{"lab":{"_id":"6ae132ebff068247617088b8","country":"PL","accr_number":"AP 155","imported_at":"2026-10-27T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"ul. Wilhelma Konrada Roentgena 5, 02-781 Warszawa","approver":"Tadeusz Matras","categories":["metrology"],"certificate_date":"30.07.2020","city":"Warszawa","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 %. Wartość wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The value expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand.","cycle_from":"06.05.2026","cycle_to":"27.05.2030","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"18.01","pl":"wielkości dozymetryczne","en":"dosimetric quantities"}],"has_en":true,"has_zh":false,"issue":{"no":"10","date":"06.05.2026"},"issue_date":"06.05.2026","issue_number":"10","lab_division":"Zakład Fizyki Medycznej Pracownia Wtórnych Wzorców Dozymetrycznych","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[21.031607,52.1474119]},"map_coord":[52.1474119,21.031607],"map_geo":"nominatim-street","methods_count":1,"name":"Narodowy Instytut Onkologii im. Marii Skłodowskiej-Curie - Państwowy Instytut Badawczy","parse_date":"2026-10-27T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-10-27T12:00:00.000Z","pdf_files":["AP_155.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: wielkości dozymetryczne. W stałej lokalizacji (S).","search_text":"narodowy instytut onkologii im. marii skłodowskiej-curie - państwowy instytut badawczy zakład fizyki medycznej pracownia wtórnych wzorców dozymetrycznych ul. wilhelma konrada roentgena 5, 02-781 warszawa laboratorium wzorcujące. wielkości mierzone: wielkości dozymetryczne. w stałej lokalizacji (s). ap 155 ap155 laboratorium wzorcujące wzorcowanie kalibracja dosimetric quantities narodowy instytut onkologii im. marii sklodowskiej-curie - panstwowy instytut badawczy zaklad fizyki medycznej pracownia wtornych wzorcow dozymetrycznych ul. wilhelma konrada roentgena 5, 02-781 warszawa laboratorium wzorcujace. wielkosci mierzone: wielkosci dozymetryczne. w stalej lokalizacji (s). ap 155 ap155 laboratorium wzorcujace wzorcowanie kalibracja dosimetric quantities","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20155,podmiot.html","source_pdf_sha256":"b3df5c777d0941d1dac83e7d22717e2a394d5b55ca442e98bdb50e241f57dca0","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/10/27/e5d9aedd2c79ed4001b356280776824a/AP%20155.pdf","status":"active","updated_at":"2026-10-27T12:00:00.000Z","valid_from":"28-05-2014","valid_until":"27-05-2030","website":"zfm.coi.pl"},"methods":[{"_id":"0fb6cd47c2a389866e740755","lab_id":"6ae132ebff068247617088b8","country":"PL","accr_number":"AP 155","accr_body":"PCA","test_object":"Dawkomierze promieniowania jonizującego","test_object_en":"Ionising radiation dosimeters","methodology":"Wzorcowanie — Wielkości dozymetryczne","methodology_en":"Calibration — Dosimetric quantities","parameters":[{"name":"dawka pochłonięta w wodzie (Co-60)","range":"0,15 Gy do 3,3 Gy","cmc":"1,5 %"},{"name":"kerma w powietrzu (Ir-192)","range":"0,1 mGy do 0,4 mGy","cmc":"3,0 %"}],"parameters_en":[{"name":"absorbed dose to water (Co-60)","range":"0,15 Gy to 3,3 Gy","cmc":"1,5 %"},{"name":"air kerma (Ir-192)","range":"0,1 mGy to 0,4 mGy","cmc":"3,0 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości dozymetryczne\nZakres:\ndawka pochłonięta w wodzie (Co-60) 0,15 Gy do 3,3 Gy CMC 1,5 %\nkerma w powietrzu (Ir-192) 0,1 mGy do 0,4 mGy CMC 3,0 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PR22.5_P1_IR2, PR22.5_P1_IR14","norm_bases":["PR22.5_P1_IR2","PR22.5_P1_IR14"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości dozymetryczne","regulatory_area_en":"Dosimetric quantities","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Dawkomierze promieniowania jonizującego Wzorcowanie — Wielkości dozymetryczne\nZakres:\ndawka pochłonięta w wodzie (Co-60) 0,15 Gy do 3,3 Gy CMC 1,5 %\nkerma w powietrzu (Ir-192) 0,1 mGy do 0,4 mGy CMC 3,0 %\nProcedura wewnętrzna; W stałej lokalizacji (S) PR22.5_P1_IR2, PR22.5_P1_IR14 Dawkomierze promieniowania jonizujacego Wzorcowanie — Wielkosci dozymetryczne\nZakres:\ndawka pochlonieta w wodzie (Co-60) 0,15 Gy do 3,3 Gy CMC 1,5 %\nkerma w powietrzu (Ir-192) 0,1 mGy do 0,4 mGy CMC 3,0 %\nProcedura wewnetrzna; W stalej lokalizacji (S) PR22.5_P1_IR2, PR22.5_P1_IR14","search_en":"Ionising radiation dosimeters Calibration — Dosimetric quantities\nScope:\nabsorbed dose to water (Co-60) 0,15 Gy to 3,3 Gy CMC 1,5 %\nair kerma (Ir-192) 0,1 mGy to 0,4 mGy CMC 3,0 %\nInternal procedure; At permanent location (S) PR22.5_P1_IR2, PR22.5_P1_IR14","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1"}],"has_pdf":true}