{"lab":{"_id":"6ae132eeff068247617088c0","accr_number":"AP 169","country":"PL","imported_at":"2026-10-27T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"ul. Daniszewska 4, 03-230 Warszawa","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"12.01.2021","city":"Warszawa","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units.","cycle_from":"25.11.2024","cycle_to":"20.12.2028","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"20.01","pl":"objętość","en":"volume"}],"has_en":true,"has_zh":false,"issue":{"no":"6","date":"25.11.2024"},"issue_date":"25.11.2024","issue_number":"6","lab_division":null,"lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[21.017495,52.3096963]},"map_coord":[52.3096963,21.017495],"map_geo":"nominatim-street","methods_count":1,"name":"CORNING HTL S.A.","parse_date":"2026-10-27T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-10-27T12:00:00.000Z","pdf_files":["AP_169.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: objętość. W stałej lokalizacji (S).","search_text":"corning htl s.a. ul. daniszewska 4, 03-230 warszawa laboratorium wzorcujące. wielkości mierzone: objętość. w stałej lokalizacji (s). ap 169 ap169 laboratorium wzorcujące wzorcowanie kalibracja volume corning htl s.a. ul. daniszewska 4, 03-230 warszawa laboratorium wzorcujace. wielkosci mierzone: objetosc. w stalej lokalizacji (s). ap 169 ap169 laboratorium wzorcujace wzorcowanie kalibracja volume","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20169,podmiot.html","source_pdf_sha256":"f0160be9fcc37685ee623e6a1baa7ebef98774cb88f302c1fa6e92349e3a0cd8","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/10/27/e598d53a51ce6a2474dd6d78e5a05d0a/AP%20169.pdf","status":"active","updated_at":"2026-10-27T12:00:00.000Z","valid_from":"21-12-2016","valid_until":"20-12-2028","website":"www.htl.pl"},"methods":[{"_id":"9c84c049467119bede124147","lab_id":"6ae132eeff068247617088c0","country":"PL","accr_number":"AP 169","accr_body":"PCA","test_object":"Pipety tłokowe","test_object_en":"Piston pipettes","methodology":"Wzorcowanie — Objętość","methodology_en":"Calibration — Volume","parameters":[{"name":"","range":"0,2 μl do 20 μl","cmc":"0,050 μl"},{"name":"","range":"20 μl do 50)μl","cmc":"0,23 μl"},{"name":"","range":"50 μl do 200 μl","cmc":"0,33 μl"},{"name":"","range":"200 μl do 500 μl","cmc":"1,6 μl"},{"name":"","range":"500 μl do 1000 μl","cmc":"2,6 μl"},{"name":"","range":"1000 μl do 2500 μl","cmc":"6,0 μl"},{"name":"","range":"2500 μl do 5000 μl","cmc":"10,0 μl"},{"name":"","range":"5000 μl do 10000 μl","cmc":"16,0 μl"}],"parameters_en":[{"name":"","range":"0,2 μl to 20 μl","cmc":"0,050 μl"},{"name":"","range":"20 μl to 50)μl","cmc":"0,23 μl"},{"name":"","range":"50 μl to 200 μl","cmc":"0,33 μl"},{"name":"","range":"200 μl to 500 μl","cmc":"1,6 μl"},{"name":"","range":"500 μl to 1000 μl","cmc":"2,6 μl"},{"name":"","range":"1000 μl to 2500 μl","cmc":"6,0 μl"},{"name":"","range":"2500 μl to 5000 μl","cmc":"10,0 μl"},{"name":"","range":"5000 μl to 10000 μl","cmc":"16,0 μl"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Objętość\nZakres:\n0,2 μl do 20 μl CMC 0,050 μl\n20 μl do 50)μl CMC 0,23 μl\n50 μl do 200 μl CMC 0,33 μl\n200 μl do 500 μl CMC 1,6 μl\n500 μl do 1000 μl CMC 2,6 μl\n1000 μl do 2500 μl CMC 6,0 μl\n2500 μl do 5000 μl CMC 10,0 μl\n5000 μl do 10000 μl CMC 16,0 μl\nW stałej lokalizacji (S)","reference":"PN-EN ISO 8655-6:2022","norm_bases":["PN-EN ISO 8655-6:2022"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Objętość","regulatory_area_en":"Volume","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Pipety tłokowe Wzorcowanie — Objętość\nZakres:\n0,2 μl do 20 μl CMC 0,050 μl\n20 μl do 50)μl CMC 0,23 μl\n50 μl do 200 μl CMC 0,33 μl\n200 μl do 500 μl CMC 1,6 μl\n500 μl do 1000 μl CMC 2,6 μl\n1000 μl do 2500 μl CMC 6,0 μl\n2500 μl do 5000 μl CMC 10,0 μl\n5000 μl do 10000 μl CMC 16,0 μl\nW stałej lokalizacji (S) PN-EN ISO 8655-6:2022 Pipety tlokowe Wzorcowanie — Objetosc\nZakres:\n0,2 μl do 20 μl CMC 0,050 μl\n20 μl do 50)μl CMC 0,23 μl\n50 μl do 200 μl CMC 0,33 μl\n200 μl do 500 μl CMC 1,6 μl\n500 μl do 1000 μl CMC 2,6 μl\n1000 μl do 2500 μl CMC 6,0 μl\n2500 μl do 5000 μl CMC 10,0 μl\n5000 μl do 10000 μl CMC 16,0 μl\nW stalej lokalizacji (S) PN-EN ISO 8655-6:2022","search_en":"Piston pipettes Calibration — Volume\nScope:\n0,2 μl to 20 μl CMC 0,050 μl\n20 μl to 50)μl CMC 0,23 μl\n50 μl to 200 μl CMC 0,33 μl\n200 μl to 500 μl CMC 1,6 μl\n500 μl to 1000 μl CMC 2,6 μl\n1000 μl to 2500 μl CMC 6,0 μl\n2500 μl to 5000 μl CMC 10,0 μl\n5000 μl to 10000 μl CMC 16,0 μl\nAt permanent location (S) PN-EN ISO 8655-6:2022","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1"}],"has_pdf":true}