{"lab":{"_id":"6afad8058989a133b76447bd","accr_number":"AP 136","country":"PL","imported_at":"2026-11-16T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Ostrowska 388, 61-312 Poznań","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"","city":"Poznań","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 %. Niepewność pomiaru dla CMC wyrażona jest w jednostkach wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The uncertainty covered by the CMC is expressed in measurand units.","cycle_from":"16.06.2026","cycle_to":"23.06.2030","email_source":"PCA","en_official":true,"fields_of_testing":[{"codes":"1.02","pl":"prędkość","en":"speed","de":"Geschwindigkeit","zh":"速度","cs":"rychlost"},{"codes":"6.01","pl":"długość","en":"length","de":"Länge","zh":"长度","cs":"délka"},{"codes":"12.01","pl":"siła","en":"force","de":"Kraft","zh":"力","cs":"síla"},{"codes":"13.01","pl":"twardość","en":"hardness","de":"Härte","zh":"硬度","cs":"tvrdost"},{"codes":"16.05","pl":"wielkości radiometryczne","en":"radiometric quantities","de":"radiometrische Größen","zh":"辐射度量","cs":"radiometrické veličiny"},{"codes":"16.06","pl":"natężenie oświetlenia","en":"illuminance","de":"Beleuchtungsstärke","zh":"照度","cs":"intenzita osvětlení"},{"codes":"17.01","pl":"ciśnienie","en":"pressure","de":"Druck","zh":"压力","cs":"tlak"},{"codes":"19.01","pl":"temperatura (termometria elektryczna)","en":"temperature (electrical thermometry)","de":"Temperatur (elektrische Thermometrie)","zh":"温度（电测温）","cs":"teplota (elektrická termometrie)"},{"codes":"19.03","pl":"temperatura (termometria radiacyjna)","en":"temperature (radiation thermometry)","de":"Temperatur (Strahlungsthermometrie)","zh":"温度（辐射测温）","cs":"teplota (radiační termometrie)"}],"has_en":true,"has_zh":true,"issue":{"no":"18","date":"16.06.2026"},"issue_date":"16.06.2026","issue_number":"18","lab_division":"Wydział Metrologii i Zarządzania WBP","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[16.9971204,52.3619741]},"map_coord":[52.3619741,16.9971204],"map_geo":"nominatim-street","methods_count":28,"name":"Urząd Dozoru Technicznego","parse_date":"2026-11-16T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-16T12:00:00.000Z","pdf_files":["AP_136.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: prędkość, długość, siła, twardość, wielkości radiometryczne, natężenie oświetlenia, ciśnienie, temperatura (termometria elektryczna), temperatura (termometria radiacyjna). W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"urząd dozoru technicznego wydział metrologii i zarządzania wbp ul. ostrowska 388, 61-312 poznań laboratorium wzorcujące. wielkości mierzone: prędkość, długość, siła, twardość, wielkości radiometryczne, natężenie oświetlenia, ciśnienie, temperatura (termometria elektryczna), temperatura (termometria radiacyjna). w stałej lokalizacji (s) i/lub poza nią (p). ap 136 ap136 laboratorium wzorcujące wzorcowanie kalibracja speed length force hardness radiometric quantities illuminance pressure temperature (electrical thermometry) temperature (radiation thermometry) urzad dozoru technicznego wydzial metrologii i zarzadzania wbp ul. ostrowska 388, 61-312 poznan laboratorium wzorcujace. wielkosci mierzone: predkosc, dlugosc, sila, twardosc, wielkosci radiometryczne, natezenie oswietlenia, cisnienie, temperatura (termometria elektryczna), temperatura (termometria radiacyjna). w stalej lokalizacji (s) i/lub poza nia (p). ap 136 ap136 laboratorium wzorcujace wzorcowanie kalibracja speed length force hardness radiometric quantities illuminance pressure temperature (electrical thermometry) temperature (radiation thermometry)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20136,podmiot.html","source_pdf_sha256":"790189eb3eb1fbdcddf9a1e5d4e1682e0847e13b3b241aeca460c9286f040152","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/16/232a12130c1e57382b2470b70c268e24/AP%20136.pdf","status":"active","updated_at":"2026-11-16T12:00:00.000Z","valid_from":"24-06-2010","valid_until":"23-06-2030","website":"www.udt.gov.pl","lab_division_en":"Department of Metrology and Management WBP","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 %. Die Messunsicherheit der CMC wird in Einheiten der Messgröße angegeben.","has_de":true,"lab_division_de":"Abteilung für Metrologie und Management WBP","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度。CMC测量不确定度以被测量的单位表示。","lab_division_zh":"WBP 计量与管理部","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 %. Nejistota měření CMC je vyjádřena v jednotkách měřené veličiny.","has_cs":true,"lab_division_cs":"Oddělení metrologie a řízení WBP","pelny_cs":true},"methods":[{"_id":"e44374adf72f9f3e2669d8f7","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Tachometry cyfrowe","test_object_en":"Digital tachometers","methodology":"Wzorcowanie — Prędkość","methodology_en":"Calibration — Speed","parameters":[{"name":"","range":"10,00 obr/min do 99,99 obr/min","cmc":"0,1 obr/min"},{"name":"","range":"100,0 obr/min do 999,9 obr/min","cmc":"0,2 obr/min"},{"name":"","range":"1000 obr/min do 33000 obr/min","cmc":"2 obr/min"},{"name":"","range":"33001 obr/min do 50000 obr/min","cmc":"3 obr/min"}],"parameters_en":[{"name":"","range":"10,00 rpm to 99,99 rpm","cmc":"0,1 rpm"},{"name":"","range":"100,0 rpm to 999,9 rpm","cmc":"0,2 rpm"},{"name":"","range":"1000 rpm to 33000 rpm","cmc":"2 rpm"},{"name":"","range":"33001 rpm to 50000 rpm","cmc":"3 rpm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia\nMetoda optyczna; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method\nOptical method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia\nMetoda optyczna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method\nOptical method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prędkość\nZakres:\n10,00 obr/min do 99,99 obr/min CMC 0,1 obr/min\n100,0 obr/min do 999,9 obr/min CMC 0,2 obr/min\n1000 obr/min do 33000 obr/min CMC 2 obr/min\n33001 obr/min do 50000 obr/min CMC 3 obr/min\nProcedura wewnętrzna; Metoda bezpośrednia\nMetoda optyczna; W stałej lokalizacji (S)","reference":"LW-1/IN/203","norm_bases":["LW-1/IN/203"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prędkość","regulatory_area_en":"Speed","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Tachometry cyfrowe Wzorcowanie — Prędkość\nZakres:\n10,00 obr/min do 99,99 obr/min CMC 0,1 obr/min\n100,0 obr/min do 999,9 obr/min CMC 0,2 obr/min\n1000 obr/min do 33000 obr/min CMC 2 obr/min\n33001 obr/min do 50000 obr/min CMC 3 obr/min\nProcedura wewnętrzna; Metoda bezpośrednia\nMetoda optyczna; W stałej lokalizacji (S) LW-1/IN/203 Tachometry cyfrowe Wzorcowanie — Predkosc\nZakres:\n10,00 obr/min do 99,99 obr/min CMC 0,1 obr/min\n100,0 obr/min do 999,9 obr/min CMC 0,2 obr/min\n1000 obr/min do 33000 obr/min CMC 2 obr/min\n33001 obr/min do 50000 obr/min CMC 3 obr/min\nProcedura wewnetrzna; Metoda bezposrednia\nMetoda optyczna; W stalej lokalizacji (S) LW-1/IN/203","search_en":"Digital tachometers Calibration — Speed Internal procedure; Direct method Optical method; At permanent location (S) Speed Internal procedure Direct method Optical method At permanent location (S) LW-1/IN/203","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Geschwindigkeit","parameters_de":[{"name":"","range":"10,00 rpm to 99,99 rpm","cmc":"0,1 U/min"},{"name":"","range":"100,0 rpm to 999,9 rpm","cmc":"0,2 U/min"},{"name":"","range":"1000 rpm to 33000 rpm","cmc":"2 U/min"},{"name":"","range":"33001 rpm to 50000 rpm","cmc":"3 U/min"}],"regulatory_area_de":"Geschwindigkeit","search_de":"Digitale Drehzahlmesser Kalibrierung — Geschwindigkeit Interne Verfahrensanweisung; Direktes Verfahren Optisches Verfahren; Am festen Standort (S) Geschwindigkeit Internes Verfahren Direktes Verfahren Optisches Verfahren Am festen Standort (S) LW-1/IN/203","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren\nOptisches Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren\nOptisches Verfahren","Am festen Standort (S)"],"test_object_de":"Digitale Drehzahlmesser","methodology_zh":"校准 — 速度","parameters_zh":[{"name":"","range":"10,00 rpm to 99,99 rpm","cmc":"0,1 转/分"},{"name":"","range":"100,0 rpm to 999,9 rpm","cmc":"0,2 r/min"},{"name":"","range":"1000 rpm to 33000 rpm","cmc":"2 r/min"},{"name":"","range":"33001 rpm to 50000 rpm","cmc":"3 r/min"}],"regulatory_area_zh":"速度","search_zh":"数字转速表 校准 — 速度 内部程序；直接法 光学法; 在固定地点 (S) 速度 内部程序 直接法 光学法 在固定地点 (S) LW-1/IN/203","technique_zh":"内部程序；直接法\n光学法; 在固定地点 (S)","techniques_zh":["内部程序","直接法\n光学法","在固定地点 (S)"],"test_object_zh":"数字转速表","methodology_cs":"Kalibrace — Rychlost","parameters_cs":[{"name":"","range":"10,00 rpm to 99,99 rpm","cmc":"0,1 ot./min"},{"name":"","range":"100,0 rpm to 999,9 rpm","cmc":"0,2 ot/min"},{"name":"","range":"1000 rpm to 33000 rpm","cmc":"2 ot/min"},{"name":"","range":"33001 rpm to 50000 rpm","cmc":"3 ot/min"}],"regulatory_area_cs":"Rychlost","search_cs":"Digitální otáčkoměry Kalibrace — Rychlost Vnitřní postup; Přímá metoda Optická metoda; Ve stálé lokalitě (S) Rychlost Vnitřní postup Přímá metoda Optická metoda Ve stálé lokalitě (S) LW-1/IN/203","technique_cs":"Vnitřní postup; Přímá metoda\nOptická metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda\nOptická metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální otáčkoměry"},{"_id":"2082f8cf9db8020fb53ceef8","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Tachometry cyfrowe","test_object_en":"Digital tachometers","methodology":"Wzorcowanie — Prędkość","methodology_en":"Calibration — Speed","parameters":[{"name":"","range":"10,00 obr/min do 99,99 obr/min","cmc":"0,1 obr/min"},{"name":"","range":"100,0 obr/min do 999,9 obr/min","cmc":"0,2 obr/min"},{"name":"","range":"1000 obr/min do 20000 obr/min","cmc":"2 obr/min"}],"parameters_en":[{"name":"","range":"10,00 rpm to 99,99 rpm","cmc":"0,1 rpm"},{"name":"","range":"100,0 rpm to 999,9 rpm","cmc":"0,2 rpm"},{"name":"","range":"100 0 rpm to 20000 rpm","cmc":"2 rpm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia\nMetoda stykowa; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method\nContact method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia\nMetoda stykowa","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method\nContact method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prędkość\nZakres:\n10,00 obr/min do 99,99 obr/min CMC 0,1 obr/min\n100,0 obr/min do 999,9 obr/min CMC 0,2 obr/min\n1000 obr/min do 20000 obr/min CMC 2 obr/min\nProcedura wewnętrzna; Metoda bezpośrednia\nMetoda stykowa; W stałej lokalizacji (S)","reference":"LW-1/IN/203","norm_bases":["LW-1/IN/203"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prędkość","regulatory_area_en":"Speed","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Tachometry cyfrowe Wzorcowanie — Prędkość\nZakres:\n10,00 obr/min do 99,99 obr/min CMC 0,1 obr/min\n100,0 obr/min do 999,9 obr/min CMC 0,2 obr/min\n1000 obr/min do 20000 obr/min CMC 2 obr/min\nProcedura wewnętrzna; Metoda bezpośrednia\nMetoda stykowa; W stałej lokalizacji (S) LW-1/IN/203 Tachometry cyfrowe Wzorcowanie — Predkosc\nZakres:\n10,00 obr/min do 99,99 obr/min CMC 0,1 obr/min\n100,0 obr/min do 999,9 obr/min CMC 0,2 obr/min\n1000 obr/min do 20000 obr/min CMC 2 obr/min\nProcedura wewnetrzna; Metoda bezposrednia\nMetoda stykowa; W stalej lokalizacji (S) LW-1/IN/203","search_en":"Digital tachometers Calibration — Speed Internal procedure; Direct method Contact method; At permanent location (S) Speed Internal procedure Direct method Contact method At permanent location (S) LW-1/IN/203","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Geschwindigkeit","parameters_de":[{"name":"","range":"10,00 rpm to 99,99 rpm","cmc":"0,1 U/min"},{"name":"","range":"100,0 rpm to 999,9 rpm","cmc":"0,2 U/min"},{"name":"","range":"100 0 rpm to 20000 rpm","cmc":"2 U/min"}],"regulatory_area_de":"Geschwindigkeit","search_de":"Digitale Drehzahlmesser Kalibrierung — Geschwindigkeit Interne Verfahrensanweisung; Direktes Verfahren Taktiles Verfahren; Am festen Standort (S) Geschwindigkeit Internes Verfahren Direktes Verfahren Taktiles Verfahren Am festen Standort (S) LW-1/IN/203","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren\nTaktiles Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren\nTaktiles Verfahren","Am festen Standort (S)"],"test_object_de":"Digitale Drehzahlmesser","methodology_zh":"校准 — 速度","parameters_zh":[{"name":"","range":"10,00 rpm to 99,99 rpm","cmc":"0,1 转/分"},{"name":"","range":"100,0 rpm to 999,9 rpm","cmc":"0,2 r/min"},{"name":"","range":"100 0 rpm to 20000 rpm","cmc":"2 r/min"}],"regulatory_area_zh":"速度","search_zh":"数字转速表 校准 — 速度 内部程序；直接法 接触法; 在固定地点 (S) 速度 内部程序 直接法 接触法 在固定地点 (S) LW-1/IN/203","technique_zh":"内部程序；直接法\n接触法; 在固定地点 (S)","techniques_zh":["内部程序","直接法\n接触法","在固定地点 (S)"],"test_object_zh":"数字转速表","methodology_cs":"Kalibrace — Rychlost","parameters_cs":[{"name":"","range":"10,00 rpm to 99,99 rpm","cmc":"0,1 ot./min"},{"name":"","range":"100,0 rpm to 999,9 rpm","cmc":"0,2 ot/min"},{"name":"","range":"100 0 rpm to 20000 rpm","cmc":"2 ot/min"}],"regulatory_area_cs":"Rychlost","search_cs":"Digitální otáčkoměry Kalibrace — Rychlost Vnitřní postup; Přímá metoda Dotyková metoda; Ve stálé lokalitě (S) Rychlost Vnitřní postup Přímá metoda Dotyková metoda Ve stálé lokalitě (S) LW-1/IN/203","technique_cs":"Vnitřní postup; Přímá metoda\nDotyková metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda\nDotyková metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální otáčkoměry"},{"_id":"a4acb1d96353486c82b223d6","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Tachometry cyfrowe","test_object_en":"Digital tachometers","methodology":"Wzorcowanie — Prędkość","methodology_en":"Calibration — Speed","parameters":[{"name":"","range":"0,89 m/min do 5,00 m/min","cmc":"0,02 m/min"},{"name":"","range":"5,01 m/min do 300,0 m/min","cmc":"0,3 %"}],"parameters_en":[{"name":"","range":"0,89 mpm to 5,00 mpm","cmc":"0,02 mpm"},{"name":"","range":"5,01 mpm to 300,0 mpm","cmc":"0,3 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prędkość\nZakres:\n0,89 m/min do 5,00 m/min CMC 0,02 m/min\n5,01 m/min do 300,0 m/min CMC 0,3 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/203","norm_bases":["LW-1/IN/203"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prędkość","regulatory_area_en":"Speed","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Tachometry cyfrowe Wzorcowanie — Prędkość\nZakres:\n0,89 m/min do 5,00 m/min CMC 0,02 m/min\n5,01 m/min do 300,0 m/min CMC 0,3 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/203 Tachometry cyfrowe Wzorcowanie — Predkosc\nZakres:\n0,89 m/min do 5,00 m/min CMC 0,02 m/min\n5,01 m/min do 300,0 m/min CMC 0,3 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/203","search_en":"Digital tachometers Calibration — Speed Internal procedure; Direct method; At permanent location (S) Speed Internal procedure Direct method At permanent location (S) LW-1/IN/203","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Geschwindigkeit","parameters_de":[{"name":"","range":"0,89 mpm to 5,00 mpm","cmc":"0,02 m/min"},{"name":"","range":"5,01 mpm to 300,0 mpm","cmc":"0,3 %"}],"regulatory_area_de":"Geschwindigkeit","search_de":"Digitale Drehzahlmesser Kalibrierung — Geschwindigkeit Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Geschwindigkeit Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/203","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Digitale Drehzahlmesser","methodology_zh":"校准 — 速度","parameters_zh":[{"name":"","range":"0,89 mpm to 5,00 mpm","cmc":"0,02 m/min"},{"name":"","range":"5,01 mpm to 300,0 mpm","cmc":"0,3 %"}],"regulatory_area_zh":"速度","search_zh":"数字转速表 校准 — 速度 内部程序；直接法；在固定地点 (S) 速度 内部程序 直接法 在固定地点 (S) LW-1/IN/203","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"数字转速表","methodology_cs":"Kalibrace — Rychlost","parameters_cs":[{"name":"","range":"0,89 mpm to 5,00 mpm","cmc":"0,02 m/min"},{"name":"","range":"5,01 mpm to 300,0 mpm","cmc":"0,3 %"}],"regulatory_area_cs":"Rychlost","search_cs":"Digitální otáčkoměry Kalibrace — Rychlost Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Rychlost Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/203","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální otáčkoměry"},{"_id":"44c557b68445403c2374767a","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Czujniki cyfrowe przemieszczenia","test_object_en":"Digital displacement sensors / transducers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 150 mm","cmc":"0,06 mm"}],"parameters_en":[{"name":"","range":"0 mm to 150 mm","cmc":"0,06 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia przy użyciu płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 150 mm CMC 0,06 mm\nProcedura wewnętrzna; Metoda bezpośrednia przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","reference":"LW-1/IN/202","norm_bases":["LW-1/IN/202"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe przemieszczenia Wzorcowanie — Długość\n0 mm do 150 mm CMC 0,06 mm\nProcedura wewnętrzna; Metoda bezpośrednia przy użyciu płytek wzorcowych; W stałej lokalizacji (S) LW-1/IN/202 Czujniki cyfrowe przemieszczenia Wzorcowanie — Dlugosc\n0 mm do 150 mm CMC 0,06 mm\nProcedura wewnetrzna; Metoda bezposrednia przy uzyciu plytek wzorcowych; W stalej lokalizacji (S) LW-1/IN/202","search_en":"Digital displacement sensors / transducers Calibration — Length Internal procedure; Direct method using a gauge blocks; At permanent location (S) Length Internal procedure Direct method using a gauge blocks At permanent location (S) LW-1/IN/202","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 150 mm","cmc":"0,06 mm"}],"regulatory_area_de":"Länge","search_de":"Digitale Wegaufnehmer Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) LW-1/IN/202","technique_de":"Internes Verfahren; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Digitale Wegaufnehmer","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 150 mm","cmc":"0,06 mm"}],"regulatory_area_zh":"长度","search_zh":"数字位移传感器 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) LW-1/IN/202","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"数字位移传感器","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 150 mm","cmc":"0,06 mm"}],"regulatory_area_cs":"Délka","search_cs":"Digitální snímače posunutí Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) LW-1/IN/202","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální snímače posunutí"},{"_id":"a61a9a6c7265606b947ea8a9","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Czujniki cyfrowe przemieszczenia","test_object_en":"Digital displacement sensors / transducers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 3,5 mm","cmc":"0,005 mm"},{"name":"","range":"3,5 mm do 500 mm","cmc":"0,15 %"}],"parameters_en":[{"name":"","range":"0 mm to 3,5 mm","cmc":"0,005 mm"},{"name":"","range":"3,5 mm to 500 mm","cmc":"0,15 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia przy użyciu interferometru; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using an interferometer; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia przy użyciu interferometru","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using an interferometer","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 3,5 mm CMC 0,005 mm\n3,5 mm do 500 mm CMC 0,15 %\nProcedura wewnętrzna; Metoda bezpośrednia przy użyciu interferometru; W stałej lokalizacji (S)","reference":"LW-1/IN/202","norm_bases":["LW-1/IN/202"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe przemieszczenia Wzorcowanie — Długość\nZakres:\n0 mm do 3,5 mm CMC 0,005 mm\n3,5 mm do 500 mm CMC 0,15 %\nProcedura wewnętrzna; Metoda bezpośrednia przy użyciu interferometru; W stałej lokalizacji (S) LW-1/IN/202 Czujniki cyfrowe przemieszczenia Wzorcowanie — Dlugosc\nZakres:\n0 mm do 3,5 mm CMC 0,005 mm\n3,5 mm do 500 mm CMC 0,15 %\nProcedura wewnetrzna; Metoda bezposrednia przy uzyciu interferometru; W stalej lokalizacji (S) LW-1/IN/202","search_en":"Digital displacement sensors / transducers Calibration — Length Internal procedure; Direct method using an interferometer; At permanent location (S) Length Internal procedure Direct method using an interferometer At permanent location (S) LW-1/IN/202","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 3,5 mm","cmc":"0,005 mm"},{"name":"","range":"3,5 mm to 500 mm","cmc":"0,15 %"}],"regulatory_area_de":"Länge","search_de":"Digitale Wegaufnehmer Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Interferometer; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Interferometer Am festen Standort (S) LW-1/IN/202","technique_de":"Internes Verfahren; Direktes Verfahren mit Interferometer; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Interferometer","Am festen Standort (S)"],"test_object_de":"Digitale Wegaufnehmer","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 3,5 mm","cmc":"0,005 mm"},{"name":"","range":"3,5 mm to 500 mm","cmc":"0,15 %"}],"regulatory_area_zh":"长度","search_zh":"数字位移传感器 校准 — 长度 内部程序; 使用干涉仪的直接法; 在固定地点 (S) 长度 内部程序 使用干涉仪的直接法 在固定地点 (S) LW-1/IN/202","technique_zh":"内部程序; 使用干涉仪的直接法; 在固定地点 (S)","techniques_zh":["内部程序","使用干涉仪的直接法","在固定地点 (S)"],"test_object_zh":"数字位移传感器","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 3,5 mm","cmc":"0,005 mm"},{"name":"","range":"3,5 mm to 500 mm","cmc":"0,15 %"}],"regulatory_area_cs":"Délka","search_cs":"Digitální snímače posunutí Kalibrace — Délka Vnitřní postup; Přímá metoda pomocí interferometru; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda pomocí interferometru Ve stálé lokalitě (S) LW-1/IN/202","technique_cs":"Vnitřní postup; Přímá metoda pomocí interferometru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda pomocí interferometru","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální snímače posunutí"},{"_id":"a1b457c346b83a0ca26c0a60","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Dalmierze laserowe","test_object_en":"Laser distance meters","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 m do 5 m","cmc":"1,0 mm"},{"name":"","range":"5,001 m do 30 m","cmc":"2,5 mm"},{"name":"","range":"30,0001 m do 50 m","cmc":"2,8 mm"}],"parameters_en":[{"name":"","range":"0 m to 5 m","cmc":"1,0 mm"},{"name":"","range":"5,001 m do 30 m","cmc":"2,5 mm"},{"name":"","range":"30,0001 m do 50 m","cmc":"2,8 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 m do 5 m CMC 1,0 mm\n5,001 m do 30 m CMC 2,5 mm\n30,0001 m do 50 m CMC 2,8 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/205","norm_bases":["LW-1/IN/205"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Dalmierze laserowe Wzorcowanie — Długość\nZakres:\n0 m do 5 m CMC 1,0 mm\n5,001 m do 30 m CMC 2,5 mm\n30,0001 m do 50 m CMC 2,8 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/205 Dalmierze laserowe Wzorcowanie — Dlugosc\nZakres:\n0 m do 5 m CMC 1,0 mm\n5,001 m do 30 m CMC 2,5 mm\n30,0001 m do 50 m CMC 2,8 mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/205","search_en":"Laser distance meters Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) LW-1/IN/205","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 m bis 5 m","cmc":"1,0 mm"},{"name":"","range":"5,001 m do 30 m","cmc":"2,5 mm"},{"name":"","range":"30,0001 m do 50 m","cmc":"2,8 mm"}],"regulatory_area_de":"Länge","search_de":"Laserentfernungsmesser Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/205","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Laserentfernungsmesser","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 m 至 5 m","cmc":"1,0 mm"},{"name":"","range":"5,001 m do 30 m","cmc":"2,5 mm"},{"name":"","range":"30,0001 m do 50 m","cmc":"2,8 mm"}],"regulatory_area_zh":"长度","search_zh":"激光测距仪 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) LW-1/IN/205","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"激光测距仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 m do 5 m","cmc":"1,0 mm"},{"name":"","range":"5,001 m do 30 m","cmc":"2,5 mm"},{"name":"","range":"30,0001 m do 50 m","cmc":"2,8 mm"}],"regulatory_area_cs":"Délka","search_cs":"Laserové dálkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/205","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Laserové dálkoměry"},{"_id":"6b251385569eb735be161065","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Głębokościomierze suwmiarkowe","test_object_en":"Caliper depth gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 150 mm","cmc":"0,06 mm"}],"parameters_en":[{"name":"","range":"0 mm to 150 mm","cmc":"0,06 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 150 mm CMC 0,06 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/202","norm_bases":["LW-1/IN/202"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze suwmiarkowe Wzorcowanie — Długość\n0 mm do 150 mm CMC 0,06 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/202 Glebokosciomierze suwmiarkowe Wzorcowanie — Dlugosc\n0 mm do 150 mm CMC 0,06 mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/202","search_en":"Caliper depth gauges Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) LW-1/IN/202","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 150 mm","cmc":"0,06 mm"}],"regulatory_area_de":"Länge","search_de":"Tiefenmessschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/202","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Tiefenmessschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 150 mm","cmc":"0,06 mm"}],"regulatory_area_zh":"长度","search_zh":"深度游标卡尺 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) LW-1/IN/202","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"深度游标卡尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 150 mm","cmc":"0,06 mm"}],"regulatory_area_cs":"Délka","search_cs":"Posuvné hloubkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/202","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Posuvné hloubkoměry"},{"_id":"f7d8315f1553c02e045b3226","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Grubościomierze ultradźwiękowe","test_object_en":"Ultrasonic thickness gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 2 mm","cmc":"0,01 mm"},{"name":"","range":"2 mm do 6 mm","cmc":"0,02 mm"},{"name":"","range":"6 mm do 100 mm","cmc":"0,3 %"}],"parameters_en":[{"name":"","range":"0 mm to 2 mm","cmc":"0,01 mm"},{"name":"","range":"2 mm to 6 mm","cmc":"0,02 mm"},{"name":"","range":"6 mm to 100 mm","cmc":"0,3 %"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 2 mm CMC 0,01 mm\n2 mm do 6 mm CMC 0,02 mm\n6 mm do 100 mm CMC 0,3 %\nW stałej lokalizacji (S)","reference":"PN-EN ISO 16831:2025-11 Testy grupy 2 pkt. 9.3, 9.13","norm_bases":["PN-EN ISO 16831:2025-11"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Grubościomierze ultradźwiękowe Wzorcowanie — Długość\nZakres:\n0 mm do 2 mm CMC 0,01 mm\n2 mm do 6 mm CMC 0,02 mm\n6 mm do 100 mm CMC 0,3 %\nW stałej lokalizacji (S) PN-EN ISO 16831:2025-11 Testy grupy 2 pkt. 9.3, 9.13 Grubosciomierze ultradzwiekowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 2 mm CMC 0,01 mm\n2 mm do 6 mm CMC 0,02 mm\n6 mm do 100 mm CMC 0,3 %\nW stalej lokalizacji (S) PN-EN ISO 16831:2025-11 Testy grupy 2 pkt. 9.3, 9.13","search_en":"Ultrasonic thickness gauges Calibration — Length At permanent location (S) Length At permanent location (S) PN-EN ISO 16831:2025-11 Group 2 tests cl. 9.3, 9.13","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PN-EN ISO 16831:2025-11 Group 2 tests cl. 9.3, 9.13","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 2 mm","cmc":"0,01 mm"},{"name":"","range":"2 mm to 6 mm","cmc":"0,02 mm"},{"name":"","range":"6 mm to 100 mm","cmc":"0,3 %"}],"reference_de":"PN-EN ISO 16831:2025-11 Prüfungen der Gruppe 2 Abschn. 9.3, 9.13","regulatory_area_de":"Länge","search_de":"Ultraschall-Dickenmessgeräte Kalibrierung — Länge Am festen Standort (S) Länge Am festen Standort (S) PN-EN ISO 16831:2025-11 Prüfungen der Gruppe 2 Abschn. 9.3, 9.13","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Ultraschall-Dickenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 2 mm","cmc":"0,01 mm"},{"name":"","range":"2 mm to 6 mm","cmc":"0,02 mm"},{"name":"","range":"6 mm to 100 mm","cmc":"0,3 %"}],"reference_zh":"PN-EN ISO 16831:2025-11 第2组试验第9.3、9.13条","regulatory_area_zh":"长度","search_zh":"超声波测厚仪 校准 — 长度 在固定地点 (S) 长度 在固定地点 (S) PN-EN ISO 16831:2025-11 第2组试验第9.3、9.13条","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"超声波测厚仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 2 mm","cmc":"0,01 mm"},{"name":"","range":"2 mm to 6 mm","cmc":"0,02 mm"},{"name":"","range":"6 mm to 100 mm","cmc":"0,3 %"}],"reference_cs":"PN-EN ISO 16831:2025-11 Zkoušky skupiny 2 čl. 9.3, 9.13","regulatory_area_cs":"Délka","search_cs":"Ultrazvukové tloušťkoměry Kalibrace — Délka Ve stálé lokalitě (S) Délka Ve stálé lokalitě (S) PN-EN ISO 16831:2025-11 Zkoušky skupiny 2 čl. 9.3, 9.13","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Ultrazvukové tloušťkoměry"},{"_id":"66edc3770eab208942e4786b","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Macki czujnikowe","test_object_en":"Internal / External measuring gauge","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"0,005 mm"},{"name":"","range":"50 mm do 100 mm","cmc":"0,008 mm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"0,005 mm"},{"name":"","range":"50 mm do 100 mm","cmc":"0,008 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 0,005 mm\n50 mm do 100 mm CMC 0,008 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/202","norm_bases":["LW-1/IN/202"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Macki czujnikowe Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 0,005 mm\n50 mm do 100 mm CMC 0,008 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/202 Macki czujnikowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 50 mm CMC 0,005 mm\n50 mm do 100 mm CMC 0,008 mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/202","search_en":"Internal / External measuring gauge Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) LW-1/IN/202","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"0,005 mm"},{"name":"","range":"50 mm do 100 mm","cmc":"0,008 mm"}],"regulatory_area_de":"Länge","search_de":"Messuhr-Taster (Innen-/Außen) Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/202","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Messuhr-Taster (Innen-/Außen)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"0,005 mm"},{"name":"","range":"50 mm do 100 mm","cmc":"0,008 mm"}],"regulatory_area_zh":"长度","search_zh":"指示表式卡规 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) LW-1/IN/202","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"指示表式卡规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"0,005 mm"},{"name":"","range":"50 mm do 100 mm","cmc":"0,008 mm"}],"regulatory_area_cs":"Délka","search_cs":"Úchylkoměrné dutinoměry a třmeny Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/202","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Úchylkoměrné dutinoměry a třmeny"},{"_id":"ca717973d924fb48c72cf7f1","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Mierniki do pomiaru grubości powłok","test_object_en":"Coating thickness gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 0,5 mm","cmc":"0,003 mm"},{"name":"","range":"0,5 mm do 3 mm","cmc":"0,7 %"}],"parameters_en":[{"name":"","range":"0 mm to 0,5 mm","cmc":"0,003 mm"},{"name":"","range":"0,5 mm to 3 mm","cmc":"0,7 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 0,5 mm CMC 0,003 mm\n0,5 mm do 3 mm CMC 0,7 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/210","norm_bases":["LW-1/IN/210"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki do pomiaru grubości powłok Wzorcowanie — Długość\nZakres:\n0 mm do 0,5 mm CMC 0,003 mm\n0,5 mm do 3 mm CMC 0,7 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/210 Mierniki do pomiaru grubosci powlok Wzorcowanie — Dlugosc\nZakres:\n0 mm do 0,5 mm CMC 0,003 mm\n0,5 mm do 3 mm CMC 0,7 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/210","search_en":"Coating thickness gauges Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) LW-1/IN/210","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 0,5 mm","cmc":"0,003 mm"},{"name":"","range":"0,5 mm to 3 mm","cmc":"0,7 %"}],"regulatory_area_de":"Länge","search_de":"Schichtdickenmessgeräte Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/210","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Schichtdickenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 0,5 mm","cmc":"0,003 mm"},{"name":"","range":"0,5 mm to 3 mm","cmc":"0,7 %"}],"regulatory_area_zh":"长度","search_zh":"涂层测厚仪 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) LW-1/IN/210","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"涂层测厚仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 0,5 mm","cmc":"0,003 mm"},{"name":"","range":"0,5 mm to 3 mm","cmc":"0,7 %"}],"regulatory_area_cs":"Délka","search_cs":"Měřidla tloušťky povlaků Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/210","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřidla tloušťky povlaků"},{"_id":"2ec139a3a652fbb45ad311fd","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Przymiary wstęgowe","test_object_en":"Tape measures","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 m do 60 m","cmc":"0,2 mm + 0,2 · (n – 1) mm"}],"parameters_en":[{"name":"","range":"0 m to 60 m","cmc":"0,2 mm + 0,2 · (n – 1) mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 m do 60 m CMC 0,2 mm + 0,2 · (n – 1) mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/205","norm_bases":["LW-1/IN/205"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"n – liczba odcinków 5-metrowych","note_en":"n – number of 5-meter sections","search_text":"Przymiary wstęgowe Wzorcowanie — Długość\n0 m do 60 m CMC 0,2 mm + 0,2 · (n – 1) mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/205 Przymiary wstegowe Wzorcowanie — Dlugosc\n0 m do 60 m CMC 0,2 mm + 0,2 · (n – 1) mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/205","search_en":"Tape measures Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) LW-1/IN/205","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 m to 60 m","cmc":"0,2 mm + 0,2 · (n – 1) mm"}],"regulatory_area_de":"Länge","search_de":"Bandmaße Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/205","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Bandmaße","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 m to 60 m","cmc":"0,2 mm + 0,2 · (n – 1) mm"}],"regulatory_area_zh":"长度","search_zh":"卷尺 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) LW-1/IN/205","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"卷尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 m to 60 m","cmc":"0,2 mm + 0,2 · (n – 1) mm"}],"regulatory_area_cs":"Délka","search_cs":"Měřicí pásma Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/205","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřicí pásma"},{"_id":"df9e56bdc927eca5e133e5c0","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Przymiary półsztywne\nŚrednicówki taśmowe","test_object_en":"Semi-rigid rules\nCircometer (diameter tapes)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 m do 5 m","cmc":"0,2 mm"}],"parameters_en":[{"name":"","range":"0 m to 5 m","cmc":"0,2 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 m do 5 m CMC 0,2 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/205","norm_bases":["LW-1/IN/205"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przymiary półsztywne\nŚrednicówki taśmowe Wzorcowanie — Długość\n0 m do 5 m CMC 0,2 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/205 Przymiary polsztywne\nSrednicowki tasmowe Wzorcowanie — Dlugosc\n0 m do 5 m CMC 0,2 mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/205","search_en":"Semi-rigid rules Circometer (diameter tapes) Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) LW-1/IN/205","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 m bis 5 m","cmc":"0,2 mm"}],"regulatory_area_de":"Länge","search_de":"Halbstarre Maßstäbe Umfangsmaßbänder Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/205","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Halbstarre Maßstäbe\nUmfangsmaßbänder","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 m 至 5 m","cmc":"0,2 mm"}],"regulatory_area_zh":"长度","search_zh":"半刚性量尺 围尺 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) LW-1/IN/205","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"半刚性量尺\n围尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 m do 5 m","cmc":"0,2 mm"}],"regulatory_area_cs":"Délka","search_cs":"Polotuhá délková měřidla Pásková průměrová měřidla Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/205","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Polotuhá délková měřidla\nPásková průměrová měřidla"},{"_id":"b62a8cc9be87f5cde6b9b2e3","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Spoinomierze","test_object_en":"Weld gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 35 mm","cmc":"0,06 mm"}],"parameters_en":[{"name":"","range":"0 mm to 35 mm","cmc":"0,06 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 35 mm CMC 0,06 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/202","norm_bases":["LW-1/IN/202"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Spoinomierze Wzorcowanie — Długość\n0 mm do 35 mm CMC 0,06 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/202 Spoinomierze Wzorcowanie — Dlugosc\n0 mm do 35 mm CMC 0,06 mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/202","search_en":"Weld gauges Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) LW-1/IN/202","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 35 mm","cmc":"0,06 mm"}],"regulatory_area_de":"Länge","search_de":"Schweißnahtlehren Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/202","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Schweißnahtlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 35 mm","cmc":"0,06 mm"}],"regulatory_area_zh":"长度","search_zh":"焊缝量规 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) LW-1/IN/202","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"焊缝量规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 35 mm","cmc":"0,06 mm"}],"regulatory_area_cs":"Délka","search_cs":"Svarové měrky Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/202","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Svarové měrky"},{"_id":"b704b25d5fc193b5b7545563","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Suwmiarki","test_object_en":"Calipers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 500 mm","cmc":"0,06 mm"}],"parameters_en":[{"name":"","range":"0 mm to 500 mm","cmc":"0,06 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 500 mm CMC 0,06 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/202","norm_bases":["LW-1/IN/202"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Suwmiarki Wzorcowanie — Długość\n0 mm do 500 mm CMC 0,06 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/202 Suwmiarki Wzorcowanie — Dlugosc\n0 mm do 500 mm CMC 0,06 mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/202","search_en":"Calipers Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) LW-1/IN/202","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 500 mm","cmc":"0,06 mm"}],"regulatory_area_de":"Länge","search_de":"Messschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/202","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Messschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 500 mm","cmc":"0,06 mm"}],"regulatory_area_zh":"长度","search_zh":"游标卡尺 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) LW-1/IN/202","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"游标卡尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 500 mm","cmc":"0,06 mm"}],"regulatory_area_cs":"Délka","search_cs":"Posuvná měřidla Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/202","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Posuvná měřidla"},{"_id":"d11a1c221a26772dda533ecc","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Szczelinomierze","test_object_en":"Feeler gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,05 mm do 2 mm","cmc":"0,007 mm"}],"parameters_en":[{"name":"","range":"0,05 mm to 2 mm","cmc":"0,007 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,05 mm do 2 mm CMC 0,007 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/209","norm_bases":["LW-1/IN/209"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Szczelinomierze Wzorcowanie — Długość\n0,05 mm do 2 mm CMC 0,007 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/209 Szczelinomierze Wzorcowanie — Dlugosc\n0,05 mm do 2 mm CMC 0,007 mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/209","search_en":"Feeler gauges Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) LW-1/IN/209","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,05 mm to 2 mm","cmc":"0,007 mm"}],"regulatory_area_de":"Länge","search_de":"Fühlerlehren Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/209","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Fühlerlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,05 mm to 2 mm","cmc":"0,007 mm"}],"regulatory_area_zh":"长度","search_zh":"塞尺 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) LW-1/IN/209","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"塞尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,05 mm to 2 mm","cmc":"0,007 mm"}],"regulatory_area_cs":"Délka","search_cs":"Spároměry Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/209","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Spároměry"},{"_id":"bbe6db6384cacb5e007b674d","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Wzorce schodkowe do grubościomierzy ultradźwiękowych","test_object_en":"Step wedges (calibration blocks) for ultrasonic thickness gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,5 mm do 25 mm","cmc":"0,007 mm"}],"parameters_en":[{"name":"","range":"0,5 mm to 25 mm","cmc":"0,007 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,5 mm do 25 mm CMC 0,007 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/209","norm_bases":["LW-1/IN/209"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce schodkowe do grubościomierzy ultradźwiękowych Wzorcowanie — Długość\n0,5 mm do 25 mm CMC 0,007 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/209 Wzorce schodkowe do grubosciomierzy ultradzwiekowych Wzorcowanie — Dlugosc\n0,5 mm do 25 mm CMC 0,007 mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/209","search_en":"Step wedges (calibration blocks) for ultrasonic thickness gauges Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) LW-1/IN/209","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,5 mm to 25 mm","cmc":"0,007 mm"}],"regulatory_area_de":"Länge","search_de":"Stufenkörper für Ultraschall-Dickenmessgeräte Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/209","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Stufenkörper für Ultraschall-Dickenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,5 mm to 25 mm","cmc":"0,007 mm"}],"regulatory_area_zh":"长度","search_zh":"超声测厚仪用阶梯试块 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) LW-1/IN/209","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"超声测厚仪用阶梯试块","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,5 mm to 25 mm","cmc":"0,007 mm"}],"regulatory_area_cs":"Délka","search_cs":"Stupňové etalony pro ultrazvukové tloušťkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/209","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Stupňové etalony pro ultrazvukové tloušťkoměry"},{"_id":"ac6cd5aac96fe4dbfa5834a2","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Ekstensometry","test_object_en":"Extensometers","methodology":"Wzorcowanie — Siła","methodology_en":"Calibration — Force","parameters":[{"name":"","range":"0 mm do 0,35 mm","cmc":"0,5 µm"},{"name":"","range":"0,35 do 2500 mm","cmc":"0,15 %"}],"parameters_en":[{"name":"","range":"0 mm to 0,35 mm","cmc":"0,5 µm"},{"name":"","range":"0,35 to 2500 mm","cmc":"0,15 %"}],"technique":"W stałej lokalizacji (S) i poza nią (P)","technique_en":"At permanent location (S) and outside of it (P)","techniques":["W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Siła\nZakres:\n0 mm do 0,35 mm CMC 0,5 µm\n0,35 do 2500 mm CMC 0,15 %\nW stałej lokalizacji (S) i poza nią (P)","reference":"PN-EN ISO 9513:2013-06\nASTM E83-25","norm_bases":["PN-EN ISO 9513:2013-06","ASTM E83-25"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Siła","regulatory_area_en":"Force","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Ekstensometry Wzorcowanie — Siła\nZakres:\n0 mm do 0,35 mm CMC 0,5 µm\n0,35 do 2500 mm CMC 0,15 %\nW stałej lokalizacji (S) i poza nią (P) PN-EN ISO 9513:2013-06\nASTM E83-25 Ekstensometry Wzorcowanie — Sila\nZakres:\n0 mm do 0,35 mm CMC 0,5 µm\n0,35 do 2500 mm CMC 0,15 %\nW stalej lokalizacji (S) i poza nia (P) PN-EN ISO 9513:2013-06\nASTM E83-25","search_en":"Extensometers Calibration — Force At permanent location (S) and outside of it (P) Force At permanent location (S) and outside of it (P) PN-EN ISO 9513:2013-06 ASTM E83-25","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Kraft","parameters_de":[{"name":"","range":"0 mm to 0,35 mm","cmc":"0,5 µm"},{"name":"","range":"0,35 to 2500 mm","cmc":"0,15 %"}],"regulatory_area_de":"Kraft","search_de":"Extensometer Kalibrierung — Kraft Am festen Standort (S) und außerhalb (P) Kraft Am festen Standort (S) und außerhalb (P) PN-EN ISO 9513:2013-06 ASTM E83-25","technique_de":"Am festen Standort (S) und außerhalb (P)","techniques_de":["Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Extensometer","methodology_zh":"校准 — 力","parameters_zh":[{"name":"","range":"0 mm to 0,35 mm","cmc":"0,5 µm"},{"name":"","range":"0,35 to 2500 mm","cmc":"0,15 %"}],"regulatory_area_zh":"力","search_zh":"引伸计 校准 — 力 在固定地点 (S) 及固定地点以外 (P) 力 在固定地点 (S) 及固定地点以外 (P) PN-EN ISO 9513:2013-06 ASTM E83-25","technique_zh":"在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"引伸计","methodology_cs":"Kalibrace — Síla","parameters_cs":[{"name":"","range":"0 mm to 0,35 mm","cmc":"0,5 µm"},{"name":"","range":"0,35 to 2500 mm","cmc":"0,15 %"}],"regulatory_area_cs":"Síla","search_cs":"Extenzometry Kalibrace — Síla V trvalé lokalitě (S) i mimo ni (P) Síla V trvalé lokalitě (S) i mimo ni (P) PN-EN ISO 9513:2013-06 ASTM E83-25","technique_cs":"V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Extenzometry"},{"_id":"c43b9200df322147734f79a2","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Maszyny wytrzymałościowe do prób statycznych\nUrządzenia technologiczne\n- do sił rozciągających\n- do sił ściskających","test_object_en":"Universal Testing Machines\nTechnological devices\n- for tensile forces\n- for compressive forces","methodology":"Wzorcowanie — Siła","methodology_en":"Calibration — Force","parameters":[{"name":"","range":"0,5 N do 250 kN","cmc":"0,13 %"}],"parameters_en":[{"name":"","range":"0,5 N to 250 kN","cmc":"0,13 %"}],"technique":"W stałej lokalizacji (S) i poza nią (P)","technique_en":"At permanent location (S) and outside of it (P)","techniques":["W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Siła\n0,5 N do 250 kN CMC 0,13 %\nW stałej lokalizacji (S) i poza nią (P)","reference":"PN-EN ISO 7500-1:2018-05\nASTM E4-24","norm_bases":["PN-EN ISO 7500-1:2018-05","ASTM E4-24"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Siła","regulatory_area_en":"Force","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Maszyny wytrzymałościowe do prób statycznych\nUrządzenia technologiczne\n- do sił rozciągających\n- do sił ściskających Wzorcowanie — Siła\n0,5 N do 250 kN CMC 0,13 %\nW stałej lokalizacji (S) i poza nią (P) PN-EN ISO 7500-1:2018-05\nASTM E4-24 Maszyny wytrzymalosciowe do prob statycznych\nUrzadzenia technologiczne\n- do sil rozciagajacych\n- do sil sciskajacych Wzorcowanie — Sila\n0,5 N do 250 kN CMC 0,13 %\nW stalej lokalizacji (S) i poza nia (P) PN-EN ISO 7500-1:2018-05\nASTM E4-24","search_en":"Universal Testing Machines Technological devices - for tensile forces - for compressive forces Calibration — Force At permanent location (S) and outside of it (P) Force At permanent location (S) and outside of it (P) PN-EN ISO 7500-1:2018-05 ASTM E4-24","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Kraft","parameters_de":[{"name":"","range":"0,5 N to 250 kN","cmc":"0,13 %"}],"regulatory_area_de":"Kraft","search_de":"Statische Werkstoffprüfmaschinen Technologische Einrichtungen - für Zugkräfte - für Druckkräfte Kalibrierung — Kraft Am festen Standort (S) und außerhalb (P) Kraft Am festen Standort (S) und außerhalb (P) PN-EN ISO 7500-1:2018-05 ASTM E4-24","technique_de":"Am festen Standort (S) und außerhalb (P)","techniques_de":["Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Statische Werkstoffprüfmaschinen\nTechnologische Einrichtungen\n- für Zugkräfte\n- für Druckkräfte","methodology_zh":"校准 — 力","parameters_zh":[{"name":"","range":"0,5 N to 250 kN","cmc":"0,13 %"}],"regulatory_area_zh":"力","search_zh":"静态材料试验机 工艺设备 - 用于拉力 - 用于压力 校准 — 力 在固定地点 (S) 及固定地点以外 (P) 力 在固定地点 (S) 及固定地点以外 (P) PN-EN ISO 7500-1:2018-05 ASTM E4-24","technique_zh":"在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"静态材料试验机\n工艺设备\n- 用于拉力\n- 用于压力","methodology_cs":"Kalibrace — Síla","parameters_cs":[{"name":"","range":"0,5 N to 250 kN","cmc":"0,13 %"}],"regulatory_area_cs":"Síla","search_cs":"Trhací stroje pro statické zkoušky Technologická zařízení - pro tahové síly - pro tlakové síly Kalibrace — Síla V trvalé lokalitě (S) i mimo ni (P) Síla V trvalé lokalitě (S) i mimo ni (P) PN-EN ISO 7500-1:2018-05 ASTM E4-24","technique_cs":"V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Trhací stroje pro statické zkoušky\nTechnologická zařízení\n- pro tahové síly\n- pro tlakové síly"},{"_id":"c7ca5de1dafb7fa9e6f6ce60","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Maszyny wytrzymałościowe do prób statycznych\nUrządzenia technologiczne\n- przemieszczenie (droga) trawersy","test_object_en":"Universal Testing Machines\nTechnological devices\n- Crosshead Displacement or Actuator Stroke","methodology":"Wzorcowanie — Siła","methodology_en":"Calibration — Force","parameters":[{"name":"","range":"0 mm do 0,35 mm","cmc":"0,5 µm"},{"name":"","range":"0,35 mm do 5000 mm","cmc":"0,15 %"}],"parameters_en":[{"name":"","range":"0 mm to 0,35 mm","cmc":"0,5 µm"},{"name":"","range":"0,35 mm to 5000 mm","cmc":"0,15 %"}],"technique":"W stałej lokalizacji (S) i poza nią (P)","technique_en":"At permanent location (S) and outside of it (P)","techniques":["W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Siła\nZakres:\n0 mm do 0,35 mm CMC 0,5 µm\n0,35 mm do 5000 mm CMC 0,15 %\nW stałej lokalizacji (S) i poza nią (P)","reference":"PN-EN ISO 9513:2013-06 Załącznik H\nASTM E2309/E2309M-2","norm_bases":["PN-EN ISO 9513:2013-06 Załącznik H","ASTM E2309/E2309M-2"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Siła","regulatory_area_en":"Force","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Maszyny wytrzymałościowe do prób statycznych\nUrządzenia technologiczne\n- przemieszczenie (droga) trawersy Wzorcowanie — Siła\nZakres:\n0 mm do 0,35 mm CMC 0,5 µm\n0,35 mm do 5000 mm CMC 0,15 %\nW stałej lokalizacji (S) i poza nią (P) PN-EN ISO 9513:2013-06 Załącznik H\nASTM E2309/E2309M-2 Maszyny wytrzymalosciowe do prob statycznych\nUrzadzenia technologiczne\n- przemieszczenie (droga) trawersy Wzorcowanie — Sila\nZakres:\n0 mm do 0,35 mm CMC 0,5 µm\n0,35 mm do 5000 mm CMC 0,15 %\nW stalej lokalizacji (S) i poza nia (P) PN-EN ISO 9513:2013-06 Zalacznik H\nASTM E2309/E2309M-2","search_en":"Universal Testing Machines Technological devices - Crosshead Displacement or Actuator Stroke Calibration — Force At permanent location (S) and outside of it (P) Force At permanent location (S) and outside of it (P) PN-EN ISO 9513:2013-06 Annex H ASTM E2309/E2309M-2","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PN-EN ISO 9513:2013-06 Annex H\nASTM E2309/E2309M-2","methodology_de":"Kalibrierung — Kraft","parameters_de":[{"name":"","range":"0 mm to 0,35 mm","cmc":"0,5 µm"},{"name":"","range":"0,35 mm to 5000 mm","cmc":"0,15 %"}],"reference_de":"PN-EN ISO 9513:2013-06 Anhang H\nASTM E2309/E2309M-2","regulatory_area_de":"Kraft","search_de":"Statische Werkstoffprüfmaschinen Technologische Einrichtungen - Traversenverschiebung (Weg) Kalibrierung — Kraft Am festen Standort (S) und außerhalb (P) Kraft Am festen Standort (S) und außerhalb (P) PN-EN ISO 9513:2013-06 Anhang H ASTM E2309/E2309M-2","technique_de":"Am festen Standort (S) und außerhalb (P)","techniques_de":["Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Statische Werkstoffprüfmaschinen\nTechnologische Einrichtungen\n- Traversenverschiebung (Weg)","methodology_zh":"校准 — 力","parameters_zh":[{"name":"","range":"0 mm to 0,35 mm","cmc":"0,5 µm"},{"name":"","range":"0,35 mm to 5000 mm","cmc":"0,15 %"}],"reference_zh":"PN-EN ISO 9513:2013-06附录H\nASTM E2309/E2309M-2","regulatory_area_zh":"力","search_zh":"静态材料试验机 工艺设备 - 横梁位移（行程） 校准 — 力 在固定地点 (S) 及固定地点以外 (P) 力 在固定地点 (S) 及固定地点以外 (P) PN-EN ISO 9513:2013-06附录H ASTM E2309/E2309M-2","technique_zh":"在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"静态材料试验机\n工艺设备\n- 横梁位移（行程）","methodology_cs":"Kalibrace — Síla","parameters_cs":[{"name":"","range":"0 mm to 0,35 mm","cmc":"0,5 µm"},{"name":"","range":"0,35 mm to 5000 mm","cmc":"0,15 %"}],"reference_cs":"PN-EN ISO 9513:2013-06 Příloha H\nASTM E2309/E2309M-2","regulatory_area_cs":"Síla","search_cs":"Trhací stroje pro statické zkoušky Technologická zařízení - posunutí (dráha) příčníku Kalibrace — Síla V trvalé lokalitě (S) i mimo ni (P) Síla V trvalé lokalitě (S) i mimo ni (P) PN-EN ISO 9513:2013-06 Příloha H ASTM E2309/E2309M-2","technique_cs":"V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Trhací stroje pro statické zkoušky\nTechnologická zařízení\n- posunutí (dráha) příčníku"},{"_id":"9ad6003697e02f036c52c34b","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Maszyny wytrzymałościowe do prób statycznych\nUrządzenia technologiczne\n- prędkość przemieszczenia trawersy","test_object_en":"Universal Testing Machines\nTechnological devices\n- Crosshead /Actuator Speed","methodology":"Wzorcowanie — Siła","methodology_en":"Calibration — Force","parameters":[{"name":"","range":"0 mm/min do 0,5 mm/min","cmc":"1 µm/min"},{"name":"","range":"0,5 mm/min do 3000 mm/min","cmc":"0,2 %"}],"parameters_en":[{"name":"","range":"0 mm/min to 0,5 mm/min","cmc":"1 µm/min"},{"name":"","range":"0,5 mm/min to 3000 mm/min","cmc":"0,2 %"}],"technique":"W stałej lokalizacji (S) i poza nią (P)","technique_en":"At permanent location (S) and outside of it (P)","techniques":["W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Siła\nZakres:\n0 mm/min do 0,5 mm/min CMC 1 µm/min\n0,5 mm/min do 3000 mm/min CMC 0,2 %\nW stałej lokalizacji (S) i poza nią (P)","reference":"ASTM E2658-15","norm_bases":["ASTM E2658-15"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Siła","regulatory_area_en":"Force","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Maszyny wytrzymałościowe do prób statycznych\nUrządzenia technologiczne\n- prędkość przemieszczenia trawersy Wzorcowanie — Siła\nZakres:\n0 mm/min do 0,5 mm/min CMC 1 µm/min\n0,5 mm/min do 3000 mm/min CMC 0,2 %\nW stałej lokalizacji (S) i poza nią (P) ASTM E2658-15 Maszyny wytrzymalosciowe do prob statycznych\nUrzadzenia technologiczne\n- predkosc przemieszczenia trawersy Wzorcowanie — Sila\nZakres:\n0 mm/min do 0,5 mm/min CMC 1 µm/min\n0,5 mm/min do 3000 mm/min CMC 0,2 %\nW stalej lokalizacji (S) i poza nia (P) ASTM E2658-15","search_en":"Universal Testing Machines Technological devices - Crosshead /Actuator Speed Calibration — Force At permanent location (S) and outside of it (P) Force At permanent location (S) and outside of it (P) ASTM E2658-15","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":19,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Kraft","parameters_de":[{"name":"","range":"0 mm/min to 0,5 mm/min","cmc":"1 µm/min"},{"name":"","range":"0,5 mm/min to 3000 mm/min","cmc":"0,2 %"}],"regulatory_area_de":"Kraft","search_de":"Statische Werkstoffprüfmaschinen Technologische Einrichtungen - Traversengeschwindigkeit Kalibrierung — Kraft Am festen Standort (S) und außerhalb (P) Kraft Am festen Standort (S) und außerhalb (P) ASTM E2658-15","technique_de":"Am festen Standort (S) und außerhalb (P)","techniques_de":["Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Statische Werkstoffprüfmaschinen\nTechnologische Einrichtungen\n- Traversengeschwindigkeit","methodology_zh":"校准 — 力","parameters_zh":[{"name":"","range":"0 mm/min to 0,5 mm/min","cmc":"1 µm/min"},{"name":"","range":"0,5 mm/min to 3000 mm/min","cmc":"0,2 %"}],"regulatory_area_zh":"力","search_zh":"静态材料试验机 工艺设备 - 横梁位移速度 校准 — 力 在固定地点 (S) 及固定地点以外 (P) 力 在固定地点 (S) 及固定地点以外 (P) ASTM E2658-15","technique_zh":"在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"静态材料试验机\n工艺设备\n- 横梁位移速度","methodology_cs":"Kalibrace — Síla","parameters_cs":[{"name":"","range":"0 mm/min to 0,5 mm/min","cmc":"1 µm/min"},{"name":"","range":"0,5 mm/min to 3000 mm/min","cmc":"0,2 %"}],"regulatory_area_cs":"Síla","search_cs":"Trhací stroje pro statické zkoušky Technologická zařízení - rychlost posuvu příčníku Kalibrace — Síla V trvalé lokalitě (S) i mimo ni (P) Síla V trvalé lokalitě (S) i mimo ni (P) ASTM E2658-15","technique_cs":"V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Trhací stroje pro statické zkoušky\nTechnologická zařízení\n- rychlost posuvu příčníku"},{"_id":"767227d5885f195b4a9a870b","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Siłomierze","test_object_en":"Force gauges","methodology":"Wzorcowanie — Siła","methodology_en":"Calibration — Force","parameters":[{"name":"","range":"0,5 N do 250 kN","cmc":"0,13 %"}],"parameters_en":[{"name":"","range":"0,5 N to 250 kN","cmc":"0,13 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Siła\n0,5 N do 250 kN CMC 0,13 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LW-1/IN/212 w oparciu o PN-EN ISO 7500-1:2018-05","norm_bases":["LW-1/IN/212","PN-EN ISO 7500-1:2018-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Siła","regulatory_area_en":"Force","outside_premises":true,"location_of_activity":"S, P","note":"W kolumnie miejsca działalności zapisano „S, P” i „S”.","note_en":"The location of activity column reads “S, P” and “S”.","search_text":"Siłomierze Wzorcowanie — Siła\n0,5 N do 250 kN CMC 0,13 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LW-1/IN/212 w oparciu o PN-EN ISO 7500-1:2018-05 Silomierze Wzorcowanie — Sila\n0,5 N do 250 kN CMC 0,13 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LW-1/IN/212 w oparciu o PN-EN ISO 7500-1:2018-05","search_en":"Force gauges Calibration — Force Internal procedure; Direct method; At permanent location (S) and outside of it (P) Force Internal procedure Direct method At permanent location (S) and outside of it (P) LW-1/IN/212 based on PN-EN ISO 7500-1:2018-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":20,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LW-1/IN/212 based on PN-EN ISO 7500-1:2018-05","methodology_de":"Kalibrierung — Kraft","parameters_de":[{"name":"","range":"0,5 N to 250 kN","cmc":"0,13 %"}],"reference_de":"LW-1/IN/212 auf Grundlage von PN-EN ISO 7500-1:2018-05","regulatory_area_de":"Kraft","search_de":"Kraftmessgeräte Kalibrierung — Kraft Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Kraft Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LW-1/IN/212 auf Grundlage von PN-EN ISO 7500-1:2018-05","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kraftmessgeräte","methodology_zh":"校准 — 力","parameters_zh":[{"name":"","range":"0,5 N to 250 kN","cmc":"0,13 %"}],"reference_zh":"LW-1/IN/212 依据PN-EN ISO 7500-1:2018-05","regulatory_area_zh":"力","search_zh":"测力仪 校准 — 力 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 力 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LW-1/IN/212 依据PN-EN ISO 7500-1:2018-05","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"测力仪","methodology_cs":"Kalibrace — Síla","parameters_cs":[{"name":"","range":"0,5 N to 250 kN","cmc":"0,13 %"}],"reference_cs":"LW-1/IN/212 na základě PN-EN ISO 7500-1:2018-05","regulatory_area_cs":"Síla","search_cs":"Siloměry Kalibrace — Síla Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Síla Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LW-1/IN/212 na základě PN-EN ISO 7500-1:2018-05","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Siloměry"},{"_id":"5ef775740e412fdfcf434933","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Twardościomierze przenośne","test_object_en":"Portable hardness testers","methodology":"Wzorcowanie — Twardość","methodology_en":"Calibration — Hardness","parameters":[{"name":"","range":"HV5","cmc":"3 %"},{"name":"","range":"HV10","cmc":"3 %"}],"parameters_en":[{"name":"","range":"HV5","cmc":"3 %"},{"name":"","range":"HV10","cmc":"3 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Twardość\nZakres:\nHV5 CMC 3 %\nHV10 CMC 3 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LW-1/IN/213 w oparciu o DIN 50159-2:2022-06\nPN-EN ISO 6507-2:2018-05","norm_bases":["LW-1/IN/213","DIN 50159-2:2022-06","PN-EN ISO 6507-2:2018-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Twardość","regulatory_area_en":"Hardness","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Twardościomierze przenośne Wzorcowanie — Twardość\nZakres:\nHV5 CMC 3 %\nHV10 CMC 3 %\nProcedura wewnętrzna; W stałej lokalizacji (S) LW-1/IN/213 w oparciu o DIN 50159-2:2022-06\nPN-EN ISO 6507-2:2018-05 Twardosciomierze przenosne Wzorcowanie — Twardosc\nZakres:\nHV5 CMC 3 %\nHV10 CMC 3 %\nProcedura wewnetrzna; W stalej lokalizacji (S) LW-1/IN/213 w oparciu o DIN 50159-2:2022-06\nPN-EN ISO 6507-2:2018-05","search_en":"Portable hardness testers Calibration — Hardness Internal procedure; At permanent location (S) Hardness Internal procedure At permanent location (S) LW-1/IN/213 based on DIN 50159-2:2022-06 PN-EN ISO 6507-2:2018-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":21,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LW-1/IN/213 based on DIN 50159-2:2022-06\nPN-EN ISO 6507-2:2018-05","methodology_de":"Kalibrierung — Härte","reference_de":"LW-1/IN/213 auf Grundlage von DIN 50159-2:2022-06\nPN-EN ISO 6507-2:2018-05","regulatory_area_de":"Härte","search_de":"Tragbare Härteprüfgeräte Kalibrierung — Härte Internes Verfahren; Am festen Standort (S) Härte Internes Verfahren Am festen Standort (S) LW-1/IN/213 auf Grundlage von DIN 50159-2:2022-06 PN-EN ISO 6507-2:2018-05","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Tragbare Härteprüfgeräte","methodology_zh":"校准 — 硬度","reference_zh":"LW-1/IN/213 依据DIN 50159-2:2022-06\nPN-EN ISO 6507-2:2018-05","regulatory_area_zh":"硬度","search_zh":"便携式硬度计 校准 — 硬度 内部程序；在固定地点 (S) 硬度 内部程序 在固定地点 (S) LW-1/IN/213 依据DIN 50159-2:2022-06 PN-EN ISO 6507-2:2018-05","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"便携式硬度计","methodology_cs":"Kalibrace — Tvrdost","reference_cs":"LW-1/IN/213 na základě DIN 50159-2:2022-06\nPN-EN ISO 6507-2:2018-05","regulatory_area_cs":"Tvrdost","search_cs":"Přenosné tvrdoměry Kalibrace — Tvrdost Vnitřní postup; Ve stálé lokalitě (S) Tvrdost Vnitřní postup Ve stálé lokalitě (S) LW-1/IN/213 na základě DIN 50159-2:2022-06 PN-EN ISO 6507-2:2018-05","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Přenosné tvrdoměry"},{"_id":"9ee3a16432bf8960b337d7ac","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Mierniki natężenia napromienienia UV-A do badań nieniszczących (NDT)","test_object_en":"UV-A irradiance meters for non-destructive testing (NDT)","methodology":"Wzorcowanie — Wielkości radiometryczne","methodology_en":"Calibration — Radiometric quantities","parameters":[{"name":"","range":"0,1 mW/cm² do 5 mW/cm²","cmc":"12 %"}],"parameters_en":[{"name":"","range":"0,1 mW/cm² to 5 mW/cm²","cmc":"12 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości radiometryczne\n0,1 mW/cm² do 5 mW/cm² CMC 12 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/207 w oparciu o CIE 220:2016","norm_bases":["LW-1/IN/207","CIE 220:2016"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości radiometryczne","regulatory_area_en":"Radiometric quantities","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki natężenia napromienienia UV-A do badań nieniszczących (NDT) Wzorcowanie — Wielkości radiometryczne\n0,1 mW/cm² do 5 mW/cm² CMC 12 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/207 w oparciu o CIE 220:2016 Mierniki natezenia napromienienia UV-A do badan nieniszczacych (NDT) Wzorcowanie — Wielkosci radiometryczne\n0,1 mW/cm² do 5 mW/cm² CMC 12 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/207 w oparciu o CIE 220:2016","search_en":"UV-A irradiance meters for non-destructive testing (NDT) Calibration — Radiometric quantities Internal procedure; Direct method; At permanent location (S) Radiometric quantities Internal procedure Direct method At permanent location (S) LW-1/IN/207 based on CIE 220:2016","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":22,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LW-1/IN/207 based on CIE 220:2016","methodology_de":"Kalibrierung — Radiometrische Größen","parameters_de":[{"name":"","range":"0,1 mW/cm² to 5 mW/cm²","cmc":"12 %"}],"reference_de":"LW-1/IN/207 auf Grundlage von CIE 220:2016","regulatory_area_de":"Radiometrische Größen","search_de":"UV-A-Bestrahlungsstärkemessgeräte für die zerstörungsfreie Prüfung (ZfP) Kalibrierung — Radiometrische Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Radiometrische Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/207 auf Grundlage von CIE 220:2016","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"UV-A-Bestrahlungsstärkemessgeräte für die zerstörungsfreie Prüfung (ZfP)","methodology_zh":"校准 — 辐射度量","parameters_zh":[{"name":"","range":"0,1 mW/cm² to 5 mW/cm²","cmc":"12 %"}],"reference_zh":"LW-1/IN/207 依据CIE 220:2016","regulatory_area_zh":"辐射度量","search_zh":"用于无损检测（NDT）的 UV-A 辐照度计 校准 — 辐射度量 内部程序；直接法；在固定地点 (S) 辐射度量 内部程序 直接法 在固定地点 (S) LW-1/IN/207 依据CIE 220:2016","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"用于无损检测（NDT）的 UV-A 辐照度计","methodology_cs":"Kalibrace — Radiometrické veličiny","parameters_cs":[{"name":"","range":"0,1 mW/cm² to 5 mW/cm²","cmc":"12 %"}],"reference_cs":"LW-1/IN/207 na základě CIE 220:2016","regulatory_area_cs":"Radiometrické veličiny","search_cs":"Měřiče ozáření UV-A pro nedestruktivní zkoušení (NDT) Kalibrace — Radiometrické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Radiometrické veličiny Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/207 na základě CIE 220:2016","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče ozáření UV-A pro nedestruktivní zkoušení (NDT)"},{"_id":"3c0fd1fc94cd37470f6a3100","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Luksomierze\ndo badań nieniszczących (NDT)","test_object_en":"Lux meters (illuminance meters)\nfor non-destructive testing (NDT)","methodology":"Wzorcowanie — Natężenie oświetlenia","methodology_en":"Calibration — Illuminance","parameters":[{"name":"","range":"20 lx do 5000 lx","cmc":"3,5 %"}],"parameters_en":[{"name":"","range":"20 lx to 5000 lx","cmc":"3,5 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Natężenie oświetlenia\n20 lx do 5000 lx CMC 3,5 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/207","norm_bases":["LW-1/IN/207"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Natężenie oświetlenia","regulatory_area_en":"Illuminance","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Luksomierze\ndo badań nieniszczących (NDT) Wzorcowanie — Natężenie oświetlenia\n20 lx do 5000 lx CMC 3,5 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/207 Luksomierze\ndo badan nieniszczacych (NDT) Wzorcowanie — Natezenie oswietlenia\n20 lx do 5000 lx CMC 3,5 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/207","search_en":"Lux meters (illuminance meters) for non-destructive testing (NDT) Calibration — Illuminance Internal procedure; Direct method; At permanent location (S) Illuminance Internal procedure Direct method At permanent location (S) LW-1/IN/207","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":23,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Beleuchtungsstärke","parameters_de":[{"name":"","range":"20 lx to 5000 lx","cmc":"3,5 %"}],"regulatory_area_de":"Beleuchtungsstärke","search_de":"Luxmeter für die zerstörungsfreie Prüfung (ZfP) Kalibrierung — Beleuchtungsstärke Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Beleuchtungsstärke Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/207","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Luxmeter\nfür die zerstörungsfreie Prüfung (ZfP)","methodology_zh":"校准 — 照度","parameters_zh":[{"name":"","range":"20 lx to 5000 lx","cmc":"3,5 %"}],"regulatory_area_zh":"照度","search_zh":"照度计 用于无损检测（NDT） 校准 — 照度 内部程序；直接法；在固定地点 (S) 照度 内部程序 直接法 在固定地点 (S) LW-1/IN/207","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"照度计\n用于无损检测（NDT）","methodology_cs":"Kalibrace — Intenzita osvětlení","parameters_cs":[{"name":"","range":"20 lx to 5000 lx","cmc":"3,5 %"}],"regulatory_area_cs":"Intenzita osvětlení","search_cs":"Luxmetry pro nedestruktivní zkoušení (NDT) Kalibrace — Intenzita osvětlení Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Intenzita osvětlení Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/207","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Luxmetry\npro nedestruktivní zkoušení (NDT)"},{"_id":"7848b560e4fc1477f77f1105","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne","test_object_en":"Mechanical manometers\nDigital manometers","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"- ciśnienie względne (czynnik gaz)","range":"-0,095 MPa do 0 MPa","cmc":"0,00005 MPa"},{"name":"- ciśnienie względne (czynnik gaz)","range":"0 MPa do 0,1 MPa","cmc":"0,00003 MPa"},{"name":"- ciśnienie względne (czynnik gaz)","range":"0,1 MPa do 3,5 MPa","cmc":"4,1 · 10⁻⁴ · p"},{"name":"- ciśnienie względne (czynnik ciecz)","range":"0,1 MPa do 1,4 MPa","cmc":"6,2 · 10⁻⁴ MPa"},{"name":"- ciśnienie względne (czynnik ciecz)","range":"1,4 MPa do 12 MPa","cmc":"4,1 · 10⁻⁴ · p"},{"name":"- ciśnienie względne (czynnik ciecz)","range":"12 MPa do 40 MPa","cmc":"2,1 · 10⁻⁴ · p"},{"name":"- ciśnienie względne (czynnik ciecz)","range":"40 MPa do 100 MPa","cmc":"3,5 · 10⁻⁴ · p"}],"parameters_en":[{"name":"gauge pressure (gas medium)","range":"-0,095 MPa to 0 MPa","cmc":"0,00005 MPa"},{"name":"gauge pressure (gas medium)","range":"0 MPa to 0,1 MPa","cmc":"0,00003 MPa"},{"name":"gauge pressure (gas medium)","range":"0,1 MPa to 3,5 MPa","cmc":"4,1 · 10⁻⁴ · p"},{"name":"gauge pressure (liquid medium)","range":"0,1 MPa to 1,4 MPa","cmc":"6,2 · 10⁻⁴ MPa"},{"name":"gauge pressure (liquid medium)","range":"1,4 MPa to 12 MPa","cmc":"4,1 · 10⁻⁴ · p"},{"name":"gauge pressure (liquid medium)","range":"12 MPa to 40 MPa","cmc":"2,1 · 10⁻⁴ · p"},{"name":"gauge pressure (liquid medium)","range":"40 MPa to 100 MPa","cmc":"3,5 · 10⁻⁴ · p"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne (czynnik gaz) -0,095 MPa do 0 MPa CMC 0,00005 MPa\n- ciśnienie względne (czynnik gaz) 0 MPa do 0,1 MPa CMC 0,00003 MPa\n- ciśnienie względne (czynnik gaz) 0,1 MPa do 3,5 MPa CMC 4,1 · 10⁻⁴ · p\n- ciśnienie względne (czynnik ciecz) 0,1 MPa do 1,4 MPa CMC 6,2 · 10⁻⁴ MPa\n- ciśnienie względne (czynnik ciecz) 1,4 MPa do 12 MPa CMC 4,1 · 10⁻⁴ · p\n- ciśnienie względne (czynnik ciecz) 12 MPa do 40 MPa CMC 2,1 · 10⁻⁴ · p\n- ciśnienie względne (czynnik ciecz) 40 MPa do 100 MPa CMC 3,5 · 10⁻⁴ · p\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/201 w oparciu o EURAMET Calibration Guide No. 17 Version 4.1 (09/2022)","norm_bases":["LW-1/IN/201","EURAMET Calibration Guide No. 17 Version 4.1 (09/2022)"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":"p – wielkość mierzona (MPa)","note_en":"p – measured value (MPa)","search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne (czynnik gaz) -0,095 MPa do 0 MPa CMC 0,00005 MPa\n- ciśnienie względne (czynnik gaz) 0 MPa do 0,1 MPa CMC 0,00003 MPa\n- ciśnienie względne (czynnik gaz) 0,1 MPa do 3,5 MPa CMC 4,1 · 10⁻⁴ · p\n- ciśnienie względne (czynnik ciecz) 0,1 MPa do 1,4 MPa CMC 6,2 · 10⁻⁴ MPa\n- ciśnienie względne (czynnik ciecz) 1,4 MPa do 12 MPa CMC 4,1 · 10⁻⁴ · p\n- ciśnienie względne (czynnik ciecz) 12 MPa do 40 MPa CMC 2,1 · 10⁻⁴ · p\n- ciśnienie względne (czynnik ciecz) 40 MPa do 100 MPa CMC 3,5 · 10⁻⁴ · p\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/201 w oparciu o EURAMET Calibration Guide No. 17 Version 4.1 (09/2022) Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne Wzorcowanie — Cisnienie\nZakres:\n- cisnienie wzgledne (czynnik gaz) -0,095 MPa do 0 MPa CMC 0,00005 MPa\n- cisnienie wzgledne (czynnik gaz) 0 MPa do 0,1 MPa CMC 0,00003 MPa\n- cisnienie wzgledne (czynnik gaz) 0,1 MPa do 3,5 MPa CMC 4,1 · 10⁻⁴ · p\n- cisnienie wzgledne (czynnik ciecz) 0,1 MPa do 1,4 MPa CMC 6,2 · 10⁻⁴ MPa\n- cisnienie wzgledne (czynnik ciecz) 1,4 MPa do 12 MPa CMC 4,1 · 10⁻⁴ · p\n- cisnienie wzgledne (czynnik ciecz) 12 MPa do 40 MPa CMC 2,1 · 10⁻⁴ · p\n- cisnienie wzgledne (czynnik ciecz) 40 MPa do 100 MPa CMC 3,5 · 10⁻⁴ · p\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/201 w oparciu o EURAMET Calibration Guide No. 17 Version 4.1 (09/2022)","search_en":"Mechanical manometers Digital manometers Calibration — Pressure Internal procedure; Direct method; At permanent location (S) Pressure Internal procedure Direct method At permanent location (S) gauge pressure (gas medium) gauge pressure (gas medium) gauge pressure (gas medium) gauge pressure (liquid medium) gauge pressure (liquid medium) gauge pressure (liquid medium) gauge pressure (liquid medium) LW-1/IN/201 based on EURAMET Calibration Guide No. 17 Version 4.1 (09/2022)","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":24,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LW-1/IN/201 based on EURAMET Calibration Guide No. 17 Version 4.1 (09/2022)","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"- Überdruck (Medium Gas)","range":"-0,095 MPa to 0 MPa","cmc":"0,00005 MPa"},{"name":"- Überdruck (Medium Gas)","range":"0 MPa to 0,1 MPa","cmc":"0,00003 MPa"},{"name":"- Überdruck (Medium Gas)","range":"0,1 MPa to 3,5 MPa","cmc":"4,1 · 10⁻⁴ · p"},{"name":"- Überdruck (Medium Flüssigkeit)","range":"0,1 MPa to 1,4 MPa","cmc":"6,2 · 10⁻⁴ MPa"},{"name":"- Überdruck (Medium Flüssigkeit)","range":"1,4 MPa to 12 MPa","cmc":"4,1 · 10⁻⁴ · p"},{"name":"- Überdruck (Medium Flüssigkeit)","range":"12 MPa to 40 MPa","cmc":"2,1 · 10⁻⁴ · p"},{"name":"- Überdruck (Medium Flüssigkeit)","range":"40 MPa to 100 MPa","cmc":"3,5 · 10⁻⁴ · p"}],"reference_de":"LW-1/IN/201 auf Grundlage von EURAMET Calibration Guide No. 17 Version 4.1 (09/2022)","regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte Kalibrierung — Druck Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Druck Internes Verfahren Direktes Verfahren Am festen Standort (S) - Überdruck (Medium Gas) - Überdruck (Medium Gas) - Überdruck (Medium Gas) - Überdruck (Medium Flüssigkeit) - Überdruck (Medium Flüssigkeit) - Überdruck (Medium Flüssigkeit) - Überdruck (Medium Flüssigkeit) LW-1/IN/201 auf Grundlage von EURAMET Calibration Guide No. 17 Version 4.1 (09/2022)","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"- 表压（介质为气体）","range":"-0,095 MPa to 0 MPa","cmc":"0,00005 MPa"},{"name":"- 表压（介质为气体）","range":"0 MPa to 0,1 MPa","cmc":"0,00003 MPa"},{"name":"- 表压（介质为气体）","range":"0,1 MPa to 3,5 MPa","cmc":"4,1 · 10⁻⁴ · p"},{"name":"- 表压（介质 液体）","range":"0,1 MPa to 1,4 MPa","cmc":"6,2 · 10⁻⁴ MPa"},{"name":"- 表压（介质 液体）","range":"1,4 MPa to 12 MPa","cmc":"4,1 · 10⁻⁴ · p"},{"name":"- 表压（介质 液体）","range":"12 MPa to 40 MPa","cmc":"2,1 · 10⁻⁴ · p"},{"name":"- 表压（介质 液体）","range":"40 MPa to 100 MPa","cmc":"3,5 · 10⁻⁴ · p"}],"reference_zh":"LW-1/IN/201 依据EURAMET Calibration Guide No. 17 Version 4.1 (09/2022)","regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 校准 — 压力 内部程序；直接法；在固定地点 (S) 压力 内部程序 直接法 在固定地点 (S) - 表压（介质为气体） - 表压（介质为气体） - 表压（介质为气体） - 表压（介质 液体） - 表压（介质 液体） - 表压（介质 液体） - 表压（介质 液体） LW-1/IN/201 依据EURAMET Calibration Guide No. 17 Version 4.1 (09/2022)","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"弹簧管压力表\n电子压力计","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"- přetlak (médium plyn)","range":"-0,095 MPa to 0 MPa","cmc":"0,00005 MPa"},{"name":"- přetlak (médium plyn)","range":"0 MPa to 0,1 MPa","cmc":"0,00003 MPa"},{"name":"- přetlak (médium plyn)","range":"0,1 MPa to 3,5 MPa","cmc":"4,1 · 10⁻⁴ · p"},{"name":"- přetlak (médium kapalina)","range":"0,1 MPa to 1,4 MPa","cmc":"6,2 · 10⁻⁴ MPa"},{"name":"- přetlak (médium kapalina)","range":"1,4 MPa to 12 MPa","cmc":"4,1 · 10⁻⁴ · p"},{"name":"- přetlak (médium kapalina)","range":"12 MPa to 40 MPa","cmc":"2,1 · 10⁻⁴ · p"},{"name":"- přetlak (médium kapalina)","range":"40 MPa to 100 MPa","cmc":"3,5 · 10⁻⁴ · p"}],"reference_cs":"LW-1/IN/201 na základě EURAMET Calibration Guide No. 17 Version 4.1 (09/2022)","regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry Kalibrace — Tlak Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Tlak Vnitřní postup Přímá metoda Ve stálé lokalitě (S) - přetlak (médium plyn) - přetlak (médium plyn) - přetlak (médium plyn) - přetlak (médium kapalina) - přetlak (médium kapalina) - přetlak (médium kapalina) - přetlak (médium kapalina) LW-1/IN/201 na základě EURAMET Calibration Guide No. 17 Version 4.1 (09/2022)","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry"},{"_id":"685a4d173fe5217c8897a22a","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Termometry elektryczne","test_object_en":"Electric thermometers","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-20 °C do 110 °C","cmc":"0,18 °C"}],"parameters_en":[{"name":"","range":"-20 °C to 110 °C","cmc":"0,18 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n-20 °C do 110 °C CMC 0,18 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LW-1/IN/206 w oparciu o DKD-R 5-1 (11/2023)","norm_bases":["LW-1/IN/206","DKD-R 5-1 (11/2023)"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Termometry elektryczne Wzorcowanie — Temperatura (termometria elektryczna)\n-20 °C do 110 °C CMC 0,18 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LW-1/IN/206 w oparciu o DKD-R 5-1 (11/2023) Termometry elektryczne Wzorcowanie — Temperatura (termometria elektryczna)\n-20 °C do 110 °C CMC 0,18 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LW-1/IN/206 w oparciu o DKD-R 5-1 (11/2023)","search_en":"Electric thermometers Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; At permanent location (S) and outside of it (P) Temperature (electrical thermometry) Internal procedure Direct method At permanent location (S) and outside of it (P) LW-1/IN/206 based on DKD-R 5-1 (11/2023)","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":25,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LW-1/IN/206 based on DKD-R 5-1 (11/2023)","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-20 °C to 110 °C","cmc":"0,18 °C"}],"reference_de":"LW-1/IN/206 auf Grundlage von DKD-R 5-1 (11/2023)","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LW-1/IN/206 auf Grundlage von DKD-R 5-1 (11/2023)","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Elektrische Thermometer","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-20 °C to 110 °C","cmc":"0,18 °C"}],"reference_zh":"LW-1/IN/206 依据DKD-R 5-1 (11/2023)","regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计 校准 — 温度（电测温） 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LW-1/IN/206 依据DKD-R 5-1 (11/2023)","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电测温度计","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-20 °C to 110 °C","cmc":"0,18 °C"}],"reference_cs":"LW-1/IN/206 na základě DKD-R 5-1 (11/2023)","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LW-1/IN/206 na základě DKD-R 5-1 (11/2023)","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Elektrické teploměry"},{"_id":"caf8b1e285e7b0347e05dad9","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Termometry elektryczne","test_object_en":"Electric thermometers","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"110 °C do 200 °C","cmc":"0,40 °C"},{"name":"","range":"200 °C do 550 °C","cmc":"0,65 °C"}],"parameters_en":[{"name":"","range":"110 °C to 200 °C","cmc":"0,40 °C"},{"name":"","range":"200 °C to 550 °C","cmc":"0,65 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n110 °C do 200 °C CMC 0,40 °C\n200 °C do 550 °C CMC 0,65 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/206 w oparciu o DKD-R 5-1 (11/2023)","norm_bases":["LW-1/IN/206","DKD-R 5-1 (11/2023)"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry elektryczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n110 °C do 200 °C CMC 0,40 °C\n200 °C do 550 °C CMC 0,65 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/206 w oparciu o DKD-R 5-1 (11/2023) Termometry elektryczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n110 °C do 200 °C CMC 0,40 °C\n200 °C do 550 °C CMC 0,65 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/206 w oparciu o DKD-R 5-1 (11/2023)","search_en":"Electric thermometers Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Direct method At permanent location (S) LW-1/IN/206 based on DKD-R 5-1 (11/2023)","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":26,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LW-1/IN/206 based on DKD-R 5-1 (11/2023)","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"110 °C to 200 °C","cmc":"0,40 °C"},{"name":"","range":"200 °C to 550 °C","cmc":"0,65 °C"}],"reference_de":"LW-1/IN/206 auf Grundlage von DKD-R 5-1 (11/2023)","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/206 auf Grundlage von DKD-R 5-1 (11/2023)","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"110 °C to 200 °C","cmc":"0,40 °C"},{"name":"","range":"200 °C to 550 °C","cmc":"0,65 °C"}],"reference_zh":"LW-1/IN/206 依据DKD-R 5-1 (11/2023)","regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计 校准 — 温度（电测温） 内部程序；直接法；在固定地点 (S) 温度（电测温） 内部程序 直接法 在固定地点 (S) LW-1/IN/206 依据DKD-R 5-1 (11/2023)","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"电测温度计","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"110 °C to 200 °C","cmc":"0,40 °C"},{"name":"","range":"200 °C to 550 °C","cmc":"0,65 °C"}],"reference_cs":"LW-1/IN/206 na základě DKD-R 5-1 (11/2023)","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/206 na základě DKD-R 5-1 (11/2023)","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry"},{"_id":"cbe793df92348d3ae0b5addc","lab_id":"6afad8058989a133b76447bd","country":"PL","accr_number":"AP 136","accr_body":"PCA","test_object":"Pirometry","test_object_en":"Pyrometers","methodology":"Wzorcowanie — Temperatura (termometria radiacyjna)","methodology_en":"Calibration — Temperature (radiation thermometry)","parameters":[{"name":"","range":"-23 °C do 100 °C","cmc":"0,9 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"1,5 °C"},{"name":"","range":"200 °C do 300 °C","cmc":"1,8 °C"},{"name":"","range":"300 °C do 400 °C","cmc":"2,1 °C"},{"name":"","range":"400 °C do 500 °C","cmc":"2,3 °C"},{"name":"","range":"500 °C do 550 °C","cmc":"2,6 °C"}],"parameters_en":[{"name":"","range":"-23 °C do 100 °C","cmc":"0,9 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"1,5 °C"},{"name":"","range":"200 °C do 300 °C","cmc":"1,8 °C"},{"name":"","range":"300 °C do 400 °C","cmc":"2,1 °C"},{"name":"","range":"400 °C do 500 °C","cmc":"2,3 °C"},{"name":"","range":"500 °C do 550 °C","cmc":"2,6 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-23 °C do 100 °C CMC 0,9 °C\n100 °C do 200 °C CMC 1,5 °C\n200 °C do 300 °C CMC 1,8 °C\n300 °C do 400 °C CMC 2,1 °C\n400 °C do 500 °C CMC 2,3 °C\n500 °C do 550 °C CMC 2,6 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LW-1/IN/206 w oparciu o MSL Technical Guide 22 (06.2009)","norm_bases":["LW-1/IN/206","MSL Technical Guide 22 (06.2009)"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria radiacyjna)","regulatory_area_en":"Temperature (radiation thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Pirometry Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-23 °C do 100 °C CMC 0,9 °C\n100 °C do 200 °C CMC 1,5 °C\n200 °C do 300 °C CMC 1,8 °C\n300 °C do 400 °C CMC 2,1 °C\n400 °C do 500 °C CMC 2,3 °C\n500 °C do 550 °C CMC 2,6 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LW-1/IN/206 w oparciu o MSL Technical Guide 22 (06.2009) Pirometry Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-23 °C do 100 °C CMC 0,9 °C\n100 °C do 200 °C CMC 1,5 °C\n200 °C do 300 °C CMC 1,8 °C\n300 °C do 400 °C CMC 2,1 °C\n400 °C do 500 °C CMC 2,3 °C\n500 °C do 550 °C CMC 2,6 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LW-1/IN/206 w oparciu o MSL Technical Guide 22 (06.2009)","search_en":"Pyrometers Calibration — Temperature (radiation thermometry) Internal procedure; Direct method; At permanent location (S) Temperature (radiation thermometry) Internal procedure Direct method At permanent location (S) LW-1/IN/206 based on MSL Technical Guide 22 (06.2009)","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":27,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LW-1/IN/206 based on MSL Technical Guide 22 (06.2009)","methodology_de":"Kalibrierung — Temperatur (Strahlungsthermometrie)","parameters_de":[{"name":"","range":"-23 °C do 100 °C","cmc":"0,9 °C"},{"name":"","range":"100 °C bis 200 °C","cmc":"1,5 °C"},{"name":"","range":"200 °C do 300 °C","cmc":"1,8 °C"},{"name":"","range":"300 °C do 400 °C","cmc":"2,1 °C"},{"name":"","range":"400 °C do 500 °C","cmc":"2,3 °C"},{"name":"","range":"500 °C do 550 °C","cmc":"2,6 °C"}],"reference_de":"LW-1/IN/206 auf Grundlage von MSL Technical Guide 22 (06.2009)","regulatory_area_de":"Temperatur (Strahlungsthermometrie)","search_de":"Pyrometer Kalibrierung — Temperatur (Strahlungsthermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Temperatur (Strahlungsthermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) LW-1/IN/206 auf Grundlage von MSL Technical Guide 22 (06.2009)","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Pyrometer","methodology_zh":"校准 — 温度（辐射测温）","parameters_zh":[{"name":"","range":"-23 °C do 100 °C","cmc":"0,9 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"1,5 °C"},{"name":"","range":"200 °C do 300 °C","cmc":"1,8 °C"},{"name":"","range":"300 °C do 400 °C","cmc":"2,1 °C"},{"name":"","range":"400 °C do 500 °C","cmc":"2,3 °C"},{"name":"","range":"500 °C do 550 °C","cmc":"2,6 °C"}],"reference_zh":"LW-1/IN/206 依据MSL Technical Guide 22 (06.2009)","regulatory_area_zh":"温度（辐射测温）","search_zh":"高温计 校准 — 温度（辐射测温） 内部程序；直接法；在固定地点 (S) 温度（辐射测温） 内部程序 直接法 在固定地点 (S) LW-1/IN/206 依据MSL Technical Guide 22 (06.2009)","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"高温计","methodology_cs":"Kalibrace — Teplota (radiační termometrie)","parameters_cs":[{"name":"","range":"-23 °C do 100 °C","cmc":"0,9 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"1,5 °C"},{"name":"","range":"200 °C do 300 °C","cmc":"1,8 °C"},{"name":"","range":"300 °C do 400 °C","cmc":"2,1 °C"},{"name":"","range":"400 °C do 500 °C","cmc":"2,3 °C"},{"name":"","range":"500 °C do 550 °C","cmc":"2,6 °C"}],"reference_cs":"LW-1/IN/206 na základě MSL Technical Guide 22 (06.2009)","regulatory_area_cs":"Teplota (radiační termometrie)","search_cs":"Pyrometry Kalibrace — Teplota (radiační termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Teplota (radiační termometrie) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LW-1/IN/206 na základě MSL Technical Guide 22 (06.2009)","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Pyrometry"}],"has_pdf":true}