{"lab":{"_id":"6ade8b78ff06824761708171","country":"PL","accr_number":"AP 117","imported_at":"2026-10-15T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"Aleja Pokoju 82, 31-564 Kraków","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"10.05.2019","city":"Kraków","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 %. Wartość wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The value expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand.","cycle_from":"06.06.2024","cycle_to":"13.07.2028","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"3.03","pl":"ułamek molowy (analiza gazów)","en":"mole fraction (gas analysis)"}],"has_en":true,"has_zh":false,"issue":{"no":"12","date":"23.05.2025"},"issue_date":"23.05.2025","issue_number":"12","lab_division":"MESSERVICE Laboratorium","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[20.013999,50.0702152]},"map_coord":[50.0702152,20.013999],"map_geo":"nominatim-street","methods_count":1,"name":"MESSERVICE Henryk Michalczewski","parse_date":"2026-10-15T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parse_status":"parsed","parse_version":1,"parsed_at":"2026-10-15T12:00:00.000Z","pdf_files":["AP_117.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: ułamek molowy (analiza gazów). W stałej lokalizacji (S).","search_text":"messervice henryk michalczewski messervice laboratorium aleja pokoju 82, 31-564 kraków laboratorium wzorcujące. wielkości mierzone: ułamek molowy (analiza gazów). w stałej lokalizacji (s). ap 117 ap117 laboratorium wzorcujące wzorcowanie kalibracja mole fraction (gas analysis) messervice henryk michalczewski messervice laboratorium aleja pokoju 82, 31-564 krakow laboratorium wzorcujace. wielkosci mierzone: ulamek molowy (analiza gazow). w stalej lokalizacji (s). ap 117 ap117 laboratorium wzorcujace wzorcowanie kalibracja mole fraction (gas analysis)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20117,podmiot.html","source_pdf_sha256":"a206822f78ef95da631b8f18506dd057777106a39722e457966b6eee2ab3ce76","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/10/15/0085bc067e54a8992a17f2b74a90e03b/AP%20117.pdf","status":"active","updated_at":"2026-10-15T12:00:00.000Z","valid_from":"14-07-2008","valid_until":"13-07-2028","website":"www.messervice.pl"},"methods":[{"_id":"717e58c6aafd8513f739681b","lab_id":"6ade8b78ff06824761708171","country":"PL","accr_number":"AP 117","accr_body":"PCA","test_object":"Analizatory spalin samochodowych","test_object_en":"Automotive exhaust gas analysers","methodology":"Wzorcowanie — Ułamek molowy (analiza gazów)","methodology_en":"Calibration — Mole fraction (gas analysis)","parameters":[{"name":"CO","range":"4 mmol/mol do 6 mmol/mol","cmc":"4,0 %"},{"name":"CO","range":"29 mmol/mol do 43 mmol/mol","cmc":"2,0 %"},{"name":"CO2","range":"48 mmol/mol do 71 mmol/mol","cmc":"2,0 %"},{"name":"CO2","range":"111 mmol/mol do 166 mmol/mol","cmc":"2,0 %"},{"name":"C3H8","range":"0,16 mmol/mol do 0,24 mmol/mol","cmc":"3,0 %"},{"name":"C3H8","range":"1,6 mmol/mol do 2,4 mmol/mol","cmc":"3,0 %"}],"parameters_en":[{"name":"CO","range":"4 mmol/mol to 6 mmol/mol","cmc":"4,0 %"},{"name":"CO","range":"29 mmol/mol to 43 mmol/mol","cmc":"2,0 %"},{"name":"CO2","range":"48 mmol/mol to 71 mmol/mol","cmc":"2,0 %"},{"name":"CO2","range":"111 mmol/mol to 166 mmol/mol","cmc":"2,0 %"},{"name":"C3H8","range":"0,16 mmol/mol to 0,24 mmol/mol","cmc":"3,0 %"},{"name":"C3H8","range":"1,6 mmol/mol to 2,4 mmol/mol","cmc":"3,0 %"}],"technique":"Procedura wewnętrzna; Wzorcowanie z zastosowaniem certyfikowanych materiałów odniesienia (CRM); W stałej lokalizacji (S)","technique_en":"Internal procedure; Calibration using certified reference materials (CRM); At permanent location (S)","techniques":["Procedura wewnętrzna","Wzorcowanie z zastosowaniem certyfikowanych materiałów odniesienia (CRM)","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Calibration using certified reference materials (CRM)","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ułamek molowy (analiza gazów)\nZakres:\nCO 4 mmol/mol do 6 mmol/mol CMC 4,0 %\nCO 29 mmol/mol do 43 mmol/mol CMC 2,0 %\nCO2 48 mmol/mol do 71 mmol/mol CMC 2,0 %\nCO2 111 mmol/mol do 166 mmol/mol CMC 2,0 %\nC3H8 0,16 mmol/mol do 0,24 mmol/mol CMC 3,0 %\nC3H8 1,6 mmol/mol do 2,4 mmol/mol CMC 3,0 %\nProcedura wewnętrzna; Wzorcowanie z zastosowaniem certyfikowanych materiałów odniesienia (CRM); W stałej lokalizacji (S)","reference":"P-WZ","norm_bases":["P-WZ"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ułamek molowy (analiza gazów)","regulatory_area_en":"Mole fraction (gas analysis)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Analizatory spalin samochodowych Wzorcowanie — Ułamek molowy (analiza gazów)\nZakres:\nCO 4 mmol/mol do 6 mmol/mol CMC 4,0 %\nCO 29 mmol/mol do 43 mmol/mol CMC 2,0 %\nCO2 48 mmol/mol do 71 mmol/mol CMC 2,0 %\nCO2 111 mmol/mol do 166 mmol/mol CMC 2,0 %\nC3H8 0,16 mmol/mol do 0,24 mmol/mol CMC 3,0 %\nC3H8 1,6 mmol/mol do 2,4 mmol/mol CMC 3,0 %\nProcedura wewnętrzna; Wzorcowanie z zastosowaniem certyfikowanych materiałów odniesienia (CRM); W stałej lokalizacji (S) P-WZ Analizatory spalin samochodowych Wzorcowanie — Ulamek molowy (analiza gazow)\nZakres:\nCO 4 mmol/mol do 6 mmol/mol CMC 4,0 %\nCO 29 mmol/mol do 43 mmol/mol CMC 2,0 %\nCO2 48 mmol/mol do 71 mmol/mol CMC 2,0 %\nCO2 111 mmol/mol do 166 mmol/mol CMC 2,0 %\nC3H8 0,16 mmol/mol do 0,24 mmol/mol CMC 3,0 %\nC3H8 1,6 mmol/mol do 2,4 mmol/mol CMC 3,0 %\nProcedura wewnetrzna; Wzorcowanie z zastosowaniem certyfikowanych materialow odniesienia (CRM); W stalej lokalizacji (S) P-WZ","search_en":"Automotive exhaust gas analysers Calibration — Mole fraction (gas analysis)\nScope:\nCO 4 mmol/mol to 6 mmol/mol CMC 4,0 %\nCO 29 mmol/mol to 43 mmol/mol CMC 2,0 %\nCO2 48 mmol/mol to 71 mmol/mol CMC 2,0 %\nCO2 111 mmol/mol to 166 mmol/mol CMC 2,0 %\nC3H8 0,16 mmol/mol to 0,24 mmol/mol CMC 3,0 %\nC3H8 1,6 mmol/mol to 2,4 mmol/mol CMC 3,0 %\nInternal procedure; Calibration using certified reference materials (CRM); At permanent location (S) P-WZ","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}