IW5.8.5","regulatory_area_cs":"Délka","search_cs":"Pasametry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.5","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Pasametry"},{"_id":"68626a9cdf5f3bedeafe49a5","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Wałeczki pomiarowe","test_object_en":"Measuring rollers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 20 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 20 mm","cmc":"0,5 µm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz czujnika typu MOP 02/20; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparison method using gauge blocks and a MOP 02/20 type probe; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem płytek wzorcowych oraz czujnika typu MOP 02/20","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparison method using gauge blocks and a MOP 02/20 type probe","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 20 mm CMC 0,5 µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz czujnika typu MOP 02/20; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.26","norm_bases":["IW5.8.26"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wałeczki pomiarowe Wzorcowanie — Długość\n0 mm do 20 mm CMC 0,5 µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz czujnika typu MOP 02/20; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.26 Waleczki pomiarowe Wzorcowanie — Dlugosc\n0 mm do 20 mm CMC 0,5 µm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem plytek wzorcowych oraz czujnika typu MOP 02/20; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.26","search_en":"Measuring rollers Calibration — Length Internal procedure; Comparison method using gauge blocks and a MOP 02/20 type probe; At permanent location (S) Length Internal procedure Comparison method using gauge blocks and a MOP 02/20 type probe At permanent location (S) Internal procedure IW5.8.26","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":57,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.26","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 20 mm","cmc":"0,5 µm"}],"reference_de":"Internes Verfahren IW5.8.26","regulatory_area_de":"Länge","search_de":"Messrollen Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit Parallelendmaßen und einem Messtaster Typ MOP 02/20; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit Parallelendmaßen und einem Messtaster Typ MOP 02/20 Am festen Standort (S) Internes Verfahren IW5.8.26","technique_de":"Internes Verfahren; Vergleichsverfahren mit Parallelendmaßen und einem Messtaster Typ MOP 02/20; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit Parallelendmaßen und einem Messtaster Typ MOP 02/20","Am festen Standort (S)"],"test_object_de":"Messrollen","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 20 mm","cmc":"0,5 µm"}],"reference_zh":"内部程序 IW5.8.26","regulatory_area_zh":"长度","search_zh":"测量用量棒 校准 — 长度 内部程序；使用量块和MOP 02/20型测头的比较法；在固定地点 (S) 长度 内部程序 使用量块和MOP 02/20型测头的比较法 在固定地点 (S) 内部程序 IW5.8.26","technique_zh":"内部程序；使用量块和MOP 02/20型测头的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用量块和MOP 02/20型测头的比较法","在固定地点 (S)"],"test_object_zh":"测量用量棒","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 20 mm","cmc":"0,5 µm"}],"reference_cs":"Vnitřní postup IW5.8.26","regulatory_area_cs":"Délka","search_cs":"Měřicí válečky Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím koncových měrek a snímače typu MOP 02/20; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím koncových měrek a snímače typu MOP 02/20 Ve stálé lokalitě (S) Vnitřní postup IW5.8.26","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím koncových měrek a snímače typu MOP 02/20; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím koncových měrek a snímače typu MOP 02/20","Ve stálé lokalitě (S)"],"test_object_cs":"Měřicí válečky"},{"_id":"006ea22ab9a452d4a038835e","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Wałeczki pomiarowe","test_object_en":"Measuring rollers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 30 mm","cmc":"1,0 µm"}],"parameters_en":[{"name":"","range":"0 mm to 30 mm","cmc":"1,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Trimos Labconcept Premium 500 length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 30 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.26","norm_bases":["IW5.8.26"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wałeczki pomiarowe Wzorcowanie — Długość\n0 mm do 30 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.26 Waleczki pomiarowe Wzorcowanie — Dlugosc\n0 mm do 30 mm CMC 1,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.26","search_en":"Measuring rollers Calibration — Length Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S) Length Internal procedure Direct method using the Trimos Labconcept Premium 500 length measuring machine At permanent location (S) Internal procedure IW5.8.26","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":58,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.26","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 30 mm","cmc":"1,0 µm"}],"reference_de":"Internes Verfahren IW5.8.26","regulatory_area_de":"Länge","search_de":"Messrollen Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 Am festen Standort (S) Internes Verfahren IW5.8.26","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500","Am festen Standort (S)"],"test_object_de":"Messrollen","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 30 mm","cmc":"1,0 µm"}],"reference_zh":"内部程序 IW5.8.26","regulatory_area_zh":"长度","search_zh":"测量用量棒 校准 — 长度 内部程序；使用Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S) 长度 内部程序 使用Trimos Labconcept Premium 500测长仪的直接法 在固定地点 (S) 内部程序 IW5.8.26","technique_zh":"内部程序；使用Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Trimos Labconcept Premium 500测长仪的直接法","在固定地点 (S)"],"test_object_zh":"测量用量棒","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 30 mm","cmc":"1,0 µm"}],"reference_cs":"Vnitřní postup IW5.8.26","regulatory_area_cs":"Délka","search_cs":"Měřicí válečky Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 Ve stálé lokalitě (S) Vnitřní postup IW5.8.26","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500","Ve stálé lokalitě (S)"],"test_object_cs":"Měřicí válečky"},{"_id":"d813b42bf57ab567e6664230","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Wysokościomierze cyfrowe o rozdzielczości","test_object_en":"Digital height gauges with resolution","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- 0,01 mm","range":"0 mm do 600mm","cmc":"Q[5,9; 8,3∙L] µm"},{"name":"- 0,005 mm","range":"0 mm do 600mm","cmc":"Q[3,1; 8,3∙L] µm"},{"name":"- 0,001 mm","range":"0 mm do 600mm","cmc":"Q[0,7; 8,3∙L] µm"}],"parameters_en":[{"name":"- 0,01 mm","range":"0 mm to 600mm","cmc":"Q[5,9; 8,3∙L] µm"},{"name":"- 0,005 mm","range":"0 mm to 600mm","cmc":"Q[3,1; 8,3∙L] µm"},{"name":"- 0,001 mm","range":"0 mm to 600mm","cmc":"Q[0,7; 8,3∙L] µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- 0,01 mm 0 mm do 600mm CMC Q[5,9; 8,3∙L] µm\n- 0,005 mm 0 mm do 600mm CMC Q[3,1; 8,3∙L] µm\n- 0,001 mm 0 mm do 600mm CMC Q[0,7; 8,3∙L] µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.50","norm_bases":["IW5.8.50"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L – wielkość mierzona (m)","note_en":"L – measured quantity (m)","search_text":"Wysokościomierze cyfrowe o rozdzielczości Wzorcowanie — Długość\nZakres:\n- 0,01 mm 0 mm do 600mm CMC Q[5,9; 8,3∙L] µm\n- 0,005 mm 0 mm do 600mm CMC Q[3,1; 8,3∙L] µm\n- 0,001 mm 0 mm do 600mm CMC Q[0,7; 8,3∙L] µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.50 Wysokosciomierze cyfrowe o rozdzielczosci Wzorcowanie — Dlugosc\nZakres:\n- 0,01 mm 0 mm do 600mm CMC Q[5,9; 8,3∙L] µm\n- 0,005 mm 0 mm do 600mm CMC Q[3,1; 8,3∙L] µm\n- 0,001 mm 0 mm do 600mm CMC Q[0,7; 8,3∙L] µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.50","search_en":"Digital height gauges with resolution Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) - 0,01 mm - 0,005 mm - 0,001 mm Internal procedure IW5.8.50","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":59,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.50","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- 0,01 mm","range":"0 mm to 600mm","cmc":"Q[5,9; 8,3∙L] µm"},{"name":"- 0,005 mm","range":"0 mm to 600mm","cmc":"Q[3,1; 8,3∙L] µm"},{"name":"- 0,001 mm","range":"0 mm to 600mm","cmc":"Q[0,7; 8,3∙L] µm"}],"reference_de":"Internes Verfahren IW5.8.50","regulatory_area_de":"Länge","search_de":"Digitale Höhenmessgeräte mit Auflösung Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) - 0,01 mm - 0,005 mm - 0,001 mm Internes Verfahren IW5.8.50","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Digitale Höhenmessgeräte mit Auflösung","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 0,01 mm","range":"0 mm to 600mm","cmc":"Q[5,9; 8,3∙L] µm"},{"name":"- 0,005 mm","range":"0 mm to 600mm","cmc":"Q[3,1; 8,3∙L] µm"},{"name":"- 0,001 mm","range":"0 mm to 600mm","cmc":"Q[0,7; 8,3∙L] µm"}],"reference_zh":"内部程序 IW5.8.50","regulatory_area_zh":"长度","search_zh":"分辨力为下列值的数显高度尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) - 0,01 mm - 0,005 mm - 0,001 mm 内部程序 IW5.8.50","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"分辨力为下列值的数显高度尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- 0,01 mm","range":"0 mm to 600mm","cmc":"Q[5,9; 8,3∙L] µm"},{"name":"- 0,005 mm","range":"0 mm to 600mm","cmc":"Q[3,1; 8,3∙L] µm"},{"name":"- 0,001 mm","range":"0 mm to 600mm","cmc":"Q[0,7; 8,3∙L] µm"}],"reference_cs":"Vnitřní postup IW5.8.50","regulatory_area_cs":"Délka","search_cs":"Digitální výškoměry s rozlišením Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) - 0,01 mm - 0,005 mm - 0,001 mm Vnitřní postup IW5.8.50","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální výškoměry s rozlišením"},{"_id":"3f94ce33d90dc01f9cdb931e","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Wysokościomierze suwmiarkowe","test_object_en":"Vernier height gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"34 µm"},{"name":"","range":"0 mm do 1000 mm","cmc":"38 µm"}],"parameters_en":[{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm to 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"34 µm"},{"name":"","range":"0 mm to 1000 mm","cmc":"38 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 300 mm CMC 12 µm\n0 mm do 500 mm CMC 17 µm\n0 mm do 600 mm CMC 20 µm\n0 mm do 800 mm CMC 34 µm\n0 mm do 1000 mm CMC 38 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.3","norm_bases":["IW5.8.3"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wysokościomierze suwmiarkowe Wzorcowanie — Długość\nZakres:\n0 mm do 300 mm CMC 12 µm\n0 mm do 500 mm CMC 17 µm\n0 mm do 600 mm CMC 20 µm\n0 mm do 800 mm CMC 34 µm\n0 mm do 1000 mm CMC 38 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.3 Wysokosciomierze suwmiarkowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 300 mm CMC 12 µm\n0 mm do 500 mm CMC 17 µm\n0 mm do 600 mm CMC 20 µm\n0 mm do 800 mm CMC 34 µm\n0 mm do 1000 mm CMC 38 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.3","search_en":"Vernier height gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.3","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":60,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.3","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm bis 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"34 µm"},{"name":"","range":"0 mm bis 1000 mm","cmc":"38 µm"}],"reference_de":"Internes Verfahren IW5.8.3","regulatory_area_de":"Länge","search_de":"Höhenmessschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.3","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Höhenmessschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm 至 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"34 µm"},{"name":"","range":"0 mm 至 1000 mm","cmc":"38 µm"}],"reference_zh":"内部程序 IW5.8.3","regulatory_area_zh":"长度","search_zh":"游标高度尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.3","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"游标高度尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 300 mm","cmc":"12 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"34 µm"},{"name":"","range":"0 mm do 1000 mm","cmc":"38 µm"}],"reference_cs":"Vnitřní postup IW5.8.3","regulatory_area_cs":"Délka","search_cs":"Posuvné výškoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.3","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Posuvné výškoměry"},{"_id":"e0868313ae877ef01502d230","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Wzorce nastawcze do wymiarów wewnętrznych","test_object_en":"Setting standards for internal dimensions","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"do 100 mm","cmc":"2,0 µm"}],"parameters_en":[{"name":"","range":"up to 100 mm","cmc":"2,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\ndo 100 mm CMC 2,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.27","norm_bases":["IW5.8.27"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce nastawcze do wymiarów wewnętrznych Wzorcowanie — Długość\ndo 100 mm CMC 2,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500 wyposażonego w kabłąki; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.27 Wzorce nastawcze do wymiarow wewnetrznych Wzorcowanie — Dlugosc\ndo 100 mm CMC 2,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500 wyposazonego w kablaki; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.27","search_en":"Setting standards for internal dimensions Calibration — Length Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms; At permanent location (S) Length Internal procedure Direct method using the Trimos Labconcept Premium 500 length measuring machine fitted with contact arms At permanent location (S) Internal procedure IW5.8.27","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":61,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.27","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"bis 100 mm","cmc":"2,0 µm"}],"reference_de":"Internes Verfahren IW5.8.27","regulatory_area_de":"Länge","search_de":"Einstellnormale für Innenmaße Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln Am festen Standort (S) Internes Verfahren IW5.8.27","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 mit Messbügeln","Am festen Standort (S)"],"test_object_de":"Einstellnormale für Innenmaße","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"至 100 mm","cmc":"2,0 µm"}],"reference_zh":"内部程序 IW5.8.27","regulatory_area_zh":"长度","search_zh":"内尺寸校对标准器 校准 — 长度 内部程序；使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S) 长度 内部程序 使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法 在固定地点 (S) 内部程序 IW5.8.27","technique_zh":"内部程序；使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用配测量臂的Trimos Labconcept Premium 500测长仪的直接法","在固定地点 (S)"],"test_object_zh":"内尺寸校对标准器","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"do 100 mm","cmc":"2,0 µm"}],"reference_cs":"Vnitřní postup IW5.8.27","regulatory_area_cs":"Délka","search_cs":"Nastavovací etalony pro vnitřní rozměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny Ve stálé lokalitě (S) Vnitřní postup IW5.8.27","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 vybaveného třmeny","Ve stálé lokalitě (S)"],"test_object_cs":"Nastavovací etalony pro vnitřní rozměry"},{"_id":"59c7e2e8299b88c3e46a1d2b","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Wzorce nastawcze wymiarów zewnętrznych","test_object_en":"Setting standards for external dimensions","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,0 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,2 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"1,5 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"1,6 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"2,1 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"2,2 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"2,3 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"2,4 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"2,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"3,0 µm"}],"parameters_en":[{"name":"","range":"25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm to 50 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm to 75 mm","cmc":"1,0 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"1,2 µm"},{"name":"","range":"100 mm to 125 mm","cmc":"1,5 µm"},{"name":"","range":"125 mm to 150 mm","cmc":"1,6 µm"},{"name":"","range":"150 mm to 175 mm","cmc":"2,1 µm"},{"name":"","range":"175 mm to 200 mm","cmc":"2,2 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"2,3 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"2,4 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"2,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"3,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using the Trimos Labconcept Premium 500 length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n25 mm CMC 0,9 µm\n25 mm do 50 mm CMC 0,9 µm\n50 mm do 75 mm CMC 1,0 µm\n75 mm do 100 mm CMC 1,2 µm\n100 mm do 125 mm CMC 1,5 µm\n125 mm do 150 mm CMC 1,6 µm\n150 mm do 175 mm CMC 2,1 µm\n175 mm do 200 mm CMC 2,2 µm\n200 mm do 225 mm CMC 2,3 µm\n225 mm do 250 mm CMC 2,4 µm\n250 mm do 275 mm CMC 2,9 µm\n275 mm do 300 mm CMC 3,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.9","norm_bases":["IW5.8.9"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce nastawcze wymiarów zewnętrznych Wzorcowanie — Długość\nZakres:\n25 mm CMC 0,9 µm\n25 mm do 50 mm CMC 0,9 µm\n50 mm do 75 mm CMC 1,0 µm\n75 mm do 100 mm CMC 1,2 µm\n100 mm do 125 mm CMC 1,5 µm\n125 mm do 150 mm CMC 1,6 µm\n150 mm do 175 mm CMC 2,1 µm\n175 mm do 200 mm CMC 2,2 µm\n200 mm do 225 mm CMC 2,3 µm\n225 mm do 250 mm CMC 2,4 µm\n250 mm do 275 mm CMC 2,9 µm\n275 mm do 300 mm CMC 3,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza Trimos Labconcept Premium 500; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.9 Wzorce nastawcze wymiarow zewnetrznych Wzorcowanie — Dlugosc\nZakres:\n25 mm CMC 0,9 µm\n25 mm do 50 mm CMC 0,9 µm\n50 mm do 75 mm CMC 1,0 µm\n75 mm do 100 mm CMC 1,2 µm\n100 mm do 125 mm CMC 1,5 µm\n125 mm do 150 mm CMC 1,6 µm\n150 mm do 175 mm CMC 2,1 µm\n175 mm do 200 mm CMC 2,2 µm\n200 mm do 225 mm CMC 2,3 µm\n225 mm do 250 mm CMC 2,4 µm\n250 mm do 275 mm CMC 2,9 µm\n275 mm do 300 mm CMC 3,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza Trimos Labconcept Premium 500; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.9","search_en":"Setting standards for external dimensions Calibration — Length Internal procedure; Direct method using the Trimos Labconcept Premium 500 length measuring machine; At permanent location (S) Length Internal procedure Direct method using the Trimos Labconcept Premium 500 length measuring machine At permanent location (S) Internal procedure IW5.8.9","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":62,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.9","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm bis 50 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm bis 75 mm","cmc":"1,0 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"1,2 µm"},{"name":"","range":"100 mm bis 125 mm","cmc":"1,5 µm"},{"name":"","range":"125 mm bis 150 mm","cmc":"1,6 µm"},{"name":"","range":"150 mm bis 175 mm","cmc":"2,1 µm"},{"name":"","range":"175 mm bis 200 mm","cmc":"2,2 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"2,3 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"2,4 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"2,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"3,0 µm"}],"reference_de":"Internes Verfahren IW5.8.9","regulatory_area_de":"Länge","search_de":"Einstellnormale für Außenmaße Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500 Am festen Standort (S) Internes Verfahren IW5.8.9","technique_de":"Internes Verfahren; Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit dem Längenmessgerät Trimos Labconcept Premium 500","Am festen Standort (S)"],"test_object_de":"Einstellnormale für Außenmaße","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm 至 50 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm 至 75 mm","cmc":"1,0 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"1,2 µm"},{"name":"","range":"100 mm 至 125 mm","cmc":"1,5 µm"},{"name":"","range":"125 mm 至 150 mm","cmc":"1,6 µm"},{"name":"","range":"150 mm 至 175 mm","cmc":"2,1 µm"},{"name":"","range":"175 mm 至 200 mm","cmc":"2,2 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"2,3 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"2,4 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"2,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"3,0 µm"}],"reference_zh":"内部程序 IW5.8.9","regulatory_area_zh":"长度","search_zh":"外尺寸校对标准器 校准 — 长度 内部程序；使用Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S) 长度 内部程序 使用Trimos Labconcept Premium 500测长仪的直接法 在固定地点 (S) 内部程序 IW5.8.9","technique_zh":"内部程序；使用Trimos Labconcept Premium 500测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Trimos Labconcept Premium 500测长仪的直接法","在固定地点 (S)"],"test_object_zh":"外尺寸校对标准器","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,0 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,2 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"1,5 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"1,6 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"2,1 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"2,2 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"2,3 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"2,4 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"2,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"3,0 µm"}],"reference_cs":"Vnitřní postup IW5.8.9","regulatory_area_cs":"Délka","search_cs":"Nastavovací etalony vnějších rozměrů Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500 Ve stálé lokalitě (S) Vnitřní postup IW5.8.9","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru Trimos Labconcept Premium 500","Ve stálé lokalitě (S)"],"test_object_cs":"Nastavovací etalony vnějších rozměrů"},{"_id":"780816c7c72e2609fe0fa4ba","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Kątomierze cyfrowe","test_object_en":"Digital protractors","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0° do 360°","cmc":"3,6’"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"3,6’"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using angle gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using angle gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0° do 360° CMC 3,6’\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.28","norm_bases":["IW5.8.28"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątomierze cyfrowe Wzorcowanie — Kąt\n0° do 360° CMC 3,6’\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.28 Katomierze cyfrowe Wzorcowanie — Kat\n0° do 360° CMC 3,6’\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych katowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.28","search_en":"Digital protractors Calibration — Angle Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Angle Internal procedure Direct method using angle gauge blocks At permanent location (S) Internal procedure IW5.8.28","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":63,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.28","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0° bis 360°","cmc":"3,6’"}],"reference_de":"Internes Verfahren IW5.8.28","regulatory_area_de":"Winkel","search_de":"Digitale Winkelmesser Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit Winkelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.28","technique_de":"Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Winkelendmaßen","Am festen Standort (S)"],"test_object_de":"Digitale Winkelmesser","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"3,6’"}],"reference_zh":"内部程序 IW5.8.28","regulatory_area_zh":"角度","search_zh":"数显角度尺 校准 — 角度 内部程序；使用角度量块的直接法；在固定地点 (S) 角度 内部程序 使用角度量块的直接法 在固定地点 (S) 内部程序 IW5.8.28","technique_zh":"内部程序；使用角度量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用角度量块的直接法","在固定地点 (S)"],"test_object_zh":"数显角度尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0° do 360°","cmc":"3,6’"}],"reference_cs":"Vnitřní postup IW5.8.28","regulatory_area_cs":"Úhel","search_cs":"Digitální úhloměry Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím úhlových koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.28","technique_cs":"Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím úhlových koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úhloměry"},{"_id":"bab383e233f6e6b18c509584","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Kątomierze traserskie","test_object_en":"Marking-out protractors","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0° do 180°","cmc":"0,2°"}],"parameters_en":[{"name":"","range":"0° to 180°","cmc":"0,2°"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using angle gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using angle gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0° do 180° CMC 0,2°\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.28","norm_bases":["IW5.8.28"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątomierze traserskie Wzorcowanie — Kąt\n0° do 180° CMC 0,2°\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.28 Katomierze traserskie Wzorcowanie — Kat\n0° do 180° CMC 0,2°\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych katowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.28","search_en":"Marking-out protractors Calibration — Angle Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Angle Internal procedure Direct method using angle gauge blocks At permanent location (S) Internal procedure IW5.8.28","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":64,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.28","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0° to 180°","cmc":"0,2°"}],"reference_de":"Internes Verfahren IW5.8.28","regulatory_area_de":"Winkel","search_de":"Anreißwinkelmesser Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit Winkelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.28","technique_de":"Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Winkelendmaßen","Am festen Standort (S)"],"test_object_de":"Anreißwinkelmesser","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0° to 180°","cmc":"0,2°"}],"reference_zh":"内部程序 IW5.8.28","regulatory_area_zh":"角度","search_zh":"划线角度尺 校准 — 角度 内部程序；使用角度量块的直接法；在固定地点 (S) 角度 内部程序 使用角度量块的直接法 在固定地点 (S) 内部程序 IW5.8.28","technique_zh":"内部程序；使用角度量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用角度量块的直接法","在固定地点 (S)"],"test_object_zh":"划线角度尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0° to 180°","cmc":"0,2°"}],"reference_cs":"Vnitřní postup IW5.8.28","regulatory_area_cs":"Úhel","search_cs":"Rýsovací úhloměry Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím úhlových koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.28","technique_cs":"Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím úhlových koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Rýsovací úhloměry"},{"_id":"515941f12d25538c242b84d5","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Kątomierze uniwersalne","test_object_en":"Universal bevel protractors","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"4 x 90°","cmc":"3,6’"}],"parameters_en":[{"name":"","range":"4 x 90°","cmc":"3,6’"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using angle gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using angle gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n4 x 90° CMC 3,6’\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.28","norm_bases":["IW5.8.28"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątomierze uniwersalne Wzorcowanie — Kąt\n4 x 90° CMC 3,6’\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.28 Katomierze uniwersalne Wzorcowanie — Kat\n4 x 90° CMC 3,6’\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych katowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.28","search_en":"Universal bevel protractors Calibration — Angle Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Angle Internal procedure Direct method using angle gauge blocks At permanent location (S) Internal procedure IW5.8.28","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":65,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.28","methodology_de":"Kalibrierung — Winkel","reference_de":"Internes Verfahren IW5.8.28","regulatory_area_de":"Winkel","search_de":"Universalwinkelmesser Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit Winkelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.28","technique_de":"Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Winkelendmaßen","Am festen Standort (S)"],"test_object_de":"Universalwinkelmesser","methodology_zh":"校准 — 角度","reference_zh":"内部程序 IW5.8.28","regulatory_area_zh":"角度","search_zh":"万能角度尺 校准 — 角度 内部程序；使用角度量块的直接法；在固定地点 (S) 角度 内部程序 使用角度量块的直接法 在固定地点 (S) 内部程序 IW5.8.28","technique_zh":"内部程序；使用角度量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用角度量块的直接法","在固定地点 (S)"],"test_object_zh":"万能角度尺","methodology_cs":"Kalibrace — Úhel","reference_cs":"Vnitřní postup IW5.8.28","regulatory_area_cs":"Úhel","search_cs":"Univerzální úhloměry Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím úhlových koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.28","technique_cs":"Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím úhlových koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Univerzální úhloměry"},{"_id":"7236077e2cd8cfb5bd335e26","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Kątowniki 90° dwuramienne","test_object_en":"90° try squares","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"długość dłuższego ramienia do 315 mm","cmc":"5,0 µm"}],"parameters_en":[{"name":"","range":"longer arm length up to 315 mm","cmc":"5,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz kątownika walcowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks and a cylindrical square; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz kątownika walcowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks and a cylindrical square","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\ndługość dłuższego ramienia do 315 mm CMC 5,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz kątownika walcowego; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.29","norm_bases":["IW5.8.29"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątowniki 90° dwuramienne Wzorcowanie — Kąt\ndługość dłuższego ramienia do 315 mm CMC 5,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz kątownika walcowego; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.29 Katowniki 90° dwuramienne Wzorcowanie — Kat\ndlugosc dluzszego ramienia do 315 mm CMC 5,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych oraz katownika walcowego; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.29","search_en":"90° try squares Calibration — Angle Internal procedure; Direct method using gauge blocks and a cylindrical square; At permanent location (S) Angle Internal procedure Direct method using gauge blocks and a cylindrical square At permanent location (S) Internal procedure IW5.8.29","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":66,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.29","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"longer arm length up to 315 mm","cmc":"5,0 µm"}],"reference_de":"Internes Verfahren IW5.8.29","regulatory_area_de":"Winkel","search_de":"Zweischenklige 90°-Anschlagwinkel Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit Parallelendmaßen und einem Zylinderwinkel; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit Parallelendmaßen und einem Zylinderwinkel Am festen Standort (S) Internes Verfahren IW5.8.29","technique_de":"Internes Verfahren; Direktes Verfahren mit Parallelendmaßen und einem Zylinderwinkel; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen und einem Zylinderwinkel","Am festen Standort (S)"],"test_object_de":"Zweischenklige 90°-Anschlagwinkel","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"longer arm length up to 315 mm","cmc":"5,0 µm"}],"reference_zh":"内部程序 IW5.8.29","regulatory_area_zh":"角度","search_zh":"90° 宽座直角尺 校准 — 角度 内部程序；使用量块和圆柱角尺的直接法；在固定地点 (S) 角度 内部程序 使用量块和圆柱角尺的直接法 在固定地点 (S) 内部程序 IW5.8.29","technique_zh":"内部程序；使用量块和圆柱角尺的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块和圆柱角尺的直接法","在固定地点 (S)"],"test_object_zh":"90° 宽座直角尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"longer arm length up to 315 mm","cmc":"5,0 µm"}],"reference_cs":"Vnitřní postup IW5.8.29","regulatory_area_cs":"Úhel","search_cs":"Dvouramenné úhelníky 90° Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím koncových měrek a válcového úhelníku; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím koncových měrek a válcového úhelníku Ve stálé lokalitě (S) Vnitřní postup IW5.8.29","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek a válcového úhelníku; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek a válcového úhelníku","Ve stálé lokalitě (S)"],"test_object_cs":"Dvouramenné úhelníky 90°"},{"_id":"50cae6679f15c46f9aaa7027","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Poziomnice budowlane","test_object_en":"Builder's spirit levels","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"- błąd ustawienia wskazania zerowego","range":"0 mm do 300 mm","cmc":"0,2 mm"}],"parameters_en":[{"name":"- zero setting error","range":"0 mm to 300 mm","cmc":"0,2 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płyty pomiarowej i kątownika 90°; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a surface plate and a 90° square; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płyty pomiarowej i kątownika 90°","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a surface plate and a 90° square","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n- błąd ustawienia wskazania zerowego 0 mm do 300 mm CMC 0,2 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płyty pomiarowej i kątownika 90°; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.38","norm_bases":["IW5.8.38"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Poziomnice budowlane Wzorcowanie — Kąt\n- błąd ustawienia wskazania zerowego 0 mm do 300 mm CMC 0,2 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płyty pomiarowej i kątownika 90°; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.38 Poziomnice budowlane Wzorcowanie — Kat\n- blad ustawienia wskazania zerowego 0 mm do 300 mm CMC 0,2 mm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plyty pomiarowej i katownika 90°; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.38","search_en":"Builder's spirit levels Calibration — Angle Internal procedure; Direct method using a surface plate and a 90° square; At permanent location (S) Angle Internal procedure Direct method using a surface plate and a 90° square At permanent location (S) - zero setting error Internal procedure IW5.8.38","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":67,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.38","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"- Nullpunkteinstellfehler","range":"0 mm to 300 mm","cmc":"0,2 mm"}],"reference_de":"Internes Verfahren IW5.8.38","regulatory_area_de":"Winkel","search_de":"Wasserwaagen für das Bauwesen Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit einer Messplatte und einem 90°-Winkel; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit einer Messplatte und einem 90°-Winkel Am festen Standort (S) - Nullpunkteinstellfehler Internes Verfahren IW5.8.38","technique_de":"Internes Verfahren; Direktes Verfahren mit einer Messplatte und einem 90°-Winkel; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einer Messplatte und einem 90°-Winkel","Am festen Standort (S)"],"test_object_de":"Wasserwaagen für das Bauwesen","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"- 零位示值设定误差","range":"0 mm to 300 mm","cmc":"0,2 mm"}],"reference_zh":"内部程序 IW5.8.38","regulatory_area_zh":"角度","search_zh":"建筑水平尺 校准 — 角度 内部程序；使用测量平板和90°直角尺的直接法；在固定地点 (S) 角度 内部程序 使用测量平板和90°直角尺的直接法 在固定地点 (S) - 零位示值设定误差 内部程序 IW5.8.38","technique_zh":"内部程序；使用测量平板和90°直角尺的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用测量平板和90°直角尺的直接法","在固定地点 (S)"],"test_object_zh":"建筑水平尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"- chyba nastavení nulové indikace","range":"0 mm to 300 mm","cmc":"0,2 mm"}],"reference_cs":"Vnitřní postup IW5.8.38","regulatory_area_cs":"Úhel","search_cs":"Stavební vodováhy Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím měřicí desky a úhelníku 90°; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím měřicí desky a úhelníku 90° Ve stálé lokalitě (S) - chyba nastavení nulové indikace Vnitřní postup IW5.8.38","technique_cs":"Vnitřní postup; Přímá metoda s použitím měřicí desky a úhelníku 90°; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím měřicí desky a úhelníku 90°","Ve stálé lokalitě (S)"],"test_object_cs":"Stavební vodováhy"},{"_id":"9d7d4f52a9e066c488d9e180","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Poziomnice cyfrowe","test_object_en":"Digital levels","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"± 90°","cmc":"0,06°"}],"parameters_en":[{"name":"","range":"± 90°","cmc":"0,06°"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem liniału sinusowego oraz płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using a sine bar and gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem liniału sinusowego oraz płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using a sine bar and gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n± 90° CMC 0,06°\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem liniału sinusowego oraz płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.38","norm_bases":["IW5.8.38"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Poziomnice cyfrowe Wzorcowanie — Kąt\n± 90° CMC 0,06°\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem liniału sinusowego oraz płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.38 Poziomnice cyfrowe Wzorcowanie — Kat\n± 90° CMC 0,06°\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem linialu sinusowego oraz plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.38","search_en":"Digital levels Calibration — Angle Internal procedure; Indirect method using a sine bar and gauge blocks; At permanent location (S) Angle Internal procedure Indirect method using a sine bar and gauge blocks At permanent location (S) Internal procedure IW5.8.38","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":68,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.38","methodology_de":"Kalibrierung — Winkel","reference_de":"Internes Verfahren IW5.8.38","regulatory_area_de":"Winkel","search_de":"Digitale Wasserwaagen Kalibrierung — Winkel Internes Verfahren; Indirektes Verfahren unter Verwendung eines Sinuslineals sowie von Parallelendmaßen; Am festen Standort (S) Winkel Internes Verfahren Indirektes Verfahren unter Verwendung eines Sinuslineals sowie von Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.38","technique_de":"Internes Verfahren; Indirektes Verfahren unter Verwendung eines Sinuslineals sowie von Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren unter Verwendung eines Sinuslineals sowie von Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Digitale Wasserwaagen","methodology_zh":"校准 — 角度","reference_zh":"内部程序 IW5.8.38","regulatory_area_zh":"角度","search_zh":"数显水平仪 校准 — 角度 内部程序；使用正弦规和量块的间接法；在固定地点 (S) 角度 内部程序 使用正弦规和量块的间接法 在固定地点 (S) 内部程序 IW5.8.38","technique_zh":"内部程序；使用正弦规和量块的间接法；在固定地点 (S)","techniques_zh":["内部程序","使用正弦规和量块的间接法","在固定地点 (S)"],"test_object_zh":"数显水平仪","methodology_cs":"Kalibrace — Úhel","reference_cs":"Vnitřní postup IW5.8.38","regulatory_area_cs":"Úhel","search_cs":"Digitální libely Kalibrace — Úhel Vnitřní postup; Nepřímá metoda s použitím sinusového pravítka a koncových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup Nepřímá metoda s použitím sinusového pravítka a koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.38","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím sinusového pravítka a koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím sinusového pravítka a koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální libely"},{"_id":"fff76e41b54e396401fc320b","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Poziomnice liniałowe","test_object_en":"Bar spirit levels","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"- błąd wartości działki elementarnej","range":"0 mm/m do 1 mm/m","cmc":"0,015 mm/m"},{"name":"- błąd ustawienia wskazania zerowego","range":"0 mm/m do 1 mm/m","cmc":"0,2 dz. el."}],"parameters_en":[{"name":"- error of the scale interval value","range":"0 mm/m to 1 mm/m","cmc":"0,015 mm/m"},{"name":"- zero setting error","range":"0 mm/m to 1 mm/m","cmc":"0,2 dz. el."}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem poziomnicy koincydencyjnej; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a coincidence level; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem poziomnicy koincydencyjnej","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a coincidence level","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\nZakres:\n- błąd wartości działki elementarnej 0 mm/m do 1 mm/m CMC 0,015 mm/m\n- błąd ustawienia wskazania zerowego 0 mm/m do 1 mm/m CMC 0,2 dz. el.\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem poziomnicy koincydencyjnej; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW.5.8.38","norm_bases":["IW.5.8.38"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Poziomnice liniałowe Wzorcowanie — Kąt\nZakres:\n- błąd wartości działki elementarnej 0 mm/m do 1 mm/m CMC 0,015 mm/m\n- błąd ustawienia wskazania zerowego 0 mm/m do 1 mm/m CMC 0,2 dz. el.\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem poziomnicy koincydencyjnej; W stałej lokalizacji (S) Procedura wewnętrzna IW.5.8.38 Poziomnice linialowe Wzorcowanie — Kat\nZakres:\n- blad wartosci dzialki elementarnej 0 mm/m do 1 mm/m CMC 0,015 mm/m\n- blad ustawienia wskazania zerowego 0 mm/m do 1 mm/m CMC 0,2 dz. el.\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem poziomnicy koincydencyjnej; W stalej lokalizacji (S) Procedura wewnetrzna IW.5.8.38","search_en":"Bar spirit levels Calibration — Angle Internal procedure; Direct method using a coincidence level; At permanent location (S) Angle Internal procedure Direct method using a coincidence level At permanent location (S) - error of the scale interval value - zero setting error Internal procedure IW.5.8.38","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":69,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW.5.8.38","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"- Fehler des Skalenteilungswerts","range":"0 mm/m to 1 mm/m","cmc":"0,015 mm/m"},{"name":"- Nullpunkteinstellfehler","range":"0 mm/m to 1 mm/m","cmc":"0,2 dz. el."}],"reference_de":"Internes Verfahren IW.5.8.38","regulatory_area_de":"Winkel","search_de":"Linealwasserwaagen Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit einer Koinzidenzlibelle; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit einer Koinzidenzlibelle Am festen Standort (S) - Fehler des Skalenteilungswerts - Nullpunkteinstellfehler Internes Verfahren IW.5.8.38","technique_de":"Internes Verfahren; Direktes Verfahren mit einer Koinzidenzlibelle; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einer Koinzidenzlibelle","Am festen Standort (S)"],"test_object_de":"Linealwasserwaagen","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"- 分度值误差","range":"0 mm/m to 1 mm/m","cmc":"0,015 mm/m"},{"name":"- 零位示值设定误差","range":"0 mm/m to 1 mm/m","cmc":"0,2 dz. el."}],"reference_zh":"内部程序 IW.5.8.38","regulatory_area_zh":"角度","search_zh":"尺式水平仪 校准 — 角度 内部程序；使用合像水平仪的直接法；在固定地点 (S) 角度 内部程序 使用合像水平仪的直接法 在固定地点 (S) - 分度值误差 - 零位示值设定误差 内部程序 IW.5.8.38","technique_zh":"内部程序；使用合像水平仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用合像水平仪的直接法","在固定地点 (S)"],"test_object_zh":"尺式水平仪","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"- chyba hodnoty dílku","range":"0 mm/m to 1 mm/m","cmc":"0,015 mm/m"},{"name":"- chyba nastavení nulové indikace","range":"0 mm/m to 1 mm/m","cmc":"0,2 dz. el."}],"reference_cs":"Vnitřní postup IW.5.8.38","regulatory_area_cs":"Úhel","search_cs":"Pravítkové libely Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím koincidenční libely; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím koincidenční libely Ve stálé lokalitě (S) - chyba hodnoty dílku - chyba nastavení nulové indikace Vnitřní postup IW.5.8.38","technique_cs":"Vnitřní postup; Přímá metoda s použitím koincidenční libely; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koincidenční libely","Ve stálé lokalitě (S)"],"test_object_cs":"Pravítkové libely"},{"_id":"d92064beded4b3a3d27cd828","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Spoinomierze","test_object_en":"Weld gauges","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"- kąt ukosowania","range":"80° do 160°","cmc":"0,6°"}],"parameters_en":[{"name":"- bevel angle","range":"80° to 160°","cmc":"0,6°"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using angle gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using angle gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n- kąt ukosowania 80° do 160° CMC 0,6°\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.40","norm_bases":["IW5.8.40"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Spoinomierze Wzorcowanie — Kąt\n- kąt ukosowania 80° do 160° CMC 0,6°\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.40 Spoinomierze Wzorcowanie — Kat\n- kat ukosowania 80° do 160° CMC 0,6°\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych katowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.40","search_en":"Weld gauges Calibration — Angle Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Angle Internal procedure Direct method using angle gauge blocks At permanent location (S) - bevel angle Internal procedure IW5.8.40","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":70,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.40","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"- Fugenflankenwinkel","range":"80° to 160°","cmc":"0,6°"}],"reference_de":"Internes Verfahren IW5.8.40","regulatory_area_de":"Winkel","search_de":"Schweißnahtlehren Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit Winkelendmaßen Am festen Standort (S) - Fugenflankenwinkel Internes Verfahren IW5.8.40","technique_de":"Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Winkelendmaßen","Am festen Standort (S)"],"test_object_de":"Schweißnahtlehren","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"- 坡口角度","range":"80° to 160°","cmc":"0,6°"}],"reference_zh":"内部程序 IW5.8.40","regulatory_area_zh":"角度","search_zh":"焊缝量规 校准 — 角度 内部程序；使用角度量块的直接法；在固定地点 (S) 角度 内部程序 使用角度量块的直接法 在固定地点 (S) - 坡口角度 内部程序 IW5.8.40","technique_zh":"内部程序；使用角度量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用角度量块的直接法","在固定地点 (S)"],"test_object_zh":"焊缝量规","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"- úhel úkosu","range":"80° to 160°","cmc":"0,6°"}],"reference_cs":"Vnitřní postup IW5.8.40","regulatory_area_cs":"Úhel","search_cs":"Svarové měrky Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím úhlových koncových měrek Ve stálé lokalitě (S) - úhel úkosu Vnitřní postup IW5.8.40","technique_cs":"Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím úhlových koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Svarové měrky"},{"_id":"4479982883844ec05338aba4","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Liniały krawędziowe","test_object_en":"Straight edges","methodology":"Wzorcowanie — Długość (geometria powierzchni)","methodology_en":"Calibration — Length (surface geometry)","parameters":[{"name":"","range":"0 mm do 300 mm","cmc":"3 µm"}],"parameters_en":[{"name":"","range":"0 mm to 300 mm","cmc":"3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (geometria powierzchni)\n0 mm do 300 mm CMC 3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.36","norm_bases":["IW5.8.36"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (geometria powierzchni)","regulatory_area_en":"Length (surface geometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Liniały krawędziowe Wzorcowanie — Długość (geometria powierzchni)\n0 mm do 300 mm CMC 3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.36 Linialy krawedziowe Wzorcowanie — Dlugosc (geometria powierzchni)\n0 mm do 300 mm CMC 3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.36","search_en":"Straight edges Calibration — Length (surface geometry) Internal procedure; Direct method using gauge blocks; At permanent location (S) Length (surface geometry) Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW5.8.36","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":71,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.36","methodology_de":"Kalibrierung — Länge (Oberflächengeometrie)","parameters_de":[{"name":"","range":"0 mm to 300 mm","cmc":"3 µm"}],"reference_de":"Internes Verfahren IW5.8.36","regulatory_area_de":"Länge (Oberflächengeometrie)","search_de":"Haarlineale Kalibrierung — Länge (Oberflächengeometrie) Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge (Oberflächengeometrie) Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW5.8.36","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Haarlineale","methodology_zh":"校准 — 长度（表面几何）","parameters_zh":[{"name":"","range":"0 mm to 300 mm","cmc":"3 µm"}],"reference_zh":"内部程序 IW5.8.36","regulatory_area_zh":"长度（表面几何）","search_zh":"刀口尺 校准 — 长度（表面几何） 内部程序；使用量块的直接法；在固定地点 (S) 长度（表面几何） 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW5.8.36","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"刀口尺","methodology_cs":"Kalibrace — Délka (geometrie povrchu)","parameters_cs":[{"name":"","range":"0 mm to 300 mm","cmc":"3 µm"}],"reference_cs":"Vnitřní postup IW5.8.36","regulatory_area_cs":"Délka (geometrie povrchu)","search_cs":"Nožová pravítka Kalibrace — Délka (geometrie povrchu) Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka (geometrie povrchu) Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW5.8.36","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Nožová pravítka"},{"_id":"73d94d211ba98d51881625d2","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Siłomierze (dynamometry teletechniczne)","test_object_en":"Force gauges (telecommunication dynamometers)","methodology":"Wzorcowanie — Siła","methodology_en":"Calibration — Force","parameters":[{"name":"","range":"2 cN do 245 cN","cmc":"0,76 cN"}],"parameters_en":[{"name":"","range":"2 cN to 245 cN","cmc":"0,76 cN"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Siła\n2 cN do 245 cN CMC 0,76 cN\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.1","norm_bases":["IW5.8.1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Siła","regulatory_area_en":"Force","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Siłomierze (dynamometry teletechniczne) Wzorcowanie — Siła\n2 cN do 245 cN CMC 0,76 cN\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.1 Silomierze (dynamometry teletechniczne) Wzorcowanie — Sila\n2 cN do 245 cN CMC 0,76 cN\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.1","search_en":"Force gauges (telecommunication dynamometers) Calibration — Force Internal procedure; At permanent location (S) Force Internal procedure At permanent location (S) Internal procedure IW5.8.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":72,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.1","methodology_de":"Kalibrierung — Kraft","parameters_de":[{"name":"","range":"2 cN to 245 cN","cmc":"0,76 cN"}],"reference_de":"Internes Verfahren IW5.8.1","regulatory_area_de":"Kraft","search_de":"Kraftmessgeräte (Fernmelde-Dynamometer) Kalibrierung — Kraft Internes Verfahren; Am festen Standort (S) Kraft Internes Verfahren Am festen Standort (S) Internes Verfahren IW5.8.1","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kraftmessgeräte (Fernmelde-Dynamometer)","methodology_zh":"校准 — 力","parameters_zh":[{"name":"","range":"2 cN to 245 cN","cmc":"0,76 cN"}],"reference_zh":"内部程序 IW5.8.1","regulatory_area_zh":"力","search_zh":"测力计（电信用测力计） 校准 — 力 内部程序；在固定地点 (S) 力 内部程序 在固定地点 (S) 内部程序 IW5.8.1","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"测力计（电信用测力计）","methodology_cs":"Kalibrace — Síla","parameters_cs":[{"name":"","range":"2 cN to 245 cN","cmc":"0,76 cN"}],"reference_cs":"Vnitřní postup IW5.8.1","regulatory_area_cs":"Síla","search_cs":"Siloměry (telekomunikační dynamometry) Kalibrace — Síla Vnitřní postup; Ve stálé lokalitě (S) Síla Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup IW5.8.1","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Siloměry (telekomunikační dynamometry)"},{"_id":"73f502e9bb151b5d561b1674","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Klucze dynamometryczne","test_object_en":"Torque wrenches","methodology":"Wzorcowanie — Moment siły","methodology_en":"Calibration — Torque","parameters":[{"name":"","range":"0,5 Nm do 1500 Nm","cmc":"0,62 %"}],"parameters_en":[{"name":"","range":"0,5 Nm to 1500 Nm","cmc":"0,62 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moment siły\n0,5 Nm do 1500 Nm CMC 0,62 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.2 w oparciu o PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","norm_bases":["IW5.8.2","PN-EN ISO 6789-1:2017","PN-EN ISO 6789-2:2017"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moment siły","regulatory_area_en":"Torque","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Klucze dynamometryczne Wzorcowanie — Moment siły\n0,5 Nm do 1500 Nm CMC 0,62 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.2 w oparciu o PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017 Klucze dynamometryczne Wzorcowanie — Moment sily\n0,5 Nm do 1500 Nm CMC 0,62 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.2 w oparciu o PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","search_en":"Torque wrenches Calibration — Torque Internal procedure; At permanent location (S) Torque Internal procedure At permanent location (S) Internal procedure IW5.8.2 based on PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":73,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.2 based on PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","methodology_de":"Kalibrierung — Drehmoment","parameters_de":[{"name":"","range":"0,5 Nm to 1500 Nm","cmc":"0,62 %"}],"reference_de":"Internes Verfahren IW5.8.2 auf Grundlage von PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","regulatory_area_de":"Drehmoment","search_de":"Drehmomentschlüssel Kalibrierung — Drehmoment Internes Verfahren; Am festen Standort (S) Drehmoment Internes Verfahren Am festen Standort (S) Internes Verfahren IW5.8.2 auf Grundlage von PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Drehmomentschlüssel","methodology_zh":"校准 — 力矩","parameters_zh":[{"name":"","range":"0,5 Nm to 1500 Nm","cmc":"0,62 %"}],"reference_zh":"内部程序 IW5.8.2 依据PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","regulatory_area_zh":"力矩","search_zh":"扭矩扳手 校准 — 力矩 内部程序；在固定地点 (S) 力矩 内部程序 在固定地点 (S) 内部程序 IW5.8.2 依据PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"扭矩扳手","methodology_cs":"Kalibrace — Moment síly","parameters_cs":[{"name":"","range":"0,5 Nm to 1500 Nm","cmc":"0,62 %"}],"reference_cs":"Vnitřní postup IW5.8.2 na základě PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","regulatory_area_cs":"Moment síly","search_cs":"Momentové klíče Kalibrace — Moment síly Vnitřní postup; Ve stálé lokalitě (S) Moment síly Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup IW5.8.2 na základě PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Momentové klíče"},{"_id":"81421d29a7549145ee74282a","lab_id":"6afa3b9a8989a133b76445c6","country":"PL","accr_number":"AP 171","accr_body":"PCA","test_object":"Wkrętaki dynamometryczne","test_object_en":"Torque screwdrivers","methodology":"Wzorcowanie — Moment siły","methodology_en":"Calibration — Torque","parameters":[{"name":"","range":"0,04 Nm do 10 Nm","cmc":"0,85 %"}],"parameters_en":[{"name":"","range":"0,04 Nm to 10 Nm","cmc":"0,85 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moment siły\n0,04 Nm do 10 Nm CMC 0,85 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW5.8.2 w oparciu o PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","norm_bases":["IW5.8.2","PN-EN ISO 6789-1:2017","PN-EN ISO 6789-2:2017"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moment siły","regulatory_area_en":"Torque","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wkrętaki dynamometryczne Wzorcowanie — Moment siły\n0,04 Nm do 10 Nm CMC 0,85 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna IW5.8.2 w oparciu o PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017 Wkretaki dynamometryczne Wzorcowanie — Moment sily\n0,04 Nm do 10 Nm CMC 0,85 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna IW5.8.2 w oparciu o PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","search_en":"Torque screwdrivers Calibration — Torque Internal procedure; At permanent location (S) Torque Internal procedure At permanent location (S) Internal procedure IW5.8.2 based on PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":74,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW5.8.2 based on PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","methodology_de":"Kalibrierung — Drehmoment","parameters_de":[{"name":"","range":"0,04 Nm to 10 Nm","cmc":"0,85 %"}],"reference_de":"Internes Verfahren IW5.8.2 auf Grundlage von PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","regulatory_area_de":"Drehmoment","search_de":"Drehmomentschraubendreher Kalibrierung — Drehmoment Internes Verfahren; Am festen Standort (S) Drehmoment Internes Verfahren Am festen Standort (S) Internes Verfahren IW5.8.2 auf Grundlage von PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Drehmomentschraubendreher","methodology_zh":"校准 — 力矩","parameters_zh":[{"name":"","range":"0,04 Nm to 10 Nm","cmc":"0,85 %"}],"reference_zh":"内部程序 IW5.8.2 依据PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","regulatory_area_zh":"力矩","search_zh":"扭矩螺丝刀 校准 — 力矩 内部程序；在固定地点 (S) 力矩 内部程序 在固定地点 (S) 内部程序 IW5.8.2 依据PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"扭矩螺丝刀","methodology_cs":"Kalibrace — Moment síly","parameters_cs":[{"name":"","range":"0,04 Nm to 10 Nm","cmc":"0,85 %"}],"reference_cs":"Vnitřní postup IW5.8.2 na základě PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","regulatory_area_cs":"Moment síly","search_cs":"Momentové šroubováky Kalibrace — Moment síly Vnitřní postup; Ve stálé lokalitě (S) Moment síly Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup IW5.8.2 na základě PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Momentové šroubováky"}],"has_pdf":true}