{"lab":{"_id":"6ade8b7aff06824761708178","country":"PL","accr_number":"AP 134","imported_at":"2026-10-15T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Działkowa 22, 64-000 Kościan","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"08.04.2026","city":"Kościan","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 %. Niepewność pomiaru dla CMC wyrażona jest w jednostkach wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The uncertainty covered by the CMC is expressed in measurand units.","cycle_from":"08.06.2026","cycle_to":"08.06.2030","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"19.01","pl":"temperatura (termometria elektryczna)","en":"temperature (electrical thermometry)"},{"codes":"20.01","pl":"objętość","en":"volume"}],"has_en":true,"has_zh":false,"issue":{"no":"16","date":"08.06.2026"},"issue_date":"08.06.2026","issue_number":"16","lab_division":"Laboratorium Wzorcujące MERASERW JANOWICZ","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[16.6436339,52.0763434]},"map_coord":[52.0763434,16.6436339],"map_geo":"nominatim-street","methods_count":6,"name":"MERASERW JANOWICZ Maciej Janowicz","parse_date":"2026-10-15T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parse_status":"parsed","parse_version":1,"parsed_at":"2026-10-15T12:00:00.000Z","pdf_files":["AP_134.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: temperatura (termometria elektryczna), objętość. W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"meraserw janowicz maciej janowicz laboratorium wzorcujące meraserw janowicz ul. działkowa 22, 64-000 kościan laboratorium wzorcujące. wielkości mierzone: temperatura (termometria elektryczna), objętość. w stałej lokalizacji (s) i/lub poza nią (p). ap 134 ap134 laboratorium wzorcujące wzorcowanie kalibracja temperature (electrical thermometry) volume meraserw janowicz maciej janowicz laboratorium wzorcujace meraserw janowicz ul. dzialkowa 22, 64-000 koscian laboratorium wzorcujace. wielkosci mierzone: temperatura (termometria elektryczna), objetosc. w stalej lokalizacji (s) i/lub poza nia (p). ap 134 ap134 laboratorium wzorcujace wzorcowanie kalibracja temperature (electrical thermometry) volume","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20134,podmiot.html","source_pdf_sha256":"833e35b0ca96aac7528a37ab27050483064f7d39bb269da095bd216e2bf17e4e","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/10/15/55e8b611d43084f46a348fa703ae4fe1/AP%20134.pdf","status":"active","updated_at":"2026-10-15T12:00:00.000Z","valid_from":"09-06-2010","valid_until":"08-06-2030","website":"meraserw-j.com"},"methods":[{"_id":"61bb64aaa728d3fd6392cf63","lab_id":"6ade8b7aff06824761708178","country":"PL","accr_number":"AP 134","accr_body":"PCA","test_object":"Komory termostatyczne","test_object_en":"Thermostatic chambers","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-30 °C do 180 °C","cmc":"0,4 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 180 °C","cmc":"0,4 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n-30 °C do 180 °C CMC 0,4 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"MER-PT-02 w oparciu o EURAMET cg-20 v. 5.0","norm_bases":["MER-PT-02","EURAMET cg-20 v. 5.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Komory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\n-30 °C do 180 °C CMC 0,4 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) MER-PT-02 w oparciu o EURAMET cg-20 v. 5.0 Komory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\n-30 °C do 180 °C CMC 0,4 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) MER-PT-02 w oparciu o EURAMET cg-20 v. 5.0","search_en":"Thermostatic chambers Calibration — Temperature (electrical thermometry)\n-30 °C to 180 °C CMC 0,4 °C\nInternal procedure; Direct method; At permanent location (S) and outside of it (P) MER-PT-02 w oparciu o EURAMET cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fd60ef179dee7e4876c670d0","lab_id":"6ade8b7aff06824761708178","country":"PL","accr_number":"AP 134","accr_body":"PCA","test_object":"Termostaty cieczowe","test_object_en":"Liquid baths","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-30 °C do 180 °C","cmc":"0,3 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 180 °C","cmc":"0,3 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n-30 °C do 180 °C CMC 0,3 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"MER-PT-02","norm_bases":["MER-PT-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-30 °C do 180 °C CMC 0,3 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) MER-PT-02 Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-30 °C do 180 °C CMC 0,3 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) MER-PT-02","search_en":"Liquid baths Calibration — Temperature (electrical thermometry)\n-30 °C to 180 °C CMC 0,3 °C\nInternal procedure; Direct method; At permanent location (S) and outside of it (P) MER-PT-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4e3f79a8beb2b92b71663727","lab_id":"6ade8b7aff06824761708178","country":"PL","accr_number":"AP 134","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)","test_object_en":"Electrical thermometers (including electronic)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-30 °C do 180 °C","cmc":"0,06 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 180 °C","cmc":"0,06 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n-30 °C do 180 °C CMC 0,06 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"MER-PT-03","norm_bases":["MER-PT-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne) Wzorcowanie — Temperatura (termometria elektryczna)\n-30 °C do 180 °C CMC 0,06 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) MER-PT-03 Termometry elektryczne (w tym elektroniczne) Wzorcowanie — Temperatura (termometria elektryczna)\n-30 °C do 180 °C CMC 0,06 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) MER-PT-03","search_en":"Electrical thermometers (including electronic) Calibration — Temperature (electrical thermometry)\n-30 °C to 180 °C CMC 0,06 °C\nInternal procedure; At permanent location (S) MER-PT-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"857ce539916c1b6d12f82769","lab_id":"6ade8b7aff06824761708178","country":"PL","accr_number":"AP 134","accr_body":"PCA","test_object":"Pipety tłokowe\nBiurety tłokowe\nDozowniki","test_object_en":"Piston pipettes\nPiston burettes\nDispensers","methodology":"Wzorcowanie — Objętość","methodology_en":"Calibration — Volume","parameters":[{"name":"","range":"0,1 μl do 2,5 μl","cmc":"0,018 μl"},{"name":"","range":"2,5 μl do 20 μl","cmc":"0,033 μl"},{"name":"","range":"20 μl do 200 μl","cmc":"0,29 μl"},{"name":"","range":"200 μl do 1 000 μl","cmc":"1,7 μl"},{"name":"","range":"1 000 μl do 5 000 μl","cmc":"8,7 μl"},{"name":"","range":"5 000 μl do 10 000 μl","cmc":"14 μl"},{"name":"","range":"10 000 μl do 20 000 μl","cmc":"33 μl"}],"parameters_en":[{"name":"","range":"0,1 μl to 2,5 μl","cmc":"0,018 μl"},{"name":"","range":"2,5 μl to 20 μl","cmc":"0,033 μl"},{"name":"","range":"20 μl to 200 μl","cmc":"0,29 μl"},{"name":"","range":"200 μl to 1 000 μl","cmc":"1,7 μl"},{"name":"","range":"1 000 μl to 5 000 μl","cmc":"8,7 μl"},{"name":"","range":"5 000 μl to 10 000 μl","cmc":"14 μl"},{"name":"","range":"10 000 μl to 20 000 μl","cmc":"33 μl"}],"technique":"Procedura wewnętrzna; Metoda grawimetryczna; W stałej lokalizacji (S)","technique_en":"Internal procedure; Gravimetric method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda grawimetryczna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Gravimetric method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Objętość\nZakres:\n0,1 μl do 2,5 μl CMC 0,018 μl\n2,5 μl do 20 μl CMC 0,033 μl\n20 μl do 200 μl CMC 0,29 μl\n200 μl do 1 000 μl CMC 1,7 μl\n1 000 μl do 5 000 μl CMC 8,7 μl\n5 000 μl do 10 000 μl CMC 14 μl\n10 000 μl do 20 000 μl CMC 33 μl\nProcedura wewnętrzna; Metoda grawimetryczna; W stałej lokalizacji (S)","reference":"MER-PT-01 w oparciu o PN-EN ISO 8655-6:2022","norm_bases":["MER-PT-01","PN-EN ISO 8655-6:2022"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Objętość","regulatory_area_en":"Volume","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Pipety tłokowe\nBiurety tłokowe\nDozowniki Wzorcowanie — Objętość\nZakres:\n0,1 μl do 2,5 μl CMC 0,018 μl\n2,5 μl do 20 μl CMC 0,033 μl\n20 μl do 200 μl CMC 0,29 μl\n200 μl do 1 000 μl CMC 1,7 μl\n1 000 μl do 5 000 μl CMC 8,7 μl\n5 000 μl do 10 000 μl CMC 14 μl\n10 000 μl do 20 000 μl CMC 33 μl\nProcedura wewnętrzna; Metoda grawimetryczna; W stałej lokalizacji (S) MER-PT-01 w oparciu o PN-EN ISO 8655-6:2022 Pipety tlokowe\nBiurety tlokowe\nDozowniki Wzorcowanie — Objetosc\nZakres:\n0,1 μl do 2,5 μl CMC 0,018 μl\n2,5 μl do 20 μl CMC 0,033 μl\n20 μl do 200 μl CMC 0,29 μl\n200 μl do 1 000 μl CMC 1,7 μl\n1 000 μl do 5 000 μl CMC 8,7 μl\n5 000 μl do 10 000 μl CMC 14 μl\n10 000 μl do 20 000 μl CMC 33 μl\nProcedura wewnetrzna; Metoda grawimetryczna; W stalej lokalizacji (S) MER-PT-01 w oparciu o PN-EN ISO 8655-6:2022","search_en":"Piston pipettes\nPiston burettes\nDispensers Calibration — Volume\nScope:\n0,1 μl to 2,5 μl CMC 0,018 μl\n2,5 μl to 20 μl CMC 0,033 μl\n20 μl to 200 μl CMC 0,29 μl\n200 μl to 1 000 μl CMC 1,7 μl\n1 000 μl to 5 000 μl CMC 8,7 μl\n5 000 μl to 10 000 μl CMC 14 μl\n10 000 μl to 20 000 μl CMC 33 μl\nInternal procedure; Gravimetric method; At permanent location (S) MER-PT-01 w oparciu o PN-EN ISO 8655-6:2022","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7ee06de0852d5a63c97ea55a","lab_id":"6ade8b7aff06824761708178","country":"PL","accr_number":"AP 134","accr_body":"PCA","test_object":"Biurety tłokowe\nDozowniki","test_object_en":"Piston burettes\nDispensers","methodology":"Wzorcowanie — Objętość","methodology_en":"Calibration — Volume","parameters":[{"name":"","range":"20 000 μl do 50 000 μl","cmc":"30 μl"}],"parameters_en":[{"name":"","range":"20 000 μl to 50 000 μl","cmc":"30 μl"}],"technique":"Procedura wewnętrzna; Metoda grawimetryczna; W stałej lokalizacji (S)","technique_en":"Internal procedure; Gravimetric method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda grawimetryczna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Gravimetric method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Objętość\n20 000 μl do 50 000 μl CMC 30 μl\nProcedura wewnętrzna; Metoda grawimetryczna; W stałej lokalizacji (S)","reference":"MER-PT-01 w oparciu o PN-EN ISO 8655-6:2022","norm_bases":["MER-PT-01","PN-EN ISO 8655-6:2022"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Objętość","regulatory_area_en":"Volume","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Biurety tłokowe\nDozowniki Wzorcowanie — Objętość\n20 000 μl do 50 000 μl CMC 30 μl\nProcedura wewnętrzna; Metoda grawimetryczna; W stałej lokalizacji (S) MER-PT-01 w oparciu o PN-EN ISO 8655-6:2022 Biurety tlokowe\nDozowniki Wzorcowanie — Objetosc\n20 000 μl do 50 000 μl CMC 30 μl\nProcedura wewnetrzna; Metoda grawimetryczna; W stalej lokalizacji (S) MER-PT-01 w oparciu o PN-EN ISO 8655-6:2022","search_en":"Piston burettes\nDispensers Calibration — Volume\n20 000 μl to 50 000 μl CMC 30 μl\nInternal procedure; Gravimetric method; At permanent location (S) MER-PT-01 w oparciu o PN-EN ISO 8655-6:2022","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"acca7608a63bf66b929e26e4","lab_id":"6ade8b7aff06824761708178","country":"PL","accr_number":"AP 134","accr_body":"PCA","test_object":"Dozowniki","test_object_en":"Dispensers","methodology":"Wzorcowanie — Objętość","methodology_en":"Calibration — Volume","parameters":[{"name":"","range":"50 000 μl do 100 000 μl","cmc":"580 μl"}],"parameters_en":[{"name":"","range":"50 000 μl to 100 000 μl","cmc":"580 μl"}],"technique":"Procedura wewnętrzna; Metoda grawimetryczna; W stałej lokalizacji (S)","technique_en":"Internal procedure; Gravimetric method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda grawimetryczna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Gravimetric method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Objętość\n50 000 μl do 100 000 μl CMC 580 μl\nProcedura wewnętrzna; Metoda grawimetryczna; W stałej lokalizacji (S)","reference":"MER-PT-01 w oparciu o PN-EN ISO 8655-6:2022","norm_bases":["MER-PT-01","PN-EN ISO 8655-6:2022"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Objętość","regulatory_area_en":"Volume","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Dozowniki Wzorcowanie — Objętość\n50 000 μl do 100 000 μl CMC 580 μl\nProcedura wewnętrzna; Metoda grawimetryczna; W stałej lokalizacji (S) MER-PT-01 w oparciu o PN-EN ISO 8655-6:2022 Dozowniki Wzorcowanie — Objetosc\n50 000 μl do 100 000 μl CMC 580 μl\nProcedura wewnetrzna; Metoda grawimetryczna; W stalej lokalizacji (S) MER-PT-01 w oparciu o PN-EN ISO 8655-6:2022","search_en":"Dispensers Calibration — Volume\n50 000 μl to 100 000 μl CMC 580 μl\nInternal procedure; Gravimetric method; At permanent location (S) MER-PT-01 w oparciu o PN-EN ISO 8655-6:2022","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}